C:/Users/ARNOLD/Desktop/mr and Mrs Castillo/staad/mr and Mrs Castillo - Anl
C:/Users/ARNOLD/Desktop/mr and Mrs Castillo/staad/mr and Mrs Castillo - Anl
PAGE NO. 1
****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 22.06.00.138 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= JUL 6, 2021 *
* Time= 20:12:54 *
* *
* Licensed to: only @ ::LAVTeam:: (R) *
****************************************************
1. STAAD SPACE
INPUT FILE: C:\Users\ARNOLD\Desktop\mr and mrs castillo\staad\mr and mrs castillo.STD
2. START JOB INFORMATION
3. ENGINEER DATE 21-JUN-21
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 3.5 0 0; 3 5.5 0 0; 4 8.5 0 0; 5 11.5 0 0; 6 0 0 3; 7 5.5 0 3
9. 8 8.5 0 3; 9 11.5 0 2; 10 8.5 0 2; 11 0 0 6; 12 3.5 0 6; 13 5.5 0 6
10. 14 11.5 0 6; 15 8.5 0 6; 16 5.5 0 8.5; 17 11.5 0 8.5; 18 3.5 0 8.5; 19 0 1.2 0
11. 20 3.5 1.2 0; 21 5.5 1.2 0; 22 8.5 1.2 0; 23 11.5 1.2 0; 24 0 1.2 3
12. 25 5.5 1.2 3; 26 8.5 1.2 3; 27 11.5 1.2 2; 28 8.5 1.2 2; 29 0 1.2 6
13. 30 3.5 1.2 6; 31 5.5 1.2 6; 32 11.5 1.2 6; 33 8.5 1.2 6; 34 5.5 1.2 8.5
14. 35 11.5 1.2 8.5; 36 3.5 1.2 8.5; 37 0 4.2 0; 38 3.5 4.2 0; 39 5.5 4.2 0
15. 40 8.5 4.2 0; 41 11.5 4.2 0; 42 0 4.2 3; 43 5.5 4.2 3; 44 8.5 4.2 3
16. 45 11.5 4.2 2; 46 8.5 4.2 2; 47 0 4.2 6; 48 3.5 4.2 6; 49 5.5 4.2 6
17. 50 11.5 4.2 6; 51 8.5 4.2 6; 52 5.5 4.2 8.5; 53 11.5 4.2 8.5; 54 3.5 4.2 8.5
18. 55 0 7.2 0; 56 3.5 7.2 0; 57 5.5 7.2 0; 58 8.5 7.2 0; 59 11.5 7.2 0
19. 60 0 7.2 3; 61 5.5 7.2 3; 62 11.5 7.2 2; 63 8.5 7.2 2; 64 0 7.2 6
20. 65 3.5 7.2 6; 66 5.5 7.2 6; 67 11.5 7.2 6; 68 8.5 7.2 6; 69 5.5 7.2 8.5
21. 70 3.5 7.2 8.5; 71 3.5 1.2 3; 72 3.5 4.2 3; 73 3.5 7.2 3
22. MEMBER INCIDENCES
23. 1 1 19; 2 19 37; 3 37 55; 4 2 20; 5 20 38; 6 38 56; 7 3 21; 8 21 39; 9 39 57
24. 10 4 22; 11 22 40; 12 40 58; 13 5 23; 14 23 41; 15 41 59; 16 6 24; 17 24 42
25. 18 42 60; 19 7 25; 20 25 43; 21 43 61; 22 8 26; 23 26 44; 24 9 27; 25 27 45
26. 26 45 62; 27 10 28; 28 28 46; 29 46 63; 30 11 29; 31 29 47; 32 47 64; 33 12 30
27. 34 30 48; 35 48 65; 36 13 31; 37 31 49; 38 49 66; 39 14 32; 40 32 50; 41 50 67
28. 42 15 33; 43 33 51; 44 51 68; 45 16 34; 46 34 52; 47 52 69; 48 17 35; 49 35 53
29. 50 18 36; 51 36 54; 52 54 70; 53 19 20; 54 20 21; 55 21 22; 56 22 23; 57 24 71
30. 58 25 26; 59 28 27; 60 29 30; 61 30 31; 62 31 33; 63 33 32; 64 36 34; 65 34 35
31. 66 19 24; 67 24 29; 68 20 71; 69 30 36; 70 21 25; 71 25 31; 72 31 34; 73 22 28
32. 74 28 26; 75 26 33; 76 23 27; 77 27 32; 78 32 35; 79 71 25; 80 71 30; 81 37 42
33. 82 42 47; 83 38 72; 84 48 54; 85 39 43; 86 43 49; 87 49 52; 88 40 46; 89 46 44
34. 90 44 51; 91 41 45; 92 45 50; 93 50 53; 94 37 38; 95 38 39; 96 39 40; 97 40 41
35. 98 42 72; 99 43 44; 100 46 45; 101 47 48; 102 48 49; 103 49 51; 104 51 50
