LCD Module Mcc162a4 5
LCD Module Mcc162a4 5
LCD Module Mcc162a4 5
PRODUCT SPECIFICATIONS
! PHYSICAL DATA
! EXTERNAL DIMENSIONS
! BLOCK DIAGRAM
! ABSOLUTE MAXIMUM RATINGS
! ELECTRICAL CHARACTERISTICS
! OPERATING PRINCIPLES & METHODS
! DISPLAY DATA RAM ADDRESS MAP
! ELECTRO-OPTICAL CHARACTERISTICS
! INTERFACE PIN CONNECTIONS
! PART LIST
! CIRCUIT DIAGRAM
! RELIABILITY
! QUALITY GUARANTEE
! INSPECTION CRITERIA
! PRECAUTIONS FOR USING LCD MODULES
! USING LCD MODULES
! PHYSICAL DATA
Item Contents Unit
LCD type TN ---
LCD duty 1/16 ---
LCD bias 1/5 ---
Viewing direction 6 o’clock
Module size (W×H×T) 80 × 36 × 11MAX (3.15″ × 1.42″ × 0.43″MAX) mm
Viewing area (W×H) 64.5 × 13.8 (2.54″ × 0.54″) mm
Number of characters (characters×lines) 16 × 2 ---
Character matrix (W×H) 5×8 dots
Character size (W×H) 2.95 × 4.35 (0.116″ × 0.171″) mm
Dot size (W×H) 0.55 × 0.50 (0.022″ × 0.020″) mm
Dot pitch (W×H) 0.60 × 0.55 (0.024″ × 0.022″) mm
! EXTERNAL DIMENSIONS
! BLOCK DIAGRAM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
VSS VDD VO RS R/W E DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 NC NC
DB0
~
SEG80
DB7
RS CONTROLLER IC
R/W
E KS0070B
VSS COM16 LCD PANEL
VDD 16 CHARACTERS ✕ 2 LINES
VO
◆ AC Characteristics
H Right shift
R/L
L Left shift
H 2 line display
N
L 1 line display
H 5 X 10 dots
F
L 5 X 7 dots
◆ Initializing by Instruction
Power On
|
Wait for more than 15ms after VDD rises to 4.5V
|
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF cannot be checked before this instruction.
0 0 0 0 1 1 * * * * Function Set
|
Wait for more than 4.1ms
|
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF cannot be checked before this instruction.
0 0 0 0 1 1 * * * * Function Set
|
Wait for more than 100µs
|
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF cannot be checked before this instruction.
0 0 0 0 1 1 * * * * Function Set
|
| BF can be checked after following
| instruction.
| When BF is not checked, the waiting time
| between instructions is longer than execution
instruction time.
|
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 Function Set (Specify the number of display
0 0 0 0 1 1 N F * * lines and character font.) The number of
display lines and character font cannot be
changed afterwards.
0 0 0 0 0 0 1 0 0 0 Display Off
0 0 0 0 0 0 0 0 0 1 Display Clear
0 0 0 0 0 0 0 1 I/D S Entry Mode Set
|
|
#
Initialization ends
Characters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
First line 00H 01H 02H 03H 04H 05H 06H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH
Second line 40H 41H 42H 43H 44H 45H 46H 47H 48H 49H 4AH 4BH 4CH 4DH 4EH 4FH
Note2: Definition of contrast ratio ‘Cr’. Note3: Definition of viewing angle range ‘θ’.
! PART LIST
Part Name Description Quantity
IC KS0070B.PCC 1
LCD TM002-DPRDCN 1
PCB MCC162A4-5 1
Frame MC161-1 1
Rubber connector 70.5x3.0x2.2mm YP 2
Resistor 2.2KΩ 5
Resistor 91KΩ 1
! CIRCUIT DIAGRAM
! RELIABILITY
◆ Content of Reliability Test
Environmental Test
No. Test Item Content of Test Test Condition Applicable
Standard
1 High temperature Endurance test applying the high storage 60 °C ------
storage temperature for a long time. 200 hrs
2 Low temperature Endurance test applying the low storage -10 °C ------
storage temperature for a long time. 200 hrs
3 High temperature Endurance test applying the electric stress 50 °C
operation (Voltage & Current) and the thermal stress to 200 hrs ------
the element for a long time.
4 Low temperature Endurance test applying the electric stress 0 °C ------
operation under low temperature for a long time. 200 hrs
5 High temperature / Endurance test applying the high temperature 60 °C , 90 %RH MIL-202E-103B
Humidity storage and high humidity storage for a long time. 96 hrs JIS-C5023
6 High temperature / Endurance test applying the electric stress 40 °C , 90 %RH MIL-202E-103B
Humidity operation (Voltage & Current) and temperature / 96 hrs JIS-C5023
humidity stress to the element for a long time.
7 Temperature cycle Endurance test applying the low and high -10°C / 60°C
temperature cycle. 10 cycles
-10°C 25°C 60°C ------
30min 5min. 30min
1 cycle
Mechanical Test
8 Vibration test Endurance test applying the vibration during 10∼22Hz → 1.5mmp-p MIL-202E-201A
transportation and using. 22∼500Hz → 1.5G JIS-C5025
Total 0.5hrs JIS-C7022-A-10
9 Shock test Constructional and mechanical endurance test 50G half sign MIL-202E-213B
applying the shock during transportation. wave 1l msedc
3 times of each direction
10 Atmospheric Endurance test applying the atmospheric 115 mbar MIL-202E-105C
pressure test pressure during transportation by air. 40 hrs
Others
11 Static electricity test Endurance test applying the electric stress to
VS=800V , RS=1.5 kΩ MIL-883B-3015.1
the terminal. CS=100 pF
1 time
∗∗∗ Supply voltage for logic system = 5V. Supply voltage for LCD system = Operating voltage at 25°C.
