Joslyn Clark Controls Index

Table of Contents Description

Vacuum Control Low Voltage, Medium Voltage A


NEMA Control - Heavy Duty TM, 5000 B
NEMA Control - General Duty HP C
Pushbuttons, Selector Switches,
Pilot Devices
Pilot Lights, STAK-LITE D
HP, Pump Controllers Duplex And Triplex Pump Controllers E
Fire Pump Control Electric, Diesel, Residential F
Mill Duty Products Limit Switch, Foot Switches, Palm Switches G
Definite Purpose Control Contactors H
D.C. Control/RHEO Stats 146, 5DP, 7400 J
Relays PM, 447 K
Lighting Contactors Type PM-LC20, LC30, 447, TM-LC L
Photoelectric Sensors MEK90 Series: M
and Control

Replacement Coil Data N


& Reference Pages
0
3
3
All prices in catalog are in U.S. Dollars.

11
Index USAVAC
CV Series Page Number
Low Voltage 200V-1500V
AC Contactors CV4
AC Reversing Contactor CV4
A2
A3, A4
A
AC Starters CV4 A5
Rev Starter CV4 A6
Technical Specifications CV4,5&6 Diagrams & A7, A13, A19
Dimensions
AC Contactors CV5 A8
AC Reversing Contactors CV5 A9, A10
AC Starters CV5 A11
AC Rev Starters CV5 A12
AC Contactor CV6 A14
AC Reversing Contactors CV6 A15, A16
AC Starters CV6 A17
AC Rev Starters CV6 A18
CV Series Starter O/L Heaters A35

VC Series

Low Voltage 200V - 3.6KV


AC Contactors, 200V - 3.6KV A20
AC Contactors (Mechanically Latched) A21
AC Reversing Contactors 200V - 3.6KV A22, A 23
AC Starters 200V - 3.6KV A24
AC Reversing Starters 200V - 3.6KV A25
AC Combination Starters 200V - 1.5KV A26, A27
AC Reduced Voltage Auto Transformer Starters 600V A28
AC Special Purpose Contactors - 200V - 3.6KV, 160-2500 amp. A29
Technical Specifications A30
Dimensions A31-34
AC Vacuum Starters Overload Heaters A35
Parts/Accessories A36
Low Voltage Modifications A37-38

MVC Series
Medium Voltage 2.5 - 7.2KV (Contactors) A39
AC Contactors - 2.5, 5.0, 7.2KV (Mechanically Latched) A40
AC Contactors (Mechanically Interlocked) A41
3
7 AC Special Purpose Contactors - 2.5, 5.0, 7.2KV, 200-3000 amp. A42
5
Technical Specifications A43
Dimensions A44
Medium Voltage Controllers A45
Medium Voltage Modifications A49

A1
AC Vacuum Contactors USAVAC - Low Voltage
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V One Small Size NEMA Size 4 V200
CE IEC 200A
A

600V NEMA Size 4 135A

600Volt Nema Size 4 135A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower Discount
Open Type
Nema Size 4 KW Rating 3 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV77U030406-* $1519.00

660Volt 200AMP Contactor 3 Pole IEC 947-4-1 UL508 CSA 22.2


Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
200A Schedule JC11
1000V 200/208V 220/240V 380/400V 415/440V 460V 500V 575/600V 660-690V Catalog # Price
HP/KW 50/37 75/59 100/75 125/95 150/110 190/140 200/150 250/185 CV77U032006-* $1629.00

1500Volt 200AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating 200A Discount
Nema Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
V200 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 1000V 1500V Catalog # Price
HP/KW 50/37 75/59 125/95 150/110 175/130 300/225 500/370 CV77U031615-* $1693.00
Replacement Parts (Discount Schedule JC80)
Options Discount (Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77-457211A $520
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82 Coil 110/120V 50/60 HZ A77-460915A-1 $248
Aux. Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460915A-2 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460915A-3 $248
Coil 440/480V 50/60 HZ A77-460915A-4 $248
Coil 125V DC A77-460915A-5 $248
Coil 250V DC A77-460915A-6 $248
Control PAK 110/120 50/60 HZ A77-460916A-1 $258
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break
Ordering Information * Coil Table
Voltage Suffix
Use complete catalog number when ordering. 120 AC 76
Engineering Data page A7. 240 AC 26
Replace the (*) with the suffix from the coil table. Renewal Parts page A2. 380 AC 38
460 AC 46
125V DC 125
250V DC 250

A2 Discount Schedule JC11


AC Mechanically Interlocked USAVAC - Low Voltage
Vacuum Contactors Unwired
UL listed to 1500V Three Ratings
CSA Certified to 1500V One Small Size
CE Use for Reversers, Reduced
NEMA Size 4 & V 200 1500V Voltage Auto Transformer, Wye- A
IEC 200A Delta, 2 speed single winding, or 2
speed 2 winding applications

3 Pole Nema Rated ICS-2 UL508 CSA 22.2 Size 4


Mechanically Interlocked Pair Unwired 600V 135A Contactor
Rating Maximum Horsepower/KW Rating 3 Discount
Open Type
Nema Size 4 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV31U030406-*-43 $3520
3 Pole IEC947-4-1 UL508 CSA 22.2
Mechanically Interlocked Pair Unwired 660V 200A
Rating Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
200A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/660V Catalog # Price
HP/KW 50/37 75/59 100/75 150/110 200/150 CV31U032006-*-43 $3740

3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11

1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price

HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV31U031615-*-43 $3980

Options Discount (Schedule JC11) Replacement Parts (Discount Schedule JC80)


Description Catalog # Price
Description Catalog # Price
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82
Interrupter Phase Assembly A77-457211A $520
Aux. Contact Kit 2N/O 2N/C 10A 600V ac AK1 $73
Coil 110/120V 50/60 HZ A77-460915A-1 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5V dc AK3 $220
Coil 220/240V 50/60 HZ A77-460915A-2 $248
Coil 380/415V 50/60 HZ A77-460915A-3 $248
Coil 440/480V 50/60 HZ A77-460915A-4 $248
Plug Stop Jogging Duty Coil 125V DC A77-460915A-5 $248
Nema Coil 250V DC A77-460915A-6 $248
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-1 $258
4 25HP 30HP 50HP 60HP –
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
V200 40HP 60HP 75HP 100HP 125HP
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Voltage Suffix
Engineering Data page A7. 120 AC 76
Replace the (*) with the suffix from the coil table. Renewal Parts page A3. 240 AC 26
380 AC 38
450 AC 46
125V DC 125
250V DC 250

Discount Schedule JC11 A3


AC Reversing Vacuum USAVAC - Low Voltage
Contactors Wired
UL listed to 1500V
Three Ratings
CSA Certified to 1500V
One Small Size
CE
CV Series Nema
A Size 4 & V200
IEC 200A

3 Pole Nema Rated ICS-2 UL508 CSA 22.2 Size 4


Mechanically Interlocked Pair Unwired 600V 135A Contactor
Rating Maximum Horsepower/KW Rating 3 Discount
Open Type
Nema Size 4 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV31U030406-*- $3931
3 Pole IEC947-4-1 UL508 CSA 22.2
Mechanically Interlocked Pair Unwired 660V 200A
Rating Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
200A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/660V Catalog # Price
HP/KW 50/37 75/59 100/75 150/110 200/150 CV31U032006-*- $4355

3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11

1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price

HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV31U031615-*- $4538

Options Discount (Schedule JC11) Replacement Parts (Discount Schedule JC80)


Description Catalog # Price
Description Catalog # Price
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82
Interrupter Phase Assembly A77-457211A $520
Aux. Contact Kit 2N/O 2N/C 10A 600V ac AK1 $73
Coil 110/120V 50/60 HZ A77-460915A-1 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5V dc AK3 $220
Coil 220/240V 50/60 HZ A77-460915A-2 $248
Coil 380/415V 50/60 HZ A77-460915A-3 $248
Coil 440/480V 50/60 HZ A77-460915A-4 $248
Plug Stop Jogging Duty Coil 125V DC A77-460915A-5 $248
Nema Coil 250V DC A77-460915A-6 $248
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-1 $258
4 25HP 30HP 50HP 60HP –
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
V200 40HP 60HP 75HP 100HP 125HP
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Voltage Suffix
Engineering Data page A7. 120 AC 76
Replace the (*) with the suffix from the coil table. Renewal Parts page A4. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

A4 Discount Schedule JC11


USAVAC - Low Voltage AC Vacuum Starters
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V NEMA Size 4 V200A
CE One Small Size IEC 200A
A

600V NEMA Size 4 135A


600Volt Nema Size 4 135A Starter 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Discount
Open Type
Nema Size 4 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV13U030406-* $1674.00
660Volt 200AMP Starter 3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
200A Schedule JC11
660V 200/208V 220/240V 380/400V 415/440V 460V 500V 575/600V 660-690V Catalog # Price
HP/KW 50/37 75/59 100/75 125/95 150/110 190/140 200/150 250/185 CV13U032006-* $2288.00

1500Volt 200 AMP Starter 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V200 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 1000V 1500V Catalog # Price
HP/KW 50/37 75/59 125/95 150/110 175/130 300/225 500/370 CV13U031615-* $2654.00

Replacement Parts (Discount Schedule JC80)


Description Catalog # Price
Options Discount (Schedule JC11) Field Kits
Interrupter Phase Assembly A77-457211A $520
Description Catalog # Price Coil 110/120V 50/60 HZ A77-460915A-1 $248
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82 Coil 220/240V 50/60 HZ A77-460915A-2 $248
Aux. Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 380/415V 50/60 HZ A77-460915A-3 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 440/480V 50/60 HZ A77-460915A-4 $248
Coil 125V DC A77-460915A-5 $248
Coil 250V DC A77-460915A-6 $248
Control PAK 110/120 50/60 HZ A77-460916A-1 $258
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Voltage Suffix
Engineering Data page A7. 120 AC 76
Replace the (*) with the suffix from the coil table. Renewal Parts page A5. 240 AC 26
Order Heaters at $18.00 each from page A35. 380 AC 38
460 AC 46
125V DC 125
250V DC 250

Discount Schedule JC11 A5


USAVAC - Low Voltage AC Vacuum Reversing Starters
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V One Small Size NEMA Size 4
CE CV Series Nema IEC 200A
A Size 4 & V200
IEC 200A

3 Pole Nema Rated ICS-2 UL508 CSA 22.2 Size 4


Mechanically Interlocked Pair Unwired 600V 135A Contactor
Rating Maximum Horsepower/KW Rating 3 Discount
Open Type
Nema Size 4 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV30U030406-*- $4381
3 Pole IEC947-4-1 UL508 CSA 22.2
Mechanically Interlocked Pair Unwired 660V 200A
Rating Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
200A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/660V Catalog # Price
HP/KW 50/37 75/59 100/75 150/110 200/150 CV30U032006-*- $4805

3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11

1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price

HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV30U031615-*- $4988

Options Discount (Schedule JC11) Replacement Parts (Discount Schedule JC80)


Description Catalog # Price
Description Catalog # Price
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82
Interrupter Phase Assembly A77-457211A $520
Aux. Contact Kit 2N/O 2N/C 10A 600V ac AK1 $73
Coil 110/120V 50/60 HZ A77-460915A-1 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5V dc AK3 $220
Coil 220/240V 50/60 HZ A77-460915A-2 $248
Coil 380/415V 50/60 HZ A77-460915A-3 $248
Coil 440/480V 50/60 HZ A77-460915A-4 $248
Plug Stop Jogging Duty Coil 125V DC A77-460915A-5 $248
Nema Coil 250V DC A77-460915A-6 $248
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-1 $258
4 25HP 30HP 50HP 60HP –
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
V200 40HP 60HP 75HP 100HP 125HP
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Voltage Suffix
Use complete catalog number when ordering. Engineering Data page A7. 120 AC 76
Replace the (*) with the suffix from the coil table. Renewal Parts page A6. 240 AC 26
380 AC 38
Order Heaters at $18.00 each from page A35. 450 AC 46
125V DC 125
250V DC 250

A6 Discount Schedule JC11


AC Vacuum Contactors Engineering Data
Technical Specifications CV Series
Description NEMA Size 4 600V 200 Amp 1000V 200 Amp 1500V
Motor HP/KW AC3
Cat # CV 77U030406-* CV 77U032006-* CV 77U031615-*
NEMA 1CS9-2 1500V
Voltage 150A
208
200A
50/37
A
Standard NEMA 1CS-2 IEC 947-4-1 IEC 947-4-1 1000V 40/30
220/240 50/37 75/59
UL508 CSA22.2 UL508 CSA22.2 UL508 CSA22.2 1500V
380/400 ---- 100/75
Power Ratings
415/440 ---- 125/93
Insul. & Operating Volt 600 Volts 1000 Volts 1500 Volts 460
Rated Oper. AC1 150 Amps 200 Amps 200 Amps
100/75 150/110
500 ---- 190/140
Rated Oper. AC3 100 HP 460/575V 250 HP 185KW-660V 500 HP 370KW-1500V
575/600 100/75 200/150
Rated Oper. AC4 60 HP 460/575V 175 HP-130KW-660V 315 HP-235KW-1500V
660/690 ---- 250/185
Rated Frequency 50 - 400 Hz
1000 ---- 300/225
Making Current 2000 Amps 1500 ---- 500/370
Breaking Current 1600 Amps Three Phase Transformer Load KVA
Dielectric Strength 6Kv - 1 Min. Voltage 150A 200A
Interupting Current 2.2 KA 208 54 72
Short Time Current 1 Sec. 5000 A 220/240 57 55
Short Time Current 10 Sec 1600 A 380/400 99 135
Mechanical Life 1.2 X 106 415/440 108 152
Elect. Life AC3 Duty 1 X 106
460/500 119 173
Switching Frequency 600 / Hour (1 Every 6 Sec) 575/600 130 207
660 171 225
Withstand Current 10KA50MSec
1000 260 346
Chop Current Max 0.9 A 1500 390 519
Operating Range -15% + 10% - at Range Voltage Three Phase Capacitor Load KVAR
Inrush Power VA 1200VA 20 ms Duration Voltage 150A 200A
Holding Power VA 12 VA 208 40 54
Opening Time MS 120ms 220/240 43 62
Closing Time MS 20-40ms 380/400 74 104
Pick-Up Voltage 80% Cold 85% Hot or less 415/440 81 114
Drop-Out Voltage 70% or less 460 90 127
575/600 115 156
Recommended CPT 400VA Machine Tool Transformer 5% Regulation at 20%pf
1000 195 260
Applications Ratings
1500 292 390
Mounting Installation All Planes (Contactor only)
Altitude 6600 ft. 2000 Meters Options
Ambient Storage -65oF (-54oC) +160oF (71oC)
Operating -40oF (-40oC) +135
105oF (57
41oC)
Vibration / Shock 40Hz - 2G. / 30G. Lug Kit 2/0 250mcm Cat.# KVC4-2
Weight 13 lbs. 5.9Kg. Auxilliary Contact Kits

