4 EUTECTRODE#US En#99006#1,0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

SDS: 4 EUTECTRODE

February 1, 2014

SAFETY DATA SHEET


MAY BE USED TO COMPLY WITH OSHA'S HAZARD COMMUNICATION STANDARD, 29 CFR 1910.1200 AND SUPERFUND
AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 PUBLIC LAW 99-499.
STANDARD SHOULD BE CONSULTED FOR SPECIFIC REQUIREMENTS.

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

NAME OF PRODUCT: EUTECTRODE 4


SYNONYMS: Eutectic 4
PRODUCT CODES: 4-32-5K, 4-40-5K

MANUFACTURER/ EUTECTIC CORPORATION


SUPPLIER: N94 W14355 GARWIN MACE DRIVE
MENOMONEE FALLS, WI 53051 USA

TELEPHONE NUMBER (262) 532-4677


FAX NUMBER: (262) 255-5542
EUTECTIC WEBSITE: www.eutectic.com

PRODUCT CLASSIFICATION: Covered Electrode for Shielded Metal Arc Welding (SMAW)

SECTION 2: HAZARDS IDENTIFICATION

EMERGENCY OVERVIEW: Welding electrodes are not normally considered hazardous as shipped or when handled. Gloves
should be worn when handling to prevent cuts. Avoid inhalation of dust from these products. Skin contact may cause possible
allergic reactions. Persons with a pacemaker should not go near welding or cutting operations until they have consulted their doctor
and obtained information from the manufacturer of the pacemaker device. When this product is used in a welding process the most
important hazards are: heat, radiation, electric shock, and welding fumes.

ROUTES OF ENTRY:
Primary route of entry is the respiratory system. Other possible routes are eyes and/or skin contact.

POTENTIAL HEALTH EFFECTS:


EYES: RADIATION: Arc rays from welding can injure eyes. HEAT and MOLTEN METAL can
severely damage eyes.
SKIN: HEAT: Spatter and molten metal can cause burn injuries
ELECTRICITY: Electric shock can kill!
RADIATION from the arc: Skin cancer has been reported.
INGESTION: Not an expected route of entry, but if ingested product could cause serious injury.
INHALATION: FUMES: Overexposure to welding fumes may result in symptoms like metal fume fever,
dizziness, nausea, dryness of the nose, throat or eyes.

ACUTE HEALTH HAZARDS: See Section 11


CHRONIC HEALTH HAZARDS: See Section 11
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Nothing found.

WARNING: This product contains or produces a chemical known to the State of California to cause birth defects (or other
reproductive harm) and cancer. (California Health & Safety Code 25249.5 et seq.)

WARNING: avoid breathing welding fumes and gases; they may dangerous to your health. Always use adequate ventilation and
use appropriate personal protection equipment.

Page 1 of 11
SDS: 4 EUTECTRODE
February 1, 2014

CARCINOGENICITY:
CHROMIUM - Chromium VI is listed as being carcinogenic to humans on IARC and NTP lists, and is listed by NIOSH as being
a potential occupational carcinogen (with no further categorization).
NICKEL - is listed as being carcinogenic to humans on IARC and NTP lists, and is listed by NIOSH as being a potential
occupational carcinogen (with no further categorization).
MANGANESE is listed by ACGIH as Group A4: Not classifiable as a human carcinogen.
TITANIUM DIOXIDE is listed as being unclassifiable as to Carcinogenicity in humans by IARC and is listed by NIOSH as being
a potential occupational carcinogen (with no further categorization).
SILICON DIOXIDE - is listed as being carcinogenic to humans on IARC and NTP lists, and is listed by NIOSH as being a
potential occupational carcinogen (with no further categorization).
WELDING FUMES (not otherwise specified) are considered to be carcinogenic defined with no further categorization by NIOSH
and IARC.

Package Labeling:

Although this product does not require a hazard warning label in all countries, we recommend that the safety advice should be
observed:
Pictograms: GHS07- GHS08

Contains Nickel
R-Phrases:
Limited evidence of carcinogenic effect
May cause sensitization by skin contact
Toxic: danger of serious damage to health by prolonged exposure through inhalation
Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment
Brazing/welding fumes and vapors may cause metal fume fever (headache, dizziness, dryness, cough, nausea, and fever) and these
symptoms may appear 4-12 hours after exposure
May cause irritation by prolonged inhalation of brazing/welding fumes.

