Hitachi VRF FSNP FSNS Series - Reduced

Download as pdf or txt
Download as pdf or txt
You are on page 1of 114

SET FREE Σ

VARIABLE REFRIGERANT FLOW SYSTEM


AIR SOURCE HEAT PUMP TYPE
HIGH EFFICIENCY - FSNP SERIES
STANDARD - FSNS SERIES

H4-058_SMZ_HP_ODU_0614.indd 1 2019/06/14 14:46


H4-058_SMZ_HP_ODU_0614.indd 1 2019/06/14 14:46
SET FREE Σ – FSNP & FSNS SERIES
INDEX

Index

03 Welcome

23 Outdoor units

59 Indoor units & ventilation

87 Controllers

01 02

H4-058_SMZ_HP_ODU_0614.indd 2 2019/06/14 14:46



Welcome

Air. It’s a
wonderful thing.

Invisible, silent and life-giving, air makes


our entire world possible. It surrounds us,
continuously energizing, cooling and warming.
It can be unpredictable and sometimes
challenging, but when air is in harmony with us,
everything seems that much easier.

This is our vision.


To create the air that makes life better.

H4-058_SMZ_HP_ODU_0614.indd 3 2019/06/14 14:46


The beauty of balance

No matter what the weather is like outside,


when you’re indoors, you want to have complete
control over your environment. At work or play,

SET FREE Σ – FSNP & FSNS SERIES


awake or asleep, you’re free to create your own
atmosphere; balancing energy with calm, sound
with silence and light with shade. It’s the same
for cooling and heating.

When the air around you is in balance,


you can enjoy life indoors that much more.

Living Harmony

At Hitachi Cooling & Heating we like to think of


this as creating harmony with your interior
environment. When we achieve that wonderful
balance, productivity, learning, happiness
and health can thrive.

We call this ‘Living Harmony’ and it’s at the


center of everything we do.
The future together

Living Harmony puts people first. By balancing


the human needs of our customers with an

WELCOME
uncompromising approach to innovation
and quality, we can continue to create the
technologies for a more comfortable and
balanced world.

Your world. We live in it together.

03 04

H4-058_SMZ_HP_ODU_0614.indd 4 2019/06/14 14:46



Your world
and Hitachi

Change in the air.

Change is one of the few constants in life.


The world around us changes continuously and
as it does, so do our own comfort levels and our
requirements of our buildings.

Creating harmony in the face of change has


always been the driving force behind Hitachi
Cooling & Heating. From maintaining a perfect
indoor climate indoors as the seasons change,
to developing new technology to address the
needs of our changing cities, we’re committed to
solutions that help people adapt to changes today
and in the future.

H4-058_SMZ_HP_ODU_0614.indd 5 2019/06/14 14:46


Design for tomorrow’s
urban spaces.

Space in our cities is under increasing pressure


and as new buildings become more space
efficient, the areas allocated to cooling and

SET FREE Σ – FSNP & FSNS SERIES


heating are shrinking.
We are responding to these changes with a new
generation of space-efficient outdoor units, giving
architects, building managers and owners greater
levels of flexibility.


Learn more about Outdoor Unit
on page 23

Redefining comfort.

Comfort can be felt in a variety of ways, from the


temperature to quietness and even the air flow
itself. Our wide-ranging lineup of indoor units
can meet various comfort requirements. We
offer two different types of ventilation units, and
optional motion sensors are also available for

WELCOME
superior energy saving.


Learn more about Indoor Unit
on page 59

You are in control.

Whether you wish to create a relaxing


atmosphere in your home, improve productivity
at work or manage the energy and maintenance
costs for your building, We gives you the
technology to achieve your goals. From setting
individual climate zones in every room, to
centralized monitoring and reporting for
multiple buildings.


Learn more about Controller
on page 87

05 06

H4-058_SMZ_HP_ODU_0614.indd 6 2019/06/14 14:46



The shape of
things to come

We’ve named our latest


VRF system SET FREE Σ
Continuing the evolution of the SET FREE
series, the sigma symbol (Σ) references the
shape of our revolutionary, ultra-efficient
new heat exchanger.

To learn more about our heat exchanger


technology, please refer to page 81.

H4-058_SMZ_HP_ODU_0614.indd 7 2019/06/14 14:46


07 08

H4-058_SMZ_HP_ODU_0614.indd 8 2019/06/14 14:46



Introducing
Hitachi VRF
SET FREE Σ

Helping you create


perfect indoor balance
The interior spaces where people work, play,
sleep and relax are as individual as they are
and the way they are used is every bit as
unique as their design.

At Hitachi Cooling & Heating, we understand


that everyone needs their own space.
So, wherever you go in the world, we have
a solution to help create and maintain a
perfectly balanced interior environment.

We like to call this balance Living Harmony.

H4-058_SMZ_HP_ODU_0614.indd 9 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
Designing beautiful air For building occupants

WELCOME
The philosophy of Living Harmony shapes Our systems are designed to ensure
everything we do, but it’s really not about us. superior comfort levels by maintaining a
The design of our Variable Refrigerant Flow constant and balanced room temperature.
(VRF) systems starts with truly understanding
the needs of our customers; the people
who use, specify and install our products.

For architects, For building owners,


designers and engineers managers and installers

Modular components offer complete Reduced footprints and lighter, stronger


customization, giving you the freedom materials make our units easy and cost effective
to design environments where people to install, operate and maintain.
can live in total comfort.

09 10

H4-058_SMZ_HP_ODU_0614.indd 10 2019/06/14 14:46


Designed for
flexibility and ease

Well-designed cooling and heating should allow


the best use of indoor and outdoor spaces.
The new SET FREE Σ outdoor units feature an
ultra-compact footprint, so they can be placed
discreetly out of sight or configured to optimize
space usage.

For indoor areas, where we are free to shape our


environment, our extensive line-up of indoor
units gives you the flexibility to design perfect
air in any space, with concealed and compact
units allowing for uninterrupted aesthetics.

Choosing is made simple with intuitive selection


software and of course, our service and after
sales teams are there to assist you at every step.

H4-058_SMZ_HP_ODU_0614.indd 11 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
WELCOME
SET FREE Σ
From Dublin to Dubai, people rely on Hitachi
Cooling & Heating to work more productively, play
and relax in comfort and sleep soundly. That’s
why our “SET FREE” range is designed to perform
faultlessly under the most challenging conditions,
with every component manufactured and tested to
the highest tolerance levels.

Designed for commercial applications, SET FREE Σ


(“sigma”) VRF range sets new standards in reliability
and high efficiency. With an innovative sigma-shaped
heat exchanger, they can operate in a wide range of
climates, from -20.0ºC in heating mode to +52.0ºC in
cooling mode.

11 12

H4-058_SMZ_HP_ODU_0614.indd 12 2019/06/14 14:46


Performance taken
to new levels
Smooth Drive is the world-leading compressor
control technology at the heart of SET FREE Σ.

By calculating the exact amount of refrigerant


required, based on the demands of indoor
units, Smooth Drive manages load operation
efficiently and consistently, creating a more
comfortable, balanced indoor climate in
every part of the building.

H4-058_SMZ_HP_ODU_0614.indd 13 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
Our past shapes
the future
In 1952 a small team of Japanese engineers
set out to realize a unique vision: to help
people around the world create their perfect
indoor environment.

Today, we remain true to our legacy of fine


Japanese design and engineering. Every Hitachi
Cooling & Heating system is designed to perform
reliably with innovative technology that sets the
benchmark for the industry.

This is our commitment to you. Cooling


and heating technologies to help create
your interior Living Harmony.

WELCOME

13 14

H4-058_SMZ_HP_ODU_0614.indd 14 2019/06/14 14:46



Our heritage in
Cooling & Heating

MAIN PRODUCTS
Air Compressor, Roller, Large Split, Refrigerators, Compressor
Casting Casting for refrigeration, Casting

Outdoor unit:
Indoor unit: Large Split controlled
Refrigerator Floor Exposed by built-in
Compressor type (RPF) micro-computer

Japan’s 1st window 1st Large Split system


mounted air conditioner, exported from 1st training Indoor unit: Ceiling
installed in a Kyoto hotel Shimizu to the U.K. school established Suspended type (RPC)
1943

1951
1952

1956

1958

1961

1963

1965

1970
1971
1972
1973

1976

1978
1979

Roller for mill

1st air-cooled Unitary


Shimizu Factory Large Split for export
founded market Outdoor unit:
for low-ambient
temperature
markets
Large casting Hitachi’s 1st Packaged
fan for tunnel AC (Water-cooled
Floor Standing type)

2nd overseas factory


established in Brazil

1st overseas factory


established in Taiwan

H4-058_SMZ_HP_ODU_0614.indd 15 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
Large Split, Refrigerators, VRF, Large Split,
Compressor Compressors

VRF 1ST GENERATION



Hitachi’s first VRF “High-Multi” series with
multiple reciprocating compressors and 5th overseas factory 1st Scroll Compressor 6th overseas factory
individual indoor unit control available opens in the Philippines factory established opens in China
in China

VRF 5TH GENERATION


30HP
VRF 3RD GENERATION – VRF 7TH GENERATION
– Up to 12 indoor units 54HP
Up to 5 indoor units (130% in capacity) –
World 1st IGBT Newly R407C adopted VRF Heat Pump/Heat Recovery
Indoor unit: Ceiling Inverter-driven VRF “SET FREE FSG”: Heat-Pump type compatible modular VRF system
Cassette type up to 115 Hz 1986 “SET FREE FXG”: Heat-Recovery type “SET FREE FSXN”

WELCOME
1981
1982
1983
1984

1986

1988

1990
1991

1996

1999

2003

2005

2011
2012

2016

Indoor unit: Centrifugal VRF:


Wall Mounted an “Outdoor unit”
VRF 2ND GENERATION
type (RPK) made for indoor

5HP 8HP & 10HP installation
Hitachi’s 1st Inverter-
driven VRF with built- VRF 4TH GENERATION
in Scroll Compressor 10 HP

Up to 8 indoor units (130% capacity)
World 1st IGBT built-in Inverter
VRF achieves quietest operation

VRF 8TH GENERATION


Scroll Compressor
96HP
production for

AC unit
Hitachi’s new generation VRF SET
FREE Σ, developed over 33 years in
the industry
VRF 6TH GENERATION
3rd overseas factory 32 HP
opens in Malaysia –
New R410A adopts VRF
“SET FREE FSN”: Heat Pump type
“SET FREE FXN”: Heat Recovery type

15 16

H4-058_SMZ_HP_ODU_0614.indd 16 2019/06/14 14:46



Features &
benefits for
customers

Features, advantages
and benefits at a glance
This table sets out the features and
benefits of the SET FREE Σ range with
your needs in mind.

H4-058_SMZ_HP_ODU_0614.indd 17 2019/06/14 14:46


For architects &
system designers
Your perspective shapes the world
we live in together. Our cooling and

SET FREE Σ – FSNP & FSNS SERIES


heating systems are designed to fit
with your vision.

Superior Performance High ESP: up to 80Pa


•  Cooling EER up to 5.23 & Heating COP up to • Ideal for outdoor units installed indoors
6.19 (High Efficiency - FSNP series) (air ducted)
•  Cooling EER up to 4.54 & Heating COP up to ✓✓ Reduced piping length and costs
5.17 (Standard - FSNS series) ✓✓ Preservation of outdoor environment
✓✓ Smooth Drive ensuring your great
performance in low-load operation Piping flexibility
• Pipe runs up to 1,000m
Outdoor unit compact footprint • Piping level different between ODU and IDU is
• Requires less space than conventional up to 110m for both (ODU above IDU) & (IDU
systems above ODU)
✓✓ Broader choice of installation sites ✓✓ Fits almost all buildings

Night Quiet Mode Outdoor unit modular components


• Three-step sound pressure reduction • Various components can be added or changed
for outdoor units
✓✓ Customization to each project
✓✓ No outdoor noise disturbance

WELCOME
✓✓ Easily updated in case of reconfiguration

Operation temperature range in cooling mode


Ducted systems
• -5.0°C DB to +52.0°C DB
• Accommodates retrofits into existing
(High Efficiency - FSNP series)
duct infrastructure
• -5.0°C DB to +48.0°C DB
• Up to 200Pa High ESP ducted indoor unit
(Standard - FSNS series)
available, flexibility to accommodate short or
✓✓ Suitable for a wide range of climates long duct runs
✓✓ Versatility to minimize refurbishment works
Non-ducted systems
• Makes the most of direct expansion
H-LINK
• Requires less clearance between • Exclusive communication system for central
building floors control
✓✓ Fewer components required • No connection boundary between Hitachi
✓✓ Ideal for historic building renovations Cooling & Heating solutions
✓✓ Flexible wiring routes
Improved Indoor unit/Outdoor unit ✓✓ Easy system optimization
combination ratio
• Up to 150% (High Efficiency - FSNP series) and
130% (Standard - FSNS series)
✓✓ Response to greater load demand

VRF selection software


• Intuitive user experience simplifies and
speeds up design process
✓✓ Allows for confident system specification

17 18

H4-058_SMZ_HP_ODU_0614.indd 18 2019/06/14 14:46


For contractors
& installers
Your skill ensures that our cooling
and heating systems run perfectly.
We design and build them to make
your job easier.

New packaging Robust equipment


• Outdoor unit packaging revised with craning • Improved rigidity ratio of outdoor units
ports addition ✓✓ Extends the service life
✓✓ Friendly for craning
Access for maintenance
Design for convenience • The upper panel (electric box) independently
• Pipes to the outdoor units can be connected detaches from the lower panel (compressor
from the front, back, or underneath chamber)
• Compact and light indoor units for easy • All PCBs are visible, easily accessible and
handling include a 7-segment display
✓✓ Time and cost saving installation • Optimized valve and piping position for easy
maintenance
Reliable logistics • Refrigerant evacuation: function to enforce the
• Components delivered to job sites on time opening of outdoor units’ and indoor units’
✓✓ Enhanced installation efficiency expansion valves and solenoid valve’s bypass
✓✓ Proactive labor scheduling ✓✓ Easier and faster maintenance,
troubleshooting and repair
Online technical support
• All product information available on TS-Web: Comprehensive training
www.jci-hitachi.com/support/technical • Training modules tailored to specific job
functions
✓✓ All resources available 24/7 in one click
✓✓ Best practice installation
Super compact & light ✓✓ Ensures warranty compliance
• Outdoor units feature smaller cases and
compact footprints
• Best in class light weight
✓✓ Easier transportation & handling of
outdoor units
✓✓ Elevator friendly dimensions

H4-058_SMZ_HP_ODU_0614.indd 19 2019/06/14 14:46


For building
owners
You provide the spaces for our cooling
and heating systems. We design them

SET FREE Σ – FSNP & FSNS SERIES


to give you exceptional performance
and value.

System

Superior Performance Smooth Drive technology


•  Cooling EER up to 5.23 & Heating COP up to • Exclusive compressor control for VRF systems
6.19 (High Efficiency - FSNP series) • Continuous adjustment of compressor
•  Cooling EER up to 4.54 & Heating COP up to operation and refrigerant load according to
5.17 (Standard - FSNS series) indoor demand
✓✓ Smooth Drive ensuring your great ✓✓ Energy savings
performance in low-load operation ✓✓ Steady room temperature based on
set temperature in each zone
Rotational operation
• In combination units at partial load, modules Efficiency optimized for part-load operation
operate alternately so that operating hours are • Seasonal performance among industry’s
shared evenly highest for VRF systems
✓✓ Optimizes efficiency ✓✓ Saves energy all year long

WELCOME
✓✓ Extends service life
✓✓ Increases reliability Back-up Operation function
• Allows one outdoor unit module to be taken
Three step Night-quiet mode off-line for maintenance while remaining units
• Available function to limit the noise of outdoor keep operating
units (three step) ✓✓ No disruption during maintenance
✓✓ Ideal for locations with restrictions on
noise pollution

19 20

H4-058_SMZ_HP_ODU_0614.indd 20 2019/06/14 14:46


Compressor Outdoor Units

World leading Scroll Compressor technology New patented Σ shaped heat exchanger
•  Japanese precision engineering • Improved heat exchange rate
✓✓ Superior reliability and quality ✓✓ Contributes to superior efficiency

New compressor shield cover Demand control


• Cover reduces sound while maintaining power • Control and reduce power input within required
✓✓ Contributes to quieter outdoor unit operation range and time schedule
✓✓ Limits power consumption
DC Inverter Scroll Compressor ✓✓ Slows equipment wear and tear
• Optimum efficiency at regular load conditions ✓✓ Reduces noise
✓✓ Amongst the most energy efficient VRF
systems, with superior APF (annual Corrosion resistance
performance factor) • Available extra phosphoric acid chromate
treatment coating on the heat exchanger
Compressor modulation in 0.1Hz increments ✓✓ Ideal for locations with harsh outdoor
• Delivers the exact amount of refrigerant conditions (seaside)
required
✓✓ Extended equipment longevity and efficiency
✓✓ Enables fine control for optimum comfort
✓✓ Enhanced energy savings Innovative propeller fan
• Longer fan blades increase airflow quantity by
25%, resulting in higher static pressure
✓✓ Less energy required for equal output
✓✓ Extends motor life

Load shedding
• Turns units on/off and cycles between units at
10–20 minute intervals
✓✓ Enhanced energy savings
✓✓ Limits electric load demand

Low noise operation


• New compressor cover, fan and fan inlet
optimized for noise reduction
• Extremely low sound power level down to
67.5dB(A) (in low-noise setting mode)
✓✓ Less energy required for equal output
✓✓ Extends motor life

H4-058_SMZ_HP_ODU_0614.indd 21 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
Indoor Units Controls

Wide range of indoor units Fine control of indoor unit operation


• 14 types of indoor units available • 0.5/1.0°C increments of set temperature
• Colored panel option available • Adjustable fan speeds
✓✓ Greater design flexibility ✓✓ Precise control for greater comfort

Motion sensor option available H-LINK communication system


• Adjusts blown air temperature to the level • Centralized control of multiple indoor
of occupancy and outdoor units
• Stops air conditioning during extended • Versatility to connect various central
room vacancy control options
✓✓ Adaptive control based on room activity ✓✓ Indoor comfort tailored to building needs
levels ✓✓ Enhanced energy savings
✓✓ Cuts unnecessary operation and saves energy

WELCOME
✓✓ Improves system management

Variety of controllers
• Large range of individual and central
controllers, from simple to advanced functions
• Intuitive and user friendly
✓✓ Meets varied user requirements

BACnet® adapter for BMS integration


• Allows integration of SET FREE Σ into the
building management system, including
Metasys®
✓✓ Unified interface for all HVAC systems and
building functions

21 22

H4-058_SMZ_HP_ODU_0614.indd 22 2019/06/14 14:46


H4-058_SMZ_HP_ODU_0614.indd 23 2019/06/14 14:46

Outdoor units

SET FREE Σ – FSNP & FSNS SERIES


OUTDOOR UNITS
25 Outdoor unit overview

26 High efficiency

27 Better Perfomance

29 Design flexibility

33 Ease of maintenance

34 Reliability

39 Specifications

57 Optional parts

23 24

H4-058_SMZ_HP_ODU_0614.indd 24 2019/06/14 14:46



OUTDOOR UNIT OVERVIEW

SUMMARY TABLE

Item Unit High Efficiency - FSNP SERIES Standard - FSNS SERIES

Capacity HP class 5-72 8-96 

Nominal cooling capacity kW 14.0 - 201.0  22.4 - 268.0 

Nominal heating capacity kW 16.0 - 225.0  25.0 - 305.0 

Maximum connectable indoor unit quantity 64 64

Combination capacity ratio between ODU and IDU * % 50-150  50-130 

Total piping length m 1,000 1,000

Maximum piping length between ODU and IDU m 165 165

Maximum equivalent piping length between ODU and IDU m 190 190

Maximum piping length between 1st branch and IDU m 90 90

Maximum height difference between ODU and IDU **


m 110 110
(when ODU is higher than IDU)

Maximum height difference between ODU and IDU **


m 110 110
(when IDU is higher than ODU)

Maximum height difference between IDU and IDU m 30 30

Cooling operation range *** °C  DB -5.0 to 52.0 -5.0 to 48.0

Cooling operation range with low ambient setting *** °C  DB -10.0 to 52.0 **** -10.0 to 48.0 ****

Heating operation range *** °C WB -20.0 to 15.0 -20.0 to 15.0

* 50-150% (5-54HP class)/50-130% (56-72HP class)


** Please consult your distributor or dealer if the height different is over 50 metre. The maximum piping length for 56 to 72HP class (High Efficiency - FSNP series) & 72-96HP class (Standard - FSNS
series) is 90 metre.
*** For more details, please consult your distributors or dealer, or, refer to technical manuals
**** Available only 5-54HP class range

H4-058_SMZ_HP_ODU_0614.indd 25 2019/06/14 14:46



HIGH EFFICIENCY

SETTING THE NEW STANDARD FOUR KEY IMPROVEMENTS

SET FREE Σ – FSNP & FSNS SERIES


FOR GREATER EFFICIENCY
SET FREE Σ lifts performance and efficiency to a
new level. Choose High Efficiency - FSNP series or
Standard - FSNS series, offering a wider range of
operating ambient temperatures and increased
indoor unit combination capacity. Both will
reward you with superior performance as well as HEAT COMPRESSOR FAN COMPRESSOR
significant energy and cost savings. EXCHANGER CONTROL

EFFICIENCY RATIO
High Efficiency - FSNP Series

Cooling EER 6.00


5.23 5.15
4.94
5.00 4.75
4.33 4.26 4.26
3.95
4.00

3.00

2.00
5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class
14.0 16.0 22.4 28.0 33.5 40.0 45.0 50.0 kW

Heating COP 6.19


6.00 5.55
5.37
5.18

OUTDOOR UNITS
5.08
5.00
4.54
4.21 4.06
4.00

3.00

2.00
5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class
16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.0 kW

Standard - FSNS Series

Cooling EER 6.00

5.00
4.54
4.22 4.13
4.00 3.68
3.43 3.47
3.24 3.16 3.11
3.00

2.00
8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class
22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 kW

Heating COP 6.00


5.17 5.09
5.00
4.49

4.00 3.60 3.58 3.65 3.70


3.55
3.29
3.00

2.00
8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class
25.0 31.5 37.5 45.0 50.0 56.0 63.0 69.0 77.5 kW

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre

25 26

H4-058_SMZ_HP_ODU_0614.indd 26 2019/06/14 14:46



BETTER PERFORMANCE

3 POINTS IMPROVEMENT

1) COMPRESSOR
Greater capacity control
100%
100% 15Hz~100Hz 100%
100% 11Hz~110Hz
The highly improved performance
as well as greater energy saving is
85 Steps 990 Steps
(by 1Hz) (by 0.1Hz)

Inverter Compressor
Inverter Compressor
Inverter Compressor
Inverter Compressor
achieved by adopting newly developed

Control Capacity
Control Capacity
Control Capacity
Control Capacity
high efficiency DC inverter compressor,
with outstandingly precise control
technology of 0.1Hz increments DCDC DCDC
inverter frequency. Another feature Inverter
Inverter
Compressor
Compressor
Inverter
Inverter
Compressor
Compressor
is the dramatically extended working 20%
20% 10%
10%
range, enabled by expanding the Max.
Max. Min.
Min.
Max.
Max. Cooling
Cooling Load
Load Min.
Min.
Cooling
Cooling Load
Load
compressor’s operating frequency
band, both upwards and downwards. Current model* New model*
*Example at 12HP class(33.5kW)

2) HEAT EXCHANGER
• The heat exchange area has been increased by more than 10% (single module)
• Greater heat exchange efficiency
New shape New angle
Split left-right Improved angle
heat exchanger Σ shape! of the curve

Current model (single module) New single medium & Large cabinet Current model (single module) New single medium & Large cabinet

3) FAN POWER
• Improvement of airflow volume by 23% (single module)
• Energy consumption in the driving shaft has decreased by 20% on average
Expansion of air outlets Improvement in bell-mouth

Air outlets area


Twin-fan +40% Smoother
air flow
Narrower

Longer
Less short
circuit !!
1,211mm
Air volume area: 4,403cm2 1,210mm
Air volume area: 6,334cm2

Current model New model Current model New model

H4-058_SMZ_HP_ODU_0614.indd 27 2019/06/14 14:46


SMOOTH DRIVE: SUPERIOR REFRIGERENT CYCLE CONTROL

SET FREE Σ – FSNP & FSNS SERIES


“Smooth Drive” is designed to solves the issue that “Efficiency is much lower
in low load operation” which has been raised by specialists for long time, by
optimizing both compressor and fan operation in the smoothest way.
Exclusive to Hitachi VRF technology, this newly developed refrigerant cycle
control technology, Smooth Drive, helps you achieve new standards in
performance and efficiency with our new outdoor units.
How does it benefit you?
Efficiency Comfort Reliability
Power consumption is reduced More constant indoor Less burden on compressor
by -39% in the testing condition temperature achieved by better thanks to suppressing
at air conditioning load 33%. responsiveness thanks to direct continuous on/off at low load
compressor frequency control. operation, leading to less liquid-
back and less shock into the
scroll compressor.
Power Constant

temp (°C)
consumption indoor
-39% temperature

time (hr)

More Burden Less Burden


Long life

OUTDOOR UNITS
Actual example of the new compressor control

Current model New model

Room 30.0 Room 30.0


Temp Temp
(°C) (°C)
25.0 25.0
Unstable Temperature Constant Room Temperature
20.0 20.0