2NO. 2NC 600V. 10A ac. Cat.# AK1


2NO. 2NC 5V.10mA dc. Cat.# AK3
Only 1 Kit can be added for total
of 3 N/O 3 N/C contacts

Coils

Description Hz. Cat.Suffix


110/120V 50/60Hz. -76
220/240V 50/60Hz. -26
380/415V 50/60Hz. -38
440/480V 50/60Hz. -46
125V dc -125
250V dc -250

*WIDTH DIMENSION FOR CV


DC COIL DESIGNS & ALL
CVC COIL DESIGNS

For 250V dc contact 21/22 is


Late Break N/C in series with 'm' late break

A7
USAVAC - Low Voltage AC Vacuum Contactors
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V One Small Size NEMA Size 5
CE IEC 400A
A

600V NEMA Size 5 270A 1000V 400A


600Volt Nema Size 5 270A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV77U030506-* $1940.00

1000Volt 400AMP Contactor 3 Pole IEC 947-4-1 UL508 CSA 22.2


Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV77U034A06-* $2122.00

1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)

Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV77U034A15-* $2242.00
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV77U033A15-* $2242.00

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A460880A-1 $650
Lug Kit 3 Per Kit #4-500 mcm KVC5-1 $ 90 A77-460930A-1
Coil 110/120V 50/60 HZ $284
Lug Kit 3 Per Kit (2) #6-300 mcm KVC5-2 $100
Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 A77-460930A-3 $284
Coil 380/415V 50/60 HZ
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-5 $284
Coil 250V DC A77-460930A-6 $284
Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Control PAK 220/240 50/60 HZ A77-460916A-5 $258
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A13. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC 76
Renewal Parts page A8. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

A8 Discount Schedule JC11


AC Mechanically Interlocked USAVAC - Low Voltage
Vacuum Contactors Unwired
UL listed to 1500V Three Ratings
CSA Certified to 1500V One Small Size
CE Use for Reversers, Reduced
NEMA Size 5 & V320 Voltage Auto Transformer Starters, A
IEC 400A Wye-Delta, 2 speed single winding,
starter applications

600Volt Nema Size 5 270A Mechanically Interlocked Pair Unwired 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV31U030506-*-43 $5984.00

1000Volt 400AMP Mechanically Interlocked Pair Unwired 3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV31U034A06-*-43 $6606.00
1500V 400AMP Mechanically Interlocked Pair Unwired 3 Pole IEC 947-4-1 (1000V) UL508 (1500V)
CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV31U034A15-*-43 $6972.00
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV31U03A15-*-43 $6972.00

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A460880A-1 $650
Lug Kit 3 Per Kit #4-500 mcm KVC5-1 $ 90 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Lug Kit 3 Per Kit (2) #6-300 mcm KVC5-2 $100 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-5 $284
Plug Stop Jogging Duty
Coil 250V DC A77-460930A-6 $284
Nema Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Size 200V 230V 400V 460V 575V
5 50HP 60HP 100HP 120HP –
Control PAK 220/240 50/60 HZ A77-460916A-5 $258
V320 75HP 100HP 150HP 175HP 200HP Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A13. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC 76
Renewal Parts page A9. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

Discount Schedule JC11 A9


AC Mechanically Interlocked USAVAC - Low Voltage
Vacuum Contactors Wired
CE Three Ratings
NEMA Size 5 & V320 One Small Size
IEC 400A Use for Reversers, Reduced
A Voltage Auto Transformer Starters,
Wye-Delta, 2 speed single winding,
starter applications

600Volt Nema Size 5 270A Contactor Mechanically Interlocked Pair Wired


3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV31U030506-* $6719.00
1000Volt 400AMP Contactor Mechanically Interlocked Pair Wired
3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV31U034A06-* $7283.00
1500V 400AMP Contactor Mechanically Interlocked Pair Wired
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV31U034A15-* $7540.00
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV31U033A15-* $7540.00

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A460880A-1 $650
Lug Kit 3 Per Kit #4-500 mcm KVC5-1 $ 90 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Lug Kit 3 Per Kit (2) #6-300 mcm KVC5-2 $100
Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 A77-460930A-3 $284
Coil 380/415V 50/60 HZ
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-5 $284
Plug Stop Jogging Duty
Coil 250V DC A77-460930A-6 $284
Nema Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Size 200V 230V 400V 460V 575V
5 50HP 60HP 100HP 120HP –
Control PAK 220/240 50/60 HZ A77-460916A-5 $258
V320 75HP 100HP 150HP 175HP 200HP Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A13. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC 76
Renewal Parts page A10. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

A10 Discount Schedule JC11


USAVAC - Low Voltage AC Vacuum Starters
UL listed to 1500V Three Ratings CVC Series
CSA Certified to 1500V One Small Size NEMA Size 5 V320
CE IEC 400A
A

600V NEMA Size 5 270A

600Volt Nema Size 5 270A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200/208V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV13U030506-* $2699

1000Volt 400AMP Contactor 3 Pole IEC 947-4-1 UL508 CSA 22.2


Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV13U034A06-* $2882

1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)

Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 380/415V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV13U034A15-* $3202
Nema V320 100/75 150/112 250/187 300/220 300/220 - 500/370 900/670 CV13U033A15-* $3202

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A460880A-1 $650
Lug Kit 3 Per Kit #4-500 mcm KVC5-1 $ 90 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Lug Kit 3 Per Kit (2) #6-300 mcm KVC5-2 $100 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-5 $284
Coil 250V DC A77-460930A-6 $284
Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Control PAK 220/240 50/60 HZ A77-460916A-5 $258
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A13. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC 76
Order Heaters at $18.00 each from page 35. Renewal Parts page A11. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

Discount Schedule JC11 A11


USA VAC AC Reversing Starters
Low Voltage
Three Ratings
NEMA Size 5 & V 320 One Small Size
IEC 400A Use for Reversers, Reduced
A Voltage Auto Transformer Starters,
Wye-Delta, 2 speed single winding,
starter applications

3 Pole Nema ICS-2 UL508 CSA 22.2 Size 5 Reversing Starter 600V 270 AMP
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV30U030506-* $7269

3 Pole IEC 947-4-4 UL508 CSA 22.2 Reversing Starter 660V 400 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV30U034A06-* $7833

3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V) 400A

Rating 400A Discount


Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V320 Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV30U034A15-* $8090
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV30U033A15-* $8090

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price
Interrupter Phase Assembly A460880A-1 $650
Lug Kit 3 Per Kit #4-500 mcm KVC5-1 $ 90
Coil 110/120V 50/60 HZ A77-460930A-1 $284
Lug Kit 3 Per Kit (2) #6-300 mcm KVC5-2 $100
Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73
Coil 380/415V 50/60 HZ A77-460930A-3 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 A77-460930A-4 $284
Coil 440/480V 50/60 HZ
Coil 125V DC A77-460930A-5 $284
Plug Stop Jogging Duty
Coil 250V DC A77-460930A-6 $284
Nema Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Size 200V 230V 400V 460V 575V
Control PAK 220/240 50/60 HZ A77-460916A-5 $258
5 50HP 60HP 100HP 120HP –
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
V320 75HP 100HP 150HP 175HP 200HP
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A13. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC 76
Order Heaters at $18.00 each from page A35 Renewal Parts page A12. 240 AC 26
380 AC 38
460 AC 46
125V DC 125
250V DC 250

A12 Discount Schedule JC11


AC Vacuum Contactors Engineering Data
Technical Specifications CV Series Power Rating

Description
Cat #
NEMA Size 5 600V
CV77U030506-*
400 Amp 1000V
CV77U034A06-*
400 Amp 1500V
CV77U034A15-*
Motor HP/KW AC3 A
Voltage 270A 400A
Standard NEMA ICS-2 IEC 947-4-1 1000V IEC 947-4-1 1000V
208 75/56 100/75
UL508 CSA22.2 UL508 CSA22.2 NEMA ICS-2.9 1500V
220/240 100/75 150/112
UL508 CSA22.2 1500V 380/415 ---- 250/187
Power Ratings 460 200/150 300/220
Insul. & Operating Volt 600 Volts 1000 Volts 1500 Volts 575/600 200/150 400/300
Rated Oper. AC1 270 Amps 400 Amps 400 Amps 660/690 ---- 450/336
Rated Oper. AC3 200 HP 460/575V 500 HP-370KW-660V 850 HP-650KW-1500V 1000 ---- 700/520
Rated Oper. AC4 120 HP 460/575V 300 HP-260KW-660V 650 HP-570KW-1500V 1500 ---- 850/650
Rated Frequency 50 - 400 Hz
Making Current 4000 Amps Three Phase Transformer Load KVA
Breaking Current 3200 Amps Voltage 270A 400A
Dielectric Strength 6Kv - 1 Min. Interruptor Gap 208 108 144
Interrupting Current 4.6 KA 220/240 114 110
Short Time Current1 Sec. 7000 A 380/400 198 270
Short Time Current 10 Sec. 3200 A 415/440 216 304
Mechanical Life
460/500 238 346
1.2 X 106
575/600 260 414
Elect. Life AC3 Duty 1 X 106
660 342 450
Switching Frequency v600/ Hour 1 Every 6 Sec
1000 520 692
Withstand Current 18KA 50 MS 1500 780 1038
Chop Current Max 0.9 A Three Phase Capacitor Load KVAR
Operating Range -15% + 10% - over Range Voltage Voltage 270A 400A
Inrush Power VA 1100VA 120 ms Duration 208 80 108
Holding Power VA 10-12 VA 220/240 86 124
Opening Time MS 160ms 380/400 148 208
Closing Time MS 20-40ms 415/440 162 228
Pick-Up Voltage 80% Cold 85% Hot or less 460 180 254
575/600 230 312
Drop-Out Voltage 70% or less
1000 390 520
Recommended CPT 400VA Machine Tool Transformer 5% Regulation at 20%pf 1500 584 780
Applications Ratings
Mounting Installation All Planes Contactor Only
Altitude 6600 ft. 2000 Meters
Options
Ambient Storage -65oF (-54oC) +160oF (71oC)
Operating o o o
105 F(41
-40 F (-40 C) +135 o
(57 C)
Vibration / Shock 40Hz - 2G. / 30G.
Lug Kit 2#6-300mcm Cat.# KVC5-2
Weight 26 lbs. 11.8 Kg. Auxilliary Contact Kits

Dimensions 2NO.2 NC 600V.10A ac. Cat.# AK1


2NO.2 NC 5V.10mA dc. Cat.# AK3
Only 1 Kit can be added for total
of 3 N/O 3 N/C contacts

Coils

Description Hz. Cat. Suffix


110/120V 50/60Hz. -76
220/240V 50/60Hz. -26
380/415 50/60Hz. -38
440/480 50/60Hz. -46
125 DC -125
250DC -250

For 250V dc contact 21/22 is


Late Break N/C in series with 'm' late break DEPTH OF CONTACTOR 6.46" (164mm)

A13
AC Vacuum Contactors USAVAC - Low Voltage
UL listed to 1500V Three Ratings CVC Series
CSA Certified to 1500V One Small Size NEMA Size 6
CE NEMA V600
A IEC 600A

600V NEMA Size 6 540A 1000V 600A

600Volt Nema Size 6 540A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 6 HP/KW Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV77U030606-* $3203

1000Volt 400AMP Contactor 3 Pole IEC 947-4-1 UL508 CSA 22.2


Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A 1000V Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/4500 650/485 CV77U036A06-* $3386

1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)

Rating 600A Discount


Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V600 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 250/150 200/150 250/187 400/300 600/450 650/485 1000/750 1200/900 CV77U036A15-* $3523
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200 CV77U036V15-* $3523
Replacement Parts (Discount Schedule JC80)
Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-7 $284
Coil 250V DC A77-460930A-8 $284
Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Control PAK 110/120 50/60 HZ A77-460916A-5 $258
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A19 Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Renewal Parts page A14. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250

A14 Discount Schedule JC11


AC Mechanically Interlocked
USAVAC - Low Voltage Vacuum Contactors Unwired
• CE • Three Ratings
• NEMA Size 6 & V600 • One Small Size
• Use for Reversing, Reduced
• IEC 600A
Voltage Auto Transformer, Wye- A
Delta, 2 speed single winding, or 2
speed 2 winding applications

3 Pole Nema Rated ICS-2 UL508 CSA 22.2


Mechanically Interlocked Pair Unwired 600V Size 6 540 AMP
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 6 HP/KW Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV31U030606-*-43 $11968

3 Pole IEC 947-4-1 UL508 CSA 22.2 Mechanically Interlocked Pair Unwired 1000 Volt 600 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A 1000V Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 CV31U036A06-*-43 $13212
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Mechanically Interlocked Pair Unwired 1.5 KV 60AMP
Rating 600A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V600 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 1000/750 1200/900 CV31U036A15-*-43 $13432
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200CV31U036V15-*-43 $13432

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-7 $284
Plug Stop Jogging Duty
Coil 250V DC A77-460930A-8 $284
Nema Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Size 200V 230V 400V 460V 575V
6 100HP 120HP 200HP 240HP –
Control PAK 110/120 50/60 HZ A77-460916A-5 $258
V600 150HP 150HP 300HP 375HP 450HP Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A19 Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Renewal Parts page A15. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250

Discount Schedule JC11 A15


AC Mechanically Interlocked Wired
USAVAC - Low Voltage Vacuum Contactors
• CE • Three Ratings
• NEMA Size 6 & V600 • One Small Size
• IEC 600A • Use for Reversing, Reduced
A Voltage Auto Transformer, Wye-
Delta, 2 speed single winding, or 2
speed 2 winding applications

3 Pole Nema Rated ICS-2 UL508 CSA 22.2


Mechanically Interlocked Pair Unwired 600V Size 6 540 AMP
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 6 HP/KW Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV31U030606-*- $16052.00

3 Pole IEC 947-4-1 UL508 CSA 22.2 Mechanically Interlocked Pair Unwired 1000 Volt 600 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A V600 Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 CV31U036A06-*- $16562.00
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Mechanically Interlocked Pair Unwired 1.5 KV 600AMP
Rating 600A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema 1000V Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 1000/750 1200/900 CV31U036A15-*- $17477.00
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200 CV31U036V15-*- $17477.00

Replacement Parts (Discount Schedule JC80)


Options (Discount Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Plug Stop Jogging Duty Coil 125V DC A77-460930A-7 $284
Nema Coil 250V DC A77-460930A-8 $284
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-4 $258
6 100HP 120HP 200HP 240HP – Control PAK 110/120 50/60 HZ A77-460916A-5 $258
V600 150HP 150HP 300HP 375HP 450HP Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break
Ordering Information * Coil Table
Use complete catalog number when ordering. Engineering Data page A19 Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Renewal Parts page A16. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250

A16
USA VAC AC Starters
Low Voltage
CE • Three Ratings CV Series
NEMA Size 6 & V 600 • One Small Size NEMA Size 6
IEC 600A IEC 600A
A

600Volt Nema Size 6 540A Starter 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating Discount
3 Phase HP/KW Open Type
Nema Size 6 Schedule JC11
600V 200/208V 2500V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV13U030606-* $3898

1000Volt 400AMP Contactor 3 Pole IEC 947-4-1 UL508 CSA 22.2


Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A 1000V Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/4500 650/485 CV13U036A06-* $4081

1500 Volt 600 AMP Starter 3 Pole ICS 2-9 IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)

Rating 600A Discount


Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V600 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650-485 1000/750 1200/900 CV13U036A15-* $4483
Nema V600 200/150 200/150 375/280 500/350 600/470 1100/820 1600/1200 CV13U036V15-* $4483
Replacement Parts (Discount Schedule JC80)
Options (Discount Schedule JC11) Field Kits Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Coil 125V DC A77-460930A-7 $284
Coil 250V DC A77-460930A-8 $284
Control PAK 110/120 50/60 HZ A77-460916A-4 $258
Control PAK 110/120 50/60 HZ A77-460916A-5 $258
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break

Ordering Information * Coil Table


Use complete catalog number when ordering. Engineering Data page A19. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Order Heaters at $18.00 each from page A35 Renewal Parts page A17. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250

Discount Schedule JC11 A17


USA VAC AC Reversing Starters
Low Voltage
• NEMA Size 6 & V600 • Three Ratings
• IEC 600A • One Small Size
A • Use on Reversers Reduced Voltage
Auto Transformers,
Wye-Delta & 2 speed
single or double winding starter
applications.

