Verilog has a variety of constructs as part of it. All are aimed at providing a functionally tested and a
verified design description for the target FPGA or ASIC.
The language has a dual function – one fulfilling the need for a design description and the other fulfilling
the need for verifying the design for functionality and timing constraints like propagation delay,
critical path delay, slack, setup, and hold times.
The components of the target design can be described at different levels with the help of the
constructs in Verilog.
In Verilog HDL a module can be defined using various levels of abstraction. There are four levels of
abstraction in verilog.
They are: 1. Circuit Level 2. Gate Level 3. Data Flow Level 4. Behavioral Level
Circuit Level
At the circuit level, a switch is the basic element with which digital circuits are built. Switches can be
combined to form inverters and other gates at the next higher level of abstraction. Verilog has the
basic MOS switches built into its constructs, which can be used to build basic circuits like inverters,
basic logic gates, simple 1-bit dynamic and static memories. They can be used to build up larger
designs to simulate at the circuit level, to design performance critical circuits.
The below Figure1 shows the circuit of an inverter suitable for description with the switch level
constructs of Verilog.
At the next higher level of abstraction, design is carried out in terms of basic gates. All the basic gates are
available as ready modules called “Primitives.” Each such primitive is defined in terms of its inputs and
outputs. Primitives can be incorporated into design descriptions directly. Just as full physical
hardware can be built using gates, the primitives can be used repeatedly and judiciously to build
larger systems.
Figure 2 shows an AND gate suitable for description using the gate primitive of Verilog.
The gate level modeling or structural modeling as it is sometimes called is akin to building a digital
circuit on a bread board, or on a PCB. One should know the structure of the design to build the model
here. One can also build hierarchical circuits at this level. However, beyond 20 to 30 of such gate
primitives in a circuit, the design description becomes unwieldy; testing and debugging become
laborious.
Data Flow
Data flow is the next higher level of abstraction. All possible operations on signals and variables are
represented here in terms of assignments. All logic and algebraic operations are accommodated.
The assignments define the continuous functioning of the concerned block. At the data flow level,
signals are assigned through the data manipulating equations. All such assignments are concurrent in
nature. The design descriptions are more compact than those at the gate level.
Figure 3 shows an A-O-I relationship suitable for description with the Verilog constructs at the data
flow level.
Behavioral Level
Behavioral level constitutes the highest level of design description; it is essentially at the system level
itself. With the assignment possibilities, looping constructs and conditional branching possible, the
design description essentially looks like a “C” program.
A module can be implemented in terms of the design algorithm. The designer no need to have any
knowledge of hardware implementation.
The statements involved are “dense” in function. Compactness and the comprehensive nature of the
design description make the development process fast and efficient.
Figure 4 shows an A-O-I gate expressed in pseudo code suitable for description with the
behavioral level constructs of Verilog.
The possibilities of design description statements and assignments at different levels necessitate
their accommodation in a mixed mode. In fact the design statements coexisting in a seamless manner
within a design module is a significant characteristic of Verilog. Thus Verilog facilitates the mixing of
the above-mentioned levels of design. A design built at data flow level can be instantiated to form a
structural mode design. Data flow assignments can be incorporated in designs which are basically
at behavioral level.
Concurrency
In an electronic circuit all the units are to be active and functioning concurrently. The voltages and
currents in the different elements in the circuit can change simultaneously. In turn the logic levels too can
change. Simulation of such a circuit in an HDL calls for concurrency of operation.
A number of activities – may be spread over different modules – are to be run concurrently here.
Verilog simulators are built to simulate concurrency. (This is in contrast to programs in the normal
languages like C where execution is sequential.)
Concurrency is achieved by proceeding with simulation in equal time steps. The time step is kept
small enough to be negligible compared with the propagation delay values. All the activities
scheduled at one time step are completed and then the simulator advances to the next time step and
so on. The time step values refer to simulation time and not real time. One can redefine timescales to
suit technology as and when necessary and carry out test runs.
In some cases the circuit itself may demand sequential operation as with data transfer and memory-
based operations. Only in such cases sequential operation is ensured by the appropriate usage of
sequential constructs from Verilog HDL.
The design that is specified and entered as described earlier is simulated for functionality and fully
debugged. Translation of the debugged design into the corresponding hardware circuit (using an
FPGA or an ASIC) is called “synthesis.”
The tools available for synthesis relate more easily with the gate level and data flow level
modules [Smith MJ]. The circuits realized from them are essentially direct translations of
functions into circuit elements.
In contrast many of the behavioral level constructs are not directly synthesizable; even if
synthesized they are likely to yield relatively redundant or wrong hardware. The way out is to take the
behavioral level modules and redo each of them at lower levels. The process is carried out successively
with each of the behavioral level modules until practically the full design is available as a pack of
modules at gate and data flow levels (more commonly called the “RTL level”).
Programming Language Interface (PLI)
PLI provides an active interface to a compiled Verilog module. The interface adds a new
dimension to working with Verilog routines from a C platform. The key functions of the
interface are as follows:
• One can read data from a file and pass it to a Verilog module as input. Such data can be test
vectors or other input data to the module. Similarly, variables in Verilog modules can be
accessed and their values written to output devices.
• Delay values, logic values, etc., within a module can be accessed and altered.
• Blocks written in C language can be linked to Verilog modules.
MODULE
Any Verilog program begins with a keyword – called a “module.” A module is the name given to any
system considering it as a black box with input and output terminals as shown in Figure 1. The
terminals of the module are referred to as ‘ports’. The ports attached to a module can be of three types:
• input ports through which one gets entry into the module; they signify the input signal
terminals of the module.
• output ports through which one exits the module; these signify the output signal
terminals of the module.
• inout ports: These represent ports through which one gets entry into the module
or exits the module; These are terminals through which signals are input to the
module sometimes; at some other times signals are output from the module through
these.
Whether a module has any of the above ports and how many of each type are present depend solely on
the functional nature of the module. Thus one module may not have any port at all; another may have
only input ports, while a third may have only output ports, and so on.
All the constructs in Verilog are centered on the module. They define ways of building up,
accessing, and using modules. The structure of modules and the mode of invoking them in a design
are discussed here.
A module comprises a number of “lexical tokens” arranged according to some predefined order.
The possible tokens are of seven categories:
• White spaces
• Comments
• Operators
• Numbers
• Strings
• Identifiers
• Keywords
The rules constraining the tokens and their sequencing will be dealt with as we progress. For the
present let us consider modules. In Verilog any program which forms a design description is a “module.”
Any program written to test a design description is also a “module.” The latter are often called as
“stimulus modules” or “test benches.” A module used to do simulation has the form shown in Figure
2. Verilog takes the active statements appearing between the “module” statement and the
“endmodule” statement and interprets all of them together as forming the body of the module.
Whenever a module is invoked for testing or for incorporation into a bigger design module, the
name of the module (“test” here) is used to identify it for the purpose.