15.0 15.0

10.0 10.0
Energy Consumption Loss
5.0 5.0 Smoother operation
Power Power
(kW) (kW)
0 0
60 120 180 60 120 180
Time(mm) Time(mm)
Room Temperature(°C) Room Temperature(°C)
Power(kW) Power(kW)
due to frequent
switching on/off -39%
operation energy consumption

27 28

H4-058_SMZ_HP_ODU_0614.indd 28 2019/06/14 14:46



DESIGN FLEXIBILITY

EASIER HANDLING OUTDOOR UNITS

SET FREE Σ outdoor units are compact, lightweight and easily transportable; designed to make life easier for the
New Current New Current
people who specify, install and service them. Offering a wide choice of capacities with compact and flexible piping
options, each unit can be connected to up to 64 indoor units. 1,210mm 1,210mm
1,920mm 2,160mm

COMPACT
High Efficiency - FSNP series
Space Weight New

-14%
New Current

-15%
on average
Current
2,830mm on average
3,410mm

New
Current

14HP class 26HP class


4.0kW Space 73.0kW Space
New Current New Current
-44% New Current
-23%
1,210mm 1,210mm Weight 2,830mm Weight
1,920mm 2,160mm
-43% 3,630mm
-23%
Space:1.67m2 0.93m2 Space:2.81m2 2.16m2
Weight:475kg 270kg Weight:780kg 604kg

Standard - FSNS series


New Current New Current
Space Weight New

New Current
-11% Current 1,210mm
1,920mm
-16%
on average
1,210mm
2,160mm
on average
2,830mm
3,410mm
New
Current

18HP class 42HP class


50.0kW Space 118.0kW Space

New
New
Current
Current
-37% New Current New Current
-17%
1,210mm Weight
1,210mm 2,830mm Weight
2,830mm
3,630mm
1,920mm
-30% 2,160mm 3,410mm
-20%
Space:1.47m2 0.93m2 Space:2.61m2 2.16m2
Weight:445kg 311kg Weight:850kg 676kg

EASY TRANSPORTATION New Current

New Current
Smaller Lighter 2,830mm
Lift 3,630mm Crane
Can be transported in an elevator 2,830mm
800mm New package design to be craned
High Efficiency - FSNP series: 3,410mm more easily
14HP class(40.0kW)
Standard - FSNS series:
18HP class(50.0kW)

New Current

2,830mm 1,210mm
765mm
3,630mm

1,350mm

H4-058_SMZ_HP_ODU_0614.indd 29 2019/06/14 14:46


WB WB

15.0°C 15.0°C
0

0
OPERATION TEMPERATURE RANGE

SET FREE Σ – FSNP & FSNS SERIES


-20.0°C -20.0°C

Expansion of scope of outdoor operating temperature

High Efficiency - FSNP series Standard - FSNS series

DB DB WB DB DB WB

52.0°C 52.0°C
48.0°C 48.0°C

15.0°C 15.0°C
0

0
-5.0°C -5.0°C
-10.0°C -10.0°C

-20.0°C -20.0°C

Cooling Cooling with Heating Cooling Cooling with Heating


low ambient setting low ambient setting
(≤54HP class) DB (≤54HP class) DB

NOTES: 52.0°C
*Refer to the technical catalog for the detail. 48.0°C
** There are some conditions for “Low Ambient Setting”. Refer to the technical catalogue for the detail, and, consult your dealer in inquiry.
0

0
-5.0°C -5.0°C
IDU COMBINATIONS RANGE

OUTDOOR UNITS
Expansion of number of connectable indoor units Up to
130%
Standard - FSNS series

38HP class(106.0kW) 64 units at maximum

Outdoor Unit Capacity_HP class 5 6 8 10 12 14 16, 18 20 22 24 26 28 30 32 34 36 38-54 56-96

Range of Combination Capacity 50-150%: High Efficiency Type (FSNP series)(5-54HP class)
50-130%: High Efficiency Type (FSNP series)(56-72HP class) & Standard Type (FSNS series)

Connectable Indoor Units Q'ty 8 9 13 16 19 23 26 33 36 40 43 47 50 53 56 59 64 64

Recommended Connectable 5 5 8 10 10 16 16 18 20 26 26 32 32 32 32 32 38 38
Indoor Units Q'ty

NOTES:
1. T
 he connectable indoor unit capacity ratio can be calculated as follows. Connectable Indoor Unit Capacity Ratio=Total Indoor Unit Capacity/Total Outdoor Unit Capacity
2. F or the system under which all the indoor units are supposed to operate simultaneously, the total indoor unit capacity should be less than outdoor unit capacity. Otherwise, it may cause a
decrease of operating performance and operating limit in overload operation.
3. F or the system under which all the indoor units are not supposed to operate simultaneously, the total indoor unit capacity is available up to 130% (or 150%) against the outdoor unit capacity.
4. W
 hen operating the outdoor unit in cold areas with temperatures of -10.0°C, or under the high heating load conditions, the total indoor unit capacity should be less than 100% against the outdoor
unit capacity and the total piping length should be less than 300 metre.
5. T
 he air flow volume for indoor units of 0.8 and 1.0HP class is set higher than that for indoor units of 1.5HP class or more. Make sure to select appropriate indoor units when installing indoor units
where cold draft may occur during heating operation. If installing indoor units in such places, refer to the recommended number of connectable indoor units.
6. F or connecting Tempclean Indoor Unit and Outdoor Air Processing Air Conditioner, the number of the indoor units should be within recommended connectable indoor units number.
7. If combination capacity of indoor units exceed 100% of outdoor unit capacity, there might be the possibility of insufficient capacity of 130% (High Efficiency Type (FSNP series) (56-72HP class)/
Standard type (FSNS series)) and 150% (High Efficiency Type (FSNP series)(5-54HP class)) combination ratio. Refer to the technical catalog for the detail. If combination capacity exceed 130%(High
Efficiency - FSNP series: 56-72HP class & Standard - FSNS series) or 150%(High Efficiency - FSNP series: 5-54HP class) contact your distributer or dealer.

29 30

H4-058_SMZ_HP_ODU_0614.indd 30 2019/06/14 14:46


IMPROVED EXTERNAL STATIC PRESSURE

High static pressure for outdoor units: New Model 4 Options available
Wall
can handle up to 80Pa 0Pa 30Pa 60Pa 80Pa

Duct (Field Supplied)


Offers more options for the indoor installation of the outdoor unit
• Less piping length
• Lower installation cost
• Visual aesthetics

* Please refer to the


technical catalogue
for more details. Wall Outdoor Unit

PIPING CONNECTION WORKABILITY

Improvement of restrictions on piping construction

• Suitable for a high-rise building or complex facilities.


• Leads to cost/time saving for designers, with more efficient design.

Maximum Total sum 1,000m Maximum Between ODUs 0.1m


piping level
length Maximum length from ODU stope Actual 165m difference Between ODU and IDU ODU above IDU Standard: 50m
valve or Piping connection kit to Optional: 110m
Terminal IDU Equivalent 190m
IDU above ODU Standard: 40m
Between Piping Connection Kit and Each ODU 10m Optional: 110m

Between 1st branch Multi Kit and the farthest IDU 90m Between IDUs 30m

Between each Multi Kit and each IDU 40m

Notes:
1. Please consult your distributor if your required system is over the recommended connectable number of indoor units.
2. Maximum level difference between ODU and IDU (ODU above IDU) for 56-72HP class (High Efficiency - FSNP series) & 56-96HP class (Standard - FSNS series) is 90 metre.
Longer piping (up to 110 metre) is available for up to 54HP class only.
3. Your contact to distributor is required when maximum level different between ODU and IDU is over 50 metre (ODU above IDU) / 40 metre (IDU over ODU).

Example: Example:
∙ 26-36 HP class (FSNP series) Piping connection kit ∙ 56-72 HP class (FSNS series) Piping connection kit
∙ 26-48 HP class (FSNS series) MC-NP21SA1 MC-NP31SA

Branch pipe Branch pipe Branch pipe Branch pipe


for gas line for liquid line for gas line for liquid line

Multi kit

Gas side Liquid side


Up to 110m*

Up to 110m*
30m

30m

Multi kit

90m 90m
165m 165m
(Actual) Gas side Liquid side (Actual)

H4-058_SMZ_HP_ODU_0614.indd 31 2019/06/14 14:46


DEDICATED TO HIGH PERFORMANCE AND RELIABILITY

SET FREE Σ – FSNP & FSNS SERIES


SET FREE Σ
Air Source
Hitachi’s G1TOWER was completed in 2010. Heat Pump type
One of the world’s highest elevator research High Efficiency - FSNP series

towers, it’s the setting for tests on high-


performance, reliable elevators that fit the
needs of increasingly high-rise, large-scale
buildings inside and outside of Japan.
Wall mounted type
Indoor Unit
We also use this tower to test our actual
products in line with these trends to evaluate
their performance and reliability.

Supported by
110m
Name: G1TOWER
Address: 1070 Ichige, Hitachinaka-shi, Ibaraki Prefecture(in Mito Works)
Land area: 388m2
Building size: 213.5m above ground, 15m below ground
Floors: Nine above ground, one below ground
Owner: Building Systems Business Unit; Hitachi, Ltd.
http://www.hitachi.com/businesses/elevator/about_us/g1tower/

110m

SET FREE Σ
Air Source Heat Pump type
High Efficiency - FSNP series

31 32

H4-058_SMZ_HP_ODU_0614.indd 32 2019/06/14 14:46



EASE OF
MAINTENANCE

With a 7-segment display, revised upper


and lower panels and convenient access to
compressors and valves, SET FREE Σ outdoor
units are easier to access, manage and maintain.

New design features


• Easy maintenance via redesigned service access points
• Upper panel section provides high visibility and easy
replacement of PCBs
• Lower panel is independently removable, allowing access
to compressors and expansion valves for easy refrigerant
recovery

1 Upper section allows easy access to PCBs

2 New access window for 7-segment display

3 Independently detachable upper and lower panels

4 Lower section allows access to compressors and valves

5 New DSW setting for refrigerant evacuation

open

H4-058_SMZ_HP_ODU_0614.indd 33 2019/06/14 14:46



RELIABILITY

BUILT TO PERFORM

SET FREE Σ – FSNP & FSNS SERIES


You can count on SET FREE Σ to perform reliably in
the harshest of environments. The cabinet is built
on with a toughened, rigid frame designed to
withstand external shocks. Even in the unlikely event
of one unit in the module failing, the emergency
backup system ensures uninterrupted operation
by distributing the load to the modular units.

ROTATIONAL OPERATION SYSTEM FAILURE PREVENTION


• To improve unit endurance, standardized In case of a combination unit
running time evenly distributes the load by • The Backup Operation Function prevents the system from
rotating the order of compressor operation coming to a complete stop when module failure occurs
• If one module should fail, the system can continue to
operate using the remaining outdoor units
• An alarm is triggered and emergency operation can be
activated via an individual remote control
• Emergency operation can be performed within 8 hours
after unit stoppage
off on on • At least 2 modules (combined unit) are required for
this function

OUTDOOR UNITS
Rotation
on on off on off on

Combined outdoor unit

SOLID EXTERNAL PARTS OIL RETURN CONTROL


• Increased rigidity in the front and back of the frame As well as reducing lubricating oil loss, the patented oil
reduces the possibility of damage from external impacts return control cycle consumes less energy and produces
much less noise in the surrounding environment – resulting
in higher efficiency and greater comfort for occupants.

• Every hour, oil return operation activates for just 60


seconds (cooling mode)/120 seconds (heating mode)
• During oil return mode, indoor units can continue to
operate normally

Oil return circuit

Oil separator

More robust frame

Accumulator
Compressor
ANTI-CORROSION
Oil return port
• Optional anti-corrosion treatment improves reliability in
Pressure
coastal environments equalization port

33 34

H4-058_SMZ_HP_ODU_0614.indd 34 2019/06/14 14:46


SUPERIOR DEFROSTING PERFORMANCE

During heating mode, revolutionary defrosting technology ensures trouble free


operation and lower maintenance. Intelligent sensing detects when defrosting is
required and instantly adjusts the exterior case temperature to eliminate ice and frost.

• The lower part of heat exchanger uses sub-cooling refrigerant that prevents frost and ice formation to
provide continuous heating
• For the comfort of your building occupants, indoors unit fans are stopped during defrosting so that no
cold air is blown on those inside
• The maximum defrosting interval is now 250 minutes


Please refer to the Technical Catalog for more
information on defrosting technology.

image

frosting

cold

warm

No Frost!
hot

Current Model (image) New Model (image)

Unstable Temperature More constant Temperature

More efficient
Room
Temperature
Heating
Power

Heating Defrosting and


on
comfortable

Heating duration
more than 200%
longer
Time Time

on off on off on

No cold air flow to Indoor


thanks to automatic IDU stop

H4-058_SMZ_HP_ODU_0614.indd 35 2019/06/14 14:46



RESISTANCE TO SALT DAMAGE SPECIFICATIONS
PRODUCTS FOR ORDER

ABOUT THE INSTALLATION LOCATION

SET FREE Σ – FSNP & FSNS SERIES


Resistance to salt damage specifications Resistance to heavy salt damage specifications

A location that is not exposed to sea A place that is susceptible to sea breezes
breezes, but that appears to be suitable (But the device is not directly exposed to
ODU ODU
Installation

for such an atmosphere water containing salt.)


Location

ODU ODU

sea sea sea sea

∙ A location where the outdoor unit receives little rain


∙ A location where the outdoor unit is rinsed by the rain
installation location

∙ A location that is directly exposed to sea breezes


Requirements for

∙ A location that is not exposed to sea breezes


∙ A location where the distance from the installation location of the outdoor unit to the sea is
∙ A location where the distance from the installation location of the outdoor unit to the sea is
up to approximately 300 meters
between approximately 300 meters and one kilometer
∙ A location where the outdoor unit is mounted on the front of a building (beach side)
∙ A location where the outdoor unit is in the shelter of a building
∙ A location where corrugated iron roofs and the steel parts of balconies near the installation
location of the outdoor unit are often repainted

THE STANDARD OF THE INSTALLATION DISTANCE FROM THE BEACH


(conditions vary according to the installation environment)

1 A LOCATION THAT RECEIVES DIRECT SEA BREEZES


The standard of the installation distance
(1) A region that faces an inland sea 300 m 500 m 1,000 m
(2) A region that faces the open sea

OUTDOOR UNITS
(3) Okinawa and remote islands
Resistance to salt damage Resistance to heavy salt damage

2 A LOCATION THAT DOES NOT RECEIVE DIRECT SEA BREEZES


The standard of the installation distance
(1) A region that faces an inland sea 300 m 500 m 1,000 m
(2) A region that faces the open sea
(3) Okinawa and remote islands
Resistance to salt damage Resistance to heavy salt damage

POINTS TO NOTE FOR INSTALLATION, MAINTENANCE AND MANAGEMENT


Points to note for installation (regarding maintenance and management)
The units of JRA specifications for resistance to salt damage and resistance to heavy salt damage are made with strengthened materials and paints, but they are not fully protected
against corrosion.
It is therefore necessary to increase the anti-corrosion effects by carrying out the following installation plans and maintenance work.

(1) Please install the device in a location that avoids direct sea water splashes and sea breezes as much as possible.
∙Please install the device on the leeward side of a building.
∙If you have to install a device on the side of the beach, please avoid exposing it to direct sea breezes by erecting a wind-protective board.
∙Please be careful about the direction of installation. (The degree of corrosion differs depending on whether a device is installed parallel to the coastline or perpendicular
to the coastline.)
(2) Please ensure that any sea salt particles that adhere to the exterior panels will be washed away by the rain.
(3) Because the pooling of water on the bottom base of the outdoor unit significantly boosts the corrosion effects, please be careful about the inclination so that the ability
for water to run through the bottom base of an outdoor unit will not be affected.
(4) For a device installed in a beach area, please rinse it with water on a regular basis to remove all salt adhering to the device.
(5) Please install the device in a location where water drains away well. In particular, please secure the drainage of the foundation parts.
(6) Please be sure to repair any scratches that are created during the installation and maintenance work.
(7) Please inspect the conditions of the device on a regular basis. (If necessary, please apply anti-rust treatments or replace parts.)

Points to note for maintenance


∙Please carry out sufficient maintenance work on the device.
∙If you stop using the device for a long time, such as during the off-season, please take measures such as putting a cover on the device.

*If you install the device in a special atmosphere, you will need to undertake sufficient special consideration.
Units that are resistant to salt damage are based on the “Standard of Testing Resistance to Salt Damage of Air Conditioning Devices JRA9002” of the Japan Refrigeration and Air
Conditioning Industry Association (JRAIA).

35 36

H4-058_SMZ_HP_ODU_0614.indd 36 2019/06/14 14:46


“If we are advertising
that the heating
function works in an
environment down
to -20°C, we will test
up to -24°C.”
Mr Tomokazu Inaba,
Quality Assurance

H4-058_SMZ_HP_ODU_0614.indd 37 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
OUTDOOR UNITS

37 38

H4-058_SMZ_HP_ODU_0614.indd 38 2019/06/14 14:46



SPECIFICATIONS (High Efficiency - FSNP series)

HP Class 5 6 8 10 12 14

Model RAS-5FSNP RAS-6FSNP RAS-8FSNP RAS-10FSNP RAS-12FSNP RAS-14FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 14.0 16.0 22.4 28.0 33.5 40.0

Nominal Heating Capacity kW 16.0 18.0 25.0 31.5 37.5 45.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×950×765 1,675×950×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765

Sound Level Sound Power Level dB(A) 75 78 77 82 83 85

Sound Pressure Level dB(A) 54 56 55 59 60 62

Weight Net Weight 400V/50Hz kg 190 190 255 259 260 270
380-415V/50Hz
380V/60Hz

220V/60Hz kg 185 185 250 254 255 265

Gross Weight 400V/50Hz kg 206 206 273 277 278 288


380-415V/50Hz
380V/60Hz

220V/60Hz kg 201 201 268 272 273 283

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 4.7 5.0 8.5 8.5 9.3 9.3

Compressor Type Hermetic (Scroll)

Model AA50PHD AA50PHD AA50PHD DB65PHD DC80PHD DC80PHD

Quantity 1 1 1 1 1 1

Motor Output (Pole) kW 1.9(6) 2.1(6) 3.1(6) 3.8(6) 5.1(6) 6.4(6)

Refrigeration Oil Type FVC68D

Charge L/Unit 6.0 6.0 6.0 6.0 6.0 6.9

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 1 1 2 2 2 2

Air Flow Rate m3/min. 150 170 185 219 219 243

Motor Output (Pole) kW 0.20(8) 0.28(8) 0.18(8)×2 0.26(8)×2 0.26(8)×2 0.34(8)×2

Main Refrigerant Liquid Line mm φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 φ12.7
Piping

Heat Pump Gas Line mm φ15.88 φ19.05 φ19.05 φ22.2 φ25.4 φ25.4
System (2 Pipes)

Package Dimensions H×W×D mm 1,800×1,030×810 1,800×1,030×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810

Measurement m3 1 .5 1.5 1.9 1.9 1.9 1.9

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

H4-058_SMZ_HP_ODU_0614.indd 39 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
HP Class 16 18 20 22 24

Model RAS-16FSNP RAS-18FSNP RAS-20FSNP RAS-22FSNP RAS-24FSNP

Combination of Base Unit – – RAS-10FSNP RAS-10FSNP RAS-12FSNP


RAS-10FSNP RAS-12FSNP RAS-12FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 45.0 50.0 56.0 61.5 67.0

Nominal Heating Capacity kW 50.0 56.0 63.0 69.0 77.5

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×1,600×765 1,675×1,600×765 1,675×2,440×765 1,675×2,440×765 1,675×2,440×765

Sound Level Sound Power Level dB(A) 85 86 85 86 86

Sound Pressure Level dB(A) 65 65 62 62.5 63

Weight Net Weight 400V/50Hz kg 345 360 259+259 259+260 260+260


380-415V/50Hz
380V/60Hz

220V/60Hz kg 340 355 254+254 254+255 255+255

Gross Weight 400V/50Hz kg 365 380 277+277 277+278 278+278


380-415V/50Hz
380V/60Hz

220V/60Hz kg 360 375 272+272 272+273 273+273

Refrigerant Type R410A

OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 10.0 10.6 17.0 17.8 18.6

Compressor Type Hermetic (Scroll)

Model AA50PHD+AA50PHD DC80PHD+DC80PHD DB65PHD+DB65PHD DB65PHD+DC80PHD DC80PHD+DC80PHD

Quantity 2 2 2 2 2

Motor Output (Pole) kW 3.7(6)×2 4.4(6)×2 3.8(6)×2 3.8(6)×1+5.1(6)×1 5.1(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 7.9 7.9 12 12 12

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 2 2 4 4 4

Air Flow Rate m3/min. 326 362 219 × 2 219 × 2 219 × 2

Motor Output (Pole) kW 0.47(8)×2 0.62(8)×2 0.26(8)×2+0.26(8)×2 0.26(8)×2+0.26(8)×2 0.26(8)×2+0.26(8)×2

Main Refrigerant Liquid Line mm φ12.7 φ15.88 φ15.88 φ15.88 φ15.88


Piping

Heat Pump Gas Line mm φ28.58 φ28.58 φ28.58 φ28.58 φ28.58


System (2 Pipes)

Package Dimensions H×W×D mm 1,800×1,680×810 1,800×1,680×810 – – –

Measurement m3 2.4  2.4  – – –

Notes:
1. T
 he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre (RAS-16~18FSNP) Piping Length: 7.5 metre (RAS-16~18FSNP)
10.0 metre (RAS-20~24FSNP) 10.0 metre (RAS-20~24FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
 xcept for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. T
 he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

39 40

H4-058_SMZ_HP_ODU_0614.indd 40 2019/06/14 14:46



SPECIFICATIONS (High Efficiency - FSNP series)

HP Class 26 28 30 32 34 36

Model RAS-26FSNP RAS-28FSNP RAS-30FSNP RAS-32FSNP RAS-34FSNP RAS-36FSNP

Combination of Base Unit RAS-10FSNP RAS-12FSNP RAS-12FSNP RAS-14FSNP RAS-16FSNP RAS-18FSNP


RAS-16FSNP RAS-16FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 73.0 77.5 85.0 90.0 95.0 100.0

Nominal Heating Capacity kW 82.5 90.0 95.0 100.0 106.0 112.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765 1,675×3,220×765 1,675×3,220×765

Sound Level Sound Power Level dB(A) 87 87 88 89 89 89

Sound Pressure Level dB(A) 66 66 66 67 68 68

Weight Net Weight 400V/50Hz kg 259+345 260+345 260+360 270+360 345+360 360+380
380-415V/50Hz
380V/60Hz

220V/60Hz kg 254+340 255+340 255+355 265+355 340+355 355+355

Gross Weight 400V/50Hz kg 277+365 278+365 278+380 288+380 365+380 380+380


380-415V/50Hz
380V/60Hz

220V/60Hz kg 272+360 273+360 273+375 283+375 360+375 375+375

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 18.5 19.3 19.9 19.9 20.6 21.2

Compressor Type Hermetic (Scroll)

Model DB65PHD DC80PHD DC80PHD DC80PHD AA50PHD DC80PHD


+AA50PHD +AA50PHD +DC80PHD +DC80PHD +AA50PHD +DC80PHD
+AA50PHD +AA50PHD +DC80PHD +DC80PHD +DC80PHD +DC80PHD
+DC80PHD +DC80PHD

Quantity 3 3 3 3 4 4

Motor Output (Pole) kW 3.8(6)×1+3.7(6)×2 5.1(6)×1+3.7(6)×2 5.1(6)×1+4.4(6)×2 6.4(6)×1+4.4(6)×2 3.7(6)×2+4.4(6)×2 4.4(6)×2+4.4(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 13.9 13.9 13.9 14.8 15.8 15.8

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 4 4 4 4 4 4

Air Flow Rate m3/min. 219+326 219+326 219+362 243+362 326+362 362×2

Motor Output (Pole) kW 0.26(8)×2 0.26(8)×2 0.26(8)×2 0.34(8)×2 0.47(2)×2 0.62(8)×2


+0.47(8)×2 +0.47(8)×2 +0.62(8)×2 +0.62(2)×2 +0.62(2)×2 +0.62(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping

Heat Pump Gas Line mm φ31.75 φ31.75 φ31.75 φ31.75 φ31.75 φ38.1
System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre (RAS-26~30FSNP) Piping Length: 10.0 metre (RAS-26~30FSNP)
12.5 metre (RAS-32~36FSNP) 12.5 metre (RAS-32~36FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 41 2019/06/14 14:46


SET FREE Σ – FSNP & FSNS SERIES
HP Class 38 40 42 44 46

Model RAS-38FSNP RAS-40FSNP RAS-42FSNP RAS-44FSNP RAS-46FSNP

Combination of Base Unit RAS-12FSNP RAS-12FSNP RAS-14FSNP RAS-12FSNP RAS-14FSNP


RAS-12FSNP RAS-14FSNP RAS-14FSNP RAS-14FSNP RAS-14FSNP
RAS-14FSNP RAS-14FSNP RAS-14FSNP RAS-18FSNP RAS-18FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 106.0 112.0 118.0 122.0 128.0

Nominal Heating Capacity kW 118.0 125.0 132.0 140.0 145.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×3,670×765 1,675×3,670×765 1,675×3,670×765 1,675×4,060×765 1,675×4,060×765