GHS:
Hazard categories:
Respiratory/skin sensitization: Skin Sens: 1
Carcinogenicity: Carc. 2
Specific target organ toxicity – repeated exposure: STOT RE 1
May cause an allergic skin reaction.
Suspected of causing cancer.
Causes damage to organs through prolonged or repeated exposure.

Hazard Statements:
H317 May cause an allergic skin reaction
H351 Suspected of causing cancer
H372 Causes damage to organs through prolonged or repeated exposure

Precautionary Statements:
P285 In case of inadequate ventilation wear respiratory protection
P314 Get medical advice if you do not feel well
P280 Wear protective gloves/protective clothing/eye protection/face protection
P202 Do not handle until all safety precautions have been read and understood
P260 Do not breathe dust/fume/gas/mist/vapors/spray
P501 Dispose of contents/container to waste treatment facility in accordance with local and national regulations

Page 2 of 11
SDS: 4 EUTECTRODE
February 1, 2014

SECTION 2 NOTES: Before using this product, contact your doctor to determine if exposure to product or use of this product will
aggravate your medical conditions.

ADDITIONAL LABELING INFORMATION


As an article the product does not need to be labeled in accordance with EC-directives or respective national laws.
Metals in massive form, alloys, mixtures containing polymers and mixtures containing elastomers do not require a label
according to this Annex (Annex I GHS), if they do not present a hazard to human health by inhalation, ingestion or
contact with skin or to the aquatic environment in the form in which they are placed on the market, although classified as
hazardous in accordance with the criteria of this Annex.

Instead, the supplier shall provide the information to downstream users or distributors by means of the SDS.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS

IMPORTANT: This section covers the materials from which these products are manufactured. The fumes and gases produced
during normal use of these products are covered in Section 8. The chemicals or compounds subject to reporting under Title III, in
Section 313, of the Superfund Amendments and Reauthorization Act (SARA) are marked by the symbol #.

CAS Exposure Limit (mg/m3)


INGREDIENTS NUMBER OSHA PEL ACGIH-TLV Percent Ingredients (by weight)
Iron 7439-89-6 10 (as Fe) 5 (as Fe) 30 – 60
Chromium # 7440-47-3 1 0.5 5 – 10
Manganese # 7439-96-5 5 (ceiling) 0.1 5 – 10
Titanium Dioxide 13463-67-7 15 10 5 – 10
Nickel # 7440-02-0 1 0.2 1–5
Calcium Fluoride 7789-75-5 2.5 (as F) 2.5 (as F) 1–5
Cellulose 9004-34-6 5 10 1–5
Feldspar 68476-25-5 10 2 1–5
Magnetite 1309-38-2 15 5 1–5
Potassium Titanate 12030-97-6 Not listed Not listed 1–5
Molybdenum 7439-98-7 5 5 1–5
Potassium Silicate 1312-76-1 Not listed Not listed 1–5
Silicon Dioxide 14808-60-7 ** 0.05 0.1 – 1
** 10 mg/m³ / (% SiO2 + 2)

CAS / EINECS NUMBER / HAZARD CLASSIFICATION FOR ABOVE INGREDIENTS IF PRESENT


Hazard Classification per
INGREDIENTS CAS NUMBER EINECS Number
ECD 675/548/ECC
Aluminum # 7429-90-5 231-072-3 No (flux coating component)
Barium Carbonate # 513-77-9 208-167-3 Xn; R22
Boron 7440-42-8 231-151-2 No
Calcium Carbonate 1317-65-3 215-279-6 No
Calcium Fluoride 7789-75-5 232-188-7 No
Carbon 7440-44-0 231-153-3 No
Cellulose 9004-34-6 232-674-9 No
Chromium # 7440-47-3 231-157-5 No
Cobalt Aluminate Blue Spinel # 1345-16-0 310-193-6 No
Columbium (Niobium) 7440-03-1 231-113-5 No
Copper # 7440-50-8 231-159-6 No
Feldspar 68476-25-5 270-666-7 No