LANGUAGE CONSTRUCTS AND CONVENTIONS IN VERILOG
Introduction
The constructs and conventions make up a software language. A clear understanding and
familiarity of these is essential for the mastery of the language. Verilog has its own constructs and
conventions [IEEE, Sutherland]. In many respects they resemble those of C language [Gottfried].
Any source file in Verilog (as with any file in any other programming language) is made up of a
number of ASCII characters. The characters are grouped into sets — referred to as “lexical tokens.”
A lexical token in Verilog can be a single character or a group of characters. Verilog has 7 types of lexical
tokens- operators, keywords, identifiers, white spaces, comments, numbers, and strings.
Case Sensitivity
Verilog is a case-sensitive language like C. Thus sense, Sense, SENSE, sENse,… etc., are all related as
different entities / quantities in Verilog.
Keywords
The keywords define the language constructs. A keyword signifies an activity to be carried out,
initiated, or terminated. As such, a programmer cannot use a keyword for any purpose other than that
it is intended for. All keywords in Verilog are in small letters and require to be used as such (since
Verilog is a case-sensitive language). All keywords appear in the text in New Courier Bold-type letters.
Examples
Identifiers
Any program requires blocks of statements, signals, etc., to be identified with an attached
nametag. Such nametags are identifiers. It is good practice for us to use identifiers, closely related to
the significance of variable, signal, block, etc., concerned. This eases understanding and debugging of
any program.
e.g., clock, enable, gate_1, . . .
There are some restrictions in assigning identifier names. All characters of the alphabet or an
underscore can be used as the first character. Subsequent characters can be of alphanumeric type, or the
underscore (_), or the dollar ($) sign – for example
name, _name. Name, name1, name_$, . . . -- all these are allowed as identifiers
name aa -- not allowed as an identifier because of the blank ( “name” and “aa” are interpreted as two
different identifiers)
$name -- not allowed as an identifier because of the presence of “$” as the first character. 1_name -
- not allowed as an identifier, since the numeral “1” is the first character
@name -- not allowed as an identifier because of the presence of the character “@”. A+b m
not allowed as an identifier because of the presence of the character “+”.
Blanks (\b), tabs (\t), newlines (\n), and formfeed form the white space characters in Verilog. In any
design description the white space characters are included to improve readability. Functionally,
they separate legal tokens. They are introduced between keywords, keyword and an identifier, between
two identifiers, between identifiers and operator symbols, and so on. White space characters have
significance only when they appear inside strings.
Comments
Comments can be inserted in the code for readability and documentation. There are two ways to write
comments. A one-line comment starts with "//". Verilog skips from that point to the end of line. A
multiple-line comment starts with "/*" and ends with "*/". Multiple-line comments cannot be
nested. However, one-line comments can be embedded in multiple-line comments.
comment */
Operators are of three types: unary, binary, and ternary. Unary operators precede the operand. Binary
operators appear between two operands. Ternary operators have two separate operators that
separate three operands.
Number Specification
There are two types of number specification in Verilog: sized and unsized.
Sized numbers
Sized numbers are represented as <size> '<base format> <number>.
<size> is written only in decimal and specifies the number of bits in the number. Legal base formats
are decimal ('d or 'D), hexadecimal ('h or 'H), binary ('b or 'B) and octal ('o or 'O). The number is
specified as consecutive digits from 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, a, b, c, d, e, f. Only a subset of these
digits is legal for a particular base. Uppercase letters are legal for number specification.
Unsized numbers
Numbers that are specified without a <base format> specification are decimal numbers by default.
Numbers that are written without a <size> specification have a default number of bits that is
simulator- and machine-specific (must be at least 32).
X or Z values
Verilog has two symbols for unknown and high impedance values. These values are very
important for modeling real circuits. An unknown value is denoted by an x. A high impedance value is
denoted by z.
12'h13x // This is a 12-bit hex number; 4 least significant bits unknown 6'hx
An x or z sets four bits for a number in the hexadecimal base, three bits for a number in the octal
base, and one bit for a number in the binary base. If the most significant bit of a number is 0, x, or z, the
number is automatically extended to fill the most significant bits, respectively, with 0, x, or z. This
makes it easy to assign x or z to whole vector. If the most significant digit is 1, then it is also zero
extended.
Negative numbers
Negative numbers can be specified by putting a minus sign before the size for a constant number.
Size constants are always positive. It is illegal to have a minus sign between <base format> and
<number>. An optional signed specifier can be added for signed arithmetic.
-6'd3 // 8-bit negative number stored as 2's complement of 3 -6'sd3 // Used for performing signed
integer math 4'd-2 // Illegal specification
An underscore character "_" is allowed anywhere in a number except the first character.
Underscore characters are allowed only to improve readability of numbers and are ignored by Verilog.
A question mark "?" is the Verilog HDL alternative for z in the context of numbers.
12'b1111_0000_1010 // Use of underline characters for readability
Strings
A string is a sequence of characters that are enclosed by double quotes. The restriction on a string is
that it must be contained on a single line, that is, without a carriage return. It cannot be on multiple lines.
Strings are treated as a sequence of one-byte ASCII values.
Verilog supports four values and eight strengths to model the functionality of real hardware. The
four value levels are listed in Table below.
Strengths
The logic levels are also associated with strengths. In many digital circuits, multiple assignments are often
combined to reduce silicon area or to reduce pin-outs. To facilitate this, one can assign strengths
to logic levels. Verilog has eight strength levels – four of these are of the driving type, three are of
capacitive type and one of the hi-Z type.
In addition to logic values, strength levels are often used to resolve conflicts between drivers of different
strengths in digital circuits. Value levels 0 and 1 can have the strength levels listed in Table below
If two signals of unequal strengths are driven on a wire, the stronger signal prevails.
For example, if two signals of strength strong1 and weak0 contend, the result is resolved as a strong1.
If two signals of equal strengths are driven on a wire, the result is unknown. If two signals of
strength strong1 and strong0 conflict, the result is an x. Strength levels are particularly useful for
accurate modeling of signal contention, MOS devices, dynamic MOS, and other low-level devices.
Data Types
The two types differ in the way they are used as well as with regard to their respective hardware
structures. Data type of each variable or signal has to be declared prior to its use. The same is valid
within the concerned block or module.
Nets
A net signifies a connection from one circuit unit to another. Such a net carries the value of the signal it
is connected to and transmits to the circuit blocks connected to it. If the driving end of a net is left
floating, the net goes to the high impedance state. A net can be specified in different ways.
wire: It represents a simple wire doing an interconnection. Only one output is connected to a wire and
is driven by that.
tri: It represents a simple signal line as a wire. Unlike the wire, a tri can be driven by more than one
signal outputs.
Nets are one-bit values by default unless they are declared explicitly as vectors. The terms wire and net
are often used interchangeably.
