Hitachi VRF FSNP FSNS Series - Reduced
Hitachi VRF FSNP FSNS Series - Reduced
Hitachi VRF FSNP FSNS Series - Reduced
SET FREE Σ
03 Welcome
23 Outdoor units
87 Controllers
01 02
Air. It’s a
wonderful thing.
Living Harmony
WELCOME
uncompromising approach to innovation
and quality, we can continue to create the
technologies for a more comfortable and
balanced world.
03 04
–
Learn more about Outdoor Unit
on page 23
Redefining comfort.
WELCOME
superior energy saving.
–
Learn more about Indoor Unit
on page 59
–
Learn more about Controller
on page 87
05 06
WELCOME
The philosophy of Living Harmony shapes Our systems are designed to ensure
everything we do, but it’s really not about us. superior comfort levels by maintaining a
The design of our Variable Refrigerant Flow constant and balanced room temperature.
(VRF) systems starts with truly understanding
the needs of our customers; the people
who use, specify and install our products.
09 10
11 12
WELCOME
13 14
MAIN PRODUCTS
Air Compressor, Roller, Large Split, Refrigerators, Compressor
Casting Casting for refrigeration, Casting
Outdoor unit:
Indoor unit: Large Split controlled
Refrigerator Floor Exposed by built-in
Compressor type (RPF) micro-computer
1951
1952
1956
1958
1961
1963
1965
1970
1971
1972
1973
1976
1978
1979
WELCOME
1981
1982
1983
1984
1986
1988
1990
1991
1996
1999
2003
2005
2011
2012
2016
15 16
Features, advantages
and benefits at a glance
This table sets out the features and
benefits of the SET FREE Σ range with
your needs in mind.
WELCOME
✓✓ Easily updated in case of reconfiguration
17 18
System
WELCOME
✓✓ Extends service life
✓✓ Increases reliability Back-up Operation function
• Allows one outdoor unit module to be taken
Three step Night-quiet mode off-line for maintenance while remaining units
• Available function to limit the noise of outdoor keep operating
units (three step) ✓✓ No disruption during maintenance
✓✓ Ideal for locations with restrictions on
noise pollution
19 20
World leading Scroll Compressor technology New patented Σ shaped heat exchanger
• Japanese precision engineering • Improved heat exchange rate
✓✓ Superior reliability and quality ✓✓ Contributes to superior efficiency
Load shedding
• Turns units on/off and cycles between units at
10–20 minute intervals
✓✓ Enhanced energy savings
✓✓ Limits electric load demand
WELCOME
✓✓ Improves system management
Variety of controllers
• Large range of individual and central
controllers, from simple to advanced functions
• Intuitive and user friendly
✓✓ Meets varied user requirements
21 22
26 High efficiency
27 Better Perfomance
29 Design flexibility
33 Ease of maintenance
34 Reliability
39 Specifications
57 Optional parts
23 24
SUMMARY TABLE
Maximum equivalent piping length between ODU and IDU m 190 190
Cooling operation range with low ambient setting *** °C DB -10.0 to 52.0 **** -10.0 to 48.0 ****
EFFICIENCY RATIO
High Efficiency - FSNP Series
3.00
2.00
5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class
14.0 16.0 22.4 28.0 33.5 40.0 45.0 50.0 kW
OUTDOOR UNITS
5.08
5.00
4.54
4.21 4.06
4.00
3.00
2.00
5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class
16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.0 kW
5.00
4.54
4.22 4.13
4.00 3.68
3.43 3.47
3.24 3.16 3.11
3.00
2.00
8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class
22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 kW
2.00
8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class
25.0 31.5 37.5 45.0 50.0 56.0 63.0 69.0 77.5 kW
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
25 26
3 POINTS IMPROVEMENT
1) COMPRESSOR
Greater capacity control
100%
100% 15Hz~100Hz 100%
100% 11Hz~110Hz
The highly improved performance
as well as greater energy saving is
85 Steps 990 Steps
(by 1Hz) (by 0.1Hz)
Inverter Compressor
Inverter Compressor
Inverter Compressor
Inverter Compressor
achieved by adopting newly developed
Control Capacity
Control Capacity
Control Capacity
Control Capacity
high efficiency DC inverter compressor,
with outstandingly precise control
technology of 0.1Hz increments DCDC DCDC
inverter frequency. Another feature Inverter
Inverter
Compressor
Compressor
Inverter
Inverter
Compressor
Compressor
is the dramatically extended working 20%
20% 10%
10%
range, enabled by expanding the Max.
Max. Min.
Min.
Max.
Max. Cooling
Cooling Load
Load Min.
Min.
Cooling
Cooling Load
Load
compressor’s operating frequency
band, both upwards and downwards. Current model* New model*
*Example at 12HP class(33.5kW)
2) HEAT EXCHANGER
• The heat exchange area has been increased by more than 10% (single module)
• Greater heat exchange efficiency
New shape New angle
Split left-right Improved angle
heat exchanger Σ shape! of the curve
Current model (single module) New single medium & Large cabinet Current model (single module) New single medium & Large cabinet
3) FAN POWER
• Improvement of airflow volume by 23% (single module)
• Energy consumption in the driving shaft has decreased by 20% on average
Expansion of air outlets Improvement in bell-mouth
Longer
Less short
circuit !!
1,211mm
Air volume area: 4,403cm2 1,210mm
Air volume area: 6,334cm2
temp (°C)
consumption indoor
-39% temperature
time (hr)
OUTDOOR UNITS
Actual example of the new compressor control
15.0 15.0
10.0 10.0
Energy Consumption Loss
5.0 5.0 Smoother operation
Power Power
(kW) (kW)
0 0
60 120 180 60 120 180
Time(mm) Time(mm)
Room Temperature(°C) Room Temperature(°C)
Power(kW) Power(kW)
due to frequent
switching on/off -39%
operation energy consumption
27 28
SET FREE Σ outdoor units are compact, lightweight and easily transportable; designed to make life easier for the
New Current New Current
people who specify, install and service them. Offering a wide choice of capacities with compact and flexible piping
options, each unit can be connected to up to 64 indoor units. 1,210mm 1,210mm
1,920mm 2,160mm
COMPACT
High Efficiency - FSNP series
Space Weight New
-14%
New Current
-15%
on average
Current
2,830mm on average
3,410mm
New
Current
New Current
-11% Current 1,210mm
1,920mm
-16%
on average
1,210mm
2,160mm
on average
2,830mm
3,410mm
New
Current
New
New
Current
Current
-37% New Current New Current
-17%
1,210mm Weight
1,210mm 2,830mm Weight
2,830mm
3,630mm
1,920mm
-30% 2,160mm 3,410mm
-20%
Space:1.47m2 0.93m2 Space:2.61m2 2.16m2
Weight:445kg 311kg Weight:850kg 676kg
New Current
Smaller Lighter 2,830mm
Lift 3,630mm Crane
Can be transported in an elevator 2,830mm
800mm New package design to be craned
High Efficiency - FSNP series: 3,410mm more easily
14HP class(40.0kW)
Standard - FSNS series:
18HP class(50.0kW)
New Current
2,830mm 1,210mm
765mm
3,630mm
1,350mm
15.0°C 15.0°C
0
0
OPERATION TEMPERATURE RANGE
DB DB WB DB DB WB
52.0°C 52.0°C
48.0°C 48.0°C
15.0°C 15.0°C
0
0
-5.0°C -5.0°C
-10.0°C -10.0°C
-20.0°C -20.0°C
NOTES: 52.0°C
*Refer to the technical catalog for the detail. 48.0°C
** There are some conditions for “Low Ambient Setting”. Refer to the technical catalogue for the detail, and, consult your dealer in inquiry.
