FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection

June 2015

FUJITSU Storage ETERNUS DX S3 series


Windows 8 iSCSI Single Path Connection
Disclaimer
 The connection information provided in this document is the connection result
that was obtained at Fujitsu Limited's test environment. This does not
guarantee a connection between the Windows 8 used in your environment and
the ETERNUS DX. In addition, this is not a recommendation for using the
ETERNUS DX with Windows 8.
 Fujitsu Limited shall assume no responsibility for any damages as a result of
installing and using the ETERNUS DX with Windows 8 based on the connection
information that is provided in this document.
 Fujitsu Limited does not accept inquiry on or provide support for any Windows
8 issues relating to FUJITSU Storage ETERNUS storage systems. Because of that,
installing and using the ETERNUS DX with Windows 8 is at your own risk.
 The content of this document is subject to change without notice.

System Configuration Notes


 Since an iSCSI LAN handles large amounts of data (traffic volumes) like an FC-
SAN, the iSCSI LAN must have its own switch and be a dedicated LAN that is
separate from the business LANs.
 For IP network security, separate the iSCSI LAN from the management LAN (for
administration).
 The iSCSI LAN must be configured as a dedicated LAN for each path from a
server to the ETERNUS DX.

 ETERNUS DX

FUJITSU Storage ETERNUS DX S3 series

- Firmware version V10L30 or later

- iSCSI port
Type 1G iSCSI

 PC

- Processor Intel® Core™ 2 Duo CPU T7250


@ 2.00 GHz 2.00 GHz
- Installed memory 2.00GB
- System type 32-bit operating system, x64-based processor
- OS Windows 8.1 Enterprise

P3AM-9672-01ENZ0 1 Copyright 2015 FUJITSU LIMITED


FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection
June 2015

 Device Drivers

- Network adapter Marvell Yukon 88E8055


PCI-E Gigabit Ethernet Controller

- Storage controller Microsoft iSCSI initiator

 Test Result

No. Test Item Result


1 Connecting the PC to the ETERNUS DX (with a single path) OK
Configuring the ETERNUS DX (such as the IP addresses for CA
2 OK
ports and other items)
3 Configuring the PC network (IP address) OK
4 Starting the iSCSI service OK
5 Starting the iSCSI initiator OK
6 Configuring the ETERNUS DX (registering PC) OK
7 Configuring the iSCSI initiator OK
Recognizing the ETERNUS DX volume in Disk drives under
8 OK
Device Manager
Recognizing the ETERNUS DX volume after performing a CHAP
9 OK
authentication configuration
Recognizing the ETERNUS DX volume after performing a
10 OK
bidirectional CHAP authentication
11 Assigning a drive to the added volume after formatting OK
12 Writing and deleting to assigned drives OK

P3AM-9672-01ENZ0 2 Copyright 2015 FUJITSU LIMITED


FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection
June 2015

Windows 8 iSCSI Single Path Connection Procedure

 Introduction
This section explains the connection procedure for a Windows 8 iSCSI single path
connection.

The connection procedure is explained with references to the following


Configuration Guides:

- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI)


ETERNUS DX60 S3/DX100 S3/DX200 S3, ETERNUS DX500 S3/DX600 S3,
ETERNUS DX8700 S3/DX8900 S3 Disk storage systems,
ETERNUS DX200F All Flash Array Settings
(herein after referred to as "Server Connection Guide [Storage System Settings]")

- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI)


for Windows®
(herein after referred to as "Server Connection Guide [Windows Settings]")

The connection procedure only describes iSCSI connection (iSCSI initiator)


configuration on the PC.

For the configuration of the target (ETERNUS DX), refer to "Server Connection
Guide (Storage System Settings)".

P3AM-9672-01ENZ0 3 Copyright 2015 FUJITSU LIMITED


FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection
June 2015

 System Diagram
The current connection procedure is verified in the following system configuration:

PC

Windows 8.1 PC

iSCSI initiator

LAN card (iSCSI) LAN card (Public LAN)

192.168.120.130

1Gb LAN HUB

192.168.120.120
Port1 Port1
CA#2 CA#2
CM#0 CM#1

FUJITSU Storage ETERNUS DX S3 series

P3AM-9672-01ENZ0 4 Copyright 2015 FUJITSU LIMITED


FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection
June 2015

 How to Start the Windows 8 iSCSI Initiator


In Windows 8, the iSCSI initiator is installed by default.

 Starting the iSCSI Service

Start the iSCSI service.

For Windows 8, starting the iSCSI initiator starts the iSCSI service.

Procedure

1 Click the upper right part of the [Start] screen. Then in the Charms bar,
search for "iSCSI" using "Search".

2 In the search result, click "Set up iSCSI initiator".

3 Click the [Yes] button to start the iSCSI service.

End of procedure

P3AM-9672-01ENZ0 5 Copyright 2015 FUJITSU LIMITED


FUJITSU Storage ETERNUS DX S3 series Windows 8 iSCSI Single Path Connection
June 2015

 Setting Up the iSCSI Initiator Parameters

Use the iSCSI initiator to set the iSCSI initiator parameters.

For the configuration procedure, refer to "4.7 Setting Up the iSCSI Initiator Driver
Parameters" in "Server Connection Guide (Windows Settings)".

 Setting CHAP Authentication


* The CHAP authentication setting is optional.

For the configuration procedure, refer to "4.8 Setting CHAP Authentication" in


"Server Connection Guide (Windows Settings)".

 Configuring the Operation Related Settings

For the configuration procedure, refer to "Chapter 5 Notes on Operation" in


"Server Connection Guide (Windows Settings)".