DIgSILENT PowerFactory

Relay model description

Alstom LFAA

Version 001
DIgSILENT GmbH

Heinrich-Hertz-Str. 9
72810 - Gomaringen
Germany

T: +49 7072 9168 00


F: +49 7072 9168 88

http://www.digsilent.de
[email protected]

Format rev. 1, Copyright ©2012, DIgSILENT GmbH. Copyright of this document belongs to DIgSILENT
GmbH. No part of this document may be reproduced, copied, or transmitted in any form, by any means
electronic or mechanical, without the prior written permission of DIgSILENT GmbH.

Alstom LFAA Version: 001 1


List of Figures

Contents

List of Figures 2

1 Model information 3

2 General description 3

3 Supported features 4

3.1 Measurement and acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3.1.1 Available Units and input signals . . . . . . . . . . . . . . . . . . . . . . . 4

3.1.2 Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3.1.3 Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3.2 Main Relay protective elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.2.1 Available Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.2.2 Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.2.3 Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.3 Output logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.3.1 Available Units and Signals . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.3.2 Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.3.3 Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4 Main relay scheme 7

5 Features not supported 9

6 References 10

7 Change Log 11

List of Figures

4.1 Alstom LFAA relay connection scheme . . . . . . . . . . . . . . . . . . . . . . . 7

4.2 Alstom LFAA ”Reclosing link” interconnection scheme . . . . . . . . . . . . . . . 8

Alstom LFAA Version: 001 2


2 General description

1 Model information

Manufacturer Alstom

Model LFAA

Variants The Alstom LFAA PowerFactory relay model can be used to simulate the different
firmware versions of the Alstom LFAA 101 recloser relay. However please consider that the
model has been implemented with a reduced set of the features available in the relays.

Minimum requirements PowerFactory V 13.2

2 General description

The LFAA auto-reclose relay provides facilities for single or two shot reclosures of one or two
circuit breakers following their tripping for a fault on an overhead line. The reclosures can be
selected to be either high speed single-phase, or high speed or delayed three-phase. When
three-phase reclosure is desired the equipment will convert any single or two-phase tripping into
three-phase tripping before initiating the reclosure. Two models are available: the LFAA 101, for
application to feeders switched by a single circuit breaker, and the LFAA 102, for application to
feeders switched by two circuit breakers.

The Alstom LFAA PowerFactory relay model consist of a monolithic scheme. An unique relay
model version is available.

The relay model consists of the measurement and acquisition units, the reclosing elements, the
overcurrent element and the output logic. A single circuit breaker can be controlled so only the
Alstom LFAA 101 can be modeled.

The model has been conceived to be used together with at least one protective relay that
trips the breaker. The trip signal of the protective relay must be sent to an instance of the
Alstom LFAA relay model to start the reclosing sequence. The Alstom LFAA relay and the other
protective relay must be linked together by an external scheme. Inside the Alstom LFAA relay
model the ”Reclosing link” generic interconnection scheme can be found and can be used at this
purpose.

The model implementation has been based on the information available in the relay manual [1].

Alstom LFAA Version: 001 3


3 Supported features

3 Supported features

3.1 Measurement and acquisition

The primary currents are converted by one 3phase current transformers (”Ct” block)

One measurement element (”Measurement” block) is fed by this CT.

3.1.1 Available Units and input signals

The measurement part of the relay model consists of the following elements:

• One 3 phase current transformers converting the phase currents (”Ct” block).

• One 3 phase measurement elements calculating the current RMS values (”Measurement”
block).

The following relay input signals are available:

• w_trip(1)

• w_trip(2)

Both input signals are connected to the reclosing element (”Phase recllogic” block). w_trip(1)
is controlling the phase reclosing sequence and w_trip(2) is controlling the ground reclosing
sequence.

The ”Reclosing Link” interconnection scheme available in the relay model folder, shows how
to connect to an instance of the Alstom LFAA relay model (”R2” in the scheme) the protective
relay (”R1” in the scheme) which sends the trip command. Please configure the names of the
protective relay trip signals accordingly with the names of the available relay output signals.