0
0
-5.0°C -5.0°C
IDU COMBINATIONS RANGE
OUTDOOR UNITS
Expansion of number of connectable indoor units Up to
130%
Standard - FSNS series
Range of Combination Capacity 50-150%: High Efficiency Type (FSNP series)(5-54HP class)
50-130%: High Efficiency Type (FSNP series)(56-72HP class) & Standard Type (FSNS series)
Recommended Connectable 5 5 8 10 10 16 16 18 20 26 26 32 32 32 32 32 38 38
Indoor Units Q'ty
NOTES:
1. T
he connectable indoor unit capacity ratio can be calculated as follows. Connectable Indoor Unit Capacity Ratio=Total Indoor Unit Capacity/Total Outdoor Unit Capacity
2. F or the system under which all the indoor units are supposed to operate simultaneously, the total indoor unit capacity should be less than outdoor unit capacity. Otherwise, it may cause a
decrease of operating performance and operating limit in overload operation.
3. F or the system under which all the indoor units are not supposed to operate simultaneously, the total indoor unit capacity is available up to 130% (or 150%) against the outdoor unit capacity.
4. W
hen operating the outdoor unit in cold areas with temperatures of -10.0°C, or under the high heating load conditions, the total indoor unit capacity should be less than 100% against the outdoor
unit capacity and the total piping length should be less than 300 metre.
5. T
he air flow volume for indoor units of 0.8 and 1.0HP class is set higher than that for indoor units of 1.5HP class or more. Make sure to select appropriate indoor units when installing indoor units
where cold draft may occur during heating operation. If installing indoor units in such places, refer to the recommended number of connectable indoor units.
6. F or connecting Tempclean Indoor Unit and Outdoor Air Processing Air Conditioner, the number of the indoor units should be within recommended connectable indoor units number.
7. If combination capacity of indoor units exceed 100% of outdoor unit capacity, there might be the possibility of insufficient capacity of 130% (High Efficiency Type (FSNP series) (56-72HP class)/
Standard type (FSNS series)) and 150% (High Efficiency Type (FSNP series)(5-54HP class)) combination ratio. Refer to the technical catalog for the detail. If combination capacity exceed 130%(High
Efficiency - FSNP series: 56-72HP class & Standard - FSNS series) or 150%(High Efficiency - FSNP series: 5-54HP class) contact your distributer or dealer.
29 30
High static pressure for outdoor units: New Model 4 Options available
Wall
can handle up to 80Pa 0Pa 30Pa 60Pa 80Pa
Between 1st branch Multi Kit and the farthest IDU 90m Between IDUs 30m
Notes:
1. Please consult your distributor if your required system is over the recommended connectable number of indoor units.
2. Maximum level difference between ODU and IDU (ODU above IDU) for 56-72HP class (High Efficiency - FSNP series) & 56-96HP class (Standard - FSNS series) is 90 metre.
Longer piping (up to 110 metre) is available for up to 54HP class only.
3. Your contact to distributor is required when maximum level different between ODU and IDU is over 50 metre (ODU above IDU) / 40 metre (IDU over ODU).
Example: Example:
∙ 26-36 HP class (FSNP series) Piping connection kit ∙ 56-72 HP class (FSNS series) Piping connection kit
∙ 26-48 HP class (FSNS series) MC-NP21SA1 MC-NP31SA
Multi kit
Up to 110m*
30m
30m
Multi kit
90m 90m
165m 165m
(Actual) Gas side Liquid side (Actual)
Supported by
110m
Name: G1TOWER
Address: 1070 Ichige, Hitachinaka-shi, Ibaraki Prefecture(in Mito Works)
Land area: 388m2
Building size: 213.5m above ground, 15m below ground
Floors: Nine above ground, one below ground
Owner: Building Systems Business Unit; Hitachi, Ltd.
http://www.hitachi.com/businesses/elevator/about_us/g1tower/
110m
SET FREE Σ
Air Source Heat Pump type
High Efficiency - FSNP series
31 32
open
BUILT TO PERFORM
OUTDOOR UNITS
Rotation
on on off on off on
Oil separator
Accumulator
Compressor
ANTI-CORROSION
Oil return port
• Optional anti-corrosion treatment improves reliability in
Pressure
coastal environments equalization port
33 34
• The lower part of heat exchanger uses sub-cooling refrigerant that prevents frost and ice formation to
provide continuous heating
• For the comfort of your building occupants, indoors unit fans are stopped during defrosting so that no
cold air is blown on those inside
• The maximum defrosting interval is now 250 minutes
–
Please refer to the Technical Catalog for more
information on defrosting technology.
image
frosting
cold
warm
No Frost!
hot
More efficient
Room
Temperature
Heating
Power
Heating duration
more than 200%
longer
Time Time
on off on off on
A location that is not exposed to sea A place that is susceptible to sea breezes
breezes, but that appears to be suitable (But the device is not directly exposed to
ODU ODU
Installation
ODU ODU
OUTDOOR UNITS
(3) Okinawa and remote islands
Resistance to salt damage Resistance to heavy salt damage
(1) Please install the device in a location that avoids direct sea water splashes and sea breezes as much as possible.
∙Please install the device on the leeward side of a building.
∙If you have to install a device on the side of the beach, please avoid exposing it to direct sea breezes by erecting a wind-protective board.
∙Please be careful about the direction of installation. (The degree of corrosion differs depending on whether a device is installed parallel to the coastline or perpendicular
to the coastline.)
(2) Please ensure that any sea salt particles that adhere to the exterior panels will be washed away by the rain.
(3) Because the pooling of water on the bottom base of the outdoor unit significantly boosts the corrosion effects, please be careful about the inclination so that the ability
for water to run through the bottom base of an outdoor unit will not be affected.
(4) For a device installed in a beach area, please rinse it with water on a regular basis to remove all salt adhering to the device.
(5) Please install the device in a location where water drains away well. In particular, please secure the drainage of the foundation parts.
(6) Please be sure to repair any scratches that are created during the installation and maintenance work.
(7) Please inspect the conditions of the device on a regular basis. (If necessary, please apply anti-rust treatments or replace parts.)
*If you install the device in a special atmosphere, you will need to undertake sufficient special consideration.
Units that are resistant to salt damage are based on the “Standard of Testing Resistance to Salt Damage of Air Conditioning Devices JRA9002” of the Japan Refrigeration and Air
Conditioning Industry Association (JRAIA).
