Model "F" Non-Ported Seating Nipple: Flow Control Systems Technical Unit

This document provides information on Baker Oil Tools' Model "F" Non-Ported Seating Nipple. It can be used to locate, seal, and retain downhole flow control accessories. The nipple contains a top no-go shoulder and locking groove to enable selective and top no-go landing of accessories. It is available in different materials and sizes to match various downhole accessory products and tubing strings. Dimensional data and specifications are provided for proper application.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
502 views3 pages

Model "F" Non-Ported Seating Nipple: Flow Control Systems Technical Unit

This document provides information on Baker Oil Tools' Model "F" Non-Ported Seating Nipple. It can be used to locate, seal, and retain downhole flow control accessories. The nipple contains a top no-go shoulder and locking groove to enable selective and top no-go landing of accessories. It is available in different materials and sizes to match various downhole accessory products and tubing strings. Dimensional data and specifications are provided for proper application.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Unit No.

8001
Baker Oil Tools Index: 480.10
Replaces 3414
FLOW CONTROL SYSTEMS Date: October 1, 1999
TECHNICAL UNIT Page:1 of 3

Model “F” Non-Ported Seating Nipple


Product Family Nos. H80150, H80151 and H80152

Description
Product Family Nos.
H80150 - Model “F” Non-Ported Seating Nipple,
Alloy Steel
H80151 - Model “F” Non-Ported Seating Nipple,
Stainless Steel
H80152 - Model “F” Non-Ported Seating Nipple,
9Cr-1Mo
The Baker Model “F” Non-Ported Seating Nip-
ple is a downhole tubing nipple used to locate,
seal, and retain Baker Flow Control accessories
which utilize selective and/or top no-go locking de-
vices. These accessories, which are run and re-
trieved on wireline, will enable virtually any
downhole flow control operation to be performed.
The Model “F” contains a top no-go shoulder
and a locking groove. The shoulder and groove are
used for top no-go landing; groove only is used in
selective locating and landing.
Any number of “F” nipples can be used in one
tubing string where selective Model “S” Locks are
used with the downhole accessory product.

Features / Benefits
• Material Selection - Alloy steel, stainless steel
and 9Cr-1Mo are heat-treated to NACE
specifications. (Hardness is 20-22 Rc.)
• Versatility - Functions in top no-go or selective
systems.
• Seal Bore - Contoured and polished to pass
chevron packing without damage.
• Integral locking groove.
• OD same as Coupling OD with properties
corresponding to N-80 or better.
• Nipples ordered with Turned-down ODs
correspond to turned-down N-80 couplings in
diameter and properties.
• Service Chevron Packing is standard on all Drawing No. 295-398
accessories.

This document contains Confidential Information of Baker Hughes Incorporated (Baker) and is furnished to the customer for information purposes only. It is
requested that this document not be reproduced in any way whatsoever, in part or in whole, or distributed outside the customer organization without first obtaining
the express written authorization of Baker. This document is the property of Baker and returnable on request of Baker.  October, 1999, Baker Hughes
Unit No. 8001 10-1-99 Model “F” Non-Ported Seating Nipple
Index: 480.10 Page 2 of 3

Accessory Products
WARNING
Use of Baker equipment contrary to Refer to units filed under Indexes 480.30,
manufacturer’s specification may result in 480.60, and 480.70 for complete information on
property damage, serious injury or fatality. Baker Flow Control accessories (chokes, blanking
plugs, check valves, safety valves, etc.) which may
be located in the seal bore of the Model “F” Non-
Ported Seating Nipple.
Availability Chart
Nipple BFC Downhole Accessories Nipple BFC Downhole Accessories
Size Selective Top No-Go Size Selective Top No-Go
1.18 ∆ ∆ 2.81 ∆ ∆
1.25 ∆ ∆ 2.87 ∆
1.43 ∆ ∆ 3.12 ∆
1.50 ∆ ∆ 3.31 ∆
1.56 ∆ ∆ 3.68 ∆ ∆
1.62 ∆ 3.75 ∆ ∆
1.78 ∆ ∆ 3.81 ∆ ∆
1.81 ∆ ∆ 4.00 ∆
1.87 ∆ ∆ 4.12 ∆
2.06• ∆ 4.31 ∆
2.18 ∆ ∆ 4.56 ∆
2.25 ∆ ∆ 4.75 ∆
2.31 ∆ ∆ 5.25 ∆
2.56 ∆ ∆ 5.50 ∆
2.75 ∆ ∆ 5.95 ∆
∗Refer to Seal Bore Selector Chart, Unit No. 8003, Index 480.00, for complete tubing details.
•Limited flow control accessories for size 2.06.

