PRODUCT DATASHEET

RAY78-50JFLA

7/8" RADIAFLEX® RAY Cable, A-series

‡ RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines


and large building complexes and is the solution for any application in confined areas.
‡ Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be
radiated into the surrounding environment. Conversely, a signal transmitted near the cable will
couple into the slots and be carried along the cable length.
‡ RADIAFLEX® is used for both one-way and two-way communication systems and because of its
broadband capability, a single radiating cable can handle multiple communication systems
simultaneously.
‡ This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a
smooth copper outer conductor which offers a superior electrical performance together with
good bending properties.

FEATURES / BENEFITS
Broadband from 30 MHz to 1000 MHz
Optimized for high frequencies and digital transmission
Low coupling loss variation RAY cable, A-series
For tunnel applications

Technical Features
GENERAL SPECIFICATIONS
Size 7/8"
ELECTRICAL SPECIFICATIONS
Max. Operating Frequency MHz 1000
Cable Type RAY
Impedance Ohm 50 +/- 2
Velocity % 89
Capacitance pF/m (pF/ft) 75 (22.9)
Inductance µH/m (µH/ft) 0.1875 (0.057)
DC-resistance inner conductor ȍkm ȍft) 1.74 (0.53)
DC-resistance outer conductor ȍkm ȍft) 2.52 (0.77)
Stop bands MHz 240-300, 500-590, 750-860
MECHANICAL SPECIFICATIONS
Jacket JFL
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier
Jacket Description
tape above outer conductor for lowest cable loss
Slot Design Groups of slope slots at short intervals
Inner Conductor Material Copper Tube
Outer Conductor Material Overlapping Copper Foil
Diameter Inner Conductor mm (in) 9.3 (0.37)
Diameter Outer Conductor mm (in) 23.8 (0.94)
Diameter over Jacket mm (in) 28.5 (1.12)
Minimum Bending Radius, Single Bend mm (in) 350 (13.8)
Cable Weight kg/m (lb/ft) 0.55 (0.37)
Tensile Force N (lb) 2300 (507)
Indication of Slot Alignment Bulge atop slots
Recommended Clamp Spacing m (ft) 0.9 (3)
Minimum Distance to Wall mm (in) 80 (3.15)
TEMPERATURE SPECIFICATIONS
Storage Temperature °C(°F) -70 to 85 (-94 to 185 )
Installation Temperature °C(°F) -25 to 60 (-13 to 140 )
Operation Temperature °C(°F) -40 to 85 (-40 to 185 )

RAY78-50JFLA REV: REV DATE: 2015/04/24 www.rfsworld.com

All information contained in the present datasheet is subject to confirmation at time of ordering Page 1 of 2
PRODUCT DATASHEET
RAY78-50JFLA

7/8" RADIAFLEX® RAY Cable, A-series

ATTENUATION AND POWER RATING


Frequency Longitudinal Coupling Loss TESTING AND ENVIRONMENTAL
loss Jacket Testing Methods Test methods for fire behaviour of cable :
MHz dB/100m 50%, dB 95%, dB IEC 60754-1/-2 smoke emission: halogen free, non corrosive
(dB/100ft) IEC 61034 low smoke
IEC 60332-1 flame retardant
75 1,04 (0,32) 53 (57) 62 (66)
IEC 60332-3-24 fire retardant
150 1,48 (0,45) 58 (62) 69 (73) UL1666, ASTM E 662, NES711 and NES713
450 2,67 (0,81) 60 (62) 67 (69)
870 5,41 (1,65) 54 (56) 63 (65)
900 5,70 (1,74) 54 (56) 61 (63)
960 6,46 (1,97) 54 (56) 60 (62)

External Document Links Notes


Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space
method according to IEC 61196-4.
Coupling loss values are measured with a radial (below 300 MHz) or orthogonal (above 300 MHz) orientated
dipole antenna.
The coupling loss values given in brackets are average values of all three spatial orientations (radial, parallel
and orthogonal) of dipole antenna.
Coupling loss values are given with a tolerance of +5 dB and longitudinal loss values with a tolerance of +5%.
Note: Measured values below nominal are better. They are not limited by any tolerance-range.
In case of a conflict of operational and stop band, please contact RFS for further assistance.
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based
on free space method.
;

RAY78-50JFLA REV: REV DATE: 2015/04/24 www.rfsworld.com

All information contained in the present datasheet is subject to confirmation at time of ordering Page 2 of 2