35 36
37 38
HP Class 5 6 8 10 12 14
Weight Net Weight 400V/50Hz kg 190 190 255 259 260 270
380-415V/50Hz
380V/60Hz
Quantity 1 1 1 1 1 1
Quantity 1 1 2 2 2 2
Air Flow Rate m3/min. 150 170 185 219 219 243
Main Refrigerant Liquid Line mm φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 φ12.7
Piping
Heat Pump Gas Line mm φ15.88 φ19.05 φ19.05 φ22.2 φ25.4 φ25.4
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve
Quantity 2 2 2 2 2
Quantity 2 2 4 4 4
Notes:
1. T
he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre (RAS-16~18FSNP) Piping Length: 7.5 metre (RAS-16~18FSNP)
10.0 metre (RAS-20~24FSNP) 10.0 metre (RAS-20~24FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
xcept for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. T
he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
39 40
HP Class 26 28 30 32 34 36
Weight Net Weight 400V/50Hz kg 259+345 260+345 260+360 270+360 345+360 360+380
380-415V/50Hz
380V/60Hz
Quantity 3 3 3 3 4 4
Quantity 4 4 4 4 4 4
Air Flow Rate m3/min. 219+326 219+326 219+362 243+362 326+362 362×2
Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping
Heat Pump Gas Line mm φ31.75 φ31.75 φ31.75 φ31.75 φ31.75 φ38.1
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre (RAS-26~30FSNP) Piping Length: 10.0 metre (RAS-26~30FSNP)
12.5 metre (RAS-32~36FSNP) 12.5 metre (RAS-32~36FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
OUTDOOR UNITS
Refrigerant Type R410A
Quantity 3 3 3 4 4
Quantity 6 6 6 6 6
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 12.5 metre (RAS-38~44FSNP) Piping Length: 12.5 metre (RAS-38~44FSNP)
15.0 metre (RAS-46FSNP) 15.0 metre (RAS-46FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
41 42
HP Class 48 50 52 54
Quantity 5 5 6 6
Quantity 6 6 6 6
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre Piping Length: 15.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
OUTDOOR UNITS
Refrigerant Type R410A
Quantity 5 5
Quantity 8 8
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre (RAS-56FSNP) Piping Length: 15.0 metre (RAS-56FSNP)
17.5 metre (RAS-58FSNP) 17.5 metre (RAS-58FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
43 44
HP Class 60 62
Quantity 6 7
Quantity 8 8
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre Piping Length: 17.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
OUTDOOR UNITS
Refrigerant Type R410A
Quantity 8 8 8 8 8
Quantity 8 8 8 8 8
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre Piping Length: 17.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
45 46
HP Class 8 10 12 14 16 18
Weight Net Weight 400V/50Hz kg 190 190 210 268 310 311
380-415V/50Hz
380V/60Hz
Quantity 1 1 1 1 2 2
Quantity 1 1 1 2 2 2
Air Flow Rate m3/min. 165 170 190 239 256 256
Main Refrigerant Liquid Line mm φ9.52 φ9.52 φ12.7 φ12.7 φ12.7 φ15.88
Piping
Heat Pump Gas Line mm φ19.05 φ22.2 φ25.4 φ25.4 φ28.58 φ28.58
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
OUTDOOR UNITS
Compressor Type Hermetic (Scroll)
Quantity 2 2 2
Quantity 2 2 2
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre Piping Length: 10.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
47 48
HP Class 26 28 30 32 34 36
Weight Net Weight 400V/50Hz kg 210+268 210+310 210+311 268+311 310+311 311+311
380-415V/50Hz
380V/60Hz
Quantity 2 3 3 3 4 4
Quantity 3 3 3 4 4 4
Air Flow Rate m3/min. 190+239 190+256 190+256 239+256 256×2 256×2
Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping
Heat Pump Gas Line mm φ31.75 φ31.75 φ31.75 φ31.75 φ31.75 φ38.1
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre (RAS-26~30FSNS) Piping Length: 10.0 metre (RAS-26~30FSNS)
12.5 metre (RAS-32~36FSNS) 12.5 metre (RAS-32~36FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
Weight Net Weight 400V/50Hz kg 268+365 311+364 311+365 364+364 364+365 365+365
380-415V/50Hz
380V/60Hz
OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve
Quantity 3 4 4 4 4 4
Quantity 4 4 4 4 4 4
Air Flow Rate m3/min. 239+348 256+329 256+348 329×2 329+348 348×2
Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping
Heat Pump Gas Line mm φ38.1 φ38.1 φ38.1 φ38.1 φ38.1 φ38.1
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 12.5 metre (RAS-38~44FSNS) Piping Length: 12.5 metre (RAS-38~44FSNS)
15.0 metre (RAS-46~48FSNS) 15.0 metre (RAS-46~48FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
49 50
HP Class 50 52 54
Quantity 5 6 6
Quantity 6 6 6
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre Piping Length: 15.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
Weight Net Weight 400V/50Hz kg 268+311+365 311+311+364 311+311+365 268+365+365 311+364+365 311+365+365
380-415V/50Hz
380V/60Hz
OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve
Quantity 5 6 6 5 6 6
Quantity 6 6 6 6 6 6
Air Flow Rate m3/min. 239+256+348 256+256+329 256+256+348 239+348+348 256+329+348 256+348+348
Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping
Heat Pump Gas Line mm φ44.45 φ44.45 φ44.45 φ44.45 φ44.45 φ44.45
System (2 Pipes)
Notes:
1. T
he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre (RAS-56FSNS) Piping Length: 15.0 metre (RAS-56FSNS)
17.5 metre (RAS-58~66FSNS) 17.5 metre (RAS-58~66FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
xcept for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. T
he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
51 52
HP Class 68 70 72 74 76 78
Weight Net Weight 400V/50Hz kg 364+364+365 364+365+365 365+365+365 268+311+311+365 311+311+311+364 311+311+311+365
380-415V/50Hz
380V/60Hz
Quantity 6 6 6 7 8 8
Quantity 6 6 6 8 8 8
Air Flow Rate m3/min. 329+329+348 329+348×2 348×3 239+256×2+348 256×3+329 256×3+348
Main Refrigerant Liquid Line mm φ22.2 φ22.2 φ22.2 φ22.2 φ22.2 φ22.2
Piping
Heat Pump Gas Line mm φ44.45 φ44.45 φ44.45 φ50.8 φ50.8 φ50.8
System (2 Pipes)
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre (RAS-68~72FSNS) Piping Length: 17.5 metre (RAS-68~72FSNS)
20.0 metre (RAS-74~78FSNS) 20.0 metre (RAS-74~78FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
Weight Net Weight 400V/50Hz kg 268+311+365+365 310+311+365+365 311+311+365+365 268+365+365+365 310+365+365+365 311+365+365+365
380-415V/50Hz
380V/60Hz
OUTDOOR UNITS
Refrigerant Type R410A
Quantity 7 8 8 7 8 8
Quantity 8 8 8 8 8 8
Air Flow Rate m3/min. 239 + 256 + 348 × 2 256 + 256 + 348 × 2 256 × 2 + 348 × 2 239 + 348 × 3 256 + 348 × 3 256 + 348 × 3
Main Refrigerant Liquid Line mm φ22.2 φ22.2 φ22.2 φ22.2 φ22.2 φ25.4
Piping
Heat Pump Gas Line mm φ50.8 φ50.8 φ50.8 φ50.8 φ50.8 φ50.8
System (2 Pipes)
Notes:
1. T
he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 20.0 metre (RAS-80~84FSNS) Piping Length: 20.0 metre (RAS-80~84FSNS)
22.5 metre (RAS-86~90FSNS) 22.5 metre (RAS-86~90FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
xcept for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. T
he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
53 54
HP Class 92 94 96
Quantity 8 8 8
Quantity 8 8 8
Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 22.5 metre Piping Length: 22.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