600Volt Nema Size 6 540A Starter 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating Discount
3 Phase HP/KW Open Type
Nema Size 6 Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/200 CV30U030606-* $16602

1000Volt 600A Reversing Starter 3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A Schedule JC11
660V 200/208V 220/240V 380/400V 415/440V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 450/330 400/300 600/450 650/485 CV30U036A06-* $17112

1500 Volt 600 AMP Starter 3 Pole ICS 2-9 IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)

Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 375/280 400/300 600/450 650/485 1000/750 1200/900 CV30U036A15-* $18027
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200 CV30U036V15-* $18027
Replacement Parts (Discount Schedule JC80)
Options (Discount Schedule JC11) Field Kits Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Plug Stop Jogging Duty Coil 125V DC A77-460930A-7 $284
Nema Coil 250V DC A77-460930A-8 $284
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-4 $258
6 100HP 120HP 200HP 240HP –
Control PAK 110/120 50/60 HZ A77-460916A-5 $258
V600 150HP 150HP 300HP 375HP 450HP
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break
Ordering Information * Coil Table
Use complete catalog number when ordering. Engineering Data page A19. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Order Heaters at $18.00 each from page A35 Renewal Parts page A18. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250

A18 Discount Schedule JC11


Contactors & Starters Engineering Data
Technical Specifications CVC Series
Power Rating
Description NEMA Size 6 600V 600 Amp 1000V 600 Amp 1500V
Motor HP/KW AC3
Cat # CV 77U030606-* CV 77U036A06-* CVC 77U036A15-*
Standard NEMA 1CS-2 IEC 947-4-1
NEMA 1CS-2-9
IEC 947-4-1 1000V
NEMA 1CS-2-9
Voltage
208
540A
150/112
600A
200/150
A
UL508 CSA22.2
UL508 CSA22.2 UL508 CSA22.2 1500V 220/240 200/150 200/150
Power Ratings 400 ---- 250/187
Insul. & Operating Volt 600 Volts 1000 Volts 1500 Volts 460 400/300 500/350
Rated Oper. AC1 540 Amps 600 Amps 600 Amps 575/600 400/300 600/450
Rated Oper. AC3 400 HP 460/575V 750 HP-550KW-660V 1200 HP-900KW-1500V 660/690 ---- 650/485
Rated Oper. AC4 250 HP 460/575V 525 HP-390KW-660V 950 HP-700KW51500V 1000 ---- 1000/750
Rated Frequency 50 - 400 Hz 1500 ---- 1200/900
Making Current 6000 Amps Three Phase Transformer Load KVA
Breaking Current 4800 Amps Voltage 540A 600A
Dielectric Strength 6Kv - 1 Min. Interruptor Gap 208 194 216
Interupting Current 6 KA
220/240 224 249
Short Time Current 1 Sec. 380/400 396 415
9000 A
415/440 432 450
Short Time Current 10 Sec. 4800 A
460/500 476 519
Mechanical Life .75 X 106 575/600 520 620
Elect. Life AC3 Duty .5 X 106 660 617 685
Switching Frequency 300 / Hour 1 Every 12 Sec. 1000 1040 1384
Withstand Current 30KA 50MS 1500 1560 2076
Chop Current Max 0.9 A Three Phase Capacitor Load KVAR
Operating Range -15% + 10% - over Range Voltage Voltage 540A 600A
Inrush Power VA 1600VA 120 msec Duration 208 160 173
Holding Power VA 10-12.5VA 220/240 172 200
Opening Time MS 160ms 380/400 296 332
415/440 324 366
Closing Time MS 20-40 msec
460 360 382
Pick-Up Voltage 80% Cold 85% Hot or less
575/600 460 500
Drop-Out Voltage 70% or less 1000 780 830
Recommended CPT 400VA Machine Tool Transformer 5% Regulation at 20%pf 1500 1168 1250
Applications Ratings
Mounting Installation All Planes contactor only
Altitude 6600 ft. 2000 Meters
Options
Ambient Storage -65oF (-54oC) +160oF (71oC)
Operating -40oF (-40oC) +135
105oF (57
41oC)
Vibration / Shock 40Hz - 2G. / 30G. Lug Kit 2 #2-600mcm Cat.# KVC6-2
Weight 28 lbs. 12.7 Kg. Auxilliary Contact Kits

2NO.2 NC 600V.10A ac. Cat.# AK1


Diagram Dimensions 2NO.2 NC 5V.10mA dc. Cat.# AK3
Only 1 Kit can be added for total
of 3 N/O 3 N/C contacts

Coils

Description Hz. Cat. Suffix


110/120V 50/60Hz. -76
220/240V 50/60Hz. -26
380/415 50/60Hz. -38
440/480 50/60Hz. -46
125 DC -125
250DC -250

For 250V dc contact 21/22 is DEPTH OF CONTACTOR 6.46" (164mm)


Late Break N/C in series with 'm' late break

A19
USAVAC - Low Voltage AC Vacuum Contactors
5
UL Listed to 1500V
5 Electrically Held AC or DC Coils
CSA Certified to 1500V
UL/CSA recognized to 3600V
A

3 Pole, 320A, 1500V 3 Pole, 600A, 1500V 3 Pole, 700A, 600V 3 Pole, 1000A, 1500V

Contactors 200V-1500V - Bulletin 7707


Ampere Maximum Horsepower Ratings - 3 Phase Open Type
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price
3 Pole
160 3 50 60 100 125 150 300 420 4 VC77U03415 - * $ 1693.
3
320 100 125 200 250 300 600 830 5 VC77U03515 - * 2150.
600 1 200 200 375 500 575 1200 1600 6 VC77U03615 - * 4301.
6
700 225 300 500 550 700 ----- ----- --- VC77U037A06 -* 5948.
1000 1, 2 ----- ----- ----- ----- ----- ----- ----- SVC77U031015 -* 8967.
2 Pole
160 ----- ----- ----- ----- ----- ----- 4 VC77U02415 - * 1510.
320 ----- ----- ----- ----- ----- ----- 5 VC77U02515 - * 1876.
1
600 ----- ----- ----- ----- ----- ----- 6 VC77U02615 - * 3752.
1
1000 ----- ----- ----- ----- ----- ----- SVC77U021015 - * 10138.

Contactors 1501V-3600V - Bulletin 7707


Ampere Maximum Horsepower Rating - 3 Phase Open Type
Rating 2300V 3300V Catalog No. Price
3 Pole
160 4
600 960 VC77U03436 - * $ 2141.
320 4 1250 1920 VC77U03536 - * 2269.
600 1, 3 2400 3700 VC77U03636 - * 5417.
1, 3 SVC77U031036 - * 12444.
1000 ----- -----
2 Pole
160 ----- ----- VC77U02436 - * 1757.
320 ----- ----- VC77U02536 - * 2105.
Note: 1.Two 320 ampere contactors connected in parallel for 600A,
Mechanically Interlocked Contactors on page A22
three in parallel for 1000A.
and A23 should be used if short circuit current can
2.Motor applications limited to 1000 ampere continuous and
flow when switching between two or more
LRC 6KA maximum.
contactors.
3.Terminal boots provided on center phase.
For KW Rating Multiply HP Ratings
4.Terminal boots provided on all phases.
by .746 (example: 100HP x .746 = 75KW)
5.160, 320, 600A 3 pole contactors UL listed and CSA certified.
6. UR recognition 600V
Ordering Information Coil Table
Use complete catalog number when ordering. Engineering Data page A30. Voltage AC Suffix Voltage DC Suffix
Replace the (*) with the suffix from the coil table. Renewal Parts page A36. 120 - 76 125 -125
240 - 26 250 -250

A20 Discount Schedule JC11


Low & Medium Voltage - USAVAC AC Latched Vacuum Contactors
3
UL Listed to 1500V
3 Mechanically Latched AC & DC Close And
CSA Certified to 1500V
Trip Coils
UL/CSA to 3600V
A

3 Pole, 320A, 1500V 3 Pole, 600A, 1500V 3 Pole, 700A, 600V

Contactors 200V-1500V - Bulletin 7707


Ampere Maximum Horsepower Ratings - 3 Phase Type
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price
3 Pole
1
160 50 60 100 125 150 300 420 4 VCL77U03415 - * $ 2516.
1
320 100 125 200 250 300 600 830 5 VCL77U03515- * 2974.
600 1 200 200 375 550 575 1200 1600 6 VCL77U03615- * 5124.
700 4 225 300 500 550 700 ------ ------ VCL77U037A06-* 6863.
2 Pole
160 ----- ----- ----- ----- ----- ----- ----- 4 VCL77U02415 - 2333.
320 ----- ----- ----- ----- ----- ----- ----- 5 VCL77U02515- 2699.

Contactors 1501V-3600V - Bulletin 7707


Ampere Maximum Horsepower Rating - 3 Phase Open Type
Rating 2300V 3300V Catalog No. Price
3 Pole
2 $ 2695.
160 600 960 VCL77U03436 - *
320 2 1250 1920 VCL77U03536 - * 3093.
2 Pole
160 ----- ----- VCL77U02436 - * 2580.
320 ----- ----- VCL77U02536 - * 2928.

Mechanically Interlocked Contactors on page A22


and A23 should be used if short circuit current can
Note: 1.Terminal boots provided on center phase. flow when switching between two or more
2.Terminal boots provided on all phases.
contactors.
3.160, 320A 3 pole contactors UL listed and CSA certified. For KW Rating Multiply HP Ratings
4.UR recognition 600V by .746 (example: 100HP x .746 = 75KW)

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage AC Suffix Voltage DC Suffix
Replace the (*) with the suffix from the coil table. Modification Data page A37. 120 - 76 125 -125
EXAMPLE: VCL77UO3515-76-125 Renewal Parts page A36.
240 - 26 250 -250
(120VAC Close Coil 125VDC Trip Coil)

Discount Schedule JC11 A21


AC Mechanically Interlocked
Low & Medium Voltage - USAVAC Vacuum Contactors Unwired

One 3 Pole, One 5 Pole, 320A Contactor Two 3 Pole, 320A Contactors

USAVAC Vacuum Contactors mechanically interlocked suitable for use in reversing, Wye-Delta,
reduced voltage auto transformer, and 2 speed single or two winding starters.

Mechanically Interlocked Unwired, 200V-1500V - Bulletin 7707


Ampere Maximum Horsepower Ratings - 3 Phase Open Type
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price
3 Pole - 3 Pole
3
160 50 60 100 125 150 300 420 160/160 VC31U03415 - * - 43 2 $ 4987.
320 3 100 125 200 250 300 600 850 320/320 VC31U03515 - * - 43 2 5847.
600 200 200 375 500 575 1200 1600 600/600 VC31U03615 - * - 43 2 12096.
3
320 100 125 200 250 300 600 850 320/160 VC82U03515 - * - 43 2 5481.
2 9059.
600 200 200 375 500 575 1200 1600 600/320 VC82U03615 - * - 43
1
3 Pole - 5 Pole
3 2
160 50 60 100 125 150 300 420 160/160 VC50U04C215 - * - 43 7595.
3 2
320 100 120 200 250 300 600 830 320/320 VC50U05C215 - * - 43 9333.

For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)

Mechanically Interlocked Unwired, 1501V-3600V - Bulletin 7707


Ampere Maximum Horsepower Rating - 3 Phase Open Type 2
Rating 2300V 3300V Catalog No. Price
3 Pole - 3 Pole
160 4
600 960 VC31U03436 - * - 43 2 $ 5444.
4 2
320 1250 1920 VC31U03536 - * - 43 6350.
600 3
2400 3700 VC31U03636 - * - 43 2 13322.
1
3 Pole - 5 Pole
4 2
160 600 960 VC50U04C236 -* - 43 8418.
320 4
1250 1920 VC50U05C236 -* - 43 2 . 10157.

Note:
1. To be used for 2 speed single winding applications only. 3. Terminal boots provided on center phase.
2. Modification 43 in the catalog number suffix means power 4. Terminal boots provided on all phases.
wiring between contactors not included.

Ordering Information Coil Table


Use complete catalog number when ordering. Replace Engineering Data page A30. Voltage Suffix
the (*) with the suffix from the coil table. Modification Data page A37. 120 - 76
Renewal Parts page A36. 240 - 26

A22 Discount Schedule JC11


USAVAC - Low & Medium Voltage AC Reversing Contactors

250 HP 460V Jog Duty Reverser with M.O.V. Suppressors 300 HP 575V Reverser

3 Pole AC Reversing Contactors, 200V-1500V - Bulletin 6031


1
Open Type 1500V Open Type 600V
Maximum Horsepower Ratings - 3 Phase
Ampere Standard Duty Jogging Duty
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price Catalog No. Price

160 50 60 100 125 150 300 420 4 VC31U03415 - * $ 7302. VJ31U03406 - * $ 7979.
320 100 125 200 250 300 600 850 5 VC31U03515 - * 8144. VJ31U03506 - * 8748.
600 200 200 375 500 575 1200 1600 6 VC31U03615 - * 16452. VJ31U03606 - * 17129.