A variable is an abstraction for a storage device. It can be declared through the keyword reg and
stores the value of a logic level: 0, 1, x, or z. A net or wire connected to a reg takes on the value stored
in the reg and can be used as input to other circuit elements. But the output of a circuit cannot be
connected to a reg. The value stored in a reg is changed through a fresh assignment in the program.
time, integer, real, and realtime are the other variable types of data; these are dealt with later.
Time
Verilog simulation is done with respect to simulation time. A special time register data type is used in
Verilog to store simulation time. A time variable is declared with the keyword time. The width for time
register data types is implementation-specific but is at least 64 bits. The system function $time is
invoked to get the current simulation time.
Entities representing single bits — whether the bit is stored, changed, or transferred — are called
“scalars.” Often multiple lines carry signals in a cluster – like data bus, address bus, and so on. Similarly,
a group of regs stores a value, which may be assigned, changed, and handled together. The collection
here is treated as a “vector.”
Figure below illustrates the difference between a scalar and a vector. wr and rd are two scalar nets
connecting two circuit blocks circuit1 and circuit2. b is a 4-bit-wide vector net connecting the same
two blocks. b[0], b[1], b[2], and b[3] are the individual bits of vector b. They are “part vectors.”
A vector reg or net is declared at the outset in a Verilog program and hence treated as such. The range
of a vector is specified by a set of 2 digits (or expressions evaluating to a digit) with a colon in between
the two. The combination is enclosed within square brackets.
Examples:
wire[3:0] a; /* a is a four bit vector of net type; the bits are designated as a[3], a[2], a[1] and a[0]. */
reg[2:0] b; /* b is a three bit vector of reg type; the bits are designated as b[2], b[1] and b[0]. */
reg[4:2] c; /* c is a three bit vector of reg type; the bits are designated as c[4], c[3] and c[2]. */
wire[-2:2] d ; /* d is a 5 bit vector with individual bits designated as d[-2], d[-1], d[0], d[1] and d[2]
*/
Whenever a range is not specified for a net or a reg, the same is treated as a scalar – a single bit quantity. In
the range specification of a vector the most significant bit and the least significant bit can be assigned
specific integer values. These can also be expressions evaluating to integer constants – positive or
negative.
Normally vectors – nets or regs – are treated as unsigned quantities. They have to be specifically
declared as “signed” if so desired.
Examples
Introduction
Digital designers are normally familiar with all the common logic gates, their symbols, and their
working. Flip-flops are built from the logic gates. All other functionally complex and more
involved circuits can also be built using the basic gates. All the basic gates are available as
“Primitives” in Verilog. Primitives are generalized modules that already exist in Verilog [IEEE]. They
can be instantiated directly in other modules.
The AND gate primitive in Verilog is instantiated with the following statement: and
Here ‘and’ is the keyword signifying an AND gate. g1 is the name assigned to the specific
instantiation. O is the gate output; I1, I2, etc., are the gate inputs. The following are noteworthy:
• The AND module has only one output. The first port in the argument list is the output port.
• An AND gate instantiation can take any number of inputs — the upper limit is compiler-
specific.
• A name need not be necessarily assigned to the AND gate instantiation; this is true of all the gate
primitives available in Verilog.
The truth table for a two-input AND gate is shown in Table below It can be directly extended to AND
gate instantiations with multiple inputs. The following observations are in order here:
Input 1
0 1 X z
0 0 0 0 0
Input 2 1 0 1 X x
x 0 x X x
z 0 x X x
• If any one of the inputs to the AND gate instantiation is in the 0 state, its output is also in the 0
state. It is irrespective of whether the other inputs are at the 0, 1, x or z state.
• The output is at 1 state if and only if every one of the inputs is at 1 state.
• Note that the output is never at the z state – the high impedance state. This is true of all other
gate primitives as well.
Module Structure
In a general case a module can be more elaborate. A lot of flexibility is available in the definition
of the body of the module. However, a few rules need to be followed:
• The first statement of a module starts with the keyword module; it may be followed by the
name of the module and the port list if any.
• All the variables in the ports-list are to be identified as inputs, outputs, or inouts. The
corresponding declarations have the form shown below:
The port-type declarations here follow the module declaration mentioned above.
• The ports and the other variables used within the body of the module are to be identified
as nets or registers with specific types in each case. The respective declaration statements follow
the port-type declaration statements.
Examples:
The type declaration must necessarily precede the first use of any variable or signal in the module.
• The executable body of the module follows the declaration indicated above.
All other basic gates are also available as primitives in Verilog. Details of the facilities and
instantiations in each case are given in Table below. The following points are noteworthy here:
• In all cases of instantiations, one need not necessarily assign a name to the instantiation.
It need be done only when felt necessary – say for clarity of circuit description.
• In all the cases the output port(s) is (are) declared first and the input port(s) is (are)
declared subsequently.
• The buffer and the inverter have only one input each. They can have any number of outputs;
the upper limit is compiler-specific. All other gates have one output each but can have any
number of inputs; the upper limit is again compiler-specific.
The commonly used A-O-I gate is shown in Figure 1 for a simple case. The module and the test bench for
the same are given in Figure 2. The circuit has been realized here by instantiating the AND and NOR gate
primitives. The names of signals and gates used in the instantiations in the module of Figure 2 remain
the same as those in the circuit of Figure 1. The module aoi_gate in the figure has input and output
ports since it describes a circuit with signal inputs and an output. The module aoi_st is a stimulus
module. It generates inputs to the aoi_gate module and gets its output. It has no input or output ports.
/*module for the aoi-gate of figure 1 instantiating the gate primitives – fig 2*/ module
aoi_gate(o,a1,a2,b1,b2);
wire o1,o2; //o1 and o2 are intermediate signals //within the module and
nor g3(o,o1,o2); //The nor gate has one instantiation with assigned name g3.
endmodule
Tri-State Gates
Four types of tri-state buffers are available in Verilog as primitives. Their outputs can be turned ON or
OFF by a control signal. The direct buffer is instantiated as
Bufif1 nn (out, in, control);
When
control = 0,
out=tri-stated
out is cut off from the input and tri-stated. The output, input and control signals should appear
in the instantiation in the same order as above. Details of bufif1 as well as the other tri-state type
primitives are shown in Table 1.
In all the cases shown in Table 1, out is the output; in is the input, and control, the control
variable.
The primitives available in Verilog can also be instantiated as arrays. A judicious use of such array
instantiations often leads to compact design descriptions. A typical array instantiation has the form
where a, b, and c are to be 4 bit vectors. The above instantiation is equivalent to combining the
following 4 instantiations:
and gate [7] (a[3], b[3], c[3]), gate [6] (a[2], b[2], c[2]), gate [5] (a[1], b[1], c[1]), gate [4]
(a[0], b[0], c[0]);
The assignment of different bits of input vectors to respective gates is implicit in the basic
declaration itself. A more general instantiation of array type has the form
Gate Delays
Until now, we described circuits without any delays (i.e., zero delay). In real circuits, logic gates
have delays associated with them. Gate delays allow the Verilog user to specify delays through the
logic circuits. Pin-to-pin delays can also be specified in Verilog.