Sound Level Sound Power Level dB(A) 89 89 90 90 90

Sound Pressure Level dB(A) 65.5 66 67 67.5 68

Weight Net Weight 400V/50Hz kg 260+260+270 260+270+270 270+270+270 260+270+360 270+270+360


380-415V/50Hz
380V/60Hz

220V/60Hz kg 255+255+265 255+265+265 265+265+265 255+265+355 265+265+355

Gross Weight 400V/50Hz kg 278+278+288 278+288+288 288+288+288 278+288+380 288+288+380


380-415V/50Hz
380V/60Hz

220V/60Hz kg 273+273+283 273+283+283 283+283+283 273+283+375 283+283+375

OUTDOOR UNITS
Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 27.9 27.9 27.9 29.2 30.5

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD DC80PHD+DC80PHD DC80PHD+DC80PHD DC80PHD+DC80PHD DC80PHD+DC80PHD


+DC80PHD +DC80PHD +DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 3 3 3 4 4

Motor Output (Pole) kW 5.1(6)×2+6.4(6)×1 5.1(6)×1+6.4(6)×2 6.4(6)×3 5.1(6)×1+6.4(6)×1 6.4(6)×1+6.4(6)×1


+4.4(6)×2 +4.4(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 18.9 19.8 20.7 20.8 21.7

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 6 6 6 6 6

Air Flow Rate m3/min. 219×2+243 219+243×2 243×3 219+243+362 243×2+362

Motor Output (Pole) kW 0.26(8)×2+0.26(8)×2 0.26(8)×2+0.34(8)×2 0.34(8)×2+0.34(8)×2 0.26(8)×2+0.34(8)×2 0.34(8)×2+0.34(8)×2


+0.34(8)×2 +0.34(8)×2 +0.34(8)×2 +0.62(8)×2 +0.62(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05


Piping

Heat Pump Gas Line mm φ38.1 φ38.1 φ38.1 φ38.1 φ38.1


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 12.5 metre (RAS-38~44FSNP) Piping Length: 12.5 metre (RAS-38~44FSNP)
15.0 metre (RAS-46FSNP) 15.0 metre (RAS-46FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

41 42

H4-058_SMZ_HP_ODU_0614.indd 42 2019/06/14 14:46



SPECIFICATIONS (High Efficiency - FSNP series)

HP Class 48 50 52 54

Model RAS-48FSNP RAS-50FSNP RAS-52FSNP RAS-54FSNP

Combination of Base Unit RAS-12FSNP RAS-14FSNP RAS-16FSNP RAS-18FSNP


RAS-18FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP
RAS-18FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 136.0 140.0 145.0 150.0

Nominal Heating Capacity kW 150.0 155.0 160.0 165.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×4,450×765 1,675×4,450×765 1,675×4,840×765 1,675×4,840×765

Sound Level Sound Power Level dB(A) 90 90 90 91

Sound Pressure Level dB(A) 68.5 69 70 70

Weight Net Weight 400V/50Hz kg 260+360+360 270+360+360 345+360+360 360+360+360


380-415V/50Hz
380V/60Hz

220V/60Hz kg 255+355+355 265+355+355 340+355+355 355+355+355

Gross Weight 400V/50Hz kg 278+380+380 288+380+380 365+380+380 380+380+380


380-415V/50Hz
380V/60Hz

220V/60Hz kg 273+375+375 283+375+375 360+375+375 375+375+375

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 30.5 30.5 31.2 31.8

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD DC80PHD+DC80PHD AA50PHD+AA50PHD DC80PHD+DC80PHD


+DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+DC80PHD  +DC80PHD  +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 5 5 6 6

Motor Output (Pole) kW 5.1(6)×1+4.4(6)×2+4.4(6)× 2 6.4(6)×1+4.4(6)×2+4.4(6)× 2 3.7(6)×2+4.4(6)×2+4.4(6)×2 4.4(6)×2+4.4(6)×2+4.4(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 21.8 22.7 23.7 23.7

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 6 6 6 6

Air Flow Rate m3/min. 219+362×2 243+362×2 326+362×2 362×3

Motor Output (Pole) kW 0.26(8)×2+0.62(8)×2 0.34(8)×2+0.62(8)×2 0.47(8)×2+0.62(8)×2 0.62(8)×2+0.62(8)×2


+0.62(8)×2 +0.62(8)×2 +0.62(8)×2 +0.62(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05


Piping

Heat Pump Gas Line mm φ38.1 φ38.1 φ38.1 φ38.1


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre Piping Length: 15.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 43 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 56 58

Model RAS-56FSNP RAS-58FSNP

Combination of Base Unit RAS-12FSNP RAS-12FSNP


RAS-12FSNP RAS-14FSNP
RAS-14FSNP RAS-14FSNP
RAS-18FSNP RAS-18FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 157.0 162.0

Nominal Heating Capacity kW 176.0 181.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×5,290×765 1,675×5,290×765

Sound Level Sound Power Level dB(A) 90 91

Sound Pressure Level dB(A) 68.5 68.5

Weight Net Weight 400V/50Hz kg 260+260+270+360 260+270+270+360


380-415V/50Hz
380V/60Hz

220V/60Hz kg 255+255+265+355 255+265+265+355

Gross Weight 400V/50Hz kg 278+278+288+380 278+288+288+380


380-415V/50Hz
380V/60Hz

220V/60Hz kg 273+273+283+375 273+283+283+375

OUTDOOR UNITS
Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 38.5 38.5

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD+DC80PHD+DC80PHD+DC80PHD DC80PHD+DC80PHD+DC80PHD+DC80PHD+DC80PHD

Quantity 5 5

Motor Output (Pole) kW 5.1(6)×2+6.4(6)+4.4(6)×2 5.1(6)+6.4(6)×2+4.4(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 26.8 27.7

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 8 8

Air Flow Rate m3/min. 219 × 2+243+362 219+243×2+362

Motor Output (Pole) kW (0.26(8)×2)×2+0.34(8)×2+0.62(8)×2 0.26(8)×2+(0.34(8)×2)×2+0.62(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05


Piping

Heat Pump Gas Line mm φ44.45 φ44.45


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre (RAS-56FSNP) Piping Length: 15.0 metre (RAS-56FSNP)
17.5 metre (RAS-58FSNP) 17.5 metre (RAS-58FSNP)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

43 44

H4-058_SMZ_HP_ODU_0614.indd 44 2019/06/14 14:47



SPECIFICATIONS (High Efficiency - FSNP series)

HP Class 60 62

Model RAS-60FSNP RAS-62FSNP

Combination of Base Unit RAS-14FSNP RAS-14FSNP


RAS-14FSNP RAS-16FSNP
RAS-16FSNP RAS-16FSNP
RAS-16FSNP RAS-16FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 167.0 174.0

Nominal Heating Capacity kW 188.0 196.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×5,680×765 1,675×6,070×765

Sound Level Sound Power Level dB(A) 91 91

Sound Pressure Level dB(A) 70 70.5

Weight Net Weight 400V/50Hz kg 270+270+345+345 270+345+345+345


380-415V/50Hz
380V/60Hz

220V/60Hz kg 265+265+340+340 265+340+340+340

Gross Weight 400V/50Hz kg 288+288+365+365 288+365+365+365


380-415V/50Hz
380V/60Hz

220V/60Hz kg 283+283+360+360 283+360+360+360

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 38.6 39.3

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD+AA50PHD+AA50PHD DC80PHD+AA50PHD+AA50PHD+AA50PHD


+AA50PHD+AA50PHD +AA50PHD+AA50PHD+AA50PHD

Quantity 6 7

Motor Output (Pole) kW 6.4(6)×2+(3.7(6)×2)×2 6.4(6)+(3.7(6)×2)×3

Refrigeration Oil Type FVC68D

Charge L/Unit 29.6 30.6

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 8 8

Air Flow Rate m3/min. 243×2+326×2 243+326×3

Motor Output (Pole) kW (0.34(8)×2)×2+(0.47(8)×2)×2 0.34(8)×2+(0.47(8)×2)×3

Main Refrigerant Liquid Line mm φ19.05 φ19.05


Piping

Heat Pump Gas Line mm φ44.45 φ44.45


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre Piping Length: 17.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 45 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 64 66 68 70 72

Model RAS-64FSNP RAS-66FSNP RAS-68FSNP RAS-70FSNP RAS-72FSNP

Combination of Base Unit RAS-16FSNP RAS-16FSNP RAS-16FSNP RAS-16FSNP RAS-18FSNP


RAS-16FSNP RAS-16FSNP RAS-16FSNP RAS-18FSNP RAS-18FSNP
RAS-16FSNP RAS-16FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP
RAS-16FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP RAS-18FSNP

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 179.0 184.0 190.0 196.0 201.0

Nominal Heating Capacity kW 202.0 207.0 213.0 220.0 225.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×6,460×765 1,675×6,460×765 1,675×6,460×765 1,675×6,460×765 1,675×6,460×765

Sound Level Sound Power Level dB(A) 91 91 92 91 92

Sound Pressure Level dB(A) 71 71 71 71 71

Weight Net Weight 400V/50Hz kg 345+345+345+345 345+345+345+360 345+345+360+360 345+360+360+360 360+360+360+360


380-415V/50Hz
380V/60Hz

220V/60Hz kg 340+340+340+340 340+340+340+355 340+340+355+355 340+355+355+355 355+355+355+355

Gross Weight 400V/50Hz kg 365+365+365+365 365+365+365+380 365+365+380+380 365+380+380+380 380+380+380+380


380-415V/50Hz
380V/60Hz

220V/60Hz kg 360+360+360+360 360+360+360+375 360+360+375+375 360+375+375+375 375+375+375+375

OUTDOOR UNITS
Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 40.0 40.6 41.2 41.8 42.4

Compressor Type Hermetic (Scroll)

Model AA50PHD+AA50PHD AA50PHD+AA50PHD AA50PHD+AA50PHD AA50PHD+AA50PHD DC80PHD+DC80PHD


+AA50PHD+AA50PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+AA50PHD+AA50PHD +AA50PHD+AA50PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+AA50PHD+AA50PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 8 8 8 8 8

Motor Output (Pole) kW (3.7(6)×2)×4 (3.7(6)×2)×3+4.4(6)×2 (3.7(6)×2)×2+(4.4(6)×2)×2 3.7(6)×2+(4.4(6)×2)×3 (4.4(6)×2)×4

Refrigeration Oil Type FVC68D

Charge L/Unit 31.6 31.6 31.6 31.6 31.6

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 8 8 8 8 8

Air Flow Rate m3/min. 326×4 326×3+362 326×2+362×2 326+362×3 362×4

Motor Output (Pole) kW (0.47(8)×2)×4 (0.47(8)×2)×3+0.62(8)×2 (0.47(8)×2)×2 0.47(8)×2+(0.62(8)×2)×3 (0.62(8)×2)×4


+(0.62(8)×2)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ22.2 φ22.2 φ22.2


Piping

Heat Pump Gas Line mm φ44.45 φ44.45 φ44.45 φ44.45 φ44.45


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre Piping Length: 17.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (20~72HP class 56.0~201.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

45 46

H4-058_SMZ_HP_ODU_0614.indd 46 2019/06/14 14:47



SPECIFICATIONS (Standard - FSNS series)

HP Class 8 10 12 14 16 18

Model RAS-8FSNS RAS-10FSNS RAS-12FSNS RAS-14FSNS RAS-16FSNS RAS-18FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 22.4 28.0 33.5 40.0 45.0 50.0

Nominal Heating Capacity kW 25.0 31.5 37.5 45.0 50.0 56.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×950×765 1,675×950×765 1,675×950×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765

Sound Level Sound Power Level dB(A) 80 82 82 85 85 86

Sound Pressure Level dB(A) 58 60 59 63 63 65

Weight Net Weight 400V/50Hz kg 190 190 210 268 310 311
380-415V/50Hz
380V/60Hz

220V/60Hz kg 185 185 205 263 305 306

Gross Weight 400V/50Hz kg 206 206 226 286 328 329


380-415V/50Hz
380V/60Hz

220V/60Hz kg 201 201 221 281 323 324

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 5.0 5.0 7.2 8.9 9.9 10.7

Compressor Type Hermetic (Scroll)

Model AA50PHD AA50PHD DC80PHD DC80PHD AA50PHD+AA50PHD AA50PHD+AA50PHD

Quantity 1 1 1 1 2 2

Motor Output (Pole) kW 3.3(6) 4.3(6) 5.4(6) 8.0(6) 4.5(6)×2 5.0(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 6.0 6.0 6.0 6.9 7.9 7.9

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 1 1 1 2 2 2

Air Flow Rate m3/min. 165 170 190 239 256 256

Motor Output (Pole) kW 0.26(8) 0.28(8) 0.42(8) 0.33(8)×2 0.39(8)×2 0.39(8)×2

Main Refrigerant Liquid Line mm φ9.52 φ9.52 φ12.7 φ12.7 φ12.7 φ15.88
Piping

Heat Pump Gas Line mm φ19.05 φ22.2 φ25.4 φ25.4 φ28.58 φ28.58
System (2 Pipes)

Package Dimensions H×W×D mm 1,800×1,030×810 1,800×1,030×810 1,800×1,030×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810

Measurement m3 1.5  1.5  1.5  1.9  1.9  1.9

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

H4-058_SMZ_HP_ODU_0614.indd 47 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 20 22 24

Model RAS-20FSNS RAS-22FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 56.0 61.5 67.0

Nominal Heating Capacity kW 63.0 69.0 77.5

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×1,600×765 1,675×1,600×765 1,675×1,600×765

Sound Level Sound Power Level dB(A) 86 84 86

Sound Pressure Level dB(A) 65 64 66

Weight Net Weight 400V/50Hz kg 350 364 365


380-415V/50Hz
380V/60Hz

220V/60Hz kg 345 359 360

Gross Weight 400V/50Hz kg 370 384 385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 365 379 380

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 11.3 11.3 11.6

OUTDOOR UNITS
Compressor Type Hermetic (Scroll)

Model AA50PHD+AA50PHD DC80PHD+DC80PHD DC80PHD+DC80PHD

Quantity 2 2 2

Motor Output (Pole) kW 5.5(6)×2 6.7(6)×2 7.1(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 8.4 8.4 8.4

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 2 2 2

Air Flow Rate m3/min. 329 329 348

Motor Output (Pole) kW 0.48(8)×2 0.48(8)×2 0.56(8)×2

Main Refrigerant Liquid Line mm φ15.88 φ15.88 φ15.88


Piping

Heat Pump Gas Line mm φ28.58 φ28.58 φ28.58


System (2 Pipes)

Package Dimensions H×W×D mm 1,800×1,680×810 1,800×1,680×810 1,800×1,680×810

Measurement m3 2.4  2.4  2.4 

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre Piping Length: 10.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

47 48

H4-058_SMZ_HP_ODU_0614.indd 48 2019/06/14 14:47



SPECIFICATIONS (Standard - FSNS series)

HP Class 26 28 30 32 34 36

Model RAS-26FSNS RAS-28FSNS RAS-30FSNS RAS-32FSNS RAS-34FSNS RAS-36FSNS

Combination of Base Unit RAS-10FSNS RAS-12FSNS RAS-12FSNS RAS-14FSNS RAS-16FSNS RAS-18FSNS


RAS-16FSNS RAS-16FSNS RAS-18FSNS RAS-18FSNS RAS-18FSNS RAS-18FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 73.0 77.5 85.0 90.0 95.0 100.0

Nominal Heating Capacity kW 82.5 90.0 95.0 100.0 106.0 112.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×2,180×765 1,675×2,180×765 1,675×2,180×765 1,675×2,440×765 1,675×2,440×765 1,675×2,440×765

Sound Level Sound Power Level dB(A) 87 87 87 89 89 89

Sound Pressure Level dB(A) 64.5 64.5 66 67 67 68

Weight Net Weight 400V/50Hz kg 210+268 210+310 210+311 268+311 310+311 311+311
380-415V/50Hz
380V/60Hz

220V/60Hz kg 205+263 205+305 205+306 263+306 305+306 306+306

Gross Weight 400V/50Hz kg 226+286 226+328 226+329 286+329 328+329 329+329


380-415V/50Hz
380V/60Hz

220V/60Hz kg 221+281 221+323 221+324 281+324 323+324 324+324

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 16.1 17.1 17.9 19.6 20.6 21.4

Compressor Type Hermetic (Scroll)

Model DC80PHD DC80PHD DC80PHD DC80PHD AA50PHD AA50PHD


+DC80PHD +AA50PHD +AA50PHD +AA50PHD +AA50PHD +AA50PHD
+AA50PHD +AA50PHD +AA50PHD +AA50PHD +AA50PHD
+AA50PHD +AA50PHD

Quantity 2 3 3 3 4 4

Motor Output (Pole) kW 5.4(6)×1+8.0(6)×1 5.4(6)×1+4.5(6)×2 5.4(6)×1+5.0(6)×2 8.0(6)×1+5.0(6)×2 4.5(6)×2+5.0(6)×2 5.0(6)×2+5.0(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 12.9 13.9 13.9 14.8 15.8 15.8

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 3 3 3 4 4 4

Air Flow Rate m3/min. 190+239 190+256 190+256 239+256 256×2 256×2

Motor Output (Pole) kW 0.42(8)+0.33(8)×2 0.42(8)+0.39(8)×2 0.42(8)+0.39(8)×2 0.33(8)×2+0.39(8)×2 0.39(8)×2+0.39(8)×2 0.39(8)×2+0.39(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping

Heat Pump Gas Line mm φ31.75 φ31.75 φ31.75 φ31.75 φ31.75 φ38.1
System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 10.0 metre (RAS-26~30FSNS) Piping Length: 10.0 metre (RAS-26~30FSNS)
12.5 metre (RAS-32~36FSNS) 12.5 metre (RAS-32~36FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 49 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 38 40 42 44 46 48

Model RAS-38FSNS RAS-40FSNS RAS-42FSNS RAS-44FSNS RAS-46FSNS RAS-48FSNS

Combination of Base Unit RAS-14FSNS RAS-18FSNS RAS-18FSNS RAS-22FSNS RAS-22FSNS RAS-24FSNS


RAS-24FSNS RAS-22FSNS RAS-24FSNS RAS-22FSNS RAS-24FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 106.0 112.0 118.0 122.0 128.0 136.0

Nominal Heating Capacity kW 118.0 125.0 132.0 140.0 145.0 150.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765 1,675×3,220×765 1,675×3,220×765 1,675×3,220×765

Sound Level Sound Power Level dB(A) 89 88 89 87 88 89

Sound Pressure Level dB(A) 68 67.5 68.5 67 68 69

Weight Net Weight 400V/50Hz kg 268+365 311+364 311+365 364+364 364+365 365+365
380-415V/50Hz
380V/60Hz

220V/60Hz kg 263+360 306+359 306+360 359+359 359+360 360+360

Gross Weight 400V/50Hz kg 286+385 329+384 329+385 384+384 384+385 385+385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 281+380 324+379 324+380 379+379 379+380 380+380

Refrigerant Type R410A

OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 20.5 22.0 22.3 22.6 22.9 23.2

Compressor Type Hermetic (Scroll)

Model DC80PHD AA50PHD AA50PHD DC80PHD DC80PHD DC80PHD


+DC80PHD +AA50PHD +AA50PHD +DC80PHD +DC80PHD +DC80PHD
+DC80PHD +DC80PHD +DC80PHD +DC80PHD +DC80PHD +DC80PHD
+DC80PHD +DC80PHD +DC80PHD +DC80PHD +DC80PHD

Quantity 3 4 4 4 4 4

Motor Output (Pole) kW 8.0(6)×1+7.1(6)×2 5.0(6)×2+6.7(6)×2 5.0(6)×2+7.1(6)×2 6.7(6)×2+6.7(6)×2 6.7(6)×2+7.1(6)×2 7.1(6)×2+7.1(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 15.3 16.3 16.3 16.8 16.8 16.8

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 4 4 4 4 4 4

Air Flow Rate m3/min. 239+348 256+329 256+348 329×2 329+348 348×2

Motor Output (Pole) kW 0.33(8)×2+0.56(8)×2 0.39(8)×2+0.48(8)×2 0.39(8)×2+0.56(8)×2 0.48(8)×2+0.48(8)×2 0.48(8)×2+0.56(8)×2 0.56(8)×2+0.56(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping

Heat Pump Gas Line mm φ38.1 φ38.1 φ38.1 φ38.1 φ38.1 φ38.1
System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 12.5 metre (RAS-38~44FSNS) Piping Length: 12.5 metre (RAS-38~44FSNS)
15.0 metre (RAS-46~48FSNS) 15.0 metre (RAS-46~48FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

49 50

H4-058_SMZ_HP_ODU_0614.indd 50 2019/06/14 14:47



SPECIFICATIONS (Standard - FSNS series)

HP Class 50 52 54

Model RAS-50FSNS RAS-52FSNS RAS-54FSNS

Combination of Base Unit RAS-14FSNS RAS-16FSNS RAS-18FSNS


RAS-18FSNS RAS-18FSNS RAS-18FSNS
RAS-18FSNS RAS-18FSNS RAS-18FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 140.0 145.0 150.0

Nominal Heating Capacity kW 155.0 160.0 165.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×3,670×765 1,675×3,670×765 1,675×3,670×765

Sound Level Sound Power Level dB(A) 90 90 91

Sound Pressure Level dB(A) 69 69 70

Weight Net Weight 400V/50Hz kg 268+311+311 310+311+311 311+311+311


380-415V/50Hz
380V/60Hz

220V/60Hz kg 263+306+306 305+306+306 306+306+306

Gross Weight 400V/50Hz kg 286+329+329 328+329+329 329+329+329


380-415V/50Hz
380V/60Hz

220V/60Hz kg 281+324+324 323+324+324 324+324+324

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 30.3 31.3 32.1

Compressor Type Hermetic (Scroll)

Model DC80PHD+AA50PHD+AA50PHD AA50PHD+AA50PHD+AA50PHD AA50PHD+AA50PHD+AA50PHD


+AA50PHD+AA50PHD +AA50PHD+AA50PHD+AA50PHD +AA50PHD+AA50PHD+AA50PHD

Quantity 5 6 6

Motor Output (Pole) kW 8.0(6)×1+5.0(6)×2+5.0(6)×2 4.5(6)×2+5.0(6)×2+5.0(6)×2 5.0(6)×2+5.0(6)×2+5.0(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 22.7 23.7 23.7

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 6 6 6

Air Flow Rate m3/min. 239+256×2 256×3 256×3

Motor Output (Pole) kW 0.33(8)×2+0.39(8)×2+0.39(8)×2 0.39(8)×2+0.39(8)×2+0.39(8)×2 0.39(8)×2+0.39(8)×2+0.39(8)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05


Piping

Heat Pump Gas Line mm φ38.1 φ38.1 φ38.1


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre Piping Length: 15.0 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 51 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 56 58 60 62 64 66

Model RAS-56FSNS RAS-58FSNS RAS-60FSNS RAS-62FSNS RAS-64FSNS RAS-66FSNS

Combination of Base Unit RAS-14FSNS RAS-18FSNS RAS-18FSNS RAS-14FSNS RAS-18FSNS RAS-18FSNS


RAS-18FSNS RAS-18FSNS RAS-18FSNS RAS-24FSNS RAS-22FSNS RAS-24FSNS
RAS-24FSNS RAS-22FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 157.0 162.0 167.0 174.0 179.0 184.0

Nominal Heating Capacity kW 176.0 181.0 188.0 196.0 202.0 207.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×4,060×765 1,675×4,060×765 1,675×4,060×765 1,675×4,450×765 1,675×4,450×765 1,675×4,450×765

Sound Level Sound Power Level dB(A) 90 90 91 90 90 91

Sound Pressure Level dB(A) 69.5 69.5 70 70 70 70.5

Weight Net Weight 400V/50Hz kg 268+311+365 311+311+364 311+311+365 268+365+365 311+364+365 311+365+365
380-415V/50Hz
380V/60Hz

220V/60Hz kg 263+306+360 306+306+359 306+306+360 263+360+360 306+359+360 306+360+360

Gross Weight 400V/50Hz kg 286+329+385 329+329+384 329+329+385 286+385+385 329+384+385 329+385+385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 281+324+380 324+324+379 324+324+380 281+380+380 324+379+380 324+380+380

Refrigerant Type R410A

OUTDOOR UNITS
Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 31.2 32.7 33.0 32.1 33.6 33.9

Compressor Type Hermetic (Scroll)

Model DC80PHD+AA50PHD AA50PHD+AA50PHD AA50PHD+AA50PHD DC80PHD+DC80PHD AA50PHD+AA50PHD AA50PHD + AA50PHD


+AA50PHD+DC80PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD +DC80PHD+DC80PHD +DC80PHD +DC80PHD

Quantity 5 6 6 5 6 6

Motor Output (Pole) kW 8.0(6)+5.0(6)×2  (5.0(6)×2)×2  (5.0(6)×2)×2 8.0(6)+(7.1(6)×2)×2 5.0(6)×2+6.7(6)×2 5.0(6)×2


+7.1(6)×2 +6.7(6)×2 +7.1(6)×2 +7.1(6)×2 +(7.1(6)×2)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 23.2 24.2 24.2 23.7 24.7 24.7

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 6 6 6 6 6 6

Air Flow Rate m3/min. 239+256+348 256+256+329 256+256+348 239+348+348 256+329+348 256+348+348

Motor Output (Pole) kW 0.33(8)×2+0.39(8)×2 (0.39(8)×2)×2 (0.39(8)×2)×2 0.33(8)×2 0.39(8)×2+0.48(8)×2 0.39(8)×2