55 56
HP class Connectivity
Number
FSNP series FSNS series
MC-NP20SA1 20-24 - 2 for Gas: 1 Branch Pipe for Gas Line Branch Pipe for Liquid Line
for Liquid: 1
MC-NP21SA1 26-36 26-48 2
MULTI-KIT
Branching for indoor and outdoor connecting pipes Example: MW-NP282A3
Line branch
First branching pipes
MW-NP282A3 5-10
MW-NP452A3 12-16
Gas Side Liquid Side
MW-NP692A3 18-24
MW-NP902A3 26-54
MW-NP2682A3 56-96
≥ 90 Φ50.8 Φ25.4
Header branch
MH-NP288A 5-10 8
16-24 20-36 2
26-32 38, 40 3
34, 36 42-48 4
Drain Boss×2 Drain Cap×2
38-42 50-54 3 To close the drain hole
44, 46 56-60 4
48, 50 62-66 5
52, 54 68-72 6
56, 58 74-78 5
60 80-84 6
62 86-90 7
64-72 92-96 8
CABINET COVER
Air inlet grille Image Left Side
OUTDOOR UNITS
HP class (kW) Rear Right Left
Stainless
57 58
65 Cassette
65 4-way cassette type(RCI-FSN3)
66 4-way cassette compact type
67 2-way cassette type
69 Ducted
70 High esp (external static pressure) type
71 Medium esp (external static pressure) type
72 Slim type
73 Compact type
(both AC motor type and DC motor type available)
74 Larger air volume type
81 Ventilation
81 Total heat exchanger
82 All fresh air unit
59 60
Indoor Unit Category Cooling (kW) 1.6 1.7 2.2 2.3 2.8 2.9 3.6 3.8 4.0 4.4 5.0 5.6 6.3 7.1 8.0 8.4 9.0 11.2 14.0 14.2 16.0 18.0 22.4 28.0
SLIM TYPE • • • •
COMPACT TYPE
(BOTH AC MOTOR TYPE AND
• • • • • • • •
DC MOTOR TYPE AVAILABLE)
FLOOR/CEILING • • • • • • • •
CONVERTIBLE TYPE
Fan Air Flow Rate (m3/h) 200 300 400 500 650 800 1,000 1,080 1,250 1,500 1,680 2,000 2,100 2,500 3,000 4,000 5,000 6,000
–
FREEDOM OF CHOICE
Because no two spaces are ever quite Color Options
the same, your Hitachi VRF system is Available units: 4-Way, 2-Way, 1-Way Cassettes
Available colors: White, Black, Beige, Grey
customizable with additional features
that work in complete harmony with Motion Sensor
your design. For extra efficiency, wide angle motion sensors can be included with the
following indoor units:
Available units: 4-Way, 4-Way Compact, 2-Way and 1-Way Cassettes,
Ducted High ESP, Ducted Medium ESP, and Ceiling Suspended units
4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE 2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE
∙ You can distribute air over longer ∙ Made to give you greater design ∙ Motion sensor available for better ∙ Motion sensor available for better
distances with individual four-way flexibility as the dimensions fit energy saving operation energy saving operation
louvers that can accommodate 600mm×600mm architectural ∙ Ideal for a higher ceiling location ∙ Optimum air flow conditions are
optional duct flanges module ceiling specifications for installation (up to 4.6m in created by either downward air
∙M otion sensor available for better ∙ Quiet operation level (as low as cooling mode) discharge or frontal air discharge
energy saving operation 24.5dB(A)) ∙ Individually operated louvers give (via optional grille)
∙ I deal for a higher ceiling location ∙ Wide range of air flow rate ideal for room occupants more comfort or a combination of both
for installation high ceiling installation with 4.6m ∙ Quiet operation level (as low as ∙ Quiet operation level
(up to 5.5m in cooling mode) air blow down in cooling mode 27dB(A)) (as low as 27dB(A))
∙S etback temperature control ∙ Setback temperature control ∙ Setback temperature control ∙ Setback temperature control
available, leading to better available, leading to better available, leading to better available, leading to better
operation operation operation operation
DUCTED
HIGH ESP TYPE MEDIUM ESP TYPE SLIM TYPE COMPACT TYPE LARGER AIR VOLUME TYPE
∙ High external static pressure ∙ 3 steps of static pressure ∙Ideal for narrow ceiling voids (BOTH AC MOTOR TYPE AND ∙ Two external static pressure
available: Up to 200Pa for RPI-2.0- (50/100/150 Pa) available installation thanks to low height DC MOTOR TYPE AVAILABLE) settings for better flexibility
6.0FSN3 model, up to 230Pa for ∙ You have more design flexibility up to 192mm & width just 700mm ∙ Ideal for installation over the ∙ High external static pressure:
RPI-8.0/10.0FSN1 model with both rear and bottom air ∙Drain-pump with 900mm lift as closet or windows thanks to Up to 120Pa (140Pa in 7HP class)
∙ Y ou have more design flexibility suction directions available standard optional part the up to the compactness with ∙ Suitable for air distribution for
with both rear and bottom air ∙ Setback temperature control ∙Quiet operation level (as low as 192mm height multiple zone
FLOOR CONCEALED TYPE FLOOR EXPOSED TYPE FLOOR/CEILING CONVERTIBLE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
∙ When there is no ceiling void, ∙ Easy installation ∙ Each unit can be floor mounted or ∙ Ideal for a higher ceiling ∙ Simple installation procedure
this unit gives you a minimal, ∙ Little installation space required, ceiling suspended (up to 5.6m in cooling) ∙ Flexible discreet design suitable
low visibility option as it can be with only 220mm depth ∙ Easy installation ∙ Better power-saving with optional for any interior
installed in floor cavities and walls ∙ Suitable for installation under a ∙ Fresh air-intake design Motion Sensor ∙ Without expansion-valve model
∙ L ittle installation space required, window, with a 630mm height ∙ Optional drain pump available ∙ Quiet operation level available for 0.6-1.5 for more silent
with only 220mm depth (as low as 28dB(A)) indoor space
∙S uitable for installation under a ∙ Setback temperature control ∙ Setback temperature control
window, with a 620mm height available, leading to better available, leading to better
operation operation
VENTILATION
61 62
OPTIONAL Receiver Kit for wireless remote controller PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHZ1
ACCESSORY
Drain-up mechanism availability • (*3) • (*3) • (*3) • (*3) • (*3)
0.5°C/1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 0.5°C/1.0°C 0.5°C/1.0°C
4 taps 3 taps 3 taps 6 taps 3 taps 3 taps 3 taps 3 taps 4 taps 4 taps
• • • • • • • • • •
• • • • • • • • • •
• •
• • •
• • •
• • •
• • •
• • • • • • • • • •
• • •
• • •
• • • • • • • • • •
• • •
SOR-NEZ SOR-NEP
PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHP1 PC-ALHZ1
• (*7)
F-280LI KW-PP5Q KW-PP5Q • (*8)
• (*8)
• (*8)
• (*8) • (*8)
B-280LI KW-PP6Q KW-PP6Q
MSF-NP63A1
MSF-NP112A1
MSF-NP36AH1
(*1) This function is utilized to prevent cold discharged air at start-up of heating operation, after (*5) 5 steps only in the operation of Cooling or Dry.
defrosting operation, etc. The fan speed automatically switches from Slow to Low and then to (*6) 3 colors available except white (Beige, Grey and Black).
the set fan speed. The fan operation might be stopped for up to 2 minutes. At this time the
louver is fixed horizontally. (*7) Optional parts: Duct Adapter is available. please consult your distributor.
(*2) Advanced wired remote controller PC-ARF1 needs to be connected. (*8) Please consult your distributor for the availability.