Dimensional Data, Sizes 1.18 - 2.06


Refer to Drawing Nos. 295-398 For Sizes 1.18 - 3.81 (Except 2.06, 3.12 and 3.31)
and 230-835 For Sizes 2.06, 3.12, 3.31 & 4.00 - 5.95.
Size
Dim
1.18 1.25 1.43 1.50 1.56 1.62 1.78 1.81 1.87 2.06
Seal
1.187 1.250 1.437 1.500 1.562 1.625 1.781 1.812 1.875 2.062
Bore
A 1.305 1.565 1.705 1.950 2.190
B 1.62 1.87 2.00 2.31 2.53
C 4.67 4.78 5.27 5.32 5.22 5.26 6.17 6.16 6.21 7.00
D 5.84 5.89 6.42 6.41 6.38 6.37 7.36 7.32 7.31 8.10
E♦ 10.25 - 11.00 11.00 -15.00 12.00 - 17.00 15.00 - 17.00

Size
Dim
2.18 2.25 2.31 2.56 2.75 2.81 2.87 3.12 3.31 3.68
Seal
2.188 2.250 2.312 2.562 2.750 2.812 2.875 3.125 3.313 3.688
Bore
A 2.235 2.380 2.749 2.925 2.925 2.970 3.250 3.411 3.886
B 2.86 2.81 3.21 3.37 3.38 3.59 3.81 4.37
C 8.37 6.48 6.52 12.03 6.96 7.06 3.69 3.32 7.08
D 9.37 7.64 7.63 13.03 8.17 8.22 8.06 11.64 11.27 8.32
16.00 -
E♦ 13.00 - 18.00 21.00 - 23.00 13.00 - 18.00 17.00 - 19.00 18.00 - 20.00 16.12 - 18.62
18.00

Size
Dim
3.75 3.81 4.00 4.12 4.31 4.56 4.75 5.25 5.50 5.95
Seal
3.750 3.812 4.000 4.125 4.313 4.562 4.750 5.250 5.500 5.953
Bore
A 3.886 4.125 4.312 4.437 4.718 4.875 5.375 5.625 6.125
B 4.37 4.56 4.75 4.87 5.12 5.43 6.00 6.00 6.68
C 7.32 7.30 3.72 3.68 3.49 4.18 4.19 3.18 3.55 4.70
D 8.50 8.43 13.44 13.47 12.91 13.75 13.27 13.26 13.63 14.73
E♦ 16.12 - 18.62 22.50 - 25.00 23.00 - 27.00 22.25 - 25.25 23.00 - 25.25 22.00 - 27.25 23.87 - 26.50 24.50 - 26.75
♦Length of nipple is as shown, varying with tubing size, thread and bore size relationships.
Model “F” Non-Ported Seating Nipple Unit No. 8001 10-1-99
Index: 480.10 Page 3 of 3

Dimensional Data Drawing No. 295-398 - Sizes 1.18 - 3.81 (Except 2.06, 3.12 and 3.31)

Dimensional Data Drawing No. 230-835 - Sizes 2.06, 3.12, 3.31 and 4.00 - 5.95
NOTE: These nipple sizes will receive only collet type locks.

You might also like