+0.56(8)×2 +0.48(8)×2 +0.56(8)×2 +(0.56(8)×2)×2 +0.56(8)×2 +(0.56(8)×2)×2

Main Refrigerant Liquid Line mm φ19.05 φ19.05 φ19.05 φ19.05 φ19.05 φ19.05
Piping

Heat Pump Gas Line mm φ44.45 φ44.45 φ44.45 φ44.45 φ44.45 φ44.45
System (2 Pipes)

Notes:
1. T
 he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 15.0 metre (RAS-56FSNS) Piping Length: 15.0 metre (RAS-56FSNS)
17.5 metre (RAS-58~66FSNS) 17.5 metre (RAS-58~66FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
 xcept for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. T
 he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

51 52

H4-058_SMZ_HP_ODU_0614.indd 52 2019/06/14 14:47



SPECIFICATIONS (Standard - FSNS series)

HP Class 68 70 72 74 76 78

Model RAS-68FSNS RAS-70FSNS RAS-72FSNS RAS-74FSNS RAS-76FSNS RAS-78FSNS

Combination of Base Unit RAS-22FSNS RAS-22FSNS RAS-24FSNS RAS-14FSNS RAS-18FSNS RAS-18FSNS


RAS-22FSNS RAS-24FSNS RAS-24FSNS RAS-18FSNS RAS-18FSNS RAS-18FSNS
RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-18FSNS RAS-18FSNS RAS-18FSNS
RAS-24FSNS RAS-22FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 190.0 196.0 201.0 207.0 212.0 217.0

Nominal Heating Capacity kW 213.0 220.0 225.0 232.0 237.0 244.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×4,840×765 1,675×4,840×765 1,675×4,840×765 1,675×5,290×765 1,675×5,290×765 1,675×5,290×765

Sound Level Sound Power Level dB(A) 90 90 91 92 92 92

Sound Pressure Level dB(A) 69.5 70 71 71 71 71.5

Weight Net Weight 400V/50Hz kg 364+364+365 364+365+365 365+365+365 268+311+311+365 311+311+311+364 311+311+311+365
380-415V/50Hz
380V/60Hz

220V/60Hz kg 359+359+360 359+360+360 360+360+360 263+306+306+360 306+306+306+359 306+306+306+360

Gross Weight 400V/50Hz kg 384+384+385 384+385+385 385+385+385 286+329+329+385 329+329+329+384 329+329+329+385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 379+379+380 379+380+380 380+380+380 281+324+324+380 324+324+324+379 324+324+324+380

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 34.2 34.5 34.8 41.9 43.4 43.7

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD DC80PHD+DC80PHD DC80PHD+DC80PHD DC80PHD+AA50PHD AA50PHD+AA50PHD AA50PHD+AA50PHD


+DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD
+DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +AA50PHD+DC80PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD
+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 6 6 6 7 8 8

Motor Output (Pole) kW (6.7(6)×2)×2 6.7(6)×2 (7.1(6)×2)×3 8.0(6)+(5.0(6)×2)×2 (5.0(6)×2)×3 (5.0(6)×2)×3


+7.1(6)×2 +(7.1(6)×2)×2 +7.1(6)×2 +6.7(6)×2 +7.1(6)×2

Refrigeration Oil Type FVC68D

Charge L/Unit 25.2 25.2 25.2 31.1 32.1 32.1

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 6 6 6 8 8 8

Air Flow Rate m3/min. 329+329+348 329+348×2 348×3 239+256×2+348 256×3+329 256×3+348

Motor Output (Pole) kW (0.48(8)×2)×2 0.48(8)×2 (0.56(8)×2)×3 0.33(8)×2+(0.39(8)×2)×2 (0.39(8)×2)×3 (0.39(8)×2)×3


+0.56(8)×2 +(0.56(8)×2)×2 +0.56(8)×2 +0.48(8)×2 +0.56(8)×2

Main Refrigerant Liquid Line mm φ22.2 φ22.2 φ22.2 φ22.2 φ22.2 φ22.2
Piping

Heat Pump Gas Line mm φ44.45 φ44.45 φ44.45 φ50.8 φ50.8 φ50.8
System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 17.5 metre (RAS-68~72FSNS) Piping Length: 17.5 metre (RAS-68~72FSNS)
20.0 metre (RAS-74~78FSNS) 20.0 metre (RAS-74~78FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 53 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
HP Class 80 82 84 86 88 90

Model RAS-80FSNS RAS-82FSNS RAS-84FSNS RAS-86FSNS RAS-88FSNS RAS-90FSNS

Combination of Base Unit RAS-14FSNS RAS-16FSNS RAS-18FSNS RAS-14FSNS RAS-16FSNS RAS-18FSNS


RAS-18FSNS RAS-18FSNS RAS-18FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS
RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS
RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 224.0 230.0 234.0 241.0 246.0 251.0

Nominal Heating Capacity kW 254.0 261.0 267.0 275.0 282.0 287.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×5,680×765 1,675×5,680×765 1,675×5,680×765 1,675×6,070×765 1,675×6,070×765 1,675×6,070×765

Sound Level Sound Power Level dB(A) 92 92 92 92 92 92

Sound Pressure Level dB(A) 71 71 71.5 71.5 71.5 72

Weight Net Weight 400V/50Hz kg 268+311+365+365 310+311+365+365 311+311+365+365 268+365+365+365 310+365+365+365 311+365+365+365
380-415V/50Hz
380V/60Hz

220V/60Hz kg 263+306+360+360 305+306+360+360 306+306+360+360 263+360+360+360 305+360+360+360 306+360+360+360

Gross Weight 400V/50Hz kg 286+329+385+385 328+329+385+385 329+329+385+385 286+385+385+385 328+385+385+385 329+385+385+385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 281+324+380+380 323+324+380+380 324+324+380+380 281+380+380+380 323+380+380+380 324+380+380+380

OUTDOOR UNITS
Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 42.8 43.8 44.6 43.7 44.7 45.5

Compressor Type Hermetic (Scroll)

Model DC80PHD+AA50PHD AA50PHD+AA50PHD AA50PHD+AA50PHD DC80PHD+DC80PHD AA50PHD+AA50PHD AA50PHD+AA50PHD


+AA50PHD+DC80PHD +AA50PHD+AA50PHD +AA50PHD+AA50PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD
+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 7 8 8 7 8 8

Motor Output (Pole) kW 8.0(6)+5.0(6)×2 4.5(6)×2+5.0(6)×2 (5.0(6)×2)×2 8.0(6) 4.5(6)×2 5.0(6)×2


+(7.1(6)×2)×2 +(7.1(6)×2)×2 +(7.1(6)×2)×2 +(7.1(6)×2)×3 +(7.1(6)×2)×3 +(7.1(6)×2)×3

Refrigeration Oil Type FVC68D

Charge L/Unit 31.6 32.6 32.6 32.1 33.1 33.1

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 8 8 8 8 8 8

Air Flow Rate m3/min. 239 + 256 + 348 × 2 256 + 256 + 348 × 2 256  × 2 + 348 × 2 239 + 348 × 3 256 + 348 × 3 256 + 348 × 3

Motor Output (Pole) kW 0.33(8)×2+0.39(8)×2 0.39(8)×2+0.39(8)×2 (0.39(8)×2)×2 0.33(8)×2 0.39(8)×2 0.39(8)×2


+(0.56(8)×2)×2 +(0.56(8)×2)×2 +(0.56(8)×2)×2 +(0.56(8)×2)×3 +(0.56(8)×2)×3 +(0.56(8)×2)×3

Main Refrigerant Liquid Line mm φ22.2 φ22.2 φ22.2 φ22.2 φ22.2 φ25.4
Piping

Heat Pump Gas Line mm φ50.8 φ50.8 φ50.8 φ50.8 φ50.8 φ50.8
System (2 Pipes)

Notes:
1. T
 he cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 20.0 metre (RAS-80~84FSNS) Piping Length: 20.0 metre (RAS-80~84FSNS)
22.5 metre (RAS-86~90FSNS) 22.5 metre (RAS-86~90FSNS)
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. E
 xcept for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. T
 he width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

53 54

H4-058_SMZ_HP_ODU_0614.indd 54 2019/06/14 14:47



SPECIFICATIONS (Standard - FSNS series)

HP Class 92 94 96

Model RAS-92FSNS RAS-94FSNS RAS-96FSNS

Combination of Base Unit RAS-22FSNS RAS-22FSNS RAS-24FSNS


RAS-22FSNS RAS-24FSNS RAS-24FSNS
RAS-24FSNS RAS-24FSNS RAS-24FSNS
RAS-24FSNS RAS-24FSNS RAS-24FSNS

Power Supply 3~/N, [400V/50Hz] [380-415V/50Hz] [380V/60Hz] [220V/60Hz]

Nominal Cooling Capacity kW 258.0 263.0 268.0

Nominal Heating Capacity kW 293.0 299.0 305.0

Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)

Outer Dimensions H×W×D mm 1,675×6,460×765 1,675×6,460×765 1,675×6,460×765

Sound Level Sound Power Level dB(A) 92 92 92

Sound Pressure Level dB(A) 72 71.5 72

Weight Net Weight 400V/50Hz kg 364+364+365+365 364+365+365+365 365+365+365+365


380-415V/50Hz
380V/60Hz

220V/60Hz kg 359+359+360+360 359+360+360+360 360+360+360+360

Gross Weight 400V/50Hz kg 384+384+385+385 384+385+385+385 385+385+385+385


380-415V/50Hz
380V/60Hz

220V/60Hz kg 379+379+380+380 379+380+380+380 380+380+380+380

Refrigerant Type R410A

Flow Control Micro-Computer Control Expansion Valve

Charge (before Shipment) kg 45.8 46.1 46.4

Compressor Type Hermetic (Scroll)

Model DC80PHD+DC80PHD+DC80PHD DC80PHD+DC80PHD+DC80PHD DC80PHD+DC80PHD+DC80PHD


+DC80PHD+DC80PHD+DC80PHD +DC80PHD+DC80PHD+DC80PHD +DC80PHD+DC80PHD+DC80PHD
+DC80PHD+DC80PHD +DC80PHD+DC80PHD +DC80PHD+DC80PHD

Quantity 8 8 8

Motor Output (Pole) kW (6.7(6)×2)×2+(7.1(6)×2)×2 6.7(6)×2+(7.1(6)×2)×3 (7.1(6)×2)×4

Refrigeration Oil Type FVC68D

Charge L/Unit 33.6 33.6 33.6

Heat Exchanger Multi-Pass Cross-Finned Tube

Condenser Fan Type Propeller Fan

Quantity 8 8 8

Air Flow Rate m3/min. 329×2+348×2 329+348×3 348×4

Motor Output (Pole) kW (0.48(8)×2)×2+(0.56(8)×2)×2 0.48(8)×2+(0.56(8)×2)×3 (0.56(8)×2)×4

Main Refrigerant Liquid Line mm φ25.4 φ25.4 φ25.4


Piping

Heat Pump Gas Line mm φ50.8 φ50.8 φ50.8


System (2 Pipes)

Notes:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 22.5 metre Piping Length: 22.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure is based on the following conditions.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~96HP class 73.0~268.0kW), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.

H4-058_SMZ_HP_ODU_0614.indd 55 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
OUTDOOR UNITS

55 56

H4-058_SMZ_HP_ODU_0614.indd 56 2019/06/14 14:47



OPTIONAL PARTS

PIPING CONNECTION KIT


Piping connection kit for the divergence between outdoor units Example: MC-NP21SA1

Model Applicable ODU Remarks

HP class Connectivity
Number
FSNP series FSNS series

MC-NP20SA1 20-24 - 2 for Gas: 1 Branch Pipe for Gas Line Branch Pipe for Liquid Line
for Liquid: 1
MC-NP21SA1 26-36 26-48 2

MC-NP30SA1 38-54 50-54 3 for Gas: 2


for Liquid: 2
Example: MC-NP31SA
MC-NP31SA - 56-72 3 for Gas: 2
for Liquid: 2

MC-NP40SA 56-72 74-96 4 for Gas: 3


for Liquid: 3

NOTE: Gas Side Liquid Side


The old model (MC-TTA1) is not available.

MULTI-KIT
Branching for indoor and outdoor connecting pipes Example: MW-NP282A3
Line branch
First branching pipes

Model ODU HP class

MW-NP282A3 5-10

MW-NP452A3 12-16
Gas Side Liquid Side
MW-NP692A3 18-24

MW-NP902A3 26-54

MW-NP2682A3 56-96

Pipe diameter after the first branch and multi-kit

Model Total IDU HP class Diameter (mm)

Gas Pipe Liquid Pipe


MW-NP282A3 <6  Φ15.88 Φ9.52

6- 8.99  Φ19.05 Φ9.52

9-11.99  Φ22.2 Φ9.52


MW-NP452A3 12-15.99  Φ25.4 Φ12.7

16-17.99  Φ28.58 Φ12.7


MW-NP692A3 18-25.99  Φ28.58 Φ15.88
MW-NP902A3 26-35.99  Φ31.75 Φ19.05

36-55.99  Φ38.1 Φ19.05


MW-NP2682A3 56-67.99  Φ44.45 Φ19.05

68-73.99  Φ44.45 Φ22.2

74-89.99  Φ50.8 Φ22.2

≥ 90  Φ50.8 Φ25.4

Header branch

Model Total IDU HP class No. of Header Branches


Example: MH-NP224A
MH-NP224A 5-8 4

MH-NP288A 5-10 8

Gas Side Liquid Side

H4-058_SMZ_HP_ODU_0614.indd 57 2019/06/14 14:47


DRAIN BOSS

SET FREE Σ – FSNP & FSNS SERIES


The drain boss is for the drain pipe connection in order to use the DBS-TP10A
bottom base of the outdoor unit as a drain pan.
Quantity

Model Applicable ODU HP class Q’ty

FSNP series FSNS series


DBS-TP10A 5-14 8-18 1

16-24 20-36 2

26-32 38, 40 3

34, 36 42-48 4
Drain Boss×2 Drain Cap×2
38-42 50-54 3 To close the drain hole

44, 46 56-60 4

48, 50 62-66 5

52, 54 68-72 6

56, 58 74-78 5

60 80-84 6

62 86-90 7

64-72 92-96 8

CABINET COVER
Air inlet grille Image Left Side

OUTDOOR UNITS
HP class (kW) Rear Right Left

FSNP series FSNS series

5-6(14.0-16.0) 8-12(22.4-33.5) PSN-TP20BA PSN-TP20R PSN-TP20L

8-14(22.4-40.0) 14-18(40.0-50.0) PSN-TP20BB PSN-TP20R×2 PSN-TP20R×2 Right Side Rear Side


16-18(45.0-50.0) 20-24(56.0-67.0)  PSN-TP20BC PSN-TP20R×2 PSN-TP20R×2

Image Left Side


Protection net

HP class (kW) Rear Right Left

FSNP series FSNS series

5-6(14.0-16.0) 8-12(22.4-33.5) PN-TP20BA PN-TP20R PN-TP20L


Right Side Rear Side
8-14(22.4-40.0) 14-18(40.0-50.0) PN-TP20BB PN-TP20R×2 PSN-TP20R×2

16-18(45.0-50.0) 20-24(56.0-67.0) PN-TP20BC PN-TP20R×2 PSN-TP20R×2

Snow protection hood Image (for Left Side Air Inlet)

HP class (kW) Upper Rear Right Left


(for Air Outlet)
FSNP series FSNS series Zinc Coated Steel
Outdoor Unit
5-6(14.0-16.0) 8-12(22.4-33.5) ASG-TP50FA ASG-TP50BA ASG-TP50R ASG-TP50L
(for Rear Side Air Inlet)
8-14(22.4-40.0) 14-18(40.0-50.0) ASG-TP50FB ASG-TP50BB ASG-TP50R×2 ASG-TP50R×2
(for Right Side Air Inlet)
16-18(45.0-50.0) 20-24(56.0-67.0) ASG-TP50FC ASG-TP50BC ASG-TP50R×2 ASG-TP50R×2

Stainless

5-6(14.0-16.0) 8-12(22.4-33.5) ASG-TP50FAS ASG-TP50BAS ASG-TP50RS ASG-TP50LS

8-14(22.4-40.0) 14-18(40.0-50.0) ASG-TP50FBS ASG-TP50BBS ASG-TP50RS×2 ASG-TP50RS×2

16-18(45.0-50.0) 20-24(56.0-67.0) ASG-TP50FS ASG-TP50BCS ASG-TP50RS×2 ASG-TP50RS×2

Toppling prevention tool Image

HP class (kW) Φ2 Wire


FSNP series FSNS series Fastening Fitting
Anchor Bolt
5-18(14.0-50.0) 8-24(22.4-67.0) ASG-SW20A
(Field-Supplied)
Foundation

57 58

H4-058_SMZ_HP_ODU_0614.indd 58 2019/06/14 14:47


059-082_SMZ_HP_IDU_0614.indd 59 2019/06/14 14:50

Indoor units
& ventilation

SET FREE Σ – FSNP & FSNS SERIES


61 Line up overview

65 Cassette
65 4-way cassette type(RCI-FSN3)
66 4-way cassette compact type
67 2-way cassette type

INDOOR UNITS & VENTILATION


68 1-way cassette type

69 Ducted
70 High esp (external static pressure) type
71 Medium esp (external static pressure) type
72 Slim type
73 Compact type
(both AC motor type and DC motor type available)
74 Larger air volume type

75 Concealed & Exposed


75 Floor concealed type
76 Floor exposed type
77 Floor/Ceiling convertible type
78 Ceiling suspended type
79 Wall mounted type

81 Ventilation
81 Total heat exchanger
82 All fresh air unit

59 60

059-082_SMZ_HP_IDU_0614.indd 60 2019/06/14 14:50



LINE UP OVERVIEW
COMPARING INDOOR UNITS CAPACITY

Indoor Unit Category Cooling (kW) 1.6 1.7 2.2 2.3 2.8 2.9 3.6 3.8 4.0 4.4 5.0 5.6 6.3 7.1 8.0 8.4 9.0 11.2 14.0 14.2 16.0 18.0 22.4 28.0

CEILING 4-WAY CASSETTE TYPE • • • • • • • •


CASSETTE

4-WAY CASSETTE COMPACT • • • • • •


TYPE

2-WAY CASSETTE TYPE • • • • • • • • •

1-WAY CASSETTE TYPE • • • • • •

DUCTED HIGH ESP TYPE • • • • • • • •

MEDIUM ESP TYPE • • • • • • • • •

SLIM TYPE • • • •

COMPACT TYPE
(BOTH AC MOTOR TYPE AND
• • • • • • • •
DC MOTOR TYPE AVAILABLE)

LARGER AIR VOLUME TYPE • • • • •

CONCEALED FLOOR CONCEALED TYPE • • • •


AND
EXPOSED
FLOOR EXPOSED TYPE • • • •

FLOOR/CEILING • • • • • • • •
CONVERTIBLE TYPE

CEILING SUSPENDED TYPE • • • • • • •

WALL MOUNTED TYPE • • • • • • • •

COMPARING VENTILATIONS CAPACITY

Fan Air Flow Rate (m3/h) 200 300 400 500 650 800 1,000 1,080 1,250 1,500 1,680 2,000 2,100 2,500 3,000 4,000 5,000 6,000

TOTAL HEAT EXCHANGER • • • • • • • • • • • • • •

ALL FRESH AIR UNIT • • • • • • •


FREEDOM OF CHOICE
Because no two spaces are ever quite Color Options
the same, your Hitachi VRF system is Available units: 4-Way, 2-Way, 1-Way Cassettes
Available colors: White, Black, Beige, Grey
customizable with additional features
that work in complete harmony with Motion Sensor
your design. For extra efficiency, wide angle motion sensors can be included with the
following indoor units:
Available units: 4-Way, 4-Way Compact, 2-Way and 1-Way Cassettes,
Ducted High ESP, Ducted Medium ESP, and Ceiling Suspended units

Fresh Air Intake


Optional fresh air intake helps to promote air cleanliness. It is ideal for
schools, hospitals and other buildings that require fresh air ventilation.
Disclaimer
Please note that the features and options listed above must be Available units: 4-Way, 4-Way Compact, 2-Way, 1-Way Cassette, and
ordered in addition to your indoor unit. Ceiling Suspended units

059-082_SMZ_HP_IDU_0614.indd 61 2019/06/14 14:51


KEY INFORMATION
FEATURES TO SUIT YOUR PROJECT SPACE
The new SET FREE Σ range offers our widest choice of indoor units to give you the versatility to complement any interior.

SET FREE Σ – FSNP & FSNS SERIES


CEILING CASSETTE

4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE 2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE
∙ You can distribute air over longer ∙ Made to give you greater design ∙ Motion sensor available for better ∙ Motion sensor available for better
distances with individual four-way flexibility as the dimensions fit energy saving operation energy saving operation
louvers that can accommodate 600mm×600mm architectural ∙ Ideal for a higher ceiling location ∙ Optimum air flow conditions are
optional duct flanges module ceiling specifications for installation (up to 4.6m in created by either downward air
∙M  otion sensor available for better ∙ Quiet operation level (as low as cooling mode) discharge or frontal air discharge
energy saving operation 24.5dB(A)) ∙ Individually operated louvers give (via optional grille)
∙ I deal for a higher ceiling location ∙ Wide range of air flow rate ideal for room occupants more comfort or a combination of both
for installation high ceiling installation with 4.6m ∙ Quiet operation level (as low as ∙ Quiet operation level
(up to 5.5m in cooling mode) air blow down in cooling mode 27dB(A)) (as low as 27dB(A))
∙S  etback temperature control ∙ Setback temperature control ∙ Setback temperature control ∙ Setback temperature control
available, leading to better available, leading to better available, leading to better available, leading to better
operation operation operation operation

DUCTED

HIGH ESP TYPE MEDIUM ESP TYPE SLIM TYPE COMPACT TYPE LARGER AIR VOLUME TYPE
∙ High external static pressure ∙ 3 steps of static pressure ∙Ideal for narrow ceiling voids (BOTH AC MOTOR TYPE AND ∙ Two external static pressure
available: Up to 200Pa for RPI-2.0- (50/100/150 Pa) available installation thanks to low height DC MOTOR TYPE AVAILABLE) settings for better flexibility
6.0FSN3 model, up to 230Pa for ∙ You have more design flexibility up to 192mm & width just 700mm ∙ Ideal for installation over the ∙ High external static pressure:
RPI-8.0/10.0FSN1 model with both rear and bottom air ∙Drain-pump with 900mm lift as closet or windows thanks to Up to 120Pa (140Pa in 7HP class)
∙ Y ou have more design flexibility suction directions available standard optional part the up to the compactness with ∙ Suitable for air distribution for
with both rear and bottom air ∙ Setback temperature control ∙Quiet operation level (as low as 192mm height multiple zone

INDOOR UNITS & VENTILATION


suction directions available available, leading to better 22 dB(A)) ∙ Drain-pump with 900mm lift as
∙S  etback temperature control operation standard optional part
available, leading to better ∙ Quiet operation level (as low as
operation 20dB(A))
∙ Fan air flow rate up to 6 taps (DC
motor model only)

CONCEALED & EXPOSED

FLOOR CONCEALED TYPE FLOOR EXPOSED TYPE FLOOR/CEILING CONVERTIBLE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
∙ When there is no ceiling void, ∙ Easy installation ∙ Each unit can be floor mounted or ∙ Ideal for a higher ceiling ∙ Simple installation procedure
this unit gives you a minimal, ∙ Little installation space required, ceiling suspended (up to 5.6m in cooling) ∙ Flexible discreet design suitable
low visibility option as it can be with only 220mm depth ∙ Easy installation ∙ Better power-saving with optional for any interior
installed in floor cavities and walls ∙ Suitable for installation under a ∙ Fresh air-intake design Motion Sensor ∙ Without expansion-valve model
∙ L ittle installation space required, window, with a 630mm height ∙ Optional drain pump available ∙ Quiet operation level available for 0.6-1.5 for more silent
with only 220mm depth (as low as 28dB(A)) indoor space
∙S  uitable for installation under a ∙ Setback temperature control ∙ Setback temperature control
window, with a 620mm height available, leading to better available, leading to better
operation operation

VENTILATION

TOTAL HEAT EXCHANGER ALL FRESH AIR UNIT


∙ Creates a healthy indoor ∙ Creates a comfortable and healthy
environment thanks to indoor environment thanks to
introducing fresh air function and introducing fresh air function and
ventilation function heat/cool function
∙R emote controller for Total Heat ∙ Various controllers can be selected
Exchanger is equipped in unit as and interfaced with the H-LINK
standard part system
∙ Longer ducts can be connected
on-site, thanks to the higher ESP

61 62

059-082_SMZ_HP_IDU_0614.indd 62 2019/06/14 14:51



LINE UP OVERVIEW
FEATURES COMPARISON

Model 4-WAY 4-WAY 2-WAY 1-WAY HIGH/MEDIUM


CASSETTE CASSETTE CASSETTE CASSETTE ESP TYPE
TYPE COMPACT TYPE TYPE TYPE

RCI-FSN3 RCIM-FSN4 RCD-FSN3 RCS-FSN RPI-FSN3


RPIM-FSN3

Temperature Setting Rate 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C

Indoor Fan Speed 4 taps 4 taps 4 taps 4 taps 4 taps

COMFORT Louver Direction 7 (*4) 7 (*4) 7 (*4) 7 (*5)