Page 3 of 11
SDS: 4 EUTECTRODE
February 1, 2014

Graphite 7782-42-5 231-955-3 No


Iron 7439-89-6 231-096-4 No
Iron Oxide 1309-38-2 215-169-8 No
Lamp Black (Carbon Black) 1333-86-4 215-609-9 No
Lithium Aluminum Silicate (Al #) 12068-40-5 235-098-6 No
Magnesium Fluoride 7783-40-6 231-995-1 No
Magnetite 1309-38-2 215-277-5 No
Manganese # 7439-96-5 231-105-1 No
Molybdenum 7439-98-7 231-107-2 No
Nickel # 7440-02-0 231-111-4 Carc. Cat. 3; R40 - T; R48/23 - R43
Potassium Hydroxide 1310-58-3 215-181-3 No
Potassium Oxalate 6487-48-5 209-506-8 No
Potassium Silicate 1312-76-1 215-199-1 No
Potassium Titanate 12030-97-6 234-748-6 No
Silicon Dioxide 14808-60-7 238-878-4 No
Sodium Silicate 1344-09-8 215-687-4 No
Titanium 7440-32-6 231-142-3 No
Titanium Dioxide 13463-67-7 236-675-5 No
Tungsten 7440-33-7 231-143-9 No
Tungsten Carbide 12070-12-1 235-123-0 No
Vanadium # 7440-62-2 231-171-1 No
Zirconium silicate (zircon) 14940-68-2 239-019-6 No

SECTION 3 NOTES: Exposure limits are subject to change. Contact ACGIH and OSHA for current values. See Section 16 for
European Council Directive 67/548/EEC R-phrases and S-phrases if applicable.

SECTION 4: FIRST AID MEASURES

EMERGENCY & FIRST AID PROCEDURES: Call for medical aid. Employ first aid techniques recommended by The
American Red Cross.

EYES: Flush with a large amount of fresh water for at least 15 minutes to remove dusts or fumes. Get medical attention. For
radiation burns due to arc flash, see physician.
SKIN: Wash affected area with soap and water to remove dust or particles. If rash develops, see a physician. For skin burns from
arc radiation, promptly flush with cold water. Get medical attention for burns or for irritations that persist.
INGESTION: Seek medical attention.
INHALATION: Remove to fresh air. If breathing is difficult administer oxygen. If breathing has stopped, begin artificial
respiration and obtain medical assistance immediately.
ELECTRIC SHOCK: Disconnect and turn off the power. Use a nonconductive material to pull victim away from contact with
live wire parts or wires. If breathing has stopped, begin artificial respiration and obtain medical assistance immediately. If no
detectable pulse, begin Cardiopulmonary Resuscitation. (CPR) and immediately call for medical aid.

GENERAL: Move to fresh air and call for medical aid.

NOTES TO PHYSICIANS OR FIRST AID PROVIDERS:


When the electrode is consumed, fume and gas decomposition products generated are different in percent and form from the
ingredients listed in Section 3. Fume and decomposition products, not the ingredients in the electrode, are important.
Decomposition products include those originating from the volatilization, reaction, or oxidation of materials in Section 3, plus those
from the base metal, etc.,as noted above. These components are virtually always present as complex oxides and not as metals
(Characterization of Arc Welding Fume: American Welding Society). See Section 11.

SECTION 4 NOTES: None.

Page 4 of 11
SDS: 4 EUTECTRODE
February 1, 2014

SECTION 5: FIRE FIGHTING MEASURES

Non-Flammable: Welding arc and sparks can ignite combustibles. Refer to American National Standard Z49.1 for fire prevention
during welding. These products as shipped are non-hazardous, nonflammable, non-explosive, and non-reactive.

FLAMMABLE LIMITS IN AIR (% by volume): UPPER: N/A LOWER:N/A

FLASH POINT: N/A

AUTOIGNITION TEMPERATURE: N/A

NFPA HAZARD CLASSIFICATION:


Health: 2 Flammability: 0 Reactivity: 0 Other:

RATING UNDER NATIONAL FIRE PROTECTION 704:


Health: 2 Flammability: 0 Reactivity: 0 Protection:

EXTINGUISHING MEDIA: Use the extinguishing media recommended for the burning material and fire situation.

SPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained breathing apparatus as fume or vapors may be harmful.

UNUSUAL FIRE AND EXPLOSION HAZARDS: None

HAZARDOUS DECOMPOSITION PRODUCTS: Reasonably expected fume constituents of the fume could include complex oxides
of iron.

SECTION 5 NOTES: None

SECTION 6: ACCIDENTAL RELEASE MEASURES

ACCIDENTAL RELEASE MEASURES: Solid objects may be picked up and placed in a container. Wear protective clothing and
make sure that the solid objects are at room temperature before handling.

PERSONAL PRECAUTIONS: See section 8

ENVIRONMENTAL PRECAUTIONS: See section 12 and 13

SECTION 6 NOTES: None

SECTION 7: HANDLING AND STORAGE

HANDLING: Handle with care to avoid cuts and to keep the wire from piercing the skin. Wear gloves when handling welding
consumables. Avoid exposure to dust and do not ingest. Some individuals can develop and allergic reaction to certain materials. Keep all
warning labels and identification labels on the product.

STORAGE: Keep material sealed and dry before use and do not remove product identification label or warning label. After using, keep
remaining product sealed and dry and do not remove product identification label or warning label.

SECTION 7 NOTES: None

Page 5 of 11
SDS: 4 EUTECTRODE
February 1, 2014

SECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION

Read and understand the manufacturer's instructions and precautionary label on this product.
Always use adequate ventilation and wear appropriate personal protection. Do not breathe welding fumes and gases; they are
dangerous to your health.
See American National Standard Z49.1, Safety in Welding and Cutting, published by the "American Welding Society," 550 N.W.
LeJeune Road, Miami, FL 33126 and OSHA Publication 2206 (29CFR 1910), U.S. Government Printing Office, Superintendent of
Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 for more detail on the following:

ENGINEERING CONTROLS: Proper ventilation must be maintained.

ARC RAYS and SPARKS can injure eyes and burn skin. ELECTRIC SHOCK can kill! Wear correct hand, eye, head, and body
protection.

VENTILATION: Use enough ventilation, local exhaust at the arc, or both, to keep the fumes and gases below the TLV's in the
workers breathing zone and the general area. Train the welder to keep their head out of the fumes. Monitor fume levels and do not
exceed permissible exposure limits or values.
RESPIRATORY PROTECTION: Use respirable fume respirator or air supplied respirator when welding in a confined space or
where local exhaust or ventilation does not keep exposure below the TLV's.
EYE PROTECTION: Wear a helmet or face shield with a filter lens of shade 12 or darker. Provide screens and flash goggles to
shield others.
PROTECTIVE CLOTHING: Wear head, hand, and body protection which help to prevent injury from radiation, sparks, and
electrical shock. See ANSI Z49.1. At a minimum, this includes welders’ gloves and a protective face shield and may include arm
protectors, aprons, hats, shoulder protection, as well as dark substantial clothing. Train the welder not to touch live electrical parts
and to insulate themselves from work and ground, especially if clothing and gloves are wet.
WORK HYGIENIC PRACTICES: Do not eat or consume beverages in the work area.

EXPOSURE GUIDELINES: Use industrial hygiene monitoring equipment to ensure that exposure does not exceed applicable
national exposure limits. When the electrode is consumed, fume and gas decomposition products generated are different in percent
and form from the ingredients listed in Section 3. The fume and decomposition products, not the ingredients in the electrode, are
important. Decomposition products include those originating from the volatilization, reaction, or oxidation of materials in Section 3,
plus those from the base metal, etc., as noted above. These components are virtually always present as complex oxides and not as
metals (Characterization of Arc Welding Fume: American Welding Society). Reasonably expected fume constituents of the fume
could include complex oxides of iron, manganese, chromium and nickel. The following limits can be used as guidance. Refer to
Section 11 for more information about welding fumes.

