Model S3: Stainless Steel Pressure Gauges - Dry or Liquid Filled
Model S3: Stainless Steel Pressure Gauges - Dry or Liquid Filled
Model S3: Stainless Steel Pressure Gauges - Dry or Liquid Filled
Designed for heavy duty service in process and industrial applications such as
chemical, petrochemical, power, food processing
SPECIFICATIONS:
DIMENSIONS:
DRAWINGS FOR LOWER BACK MOUNT BASED ON 4" AND 6"
DIAL A B C D E F G J K L M P R S
2-1/2" 2.66" 3.19" 2.95" 0.43" 0.14" 0.69" 1.46" 2.48" 1.12" 0.55"
(67,6mm) (81mm) (75mm) (11mm) (3,6mm) (17,5mm) (37mm) (63mm) (28,5mm) (14mm)
4" 4.01" 2.48" 5.12" 4.65" 1.00" 0.91" 1.24" 0.22" 2.22" 1.55" 2.70" 3.84" 1.95." 0.77"
(101,7mm) (63mm) (130mm) (118mm) (25,5mm) (23mm) (31,5mm) (5,5mm) (56,5mm) (39,3mm) (68,5mm) (97.5mm) (49,5mm) (19.5mm)
6" 5.91" 3.35" 7.09" 6.61" 1.00" 0.91" 1.24" 0.22" 2.22" 1.55" 2.70" 5.59" 2.15" 0.87"
(150,2mm) (85mm) (180mm) (168mm) (25,5mm) (23mm) (31,5mm) (5,5mm) (56,5mm) (39,3mm) (68,5mm) (142mm) (54,5mm) (22mm)
Page 1
BourBrick Manufacturing Company
197 Waterside Street, Leicester, England, United Kingdom.
Phone: +44 116 765 8894 • E-mail: [email protected] • Web: www.bourbrick.uk
PART NUMBER:
DIAL MODEL TUBE & CASE CONN. CONN. CONN. RANGE & OPTIONS
CODE SOCKET SIZE LOCATION TYPE SCALE
2 = 2-1/2" S3 S = SS-316 S = SS-316 4 = 1/4" L = Lower 1 = NPT See Range E = Back Flange
M = Monel C = Center Back 2 = BSP Table F = Front Flange
(Up to range G = Glycerine Fill
of 10,000 psi) R = Restrictor
S = Silicone Fill
O = Oxygen Cleaning
4 = 4" S3 S = SS-316 S = SS-316 2 = 1/2" L = Lower 1 = NPT See Range D = Drag Pointer
M = Monel 4 = 1/4" B = Lower Back 2 = BSP Table E = Back Flange
F = Front Flange
G = Glycerine Fill
R = Restrictor
S = Silicone Fill
V = U-Clamp
O = Oxygen Cleaning
6 = 6" S3 S = SS-316 S = SS-316 2 = 1/2" L = Lower 1 = NPT See Range E = Back Flange
M = Monel B = Lower Back 2 = BSP Table F = Front Flange*
G = Glycerine Fill
S = Silicone Fill
R = Restrictor
O = Oxygen Cleaning
Example:
Select: 4-S3-SS4L1-F10G
STANDARD RANGES:
Vacuum / Pressure Pressure High Pressure
CODE = RANGE INTERVALS DIVISIONS CODE = RANGE INTERVALS DIVISIONS CODE = RANGE INTERVALS DIVISIONS
(psi) (Hg) (psi) (Hg) (psi) (psi) (psi) (psi) (psi) (psi) (psi)
V1A = 30" Hg 5" .2" D15 = 0-15 3 .1 M10 = 0-1000 100 10
V2B = 30-0-15 5" 5 .5" .2 D30 = 0-30 5 .2 M15 = 0-1500 300 10
V3C = 30-0-30 5" 5 1" .5 D60 = 0-60 10 .5 M20 = 0-2000 200 20
V4D = 30-0-60 10" 10 1" 1 F10 = 0-100 10 1 M30 = 0-3000 500 20
V5E = 30-0-100 30" 10 5" 2 F16 = 0-160 20 2 M40 = 0-4000 500 50
V6F = 30-0-160 30" 20 5" 2 F20 = 0-200 20 2 M50 = 0-5000 500 50
V7G = 30-0-200 30" 20 5" 2 F30 = 0-300 50 2 K10 = 0-10,000 1000 100
F40 = 0-400 50 5 K15 = 0-15,000 3000 100
F60 = 0-600 100 5
F80 = 0-800 100 10
NOTE: INTERVALS AND DIVISION BASED ON 4" DIAL SIZE. CONTACT FACTORY TO REQUEST INFORMATION ON OTHER DIAL SIZES.
NOTE: ABOVE 15,000 PSI AVAILABLE ONLY WITH 1/2" BSP STRAIGHT CONNECTION (G1/2).
NOTE: OTHER RANGES AND SCALES AVAILABLE. CONSULT FACTORY.
Page 2