3 Pole AC Reversing Contactors, 1501V-3600V - Bulletin 6031


Open Type 3600V
Maximum Horsepower Ratings - 3 Phase
Ampere Standard Duty
2
Rating 2300V 3300V Catalog No. Price
160 600 960 VC31U03436 - * $ 7668.
320 1250 1920 VC31U03536 - * 8583.

Note:
1. To be used when application involves plugging & inching (e.g. crane control). M.O.V. suppressor included on
power circuit. For other voltages consult factory.
2. Terminal boots provided on center phase.

For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil table. Renewal Parts page A36. 120 - 76
240 - 26

Discount Schedule JC11 A23


Low Voltage - USAVAC Dimensions

USAVAC - Low & Medium Voltage AC Starters


UL listed to 1500V
CSA Certified to 1500V
A

Open Type Open Type


250HP 460V 250 HP, 460V Non Combination 500HP 460V
850 HP 1500V Starter in Type 1 Enclosure 1600 HP1500V

3 Pole AC Vacuum Starters, 200V-1500V - Bulletin 6013


Amp. Maximum Horsepower Ratings - 3 Phase NEMA Type 121 NEMA Type11 Open Type1
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price Catalog No. Price Catalog No. Price
135 40 50 75 100 125 ------ ------ 4 VS13TA3406- * $ 3312. VS13AA3406- * $ 2763. VS13U03406-* $2223.
160 50 60 100 125 150 300 420 4 VS13TA3E15- * 4410. VS13AA3E15- * 4044. VS13U03E15-* 3495.
320 100 125 200 250 300 600 850 5 VS13TA3515- * 4557. VS13AA3515- * 4191. VS13U03515- * 3642.
2
600 200 200 375 500 575 1200 1600 6 VS13TA3615- * 8747. VS13AA3615- * 8400. VS13U03615- * 7302.
For NEMA 3R use NEMA 12 price and change 5th character in catalog number to "R".
For Latched Starters refer to Note (6) on page "A5" for Ordering Information.
For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)

Ampere Maximum Horsepower Ratings - 3 Phase Open Type 1


Rating 2300V 3300V Catalog No. Price
4
160 600 960 VS13U03436 - * $ 4566.
320 4 1250 1920 VS13U03536 - * 5472.
600 2, 3 2400 3700 VS13U03636 - * 10943.

Note:
1. Three overload heaters are required see page A26 3. Terminal boots provided on center phase.
2. Two 320 ampere contactors connected in parallel for 600A. 4. Terminal boots provided on all phases.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil table. Modification Data page A37. 120 - 76
Order Heaters at $18.00 each from page A35. Renewal Parts page A36. 240 - 26

A24 Discount Schedule JC11


AC Reversing Starters Low & Medium Voltage - USAVAC

460V 250 HP Reversing Starter Suitable for Crane Control

3 Pole Wired Reversing Starters, 200V-1500V - Bulletin 6030


Open Type 1500V 1 Open Type 600V 1,2
Maximum Horsepower Ratings - 3 Phase
Ampere Standard Duty Jogging Duty
Rating 200/208V 230V 380V 460V 575V 1000V 1500V Size Catalog No. Price Catalog No. Price
135 40 50 75 100 125 ---- ---- 4 VS30U03406 - * $ 7549. VJ30U03406 - * $ 7869
160 50 60 100 125 150 300 420 4 VS30U03E15 - * 8967. VJ30V03E06 - * 10065.
320 100 125 200 250 300 600 850 5 VS30U03515 - * 9333. VJ30U03506 - * 10431.
600 200 200 375 500 575 1200 1600 6 VS30U03615 - * 22052. VJ30U03606 - * 23534

3 Pole Wired Reversing Starters, 1501V-3600V - Bulletin 6030


Open Type 3600V1
Maximum Horsepower Ratings - 3 Phase
Ampere Standard Duty
Rating 3 2300V 3300V Catalog No. E Price
160 600 960 VS30U03E36 - * $ 8711.
320 1250 1920 VS30U03536 - * 10358.

For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)


Note:
1. Three overload heaters are required.
2. To be used when application involves plugging & inching (e.g. crane control). Includes M.O.V. suppressors on power
circuit. For other voltages consult factory.
3. Terminal boots provided on center phase.
Ordering Information Coil Table
Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil table. Modification Data page A37. 120 - 76
Order Heaters at $18.00 each from page A35. Renewal Parts page A36. 240 - 26

Discount Schedule JC11 A25


Low Voltage - USAVAC AC Combination Starters
CV Series

300 HP 460V Starter in Type 12 Enclosure 400 HP 600V Starter in Type 3 Enclosure

NEMA 1 & 12 Combination Starters 200V-575V - Bulletin 6018/6020


2
Maximum Horsepower Ratings - 3 Phase NEMA Type 1 & 12
Ampere Flange Operator
Rating 200/208V 230V 380V 460V 575V Size Catalog No. Price
Non-Fusible
135 40 50 75 100 125 4 CV18TA340610 - * $ 5216.
200 50 80 135 150 200 -- CV18TA32A610 - * 6131.
270 100 100 200 200 200 5 CV18TA35610 - * 6497.
400 160 160 270 300 400 -- CV18TA34A610 - * 8747.
600 180 250 300 500 500 6 CV18TA360610 - * 14915.

Fusible
135 40 50 75 100 125 4 CV18TA340692 - * 5474.
200 50 60 100 125 150 4 CV18TA3E0692 - * 6497.
270 100 100 200 200 200 5 CV18TA35694 - * 6863.
400 160 160 270 300 400 -- CV18TA34A697 - * 9113.
600 180 250 300 500 500 6 CV18TA360698 - * 15354.
MCP
135 40 50 75 100 125 4 CV20TA340678 - * 5765.
200 50 80 135 150 200 -- CV20TA37678 - * 6863.
270 100 100 200 200 200 5 CV20TA350679 - * 7229.
400 160 160 270 300 400 -- CV20TA34A681 - * 9992.
600 180 250 300 500 500 6 CV20TA360681 - * 16799.

For NEMA 3R use NEMA 12 price and change 5th character of catalog number to
"R".
For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)

Note:
1. Three overload heaters are required.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil table. Modification Data page A37. 120 - 76
Order Heaters at $18.00 each from page A35. Renewal Parts page A36. 240 - 26

A26 Discount Schedule JC11


Low Voltage - USAVAC AC Combination Starters
VS Series

250 HP 460V Starter in Type 12 Enclosure 300 HP 600V Starter in Type 3 Enclosure

NEMA 1 & 12 Combination Starters 200V-575V - Bulletin 6018/6020


2 1, 2
Maximum Horsepower Ratings - 3 Phase NEMA Type 1 & 12
Ampere Flange Operator
Rating 200/208V 230V 380V 460V 575V Size Catalog No. Price
Non-Fusible
135 40 50 75 100 125 4 VS18TA340610 - * $ 5216.
2 100 125 4 6131.
160 50 60 150 VS18TA3E0610 - *
2 100 100 200 250 300 5 6497.
320 VS18TA350610 - *
600 180 250 300 500 500 6 VS18TA36A610 - * 14896.

Fusible
135 40 50 75 100 125 4 VS18TA340692 - * 5472.
2
160 50 60 100 125 150 4 VS18TA3E0692 - * 6497.
2
320 100 100 200 250 300 5 VS18TA350694 - * 6863.
600 180 250 300 500 500 6 VS18TA360697 - * 15354.
700 225 300 500 550 700 -- VS18TA370698 - * 16141.
MCP
135 40 50 75 100 125 4 VS20TA340678 - * 6057.
160 50 60 100 125 150 4 VS20TA3E0678 - * 6551.
320 100 100 200 250 300 5 VS20TA350679 - * 7119.
600 180 250 300 500 500 6 VS20TA360680 - * 16214.
700 225 300 500 550 700 -- VS20TA370681 - * 19618.

For NEMA 3R use NEMA 12 price and change 5th character of catalog number to "R".

For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)

Note:
1. Three overload heaters are required.
2. Terminal boots provided on center phase.
2
4
5

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil Modification Data page A37. 120 - 76
table. Order heaters at $18.00 each from page Renewal Parts page A36. 240 - 26

Discount Schedule JC11 A27


Reduced Voltage Starters Low Voltage - USAVAC

A Reduced Voltage - 600 Volts Rated


Type CV & VS Auto Transformer Closed
Transition
Designed for automatic starting of squirrel cage motors when the
starting current must be reduced. Closed transition
auto transformer starters provide the highest possible starting
torque per ampere of line current.

Auto transformers are 3-coil type, with voltage taps at 50%. 65%
and 80% rated in accordance with NEMA Standards ICS-214.21
for medium-duty starting service.

250HP, 460V R.V.A.T. Starter in NEMA 12 Enclosure

Vacuum Starters NEMA 1 & 12 Enclosed


Maximum Horsepower Rating 3 Phase NEMA 1 & 12, 230V 1 NEMA 1 & 12, 460V 1
Ampere Industrial - Dust tight Industrial - Dust tight
Rating 230V 460V Size Catalog No. Price Catalog No. Price

Non Combination - Bulletin 6082


135 50 100 4 CV82TA4JB - * $13862. CV82TA4ME - * $14183.
2
160 60 125 4 VS82TAEKB - * 14439. VS82TAENE - * 14732.
200 75 150 -- CV82TA2ALB - * 14622. CV82TA2APE - * 14878.
320 2 100 250 5 VS82TA5MB - * 14988. VS82TA5RE - * 15354.
400 150 300 -- CV82TA4APB - * 19197. CV82TA4ASE - * 21301.
600 200 500 6 CV82TA6QB - * 30543. CV82TA6VE - * 31092.

Fusible Combination - Bulletin 6083


135 50 100 4 CV83TA4JB - * 15692. CV83TA4ME - * 16241.
160 2 60 125 4 VS83TAEKB - * 16690. VS83TAENE - * 17056.
200 75 150 -- CV83TA2ALB - * 17111. CV83TA2APE - * 17531.
2
320 100 250 5 VS83TA5MB - * 17550. VS83TA5RE - * 17897.
400 150 300 -- CV83TA4APB - * 21393. CV83TA4ASE- * 22619.
600 200 500 6 CV83TA6QB - * 34953. CV83TA6VE - * 35996.

MCP Combination - Bulletin 6084


135 50 100 4 CV84TA4JB - * 15775. CV84TA4ME - * 16141.
2
160 60 125 4 VS84TAEKB - * 16452. VS84TAENE - * 16818.
200 75 150 -- CV84TA2ALB - * 16653. CV84TA2APE - * 17056.
2
320 100 250 5 VS84TA5MB - * 17001. VS84TA5RE - * 17550.
400 175 350 -- CV84TA4APB - * 22253. CV84TA4ASE - * 23406.
600 200 500 6 CV84TA6QB - * 34441. CV84TA6VE - * 35154.

Note:
2
4
1. Includes starter complete with 3 N.O. & 2 N.C. interlocks and three phase overload relays less heaters.
5 2. Terminal boots provided on center phase.
D
3. For NEMA 3R change the T in the catalog number to an R.

Ordering Information Coil Table


Use complete catalog number when ordering. Replace the (*) with Engineering Data page A30. Voltage Suffix
the suffix from the coil table. Order heaters at $18.00 each from Modification Data page A37. 120 - 76
page A35. Refer to factory for 220, 380 or 575 HP ratings. Renewal Parts page A36. 240 - 26

A28 Discount Schedule JC11


USAVAC - Low Voltage AC Vacuum Contactors
Special Purpose Contactors

3 Pole Three Phase 1000A 3600V

The following controls are for high current applications such as electric arc and induction furnace.

Special Purpose Vacuum Contactors


Ampere 1500V Open Type 3600V Open Type
Rating Catalog No. Price Catalog No. Price
1 Pole, Single Phase
450 SVC77U014515 - * $ 3431. SVC77U014536 - * $ 5627.
1000 SVC77U011015 - * 6050. SVC77U011036 - * 7137.
1500 SVC77U011515 - * 8711. SVC77U011536 - * 9132.
2500 SVC77U012515 - * 9516. SVC77U012536 - * 10138.
.
2 Pole, Single Phase
1
450 SVC77U024515 - * 7851. SVC77U024536 - * 8510.
1
1000 SVC77U021015 - * 8327. SVC77U021036 - * 9132.
1
1500 SVC77U021515 - * 16653. SVC77U021536 - * 17056.
3 Pole, Three Phase
2
1000 SVC77U031015 - * 10797. SVC77U031036 - * 12444.