63 64
Decoration panel With Motion Sensor P-AP160NAE T-Pipe Connection Kit TKCI-160K
Without Motion Sensor P-AP160NA1 Kit for Deodorant Filter 1.0-2.5 (HP Class) F-71L-D1
Receiver kit Advanced PC-ALH3 & Filter set 3.0-6.0 (HP Class) F-160L-D1
Duct Adapter PD-75A Kit for Deodorant Filter & Filter Box B-160H2
Fresh Air Intake Kit OACI-160K2 Antibacterial Long-life Filter F-160L-K
3-Way Outlet Parts Set PI-160LS1
Notes:
1. The
cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
65 66
Decoration panel 0.8-3.0 (HP Class) P-AP90DNA Antibacterial 0.8-3.0 (HP Class) F-90MD-K1
4.0-6.0 (HP Class) P-AP160DNA Long-life Filter 4.0-6.0 (HP Class) F-160MD-K1
Receiver kit PC-ALHD1 Filter Box 0.8-3.0 (HP Class) B-90HD
Motion Sensor SOR-NED 4.0-6.0 (HP Class) B-160HD
Duct Adapter PD-150D
Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
Adaptable Panel Model P-AP36CNA (for RCS-[0.8-1.0]FSN) P-AP56CNA (for RCS-[1.5-2.0]FSN) P-AP80CNA (for RCS-[2.5-3.0]FSN)
Color Neutral White Neutral White Neutral White
Outer Height mm 35 35 35
Dimensions Width mm 1,100 1,100 1,410
Depth mm 800 800 800
Net Weight kg(lbs.) 4.5(9.9) 4.5(9.9) 6(13.2)
Approximate Packing Measurement m3 0.098 0.098 0.125
Decoration panel 0.8-1.0 (HP Class) P-AP36CNQ Drille for Front Discharge 0.8-2.0 (HP Class) DG-56SW1
1.5-2.0 (HP Class) P-AP56CNA 2.5-3.0 (HP Class) DG-80SW1
2.5-3.0 (HP Class) P-AP80CNA Air Outlet Shutter Plate 0.8-2.0 (HP Class) PIS-56LS
Receiver kit PC-ALHS1 2.5-3.0 (HP Class) PIS-80LS
Motion Sensor SOR-NES
Duct Adapter PD-100
Notes:
1. The
cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
67 68
Receiver kit Advanced PC-ALHZ1 Filter Box for 0.8-2.0 (HP Class) B-56LI
Motion Sensor SOR-NEZ Long-Life Filter 2.5-3.0 (HP Class) B-90LI
Condensate Drain Pump Kit - (included as standard equipment) 4.0-6.0 (HP Class) B-160LI
Antifungal Long-Life Filter 0.8-2.0 (HP Class) F-56LI Long-Life Filter Kit/ 8-10 (HP Class) F-280LI
2.5-3.0 (HP Class) F-90LI Long-Life Filter
4.0-6.0 (HP Class) F-160LI MotioFilter Boxn Sensor 8-10 (HP Class) B-280LI
Notes:
1. The nominal cooling capacity is the combined capacity of the Hitachi standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return
Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V. The above data was measured in an anechoic chamber
so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting (High Pressure Setting1 - High Pressure Setting2)” values
when a filter is not used. The sound pressure level is based on the Standard Pressure Setting.
Receiver kit Advanced PC-ALHZ1 Filter Box for 0.8-2.0 (HP Class) B-56LI
Motion Sensor SOR-NEZ Long-Life Filter 2.5-3.0 (HP Class) B-90LI
Condensate Drain Pump Kit - (included as standard equipment) 4.0-6.0 (HP Class) B-160LI
Antifungal Long-Life Filter 0.8-2.0 (HP Class) F-56LI
2.5-3.0 (HP Class) F-90LI
4.0-6.0 (HP Class) F-160LI
Notes:
1. The nominal cooling capacity is the combined capacity of the Hitachi standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return
Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V. The above data was measured in an anechoic chamber
so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting (High Pressure Setting1 - High Pressure Setting2)” values when
a filter is not used. The sound pressure level is based on the Standard Pressure Setting.
69 70
Notes:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting values when a filter is not used.
71 72
Notes:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting values when a filter is not used.
Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Voltage
of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2 dB(A). The data
in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*1) indicates “High Pressure Setting (Standard Pressure Setting)” values when a filter is not used. The sound pressure level is
based on the Standard Pressure Setting.
73 74
Cavity that
conceals
Blends unobtrusively with any interior décor: only the suction and the unit
discharge grilles are visible.
Its low height (only 620mm) enables the unit to fit perfectly beneath
620mm
a window.
Requires little installation space thanks to its slim 202mm depth.
900-1,170mm
Air Inlet
202mm
Notes:
1. The cooling and heating capacities above show the maximum capacities when outdoor and indoor temperatures are under the following conditions:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on the following conditions:
1 metre from the unit.
1 metre from floor level.
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber.
Reflected sound should be considered prior to installation
–
For full specifications, please refer to the Technical Catalog.
Design Flexibility
Notes:
1. T
he cooling and heating capacities above show the maximum capacities when outdoor and indoor temperatures are under the following conditions:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure level is based on the following conditions:
1 metre from the unit.
1 metre from floor level.
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber.
Reflected sound should be considered prior to installation
–
For full specifications, please refer to the Technical Catalog.
75 76
⟦CEILING USE⟧ ⟦FLOOR USE⟧ Equipped with air-intakes, the unit connects
Supplies air to a wide area. Smaller footprint: Only 230mm in depth. with ventilations such as a Total Heat
Exchanger using a duct, providing better
High ceiling use capability. Suitable for installation beneath a window
interior air quality.
thanks to the 680mm height.
Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.0 metre Beneath the unit.
1.0 metre from Discharge grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.
Notes:
1. T
he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
he sound pressure level is based on following conditions.
1.0 metre Beneath the unit.
1.0 metre from Discharge grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.
77 78
2019/06/14 14:51
–
VENTILATION
Notes:
(*1):KPI-10021 has different units according to the applied power supply, 220-240V/50Hz and 220V/60Hz.
(*2):The sound pressure level is based on following conditions.
1.5 metre beneath the unit and this data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
(*3):The noise at the air outlets is the values at a 45° angle, 1.5 metre in front of the unit.
(*4):The sound pressure level is based on the total heat exchange mode.
In case of the bypass ventilation mode, the sound pressure level increase by approximately 1 dB(A).
8. W
hen outdoor temperature is below 20.0°C in cooling operation, the system will be automatically converted to ventilation operation.
When outdoor temperature is higher than 15.0°C in heating operation, it will be automatically converted to ventilation operation. When lower than -7.0°C, the
fresh air processing unit will stop running.