There are three types of delays from the inputs to the output of a primitive gate.
Rise delay
The rise delay is associated with a gate output transition to a 1 from another value.
Fall delay
The fall delay is associated with a gate output transition to a 0 from another value.
Turn-off delay
The turn-off delay is associated with a gate output transition to the high impedance value
(z) from another value.
Three types of delay specifications are allowed. If only one delay is specified, this value
is used for all transitions. If two delays are specified, they refer to the rise and fall delay
values. The turn-off delay is the minimum of the two delays. If all three delays are
specified, they refer to rise, fall, and turn-off delay values. If no delays are specified, the
default value is zero.
Example--Types of Delay Specification
and #(5) a1(out, i1, i2); //Delay of 5 for all transitions and #(4,6) a2(out, i1, i2); // Rise
= 4, Fall = 6
Dataflow Modeling
Introduction
For small circuits, the gate-level modeling approach works very well because the
number of gates is limited and the designer can instantiate and connect every gate
individually. Also, gate-level modeling is very intuitive to a designer with a basic
knowledge of digital logic design. However, in complex designs the number of gates is very
large. Thus, designers can design more effectively if they concentrate on implementing
the function at a level of abstraction higher than gate level. Dataflow modeling provides a
powerful way to implement a design. Verilog allows a circuit to be designed in terms of the
data flow between registers and how a design processes data rather than instantiation of
individual gates. Later in this chapter, the benefits of dataflow modeling will become more
apparent.
With gate densities on chips increasing rapidly, dataflow modeling has assumed great
importance. No longer can companies devote engineering resources to handcrafting entire
designs with gates. Currently, automated tools are used to create a gate-level circuit from a
dataflow design description. This process is called logic synthesis. Dataflow modeling
has become a popular design approach as logic synthesis tools have become sophisticated.
This approach allows the designer to concentrate on optimizing the circuit in terms of
data flow. For maximum flexibility in the design process, designers typically use a Verilog
description style that combines the concepts of gate-level, data flow, and behavioral design.
In the digital design community, the term RTL (Register Transfer Level) design is
commonly used for a combination of dataflow modeling and behavioral modeling.
Continuous Assignments
A continuous assignment is the most basic statement in dataflow modeling, used to drive a
value onto a net. This assignment replaces gates in the description of the circuit and
describes the circuit at a higher level of abstraction. The assignment statement starts
with the keyword assign. The syntax of an assign statement is as follows.
Notice that drive strength is optional and can be specified in terms of strength levels The
default value for drive strength is strong1 and strong0. The delay value is also optional and
can be used to specify delay on the assign statement. This is like specifying delays for
gates. Delay specification is discussed in this chapter.
Continuous assignments have the following characteristics:
1. The left hand side of an assignment must always be a scalar or vector net or a
concatenation of scalar and vector nets. It cannot be a scalar or vector register.
2. Continuous assignments are always active. The assignment expression is evaluated
as soon as one of the right-hand-side operands changes and the value is assigned to the left-
hand-side net.
3. The operands on the right-hand side can be registers or nets or function calls.
Registers or nets can be scalars or vectors.
4. Delay values can be specified for assignments in terms of time units. Delay values are used to
control the time when a net is assigned the evaluated value. This feature is similar to
specifying delays for gates. It is very useful in modeling timing behavior in real circuits.
Continuous assign. out is a net. i1 and i2 are nets. assign out = i1 & i2;
Continuous assign for vector nets. addr is a 16-bit vector net addr1
Instead of declaring a net and then writing a continuous assignment on the net, Verilog
provides a shortcut by which a continuous assignment can be placed on a net when it is
declared. There can be only one implicit declaration assignment per net because a net is
declared only once.
wire out;
//Same effect is achieved by an implicit continuous assignment wire out = in1 &
in2;
If a signal name is used to the left of the continuous assignment, an implicit net
declaration will be inferred for that signal name. If the net is connected to a module port,
the width of the inferred net is equal to the width of the module port.
assign out = i1 & i2; //Note that out was not declared as a wire
Delays
Delay values control the time between the change in a right-hand-side operand and when the
new value is assigned to the left-hand side. Three ways of specifying delays
in continuous assignment statements are regular assignment delay, implicit
continuous assignment delay, and net declaration delay.
The first method is to assign a delay value in a continuous assignment statement. The
delay value is specified after the keyword assign. Any change in values of in1 or in2 will
result in a delay of 10 time units before recomputation of the expression in1 & in2, and the
result will be assigned to out. If in1 or in2 changes value again before 10 time units when
the result propagates to out, the values of in1 and in2 at the time of recomputation are
considered. This property is called inertial delay. An input pulse that is shorter than the delay
of the assignment statement does not propagate to the output.
Figure: Delays
The above waveform is generated by simulating the above assign statement. It shows the
delay on signal out. Note the following change:
When signals in1 and in2 go high at time 20, out goes to a high 10 time units later
(time = 30).
However, in1 changes to high at 80, but it goes down to low before 10 time units
have elapsed.
Hence, at the time of recomputation, 10 units after time 80, in1 is 0. Thus, out gets the value 0.
A pulse of width less than the specified assignment delay is not propagated to the output.
An equivalent method is to use an implicit continuous assignment to specify both a delay and an
assignment on the net.
//same as wire
out;
The declaration above has the same effect as defining a wire out and declaring a
continuous assignment on out.
//Net Delays
wire # 10 out;
//The above statement has the same effect as the following. wire out;
Expressions
Expressions are constructs that combine operators and operands to produce a result.
Operands
Some constructs will take only certain types of operands. Operands can be constants,
integers, real numbers, nets, registers, times, bit-select (one bit of vector net or a vector
register), part-select (selected bits of the vector net or register vector), and memories
or function calls (functions are discussed later).
real a, b, c;
reg ret_value;
Operators act on the operands to produce desired results. Verilog provides various types of
operators.
Operator Types
Verilog provides many different operator types. Operators can be arithmetic, logical,
relational, equality, bitwise, reduction, shift, concatenation, or conditional. Some of these
operators are similar to the operators used in the C programming language. Each operator
type is denoted by a symbol. The following table shows the complete listing of operator
symbols classified by category.
* multiply two
/ divide two
+ add two
Arithmetic
- subtract two
% modulus two
|| logical or two
Relational
>= greater than or equal two
== equality two
!= inequality two
Equality
=== case equality two
| reduction or one
Reduction
~| reduction nor one
Shift
>>> Arithmetic right shift Two
Arithmetic Operators
Binary operators
Binary arithmetic operators are multiply (*), divide (/), add (+), subtract (-), power (**),
and modulus (%). Binary operators take two operands.
If any operand bit has a value x, then the result of the entire expression is x. This seems
intuitive because if an operand value is not known precisely, the result should be an
unknown.
in1 = 4'b101x;
in2 = 4'b1010;
Modulus operators produce the remainder from the division of two numbers. They
operate similarly to the modulus operator in the C programming language.