Note:
1. Insulation boots provided on 1 pole.
2. Terminal boots provided on all phases.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A30. Voltage Suffix
Replace the (*) with the suffix from the coil table. Renewal Parts page A36. 120 - 76
240 - 26

Discount Schedule JC11 A29


Engineering Data USAVAC - Low & Medium Voltage
Vacuum Contactor & Starter Ratings 200V-3600V Technical Specifications
Standards NEMA ICS 2-1988, UL 508 (1.5KV), CSA 22.2 (1.5KV), IEC 158-1, BS 547-1

A Catalog No. 3 Pole 1.5KV


160A
VC77U03415
320A
VC77U03515
600A
VC77U03615
1000A
SVC77U031015
3.6KV VC77U03436 VC77U03536 VC77U03636 SVC77U031036
Power Ratings
Rated Insulating and
1500/36001
Operational Voltage
Rated Operational Current 160 320 600 1000
Rated Frequency 50/400Hz
Making Current 1600 3200 6000 6000
Breaking Current 1600 3200 6000 6000
Dielectric Strength/BIL. 6KV-1 min. / 45KV. 1.2 X 50 Micro/Sec.
Interrupting Current 4400 5000 6000 6000
Open Type
Withstand Current 30KA-3Hz USAVAC Starter Size 5
Short Time Current - 1 Sec. 5000 7000 9000 11000
2 Sec. 3000 5000 7000 9000 Accessories & Options:
1. Mechanical Interlocked contactors
Mechanical Life 2 x 10 6
available, pages A22/23.
Electrical Life at Rated
2. Vacuum starters in combination and
Current - AC3 Duty 1 x 106 non-combination forms are available
Switching Frequency 600/hr every 6 seconds in NEMA 1, 3, and 12 enclosures on,
Chop Current Mean .55A pages A24, 26 & 27
Max. .9A 3. Terminal Lug Kits, page A36.
4. Suppressor Kits, page A36.
Control Ratings
Description 160/320A 600A 1000A For KW Rating Multiply HP Ratings by .746
(example: 100HP x .746 = 75KW)
Rated Control Voltage 120/240V 50/400Hz
Allowable Fluctuation +10% of rated Power Application Ratings
-25% voltage
Motor HP 2
Closing Power VA/Duration 950VA/17MS 1900VA/17MS 2850VA/17MS Volts 160A 320A 600A 1000A
Holding Power 9VA 18VA 27VA
230 60 125 200 -----
Opening Time Ave. 90 MS at 60Hz
460 125 250 500 -----
Closing Time Ave. 17 MS at 60Hz
1000 300 600 1200 -----
Pick up Voltage 90V
1500 420 850 1600 -----
Drop Out Voltage 70% or less
When Required When Required When Required 2300 600 1250 2400 -----
Recommended
3300 960 1920 3700 -----
Control Transformer 250VA 500VA 750VA
Transformer Load KVA
Application Conditions
Volts 160A 320A 600A 1000A
Installation All Planes contactor only
230 66 133 250 415
Altitude without Derating Up to 6600 ft. (2000m)
460 127 255 500 746
Ambient Storage -650F (-540C) +1600F (710C)
1000 277 554 1000 1730
Operating -400F (-400C) +1350F (570C)
1500 415 850 1500 2600
Vibration/Shock 40Hz - 2G/30G
2300 665 1330 2500 4150
Weight 160/320A 12lbs. (5.45kg.) 24lbs. (11kg.) 36lbs. (16.36kg.) 3300 910 1820 3400 5700
Dimensions 8 7/8" x 7 7/16 x 7 7/8" 17 7/8"x7 7/16x7 7/8" 265/8"x7 7/16x7 7/8" Capacitor Load KVAR
225 x 189 x 200mm 450x189x200mm 676x189x200mm Volts 160A 320A 600A 1000A
230 50 100 180 310
460 95 190 360 595
1000 205 415 750 1300
1500 310 620 1125 1450
2300 500 1000 1875 3110
3300 700 1365 2550 4275
UL/CSA 1500V
Note:
UR/CSA 3600V
1. 3600V model has a B.I.L. rating of 45KV and an interrupt
Control Diagram rating of 4000A.
2. Motor applications ratings are limited to 1000A continuous
with maximum LRC of 6000 ampere.

A30
Low & Medium Voltage - USAVAC Dimensions

A31
Dimensions USAVAC - Low Voltage

700 Amp
A 600V
3 Phase

Mechanically Interlocked 160/320A Contactors Mechanically Interlocked 600A Contactors

Mechanically Interlocked Contactors


3 Pole/5 Pole 160-320A
Open, Reverser, Standard or Jogging Duty
160-320A

Open Type, Reverser Standard, or Jogging Duty 600A

A32
Low Voltage - USAVAC Dimensions

A33
Dimensions USAVAC - Low Voltage

A34
USAVAC - Low & Medium Voltage Overload Heaters
Heater Selection Ambient Correction
Select heaters based on motor nameplate full-load current. Tables are Not necessary when overload relay is ambient compensated as
for continuous rated motors. Full-load current for a given horsepower identified by green reset rod. For control at an ambient constantly less
motor will vary from one manufacturer to another and will depend on RPM than the motor ambient, correct by decreasing the nameplate motor
of motor. full-load current by 8% per 100C difference in ambient.
For control at an ambient constantly greater than the motor ambient,
A
Type of Protection correct by increasing the nameplate motor full-load current by 8% per
Heaters selected directly from the tables provide a maximum of 125% 100C difference in ambient.
protection at 400C ambient, is suitable for motors with a 1.15 service
factor with a 400C rise or less and with motor and controller at the same Branch Circuit Protection
temperature. For motors with 1.0 service factor or with a temperature Branch circuit protection should be provided per USA National Electric
rise greater than 400C without service factor rating, use one size smaller Code or the Canadian Electrical Code. Current rating of the protective
heaters than in table. The ultimate trip of the heater is approximately 125% device must not exceed the maximum value listed in the table.
of the minimum current shown in the tables in a 400C ambient.
The overload relay provides protection in accordance with UL Class 20. Automatic Reset
For further data refer to Controlog section B. Automatic reset operation should not be used with two-wire control.

CV 4 HEATER APPLICATION TABLE ALL HEATERS


NON-REVERSING, REVERSING AND MULTI-SPEED, WITH STANDARD $18.00 LIST
OR AMBIENT COMPENSATED OVERLOAD RELAY
HEATER APPLICATION ENCL. STANDARD TYPE
OPEN OR ENCL. HEATER APPLICATION TABLE
TABLE AMBIENT COMP. TYPE
INVERSE
FOR 3 PHASE MOTORS PROTECTIVE TIME FOR 3 PHASE MOTORS
MOTOR CONTINUOUS HEATER DEVICE BREAKERS Bul. 6013, 6030, & 6050 Type CV5, CV6, CV400 &
Bul. 6013, 6030, & 6050 Type AMPERE RATING CATALOG MAXIMUM CONT. STARTER CV600. Standard or Ambient Compensated Overload
NUMBER FUSE AMPS. SIZE Relay for use with 500:5 Current Transformer
CV-200 Standard or Ambient MIN. MAX.
Compensated Overload Relay for ▲ HEATER STARTER
28.6 31.6 2525 125 70
use with 400:5 CAT. NO. MIN. MAX. SIZE
31.7 35.2 2526 125 70 ▲ ▲ ▲ ▲
Current Transformer 35.3 39.1 2527 150 70 2425 198.0 215.0
39.2 42.3 2528 150 70 2426 215.1 237.0 5
HEATER 2529 175 100
3
42.4 46.4 2427 237.1 267.0
CAT. NO. MIN. MAX. 46.5 50.8 2530 200 100
57.3 2531 225 100 2429 267.1 270.0 ▼
2421 87.0 96.5 50.9
57.4 63.7 2532 250 100 2429 267.1 289.0 400A
2422 96.6 104.9 70.7 2533 250 100 2430 289.1 324.0
63.8
2423 105.0 117.7 70.8 77.3 2534 300 125 2431 324.1 351.0 6
2424 117.8 131.1 77.4 83.1 2535 300 150 4
2432 351.1 390.0
2425 131.2 137.5 83.2 90.0 2536 300 150 ▼ 600A
2433 390.1 400.0 ▼
2426 137.6 152.9 2433 390.1 425.0
83.2 90.9 2536 350 150
2427 153.0 171.4 91.0 97.6 2537 350 150 2434 425.1 487.0
2429 171.5 185.5 97.7 106.0 2538 400 150 2435 487.1 540.0 ▼
2430 185.6 200.0 106.1 115.4 2539 450 200
450 200 2435 487.1 548.0
115.5 123.9 2540
124.0 135.0 2541 450 200 2436 548.1 600.0 ▼

HEATER APPLICATION TABLE HEATER APPLICATION TABLE


FOR 3 PHASE MOTORS FOR 3 PHASE MOTORS HEATER APPLICATION TABLE
FOR 3 PHASE MOTORS
BUL. 6013 TYPE VS SIZE 4 Bul. 6013, 6030, & 6050 Type VS Size 4, E, and
STANDARD OR AMBIENT 5 Standard or Ambient Compensated Overload Type VS Size 6 Standard or
COMPENSATED OVERLOAD RELAY Relay for use with 400:5 Current Transformer Ambient Compensated Overload Relay
MIN. MAX. 600 A. STARTER SIZE For use with 400/5 Current Transformer
MOTOR CONTINUOUS ▲ ▲ ▲
AMPERE RATING 44.9 49.6 2413 INVERSE TIME
HEATER 49.6 56.0 2414
CATALOG HEATER MOTOR CIRCUIT BREAKER
56.1 61.6 2415 CATALOG AMPERE MAGNETIC TRIP
MIN. MAX. NUMBER
NUMBER RATING SETTING
29.2 32.3 2525 61.7 68.0 2416 4
68.1 76.7 2417 MAX. MIN. 600 A. 800 A.
32.4 36.0 2526
36.1 39.9 2527 76.8 81.5 2418 2421 106.0 95.2 LOW LOW
81.6 89.4 2419 E 2422 121.0 106.1 LOW LOW
40.0 43.4 2528
89.5 94.1 2420 2423 136.0 121.1 LOW LOW
43.5 47.6 2529
2424 158.0 136.1 LOW LOW
94.2 105.9 2421 5
47.7 52.4 2530 106.0 119.9 2422 2425 172.0 158.1 LOW LOW
52.5 59.2 2531 120.0 134.4 2423 2426 190.0 172.1 LOW LOW
59.3 66.0 2532 134.5 135.0 2424 ▼ 2427 214.0 190.1 LOW LOW
66.1 73.3 2533 135.1 156.9 2424 2429 231.0 214.1 LOW LOW
73.4 80.4 2534 157.0 160.0 2425 2430 259.0 231.1 LOW LOW

2431 281.0 259.1 2 LOW
80.5 87.9 2535 160.1 170.9 2425 2432 312.0 281.1 3 LOW
171.0 188.9 2426
189.0 211.9 2427 2433 340.0 312.1 3 LOW
88.0 95.0 2536
95.1 102.7 2537 212.0 229.9 2429 2434 390.0 340.1 4 2
102.8 111.9 2538 230.0 256.9 2430 2435 438.0 390.1 6 3
2436 484.0 438.1 7 3
112.0 122.9 2539 257.0 280.9 2431 2437 520.0 484.1 HIGH 4
123.0 133.9 2540 281.0 304.0 2432 2438 590.0 520.1 HIGH 6
134.0 145.0* 2541* 304.0 320.0 2433 ▼ 2439 600.0 590.1 HIGH 6

Discount Schedule JC16 A35


Accessories / Parts Vacuum Control - USAVAC

A Low Voltage Contactors 200V - 3.6Kv


Rating
Description Catalog Number Price (Each)
Accessories - Discount Schedule JC11
Line Side (1 Per Kit) KVC-UB1 $ 33.
Terminal Boots
Load Side (1 Per Kit) KVC-UL1 33.
6-250 MCM (3 Per Kit) KVCL-250 82.
Lug Kits (3 per kit) 4-500 MCM (3 Per Kit) KVCL-500 104.
2-600 MCM (3 Per Kit) KVCL-600 126.
631.
Suppressor Kits 600V, (1 - 3 Phase/Kit) VCSK600

Parts - Discount Schedule JC80


160 ampere (1 Per Kit) A77-354115A-1 1041.
320 ampere (1 Per Kit) A77-354115A-2 1214.
Phase Assembly Fig. 1
600 ampere 1 A77-354115A-2 1214.
1000 ampere 1 A77-354115A-2 1214.
Control Module Fig. 2 120/240V, 50/60Hz (1 Per Kit) A77-354117A 972.
125V DC (1 Per Kit) A77-452580-A2 972.
250V DC (1 Per Kit) A77-452580-A4 972.

Note:
1. When ordering for 600A Rating, Qty. (2) of a 320A Phase Assembly are required Per Pole.
When ordering for a 1000A Rating, Qty. (3) of a 320A Phase Assembly are required Per Pole.
Example:600A = 2-A77-354115A-2, Price $1214 X 2 = $2428. Total For 1 Pole.
1000A = 3-A77-354115A-2, Price $1214 X 3 = $3642. Total For 1 Pole.

Medium Voltage Contactors 2.3 - 7.2Kv


Description Rating Catalog Number Price (Each)
Accessories - Discount Schedule JC19
4-350 MCM, (2 - Wires/Lug) KVCL-350 $ 97.
Lug Kits (3 per kit)
4-500 MCM, (1 - Wire/Lug) KVCL-500 104.
2.3KV, (1 - 3 Phase/Kit) VCSK2300 1894.
4.16KV, (1 - 3 Phase/Kit) VCSK4160 2031.
Suppressor Kits 6.6KV, (1 - 3 Phase/Kit) VCSK6600 2031.
Auxiliary Contacts 2N.O. & 2 N.C. Auxiliary Block A77-358002-A 73.

Parts - Discount Schedule JC80


200 ampere (1 Per Kit) A77-356249A-1 1145.
400 ampere (1 Per Kit) A77-356249A-2 1352.
Phase Assembly Fig. 3 600 ampere (1 Per Kit) A77-356249A-3 1559.
(Half Shell) 700 ampere A77-356249A-5 1559.
1200 ampere A77-356249A-4 3118.
Phase Assembly Complete 3 Phase Assembly A77-359473-A 3989.
Complete 1 Pole Assembly A77-359473-B 1470.
120V, 50/60Hz (1 Per Kit) A77-356277A-1 1179.
Control Module Fig. 4 240V, 50/60Hz (1 Per Kit) A77-356277A-2 1179.
380/460V,50/60Hz A77-356277A-4 1179.
125V DC (1 Per Kit) A77-452563-A2 1179.
250V DC (1 Per Kit) A77-452563-A4 1179

A36
Low
USAVAC - Vacuum Control Voltage Modifications

Modifications For Combination and Non-Combination Controllers


Enclosure Type Change Cat. No.
Description NEMA 1, 3, 3R, 4, 12 Character Indicated To: Typical Catalog Number
Cover Controls
Push Buttons & Selector Switches
Hand-Off-Auto Selector Switch B
$ 264.
Start-Stop Push Buttons C
2 or 3 Position Selector Switch - SPDT B
264.
Forward-Reverse-Stop Push Buttons C
High-Low-Stop Push Buttons
480. C
Fast-Slow-Stop Push Buttons

Pilot LightsWithout Electrical Interlock:


With Electrical Interlock: 11
Standard Transformer Type, Red Lens 324. 13
Push-to-Test Transformer Type, Red Lens 504. 14 V S18 A A 5 069 0 - 76- ( )
Modification 11-14. Lens color below. Example: Order
11 + 15 = Std. Transformer with interlock & color lens
Green N/C 13+15
Blue N/C 13+16
White N/C 13+17
Yellow N/C 13+18
Amber N/C 13+19
Clear N/C 13+20
Auxiliary Relays
Control Relay 4 Pole Maximum 2 N.O., 2 N.C. 560. 21
Time Relay ON Delay 922. 22
Time Relay OFF Delay 922. 23
Time Relay ON Delay & Instantaneous 1032. 24
Time Relay OFF Delay & Instantaneous 1032. 25
Time Relay ON Delay & OFF Delay 1169. 26

3
7
Ordering & Pricing Example: 5

VS18TA350694-76 with the following modifications: VS18TA350694-76 6863.