81 82
CONTROLLERS
93 Centralized controllers
94 Line up overview
95 CENTRAL STATION mini
97 CENTRAL STATION EZ
99 CENTRAL STATION EX
103 CENTRAL STATION NT
105 CENTRAL STATION PSC-A64S
106 CENTRALIZED ON/OFF CONTROLLER PSC-A16RS
107 H-LINK
109 Others
109 BMS ADAPTER For BACnet® HC-A64BNP1
BMS ADAPTER for LONWORKS® HARC70-PE1
110 BMS ADAPTER for LONWORKS® HARC-BXE
111 7 DAY TIMER PSC-A1T
112 3P CONNECTOR CABLE PCC-1A
REMOTE SENSOR THM-R2A
REMOTE CONTROL CABLE PRC-5K, 10K, 15K
83 84
85 86
Operation Mode
Indicator Setting
Temperature
Indicator
Operation Guide
Indicator
Run/Stop Switch
2 RC
control is ........
available
Up to 16 IDU
H-LINK
Primary RC Secondary RC Transition wiring is necessary Remote Control Cable
FUNCTIONS
Setting Run/Stop Screen Screen Adjustment Management Operation Lock/Set
Operation Mode Language Main/Sub Control
Auto Mode Setting Temperature Unit_°C Built-in-Timer (On/Off)
Temperature Setting Adjusting Brightness of Run Indicator Adjusting Date/Time Setting
Temperature Setting Rate_0.5°C /1.0°C Check Menu Sensor Condition Check Thermometer Indication
Fan Speed_3/4/6 Taps Sensor Data Check Power- With Motion Sensor Kit
Saving
Louver Direction Model Display ODU Capacity Control
• Peak Shaving Control
Individual Louver Setting Indoor/Outdoor PCB Check
• Propoer Limit Control
Remote Control Primary-Secondary Setting Self Checking
Indoor Unit Rotation Control
In Use of Ventilation Alarm History Display
Total-Heat- Automatic Fan Operation
Total Heal Exchanger Setting Test Run Test Run
Exchanger Auto Recovery of Temperature
Function Selection
Function Automatic Restart with Upper Limit for Heating Operation
(Optional Function Setting)
Selection Eco-operation
Thermistor Selection Lower Limit for Cooling Operation
Automatic Reset Temperature
(Cooling/Heating) Input/Output Setting Power Consumption Visualization
Service Filter Sign Indoor Unit Address Checking Operation Settable Timer Operation Times (per day): 5
Room Name Setting Compressor Pre-Heat Control Cancellation ODU Noise Reduction Schedule
CONTROLLERS
Away Function
A Returning to set
30.0°C
temperature when
C room key inserted
27.0°C
B D
23.0°C
87 88
POWER-SAVING FUNCTION
Standard operation for a room Moderate operation for a room More moderate operation if It is also possible to stop
with a lot of human movement. with little human movement. people are absent for a certain the operation of the unit by
period of time. applying a particular setting if
people remain absent for more
than 30 minutes.
Operation Time
Time
Time
Time
After a certain time passes, the changed temperature returns to the set
point. The time can be selected from four options (15‑30‑60‑90 mins).
CONTROLLERS
In Case of Restaurant in
Cooling Mode
ADAPTABILITY
sub RC.
* Operation Mode
* Setting Temperature
Main RC Sub RC Sub RC Sub RC
89 90
FUNCTIONS
Setting Run/Stop Check Menu Sensor Condition Check Management Operation Lock-Set
Operation Mode Sensor Data Check Lower Limit for Cooling Operation
Auto Mode Setting Test Run Test Run Upper Limit for Heating Operation
Temperature Setting Function Selection Built-in Timer (On/Off)
Temperature Setting Rate_1.0°C (Optional Function Setting) Schedule Weekly Schedule (+PSC-A1T)
Fan Speed_3 Taps Thermistor Selection
Louver Direction Input-Output Setting
Remote Control Primary-Secondary Setting Indoor Unit Address Change
Automatic Reset Temperature Indoor Unit Address Checking Operation
(Cooling/Heating) Indoor Unit Address Initialization
Service Filter Sign Input-Output Setting Initialization
Filter Sign Reset Compressor Pre-Heat Control Cancellation
Elevating Grille
Louver Open/Close
Alarm Sign
FUNCTIONS
CONFIGURATION
H-LINK
Remote Control Cable
CONTROLLERS
CONTROLLER SYSTEMS – INDIVIDUAL
–
RECEIVER KIT
FOR WIRELESS REMOTE
CONTROLLER (PC-AWR)
PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1
For indoor 4-Way 4-Way 2-Way 1-Way Ceiling Ducted Floor Floor Floor/Ceiling Wall
unit model Cassette Cassette Cassette Cassette Suspended Exposed Concealed Convertible Mounted
Compact
–
For more information about options and accessories,
please consult your Hitachi Cooling & Heating channel
partner.
91 92
CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRALIZED
mini EZ EX NT ON/OFF CONTROLLER
Operation Touch screen Touch screen Touch screen PC or touch-panel-PC Button Button
supplied locally
Display Operation panel size options 4 2 7 2 - -
Layout - - • - - -
List options - - 3 - - -
By area - - • - - -
By block • • • • • -
By group - - • • - -
By RC group • • - - • •
By indoor unit - - • • - -
CONTROLLERS
Control Function Main 5 functions (*5) • • • • • - (*6)
Filter sign • • • • • -
Annual/Summer/Winter schedule - - • • - -
Other function Alarm history (records number) 100 100 10,000 500 - -
(*1) One external adapter can control (128 remote controller groups/128 groups/32 blocks), and Central Station EX can connect up to 15 adapters.
(*2) No restriction on the number of H-LINK
(*3) Individual Function Control in Each Remote Controller is not applicable
(*4) Applicable by Schedule function or External Signal input
(*5) Main 5 functions mean 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control
(*6) Only Run/Stop is available
(*7) Alarm Code cannot be displayed, but Operation indicator keeps flashing in red to inform abnormal condition
(*8) Available with 7-day timer (PSC-A1T)
93 94
22 52.7 CAPACITY
RC group 32
Group 32
Block 4 Patterns (2/4/8/16)
Indoor Unit 160
SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Lateral View (mm) Electrical Power Consumption 20W (Max.)
140mm Communication Unit Units of Adopting for H-LINK
Communication Line Non-polar 2-wire
Communication Speed 9,600bps
Wiring Length 1,000m (Total Length)
Display 5.0-inch Wide Color LCD (Full Dot)
Display Control Touch Panel
FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
• RC Operation Prohibited Setting
• Accumulated Operating Time
Most compact in our touch panel centralized • Operation Mode • Setting Fan Speed
controller. Its down-to-detail control • Setting Louver • Filter Sign • Alarm Code”
CS mini
Total 32
RC Groups
H-LINK
Remote Control Cable
In case of classroom
mini
in cooling mode
9:00 ~ 10:00 27 °C Class: on
10:00 ~ 11:00 27 °C Class: on
11:00 ~ 12:00 - °C No class: off
12:00 ~ 13:00 25 °C LUNCH TIME
13:00 ~ 14:00 - °C No class: off
14:00 ~ 15:00 27 °C Class: on
15:00 ~ 16:00 - °C No class: off
16:00 ~ 17:00 27 °C Class: on
17:00 ~ - °C No class: off
[Monitor (Block)]
CONTROLLERS
ON/OFF, "operation mode," "fan speed," "swing louver direction," "setting
temperature," and "prohibition of remote control operation for individual items (run/
stop, operation mode, fan speed, wind direction, setting temperature)"
Energy Saving
Outdoor unit power consumption control by schedule or external signals. Setting temperature range.
95 96
80 CAPACITY
25 55
RC group 64
Group 64
Block 4 Patterns
Indoor Unit 160
170mm Outdoor Unit 64
Building Scale Small - Medium
SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Lateral View (mm)
Electrical Power Consumption 30W (Max.)