Individual Louver Setting • • •


Auto Louver Setting • • •
Cold Draft Prevention Availability (*1) • • • • •
Dry mode Availability • • • • •
Power Saving with Motion Sensor (*2) • • • • •
Outdoor Unit capacity control (*2) Peak cut control • • • • •
POWER-SAVING
(*2) 
moderate control • • • • •
Indoor Unit Rotation Control (*2) Indoor Unit Address • • • • •
Indoor Air Temperature difference • • • • •
Automatic Fan Operation • • • • •
Quick Function • • • • •
Comfort setting Control Cool Air • • • • •
MENU
(*2) 
Daylight Saving Time • • • • •
Power Consumption visualization • • • • •
Weekly Schedule Setting • • • • •
Power-Saving Setting • • • • •
Dirty Filter Notice Availability • • • • •
Check Menu Sensor Condition Check • • • • •
MAINTENANCE Model Display (*2)  • • •
Indoor / Outdoor PCB Check • • • • •
Alarm History Display • • • • •
Colored Decoration Panel availability • (*6)
• (*6)
• (*6)

Motion Sensor P-AP160NAE SOR-NEC SOR-NED SOR-NES SOR-NEZ

OPTIONAL Receiver Kit for wireless remote controller PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHZ1
ACCESSORY
Drain-up mechanism availability • (*3) • (*3) • (*3) • (*3) • (*3)

Fresh air intake design • (*7) • (*7) • (*7) • (*7)


Air filter  F-71L-D1 • (*8) F-90MD-K1 • (*8) F-56/90/160LI
F-160L-D1 F-160MD-K1 B-56/90/160LI
B-160H2 B-90HD
F-160L-K B-160HD
Strainer kit

059-082_SMZ_HP_IDU_0614.indd 63 2019/06/14 14:51


HIGH ESP TYPE SLIM TYPE COMPACT TYPE COMPACT TYPE LARGER AIR FLOOR FLOOR FLOOR/CEILING CEILING WALL MOUNTED
(8/10HP class) (AC) (DC) VOLUME TYPE CONCEALED EXPOSED CONVERTIBLE SUSPENDED TYPE
TYPE TYPE TYPE TYPE

SET FREE Σ – FSNP & FSNS SERIES


RPI-FSN1 RPIZ-FSNQS/P RPIZ-HNATNQ RPIZ-HNDTSQ RPI-FSN2SQ RPFI-FSN2E RPF-FSN2E RPFC-FSNQ RPC-FSN3 RPK-FSN4M
RPK-FSNH4M

0.5°C/1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C 0.5°C/1.0°C 0.5°C/1.0°C

4 taps 3 taps 3 taps 6 taps 3 taps 3 taps 3 taps 3 taps 4 taps 4 taps

7 (*5) 7 (*5) 7 (*5)

• • • • • • • • • •
• • • • • • • • • •
• •
• • •
• • •
• • •
• • •
• • • • • • • • • •
• • •
• • •
• • • • • • • • • •
• • •

INDOOR UNITS & VENTILATION


• • • • • • • • • •
• • •
• • • • • • • • • •
• • • • • • • • • •
• • •
• • • • • • • • • •
• • • • • • • • • •

SOR-NEZ SOR-NEP

PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHP1 PC-ALHZ1

• (*3) • (*3) • (*3) • (*3) • (*3) DUPC-63K1 • (*8)


DUPC-71K1
DUPC-160K1

• (*7)
F-280LI KW-PP5Q KW-PP5Q • (*8)
• (*8)
• (*8)
• (*8) • (*8)
B-280LI KW-PP6Q KW-PP6Q

MSF-NP63A1
MSF-NP112A1
MSF-NP36AH1

(*1) This function is utilized to prevent cold discharged air at start-up of heating operation, after (*5) 5 steps only in the operation of Cooling or Dry.
defrosting operation, etc. The fan speed automatically switches from Slow to Low and then to (*6) 3 colors available except white (Beige, Grey and Black).
the set fan speed. The fan operation might be stopped for up to 2 minutes. At this time the
louver is fixed horizontally. (*7) Optional parts: Duct Adapter is available. please consult your distributor.

(*2) Advanced wired remote controller PC-ARF1 needs to be connected. (*8) Please consult your distributor for the availability.

(*3) Included as standard equipment.


(*4) 7 steps are available by individual louver setting. 5 steps only in the operation of Cooling or Dry.

63 64

059-082_SMZ_HP_IDU_0614.indd 64 2019/06/14 14:51



4-WAY CASSETTE TYPE
(RCI-FSN3)

FEATURES AND BENEFITS

Adaptability Design Flexibility

1) Wide Detection area of motion sensor 1) U


 sed in both narrow ceiling cavity, and with high ceiling
2) Control air flow with individual four-way louvers 2) Standard drain pump with 850mm lift
3) Round ducts can be attached directly
4) T
 he height of the space for installing the unit can be fine-tuned

GENERAL DATA & ACCESSORIES


Model RCI-1.0FSN3 RCI-1.5FSN3 RCI-2.0FSN3 RCI-2.5FSN3 RCI-3.0FSN3 RCI-4.0FSN3 RCI-5.0FSN3 RCI-6.0FSN3
Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW(Btu/h) 2.8(9,600) 4.0(13,600) 5.6(19,100) 7.1(24,200) 8.0(27,300) 11.2(38,200) 14.0(47,800) 16.0(54,600)
Nominal Heating Capacity kW(Btu/h) 3.2(10,900) 4.8(16,400) 6.3(21,500) 8.5(29,000) 9.0(30,700) 12.5(42,600) 16.0(54,600) 18.0(61,400)
Sound Pressure Level dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37
(Overall A Scale) (Hi2/Hi/Me/Lo)
Outer Dimensions Height mm 248 248 248 248 298 298 298 298
Width mm 840 840 840 840 840 840 840 840
Depth mm 840 840 840 840 840 840 840 840
Net Weight kg(lbs.) 20(44) 21(46) 21(46) 22(49) 26(57) 26(57) 26(57) 26(57)
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min. 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22
(Hi2/Hi/Me/Lo) (l/s) (250/217/183/150) (350/283/233/183) (367/283/233/183) (450/383/300/233) (450/383/300/233) (617/517/400/333) (617/550/433/350) (617/583/467/367)
Motor W 57 57 57 57 57 127 127 127
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Gas Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25

Adaptable Panel Model P-AP160NA1 P-AP160NAE


(without Motion Sensor) (with Motion Sensor)
Color Neutral White Neutral White
Outer Height mm 37 37
Dimensions Width mm 950 950
Depth mm 950 950
Net Weight kg(lbs.) 6.5(14) 6.5(14)
Approximate Packing Measurement m3 0.10 0.10

Decoration panel With Motion Sensor P-AP160NAE T-Pipe Connection Kit TKCI-160K
Without Motion Sensor P-AP160NA1 Kit for Deodorant Filter 1.0-2.5 (HP Class) F-71L-D1
Receiver kit Advanced PC-ALH3 & Filter set 3.0-6.0 (HP Class) F-160L-D1
Duct Adapter PD-75A Kit for Deodorant Filter & Filter Box B-160H2
Fresh Air Intake Kit OACI-160K2 Antibacterial Long-life Filter F-160L-K
3-Way Outlet Parts Set PI-160LS1

Notes:
1. The
 cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

059-082_SMZ_HP_IDU_0614.indd 65 2019/06/14 14:51



4-WAY CASSETTE
COMPACT TYPE

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS

Adaptability Design Flexibility

1) Top-class silent operation 1) Compact


2) Aesthetics 2) High Ceiling Available Standard drain-pump
3) Wide Detection area of motion sensor 3) Adopting new antibacterial agent of drain pan

GENERAL DATA & ACCESSORIES


Model RCIM-0.6FSN4 RCIM-0.8FSN4 RCIM-1.0FSN4 RCIM-1.5FSN4 RCIM-2.0FSN4 RCIM-2.5FSN4
Power Supply AC 1Φ, [220-240V/50Hz] [230V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW(Btu/h) 1.6(5,500) 2.2(7,500) 2.8(9,600) 4.0(13,600) 5.6(19,100) 7.1(24,200)
Nominal Heating Capacity kW(Btu/h) 1.9(6,500) 2.5(8,500) 3.2(10,900) 4.8(16,400) 6.3(21,500) 8.5(29,000)
Sound Pressure Level dB(A) 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
(Overall A Scale) (Hi2/Hi/Me/Lo)
Outer Dimensions Height mm 285 285 285 285 285 285

INDOOR UNITS & VENTILATION


Width mm 570 570 570 570 570 570
Depth mm 570 570 570 570 570 570
Net Weight kg(lbs.) 16(35.3) 16(35.3) 16(35.3) 16(35.3) 17(37.5) 17(37.5)
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min. 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
(Hi2/Hi/Me/Lo) (l/s) (353/300/265/212) (388/335/282/212) (424/353/300/212) (459/388/335/247) (530/424/353/282) (565/494/424/353)
Motor W 57 57 57 57 57 57
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25

Adaptable Panel Model P-AP56NAM (without Motion Sensor)


Color Neutral White
Outer Height mm 30
Dimensions Width mm 620
Depth mm 620
Net Weight kg(lbs.) 3(6.6)

Decoration panel P-AP56NAM


Motion Sensor SOR-NEC
Receiver kit PC-ALHC1
Duct Adapter PD-75C

Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

65 66

059-082_SMZ_HP_IDU_0614.indd 66 2019/06/14 14:51



2-WAY CASSETTE TYPE

FEATURES AND BENEFITS

Adaptability Design Flexibility

1) Wide Detection area of motion sensor 1) H


 igh Ceiling Available Standard drain-pump
2) Control air flow with individual louvers 2) The height of the space for installing the unit can be fine-tuned

GENERAL DATA & ACCESSORIES


Model RCD-0.8FSN3 RCD-1.0FSN3 RCD-1.5FSN3 RCD-2.0FSN3 RCD-2.5FSN3 RCD-3.0FSN3 RCD-4.0FSN3 RCD-5.0FSN3 RCD-6.0FSN3
Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW(Btu/h) 2.2(7,500) 2.8(9,600) 4.0(13,600) 5.6(19,100) 7.1(24,200) 8.0(27,300) 11.2(38,200) 14.0(47,800) 16.0(54,300)
Nominal Heating Capacity kW(Btu/h) 2.5(8,500) 3.2(10,900) 4.8(16,400) 6.3(21,500) 8.5(29,000) 9.0(30,700) 12.5(42,600) 16.0(54,600) 18.0(61,400)
Sound Pressure Level dB(A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39
(Overall A Scale) (Hi2/Hi/Me/Lo)
Outer Dimensions Height mm 298 298 298 298 298 298 298 298 298
Width mm 860 860 860 860 860 860 1,420 1,420 1,420
Depth mm 630 630 630 630 630 630 630 630 630
Net Weight kg(lbs.) 23(50.7) 23(50.7) 25(55.1) 25(55.1) 25(55.1) 25(55.1) 39(86.0) 39(86.0) 39(86.0)
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min. 10/9/ 11/9.5/ 15/13/ 16.5/14.5/ 18.5/16.5/ 21/18.5/ 30/26.5/ 35/31/ 37/32.5/
(Hi2/Hi/Me/Lo) (l/s) 7.5/6.5 8.5/7 11.5/10 12.5/10.5 14.5/12.5 16/12.5 23/20 27/21 28.5/24
(353/318/ (388/335/ (530/459/ (583/512/ (653/583/ (742/653/ (1,059/936/ (1,236/1,095/ (1,306/1,147/
265/230) 300/247) 406/353) 441/371) 512/441) 565/441) 812/706) 953/742) 1,006/847)
Motor W 57 57 57 57 57 57 57×2 57×2 57×2
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.24 0.24 0.24 0.24 0.24 0.24 0.36 0.36 0.36

Adaptable Panel Model P-AP90DNA (for 2.2~8.0kW) P-AP160DNA (for 11.2~16.0kW)


Color Neutral White Neutral White
Outer Height mm 30 30
Dimensions Width mm 1,100 1,660
Depth mm 710 710
Net Weight kg(lbs.) 7.5(16.5) 10.5(23.2)
Approximate Packing Measurement m3 0.13 0.2

Decoration panel 0.8-3.0 (HP Class) P-AP90DNA Antibacterial 0.8-3.0 (HP Class) F-90MD-K1
4.0-6.0 (HP Class) P-AP160DNA Long-life Filter 4.0-6.0 (HP Class) F-160MD-K1
Receiver kit PC-ALHD1 Filter Box 0.8-3.0 (HP Class) B-90HD
Motion Sensor SOR-NED 4.0-6.0 (HP Class) B-160HD
Duct Adapter PD-150D

Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

059-082_SMZ_HP_IDU_0614.indd 67 2019/06/14 14:51



1-WAY CASSETTE TYPE

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS

Adaptability Design Flexibility

1) Wide Detection area of motion sensor 1) 3 installation types selectable


2) Quiet operation 2) High Ceiling Available Standard drain-pump

GENERAL DATA & ACCESSORIES


Model RCS-0.8FSN RCS-1.0FSN RCS-1.5FSN RCS-2.0FSN RCS-2.5FSN RCS-3.0FSN
Power Supply AC 1Φ, [220-240V/50Hz] [230V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW(Btu/h) 2.2(7,500) 2.8(9,600) 4.0(13,600) 5.6(19,100) 7.1(24,200) 8.0(27,300)
Nominal Heating Capacity kW(Btu/h) 2.5(8,500) 3.2(10,900) 4.8(16,400) 6.3(21,500) 8.5(29,000) 9.0(30,700)
Sound Pressure Level dB(A) 34/32/29/27 36/34/31/28 40/37/33/31 42/38/35/31 43/39/36/32 43/40/37/33
(Overall A Scale) (Hi2/Hi/Me/Lo)
Outer Dimensions Height mm 235 235 235 235 235 235

INDOOR UNITS & VENTILATION


Width mm 900 900 900 900 1,210 900
Depth mm 710 710 710 710 710 710
Net Weight kg(lbs.) 25(55.1) 25(55.1) 26(57.3) 26(57.3) 33(72.8) 33(72.8)
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min. 8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
(Hi2/Hi/Me/Lo) (l/s) (300/265/229/212) (335/300/265/229) (459/406/353/300) (512/459/388/335) (653/582/512/424) (706/618/547/459)
Motor W 50 50 50 50 80 80
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.25 0.25 0.25 0.25 0.32 0.32

Adaptable Panel Model P-AP36CNA (for RCS-[0.8-1.0]FSN) P-AP56CNA (for RCS-[1.5-2.0]FSN) P-AP80CNA (for RCS-[2.5-3.0]FSN)
Color Neutral White Neutral White Neutral White
Outer Height mm 35 35 35
Dimensions Width mm 1,100 1,100 1,410
Depth mm 800 800 800
Net Weight kg(lbs.) 4.5(9.9) 4.5(9.9) 6(13.2)
Approximate Packing Measurement m3 0.098 0.098 0.125

Decoration panel 0.8-1.0 (HP Class) P-AP36CNQ Drille for Front Discharge 0.8-2.0 (HP Class) DG-56SW1
1.5-2.0 (HP Class) P-AP56CNA 2.5-3.0 (HP Class) DG-80SW1
2.5-3.0 (HP Class) P-AP80CNA Air Outlet Shutter Plate 0.8-2.0 (HP Class) PIS-56LS
Receiver kit PC-ALHS1 2.5-3.0 (HP Class) PIS-80LS
Motion Sensor SOR-NES
Duct Adapter PD-100

Notes:
1. The
 cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure level is based on following conditions.
1.5 metre Beneath the Unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

67 68

059-082_SMZ_HP_IDU_0614.indd 68 2019/06/14 14:51



HIGH ESP TYPE
(EXTERNAL STATIC PRESSURE TYPE)

FEATURES AND BENEFITS


Fits a standard drain pump with Air Inlet can be chosen from two
850 mm lift locations

∙ Setback temperature control available, leading to better


operation Rear
drain lift: Air Inlet
∙ Dual set-point for greater simultaneous cooling & heating
850mm
operation
Bottom Air Inlet

GENERAL DATA & ACCESSORIES


Model RPI-2.0FSN3 RPI-2.5FSN3 RPI-3.0FSN3 RPI-4.0FSN3 RPI-5.0FSN3 RPI-6.0FSN3 RPI-8.0FSN1 RPI-10.0FSN1
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW 5.6 7.1 8.0 11.2 14.0 16.0 22.4 28.0
Nominal Heating Capacity kW 6.3 8.5 9.0 12.5 16.0 18.0 25.0 31.5
Sound Pressure Level dB(A) 41/38/35/32 37/35/32/30 39/36/33/31 40/37/34/32 42/39/36/33 44/40/37/34 44/40/37/34 44/40/37/34
(Overall A Scale)(Hi2/Hi/Me/Lo)
Sound Power Level dB(A) 59/56/53/50 55/53/50/48 57/54/51/49 58/55/52/50 60/57/54/51 62/58/55/52 45/43/40/36 50/48/46/39
(Overall A Scale)(Hi2/Hi/Me/Lo)
Outer Height mm 300 300 300 300 300 300 470 470
Dimensions Width mm 700 1,050 1,050 1,400 1,400 1,400 1,380 1,380
Depth mm 800 800 800 800 800 800 1,060 1,060
Net Weight kg 29 38 38 48 48 48 94 94
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min 14.5/13/11/9.5 18.5/16.5/14.5/12 20/17.5/15.5/13 30/26.5/23/20 33.5/29.5/26/22 36/31.5/27.5/24 63/58/50/38 80/72/64/48
(Hi2/Hi/Me/Lo) (cfm) (512/459/ (653/582/ (706/618/ (1,059/935/ (1,182/1,041/ (1,270/1,112/ (2,224/2,048/ (2,825/2,542/
388/335) 512/423) 547/459) 812/706) 917/776) 970/847) 1,765/1,341) 2,260/1,695)
External Pressure (*3) Pa 50(100-200) 50(100-200) 50(100-200) 50(100-200) 50(100-200) 50(100-200) 50(100-230) 50(100-230)
Motor W 157 190 190 259 259 259 840 840
Connections m3 Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.28 0.39 0.39 0.5 0.5 0.5 0.97 0.97

Receiver kit Advanced PC-ALHZ1 Filter Box for 0.8-2.0 (HP Class) B-56LI
Motion Sensor SOR-NEZ Long-Life Filter 2.5-3.0 (HP Class) B-90LI
Condensate Drain Pump Kit - (included as standard equipment) 4.0-6.0 (HP Class) B-160LI
Antifungal Long-Life Filter 0.8-2.0 (HP Class) F-56LI Long-Life Filter Kit/ 8-10 (HP Class) F-280LI
2.5-3.0 (HP Class) F-90LI Long-Life Filter
4.0-6.0 (HP Class) F-160LI MotioFilter Boxn Sensor 8-10 (HP Class) B-280LI

Notes:
1. The nominal cooling capacity is the combined capacity of the Hitachi standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return
Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V. The above data was measured in an anechoic chamber
so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting (High Pressure Setting1 - High Pressure Setting2)” values
when a filter is not used. The sound pressure level is based on the Standard Pressure Setting.

059-082_SMZ_HP_IDU_0614.indd 69 2019/06/14 14:51



MEDIUM ESP TYPE
(EXTERNAL STATIC PRESSURE TYPE)

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS
Fits a standard drain pump with Air Inlet can be chosen from two
850 mm lift locations

∙ Setback temperature control available, leading to better


operation Rear
drain lift: Air Inlet
∙ Dual set-point for greater simultaneous cooling & heating
850mm
operation
Bottom Air Inlet

GENERAL DATA & ACCESSORIES


Model RPIM-0.8FSN3 RPIM-1.0FSN3 RPIM-1.5FSN3 RPIM-2.0FSN3 RPIM-2.5FSN3 RPIM-3.0FSN3 RPIM-4.0FSN3 RPIM-5.0FSN3 RPIM-6.0FSN3
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling Capacity kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Heating Capacity kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound Pressure Level dB(A) 32/30/28/27 33/31/29/28 38/35/32/30 40/37/34/31 37/35/33/31 38/36/33/31 40/38/35/32 42/39/36/34 43/40/37/34
(Overall A Scale)(Hi2/Hi/Me/Lo)
Sound Power Level dB(A) 50/48/46/45 51/49/47/46 56/53/50/48 58/55/52/49 55/53/51/49 56/54/51/49 58/56/53/50 60/57/54/52 61/58/55/52

INDOOR UNITS & VENTILATION


(Overall A Scale)(Hi2/Hi/Me/Lo)
Outer Height mm 250 250 250 250 250 250 250 250 250
Dimensions Width mm 700 700 700 700 1,050 1,050 1,400 1,400 1,400
Depth mm 800 800 800 800 800 800 800 800 800
Net Weight kg 26 26 27 27 36 36 44 44 44
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min 8.5/7.5/6.5/5.5 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14/1220/17.5/15.5/13 30/26.5/23/20 33.5/29.5/26/22 36/31.5/27.5/24
(Hi2/Hi/Me/Lo) (cfm) (300/265/ (335/300/ (459/406/ (512/459/ (653/582/ (706/618/ (1,059/935/ (1,182/1,041/ (1270/1,112/
229/194) 265/229) 353/300) 388/335) 494/423) 547/459) 812/706) 917/776) 970/847)
External Pressure (*3) Pa 50(100-150) 50(100-150) 50(100-150) 50(100-150) 50(100-150) 50(100-150) 50(100-150) 50(100-150) 50(100-150)
Motor W 157 157 157 157 190 190 259 259 259
Connections m3 Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.24 0.24 0.24 0.24 0.33 0.33 0.42 0.42 0.42

Receiver kit Advanced PC-ALHZ1 Filter Box for 0.8-2.0 (HP Class) B-56LI
Motion Sensor SOR-NEZ Long-Life Filter 2.5-3.0 (HP Class) B-90LI
Condensate Drain Pump Kit - (included as standard equipment) 4.0-6.0 (HP Class) B-160LI
Antifungal Long-Life Filter 0.8-2.0 (HP Class) F-56LI
2.5-3.0 (HP Class) F-90LI
4.0-6.0 (HP Class) F-160LI

Notes:
1. The nominal cooling capacity is the combined capacity of the Hitachi standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return
Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V. The above data was measured in an anechoic chamber
so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting (High Pressure Setting1 - High Pressure Setting2)” values when
a filter is not used. The sound pressure level is based on the Standard Pressure Setting.

69 70

059-082_SMZ_HP_IDU_0614.indd 70 2019/06/14 14:51



SLIM TYPE

FEATURES AND BENEFITS


Fits a standard drain pump with Air Inlet can be chosen from two
850 mm lift locations

∙ Ideal for narrow ceiling voids installation thanks to low


height up to 192mm & width just 700mm Rear
drain lift: Air Inlet
∙ Drain-pump with 900mm lift as standard optional part
850mm
∙ Quiet operation level (as low as 22dB(A))
Bottom Air Inlet

GENERAL DATA & ACCESSORIES


Model RPIZ-0.8FSNQS/P RPIZ-1.0FSNQS/P RPIZ-1.3FSNQS/P RPIZ-1.5FSNQS/P
Indoor Unit Power Supply AC 1Φ, [220V/50Hz]
Nominal Cooling Capacity kW 2.3 2.9 3.8 4.4
kcal/h 2,000 2,500 3,300 3,800
Btu/h 7,900 9,900 13,000 15,100
Nominal Heating Capacity kW 2.8 3.3 4.2 4.9
kcal/h 2,400 2,800 3,600 4,200
Btu/h 9,500 11,100 14,300 16,700
Sound Pressure Level dB(A) 27/24/21 27/24/21 31/29/27 31/29/27
(Overall A Scale)(Hi/Me/Lo)
Outer Height mm 192 192 192 192
Dimensions Width mm 700 700 700 700
Depth mm 602 602 602 602
Net Weight kg 21 21 21 21
Refrigerant R410A(Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan Air Flow Rate m3/min 8/7/6 8/7/6 10/8/7 10/8/7
(Hi2/Hi/Me/Lo) (cfm)
External Pressure (*3) Pa 10/30 10/30 10/30 10/30
Motor W 15 15 25 25
3
Connections m Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
Piping Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
Condensate Drain VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.15 0.15 0.15 0.15

Receiver kit Advanced PC-ALHZ1


Condensate Drain Pump Kit - (included as standard equipment)
Notes:
1. The nominal cooling capacity is the combined capacity of the Hitachi standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1 metre Beneath the Unit and 1 metre from Discharge Grille. Voltage of
the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1
dB(A). The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. (*3) In case of using R407C or R22, use the accessory adaptor and Φ19.05 piping.

059-082_SMZ_HP_IDU_0614.indd 71 2019/06/14 14:51



COMPACT TYPE
(AC MOTOR TYPE)

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS

∙ Ideal for installation over the closet or windows thanks to


the up to the compactness with 192mm height
∙ Drain-pump with 900mm lift as standard optional part
∙ Quiet operation level (as low as 21dB(A))
∙ Fan air flow rate up to 6 taps (DC motor model only)

Over the closet In dropped ceiling, over window

GENERAL DATA & ACCESSORIES


Model RPIZ-0.8HNATNQ RPIZ-1.0HNATNQ RPIZ-1.3HNATNQ RPIZ-1.5HNATNQ RPIZ-1.8HNATNQ RPIZ-2.0HNATNQ RPIZ-2.3HNATNQ RPIZ-2.5HNATNQ
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]
Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3  7.1
Capacity Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Sound Pressure (Hi/Me/Lo) dB(A) 30/23/20 30/23/20 34/25/22 32.5/26/23 34/26/25 34/26/25 37/29/27 37/29/27
Level
Outer Height mm 192 192 192 192 192 192 192 192

INDOOR UNITS & VENTILATION


Dimensions Width mm 700 700 700 910 1,180 1,180 1,180 1,180
Depth mm 447 447 447 447 447 447 447 447
Net Weight kg 17 17 17 21 27 27 28 28
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan Air Flow(Hi2/Hi/Me/Lo) m3/min 9.5/6.5/5.5 9.5/6.5/5.5 9.5/6.5/5.5 10/7/6 15/10/9 15/10/9 17/10/9 17/10/9
Rate
External Pressure (*3) Pa 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30)
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18

Receiver kit Advanced PC-ALHZ1


Condensate Drain Pump Kit - (included as standard equipment)
Air filter 0.8-1.5 (HP Class) KW-PP5Q
1.8-2.5 (HP Class) KW-PP6Q

Notes:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting values when a filter is not used.