13 % 3 // Evaluates to 1
16 % 4 // Evaluates to 0
Unary operators
The operators + and - can also work as unary operators. They are used to specify the
positive or negative sign of the operand. Unary + or ? operators have higher precedence
than the binary + or ? operators.
-4 // Negative 4
+5 // Positive 5
Logical Operators
Logical operators are logical-and (&&), logical-or (||) and logical- not (!). Operators &&
and || are binary operators. Operator ! is a unary operator. Logical operators follow
these conditions:
Logical operations A = 3;
B = 0;
Unknowns
A = 2'b0x; B = 2'b10;
Relational Operators
Relational operators are greater-than (>), less-than (<), greater-than-or-equal-to (>=), and less-
than-or-equal-to (<=). If relational operators are used in an expression, the expression
returns a logical value of 1 if the expression is true and 0 if the expression is false. If there are any
unknown or z bits in the operands, the expression takes a value x. These operators function
exactly as the corresponding operators in the C programming language.
A = 4, B = 3
// Evaluates to an x
Equality Operators
Equality operators are logical equality (==), logical inequality (!=), case equality (===), and
case inequality (!==) . When used in an expression, equality operators return logical value 1 if
true, 0 if false. These operators compare the two operands bit by bit, with zero filling if the
operands are of unequal length. Table below lists the operators.
It is important to note the difference between the logical equality operators (==, !=) and case
equality operators (===, !==). The logical equality operators (==, !=) will yield an x if either
operand has x or z in its bits. However, the case equality operators ( ===, !== ) compare both
operands bit by bit and compare all bits, including x and z. The result is 1 if the operands match
exactly, including x and z bits. The result is 0 if the operands do not match exactly. Case equality
operators never result in an x.
Table: Equality Operators
Possible Logical
Expression Description
Value
a != b 0, 1, x
B
A = 4, B = 3
X = 4'b1010, Y = 4'b1101
== B // Results in logical 0
X != Y // Results in logical 1
X == Z // Results in x
Z === N // Results in logical 0 (least significant bit does not match) M !== N //
Results in logical 1
Bitwise Operators
Bitwise operators are negation (~), and(&), or (|), xor (^), xnor (^~, ~^). Bitwise
operators perform a bit-by-bit operation on two operands. They take each bit in one
operand and perform the operation with the corresponding bit in the other operand. If one
operand is shorter than the other, it will be bit-extended with zeros to match the length of
the longer operand. Logic tables for the bit-by-bit computation are shown in Table. A z
is treated as an x in a bitwise operation. The exception is the unary negation operator (~),
which takes only one operand and operates on the bits of the single operand.
X = 4'b1010, Y = 4'b1101 Z
= 4'b10x1
It is important to distinguish bitwise operators ~, &, and | from logical operators !, &&, ||.
Logical operators always yield a logical value 0, 1, x, whereas bitwise operators yield a
bit-by-bit value. Logical operators perform a logical operation, not a bit-by-bit operation.
// X = 4'b1010, Y = 4'b0000
Reduction Operators
Reduction operators are and (&), nand (~&), or (|), nor (~|), xor (^), and xnor (~^, ^~).
Reduction operators take only one operand. Reduction operators perform a bitwise
operation on a single vector operand and yield a 1-bit result. The difference is that bitwise
operations are on bits from two different operands, whereas reduction operations are on
the bits of the same operand. Reduction operators work bit by bit from right to left.
Reduction nand, reduction nor, and reduction xnor are computed by inverting the result
of the reduction and, reduction or, and reduction xor, respectively.
// X = 4'b1010
//A reduction xor or xnor can be used for even or odd parity
//generation of a vector.
The use of a similar set of symbols for logical (!, &&, ||), bitwise (~, &, |, ^), and
reduction operators (&, |, ^) is somewhat confusing initially. The difference lies in the
number of operands each operator takes and also the value of results computed.
Shift Operators
Shift operators are right shift ( >>), left shift (<<), arithmetic right shift (>>>), and
arithmetic left shift (<<<). Regular shift operators shift a vector operand to the right or the
left by a specified number of bits. The operands are the vector and the number of bits
to shift. When the bits are shifted, the vacant bit positions are filled with zeros. Shift
operations do not wrap around. Arithmetic shift operators use the context of the
expression to determine the value with which to fill the vacated bits.
// X = 4'b1100
0;
Shift operators are useful because they allow the designer to model shift operations, shift-
and-add algorithms for multiplication, and other useful operations.
Concatenation Operator
Replication Operator
reg A;
reg [1:0] B, C;
reg [2:0] D;
Conditional Operator
Operator Precedence
Highest
Unary +-!~ precedence
Add, Subtract +-
&, ~&
Reduction ^ ^~
|, ~|
&&
Logical
||
Introduction
Behavioral modeling is the highest level of abstraction in the Verilog HDL. The other modeling
techniques are relatively detailed. They require some knowledge of how hardware or hardware signals
work. The abstraction in this modeling is as simple as writing the logic in C language. This is a very
powerful abstraction technique. All that a designer need is the algorithm of the design, which is the
basic information for any design.
Most of the behavioral modeling is done using two important constructs: initial and always. All the
other behavioral statements appear only inside these two structured procedure constructs.
The statements which come under the initial construct constitute the initial block. The initial block
is executed only once in the simulation, at time 0. If there is more than one initial block, then all the
initial blocks are executed concurrently. The initial construct is used as follows:
initial
begin
reset=1'b0;
clk=1'b1;
end
or
initial
clk = 1'b1;
In the first initial block there are more than one statements hence they are written between begin
and end. If there is only one statement then there is no need to put begin and end.
The statements which come under the always construct constitute the always block. The always block
starts at time 0, and keeps on executing all the simulation time. It works like a infinite loop. It is generally
used to model a functionality that is continuously repeated.
always
#5clk=~clk;
initial
clk = 1'b0;
The above code generates a clock signal clk, with a time period of 10 units. The initial blocks initiates the clk
value to 0 at time 0. Then after every 5 units of time it toggled, hence we get a
time period of 10 units. This is the way in general used to generate a clock signal for use in test benches.
In the above example, the always block will be executed whenever there is a positive edge in the clk signal,
or there is negative edge in the reset signal. This type of always is generally used in implement a FSM,
which has a reset signal.
always @(b,c,d)
begin
a = ( b + c )*d;
e = b | c;
end
In the above example, whenever there is a change in b, c, or d the always block will be executed. Here the
list b, c, and d is called the sensitivity list.
In the Verilog 2000, we can replace always @(b,c,d) with always @(*), it is equivalent to include all input
signals, used in the always block. This is very useful when always blocks are used for implementing the
combination logic.