36. 105 54 52; 106 52 53; 107 72 48; 108 72 43; 109 55 60; 110 60 64; 111 56 73
37. 112 65 70; 113 57 61; 114 61 66; 115 66 69; 116 58 63; 117 63 68; 118 59 62
38. 119 62 67; 120 55 56; 121 56 57; 122 57 58; 123 58 59; 124 60 73; 125 63 62
39. 126 64 65; 127 65 66; 128 66 68; 129 68 67; 130 70 69; 131 73 65; 132 73 61
40. START GROUP DEFINITION
41. FLOOR
42. _2NDFLOOR2WAY 81 TO 92 94 TO 105 107 108
43. _2NDFLR-ROOF2WAY 87 93 103 104 106
44. _3RDROOF2WAY 109 TO 132
45. END GROUP DEFINITION
46. DEFINE MATERIAL START
47. ISOTROPIC CONCRETE
48. E 2.17185E+07
49. POISSON 0.17
50. DENSITY 23.5616
51. ALPHA 1E-05
52. DAMP 0.05
53. G 9.28139E+06
54. TYPE CONCRETE
55. STRENGTH FCU 27579
56. END DEFINE MATERIAL
57. MEMBER PROPERTY
58. 1 TO 52 PRIS YD 0.3 ZD 0.3
59. 53 TO 80 109 TO 132 PRIS YD 0.2 ZD 0.3
60. 81 TO 108 PRIS YD 0.3 ZD 0.25
61. CONSTANTS
62. MATERIAL CONCRETE ALL
63. SUPPORTS
64. 1 TO 18 FIXED
65. DEFINE REFERENCE LOADS
66. LOAD R1 LOADTYPE DEAD TITLE REF LOAD CASE 1
67. SELFWEIGHT Y 1
68. FLOOR LOAD
69. _2NDFLOOR2WAY FLOAD 3.7 GY
70. _2NDFLR-ROOF2WAY FLOAD 0.71 GY
71. _3RDROOF2WAY FLOAD 0.71 GY
72. END DEFINE REFERENCE LOADS
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
FLOOR DIAPHRAGM
************************************************************************************
NO. TYPE FL. LEVEL FL. WT CENTRE OF MASS MASTER JOINT NO.
X Z
************************************************************************************
82. R1 1.0
83. LOAD 1 LOADTYPE SEISMIC TITLE EX
84. UBC LOAD X 1 DEC 1 ACC 0.05
85. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
1 1.20 OK OK
2 4.20 OK OK
3 7.20 OK OK
***********************************************************
* *
* X DIRECTION : Ta = 0.321 Tb = 0.289 Tuser = 0.000 *
* T = 0.289, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1176 x 950.39 = 111.81 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
86. CHANGE
87. LOAD 2 LOADTYPE SEISMIC TITLE EZ
88. UBC LOAD Z 1 DEC 1 ACC 0.05
89. PERFORM ANALYSIS
***********************************************************
* *
* Z DIRECTION : Ta = 0.321 Tb = 0.286 Tuser = 0.000 *
* T = 0.286, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1176 x 950.39 = 111.81 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
90. CHANGE
91. LOAD 3 LOADTYPE DEAD TITLE DL
92. REFERENCE LOAD
93. R1 -1.0
94. LOAD 4 LOADTYPE LIVE TITLE LL
95. FLOOR LOAD
96. _2NDFLOOR2WAY FLOAD -1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
************************************************************
************************************************************
147. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) Bentley Systems, Inc. *
* http://www.bentley.com *
************************************************************