71 72

059-082_SMZ_HP_IDU_0614.indd 72 2019/06/14 14:51



COMPACT TYPE
(DC MOTOR TYPE)

FEATURES AND BENEFITS

∙ Ideal for installation over the closet or windows thanks to


the up to the compactness with 192mm height
∙ Drain-pump with 900mm lift as standard optional part
∙ Quiet operation level (as low as 21dB(A))
∙ Fan air flow rate up to 6 taps (DC motor model only)

Over the closet In dropped ceiling, over window

GENERAL DATA & ACCESSORIES


Model RPIZ-0.8HNDTSQ RPIZ-1.0HNDTSQ RPIZ-1.3HNDTSQ RPIZ-1.5HNDTSQ RPIZ-1.8HNDTSQ RPIZ-2.0HNDTSQ RPIZ-2.3HNDTSQ RPIZ-2.5HNDTSQ
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3  7.1
Capacity Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Sound Pressure (6 taps) dB(A) 33/31/28/ 33/31/28/ 33/31/28/ 31/30/28/ 36/33.5/31/ 36/33.5/31/ 36/33.5/31/ 36/33.5/31/
Level 25/23.5/22.5 25/23.5/22.5 25/23.5/22.5 25/22/20 28/24.5/22.5 28/24.5/22.5 28/24.5/22.5 28/24.5/22.5
Outer Height mm 192 192 192 192 192 192 192 192
Dimensions Width mm 700 700 700 910 1,180 1,180 1,180 1,180
Depth mm 447 447 447 447 447 447 447 447
Net Weight kg 17 17 17 20 24 24 24 24
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan Air Flow(6 taps) m3/min 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5 10/9/8/7.5/6.5/6 16.5/15/13/ 16.5/15/13/ 16.5/15/13/ 16.5/15/13/
Rate 12/10/9 12/10/9 12/10/9 12/10/9
External Pressure (*3) Pa 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-50) 10(0-10-50) 10(0-10-50) 10(0-10-50)
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18

Receiver kit Advanced PC-ALHZ1


Condensate Drain Pump Kit - (included as standard equipment)
Air filter 0.8-1.5 (HP Class) KW-PP5Q
1.8-2.5 (HP Class) KW-PP6Q

Notes:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates “Standard Pressure Setting values when a filter is not used.

059-082_SMZ_HP_IDU_0614.indd 73 2019/06/14 14:51



LARGER AIR VOLUME
TYPE

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS Flexible installation options allow for multiple configurations
L-shaped space U-shaped space

∙ Two external static pressure settings for better flexibility


∙ High external static pressure:
Up to 120Pa (140Pa in 7HP class)
∙ Suitable for air distribution for multiple zone

GENERAL DATA & ACCESSORIES


Model RPI-3.0FSN2SQ RPI-4.0FSN2SQ RPI-5.0FSN2SQ RPI-6.0FSN2SQ RPI-7.0FSN2SQ
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz] AC 1Φ, [240V/50Hz]
Nominal Cooling Capacity kW 8.0 11.2 14.0 16.0 18.0
Nominal Heating Capacity kW 9.0 12.5 16.0 18.0 20.0
Sound Pressure High Pressure dB(A) 46/44/40 48/45/41 49/46/43 53/49/45 51/47/42
Level Setting
(Overall A Scale) Standard Pressure dB(A) 45/43/39 47/44/40 48/45/42 52/48/44 -

INDOOR UNITS & VENTILATION


(Hi/Me/Lo) Setting
Outer Height mm 350 350 350 350 440
Dimensions Width mm 1,076 1,076 1,300 1,300 1,430
Depth mm 800 800 800 800 550
Net Weight kg 52 57 61 63 75
Refrigerant R410A
Indoor Fan High Pressure m3/min 29/26/20(483/433/333) 36/33/25(600/550/417) 47/43/34(783/717/567) 56/50/40(933/833/667) 65/57/46(1,083/950/767)
Setting (l/s)
Air Flow Rate Standard Pressure m3/min 29/26/20(483/433/333) 36/29/25(600/483/417) 47/39/36(783/650/600) 56/48/42(933/800/700) -
(Hi2/Hi/Me/Lo) Setting (l/s)
External Pressure (*1) Pa 120(70) 120(70) 120(70) 120(70) 140
Motor Output W 250 300 420 550 650
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52
Piping Gas Line mm Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25
Approximate Packing Measurement m3 0.49 0.49 0.57 0.57 0.54

Receiver kit Advanced PC-ALHZ1

Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Voltage
of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2 dB(A). The data
in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*1) indicates “High Pressure Setting (Standard Pressure Setting)” values when a filter is not used. The sound pressure level is
based on the Standard Pressure Setting.

73 74

059-082_SMZ_HP_IDU_0614.indd 74 2019/06/14 14:51



FLOOR CONCEALED TYPE

FEATURES AND BENEFITS

Design Flexibility Air Outlet

Cavity that
conceals
Blends unobtrusively with any interior décor: only the suction and the unit
discharge grilles are visible.
Its low height (only 620mm) enables the unit to fit perfectly beneath

620mm
a window.
Requires little installation space thanks to its slim 202mm depth.
900-1,170mm
Air Inlet

202mm

GENERAL DATA & ACCESSORIES


Model RPFI-1.0FSN2E RPFI-1.5FSN2E RPFI-2.0FSN2E RPFI-2.5FSN2E
Power Supply Current AC 1 Phase
V/Hz [220-240/50] [220/60]
Nominal Cooling Capacity kW 2.8 4.0 5.6 7.1
Nominal Heating Capacity kW 3.2 4.8 6.3 8.5
Sound Pressure Level (Hi/Me/Lo) dB(A) 35/32/29 38/35/31 39/36/32 42/38/34
Outer Height mm 620 620 620 620
Dimensions Width mm 848 973 1,223 1,223
Depth mm 220 220 220 220
Net Weight kg 19 23 27 28
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min 8.5/7/6 12/10/09 16/14/11 16/14/11
(Hi/Me/Lo)
Motor W 20 28 45 45
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88
Condensate Drain VP25
Packaging Volume m3 0.22 0.23 0.25 0.25

Receiver kit Advanced PC-ALHZ1

Notes:
1. The cooling and heating capacities above show the maximum capacities when outdoor and indoor temperatures are under the following conditions:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on the following conditions:
1 metre from the unit.
1 metre from floor level.
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber.
Reflected sound should be considered prior to installation


For full specifications, please refer to the Technical Catalog.

059-082_SMZ_HP_IDU_0614.indd 75 2019/06/14 14:51



FLOOR EXPOSED TYPE

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS

Design Flexibility

Floor Exposed units can be installed with a minimum of disruption


to walls and floors, making them an excellent retrofitting option. The
220mm depth means that little installation space is required. With Air Outlet
a total height of up to 630mm, they are well suited to installation
beneath a window.
Air Inlet
1,045mm

GENERAL DATA & ACCESSORIES


Model RPF-1.0FSN2E RPF-1.5FSN2E RPF-2.0FSN2E RPF-2.5FSN2E
Power Supply Current AC 1 Phase
V/Hz [220-240/50] [220/60]
Nominal Cooling Capacity kW 2.8 4.0 5.6 7.1

INDOOR UNITS & VENTILATION


Nominal Heating Capacity kW 3.2 4.8 6.3 8.5
Sound Pressure Level (Hi/Me/Lo) dB(A) 35/32/29 38/35/31 39/36/32 42/38/34
Color Spring White
Outer Height mm 630 630 630 630
Dimensions Width mm 1,045 1,170 1,420 1,420
Depth mm 220 220 220 220
Net Weight kg 25 28 33 34
Refrigerant R410A
Indoor Fan Air Flow Rate m3/min 8.5/7/6 12/10/09 16/14/11 16/14/11
(Hi/Me/Lo)
Motor W 20 28 45 45
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88
Condensate Drain Φ 18.5 OD
Packaging Volume m3 0.22 0.24 0.29 0.29

Receiver kit Advanced PC-ALHZ1

Notes:
1. T
 he cooling and heating capacities above show the maximum capacities when outdoor and indoor temperatures are under the following conditions:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure level is based on the following conditions:
1 metre from the unit.
1 metre from floor level.
Voltage of the power source for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber.
Reflected sound should be considered prior to installation


For full specifications, please refer to the Technical Catalog.

75 76

059-082_SMZ_HP_IDU_0614.indd 76 2019/06/14 14:51



FLOOR/CEILING
CONVERTIBLE TYPE

FEATURES AND BENEFITS

Adapts to both floor and ceiling New air-intake design

⟦CEILING USE⟧ ⟦FLOOR USE⟧ Equipped with air-intakes, the unit connects
Supplies air to a wide area. Smaller footprint: Only 230mm in depth. with ventilations such as a Total Heat
Exchanger using a duct, providing better
High ceiling use capability. Suitable for installation beneath a window
interior air quality.
thanks to the 680mm height.

GENERAL DATA & ACCESSORIES


Model RPFC-1.8FSNQ RPFC-2.0FSNQ RPFC-2.3FSNQ RPFC-2.5FSNQ RPFC-3.0FSNQ RPFC-3.3FSNQ RPFC-4.0FSNQ RPFC-5.0FSNQ
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling kW 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2
Capacity Heating kW 5.6 6.5 7.5 8.5 9.6 10.0 13.0 16.3
Sound Pressure Ceiling Mode dB(A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42
Level Floor Mode dB(A) 43/38/35 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43 55/50/46
Outer (H×W×D) mm 230×990×680 230×990×680 230×990×680 230×990×680 230×1,285×680 230×1,285×680 230×1,285×680 230×1,580×680
Dimensions
Net Weight kg 31 31 32 32 39 40 41 47
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan (Hi/Me/Lo) m3/min 780/660/540 780/660/540 966/840/678 966/840/678 1,092/912/732 1,164/978/798 1,488/1,230/978 1,980/1,680/1,380
Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.31 0.31 0.31 0.31 0.40 0.40 0.40 0.48

Receiver kit Advanced PC-ALHZ1

Notes:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.0 metre Beneath the unit.
1.0 metre from Discharge grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

059-082_SMZ_HP_IDU_0614.indd 77 2019/06/14 14:51



CEILING SUSPENDED
TYPE

SET FREE Σ – FSNP & FSNS SERIES


FEATURES AND BENEFITS
Adaptability Design Flexibility
1) Wide Detection area of
2) Auto louver Suitable for high ceiling space
motion sensor (SOR-NEP)
(Optional part) to achieve better energy- Soften the discomfort by temperature Thanks to 5.6m cooling air blow down
saving irregularity and cold draft

GENERAL DATA & ACCESSORIES


Model RPC-1.5FSN3 RPC-2.0FSN3 RPC-2.5FSN3 RPC-3.0FSN3 RPC-4.0FSN3 RPC-5.0FSN3 RPC-6.0FSN3
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling kW 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Capacity Heating kW 4.8 6.3 8.5 9.0 12.5 16.0 18.0

INDOOR UNITS & VENTILATION


Sound Pressure (Hi2/Hi/Me/Lo) dB(A) 37/35/31/28 38/35/31/28 38/35/31/28 40/37/33/29 44/42/37/32 48/45/41/35 49/47/42/36
Level
Color Neutral White
Outer (H×W×D) mm 235×960×690 235×960×690 235×1,270×690 235×1,270×690 235×1,580×690 235×1,580×690 235×1,580×690
Dimensions
Net Weight kg 26 27 35 35 41 41 41
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Indoor Fan (Hi2/Hi/Me/Lo) m3/min 15/13/11/9 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21
Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP20 VP20 VP20 VP20 VP20 VP20 VP20
Approximate Packing Volume m3 0.23 0.23 0.31 0.31 0.38 0.38 0.38

Receiver kit Advanced PC-ALHP1


Motion Sensor SOR-NEP
Condensate 1.5 (HP Class) DUPC-63K1
Drain Pump Kit 2.0 (HP Class) DUPC-71K1
2.5-6.0 (HP Class) DUPC-160K1

Notes:
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. T
 he sound pressure level is based on following conditions.
1.0 metre Beneath the unit.
1.0 metre from Discharge grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

77 78

059-082_SMZ_HP_IDU_0614.indd 78 2019/06/14 14:51



WALL MOUNTED TYPE

FEATURES AND BENEFITS


Simple installation procedure To ensure quieter environment Easy maintenance
Refrigerant piping can be connected from "External Expansion Valve Type" are suitable for Front flat panel keeps the unit from dust and
the rear, base, or left of the unit, providing hotel rooms or residences where background facilitates maintenance work. The front grille
much greater flexibility for piping and noise is lower. To minimize the continuous hinges open easily—no tools are needed to
selection of installation sites. refrigerant running noise, You can install the gain quick access to the filter. The filter can
expansion valve away from the unit. be removed and cleaned as required.

GENERAL DATA & ACCESSORIES


Type Expansion Valve built-in type External Expansion Valve type
Model RPK-0.6 RPK-0.8 RPK-1.0 RPK-1.5 RPK-2.0 RPK-2.5 RPK-3.0 RPK-4.0 RPK-0.6 RPK-0.8 RPK-1.0 RPK-1.5
FSN4M FSN4M FSN4M FSN4M FSN4M FSN4M FSN4M FSN4M FSNH4M FSNH4M FSNH4M FSNH4M
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz] AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Nominal Cooling kW 1.7 2.2 2.8 4.0 5.6 7.1 8.0 11.2 1.7 2.2 2.8 4.0
Capacity Heating kW 1.9 2.5 3.2 4.8 6.3 8.5 9.0 12.5 1.9 2.5 3.2 4.8
Sound Pressure (Hi2/Hi/Me/Lo) dB(A) 35/32/ 39/35/ 39/35/ 46/40/ 40/37/ 45/42/ 47/44/ 51/48/ 35/32/ 39/35/ 39/35/ 46/40/
Level 31/29 32/30 32/30 36/33 34/31 38/35 40/35 44/39 31/29 32/30 32/30 36/33
Color White White
Outer (H×W×D) mm 300×790 300×790 300×790 300×900 300×1,100 300×1,100 300×1,100 300×1,100 300×790 300×790 300×790 300×900
Dimensions ×230 ×230 ×230 ×230 ×260 ×260 ×260 ×260 ×230 ×230 ×230 ×230
Net Weight kg 10 10 10 11 14.5 15 15 15 10 10 10 11
Refrigerant R410A R410A
Indoor Fan (Hi2/Hi/Me/Lo) m3/min 8/7.5/ 10/8/ 10/8/ 14/11/ 14.5/13/ 18.5/16.5/ 20/17.5/ 23/20/ 8/7.5/ 10/8/ 10/8/ 14/11/
Air Flow Rate 7/6 7/6.5 7/6.5 9/7.5 11/9.5 14/12 15.5/12.5 17.5/14.5 7/6 7/6.5 7/6.5 9/7.5
Motor W 38 38 38 38 38 38 38 38 38 38 38 38
Connections Flare-Nut Connection (with Flare Nuts) Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ12.7 Φ12.7 Φ12.7 Φ12.7
Condensate Drain VP16 VP16
Approximate Packing Volume m3 0.09 0.09 0.09 0.11 0.14 0.14 0.14 0.14 0.09 0.09 0.09 0.11
Accessory included Wall Mounting Bracket Wall Mounting Bracket

Receiver kit Advanced PC-ALHZ1 STRAINER KIT


Strainer kit (*) FSN4M: MSF-NP63A1 Strainer Kit Refrigerant Pipe
0.8-2.3 (HP Class)
FSN4M: MSF-NP112A1
2.5-4.0 (HP Class)
FSNH4M: MSF-NP36AH1
0.8-2.3 (HP Class)
External Expansion Valve Kit FSNH4M EV-1.5N1 solid foreign filter
substances
* We recommend to install STRAINER KIT with VRF Wall mounted unit, to ensure that any trouble of condensation drop can be avoided.
A strainer kit ensures that solid foreign
substances, like small particles of metal, are
Notes:
caught before they enter the electric expansion
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the
valves of a wall-mounted indoor unit.
following conditions.
Without the strainer kit’s filter, these particles
Cooling Operation Conditions Heating Operation Conditions
may prevent the valves from being fully sealed,
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
creating a risk of explosive condensation when
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
the unit becomes active.
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The sound pressure level is based on following conditions.
1.0 metre Beneath the Unit.
1.0 metre from Discharge Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

059-082_SMZ_HP_IDU_0614.indd 79 2019/06/14 14:51


059-082_SMZ_HP_IDU_0614.indd 80
79
80
INDOOR UNITS & VENTILATION SET FREE Σ – FSNP & FSNS SERIES

2019/06/14 14:51

VENTILATION

TOTAL HEAT EXCHANGER

Model KPI-2521 KPI-5021 KPI-8021 KPI-10021 (*1)

Unit Power Supply AC 1Φ, [220-240V/50Hz]

Air Flow Rate (Hi/Me/Lo) m3/h 250/250/165 500/500/350 800/800/670 1,000/1,000/870

External Pressure (Hi/Me/Lo) Pa 65/40/20 150/60/30 140/100/70 160/100/80

Temp. Exchange (Hi/Me/Lo) % 78/78/83 77/77/82 78/78/80.5 79/79/81


Efficiency

Enthalpy For Heating % 69/69/74 67/67/73 71/71/73 70/70/73


Exchange (Hi/Me/Lo)
Efficiency
For Cooling % 62.5/62.5/68 61.5/61.5/68 64.5/64.5/68 64.5/64.5/67
(Hi/Me/Lo)

Sound Pressure at 1.5m dB(A) 26.5-27.5/25-26/21-22 32.5-33.5/30-31/23.5-24.5 33.5-34.5/32-33/30-31 36-37/34-35/31.5-32.5


Level from the unit
(Over A Scale) (under)
(Hi/Me/Lo) (*2)(*4)

at Air Outlet dB(A) 33.5-34.5/32-33/26-27 40.5-41.5/38-39/29.5-30.5 44.5-45.5/43-44/40-41 47-48/45-46/41.5-42.5


(Hi/Me/Lo) (*3)(*4)

Outer Height mm 275 317 398 398


Dimensions
Width mm 735 1,016 1,004 1,231

Depth mm 780 888 1,164 1,164

Net Weight kg(lbs.) 21(46) 33(73) 61(134) 72(159)

Connection Duct Diameter mm Φ150 Φ200 Φ250 Φ250

Model KPI-2521 KPI-5021 KPI-8021 KPI-10021 (*1)

Unit Power Supply AC 1Φ, [220/60Hz]

Air Flow Rate (Hi/Me/Lo) m3/h 250/250/150 500/500/300 800/800/660 1,000/1,000/720

External Pressure (Hi/Me/Lo) Pa 100/50/20 200/60/20 230/120/80 200/110/60

Temp. Exchange (Hi/Me/Lo) % 78/78/84 77/77/83.5 78/78/81 79/79/83


Efficiency

Enthalpy For Heating % 69/69/75 67/67/75 71/71/73.5 70/70/76


Exchange (Hi/Me/Lo)
Efficiency
For Cooling % 62.5/62.5/70 61.5/61.5/70 64.5/64.5/68.5 64.5/64.5/71
(Hi/Me/Lo)

Sound Pressure at 1.5m dB(A) 28.5/25.5/21 32.5/28.5/23 35/31/29 36/34/30


Level from the unit
(Over A Scale) (under)
(Hi/Me/Lo) (*2)(*4)

at Air Outlet dB(A) 35.5/32.5/26 40.5/36.5/29 46/42/39 47/45/40


(Hi/Me/Lo) (*3)(*4)

Outer Height mm 275 317 398 398


Dimensions
Width mm 735 1,016 1,004 1,231

Depth mm 780 888 1,164 1,164

Net Weight kg(lbs.) 21(46) 33(73) 61(134) 72(159)

Connection Duct Diameter mm Φ150 Φ200 Φ250 Φ250

Notes:
(*1):KPI-10021 has different units according to the applied power supply, 220-240V/50Hz and 220V/60Hz.
(*2):The sound pressure level is based on following conditions.
1.5 metre beneath the unit and this data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
(*3):The noise at the air outlets is the values at a 45° angle, 1.5 metre in front of the unit.
(*4):The sound pressure level is based on the total heat exchange mode.
In case of the bypass ventilation mode, the sound pressure level increase by approximately 1 dB(A).

059-082_SMZ_HP_IDU_0614.indd 81 2019/06/14 14:51


ALL FRESH AIR UNIT

SET FREE Σ – FSNP & FSNS SERIES


Model RPI-5.0KFNQ RPI-8.0KFNQ RPI-10.0KFNQ RPI-12.0KFNQ
Unit Power Supply AC 1Φ, AC 1Φ, AC 1Φ, AC 1Φ, AC 1Φ, AC 1Φ, AC 1Φ, AC 1Φ,
[220-240V/50Hz] [220V/60Hz] [220-240V/50Hz] [220V/60Hz] [220-240V/50Hz] [220V/60Hz] [380-415V/50Hz] [380V/60Hz]
Connectable Outdoor Unit SET FREE Σ Heat Pump Type FSNS/FSNP Series RAS-12FSNS/P
Cooling Capacity kW 14.0  14.0  22.4  22.4  28.0  28.0  33.5  33.5 
Power kW 0.30  0.35  0.48  0.55  0.50  0.58  0.68  0.78 
Nominal Current A 1.4 1.61  2.2 2.53  2.3 2.65  1.43  1.64 
Heating Capacity kW 13.7  13.7  21.9  21.9  24.5  24.5  26.8  26.8 
Power kW 0.30  0.35  0.48  0.55  0.50  0.58  0.68  0.78 
Nominal Current A 1.4 1.61  2.2 2.53  2.3 2.65  1.43  1.64 
Sound Pressure Level dB(A) 42 42 44 44 47 47 56 56
(overall a scale)
Dimensions H×W×D mm 370×1,320×800 370×1,320×800 486×1,270×1,069 486×1,270×1,069 486×1,270×1,069 486×1,270×1,069 486×1,270×1,069 486×1,270×1,069
Net Weight kg 63 63 110 110 110 110 110 110
Refrigerant R410A
Air Flow Rate m3/min 18 18 28 28 35 35 50 50
External Pressure Pa 200 200 220 220 220 220 220 220
Piping Liquid mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ12.7 Φ12.7
Gas mm Φ15.88 Φ15.88 Φ19.05 Φ19.05 Φ22.2 Φ22.2 Φ25.4 Φ25.4
Condensate Drain VP25, Outer Diameter: Φ32mm
Temperature range of fresh air drawn Cooling: 20.0°C~43.0°C, Heating: -7.0°C~15.0°C

Model RPI-16.0KFNQL RPI-16.0KFNQH RPI-20.0KFNQL RPI-20.0KFNQH RPI-20.0KFNQLF RPI-20.0KFNQHF


Unit Power Supply AC 3Φ, AC 3, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ, AC 3Φ,
[380-415V/ [380V/ [380-415V/ [380V/ [380-415V/ [380V/ [380-415V/ [380V/ [380-415V/ [380V/ [380-415V/ [380V/
50Hz] 60Hz] 50Hz] 60Hz] 50Hz] 60Hz] 50Hz] 60Hz] 50Hz] 60Hz] 50Hz] 60Hz]
Connectable Outdoor Unit RAS-16FSNS/P RAS-20FSNS/P
Cooling Capacity kW 45.0  45.0  45.0  45.0  56.0  56.0  56.0  56.0  56.0  56.0  56.0  56.0 
Power kW 0.72  0.83  1.06  1.22  1.06  1.22  1.39  1.6 1.39  1.6 1.72  1.98 
Nominal Current A 1.8 2.07  2.2 2.53  2.22  2.55  3.14  3.61  3 3.45  3.9 4.45 
Heating Capacity kW 36.0  36.0  36.0  36.0  44.8  44.8  44.8  44.8  44.8  44.8  44.8  44.8 
Power kW 0.72  0.83  1.06  1.22  1.06  1.22  1.39  1.6 1.39  1.6 1.72  1.98 

INDOOR UNITS & VENTILATION


Nominal Current A 1.8 2.07  2.2 2.53  2.22  2.55  3.14  3.61  3 3.45  3.9 4.45 
Sound Pressure Level dB(A) 58  58 62 62 61 61 65 65 63 63 67 67
(overall a scale)
Dimensions H×W×D mm 635×1,950×805 635×1,950×805 735×1,950×805 735×1,950×805 735×1,950×805 735×1,950×805
Net Weight kg 196  196  196 196  222  222 222 222 222  222 222 222
Refrigerant R410A
Air Flow Rate m3/min 67  67  67  67  83  83  83  83  100  100  100  100 
External Pressure Pa 200  200  300  300  200  200  300  300  200  200  300  300 
Piping Liquid mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Gas mm Φ25.4 Φ25.4 Φ25.4 Φ25.4 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Φ28.6
Condensate Drain RC1 (Internal Screw)
Temperature range of fresh air drawn Cooling: 20.0°C~43.0°C, Heating: -7.0°C~15.0°C
Notes:
1. C
 ooling capacity and heating capacity test in the following conditions:
Cooling conditions: 33.0°CDB, 28.0°CWB, pipeline length 7.5 metre, pipe height difference 0 metre
Heating conditions: 0°CDB, -2.9°CWB, pipeline length 7.5 metre, pipe height difference 0 metre (heating is the data without defrosting)
2. N
 oise test conditions are as follows:
At a distance of 1.5 metre from the unit surface
The above parameters are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be counted at the scene.
3. A
 n air filter with dust removal efficiency of 50% or more needs to be installed at the air inlet.
4. W
 hen the field duct resistance is small and the fan speed is too high, the unit will appear the phenomena of abnormal shutdown, fault, water spray etc., and the
duct pipe should be insulated to prevent generating dew.
5. A
 ir processor can only be used for processing fresh air, indoor air conditioning load processing need to use other air conditioners.
6. Fresh air processing unit should be connected with SET FREE Σ Heat Pump Type outdoor unit.
When fresh air processing unit and other indoor units air all connected to the same SET-FREE outdoor unit, Its equivalent cooling capacity is calculated by the
following criteria:
Type_5HP class: 21.0kW; 8HP class: 33.3kW; 10HP class: 42.0kW
7. Refer
 to capacity restrains shown on Table below for indoor unit capacity connectable to outdoor unit.
System All Fresh Air Unit System Mixed System
(Only All Fresh Air Unit) (All Fresh Air Unit and Other Indoor Unit)
Range of Combination Capacity 80 to 100% i) 80 to 100%
and
ii) Total Capacity of All Fresh Air: 30%

8. W
 hen outdoor temperature is below 20.0°C in cooling operation, the system will be automatically converted to ventilation operation.
When outdoor temperature is higher than 15.0°C in heating operation, it will be automatically converted to ventilation operation. When lower than -7.0°C, the
fresh air processing unit will stop running.