CAS Exposure Limit (mg/m3)


Substance NUMBER OSHA PEL ACGIH-TLV
Iron Oxide 1309-37-1 10 (as Fe) 5 (as Fe)
Nitric Oxide 10102-43-9 30 31
Chromium (VI) not listed 0.005 0.05 (as Cr VI)
Nickel Oxide # 1313-99-1 1 (as Ni) 0.2 (as Ni)
Manganese fume # 7439-96-5 5 0.02

Page 6 of 11
SDS: 4 EUTECTRODE
February 1, 2014

Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may also be formed by
radiation from the arc. The fume limit for Cr VI (5 micrograms/m³) may be reached before the ACGIH recommended general
welding fume limit of 5 mg/m³ is reached. Monitor fume levels and Cr VI level. Train workers about the hazards of Cr (VI). Read
and comply with the OSHA permissible exposure limits for hexavalent chromium (CrVI), Fed. Reg. 71 – 10099 (specifically
29 CFR 1910.1026, 29 CFR 1915.1026, and 29 CFR 1926.1126). For CrVI, OSHA requires: “The employer shall perform initial
monitoring to determine the 8-hour TWA exposure for each employee on the basis of a sufficient

number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification,
in each work area”. Specialized equipment is required for monitoring Cr (VI) concentration in the workplace. OSHA Analytical
Method Number ID-215 for area and breathing zone sampling and OSHA Analytical Method Number W4001 for wipe samples are
listed on the OSHA website - www.osha.gov -as methods for measuring Cr(VI). This standard is complex and the employer should
contact an occupational health professional for doing the Cr(VI) monitoring and all other fume monitoring.

SECTION 8 NOTES: Exposure limits are subject to change. Contact ACGIH, OSHA, NIOSH, and IARC for current values.

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

APPEARANCE: Solid appearance, non volatile, wire with a flux coating. No odor. Not soluble in water.

MELTING POINT: > 1800 °F (> 1000 °C)

SECTION 9 NOTES: None

SECTION 10: STABILITY AND REACTIVITY

GENERAL: These items are only intended for normal welding purposes.
STABILITY: Stable under normal conditions.
HAZARDOUS POLYMERIZATION: Will not occur
REACTIVITY: Contact with chemical substances like acids or strong bases could cause generation of gas.

HAZARDOUS DECOMPOSITION OR BY-PRODUCTS:


Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may also be formed by
radiation from the arc.

Refer to applicable national exposure limits for the fume compounds. Reasonably expected fume constituents of the fume could
include complex oxides of iron, chromium, nickel and manganese. The employer should contact an occupational health
professional for doing fume monitoring to determine fumes emitted and to ensure compliance to the applicable country limits.

SECTION 10 NOTES: Manganese also has a low exposure limit listed in the USA. Other country exposure limits may be
different and the appropriate country standards should be used.

SECTION 11: TOXICOLOGICAL INFORMATION

Welding fumes cannot be classified simply. The composition and quantity of both are dependent upon the metal being welded, the
process, procedure, and the electrode used. Other conditions which also influence the composition and quantity of the fumes and
gases to which workers may be exposed include: coatings on the metal being welded (such as paint, plating, or galvanizing), the
number of welders and the volume of the work area, the quality and the amount of ventilation, position of the welder's head with
respect to the fume plume, as well as the presence of contaminants in the atmosphere (such as chlorinated hydrocarbon vapors from
cleaning and degreasing activities). The International Agency for Research on Cancer has classified welding fumes as possibly
carcinogenic to humans (group 2B).

EFFECTS OF OVEREXPOSURE - Electric arc welding may create one or more of the following health hazards:

FUMES AND GASES can be dangerous to your health.

Page 7 of 11
SDS: 4 EUTECTRODE
February 1, 2014

PRIMARY ROUTES OF ENTRY are the respiratory system. Other possible routes are eyes and/or skin contact.
PREEXISTING respiratory or allergic conditions may be aggravated in some individuals (i.e. asthma, emphysema).