The design description at the behavioral level is done through a sequence of assignments. These are called
‘procedural assignments’ – in contrast to the continuous assignments at the data flow level. Though it
appears similar to the assignments at the data flow level discussed in the last chapter, the two are
different. The procedure assignment is characterized by the following:
• The assignment is done through the “=” symbol (or the “<=” symbol) as was the case with the
continuous assignment earlier.
• An operation is carried out and the result assigned through the “=” operator to an operand
specified on the left side of the “=” sign – for example,N = ~N;
• Here the content of reg N is complemented and assigned to the reg N itself. The assignment
is essentially an updating activity.
• The operation on the right can involve operands and operators. The operands can be of different
types – logical variables, numbers – real or integer and so on.
wait CONSTRUCT
The wait construct makes the simulator wait for the specified expression to be true before
proceeding with the following assignment or group of assignments. Its syntax has the form
wait (alpha) assignment1;
alpha can be a variable, the value on a net, or an expression involving them. If alpha is an
expression, it is evaluated; if true, assignment1 is carried out. One can also have a group of
assignments within a block in place of assignment1.
Example:
wait(clk) #2 a = b;
The simulator waits for the clock to be high and then assigns b to a with a delay of 2 ns. The
assignment will be refreshed as long as the clk remains high.
The below code shows one version of the up-down counter module along with a test bench. It is a
modification of the up down counter uses a wait construct. It has an enable input En. The counter is
active and counts only when En = 1.
Verilog code:
module ctr_wt(a,clk,N,En);
input clk,En;
input[3:0]N;
output[3:0]a;
reg[3:0]a;
initial a=4'b1111;
always
begin
wait(En)
@(negedge clk)
a=(a==N)?4'b0000:a+1'b1;
end
endmodule
Test
Bench
module tst_ctr_wt; reg
clk,En; reg[3:0]N;
wire[3:0]a;
ctr_wt c1(a,clk,N,En);
initial
begin
clk=0;N=4'b1111;En=1'b0;#5 En=1'b1;#20 En=1'b0;
end
always
#2 clk=~clk;
initial #35 $stop;
initial $monitor($time,"clk=%h,En=%b,N=%b,a=%b",clk,En,N,a,);
endmodule
Procedural Assignments
Procedural assignments are used for updating reg, integer, time, real, realtime, and memory data types. The
variables will retain their values until updated by another procedural assignment.
There is a significant difference between procedural assignments and continuous assignments. Continuous
assignments drive nets and are evaluated and updated whenever an input operand changes value. Whereas
procedural assignments update the value of variables under the control of the procedural flow constructs
that surround them.
There are two types of procedural assignments: blocking and non-blocking assignments.
Blocking assignments: A blocking assignment statements are executed in the order they are specified in a
sequential block. The execution of next statement begins only after the completion of the present blocking
assignments. A blocking assignment will not block the execution of the next statement in a parallel
block. The blocking assignments are made using the operator =.
initial
begin
a = 1;
b = #5 2;
c = #2 3;
end
In the above example, a is assigned value 1 at time 0, and b is assigned value 2 at time 5, and c is assigned
value 3 at time 7.
Non-blocking assignments: The nonblocking assignment allows assignment scheduling without blocking
the procedural flow. The nonblocking assignment statement can be used whenever several variable
assignments within the same time step can be made without regard to order or dependence upon each
other. Non-blocking assignments are made using the operator <=.
Note: <= is same for less than or equal to operator, so whenever it appears in a expression it is
considered to be comparison operator and not as non-blocking assignment.
initial
begin
a <= 1;
b <= #5 2;
c <= #2 3;
end
In the above example, a is assigned value 1 at time 0, and b is assigned value 2 at time 5, and c is assigned value 3 at
time 2 (because all the statements execution starts at time 0, as they are non- blocking assignments.
The condition (if-else) statement is used to make a decision whether a statement is executed or not. The
keywords if and else are used to make conditional statement. The conditional statement can appear in the
following forms.
if ( condition_1 )
statement_1;
if ( condition_2 )
statement_2;
else
statement_3;
if ( condition_3 )
statement_4;
else if ( condition_4 )
statement_5;
else
statement_6;
if ( condition_5 )
begin
statement_7;
statement_8;
end
else
begin
statement_9;
statement_10; end
Conditional (if-else) statement usage is similar to that if-else statement of C programming language, except
that parenthesis are replaced by begin and end.
Case Statement
The case statement is a multi-way decision statement that tests whether an expression matches one of the
expressions and branches accordingly. Keywords case and endcase are used to make a case statement. The
case statement syntax is as follows.
If there are multiple statements under a single match, then they are grouped using begin, and end
keywords. The default item is optional.
casez treats high-impedance values (z) as don't cares. casex treats both high-impedance (z) and unknown (x)
values as don't cares. Don't-care values (z values for casez, z and x values for casex) in any bit of either the
case expression or the case items shall be treated as don't-care conditions during the comparison, and
that bit position shall not be considered. The don't cares are represented using the ? mark.
Loop Statements
forever
repeat
while
for
Forever Loop
Forever loop is defined using the keyword forever, which Continuously executes a statement. It
terminates when the system task $finish is called. A forever loop can also be ended by using the disable
statement.
initial
begin
clk = 1'b0;
forever #5 clk = ~clk;
end
In the above example, a clock signal with time period 10 units of time is obtained.
Repeat Loop
Repeat loop is defined using the keyword repeat. The repeat loop block continuously executes the block
for a given number of times. The number of times the loop executes can be mention using a constant or an
expression. The expression is calculated only once, before the start of loop and not during the execution of
the loop. If the expression value turns out to be z or x, then it is treated as zero, and hence loop block is
not executed at all.
initial
begin
a = 10;
b = 5;
b <= #10 10;
i = 0;
repeat(a*b)
begin
$display("repeat in progress");
#1 i = i + 1;
end
end
In the above example the loop block is executed only 50 times, and not 100 times. It
calculates (a*b) at the beginning, and uses that value only.
While Loop
The while loop is defined using the keyword while. The while loop contains an expression. The loop
continues until the expression is true. It terminates when the expression is false. If the calculated
value of expression is z or x, it is treated as a false. The value of expression is calculated each time
before starting the loop. All the statements (if more than one) are mentioned in blocks which
begins and ends with keyword begin and end keywords.
initial
begin
a = 20;
i = 0;
while (i < a)
begin
$display("%d",i);
i = i + 1;
a = a - 1;
end
end
In the above example the loop executes for 10 times. (Observe that a is decrementing by one and i is
incrementing by one, so loop terminated when both i and a become 10).
For Loop
The For loop is defined using the keyword for. The execution of for loop block is controlled by a three
step process, as follows:
Executes an assignment, normally used to initialize a variable that controls the number of times the for
block is executed.
Evaluates an expression, if the result is false or z or x, the for-loop shall terminate, and if it is true, the for-
loop shall execute its block.
Executes an assignment normally used to modify the value of the loop-control variable and then repeats
with second step.