3.1.2 Functionality

The input currents are sampled at 20 samples/cycle. The values are then integrated over a cycle,
and the RMS value is provided to the reclosing element.

3.1.3 Data input

The CT secondary rated current (1 or 5 A) value must be set in the measurement element
(”Nominal current” parameter).

Alstom LFAA Version: 001 4


3 Supported features

3.2 Main Relay protective elements

The reclosing element and the overcurrent element are working together to simulate the Al-
stom LFAA reclosing functionalities.

3.2.1 Available Units

• One 3phase reclosing element (”Phase recllogic” block).


• One overcurrent element (”0 current detector” block).

3.2.2 Functionality

Overcurrent element The overcurrent element acts as zero current detector.

Reclosing elements The reclosing element is driven by the relay input signals (”w_trip(1)”
and ”w_trip(2)”). The Alstom LFAA relay model reclosing feature is operating only when such
signals are carrying the trip signals generated by an external scheme (typically a protection relay
not containing the reclosing feature).

Different Open Interval times can be inserted for the first reclosing attempt and for the following.
A different Open Interval times can be defined for the first reclosing attempt after that a single
phase trip has been detected. The reclosing logic can be defined in the "Logic" tab page.

The overcurrent element (”0 current detector” block) is used to detect the open breaker condition.

3.2.3 Data input

The relationships between the relay settings and the model parameters can be found in the
following tables (the relay model parameter names are listed between brackets):

Reclosing feature :

Address Relay Setting Model block Model setting Note


Dead time high speed sin- Phase recllogic Reclosing int 1 1Ph-Grnd faults (cre-
gle phase reclosing cltime11ph)
Dead time high speed three Phase recllogic Reclosing interval 1 (crecltime1)
phase reclosing
Dead time delayed second Phase recllogic Reclosing interval 2 (crecltime2)
shot three phase reclosing
Reclaim time Phase recllogic Reset Time (cresetime)
Reclose pulse Phase recllogic Closing command duration (closing-
comtime)

Overcurrent :

No user input is required.

Alstom LFAA Version: 001 5


3 Supported features

3.3 Output logic

The output logic is the interface between the relay and the power system. A set of relay output
signals is available and can be used by the user to implement any control logic using external
control schemes.

3.3.1 Available Units and Signals

The trip logic is implemented by the ”Output Logic” block, the reclosing logic by the ”Closing logic”
block.

The following relay output signals are available:

• yout (”Phase recllogic” close command)


• yout1 (”Phase recllogic” trip command)

3.3.2 Functionality

The ”Output Logic” block operates the power breaker when a trip condition has been detected by
the recloser element (”Phase recllogic” block).

The ”Closing logic” block closes the power breaker when the recloser element triggers a reclosing
attempt (”Phase recllogic” block).

3.3.3 Data input

Please disable the ”Output Logic” block to disable the relay model ability to open the power
breaker.

Please disable the ”Cosing Logic” block to disable the relay model ability to close the power
breaker.

Alstom LFAA Version: 001 6


4 Main relay scheme

4 Main relay scheme

Figure 4.1: Alstom LFAA relay connection scheme

Alstom LFAA Version: 001 7


4 Main relay scheme

Figure 4.2: Alstom LFAA ”Reclosing link” interconnection scheme

Alstom LFAA Version: 001 8


5 Features not supported

5 Features not supported

The following features are not supported:

• Block autoreclose input.


• Single phase trip and reclosing.
• Conversion of any single or two-phase tripping into a three-phase tripping.

Alstom LFAA Version: 001 9


6 References

6 References
[1] ALSTOM T&D Protection & Control Ltd, St Leonards works, Stafford ST17 4LX England.
Types LFAA 101, 102 Auto-Reclose Relay R-4076H, 1999.

Alstom LFAA Version: 001 10


7 Change Log

7 Change Log

Version Date Comments


001 June 29, 2012 Initial version 13.2

Alstom LFAA Version: 001 11