1 - Hand-Off-Auto Selector Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . . . . . 264.
.
1 - Transformer operated Red Pilot with Interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . 324.
.
1 - Transformer operated Green Pilot Light with Interlock . . . . . . . . . . . . . . . . . . . . 13
. + 15 . . . . . . +. 324.
$ 7775. Total

Discount Schedule JC11 A37


Low
Voltage Modifications Vacuum Control - USAVAC

Modifications
A Description Price
Change Cat. No.
Character Indicated To: Typical Catalog Number

Overload Relay
$
777 Electronic Motor Management Relay 970 1775. 2728
RM 2000 motor Monitor for use with 777 DEDUCT 695. 29
27A
Power Circuit
Standard Capacity - Primary Volts/Hertz:
220-240/60 or 220/50 -T26
440-480/60 or 440/50 747. -T46
550-600/60 or 550/50 -T56
200-208/60 -T86
380/50 1021. -T35
220/25 -T22
440/25 1120. -T42
100 Watts Extra - Primary Volts/Hertz:
220-240/60 or 220/50 -C26
440-480/60 or 440/50 966. -C46
550-600/60 or 550/50 -C56
200-208/60 -C86
380/50 -C35
220/25 -C22
VS 18 A A 3 1 6 0 3 - 46 -( )
440/25 1449. -C42
Fused Primary (Includes 2 Fuses) 242. 30
Control Circuit Separate N/C 31
Fused Control Circuit, 2 fuses included 242. 32
33 Phase
Phase Voltage
Voltage Monitor Relay (Phase
Monitor Relay, loss, Phase
Phase loss, Phase reversal
reversal) 2141. 33A
Ammeter & 1-Current Transformer
Ammeter, Switch,
Digital Power Meter& 3-Current Transformers 1700.
Voltmeter 3 Phase
* Ammeter 3 Phase * Digital Power Meter: 1700.
Voltmeter
* Voltmeter& 3Switch
Phase3 Phase All functions included in 1700.
Elapsed
* Power Time
(KW)Meter
Wattmeter Mod. 35A 3
Wattmeter
* Energy (KWH) KWH Meter 48.
Watthour
* PF MeterMeter 3331. 35A
Operations
* FrequencyCounter
Meter 8 Digit 348.
Space Heater
* Reactive with(KVAR)
Power N.C. Auxiliary 604.
Contactors without Power Wire N/C
Contactors MI 320/160A 3 Phase ---- See page A22
Contactors MI 600/320A 3 Phase ---- See page A22

4
7
Ordering & Pricing Example:
5
VS18TA350694-76 with the following modifications: VS18TA350694-76 6863.

1 - 3 Phase Voltage Monitor Relay (Phase loss, Phase reversal) . . . . . . . . . . . . . . . . . . . 33A +2141.
Complete Cat# VS18TA350694-76-33A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 9004. Total

A38 Discount Schedule JC11


Medium Voltage - USAVAC AC Vacuum Contactors
UL Recognition 1
CSA Certified 1
A
Electrically Held
AC or DC Closing
Coils

Ratings Include 2.5, 5.0, 7.2KV,


200, 400, 600, 800 and 1200 Ampere

3 Pole Vacuum Contactors - Bulletin 7707


Ampere Maximum Horsepower Ratings Open Type
Rating .8pf Ind. or Syn. Motor 1.0 pf Syn. Motor Catalog No. Price
2500 Volts
200 900 1000 MVC77U032A25 - * $ 3331.
400 1750 2000 MVC77U034A25 - * 3459.
600 2250 2500 MVC77U036A25 - * 4118.
800 2750 ----- SVC77U038A25 - * 8327.
1200 ----- ----- SVC77U031225 - * 9974.
4160 Volts
200 1500 1750 MVC77U032A50 - * 3468.
400 3000 3500 MVC77U034A50 - * 3605.
600 4500 4750 MVC77U036A50 - * 4200.
800 5500 ----- SVC77U038A50 - * 8455.
1200 ----- ----- SVC77U031250 - * 10394.
6600 Volts
200 2500 2750 MVC77U032A72 - * 3642.
400 5000 5250 MVC77U034A72 - * 4118.
600 6750 7000 MVC77U036A72 - * 5472.
800 8000 ----- SVC77U038A72 - * 9113.
1200 ----- ----- SVC77U031272 - * 10907.

Note:
1. UL recognized 5KV 500A 7.2KV 400A 3
CSA Certified 5KV 400A 7
5

Mechanically Interlocked Contactors on Page A41 should be used if short circuit


current can flow when switching between two or more contactors.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A43. Voltage AC Suffix Voltage DC Suffix
120 -76 125 -125
Renewal Parts page A36. 240 -26 250 -250

Discount Schedule JC11 A39


Medium Voltage - USAVAC AC Vacuum Contactors
UL Recognized
CSA Certified 5KV 400A

A With Separate
Mechanically Latched
Close and Trip Coils

Ratings Include 2.5, 5.0, 7.2KV,


200, 400, 600 Ampere

3 Pole Vacuum Contactors - Bulletin 7707


Ampere Maximum Horsepower Ratings Open Type
Rating .8pf Ind. or Syn. Motor 1.0 pf Syn. Motor Catalog No. Price
2500 Volts
200 900 1000 MVCL77U032A25 -* $ 4154.
400 1750 2000 MVCL77U034A25 -* 4282.
600 2250 2500 MVCL77U036A25 -* 4850.
1200 MVCL77U031225 -* 10614.
4160 Volts
200 1500 1750 MVCL77U032A50 -* 4282.
400 3000 3500 MVCL77U034A50 -* 4429.
600 4500 4750 MVCL77U036A50 -* 5014.
1200 MVCL77U031250 -* 10943.
6600 Volts
200 2500 2750 MVCL77U032A72 -* 4465.
400 5000 5250 MVCL77U034A72 -* 4941.
600 6750 7000 MVCL77U036A72 -* 6295.
1200 MVCL77U031272 -* 12700.

Note:
Mechanically Interlocked Contactors on Page A41 should be used if short circuit
current can flow when switching between two or more contactors.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A43. Voltage AC Suffix Voltage DC Suffix
Replace the ( * ) with the suffix from the coil Renewal Parts page A36. 120 -76 125 -125
table. 240 -26 250 -250
EXAMPLE: MVCL:77UO3450-76-125 (120V
AC Close Coil 125V DC Trip Coil)

A40 Discount Schedule JC19


USAVAC - Medium Voltage Mechanically Interlocked Contactors

3 Pole - 3 Pole Mechanically Interlocked - Bulletin 6031


Ampere Maximum Horsepower Ratings Open Type
Rating .8pf Ind. or Syn. Motor 1.0 pf Syn. Motor Catalog No. Price
2500V
200 900 1000 MVC31U032A25 - * $ 7759.
400 1795 2000 MVC31U034A25 - * 8015.
600 2250 2500 MVC31U036A25 - * 9150.
4160V
200 1500 1750 MVC31U032A50 - * 8015.
400 3000 3500 MVC31U034A50 - * 8308.
600 4500 4750 MVC31U036A50 - * 9479.
6600V
200 2500 2750 MVC31U032A72 - * 8381.
400 5000 5250 MVC31U034A72 - * 9333.
600 6750 7000 MVC31U036A72 - * 12041.

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A43. Voltage Suffix
120 -76
Renewal Parts Data page A36. 240 -26

Discount Schedule JC19 A41


AC Vacuum Contactors Medium Voltage - USAVAC
Special Purpose Contactors

3000A Single Phase


A 1200A Three Phase

The following controls are for high current applications such as electric arc and induction furnaces.

Special Purpose Vacuum Contactors - Bulletin 7707


Ampere Open Type, 2500V Open Type, 5000V Open Type, 7200V
Rating Catalog No. Price Catalog No. Price Catalog No. Price

1 Pole, Single Phase


1000 SVC77U011025 - * $ 3386. SVC77U011050 - * $ 3935. SVC77U011072 - * $ 4667.
1500 SVC77U011525 - * 5060. SVC77U011550 - * 5426. SVC77U011572 - * 6158.
2000 SVC77U012025 - * 6690. SVC77U012050 - * 7073. SVC77U012072 - * 8171.
3000 SVC77U013025 - * 10122. SVC77U013050 - * 10488. SVC77U013072 - * 11586.

2 Pole, Single Phase


200 SVC77U022A25 - * 2965. SVC77U022A50 - * 3102. SVC77U022A72 - * 3276.
400 SVC77U024A25 - * 3093. SVC77U024A50 - * 3239. SVC77U024A72 - * 3752.
600 SVC77U026A25 - * 3752. SVC77U026A50 - * 3834. SVC77U026A72 - * 5106.
1000 SVC77U021025 - * 9242. SVC77U021050 - * 9662. SVC77U021072 - * 10175.
1500 SVC77U021525 - * 10340. SVC77U021550 - * 10760. SVC77U021572 - * 11273.

3 Pole, Three Phase


800 SVC77U038A25 - * 8327. SVC77U038A50 - * 8455. SVC77U038A72 - * 9113.
1200 SVC77U031225 - * 9974. SVC77U031250 - * 10394. SVC77U031272 - * 10907.

3
9
5

Ordering Information Coil Table


Use complete catalog number when ordering. Engineering Data page A43. Voltage Suffix
Renewal Parts page A36. 120 -76
240 -26

A42 Discount Schedule JC19


USAVAC - Medium Voltage Engineering Data
Technical Specifications Vacuum Contactor & Starter Ratings
CSA 5KV. 400A Standard - NEMA ICS 2-324, UL 347, CSA 22.2 , IEC 470, BS 775
Description 200A 400A 600A 1200A
UL Recognized 5KV
500V 7.2KV 400A Catalog Number & 2.5KV MVC77U032A25 MVC77U034A25 MVC77U036A25 SVC77U031225
A
Rated VoltageMVC77U032A50
5.0KV MVC77U034A50 MVC77U036A50 SVC77U031250
7.2KV MVC77U032A72 MVC77U034A72 MVC77U036A72 SVC77U031272

Power Ratings
Operational Rated Current 200A 400A 600A 800/1200A
Operational Rated Frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
E1 Interrupt Rating 2.5KV 20 MVA Equivilent to 4.62 KA --------
MVA & KA Values 5.0KV 40 MVA Equivilent to 4.62 KA --------
Contactor Only 7.2KV 60 MVA Equivilent to 4.81 KA --------
E2 Fuse Co-ordination Rating 400 MVA 45.7 KA RMS --------
MVA & KA 5.0KV 38R max. fuse size
Withstand KA 5.0KV 57.8 KA - Peak, 38R - Fuse --------
Short Time Current 1 Sec. KA 6 7 9 12
5 Sec. KA 4 5 6 9
Power Application Ratings 15 Sec. KA 2 2.6 3 6
Switching Frequency 300/Hr
Voltage KV 2.5 3.3 4.16 6.6
Elec. Life at Rated Current .6 x 106 .40 x 106 .250 x 106 .250 x 106
Motor Type Current Motor HP Mechanical Life .75 x 106
.8 P.F. Ind. Dielectric Strength 20KV 1 min.
or Syn Motor 200A 900 1250 1500 2500 Impulse withstand B.I.L. 1.2 x 50 us
1.0 P.F. Syn 60KV
Motor 200A 1000 1500 1750 2750 Chopping Current Max. .9A
.8 P.F. Ind.
or Syn Motor 400A 1750
Control Ratings AC&DC
2250 3000 5000
1.0 P.F. Syn Rated Control Voltage 120/240V 50/60Hz AC 125/250V DC
Motor 400A 2000 2500 3500 5250 Allowable Fluctuation +10-15% +10-20%
.8 P.F. Ind. Closing Power VA/Duration 650VA/45MS 1300VA/45MS
or Syn Motor 600A 2250 3250 4500 6750 Holding Power 7VA AC .47A DC 14VA AC .924A DC
1.0 P.F. Syn Opening Time Ave. 90 MS at 60Hz
Motor 600A 2250 3500 4750 7000 Closing Time Ave. 40 MS at 60 Hz
.8 P.F. Ind. Pick up Voltage Min. 102V or less
or Syn Motor 800A 2750 4000 5500 8000 Drop Out Voltage Ave. 70% or less
Transformer Load KVA Recommended Control Trans. (AC Only) 300VA 600VA
Three 200A 750 1000 1500 2000
Application Conditions
Phase 400A 1500 2000 3000 4000
Transformer 600A 2500 3000 4250 6000 Standard Current Continuous AC/DC 10A/5A
800A 2750 3750 5250 7500 Auxiliary Voltage 600V Max. - 48V Min. NEMA A600 (AC) P600 (DC)
1200A 4100 5000 7000 10000 Contact AC Make/Break 7200VA/720VA
Capacitor Load KVAR Ratings DC Make/Break 125/250V 138VA 300/600V 138VA
Three 200A 550 750 1050 1500 Additional Current Continuous AC/DC 10A/2.5A
Phase 400A 1125 1500 2250 3000 Auxiliary Contact Voltage 600V Max. - 48 Min. NEMA A600 (AC) Q300 (DC)
Capacitor 600A 1650 2250 3375 4500 Relay Ratings AC Make/Break 7200VA/720VA
800A 2200 2900 4500 5000 DC Make/Break 125/250V/69VA
1200A 2750 3750 5625 7500 Weight 48 lbs. 96 lbs.

Accessories & Options:


1. 2, 4, & 5 Pole contactors, consult factory.
2. Mechanically interlocked contactors available, page A41.
3. Medium voltage starters available in non-drawout
designs in NEMA 12 & 3 enclosures, consult factory.
4. Terminal Lug Kits, page A36.

A43
USAVAC - Medium Voltage Dimensions

13.5" 12.63"
12"

B 26"

A 27.5"

1 2.5/5.0/7.2 KV 200, 400A


2.5/5.0/7.2 KV 1100A 3 Phase
2.5/5.0/7.2 KV 1000, 1500A 2 Pole
2.5/5.0/7.2 KV 2000, 3000A 1 Pole

2 600 AMP
A = 32"
B = 30.5"

A44
Dimensions Medium Voltage - USAVAC

A45
USAVAC Medium Voltage Controllers
Free Standing, Single High Compact Vacuum Starter in NEMA 12
FULL VOLTAGE Enclosures. Designed to comply with NEMA1CS2-324 Class E 2
NON REVERSING - REVERSING controller.
Features Offered:
A UL 347 LISTED
• Fault Make, Load break visible blade disconnect
switch with automatic grounding arm.
CSA 2-22 APPROVED • Grounded metal isolation between LV and
Medium Voltage Compartments.
• Maintenance free Joslyn Clark Vacuum Contactors.
• Suitably rated current limiting power fuses with
striker pins and 3 phase trip bar.
• C.P.T. provided with 2 primary and 1 secondary
fuses, 120V secondary.

Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
2300V VACUUM STARTERS With Fused Load Break Disconnect
160* 125 MVS18TA31A25A-T236 $17751
160* 150 MVS18TA31A25B-T236 17751
160* 250 MVS187A31A25C-T236 17751
160* 350 MVS18TA31A25D-T236 17916
160* 500 MVS18TA31A25E-T236 17916
160* 600 MVS18TA31A25F-T236 17952
200 750 MVS18TA32A25A-T236 18026
200 1000 MVS18TA32A25B-T236 18154
320* 1250 MVS18TA33A25A-T236 18483
400 1500 MVS18TA34A25A-T236 21045
600 2250 MVS18TA36A25A-T236 24449

Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
4160V VACUUM STARTERS With Fused Load Break Disconnect
200 200 MVS18TA32A50A-T416 $18117
200 350 MVS18TA32A50B-T416 18263
200 400 MVS18TA32A50C-T416 18263
200 500 MVS18TA32A50D-T416 18392
200 600 MVS18TA32A50E-T416 18392
200 750 MVS18TA32A50F-T416 18520
200 1000 MVS18TA32A50G-T416 18520
200 1250 MVS18TA32A50H-T416 18666
200 1500 MVS18TA32A50J-T416 18666
400 3000 MVS18TA34A50A-T416 21594
600 4500 MVS18TA36A50A-T416 25547

Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
7200 V
200 350 MVS18TA32A72A-T666 $20313
200 500 MVS18TA32A72B-T666 20313
200 750 MVS18TA32A72C-T666 20679
200 1000 MVS18TA32A72D-T666 20954
200 1500 MVS18TA32A72E-T666 21356
200 2000 MVS18TA32A72F-T666 22582
200 2500 MVS18TA32A72G-T666 23534
400 3500 MVS18TA34A72A-T666 24522
400 5000 MVS18TA34A72B-T666 26901
600 6750 MVS18TA36A72A-T666 32300
NOTE. For Reversing Applications add $9608. to list prices and change 4th and 5th digit of cat # from 18 to 31.
For Inching or Plugging Duty Refer to Factory.
For Latched Contactors change "MVS" to "MVSL" - - Add $1281. To List Price & specify Trip Coil Voltage.
* These Starters have 45KV BIL Rating if 60KV Required use 200A or 400A Rated Starters.
For NEMA 3R Rating Change 5th Digit from “T” to”R” & add $458 to list
Ordering Information
Engineering Data page A43 Renewal Parts page A36
Modification Data page A49 & 50

A46 Discount Schedule JC19


USAVAC Medium Voltage Controllers
Free standing, single high compact feeder capacitor. Feeder
controller to comply with NEMA1CS2-324.

• Fault Make, Load break visible blade disconnect


switch with automatic grounding arm.
A
• Grounded metal isolation between LV and
Medium Voltage Compartments.
• Maintenance free Joslyn Clark Vacuum Contactors.
• Suitably rated current limiting power fuses with
striker pins and 3 phase trip bar.
• C.P.T. provided with 2 primary and 1 secondary
fuses, 120V secondary.

KVA KVAR
Ampere Rating Ratings Rating Catalog No. Price
2300V VACUUM STARTERS With Fused Load Break Disconnect

200 AMP 750 550 MVF18TA32A25-T236 $18301

400 AMP 1500 1125 MVF18TA34A25-T236 $21777

600 AMP 2500 1650 MVF18TA36A25-T236 $24998

800 AMP 2750 2200 MVF18TA38A25-T236 $40553

1200 AMP 4100 2750 MVF18TA312A25-T236 $52667

KVA KVAR
Ampere Rating Ratings Rating Catalog No. Price
4160V VACUUM STARTERS With Fused Load Break Disconnect

200 AMP 1500 1050 MVF18TA32A25-T486 $18940

• Transformer ratings 400 AMP 3000 2250 MVF18TA34A25-T486 $22326

assume 100% continuous 600 AMP 4250 3375 MVF18TA36A25-T486 $25547


rating for operation at
800 AMP 5250 4500 MVF18TA38A25-T486 $44579
overload ratings
Consult Factory 1200 AMP 7000 5625 MVF18TA312A25-T486 $54772

• For latched contactors


change "MVF" to "MVFL" KVA KVAR
add 1281 to list price &' Ampere Rating Ratings Rating Catalog No. Price
specify trip coil voltage. 7200V VACUUM STARTERS With Fused Load Break Disconnect

200 AMP 2000 1500 MVF18TA32A25-T666 $21082

400 AMP 4000 3000 MVF18TA34A25-T666 $25803

600 AMP 6000 4500 MVF18TA36A25-T666 $30927

800 AMP 7500 5000 MVF18TA38A25-T666 $50911

Ordering Information
Engineering Data page A43 Renewal Parts page A36
Modification Data page A49 & 50

Discount Schedule JC19 A47


USAVAC - Medium Voltage Controllers
Designed for automatic starting of Squirrel REDUCED VOLTAGE AUTO TRANSFORMER
Cage Motors when the starting current or NON REVERSING - REVERSING
torque must be reduced. CLOSED TRANSITION UL 347 LISTED
A Joslyn Clark Reduced Voltage Auto CSA 2-22 APPROVED
Transformer Starters incorporate equipment
exactly as the full voltage starters, with the
additional following equipment
1- Free Standing Cubicle
Containing -:
1- 3 Pole StartingVacuum
Contactor
1- 3 Pole Shorting Vacuum
Contactor
1- Set of Mechanical
Interlocks
1- 3-Coil Auto -Transformer
with 50-65-80% taps.

2300V RVAT Starters With Fused Motor Load Break Disconnect

Max HP Cat # NEMA 12 List Price Max HP Cat # NEMA 12 List Price
*100 MVS83TA31A25A-T236 $32226. *1250 MVS83TA33A25F -T236 $40013.
*200 MVS83TA31A25B-T236 33050. 1500 MVS83TA34A25G-T236 41248.
*400 MVS83TA31A25C-T236 34953. 1750 MVS83TA36A25H-T236 43554.
*900 MVS83TA33A25D-T236 36637. 2000 MVS83TA36A25J -T236 45338.
*1000 MVS83TA33A25E-T236 38522. 2250 MVS83TA36A25K-T236 46976.

4160V RVAT Starters With Fused Motor Load Break Disconnect

100 MVS83TA32A50A-T416 $33398. 2000 MVS83TA34A50J -T416 $46482.


200 MVS83TA32A50B-T416 34203. 2250 MVS83TA34A50K-T416 48111.
400 MVS83TA32A50C-T416 36051. 2500 MVS83TA34A50L -T416 49593.
900 MVS83TA32A50D-T416 37844. 3000 MVS83TA34A50M-T416 51149.
1000 MVS83TA32A50E-T416 39674. 3500 MVS83TA36A50N -T416 52411.
1250 MVS83TA32A50F -T416 41157. 4000 MVS83TA36A50P -T416 53573.
1500 MVS83TA32A50G-T416 43261. 4500 MVS83TA36A50R -T416 54809.
1750 MVS83TA34A50H-T416 45110.

6600V RVAT Starter With Fused Motor Load Break Disconnect

1000 MVS83TA32A72E-T666 $45659. 4000 MVS83TA34A72P-T666 $61580.


1500 MVS83TA32A72G-T666 49758. 5000 MVS83TA34A72S-T666 63959.
2000 MVS83TA32A72J -T666 53573. 6000 MVS83TA36A72T-T666 66887.
2500 MVS83TA32A72L-T666 57032. 6750 MVS83TA36A72V-T666 70455.
3000 MVS83TA34A72M-T666 58835.

3
NOTE.
9
For NEMA 3R Replace 6th cat.# digit 'T' with 'R' and add $458. to list price. 5
For Reversing Applications add $13725. to list prices and change 4th and 5th digit of cat# from 83 to 86
For Inching or Plugging Duty Refer to Factory.
For Latched Contactor Change "MVS" to "MVSL" - - - Add $1464. to list price & specify trip voil voltage, refer controlog page A40.
* These Starters have 45KV BIL Rating for, 60KV Rating - - - Add $1556. to list price change cat# after TA31 to TA32 or TA33 to TA34.

Ordering Information
Engineering Data page A43 Renewal Parts page A36. • Modification Page A49 & 50

A48 Discount Schedule JC19


Modifications USAVAC Medium Voltage Controllers
Modifications For Combination USAVAC Medium Voltage Controllers
Enclosed Type Change Cat. No.
Description NEMA 1, 3R, 12 Character Indicated To: Typical Catalog Number A
Cover Controls
Push Button & Selector Switches
Hand-Off-Auto Selector Switch $ 264. B
Start-Stop Push Buttons C
2 or 3 Position Selector Switch B
264.
Forward-Reverse-Stop Push Buttons C
Pilot Lights
With Electrical Interlock:
Standard Transformer Type, Red Lens 324. 13
Push-to-Test Transformer Type, Red Lens 504. 14
Modication 13-14. Lens color. Example: Order
(13+15) = Std. Transformer with interlock & color lens
Green, Green N/C (13 + 15)
Example Blue N/C (13 + 16)
Pilot Light Red Lens -13 White N/C (13 + 17) MV S18T A 32A25B-T236-
Pilot Light Red Lens -(13 + 15) Yellow N/C (13 + 18)
Amber N/C (13 + 19)
Clear N/C (13 + 20)
Auxiliary Relays
Control Relay 4 Pole 2 N.O., 2 N.C. 612. 21
Time Relay ON Delay 1008. 22
Time Relay OFF Delay 1008. 23
Time Relay ON Delay & Instantaneous 1128. 24
Time Relay OFF Delay & Instantaneous 1128. 25
Time Relay ON Delay & OFF Delay 1278 26
Overload Relays
7777 Electronic Motor Management Relay 1775. 27
• (Includes Ground Fault Protection) No RTD Protected
• RM 2000 Motor Monitor (for use with 777 Relay)
Option 27 695. 27A
• 269+ Motor Management Relay Current Only 11895. 31
• 369+ Motor Management Relay Current Only 12261. 31A
• 369+ Motor Management Relay Current & Voltage 17660. 31B
• 469 + Motor Management Relay Drawout Case 21045. 30
• PQM Power Quality Meter 5856. 29
• Transformer Feeder Relay 745 25163. 62

Includes C/TS & P/T’s

Incoming & Auxilliary Cubicle Options


12” Cable Pull Section 2837 53
18” Cable Pull Section 3074 54
24” Cable Pull Section (use with option #29) 3569 55
400A Incoming Section Unit Unfused 6002 56
400A Incoming Section Unit Fused 8162 57
600A Incoming Section Unit Unfused 9333 58
600A Incoming Section Unit Fused 11621 59
1200A Incoming Section Unit Unfused 22509 60
1200A Incoming Section Unit Fused 30012 61

Discount Schedule JC19 A49


Modifications USAVAC Medium Voltage Controllers

A Description
Change Cat. No.
Price Character Indicated To: Typical Catalog Number

3 Phase Voltage Monitor Relay, Phase loss, Phase reversal 2141. 33A

Digital Power Meter


*Ammeter 3 Phase
*Voltmeter 3 Phase
*Digital Power Meter:
*Power (KW) Wattmeter 3331. 35A
All functions included in
*Energy (KWH) KWH Meter
Mod. 35A
*PF Meter
*Frequency Meter
*Reactive Power (KVAR)
MV S18T A 32A25-T236-
Elapsed Time Meter 637. 38
Operations Counter 8 digit 41
637.
Lightning Surge Protector 1610.
Overhead Bus 800A/Cubicle (24” Length) 1288. 47
Overhead Bus 1200A/Cubicle (24” Length) 2174. 48
Overhead Bus 1600A/Cubicle (24” Length) 4107. 49

* A ground Bus is included in busbar prices.

Overhead Bus 800A (36” Length) 30 or 36 1793. 50


Overhead Bus 1200A (36” Length) 30 or 36 2727. 51
Overhead Bus 1600A (36” Length) 30 or 36 5087. 52

Ordering & Pricing Example:

MVS18TA2A25-T236 with the following modifications:


MVS18TA32A25-T236 $18026
1 - Hand-Off-Auto Selector Switch ........................................................... B .... 264.
1- Transformer operated Red Pilot with Interlock ................................... 13 .... 324.
1- Transformer operated Green Pilot with Interlock ..................... (13 + 15) .... 324.
$18938 Total
Complete Cat. # is MVS18TA32A25-T236-33A-35A-41

Ordering & Pricing Example:

MVS18TA2A25-T236 with the following modifications


MVS18TA32A25-T236 $18026
1 - 3 Phase Voltage Monitor Relay, Phase loss, Phase reversal ...... 33A .. 2141.
1- Operations Counter 8 Digit .................................................................. 41 .... 637.
Digital Power Meter ............................................................................. 35A .. 3331.
1-777 Electronic Motor Management Relay ...........................................27 .. 1775.
1-Rm 2000 Motor Monitor ..................................................................... 27A .... 695.
$26605Total
Complete Cat. # is MVS18TA32A25-T236-33A-35A-41

A50 Discount Schedule JC19


Contactors & Starters Index NEMA Control

Description Page Number


General Information - TM ......................................................................... B2
AC Magnetic Contactors - TM .................................................................. B5
AC Magnetic Reversing Contactors - TM ................................................. B6
AC Magnetic Starters - TM ....................................................................... B7 B
AC Magnetic Reversing Starters - TM ...................................................... B8
AC Magnetic Two Speed Starters - TM .................................................... B9
General Information Combination Units - TM ......................................... B10
AC Magnetic Combination Starters - TM ................................................ B13
AC Magnetic Combination Reversing Starters - TM............................... B18
AC Magnetic Two Speed Combination Starters - TM ............................ B20
AC Magnetic Reduced Voltage A\T Starters - TM .................................. B26
AC Magnetic Wye Delta Starters - TM ................................................... B26
AC Magnetic Part Winding Starters - TM ............................................... B27
AC Pump Panels - Simplex .................................................................... B28
AC Panel Mounted Overload Relay ....................................................... B30
Heater Tables, TM, HP Starter ............................................................... B32
Factory Modifications - TM ..................................................................... B36
Field Modifications - TM ........................................................................ B39
Renewal Parts - TM................................................................................ B42
Dimensions - TM .................................................................................... B43
Engineering Data - Diagrams ................................................................ B50
Catalog Ordering Data .......................................................................... B60
Series 5000 AC NEMA Rated Contactors ............................................. B65

4
3
0

B1
TM - NEMA Control General Information

Operating Coils - All coils are encapsulated. Size 00


B Auxiliary Contacts -Auxiliary contact blocks thru 4 are plug-in type and each is factory tested twice,
may be added with the starter in place, without for long reliable service. Coil changes are not re-
tools. The same block is used on sizes 00 quired for any combination of add-on accessories.
thru size 4 as either N.O. or N.C.. A total of 4
auxiliary contacts can be added. The addition
of side mounting kits allows a total of 8
auxiliary contacts throughsize 4. Power Wiring - Up-front
terminals and straight
through design make power
wiring easy. As few as 3
connection points per pole
reduces the possibility of
loose connections and
contributes to the reliability of
the starter.
Power Pole - Full rated
power poles, N.O. or N.C.
through NEMA size 4, may
be field added, without coil
change. A tie pole with 2 N.O.
contacts is available for two-
speed single winding Contact Inspection - Loosen 2
(consequent pole) captive screws and remove the
motor applications. contact carrier, through size 4.