81 82

059-082_SMZ_HP_IDU_0614.indd 82 2019/06/14 14:51


083-112_SMZ_HP_CTR_0614.indd 83 2019/06/14 14:47

Controllers

SET FREE Σ – FSNP & FSNS SERIES


83 Individual controllers
85 Line up overview
87 PC-ARF1
91 PC-AR
PC-ARH1
92 PC-AWR
RECEIVER KIT

CONTROLLERS
93 Centralized controllers
94 Line up overview
95 CENTRAL STATION mini
97 CENTRAL STATION EZ
99 CENTRAL STATION EX
103 CENTRAL STATION NT
105 CENTRAL STATION PSC-A64S
106 CENTRALIZED ON/OFF CONTROLLER PSC-A16RS

107 H-LINK

109 Others
109 BMS ADAPTER For BACnet® HC-A64BNP1
BMS ADAPTER for LONWORKS® HARC70-PE1
110 BMS ADAPTER for LONWORKS® HARC-BXE
111 7 DAY TIMER PSC-A1T
112 3P CONNECTOR CABLE PCC-1A
REMOTE SENSOR THM-R2A
REMOTE CONTROL CABLE PRC-5K, 10K, 15K

83 84

083-112_SMZ_HP_CTR_0614.indd 84 2019/06/14 14:47



LINE UP OVERVIEW
INDIVIDUAL CONTROLLERS

ADVANCED WIRED WIRED REMOTE SIMPLIFIED WIRED REMOTE ADVANCED WIRELESS


REMOTE CONTROLLER CONTROLLER CONTROLLER REMOTE CONTROLLER

PC-ARF1 PC-AR PC-ARH1 PC-AWR


Connection Capacity RC Groups 1 1 1 -
Indoor units (*1) 16 16 16 -
Setting Temperature Setting Rate (*2) 0.5°C/1.0°C 1.0°C 0.5°C/1.0°C 0.5°C/1.0°C
Indoor Fan Speed (*2) (*3) 3/4/6 taps 3 taps 3/4/6 taps 3/4/6 taps
Louver Direction (*2)
Individual Louver Setting (*2) - - -
Remote Control Primary-Secondary Setting -
Function Automatic Restart with Eco-operation - - -
Selection
Automatic Reset Temperature (Cooling) -
Temperature Indication (*4) - - -
Filter Sign Filter Sign - -
Filter Sign Reset -
Louver Open/Close - -
Room Name Setting - - -
Alarm Sign -
Identifying indoor units side-by-side - - -
Screen Screen Adjustment - - -
Language - - -
Temperature Unit_°C -
Adjusting Brightness of Run Indicator - - -
Check Menu Sensor Condition Check - -
Model Display (*2) - - -
Indoor/Outdoor PCB Check - - -
Alarm History Display - - -
Operation Filter Sign - -
Lock/Set
Lower Limit for Cooling Operation -
Upper Limit for Heating Operation -
Built-in Timer (On/Off) -
Adjusting Date/Time Setting - - -
Automatic OFF timer setting - -
Schedule Weekly Schedule (*5) - -
Settable Timer Operation Times (Per Day) 5 - - -
Holiday Setting - - -
Schedule On/Off - - -
Management Operation Lock/Set - - -
Outdoor Unit Peak cut control - - -
capacity control
moderate control - - -
Indoor Unit Indoor Unit Address - - -
Rotation Control
Indoor Air Temperature difference - - -
Automatic Fan Operation - - -
MENU ODU silent mode - - -
Quick Function - - -
Comfort setting - - -
Saving/ODU Noise Reduction Schedule - - -
Daylight Saving Time - - -
Power Consumption visualization - - -

(*1) All 16 indoor units need to be connected with transition wire.


(*2) A
 vailability depends on the indoor unit type connected to the each individual controllers. Please consult your distributors for more details.
(*3) 6 taps is available for Ducted indoor unit, compact type, RPIZ-HNDTSQ only.
(*4) I ndicated temperature can be selected from two options, the thermistor in the indoor unit or in the individual controller.
(*5) Available if using together with the 7‑day timer(PSC‑A1T).

083-112_SMZ_HP_CTR_0614.indd 85 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
CONTROLLERS

85 86

083-112_SMZ_HP_CTR_0614.indd 86 2019/06/14 14:47


ADVANCED WIRED REMOTE CONTROLLER

PC-ARF1

Room Name Indicator Filter Sign Indicator Fltr SPECIFICATIONS


Swing Louver Indicator
Operation Lock Indicator
Fan Speed Indicator
Outer Dimensions (H×W×D)
Schedule Timer Indicator (mm) 120.0×120.0×17.9
Ventilation Indicator

Operation Mode
Indicator Setting
Temperature
Indicator
Operation Guide
Indicator

Run Indicator Menu Switch

Run/Stop Switch

Directional Key Enter Key Back/Help ECO


Switch Switch

EXAMPLE OF SYSTEM CONFIGURATION


2 IDU Connection Up to 16 IDU Connection

2 RC
control is ........
available

Up to 16 IDU

H-LINK
Primary RC Secondary RC Transition wiring is necessary Remote Control Cable

FUNCTIONS
Setting Run/Stop Screen Screen Adjustment Management Operation Lock/Set
Operation Mode Language Main/Sub Control
Auto Mode Setting Temperature Unit_°C Built-in-Timer (On/Off)
Temperature Setting Adjusting Brightness of Run Indicator Adjusting Date/Time Setting
Temperature Setting Rate_0.5°C /1.0°C Check Menu Sensor Condition Check Thermometer Indication
Fan Speed_3/4/6 Taps Sensor Data Check Power- With Motion Sensor Kit
Saving
Louver Direction Model Display ODU Capacity Control
• Peak Shaving Control
Individual Louver Setting Indoor/Outdoor PCB Check
• Propoer Limit Control
Remote Control Primary-Secondary Setting Self Checking
Indoor Unit Rotation Control
In Use of Ventilation Alarm History Display
Total-Heat- Automatic Fan Operation
Total Heal Exchanger Setting Test Run Test Run
Exchanger Auto Recovery of Temperature
Function Selection
Function Automatic Restart with Upper Limit for Heating Operation
(Optional Function Setting)
Selection Eco-operation
Thermistor Selection Lower Limit for Cooling Operation
Automatic Reset Temperature
(Cooling/Heating) Input/Output Setting Power Consumption Visualization

Temperature Indication Indoor Unit Address Change Schedule Weekly Schedule

Service Filter Sign Indoor Unit Address Checking Operation Settable Timer Operation Times (per day): 5

Filter Sign Reset Indoor Unit Address Initialization Holiday Setting

Louver Open/Close Input-Output Setting Initialization Schedule On/Off

Room Name Setting Compressor Pre-Heat Control Cancellation ODU Noise Reduction Schedule

Alarm Sign Contact Information Registration

083-112_SMZ_HP_CTR_0614.indd 87 2019/06/14 14:47


COMFORT

SET FREE Σ – FSNP & FSNS SERIES


GentleCool Control
Set your comfortable temperature not only for “Room” but also for “Air” in cooling operation.
To make your room reach to the desired temperature faster, the discharged air from the indoor unit
can be sometimes much cooler, causing discomfort at the beginning of operation.
Now, you can choose “discharge air temperature = your own comfort level”, as you like, by our
advanced wired remote controller PC-ARF1.
You can be In comfort and avoid cold draft from the moment when cooling operation starts, while the
room gently cools down. "Comfort Setting" Control Cool Air in PC-ARFPE1

Potential Discomfort GentleCool No Cold Draft

>8.0°C >12.0°C >14.0°C >16.0°C


→ COLD DRAFT

GentleCool: OFF GentleCool: LOW GentleCool: MED GentleCool: HIGH

CONTROLLERS
Away Function

Off set the temperature when the space is not occupied


reducing the power consumption
Optional accesories required

Room card A Room card B Room card C Room card D


OUT IN OUT IN

30.0°C 23.0°C 27.0°C 23.0°C

A Returning to set
30.0°C
temperature when
C room key inserted
27.0°C

B D
23.0°C

Room card Room card Room card


in off off

87 88

083-112_SMZ_HP_CTR_0614.indd 88 2019/06/14 14:47


ADVANCED WIRED REMOTE CONTROLLER

PC-ARF1

POWER-SAVING FUNCTION

With Motion Sensor


Perceives the amount of human activity and undertakes automatic saving.

Standard operation for a room Moderate operation for a room More moderate operation if It is also possible to stop
with a lot of human movement. with little human movement. people are absent for a certain the operation of the unit by
period of time. applying a particular setting if
people remain absent for more
than 30 minutes.

Outdoor Unit Capacity Control Two Options


(1) Peak-shaving control:
set the limit on the power
Power Consumption

without Power Saving Setting Power Saving Set Value


consumption range It can be selected from
100%, 90%, 80%, 70%,
60%, 50%,and 40%
Maximum Capacity Operation of reference power
in Power Saving Set Value Range consumption.

Morning Daytime Night

(2) Proper limit control:


keep the power
Power Consumption

consumption within without Moderate Control Setting


proper limit (40-90%)
Moderate Control Setting

Operation Time

Indoor Unit Rotation Control Order of Fan Operation 1

Switch multiple indoor Fan Operation Cooling Operation


units operation to “FAN” Indoor Unit 1 The indoor unit fan
Order of Fan Operation 2 operation is
mode, one by one, in order. performed in rotation by
Cooling Operation Fan Operation Cooling Operation indoor unit address no.
Indoor Unit 2
Order of Fan Operation 3

Cooling Operation Fan Operation


Indoor Unit 3

Time

Automatic fan operation 30 Minutes 30 Minutes

Alternate between SAV:LOW


Cooling Operation Fan Operation Cooling Operation Fan Operation
20 Minutes 10 Minutes 20 Minutes 10 Minutes
“heating/cooling” and
“FAN” at a certain interval. Cooling Operation Fan Operation Cooling Operation Fan Operation
SAV:MED
17 Minutes 13 Minutes 17 Minutes 13 Minutes

SAV:HIGH Cooling Operation Fan Operation Cooling Operation Fan Operation


15 Minutes 15 Minutes 15 Minutes 15 Minutes

Time

083-112_SMZ_HP_CTR_0614.indd 89 2019/06/14 14:47


SET FREE Σ – FSNP & FSNS SERIES
Auto-Recovery of Temperature Temperature Range Setting
Reducing excessive energy consumption thanks to automatic Prevent wasteful power consumption due to excessive use of cooling/
temperature reset. heating mode.
[Cooling Mode] [Cooling Mode]
Temperature Temperature
19.0°C/66.0°F 30.0°C/86.0°F
Set-Point
Normal
28.0°C/82.0°F

Back to 25.0°C/77.0°F 30.0°C/86.0°F


Lower to
28.0°C/82.0°F
19.0°C/66.0°F
Automatically ON

19.0°C/66.0°F Lower Limit


≥25.0°C/77.0°F
Can not go lower Available set range

Time
After a certain time passes, the changed temperature returns to the set
point. The time can be selected from four options (15‑30‑60‑90 mins).

Weekly Schedule Power consumption visualization


Seven‑day timer with multiple set‑points (up to 5 actions per day): Check power consumption in the unit of day, week, and year.
No need to worry about controlling the air conditioner each time, ODU compressor only
each day.

CONTROLLERS
In Case of Restaurant in
Cooling Mode

ADAPTABILITY

Improved main-sub RC control Temperature Setting Rate


By one main RC, you can Setting available in
control the multiple IDUs 0.5°C/1.0°C or 1.0°F.
which are controlled by ........

sub RC.
* Operation Mode
* Setting Temperature
Main RC Sub RC Sub RC Sub RC

Alarm code check Thermometer function


Contact address shown in the Current temperature can be
same display. displayed anytime, without
being in maintenance mode.
* Thermometer can be chosen out of 4
sensors (Air inlet, Air outlet, Remote
controller and Remote Sensor (THM-
R2A))

ODU silent mode Help Menu


Set in the weekly schedule by Access when in trouble. Screen
5 times. guide, Operation Manuals,
Troubleshooting Q&A listed.

89 90

083-112_SMZ_HP_CTR_0614.indd 90 2019/06/14 14:48


WIRED REMOTE CONTROLLER

PC-AR
Swing Louver Indicator
Defrost Indicator
ON/OFF Timer (Timer Operation) Indicator SPECIFICATIONS
TEMP.(Set Temperature) Indicator
CENTRAL (Central Control) Indicator Alarm Code Indicator
Outer Dimensions (H×W×D)
"NO FUNCTION" Indicator
Fan Speed Indicator
Operation Lock Indicator (mm) 120.0×120.0×17.0
Ventilation Indicator
Automatic Control Indicator

Operation Mode Indicator


Automatic Cooling/Heating
Operation Indicator "FILTER" Indicator
"ABNML" (ALARM) Indicator
Run Indicator (Red Lamp)

RUN/STOP Switch TEMP (Temperature Setting)


Switch
Open the cover by pulling MODE FAN SPEED ON/OFF TIMER RESET
in the direction of the arrow RESET (Filter Reset) Switch
VENT LOUVER CHECK
Mode (Operation Mode TIME Check Switch
Selection) Switch
Fan Speed Selection Switch

Elevating Grille Operation Switch


ON/OFF TIMER Switch
VENTI (Ventilator Operation) Switch
TIME (Time Setting) Switch
SWING LOUVER (Swing Louver Operation) Switch

FUNCTIONS
Setting Run/Stop Check Menu Sensor Condition Check Management Operation Lock-Set
Operation Mode Sensor Data Check Lower Limit for Cooling Operation
Auto Mode Setting Test Run Test Run Upper Limit for Heating Operation
Temperature Setting Function Selection Built-in Timer (On/Off)
Temperature Setting Rate_1.0°C (Optional Function Setting) Schedule Weekly Schedule (+PSC-A1T)
Fan Speed_3 Taps Thermistor Selection
Louver Direction Input-Output Setting
Remote Control Primary-Secondary Setting Indoor Unit Address Change
Automatic Reset Temperature Indoor Unit Address Checking Operation
(Cooling/Heating) Indoor Unit Address Initialization
Service Filter Sign Input-Output Setting Initialization
Filter Sign Reset Compressor Pre-Heat Control Cancellation
Elevating Grille
Louver Open/Close
Alarm Sign

SIMPLIFIED WIRED REMOTE CONTROLLER



PC-ARH1
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×70.0×17.0

FUNCTIONS

TEMP (Temperature Setting) Setting Run/Stop


Run Indicator (Red)
ON/OFF Switch Switch Operation Mode
Auto Mode Setting
Temperature Setting
Operation Mode Switch Swing Louver
(Swing Louver Operation) Temperature setting rate_0.5°C /1.0°C
: FAN : DRY
: COOL : AUTO Switch Back-light screen
: HEAT
Fan Speed_3/4 taps
By repeatedly pressing
Fan Speed Switch
the button, the setting Louver Direction
By repeatedly pressing the button,
will change sequentially.
the fan speed setting will change
sequentially.

083-112_SMZ_HP_CTR_0614.indd 91 2019/06/14 14:48


WIRELESS REMOTE CONTROLLER

PC-AWR
Transmitter SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 140.0×55.0×16.8

SET FREE Σ – FSNP & FSNS SERIES


Transmitting Indication
LCD (Liquid Crystal Display)
FUNCTIONS

Mode Selection Switch Setting Run/Stop


Fan Speed Switch
On Switch Operation Mode
Reset Switch
Auto Mode Setting
Off Switch
Temperature Setting
Louver Angle Switch Temperature Setting Rate_0.5°C/1.0°C
Timer Switches Temp. Switch Fan Speed_3/4/6 Taps

Filter Sign Reset Switch Louver Direction


Service Filter Sign Reset
Identifying indoor units side-by-side
Temperature Unit_°C
Schedule Built-in Timer (On/Off)

EXAMPLE OF SYSTEM 1 IDU connection

CONFIGURATION

H-LINK
Remote Control Cable

CONTROLLERS
CONTROLLER SYSTEMS – INDIVIDUAL

RECEIVER KIT
FOR WIRELESS REMOTE
CONTROLLER (PC-AWR)
PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1

Dimensions Height 36.0 35.0 27.5 25.0 23.0 28.0


(mm)
Width 203.0 207.4 135.4 102.0 102.0 120.0

Depth 203.0 207.4 135.4 115.0 115.0 90.0

Model PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1

For indoor 4-Way 4-Way 2-Way 1-Way Ceiling Ducted Floor Floor Floor/Ceiling Wall
unit model Cassette Cassette Cassette Cassette Suspended Exposed Concealed Convertible Mounted
Compact


For more information about options and accessories,
please consult your Hitachi Cooling & Heating channel
partner.

91 92

083-112_SMZ_HP_CTR_0614.indd 92 2019/06/14 14:48


083-112_SMZ_HP_CTR_0614.indd 93 2019/06/14 14:48

LINE UP OVERVIEW
CENTRALIZED CONTROLLERS

CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRALIZED
mini EZ EX NT ON/OFF CONTROLLER

SET FREE Σ – FSNP & FSNS SERIES


PSC-A32MN PSC-A64GT PSC-A128EX PSC-A128WEB3 PSC-A64S PSC-A16RS

Capacity Total Connection capacity RC group 32 64 2,560 (*1) - 64 16


comparison
Group 4 64 2,048 (*1) 128 64 -

Block 2/4/8/16 4 512 (*2) 64 4 -

Area - - 512 (*2) - - -

Indoor unit 160 160 2,560 (*1) 160 160 160

Outdoor unit 64 64 1,024 (*1) 64 64 -

Building scale Small Medium Large Medium Large Medium Medium

Operation Touch screen Touch screen Touch screen PC or touch-panel-PC Button Button
supplied locally
Display Operation panel size options 4 2 7 2 - -

Layout - - • - - -

List options - - 3 - - -

Operation unit All together • • • • • •


By layout - - • - - -

By area - - • - - -

By block • • • • • -

By group - - • • - -

By RC group • • - - • •
By indoor unit - - • • - -

CONTROLLERS
Control Function Main 5 functions (*5) • • • • • - (*6)

Individual controller lock • △ (*3) • • • -

Filter sign reset • • • • • -

Outdoor unit capacity control △ (*4) - • - - -

Outdoor unit noise control - - • - - -

Monitor Function Main 5 functions (*5) • • • • • -

Individual controller lock • • • • • -

Alarm status & code • • • • • - (*7)

Filter sign • • • • • -

Air inlet temperature of indoor unit • • • • - -

Air inlet temperature of outdoor unit • • • • - -

Schedule Function Weekly • • • • - (*8) - (*8)

Setting times per day 10 10 16 16 3 (*8) 3 (*8)

Special day setting - - 5 • - -

Annual/Summer/Winter schedule - - • • - -

Other function Alarm history (records number) 100 100 10,000 500 - -

External in/output history - - 1,000 - - -

Management report visualization • • • - - -

Data output by external media - - SD card, USB flash - - -


device

(*1) One external adapter can control (128 remote controller groups/128 groups/32 blocks), and Central Station EX can connect up to 15 adapters.
(*2) No restriction on the number of H-LINK
(*3) Individual Function Control in Each Remote Controller is not applicable
(*4) Applicable by Schedule function or External Signal input
(*5) Main 5 functions mean 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control
(*6) Only Run/Stop is available
(*7) Alarm Code cannot be displayed, but Operation indicator keeps flashing in red to inform abnormal condition
(*8) Available with 7-day timer (PSC-A1T)

93 94

083-112_SMZ_HP_CTR_0614.indd 94 2019/06/14 14:48


CENTRAL STATION

mini
PSC-A32MN
FOR SMALL-SCALE BUILDINGS

22 52.7 CAPACITY
RC group 32
Group 32
Block 4 Patterns (2/4/8/16)
Indoor Unit 160

120mm Outdoor Unit 64


Building Scale Small

SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Lateral View (mm) Electrical Power Consumption 20W (Max.)
140mm Communication Unit Units of Adopting for H-LINK
Communication Line Non-polar 2-wire
Communication Speed 9,600bps
Wiring Length 1,000m (Total Length)
Display 5.0-inch Wide Color LCD (Full Dot)
Display Control Touch Panel

FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
• RC Operation Prohibited Setting
• Accumulated Operating Time
Most compact in our touch panel centralized • Operation Mode • Setting Fan Speed
controller. Its down-to-detail control • Setting Louver • Filter Sign • Alarm Code”

functionalities, such as Weekly Scheduling, Control Function • Run/Stop* • Fan Speed


• Operation Mode • Louver
Accumulated Work Hours, etc., help you save • Temperature Setting
energy. Up to 32 remote-controlled groups and • RC Operation Prohibited
• Filter Sign Reset
up to 160 indoor units can be connected to the *: “All Groups Run/Stop” command signal exception function for selected groups is
single air-conditioning system. available by “Exception of Run/Stop Operation.” function.

EXAMPLE OF SYSTEM CONFIGURATION

CS mini

Total 32
RC Groups
H-LINK
Remote Control Cable

083-112_SMZ_HP_CTR_0614.indd 95 2019/06/14 14:48


(5-inch) Touch Panel Operation Schedule

SET FREE Σ – FSNP & FSNS SERIES


Easy to check the operation status using either of two monitoring Up to 10 actions/day per RC group
screens (all groups or four pattern blocks [2/4/8/16]) can be set as available as auto For example :
switch‑off timer School

In case of classroom
mini
in cooling mode
9:00 ~ 10:00 27 °C Class: on
10:00 ~ 11:00 27 °C Class: on
11:00 ~ 12:00 - °C No class: off
12:00 ~ 13:00 25 °C LUNCH TIME
13:00 ~ 14:00 - °C No class: off
14:00 ~ 15:00 27 °C Class: on
15:00 ~ 16:00 - °C No class: off
16:00 ~ 17:00 27 °C Class: on
17:00 ~ - °C No class: off

[Monitor (Block)]

RC Group Function Control Accumulated Operation-Time Visualization


‑each operational item blocking‑prevent incorrect operation Support energy-saving management

CONTROLLERS
ON/OFF, "operation mode," "fan speed," "swing louver direction," "setting
temperature," and "prohibition of remote control operation for individual items (run/
stop, operation mode, fan speed, wind direction, setting temperature)"

Energy Saving
Outdoor unit power consumption control by schedule or external signals. Setting temperature range.

[Capacity Control of ODU] [Temperature Limitation for Each Remote Controller]

95 96

083-112_SMZ_HP_CTR_0614.indd 96 2019/06/14 14:48


CENTRAL STATION

EZ
PSC-A64GT
FOR MEDIUM-SCALE BUILDINGS

80 CAPACITY
25 55
RC group 64
Group 64
Block 4 Patterns
Indoor Unit 160
170mm Outdoor Unit 64
Building Scale Small - Medium

SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Lateral View (mm)
Electrical Power Consumption 30W (Max.)
250mm
Communication Unit Units of Adopting for H-LINK
Communication Line Non-polar 2-wire
Communication Speed 9,600bps
Wiring Length 1,000m (Total Length)
Display 8.5-inch Wide Color LCD (Full Dot)
Display Control Touch Panel

FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
Easy control with 8.5 inch color touch panel, • RC Operation Prohibited Setting
• Accumulated Operating Time
Its down-to-detail control functionalities, • Operation Mode • Setting Fan Speed
such as Weekly Scheduling, Accumulated • Setting Louver • Filter Sign • Alarm Code
Control Function • Run/Stop* • Fan Speed
Work Hours, etc., help you save energy. Up to • Operation Mode • Louver
64 remote-controlled groups and up to 160 • Temperature Setting
• RC Operation Prohibited
indoor units can be connected to the single air- • Filter Sign Reset
conditioning system. *: “All Groups Run/Stop” command signal exception function for selected groups is
available by “Exception of Run/Stop Operation.” function.