250mm
Communication Unit Units of Adopting for H-LINK
Communication Line Non-polar 2-wire
Communication Speed 9,600bps
Wiring Length 1,000m (Total Length)
Display 8.5-inch Wide Color LCD (Full Dot)
Display Control Touch Panel
FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
Easy control with 8.5 inch color touch panel, • RC Operation Prohibited Setting
• Accumulated Operating Time
Its down-to-detail control functionalities, • Operation Mode • Setting Fan Speed
such as Weekly Scheduling, Accumulated • Setting Louver • Filter Sign • Alarm Code
Control Function • Run/Stop* • Fan Speed
Work Hours, etc., help you save energy. Up to • Operation Mode • Louver
64 remote-controlled groups and up to 160 • Temperature Setting
• RC Operation Prohibited
indoor units can be connected to the single air- • Filter Sign Reset
conditioning system. *: “All Groups Run/Stop” command signal exception function for selected groups is
available by “Exception of Run/Stop Operation.” function.
CS EZ
Total 64
RC Groups
H-LINK
Remote Control Cable
CONTROLLERS
Alarm Information
Red color indication: immediate display of malfunction location and cause.
Schedule
Up to 10 actions/day per RC groups can be set as available as auto switch‑off timer.
97 98
(*1) One external adapter can control [160 RC groups / 128 groups / 160 IDUs / 64
372mm ODUs / Each layout], and Central Station EX can connect up to 15 adapters.
Lateral View (mm)
(*2) No restriction on the number of H-LINK
SPECIFICATIONS
SD Rated power supply 100~240VAC ±10% (50/60Hz)
Electrical power consumption 50W (Max.)
FUNCTIONS
Operation All together Schedule Each of the following setting is available in 3 External Energy saving
unit Each area function different [annual] [summer][winter] category input / • Run/Stop
Each block → Weekly schedule output • RC prohibition
Each group → Up to 16 actions can be set per day • Temperature shift
Each RC group → Exception day setting: 5 different types (For Cool/Dry mode: +1.0°C~+9.0°C)
Control On/Off → Holiday setting (For Heat mode: -1.0°C~-9.0°C)
function Mode • Mode shift
Set temperature Setting items in schedule is as below; (Mode shifted to Fan when in Cool/Dry
Fan speed • On/Off mode, and shifted to Stop in Heat mode)
Louver • Operation mode • Capacity control on outdoor units
RC prohibition • Setting temperature • Lower noise control for outdoor units
Filter sign reset • Louver
Function selection for indoor units (*1) • Fan speed Control/Monitor
Function selection for outdoor units (*2) • RC operation prohibition → Controlled items:
Capacity control for outdoor units (*2) • Capacity control for outdoor units • Run/Stop
Lower noise control for outdoor units (*2) • Lower noise control for outdoor units • Mode (Cool/Heat)
History Alarm history: 10,000 records → Monitored items:
Monitor On/Off
External In/Output history: 1,000 records • Run/Stop
function Mode
Pulse input history: 6 months • Mode (Cool/Heat)
Set temperature
• Alarm state
Air intake temperature Management Each of the following data of up to 2 years
RC sensor temperature (*3) report can be shown:
Others
Air intake temperature of outdoor unit visualization • Accumulated operation time (min.)
• Power consumption signal input
Fan Speed • Accumulated thermo-ON time (min.)
• Emergency stop
Louver • Average air intake temp temperature of
RC prohibition indoor unit (*1) Some indoor units may not fully support all functions.
Thermo-ON information • Average air intake temperature of outdoor (*2) It is available for applicable outdoor units only.
Filter sign/Auto cleaning fault unit (*3) There is a case that it cannot be shown in the screen,
Alarm status/Alarm codes • Average setting temperature depending on the remote controller setting.
• Average RC sensor temperature
CONTROLLERS
management and quicker service
maintenance.
• Accumulated operation time
SD
(min.)
• Accumulated thermo-ON time
USB
(min.)
• Average air intake temperature of
indoor unit
• Average air intake temperature of
outdoor unit
• Average setting temperature
• Average RC sensor temperature
(It may not be available
depending on RC settings.)
99 100
1. Panel style
The panel color clearly shows the air conditioner operation mode.
One maximum-sized panel can show the following items with colors
and icons for easy confirmation:
• Room name • Run/stop • Mode • Temperature • Fan speed • Louver
• Air intake temperature (RC sensor temperature or indoor temperature)
• Current status icon
Maximum Minimum
size size
2. Layout style
Upload your own layout images in multiple formats (BMP, JPEG, PNG)
and easily arrange indoor units by dragging them on the touch panel.
Floor view
CONTROLLERS
Normal mode Temperature mode Power consumption mode
101 102
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0
FUNCTIONS
Total RC group -
Connection
Group 128
Capacity
Block 64
Indoor Unit 160
Outdoor Unit 64
Building Scale Medium Large
FUNCTIONS
Display Locally-Supplied PC or Touch-Panel PC
Display Control Locally-Supplied or Touch-Panel
Total Connection Capacity One connected unit Two or three connected units
OS • Windows 7 Home Premium (32 bit/64 bit) • Windows 7 Home Premium (32 bit/64 bit)
• Windows 7 Professional (32 bit/64 bit) • Windows 7 Professional (32 bit/64 bit)
• Windows 7 Ultimate (32 bit/64 bit) • Windows 7 Ultimate (32 bit/64 bit)
• Windows 8 (32 bit/64 bit) • Windows 8 (32 bit/64 bit)
• Windows 8 Pro (32 bit/64 bit) • Windows 8 Pro (32 bit/64 bit)
CPU Intel® Core™2 Duo 1.8GHz or more Intel® Core™2 Duo 1.8GHz or more
(When it is a specific unit, it should be Intel Atom 1.6GHz or more) (When it is a specific unit, it should be Intel Atom 1.6GHz or more)
Memory 1GB or more 2GB or more
Monitor 1,024×768 pixels (Display around 15 inches) 1,024×768 pixels (Display around 15 inches)
1,366×768 pixels (Wide screen display) 1,366×768 pixels (Wide screen display)
1,280×1024 pixels (Display around 17 to 19 inches) 1,280×1024 pixels (Display around 17 to 19 inches)
Browser • Internet Explorer 8 (32 bit) • Internet Explorer 8 (32 bit)
• Internet Explorer 9 (32 bit) • Internet Explorer 9 (32 bit)
• Internet Explorer 10 (32 bit) • Internet Explorer 10 (32 bit)
• Internet Explorer 11 (32 bit) • Internet Explorer 11 (32 bit)
HDD Available Capacity 10GB or more 10GB or more
Interface IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T) or IEEE 802.11 (a/b/g/n) IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T) or IEEE 802.11 (a/b/g/n)
Required Software JavaTM Runtime Environment Version 6 Update 33 JavaTM Runtime Environment Version 6 Update 33
Remarks
• Use a 2 buttons mouse.
• LAN with wake on LAN function or RS-232C Interface is required for UPS.
• The durable period for a management computer may differ from that of air conditioners.
Discuss the updating procedures in advance.
• The required software is included in this product. No preparation is needed.
CS NT CS NT
Internet or LAN
(Ethernet)
H-LINK
Remote Control Cable
LAN(Ethernet)
Off
(Without Lime Green Red Grey
Color)
Icon
Touch the “Icon Guide” and
you can check each icon
description along with the
details.
Filter
The filtering condition
CONTROLLERS
enables you to check the unit
easily and quickly.