Note that the first step is executed only once.
initial
begin
a = 20;
for (i = 0; i < a; i = i + 1, a = a - 1)
$display("%d",i);
end
The above example produces the same result as the example used to illustrate the functionality of the
while loop.
Examples:
output out;
out;
always @(*)
begin
case ({s1,s0})
2'b00: out = in0;
2'b01: out = in1;
2'b10: out = in2;
2'b11: out = in3;
default: out = 1'bx;
endcase
end
endmodule
2. Implementation of a full adder.
always @(*)
{c_out, sum} = in0 + in1 + c_in;
endmodule
endmodule
Implementation of a 8-bit counter is a very good example, which explains the advantage of
behavioral modeling. Just imagine how difficult it will be implementing a 8-bit counter using gate- level
modeling.
In the above example the incrementation occurs on every positive edge of the clock. When count becomes
8'hFF, the next increment will make it 8'h00, hence there is no need of any modulus operator. Reset
signal is active low.
Block Statements
Block statements are used to group two or more statements together, so that theyact as one statement.
There are two types of blocks:
• Sequential block.
• Parallel block.
Sequential block:
The sequential block is defined using the keywords begin and end. The procedural statements in sequential
block will be executed sequentially in the given order. In sequential block delay values for each statement
shall be treated relative to the simulation time of the execution of the previous statement. The
control will pass out of the block after the execution of last statement.
Parallel block:
The parallel block is defined using the keywords fork and join. The procedural statements in parallel
block will be executed concurrently. In parallel block delay values for each statement are considered to be
relative to the simulation time of entering the block. The delay control can be used to provide time-
ordering for procedural assignments.
The control shall pass out of the block after the execution of the last time-ordered statement. Note that
blocks can be nested. The sequential and parallel blocks can be mixed. Block names:
All the blocks can be named, by adding : block_name after the keyword begin or fork. The
advantages of naming a block are:
It allows to declare local variables, which can be accessed by using hierarchical name referencing. They can
be disabled using the disable statement (disable block_name;).
SWITCH LEVELMODELING
Introduction
In today’s environment the MOS transistor is the basic element around which a VLSI is built.
Designers familiar with logic gates and their configurations at the circuit level may choose to do their
designs using MOS transistors.
Verilog has the provision to do the design description at the switch level using such MOS
transistors.
Switch level modeling forms the basic level of modeling digital circuits.
The switches are available as primitives in Verilog; they are central to design description at this level.
Basic gates can be defined in terms of such switches. By repeated and successive instantiation of
such switches, more involved circuits can be modeled – on the same lines as was done with the gate
level primitives.
Consider an NMOS transistor of the depletion type. When used in a digital circuit, it can be in one of
three modes:
• VG < VS where VG and VS are the gate and source voltages with respect to the drain: The
transistor is OFF and offers very high impedance across the source and the drain. It is in the z
state.
• VG = VS: The transistor is in the active region. It presents a resistance between the source
and the drain. The value depends on the technology. Such a resistive state of the transistor can be
modeled in Verilog. A transistor in this mode can be represented as a resistance in Verilog – as
pull1 or pull0 depending on whether the drain is connected to supply1 or source is connected
to supply0.
• VG > VS: The transistor is fully turned on. It presents very low resistance between the source
and drain.
• An enhanced-mode NMOS transistor also has the above three modes of operation.
• It is OFF when VG = VS. It is moderately ON or in the active region when VG is slightly
greater than VS, representing a resistive (pull1 or pull0) mode of operation. When VG is
sufficiently greater than VS, the transistor is in the on state representing very low
resistance. Similar modes are possible for the PMOS transistor also.
Resistive Switches
nmos and pmos represent switches of low impedance in the on-state. rnmos and rpmos represent
the resistive counterparts of these respectively. Typical instantiations have the form
rnmos (output1, input1, control1);
rpmos (output2, input2, control2);
The rnmos if the control1 input is at 1 (high) state, the switch is ON and functions as a definite
resistance. It connects input1 to output1 through a resistance. When control1 is at the 0 (low) state, the
switch is OFF and leaves output1 floating.
The rpmos switch is ON when control2 is at 0 (low) state. It inserts a definite resistance between
the input and the output signals but retains the signal value.
rpmos and rnmos are resistive switches, they reduce the signal strength when in the on state. The
reduced strength is mostly one level below the original strength.
The rpmos and rnmos switches function as unidirectional switches; the signal flow is from the input to
the output side.
A MOS transistor functions as a resistive element when in the active state. Realization of
resistance in this form takes less silicon area in the IC as compared to a resistance realized directly.
pullup and pulldown represent such resistive elements.
pulldown (y);
pulls y down to the supply0 level through a resistance. The pullup and pulldown primitives can be used
as loads for switches or to connect the unused input ports to VCC or GND, respectively. They can also
form loads of switches in logic circuits.
The default strengths for pullup and pulldown are pull1 and pull0 respectively. One can also specify
strength values for the respective nets. For example,
specifies a resistive pullup of net x to supply1. One can also assign names to the pullup and pulldown
primitives. Thus
CMOS SWITCH
A CMOS switch is formed by connecting a PMOS and an NMOS switch in parallel – the input leads
are connected together on the one side and the output leads are connected together on the other side.
Figure 10.15 shows the switch so formed. It has two control inputs:
• N_control turns ON the NMOS transistor and keeps it ON when it is in the 1 state.
• P_control turns ON the PMOS transistor and keeps it ON when it is in the 0 state.
Verilog has a set of primitives for bi-directional switches as well. They connect the nets on either
side when ON and isolate them when OFF. The signal flow can be in either direction. None of the
continuous-type assignments at higher levels dealt with so far has a functionality equivalent to the bi-
directional gates. There are six types of bi-directional gates.
• tran rtran
• tranif1 rtanif1
• tranif0 rtranif0
tran and rtran
The tran gate is a bi-directional gate of two ports. When instantiated, it connects the two ports directly.
Thus the instantiation
connects the signal lines s1 and s2. Either line can be input, inout or output. rtran is
the resistive counterpart of tran.
Here c is the control line. If c=1, s1 and s2 are connected and signal transmission can be in either
direction.
rtranif1 is the resistive counterpart of tranif1. It is instantiated in an identical manner.
With the above instantiation, if c = 0, s1 and s2 are connected and signal transmission can be in either
direction. If c = 1, the switch is OFF and s1 and s2 are isolated from each other.
rtranif0 is the resistive counterpart of tranif0.