EXAMPLE OF SYSTEM CONFIGURATION

CS EZ

Total 64
RC Groups
H-LINK
Remote Control Cable

083-112_SMZ_HP_CTR_0614.indd 97 2019/06/14 14:48


(8.5-inch) Touch Panel Operation

SET FREE Σ – FSNP & FSNS SERIES


A total of 64 remote controller groups (4 blocks)(64 outdoor units/160 indoor units) can be controlled
Easy to check the operation status using either of two monitoring screens (all groups or blocks)
The panel for the block is bigger than for the CS MINI; you can check Mode, Fan Speed, Louver, Temperature, Inlet and Ambient Temperature.

[Monitor 1 (all groups)] [Monitor 2 (block)]

ACCUMULATED OPERATION-TIME VISUALIZATION


Supports Energy-Saving Management

CONTROLLERS
Alarm Information
Red color indication: immediate display of malfunction location and cause.

Schedule
Up to 10 actions/day per RC groups can be set as available as auto switch‑off timer.

[Weekly Schedule] [Holiday Setting]

97 98

083-112_SMZ_HP_CTR_0614.indd 98 2019/06/14 14:48


CENTRAL STATION

EX
PSC-A128EX
FOR LARGE-SCALE BUILDINGS

32.5 27.8 CAPACITY


H-LINK 16
Remote Controller group 2,560 (*1)
Group 2,048 (*1)
Block 512 (*2)
227.2mm
Area 512 (*2)
Indoor unit 2,560 (*1)
Outdoor unit 1,024 (*1)
Building scale Large

(*1) One external adapter can control [160 RC groups / 128 groups / 160 IDUs / 64
372mm ODUs / Each layout], and Central Station EX can connect up to 15 adapters.
Lateral View (mm)
(*2) No restriction on the number of H-LINK

SPECIFICATIONS
SD Rated power supply 100~240VAC ±10% (50/60Hz)
Electrical power consumption 50W (Max.)

Energy Calculation Software* Communication unit Units of Adopting for H-LINK

Extension Adapter PSC-AS01EXC Communication line Nonpolar Two Wires


PSC-AD128EX *Required only for calculating electricity Communication speed 9,600bps
Wiring length 1,000m (Total Length)
Display 12.1 inch TFT color liquid crystal display
Display control Touch Panel
For large scale buildings such as hotels, educational
facilities, or hospitals, our Central Station EX features
a highly intuitive and functional 12.1-inch wide, wall-
mountable, colorful LCD screen. Control up to 2,560
indoor units with our proprietary H-LINK system with
15 Extension Adapters (PSC-AD128EX)

FUNCTIONS
Operation All together Schedule Each of the following setting is available in 3 External Energy saving
unit Each area function different [annual] [summer][winter] category input / • Run/Stop
Each block → Weekly schedule output • RC prohibition
Each group → Up to 16 actions can be set per day • Temperature shift
Each RC group → Exception day setting: 5 different types (For Cool/Dry mode: +1.0°C~+9.0°C)
Control On/Off → Holiday setting (For Heat mode: -1.0°C~-9.0°C)
function Mode • Mode shift
Set temperature Setting items in schedule is as below; (Mode shifted to Fan when in Cool/Dry
Fan speed • On/Off mode, and shifted to Stop in Heat mode)
Louver • Operation mode • Capacity control on outdoor units
RC prohibition • Setting temperature • Lower noise control for outdoor units
Filter sign reset • Louver
Function selection for indoor units (*1) • Fan speed Control/Monitor
Function selection for outdoor units (*2) • RC operation prohibition → Controlled items:
Capacity control for outdoor units (*2) • Capacity control for outdoor units • Run/Stop
Lower noise control for outdoor units (*2) • Lower noise control for outdoor units • Mode (Cool/Heat)
History Alarm history: 10,000 records → Monitored items:
Monitor On/Off
External In/Output history: 1,000 records • Run/Stop
function Mode
Pulse input history: 6 months • Mode (Cool/Heat)
Set temperature
• Alarm state
Air intake temperature Management Each of the following data of up to 2 years
RC sensor temperature (*3) report can be shown:
Others
Air intake temperature of outdoor unit visualization • Accumulated operation time (min.)
• Power consumption signal input
Fan Speed • Accumulated thermo-ON time (min.)
• Emergency stop
Louver • Average air intake temp temperature of
RC prohibition indoor unit (*1) Some indoor units may not fully support all functions.
Thermo-ON information • Average air intake temperature of outdoor (*2) It is available for applicable outdoor units only.
Filter sign/Auto cleaning fault unit (*3) There is a case that it cannot be shown in the screen,
Alarm status/Alarm codes • Average setting temperature depending on the remote controller setting.
• Average RC sensor temperature

083-112_SMZ_HP_CTR_0614.indd 99 2019/06/14 14:48


EASY TO READ, EASY TO USE Flick and swipe to turn pages

SET FREE Σ – FSNP & FSNS SERIES


The stand-alone Central Station EX uses a touch screen,
capacitive LCD panel.

Better display resolution (1,280×800)


Larger screen (12.1 inches wide)

BETTER ENERGY SAVING AND QUICKER MANAGEMENT


Management reports can be visualized in various ways,
and data can be acquired using SD memory and USB flash
devices.

Various data such as operation time, The following data can be


settings, and log history can be
displayed up to the previous two
saved to CSV files for better energy
years:

CONTROLLERS
management and quicker service
maintenance.
• Accumulated operation time
SD
(min.)
• Accumulated thermo-ON time
USB
(min.)
• Average air intake temperature of
indoor unit
• Average air intake temperature of
outdoor unit
• Average setting temperature
• Average RC sensor temperature
(It may not be available
depending on RC settings.)

IMPROVED SCHEDULE SETTING Drag to change the schedule


Flick and swipe to see a different screen
Three long-term category settings are now available:
Annual, Summer, and Winter.

Touch and hold the memory axis to


add the memory to the schedule

Schedules can be color coded for


easy confirmation

Touch the + button to see the


detailed schedule

99 100

083-112_SMZ_HP_CTR_0614.indd 100 2019/06/14 14:48


CENTRAL STATION

EX
PSC-A128EX
FOR LARGE-SCALE BUILDINGS

INTUITIVE INTERFACE FOR BETTER MONITORING


Three monitoring styles are available.

1. Panel style
The panel color clearly shows the air conditioner operation mode.

One maximum-sized panel can show the following items with colors
and icons for easy confirmation:
• Room name • Run/stop • Mode • Temperature • Fan speed • Louver
• Air intake temperature (RC sensor temperature or indoor temperature)
• Current status icon

Maximum Minimum
size size

Largest range of sizes (seven)

2. Layout style
Upload your own layout images in multiple formats (BMP, JPEG, PNG)
and easily arrange indoor units by dragging them on the touch panel.

Floor view

System diagram Actual room image

083-112_SMZ_HP_CTR_0614.indd 101 2019/06/14 14:48


SET FREE Σ – FSNP & FSNS SERIES
3. List style
Setting/control information is shown in a list that can be filtered and sorted for easy
confirmation and comparison. In the list display, normal temperature and power
consumption are provided so users can select formats according to their desired
items.

CONTROLLERS
Normal mode Temperature mode Power consumption mode

101 102

083-112_SMZ_HP_CTR_0614.indd 102 2019/06/14 14:48


CENTRAL STATION

NT
PSC-A128WEB3
PC AND TOUCH PANEL: WEB OPERATION

SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0

FUNCTIONS
Total RC group -
Connection
Group 128
Capacity
Block 64
Indoor Unit 160
Outdoor Unit 64
Building Scale Medium Large

FUNCTIONS
Display Locally-Supplied PC or Touch-Panel PC
Display Control Locally-Supplied or Touch-Panel

Total Connection Capacity One connected unit Two or three connected units
OS • Windows 7 Home Premium (32 bit/64 bit) • Windows 7 Home Premium (32 bit/64 bit)
• Windows 7 Professional (32 bit/64 bit) • Windows 7 Professional (32 bit/64 bit)
• Windows 7 Ultimate (32 bit/64 bit) • Windows 7 Ultimate (32 bit/64 bit)
• Windows 8 (32 bit/64 bit) • Windows 8 (32 bit/64 bit)
• Windows 8 Pro (32 bit/64 bit) • Windows 8 Pro (32 bit/64 bit)
CPU Intel® Core™2 Duo 1.8GHz or more Intel® Core™2 Duo 1.8GHz or more
(When it is a specific unit, it should be Intel Atom 1.6GHz or more) (When it is a specific unit, it should be Intel Atom 1.6GHz or more)
Memory 1GB or more 2GB or more
Monitor 1,024×768 pixels (Display around 15 inches) 1,024×768 pixels (Display around 15 inches)
1,366×768 pixels (Wide screen display) 1,366×768 pixels (Wide screen display)
1,280×1024 pixels (Display around 17 to 19 inches) 1,280×1024 pixels (Display around 17 to 19 inches)
Browser • Internet Explorer 8 (32 bit) • Internet Explorer 8 (32 bit)
• Internet Explorer 9 (32 bit) • Internet Explorer 9 (32 bit)
• Internet Explorer 10 (32 bit) • Internet Explorer 10 (32 bit)
• Internet Explorer 11 (32 bit) • Internet Explorer 11 (32 bit)
HDD Available Capacity 10GB or more 10GB or more
Interface IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T) or IEEE 802.11 (a/b/g/n) IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T) or IEEE 802.11 (a/b/g/n)
Required Software JavaTM Runtime Environment Version 6 Update 33 JavaTM Runtime Environment Version 6 Update 33
Remarks
• Use a 2 buttons mouse.
• LAN with wake on LAN function or RS-232C Interface is required for UPS.
• The durable period for a management computer may differ from that of air conditioners.
Discuss the updating procedures in advance.
• The required software is included in this product. No preparation is needed.

EXAMPLE OF SYSTEM CONFIGURATION

CS NT CS NT

Internet or LAN
(Ethernet)
H-LINK
Remote Control Cable
LAN(Ethernet)

083-112_SMZ_HP_CTR_0614.indd 103 2019/06/14 14:48


Easy-to-use design Panel

SET FREE Σ – FSNP & FSNS SERIES


The newly adopted color indication or panel icon will help you recognize each Icon-based monitoring panel.
unit status and manage your air conditioner more efficiently.
Operation On
Mode On (Cool) On (Heat) On (Dry) On (Fan) On (Auto) (in Multiple Alarm Off
Color Setting Mode)

On Light Sea Light Light Blue


Orange Purple Red Grey
(With Color) Blue Green Grey Orange

Off
(Without Lime Green Red Grey
Color)

Icon
Touch the “Icon Guide” and
you can check each icon
description along with the
details.

Filter
The filtering condition

CONTROLLERS
enables you to check the unit
easily and quickly.

Schedule Alarm History


• Weekly setting (up to 16 actions per day) Up to 500 alarms can be
• Summer/Winter seasonal setting recorded. The installer can
• Special days setting. diagnose the trend of problems
in your air conditioner when
necessary.

[Pattern Setting] [Weekly Setting]

[Special Day Setting] [Summer - Winter Seasonal Setting]

103 104

083-112_SMZ_HP_CTR_0614.indd 104 2019/06/14 14:48


CENTRAL STATION

PSC-A64S
FOR SMALL-MEDIUM-SCALE BUILDINGS

SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×120.0×70.5

CAPACITY
RC group 64
120mm Group 64
Block 4 Patterns
Indoor Unit 160
Outdoor Unit 64

FUNCTIONS
Monitor Function • Run/Stop/Abnormality • Setting Temperature
120mm • RC Operation Prohibited Setting
• Accumulated Operating Time
• Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code
If your site has a dedicated building manager, the Control Function • Run/Stop* • Fan Speed
Central Station PSC-A64S is suitable for providing • Operation Mode • Louver
convenient monitoring of indoor climates. It controls • Temperature Setting
• RC Operation Prohibited
up to 160 indoor units and up to 8 sub-controllers • Filter Sign Reset
can be connected via H-LINK. In addition to setting *: “All Groups Run/Stop” command signal exception function for selected groups is
the operation mode and temperature, PSC-A64S also available by “Exception of Run/Stop Operation.” function.

gives you advanced control over air quality and louver


orientation. Should a problem occur, a dedicated
alarm code helps you identify the issue.

083-112_SMZ_HP_CTR_0614.indd 105 2019/06/14 14:48


CENTRALIZED ON/OFF CONTROLLER

PSC-A16RS

SPECIFICATIONS

SET FREE Σ – FSNP & FSNS SERIES


Outer Dimensions (H×W×D)
(mm) 120.0×120.0×68.5

CAPACITY
RC group 16
120mm
Group 64
Block -
Indoor Unit 160
Outdoor Unit -

FUNCTIONS
Monitor Function • Run/Stop
120mm • Alarm Notification
Control Function • Individual Run/Stop
• Simultaneous All Run/Stop
· Only performs operation/stop control per remote
control group.

· By connecting to the H-LINK, up to 16 remote control


groups and 160 indoor units can be controlled.
Up to 8 controllers can be connected to the H-LINK.

· An external input terminal is provided as standard.


External signals enable the following functions:
central operation / stop, emergency stop, central
operation output, central alarm output.

CONTROLLERS
· Can be used in combination with the central station.

*Be sure to use it with a remote control switch. Indoor


units cannot be used without a remote control
switch.

*There are restrictions on remote group registration.


Please contact our sales staff for more information.

105 106

083-112_SMZ_HP_CTR_0614.indd 106 2019/06/14 14:48



H-LINK

WHAT IS H-LINK?
H-LINK is a “Hitachi” original communication system that can be used to control multiple outdoor and indoor units from one control point. Its use
assists installers and service engineers by simplifying commissioning and service maintenance. For building owners and occupants, it provides
outstanding versatility enabling the connection of various types of central control options, enabling better system management. Our proprietary
high-performance communication system enables the connection of control wiring between indoor and outdoor units, and between a centralized
control system and indoor/outdoor units across two or more refrigerant systems.

Basic Wiring

PSC-A32MN

ADVANTAGES RECOMMENDED FACILITIES (EXAMPLE)


1. A multi air conditioner for a building and a package air
conditioner for a store or office. It can be used with a home
Educational institutions such as primary schools where
air conditioner.
installation work cannot be performed on weekdays.
2. T
 here are no restrictions on the delivery route or order for
wiring.
3. J ust connect to a terminal block.  otels where it is preferable to complete installation work
H
(An adapter and a dedicated connector are not necessary.) during late evenings.

Rehabilitation facilities or hospitals where it is necessary


to minimize the burden on users.

DEFINITION OF TERMS IN HITACHI CENTRALIZED CONTROL SYSTEMS


1. CS-Net/Central Station
Outdoor unit
Hitachi original central controller
2. R
 C Group (Remote Controller System Group)
Stands for a number of indoor units (up to 16 units)
Indoor unit
connected using “same remote controller” wiring.
In this group, connected indoor units are all controlled in
the same way.
3. Group
Stands for the multiple “RC groups” that are registered in
the central controller network setting.
3. Group 2. RC Group
4. Block
CS-NET 3. Group
Stands for the multiple “groups” that are registered in the
central controller network setting. 4. Block

083-112_SMZ_HP_CTR_0614.indd 107 2019/06/14 14:48


POINT

Flexible Wiring Routes

(1) If indoor units are located


in one place and the indoor

SET FREE Σ – FSNP & FSNS SERIES


unit to be controlled is in the
room where “concentrated Point!
control” is installed
 verall control is possible by connecting
O
“concentrated control” to the indoor unit.
Delivery distance can be greatly reduced.

PSC-A32MN

(2) If indoor units are located in


two places and any indoor
units of each system are
located close together Point!
 verall control is possible by connecting
O
part of the indoor units of each system.
Delivery distance can be greatly reduced.

PSC-A32MN

CONTROLLERS
(3) If two systems are completely
separated
 verall control is possible by separately
O
connecting the two systems to Point! Point!
“concentrated control.”
It is possible to select a wiring route based
on the wiring distance and the ease of
installation.

PSC-A32MN

(4) If indoor units are located


discretely
 verall control is possible by connecting
O
indoor units. Point! Point! Point!
Installation is possible through indoor
wiring only without outdoor wiring.

PSC-A32MN

107 108

083-112_SMZ_HP_CTR_0614.indd 108 2019/06/14 14:48



HC-A64BNP1
BMS ADAPTER For BACnet®
Control Up To 64 Indoor Units
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0
FUNCTIONS
Corresponding ANSI/ASHRAE Standard 135-2004
BACnet® BACnet®
Standard
EXAMPLE OF SYSTEM CONFIGURATION Control Item at • Run Stop (Setting)
Upper System • Operation Mode (Setting)
H-LINK • Fan Speed Level (Setting)
Remote Control Cable • Indoor Temperature (Setting)
BACnet ® • Prohibiting RC Operation (Setting)
• Filter Sign Reset
Monitoring Item • Run Stop (State)
Field-supplied
at Upper System • Operation Mode (State)
• Fan Speed Level (State)
Fire • Indoor Temperature (State)
Lighting alarm Lift Ventilation
• Prohibiting RC Operation (State)
• Filter Sign
Central
• Indoor Air Intake Temperature
Controller
• Alarm Signal
• Alarm Code
• Communication State

BACnet ®

HC-A64BNP1


HARC70-PE1
BMS ADAPTER for LONWORKS®
Bigger Connection Capacity (Up to 128 Indoor Units)

SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0

FUNCTIONS
Connection Connection by SNVT
Method to Upper (Standard Network Variable Type)
EXAMPLE OF SYSTEM CONFIGURATION System to LONWORKS® Network
H-LINK Quantity of 8 Remote Control Groups
Remote Control Cable Connection (Max. 128 indoor Units)
LONWORKS® Control Item in • On/Off Order (nviOnOff_ng)
Upper System • Operation Mode Setting (nviMode_ng)
Field-supplied (ng: 0~7) • Temperature Setting (nviSetPoint_ng)
• All On/Off Order (nvi All OnOff)
Monitoring Item • On/Off State & Alarm (nvoOnOff_ng)
Fire in Upper System • Operation Mode State (nvoMode_ng)
Lighting alarm Lift Ventilation
(ng: 0~7) • Temperature Setting (nvoSetPoint_ng)
• Individual Thermostat State (nvoThermo_ng)
• The number of maximum connectable refrigerant systems is
8 (0 to 7). The available setting range of refrigerant system
number and indoor unit addresses is 0 to 15.

LONWORKS®

HARC70-PE1

083-112_SMZ_HP_CTR_0614.indd 109 2019/06/14 14:48



HARC-BXE
BMS ADAPTER for LONWORKS®
Connect to Multiple H-LINK with H-LINK Transmission Terminal to 8 PCB
SPECIFICATIONS
Outer Dimensions (H×W×D)

SET FREE Σ – FSNP & FSNS SERIES


(mm) 285.0×240.0×128.5

EXAMPLE OF SYSTEM CONFIGURATION


H-LINK
Remote Control Cable
LONWORKS®

Field-supplied

Fire
Lighting alarm Lift Ventilation

Central
Controller

LONWORKS®

HARC-BXE

CONTROLLERS
FUNCTIONS
Standard HARC-BXE

Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 64 Indoor Units (8 Indoor Units per 1 PCB)
Control Item in Upper System (n: 0~7) • On/Off Order (nviOnOff_n) • Temperature Setting (nviSetPoint_n) • Operation Mode Setting (nviMode_n)
• All On/Off Order(nviAllOnOff)
Monitoring Item in Upper System (n: 0~7) • On/Off State & Alarm (nvoOnOff_n) • Temperature Setting (nvoSetPoint_n)
• Operation Mode State (nvoMode_n) • Individual Thermostat State (nvoThermo_n)

Option A HARC-BXE (A)

Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 64 Indoor Units (8 Indoor Units per 1 PCB)
Control Item at Upper System (n: 0~7) • On/Off Order (nviOnOff_n) • Temperature Setting (nviSetPoint_n) • Fan Speed Setting (nviFanSpeed_n)
• Operation Mode Setting (nviMode_n) • All On/Off Order (nviAllOnOff)
• R.C. Sw Permission/Prohibition (nviProhibit_n)
Monitoring Item at Upper System (n: 0~7) • On/Off State & Alarm (nvoOnOff_n) • Inlet Air Temperature (nvoInletTemp_n)

Option B HARC-BXE (B)

Connection Method to Upper System Connection by SNVT (Standard Network Variable Type) to LONWORKS® Network
Connection Quantity 32 Indoor Units (4 Indoor Units per 1 PCB)
Control Item at Upper System (n: 0~3) • On / Off Order (nviOnOff_n) • Fan Speed Setting (nviFanSpeed_n) • Operation Mode Setting (nviMode_n)
• R.C. Sw Permission/Prohibition(nviProhibit_n) • Temperature Setting (nviSetPoint_n)
• All On/Off Order (nviAllOnOff) • Louver Position Setting (nviLouver_n)
Monitoring Item at Upper System (n: 0~3) • On/Off State & Alarm (nvoOnOff_n) • Temperature Setting (nvoSetPoint_n)
• Operation Mode State (nvoMode_n) • Louver Position (nvoLouver_n) • Fan Speed Setting (nvoFanSpeed_n)
• Alarm Code (nvoAlarmDescr_n) • Inlet Air Temperature (nvoInletTemp_n)
• Outlet Air Temperature (nvoOutletTemp_n) • Outdoor Air Temperature (nvoAmbientTemp)
•T
 he number of maximum connectable refrigerant system is 8 (0 to 7). The available setting range of refrigerant system number and indoor unit address is 0 to 15.
•A
 ll indoor units connected to the PCB need to have same refrigerant system number.

109 110

083-112_SMZ_HP_CTR_0614.indd 110 2019/06/14 14:48



7 DAY TIMER
PSC-A1T
Scheduling Operation with PSC-A64S/PSC-A16RS
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×120.0×17.0

EXAMPLE OF SYSTEM CONFIGURATION

H-LINK
Remote Control Cable

· By using PSC-A1T with PSC-A64S or PSC-A16RS controllers, the air conditioners
controlled by them can be operated according to a schedule.
· The
 timer can be set at 7-day intervals, and operation/stop can be set 3 times daily.
· Remote
 control can be prohibited in accordance with the OFF time (when used with
PSC-A64S and PSC-A16RS).
· Two
 types of weekly schedule (A and B) can be set, and can easily be changed for
summer and winter.
· The
 settings are all digitally displayed, allowing operations and settings to be
checked easily.
· The
 power failure backup function prevents the timer from being stopped due to a
power failure lasting up to 2 weeks. «PSC-A1T» «PSC-A64S»

083-112_SMZ_HP_CTR_0614.indd 111 2019/06/14 14:48



3P CONNECTOR CABLE
PCC-1A
(For Connection to Remote On/Off Device/Receipt of Output Signal)
EXAMPLE OF SYSTEM CONFIGURATION

SET FREE Σ – FSNP & FSNS SERIES


«PCC-1A» 3
2
1 Thermostat

*One set contains five 3P connector cables. 3 CN3


*PCC-1A can connect to external signal input-output terminal 2
both in Outdoor Unit and Indoor Unit. 1
Temperature
Increase
Operation «example»
Cooling Operation: Remote ON/OFF device
Compressor is ON by closing terminals 2 and 3 of CN3
Compressor is OFF by opening terminals 2 and 3 of CN3 Indoor Unit PCB

Heating Operation:
Compressor is ON by closing terminals 1 and 2 of CN3 H-LINK
Compressor is OFF by opening terminals 1 and 2 of CN3 Remote Control Cable


REMOTE SENSOR
THM-R2A
(To sense the indoor temperature)
EXAMPLE OF SYSTEM CONFIGURATION SPECIFICATIONS
* When the room temperature sensing thermistor
(Remote Sensor) is attached to the auxiliary
Outer Dimensions (H×W×D)
connector, the unit is controlled at average air (mm) 50.0×50.0×15.0
temperature at the indoor inlet and Remote

CONTROLLERS
Sensor point. Length M 8.00
* Not compatible with Wall Type (RPK) indoor unit.

«THM-R2A» H-LINK
Remote Sensor Cord


REMOTE CONTROL CABLE
PRC-5K, 10K, 15K
(For PC-ARF1 and PC-AR connection (to IDU))
EXAMPLE OF SYSTEM CONFIGURATION SPECIFICATIONS

PRC-5K PRC-10K PRC-15K


H-LINK Length M 5.00 10.00 15.00
Remote Control Cable

«PRC-5K, 10K, 15K»

50mm 100mm * Neither PC‑AR or PC‑ARF1 include a remote


Shielded Twist-Pair Cable control cable.
Use this cable if you don’t have one available
in your field.

111 112

083-112_SMZ_HP_CTR_0614.indd 112 2019/06/14 14:48


Johnson Controls-Hitachi Air Conditioning
CUSTOMER SERVICE CERTIFICATION
T +81 120 578 011
[email protected] ISO 9000 series
Shimizu Air Conditioning Headquarters, Professional-Use Air Conditioning
SALES OFFICE Business Division, Johnson Controls – Hitachi Air Conditioning
JQA-1084 obtained in November 1995
T +81 50 3154 3967
[email protected]
ISO 14000 series
Shimizu Business Office, Johnson Controls – Hitachi Air Conditioning
SPARE PARTS EC97J1107 obtained in October 1997
T +81 120 649 020
[email protected]

DISTRIBUTOR