103 104
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×120.0×70.5
CAPACITY
RC group 64
120mm Group 64
Block 4 Patterns
Indoor Unit 160
Outdoor Unit 64
FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
120mm • RC Operation Prohibited Setting
• Accumulated Operating Time
• Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code
If your site has a dedicated building manager, the Control Function • Run/Stop* • Fan Speed
Central Station PSC-A64S is suitable for providing • Operation Mode • Louver
convenient monitoring of indoor climates. It controls • Temperature Setting
• RC Operation Prohibited
up to 160 indoor units and up to 8 sub-controllers • Filter Sign Reset
can be connected via H-LINK. In addition to setting *: “All Groups Run/Stop” command signal exception function for selected groups is
the operation mode and temperature, PSC-A64S also available by “Exception of Run/Stop Operation.” function.
SPECIFICATIONS
CAPACITY
RC group 16
120mm
Group 64
Block -
Indoor Unit 160
Outdoor Unit -
FUNCTIONS
Monitor Function • Run/Stop
120mm • Alarm Notification
Control Function • Individual Run/Stop
• Simultaneous All Run/Stop
· Only performs operation/stop control per remote
control group.
CONTROLLERS
· Can be used in combination with the central station.
105 106
WHAT IS H-LINK?
H-LINK is a “Hitachi” original communication system that can be used to control multiple outdoor and indoor units from one control point. Its use
assists installers and service engineers by simplifying commissioning and service maintenance. For building owners and occupants, it provides
outstanding versatility enabling the connection of various types of central control options, enabling better system management. Our proprietary
high-performance communication system enables the connection of control wiring between indoor and outdoor units, and between a centralized
control system and indoor/outdoor units across two or more refrigerant systems.
Basic Wiring
PSC-A32MN
PSC-A32MN
PSC-A32MN
CONTROLLERS
(3) If two systems are completely
separated
verall control is possible by separately
O
connecting the two systems to Point! Point!
“concentrated control.”
It is possible to select a wiring route based
on the wiring distance and the ease of
installation.
PSC-A32MN
PSC-A32MN
107 108
BACnet ®
HC-A64BNP1
–
HARC70-PE1
BMS ADAPTER for LONWORKS®
Bigger Connection Capacity (Up to 128 Indoor Units)
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0
FUNCTIONS
Connection Connection by SNVT
Method to Upper (Standard Network Variable Type)
EXAMPLE OF SYSTEM CONFIGURATION System to LONWORKS® Network
H-LINK Quantity of 8 Remote Control Groups
Remote Control Cable Connection (Max. 128 indoor Units)
LONWORKS® Control Item in • On/Off Order (nviOnOff_ng)
Upper System • Operation Mode Setting (nviMode_ng)
Field-supplied (ng: 0~7) • Temperature Setting (nviSetPoint_ng)
• All On/Off Order (nvi All OnOff)
Monitoring Item • On/Off State & Alarm (nvoOnOff_ng)
Fire in Upper System • Operation Mode State (nvoMode_ng)
Lighting alarm Lift Ventilation
(ng: 0~7) • Temperature Setting (nvoSetPoint_ng)
• Individual Thermostat State (nvoThermo_ng)
• The number of maximum connectable refrigerant systems is
8 (0 to 7). The available setting range of refrigerant system
number and indoor unit addresses is 0 to 15.
LONWORKS®
HARC70-PE1
Field-supplied
Fire
Lighting alarm Lift Ventilation
Central
Controller
LONWORKS®
HARC-BXE
CONTROLLERS
FUNCTIONS
Standard HARC-BXE
Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 64 Indoor Units (8 Indoor Units per 1 PCB)
Control Item in Upper System (n: 0~7) • On/Off Order (nviOnOff_n) • Temperature Setting (nviSetPoint_n) • Operation Mode Setting (nviMode_n)
• All On/Off Order(nviAllOnOff)
Monitoring Item in Upper System (n: 0~7) • On/Off State & Alarm (nvoOnOff_n) • Temperature Setting (nvoSetPoint_n)
• Operation Mode State (nvoMode_n) • Individual Thermostat State (nvoThermo_n)
Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 64 Indoor Units (8 Indoor Units per 1 PCB)
Control Item at Upper System (n: 0~7) • On/Off Order (nviOnOff_n) • Temperature Setting (nviSetPoint_n) • Fan Speed Setting (nviFanSpeed_n)
• Operation Mode Setting (nviMode_n) • All On/Off Order (nviAllOnOff)
• R.C. Sw Permission/Prohibition (nviProhibit_n)
Monitoring Item at Upper System (n: 0~7) • On/Off State & Alarm (nvoOnOff_n) • Inlet Air Temperature (nvoInletTemp_n)
Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 32 Indoor Units (4 Indoor Units per 1 PCB)
Control Item at Upper System (n: 0~3) • On / Off Order (nviOnOff_n) • Fan Speed Setting (nviFanSpeed_n) • Operation Mode Setting (nviMode_n)
• R.C. Sw Permission/Prohibition(nviProhibit_n) • Temperature Setting (nviSetPoint_n)
• All On/Off Order (nviAllOnOff) • Louver Position Setting (nviLouver_n)
Monitoring Item at Upper System (n: 0~3) • On/Off State & Alarm (nvoOnOff_n) • Temperature Setting (nvoSetPoint_n)
• Operation Mode State (nvoMode_n) • Louver Position (nvoLouver_n) • Fan Speed Setting (nvoFanSpeed_n)
• Alarm Code (nvoAlarmDescr_n) • Inlet Air Temperature (nvoInletTemp_n)
• Outlet Air Temperature (nvoOutletTemp_n) • Outdoor Air Temperature (nvoAmbientTemp)
•T
he number of maximum connectable refrigerant system is 8 (0 to 7). The available setting range of refrigerant system number and indoor unit address is 0 to 15.
•A
ll indoor units connected to the PCB need to have same refrigerant system number.
109 110
H-LINK
Remote Control Cable
· By using PSC-A1T with PSC-A64S or PSC-A16RS controllers, the air conditioners
controlled by them can be operated according to a schedule.
· The
timer can be set at 7-day intervals, and operation/stop can be set 3 times daily.
· Remote
control can be prohibited in accordance with the OFF time (when used with
PSC-A64S and PSC-A16RS).
· Two
types of weekly schedule (A and B) can be set, and can easily be changed for
summer and winter.
· The
settings are all digitally displayed, allowing operations and settings to be
checked easily.
· The
power failure backup function prevents the timer from being stopped due to a
power failure lasting up to 2 weeks. «PSC-A1T» «PSC-A64S»
Heating Operation:
Compressor is ON by closing terminals 1 and 2 of CN3 H-LINK
Compressor is OFF by opening terminals 1 and 2 of CN3 Remote Control Cable
–
REMOTE SENSOR
THM-R2A
(To sense the indoor temperature)
EXAMPLE OF SYSTEM CONFIGURATION SPECIFICATIONS
* When the room temperature sensing thermistor
(Remote Sensor) is attached to the auxiliary
Outer Dimensions (H×W×D)
connector, the unit is controlled at average air (mm) 50.0×50.0×15.0
temperature at the indoor inlet and Remote
CONTROLLERS
Sensor point. Length M 8.00
* Not compatible with Wall Type (RPK) indoor unit.
«THM-R2A» H-LINK
Remote Sensor Cord
–
REMOTE CONTROL CABLE
PRC-5K, 10K, 15K
(For PC-ARF1 and PC-AR connection (to IDU))
EXAMPLE OF SYSTEM CONFIGURATION SPECIFICATIONS
111 112
DISTRIBUTOR