SHORT TERM (ACUTE) OVEREXPOSURE to welding fumes may result in discomfort such as metal fume fever, dizziness,
nausea, or dryness or irritation of nose, throat, or eyes. PRIMARY ROUTE OF ENTRY is the respiratory system. IRON, IRON
OXIDE, MANGANESE - Remove from overexposure and apply artificial respiration if needed. CHROMIUM- Inhalation of
chromium can cause irritation of nasal membranes and skin. FLUORIDES - Fluoride compounds produced may cause eye and skin
burns, and pulmonary edema bronchitis. Exposure to extremely high levels of fluorides can cause abdominal pain, diarrhea,
muscular weakness, and convulsions. In extreme cases it can cause loss of consciousness and death. NICKEL, NICKEL
OXIDE - May cause metallic taste, nausea, tightness in chest, fever, and allergic reactions.

LONG TERM (CHRONIC) OVEREXPOSURE may lead to siderosis (iron deposits in lungs) and is believed by some
investigators to affect pulmonary functions. PRIMARY ROUTE OF ENTRY is the respiratory system. IRON, IRON
OXIDE - Long term overexposure to iron fumes can cause deposits of iron in the lungs (siderosis). Lungs will clear in time when
exposure to iron and its compounds cease. MANGANESE - Long term exposure may lead to "Manganism.” Central nervous
system is affected and symptoms include muscular weakness, impaired speech, impaired movement, and tremors. Exposed workers
should get quarterly medical examinations for manganism. Bronchitis and some lung fibrosis have been reported.
FLUORIDES - Overexposure to fluorides can cause serious bone erosion, excessive calcification of the bone and calcification of
the ribs, pelvis and spinal column. May cause skin rash. NICKEL, NICKEL OXIDE - Long term overexposure to nickel products
may cause lung fibrosis or pneumoconiosis. Long term overexposure to HEXAVALENT CHROMIUM (CrVI) is reported to
cause lung cancer in humans.

SECTION 11 NOTES: Monitor fume levels and do not exceed permissible limits.

SECTION 12: ECOLOGICAL INFORMATION

MATERIAL: Welding consumables and materials can degrade into the components used to manufacture the product. Avoid exposure to
conditions that could lead to accumulation in soils and groundwater.

CONTAMINATED PACKAGING: Empty containers should be taken for local recycling, recovery, or waste disposal. Metals may be
recycled.

SECTION 12 NOTES: None.

SECTION 13: DISPOSAL CONSIDERATION

WASTE DISPOSAL METHOD: Dispose of any grinding dust and waste residues in accordance with EPA or local regulations.
Plastic materials, cardboard, and wire can be re-cycled.

U.S.A. RCRA: Some unused product may contain chromium which is considered hazardous waste if discarded, RCRA ID
characteristic Toxic Hazardous Waste D007. Other ingredients in this product may be considered “hazardous material” in other
countries and they may require special disposal methods. Contact your local municipality for the proper disposal method.
Residues from welding consumables and processes could degrade and accumulate in groundwater. Welding slag from these
products could typically contain the following components from the coating of the electrode: Ni, Fe, Sr, Mn, F, Na, Si, Ca, and C.

SECTION 13 NOTES: None

Page 8 of 11
SDS: 4 EUTECTRODE
February 1, 2014

SECTION 14: TRANSPORTATION INFORMATION

DOMESTIC TRANSPORT REGULATIONS (USA): DOT - not regulated.

DOMESTIC TRANSPORT REGULATIONS (CANADA): TDG - not regulated.

DOMESTIC TRANSPORT REGULATIONS (MEXICO): MEX - not regulated.

INTERNATIONAL TRANSPORT REGULATIONS:


ICAO – not regulated
IATA – not regulated
IMDG / IMO – not regulated

OTHER AGENCIES: No international regulations or restrictions are applicable.

SECTION 14 NOTES: Handle with care to avoid damaging the product and keep product dry. Do not remove product identification label
or warning label.

SECTION 15: REGULATORY INFORMATION

Read and understand the manufacturer's instructions and precautionary label on this product.
See American National Standard Z49.1, Safety in Welding and Cutting, published by the "American Welding Society," 550 N.W.
LeJeune Road, Miami, FL 33126 and OSHA Publication 2206 (29CFR 1910), U.S. Government Printing Office, Superintendent of
Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 for more information. Before using this product, understand and your
employer’s safety practices.