! QUALITY GUARANTEE
◆ Definition of ‘LOT’
One lot means the delivery quantity to customer at one time.
! INSPECTION CRITERIA
◆ Module Cosmetic Criteria
No. Item Judgement Criterion Partition
1 Difference in Spec. None allowed Major
2 Pattern peeling No substrate pattern peeling and floating Major
3 Soldering defects No soldering missing Major
No soldering bridge Major
No cold soldering Minor
4 Resist flaw on substrate Invisible copper foil (∅0.5mm or more) on substrate pattern Minor
5 Accretion of metallic No soldering dust Minor
Foreign matter No accretion of metallic foreign matters (Not exceed ∅0.2mm) Minor
6 Stain No stain to spoil cosmetic badly Minor
7 Plate discoloring No plate fading, rusting and discoloring Minor
8 Solder amount a. Soldering side of PCB Minor
Solder to form a ‘Filet’
1. Lead parts all around the lead.
Solder should not hide the
lead form perfectly. (too much)
b. Components side
( In case of ‘Through Hole PCB’ )
4 Scratch In accordance with spots and lines operating cosmetic criteria. When the light Minor
reflects on the panel surface, the scratches are not to be remarkable.
5 Allowable density Above defects should be separated more than 30mm each other. Minor
6 Coloration Not to be noticeable coloration in the viewing area of the LCD panels. Minor
Back-lit type should be judged with back-lit on state only.
7 Contamination Not to be noticeable. Minor
$ $
$ $
$ : Measuring points
Note :
(1) Size : d = (long length + short length) / 2
(2) The limit samples for each item have priority.
(3) Complexed defects are defined item by item, but if the number of defects are defined in above table, the total number should
not exceed 10.
(4) In case of ‘concentration’, even the spots or the lines of ‘disregarded’ size should not allowed. Following three situations
should be treated as ‘concentration’.
- 7 or over defects in circle of ∅5mm.
- 10 or over defects in circle of ∅10mm.
- 20 or over defects in circle of ∅20mm.
(8) Install the LCD Module by using the mounting holes. When mounting the LCD module make sure it is free of twisting,
warping and distortion. In particular, do not forcibly pull or bend the I/O cable or the backlight cable.
(9) Do not attempt to disassemble or process the LCD module.
(10) NC terminal should be open. Do not connect anything.
(11) If the logic circuit power is off, do not apply the input signals.
(12) To prevent destruction of the elements by static electricity, be careful to maintain an optimum work environment.
- Be sure to ground the body when handling the LCD modules.
- Tools required for assembling, such as soldering irons, must be properly grounded.
- To reduce the amount of static electricity generated, do not conduct assembling and other work under dry conditions.
- The LCD module is coated with a film to protect the display surface. Exercise care when peeling off this protective film
since static electricity may be generated.
◆ Storage Precautions
When storing the LCD modules, avoid exposure to direct sunlight or to the light of fluorescent lamps. Keep the modules in bags
(avoid high temperature / high humidity and low temperatures below 0°C). Whenever possible, the LCD modules should be stored in
the same conditions in which they were shipped from our company.
◆ Others
Liquid crystals solidify under low temperature (below the storage temperature range) leading to defective orientation or the
generation of air bubbles (black or white). Air bubbles may also be generated if the module is subject to a low temperature.
If the LCD modules have been operating for a long time showing the same display patterns, the display patterns may remain on
the screen as ghost images and a slight contrast irregularity may also appear. A normal operating status can be regained by
suspending use for some time. It should be noted that this phenomenon does not adversely affect performance reliability.
To minimize the performance degradation of the LCD modules resulting from destruction caused by static electricity etc., exercise
care to avoid holding the following sections when handling the modules.
- Exposed area of the printed circuit board.
- Terminal electrode sections.
(2) When assembling the LCM into other equipment, the spacer to the bit between the LCM and the fitting plate should have
enough height to avoid causing stress to the module surface, refer to the individual specifications for measurements. The
measurement tolerance should be ±0.1mm.
◆ Storage
When storing LCDs as spares for some years, the following precaution are necessary.
(1) Store them in a sealed polyethylene bag. If properly sealed, there is no need for dessicant.
(2) Store them in a dark place. Do not expose to sunlight or fluorescent light, keep the temperature between 0°C and 35°C.
(3) The polarizer surface should not come in contact with any other objects. (We advise you to store them in the container in
which they were shipped.)
(4) Environmental conditions :
- Do not leave them for more than 168hrs. at 60°C.
- Should not be left for more than 48hrs. at -20°C.
◆ Safety
(1) It is recommended to crush damaged or unnecessary LCDs into pieces and wash them off with solvents such as acetone and
ethanol, which should later be burned.
(2) If any liquid leakes out of a damaged glass cell and comes in contact with the hands, wash off thoroughly with soap and water.
◆ Limited Warranty
Unless agreed between TRULY and customer, TRULY will replace or repair any of its LCD modules which are found to be
functionally defective when inspected in accordance with TRULY LCD acceptance standards (copies available upon request) for a
period of one year from date of shipments. Cosmetic/visual defects must be returned to TRULY within 90 days of shipment.
Confirmation of such date shall be based on freight documents. The warranty liability of TRULY limited to repair and/or replacement
on the terms set forth above. TRULY will not be responsible for any subsequent or consequential events.