INSTANTIATIONS WITH STRENGTHS AND DELAYS
Propagation delays can be specified for switch primitives on the same lines as was done with the gate
primitives in Chapter 5. For example, an NMOS switch instantiated as
has delay1 as the delay for the output to rise, fall, and turn OFF. The instantiation nmos
has delay_r as the rise-time for the output. delay_f is the fall-time for the output. The turn-off time is
zero. The instantiation
has delay_r as the rise-time for the output. delay_f is the fall-time for the output delay_o is the time to
turn OFF when the control signal ctrl goes from 0 to 1. Delays can be assigned to the other uni-
directional gates (rcmos, pmos, rpmos, cmos, and rcmos) in a similar manner. Bi- directional
switches do not delay transmission – their rise- and fall-times are zero. They can have only turn-on
and turn-off delays associated with them. tran has no delay associated with it.
represents an instantiation with delay0 as the delay for the switch to turn on when control changes
from 0 to 1, with the same delay for it to turn off when control changes from 1 to 0. When a delay
value is not specified in an instantiation, the turn-on and turn-off are considered to be ideal that is,
instantaneous. Delay values similar to the above illustrations can be associated with rtranif1,
tranif0, and rtranif0 as well.
INSTANTIATIONS WITH STRENGTHS AND DELAYS
In the most general form of instantiation, strength values and delay values can be combined.
For example, the instantiation
nmos (strong1, strong0) (delay_r, delay_f, delay_o ) gg (s1, s2, ctrl) ; means the
following:
• It has strength strong0 when in the low state and strength strong1when in the high
state.
• When output changes state from low to high, it has a delay time of delay_r.
• When the output changes state from high to low, it has a delay time of delay_f.
rnmos, pmos, and rpmos switches too can be instantiated in the general form in the same manner. The
general instantiation for the bi-directional gates too can be done similarly.
SYSTEM TASKS, FUNCTIONS, AND COMPILER DIRECTIVES
A number of facilities in Verilog relate to the management of simulation; starting and stopping of simulation,
selectively monitoring the activities, testing the design for timing constraints, etc., are amongst them. Although a
variety of such constructs is available in Verilog.
PARAMETERS
Verilog defines parameter as a constant value that is declared within structure of module. The constant value
signifies timing values, range of variables, wires e.t.c.
The parameter values can be specified and changed to suit the design environment or test environment. Such
changes are effected and frozen at instantiation.
The assigned values cannot change during testing or synthesis.
Timing-Related Parameters
The constructs associated with parameters are discussed here through specific design or test modules.
Example: Module of a half-adderwith delays assigned tothe output transitions; a test bench is also included in
the figure.
module ha_1(s,ca,a,b);
input a,b; output s,ca; xor
#(1,2) (s,a,b);
and #(3,4) (ca,a,b);
endmodule
//test-bench
module tstha;
reg a,b; wire s,ca;
ha_1 hh(s,ca,a,b);
initial
begin
a=0;b=0;
end always
begin
#5 a=1;b=0;
#5 a=0;b=1;
#5 a=1;b=1;
#5 a=0;b=0;
end
initial $monitor($time , " a = %b , b = %b ,out carry = %b , outsum = %b ",a,b,ca,s); initial #30
$stop;
endmodule
Specify Blocks
Module paths are specified and values assigned to their delays through specify blocks. They are used to specify rise time,
fall time, path delays pulse widths, and the like. A “specify” block can have the form shown in Figure
specify
specparam rise_time = 5, fall_time = 6; (a
=>b) = (rise_time, fall_time);
(c => d) = (6, 7);
endspecify
The block starts with the keyword “specify” and ends with the keyword “endspecify”. Specify blocks can appear
anywhere within a module.
Module Paths
Module Path delays are assigned in Verilog within the keywords specify and endspecify. The statements within
these keywords constitute a specify block.
Module paths can be specified in different ways inside a specify block.
Parallel connection
Every path delay statement has a source field and a destination field.
A parallel connection is specified by the symbol => and is used as shown below. Usage: (
<source_field> => <destination_field>) = <delay_value>;
In a parallel connection, each bit in source field connects to its corresponding bit in the destination field.
If the source and the destination fields are vectors, they must have the same number of bits; otherwise, there is a
mismatch. Thus, a parallel connection specifies delays from each bit in source to each bit in destination.
Example: Parallel Connection
(a => out) = 9; //bit-to-bit connection. Both a and out are single-bit
// vector connection. Both a and out are 4-bit vectors a[2:0], out[2:0] a is source field, out is destination field.
// for three bit-to-bit connection statements. (a[0]
=> out[0]) = 9;
(a[1] => out[1]) = 9;
(a[2] => out[2]) = 9;
// Parallel connection
Example
The parameter msb specifies the ALU size –– consistently in the input and the output vectors of the ALU. The size
assignment has been made separately through the assignment statement
parameter msb = 3;
Output Tasks
A number of system tasks are available to output values of variables and selected messages, etc., on the monitor.
Out of these $monitor and $display tasks have been extensively used.
Display Tasks
The $display task, whenever encountered, displays the arguments in the desired format; and the display advances to
a new line.
$strobe Task:
When a variable or a set of variables is sampled and its value displayed, the $strobe task can be used; it senses the value of the
specified variables and displays them.
The $strobe task is executed as the last activity in the concerned time step. It is useful to check for specific activities
and debug modules.
Example:
initial #9 $strobe ("at time %t, di=%b, do=%b", $time, di, do);
$monitor Task:
$monitor task is activated and displays the arguments specified whenever any of the arguments changes.
$stop and $finish Tasks:
The $stop task suspends simulation. The compiled design remains active; simulation can be resumed through commands
available in the simulator.
In contrast $finish stops simulation, closes the simulation environment, and reverts to the operating system.
$random Function:
A set of random number generator functions are available as system functions.
One can start with a seed number (optional) and generate a random number repeatedly. Such random number
sequences can be fruitfully used for testing.
Compiler directives
Compiler directives are special commands, beginning with ‘, that affect the operation of the Verilog simulator.
Time Scale
`timescale specifies the time unit and time precision. A time unit of 10 ns means a time expressed as say #2.3 will have a
delay of 23.0 ns. Time precision specifies how delay values are to be rounded off during simulation. Valid time units
include s, ms, us (µs), ns, ps, fs.
Only 1, 10 or 100 are valid integers for specifying time units or precision. It also determines the displayed time
units in display commands like $display.
Syntax
`timescale time_unit / time_precision;
Examples
`timescale 1 ns/1 ps // unit =1ns, precision=1/1000ns
`timescale 1 ns /100 ps // time unit = 1ns; precision = 1/10ns;
`define
A macro is an identifier that represents a string of text. Macros are defined with the directive `define, and are invoked
with the quoted macro name as shown in the example. Verilog compiliers will substitute the string for the macro
name before starting compilation. Many people prefer to use macros instead ofparameters.
The define directive in Verilog is similar to #define in c-language.
Syntax
`define macro_name text_string;
. . . `macro_name . . .
Example
`define add_lsb a[7:0] + b[7:0]
`define N 8 // Word length
wire [`N -1:0] S;
assign S = 'add_lsb; // assign S = a[7:0] + b[7:0];
Include Directive
Include is used to include the contents of a text file at the point in the current file where the include directive is. The
include directive is similar to the C/C++ include directive.
Syntax
`include file_name;
Example
module x;
`include “dclr.v”; // contents of file “dclr,v” are put here