ARC RAYS and SPARKS can injure eyes and burn skin. ELECTRIC SHOCK can kill! Wear correct hand, eye, head, and
body protection.

U.S. FEDERAL REGULATIONS: Under the OSHA Hazard Communication Standard these products are considered as hazardous.

WARNING: This product contains or produces a chemical known to the State of California to cause cancer and birth defects (or
other reproductive harm). (California Health & Safety Code 25249.5 et seq.)

U.S. EPA TSCA (TOXIC SUBSTANCE CONTROL ACT): All constituents of these products are on the TSCA inventory list or
are excluded from listing.

CERCLA (COMPREHENSIVE RESPONSE COMPENSATION, AND LIABILITY ACT)/SARA TITLE III (SUPERFUND
AMENDMENTS AND REAUTHORIZATON ACT):

Reportable Quantities (RQ’s) and/or Threshold Planning Quantities (TPQ’s):


Ingredient name: RQ (lb) TPQ(lb)
Product is a solid solution in the form of a solid article - -

Spills or releases resulting in the loss of any ingredient at or above its RQ require immediate notification to the National Response
Center and to our Local Emergency Planning Committee.

Page 9 of 11
SDS: 4 EUTECTRODE
February 1, 2014

EPCRA/SARA TITLE III 313 TOXIC CHEMICALS:


The following metallic components are listed as SARA 313 “TOXIC CHEMICALS” and are potentially subject to annual SARA
313 reporting. See Section 3 for percent and if the ingredient is present.

INGREDIENT NAME CAS DISCLOSURE THRESHOLD


Chromium & chromium compounds 7440-47-3 1.0 % de minimis concentration
Chromium VI Not listed 0.1 % de minimis concentration
Barium compounds Not listed 1.0 % de minimis concentration
Cobalt 7440-48-4 0.1 % de minimis concentration
Copper 7440-50-8 1.0 % de minimis concentration
Manganese 7439-96-5 1.0 % de minimis concentration
Nickel 7440-02-0 0.1 % de minimis concentration
Aluminum (fume or dust) 7429-90-5 1.0 % de minimis concentration
Silver 7440-22-4 1.0 % de minimis concentration

Package Labeling:
Additional advice on labeling
As a finished article the product does not need to be labeled in accordance with EC-directives or respective national laws.

SECTION 15 NOTES: International rules may vary and the appropriate regulations should be followed as defined by the country
where the products are used.

SECTION 16: OTHER INFORMATION


DATE: February 1, 2014
This Safety Data Sheet has been revised due to modifications to several paragraphs and/or new format.
Prepared by: Eutectic Corporation, USA

R-phrases
Nickel
R40 : Limited evidence of a carcinogenic effect.
R43 : May cause sensitization by skin contact.
R48/23 : Toxic: danger of serious damage to health by prolonged exposure through inhalation.

S-phrases
Nickel
S2: Keep out of the reach of children
S36/37/39 : Wear suitable protective clothing, gloves and eye/face protection
S45 : In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)
S61: Avoid release to the environment. Refer to special instructions/Safety data sheet.

Page 10 of 11
SDS: 4 EUTECTRODE
February 1, 2014

SUPPLEMENTAL INFORMATION – DEFINITIONS:

IARC: International Agency for the Research on Cancer PEL: Permissible Exposure Limit
NIOSH: National Institute for Occupational Safety and Health NTP: National Toxicology Program
OSHA: U.S. Occupational Safety and Health Administration TLV: Threshold Limit Value
ACGIH: American Conference of Governmental Industrial Hygienists ECD: European Council Directive
CAS: Chemical Abstracts Service Registry Number GHS: Globally Harmonized System
EINECS: European Inventory of Existing Chemical Substances

The information in this SDS was obtained from sources we believe are reliable. However, this information is provided without any
representation or warranty, expressed or implied, regarding accuracy or correctness. The conditions or methods of handling, storage,
use, and disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons we do not
assume responsibility and expressly disclaim liability of loss, damage, or expense arising from it or any way connected with the
handling, storage, use, or disposal of the product.

Page 11 of 11

You might also like