Overload Relay - Available with ambi-


ent compensation (green reset rod) or
non-ambient compensation (red
Adapter Plate - Allows use of Type TM reset rod). An easily accessible +
starters in place of other make s thru size 15, adjust-ment knob can be locked
2, without drilling new mounting holes. at the 100% setting. High accuracy
The adapter plate holes align with those of repetitive trip is assured by
of most other starters thru size 2 - proof of factory testing every unit twice.
the TM compact design.

Heaters - Heater numbers are stamped on the surface


for easy identification. The same heaters are used for
TM & HP series overload relays for both ambient and
non-ambient compensated overload relays.
3
8
0

Reliability - The basic contactor design, using polysulphone and teflon Versatility - Uniform mounting dimensions Add-on auxiliary
guides, melamine and rosite moldings along with stainless steel springs, contacts Plug-in coils Accessories, such as power pole,
provides exceptional electrical and mechanical life. The operating state mechanical interlock pro-vides maximum versatility and flexibility of
is clearly visible from the front, indicated by the position of the contact inventory panel layout and installation. Self-rising saddle-clamps
carrier.The contactor is easily operated from the front for circuit check- are included on all control terminals for quick wiring.
ing.

B2
General Information NEMA Control - TM

3
8
0

Compact Size - Integral overload relay design, with straight Uniform Mounting Dimensions - Only 2 mounting plate sizes for 00
through power cable design, provides compact overall size. through 4 starters. One mounting plate for sizes 00-2, the second for
Straight through wiring reduces overall panel area for a sizes 3 & 4. This provides great flexibility for intermixing
NEMA wired device. Uniform mounting dimensions, along with starter sizes in rows and reduces panel layout time.
mechanical interlock design, makes reversing devices and other Pilot Device Kits - Operator devices may be added in the field. Push
mechanically interlock devices the same height and depth as button and pilot light kits for non-combination enclosures are suitable for
nonreversing. This allows intermixing in rows and saves panel use in NEMA Type 1, 4 & 12. This simplifies selection and increases
space. flexibility.

B3
TM - NEMA Control General Information

Non-Reversing
Bulletin 6013 NEMA Starters.
Bulletin 7707 NEMA Contactors.
NEMA Size 00-6.
B NEMA Type 1, 4 & 12 Enclosures.
NEMA Size 00-2.
NEMA Type 3R Enclosure.
Bulletin 6013 Starters are available single phase through
size 2P, 3 phase through size 6.
Bulletin 7707 Contactors are available 2 & 3 pole through
size 6 and 4 pole thru size 4.

Reversing
Bulletin 6030 NEMA Starters.
Bulletin 6031 NEMA Contactors.
NEMA Size 00-6.
NEMA Type 1, 4, 12 Enclosures
Bulletin 6030 reversing starters and Bulletin 6031
reversing contactors include mechanical and
electrical interlocks.

Multi-Speed
Bulletin 6050 NEMA Starters.
NEMA Size 0-5.
NEMA Type 1, 4 & 12 Enclosures.
Bulletin 6050 multi-speed starters are designed for two-speed,
single winding (consequent pole) and two-speed, two winding
(separate winding) motor applications.
Mechanical and electrical interlocks are included.
Starters for three and four speed motor applications can also 3
be supplied. 8
0

B4
AC Contactors NEMA Control - TM

AC Contactors - Bulletin 7707 TM


1-Pole, Single Phase
Maximum Motor Starter NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower Rating Amps. GeneralPurpose Watertight Industrial - Dust-tight
NEMA Contin- Enclosure 1 Enclosure Enclosure
1 1 1
Size 115V 200V 230V uous Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
00 1
/3 ---- 1 9 T77A01A - * $ 228. Use Size 0 $ Use Size 0 $ T77U01A - * $ 204.
0 1 ---- 2 18 T77A010 - * 300. T77W010 - * 720. T77T010 - * 444. T77U010 - * 276.
1 2 ---- 3 27 T77A011 - * 360. T77W011 - * 792 T77T011 - * 504. T77U011 - * 336.

2 Pole, Single Phase


00 1
/3 ---- 1 9 T77A02A - * 264. Use Size 0 Use Size 0 T77U02A - * 240.
0 1 ---- 2 18 T77A020 - * 336. T77W020 - * 748. T77T020 - * 480. T77U020 - * 312.
1 2 ---- 3 27 T77A021 - * 396. T77W021 - * 828. T77T021 - * 540. T77U021 - * 372.
2 3 ---- 7 1/2 45 T77A022 - * 816. T77W022 - * 1680. T77T022 - * 1080. T77U022 - * 696.
3 7 1/2 ---- 15 90 T77A023 - * 1344. T77W023 - * 2568. T77T023 - * 1656. T77U023 - * 1104..

3 Pole, Three Phase


NEMA 460- Contin-
Size 200V 230V 575V uous
00 1 1/2 1 1/2 2 9 T77A03A - * 300. Use Size 0 Use Size 0 T77U03A - * 276.
0 3 3 5 18 T77A030 - * 372. T77W030 - * 792. T77T030 - * 516. T77U030 - * 348.
1 7 1/2 7 1/2 10 27 T77A031 - * 432. T77W031 - * 864. T77T031 - * 576. T77U031 - * 408.
2 10 15 25 45 T77A032 - * 864. T77W032 - * 1728. T77T032 - * 1128. T77U032 - * 744.
3 25 30 50 90 T77A033 - * 1440. T77W033 - * 2664. T77T033 - * 1752. T77U033 - * 1200.
4 40 50 100 135 T77A034 - * 3384. T77W034 - * 5472. T77T034 - * 4416. T77U034 -2 * 2880.
2 2 2
5 75 100 200 270 U77A035 - * 7200. U77W035 - * 9840. U77T035 - * 9840. U77U035 - * 6276.
6 150 200 400 540 See Vacuum Contactors in Section A
4 Pole, Three Phase
0 3 3 5 18 T77A040 - * 468. T77W040 - * 900. T77T040 - * 612. T77U040 - * 444.
1 7 1/2 7 1/2 10 27 T77A041 - * 528. T77W041 - * 960. T77T041 - * 672. T77U041 - * 504.
2 10 15 25 45 T77A042 - * 1080. T77W042 - * 2280. T77T042 - * 1344. T77U042 - * 960.
3 25 30 50 90 T77A043 - * 1776. T77W043 - * 3336. T77T043 - * 2088. T77U043 - * 1536.
4 40 50 100 135 T77A044 - * 4500. T77W044 - * 7464. T77T044 - * 5904. T77U044 - * 4008.
5 75 100 200 270 Consult Factory or See Vacuum Contactors in Section A
6 150 200 400 540 Consult Factory or See Vacuum Contactors in Section A

3
7
Note: 1. Price includes contactor complete with one N.O. control-circuit contact.
5 2. This unit replaces T77 (size 5) and is not interchangeable.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Engineering Data - see Page B50 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modifications - see Page B36 110-120/60 or 110/50 -76
Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Dimensions - see Page B43 440-480/60 or 440/50 -46
550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B5


TM - NEMA Control AC Reversing Contactors

AC Reversing Contactors - Bulletin 6031 TM


3 Pole, Three Phase
Maximum Motor 2 NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower Rating GeneralPurpose Watertight Industrial - Dust-tight
NEMA 460- Enclosure Enclosure Enclosure
1 1 1 1
Size 200V 230V 575V Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
1 1
00 1 /2 1 /2 2 T31A03A - * $ 768. T31W03A - * $ 1320. Use Size 0 $ T31U03A - * $ 720.
0 3 3 5 T31A030 - * 912. T31W030 - * 1464. T31T030 - * 1128. T31U030 - * 864.
1
1 7 /2 7 1/2 10 T31A031 - * 1056. T31W031 - * 1824. T31T031 - * 1272. T31U031 - * 984.
2 10 15 25 T31A032 - * 2064. T31W032 - * 3312. T31T032 - * 2424. T31U032 - * 1872.
3 25 30 50 T31A033 - * 3454. T31W033 - * 5292. T31T033 - * 4236. T31U033 - * 3108.
4 40 50 100 T31A034 - * 8376. T31W034 - * 11640. T31T034 - * 9600. T31U034 - * 7752.
2 3
5 75 100 200 U31A035 - * 17592. U31W035 -3 * 20232. U31T035 - *
3
20232. U31U035 -3 * 13980.
6 150 200 400 See Vacuum Contactors in Section A

Plug-Stop or Jogging Duty NEMA ICS 2-321-3

NEMA Horsepower Ratings - Three Phase, 60Hz


Notes: Size 200V 230V 380V 460/575V
1. Price includes contactor complete with one N.O. contact on each contactor. All 1
1 /2 1 1/2
0 1 1/2 2
contactors are mechanically and electrically interlocked. 1 3 3 5 5
2. For plug-stop or jogging duty, where operations exceed 5 times a minute, 2 7 1/2
1
7 /2 15 15
contactor size should be chosen in accordance with NEMA Standard ICS 2-321-3, 3 15 15 30 30
as listed in table. 4 25 30 50 60
3. This unit replaces T77 (size 5) and is not interchangeable. 5 60 75 125 150
6 125 10\50 250 300 3
7
5

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Engineering Data - see Page B50 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modifications - see Page B36 110-120/60 or 110/50 -76
Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Dimensions - see Page B43 440-480/60 or 440/50 -46
550-600/60 or 550/50 -56
200-208/60 -86

B6 Discount Schedule JC10


AC Non-Reversing Starters NEMA Control - TM

AC Non-Reversing Starters - Bulletin 6013 TM


2 Pole, Single Phase (requires 1 overload heater)
Maximum Motor NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower Rating GeneralPurpose Watertight Industrial - Dust-tight
NEMA Contin- Enclosure Enclosure Enclosure 1
1 1 1
Size 115V 200V 230V uous Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
00 1
/3 ---- 1 9 T13AA2A - * $ 348. Use size 0 $ Use Size 0 $ T13U02A - * $ 324.
0 1 ---- 2 18 T13AA20 - * 390. T13WA20 - * 910. T13TA20 - * 534. T13U020 - * 366.
1 2 ---- 3 27 T13AA21 - * 450. T13WA21 - * 882. T13TA21 - * 594. T13U021 - * 426.
1P 3 ---- 5 ---- T13AA2P - * 582. T13WA2P - * 1014. T13TA2P - * 726. T13U02P - * 558.
2 3 ---- 7 1/2 45 -------- ---- -------- ---- -------- ---- T13U022 - * 774.
3 Pole, Three Phase (requires 3 overload heaters)
NEMA 460- Contin-
Size 200V 230V 575V uous
00 1 1/2
1
1 /2 2 9 T13AA3A - * 348. Use size 0 Use Size 0 T13U03A - * 324.
0 3 3 5 18 T13AA30 - * 432. T13WA30 - * 852. T13TA30 - * 576. T13U030 - * 408.
1 7 1/2
1
7 /2 10 27 T13AA31 - * 492. T13WA31 - * 924. T13TA31 - * 636. T13U031 - * 468.
2 10 15 25 45 T13AA32 - * 972. T13WA32 - * 1836. T13TA32 - * 1236. T13U032 - * 852.
3 25 30 50 90 T13AA33 - * 1620. T13WA33 - * 2844. T13TA33 - * 1932. T13U033 - * 1380.
4 40 50 100 135 T13AA34 - * 3660. T13WA34 - * 5748. T13TA34 - * 4692. T13U034 - * 3156.
2 2 2 2
52 75 100 200 270 U13AA35 - * 8634. U13WA35 - * 11274. U13TA35 - * 11274. U13U035 - * 7710.
6 150 200 400 540 See Vacuum Contactors in Section A

Note:
1. Price includes starter complete with one N.O. contact on each contactor and 3 phase overload relay less heaters.
3
7
2. This unit replaces T77 (size 5) and is not interchangeable.
5 3. For Ambient Compensated overload see B37.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Engineering Data - see Page B50 24/60 or 24/50 -96
Replace the (*) with the suffix from Modifications - see Page B36 110-120/60 or 110/50 -76
coil table. Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B44 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B7


TM - NEMA Control AC Reversing Starters

AC Reversing Starters - Bulletin 6030 TM


3 Pole, Three Phase (requires 3 overload heaters)
Maximum Motor 2
NEMA 1 NEMA 4 NEMA 12 Open Type
Horsepower Rating GeneralPurpose Watertight Enclosure Industrial - Dust-tight Enclosure
NEMA 460- Enclosure Enclosure
1 1 1 1
Size 200V 230V 575V Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
00 1
1 /2
1
1 /2 2 T30AA3A - * $ 828. T30WA3A - * $ 1380. Use Size 0 $ T30U03A - * $ 780.
0 3 3 5 T30AA30 - * 972. T30WA30 - * 1524. T30TA30 - * 1188. T30U030 - * 924.
1 1
7 /2
1
7 /2 10 T30AA31 - * 1116. T30WA31 - * 1884 T30TA31 - * 1332. T30U031 - * 1044.
2 10 15 25 T30AA32 - * 2172. T30WA32 - * 3420. T30TA32 - * 2532. T30U032 - * 1980.
3 25 30 50 T30AA33 - * 3624. T30WA33 - * 5472. T30TA33 - * 4416. T30U033 - * 3288.
4 40 50 100 T30AA34 - * 8652. T30WA34 - * 11916. T30TA34 - * 9876. T30U034 - * 8028.
5 75 100 200 U30AA35 -3 * 19038. U30WA35 -3 * 21678. U30TA35 -3 * 21678. U30U035 -3 * 15426.
6 150 200 400 See Vacuum Contactors in Section A

Plug-Stop or Jogging Duty NEMA ICS 2-321-3


Horsepower Ratings - Three Phase
NEMA 200V 230V 380V 460/575V
Size 60 Hz 60 Hz 50 Hz 60 Hz
Note: 0 1 1/2 1 1/2 1 1/2 2
1. Includes starter complete with one N.O. contact on each contactor and 3 phase 1 3 3 5 5
overload relay less heaters. All starters are mechanically and electrically interlocked. 2 1
7 /2 10 15 15
2. For plug-stop or jogging duty or where operations exceed 5 per minute, starter 3 15 20 30 30
sizes should be chosen in accordance with NEMA Standard ICS 2-321-3, as listed in 4 25 30 50 60
table. 5 60 75 125 150
3. This unit replaces T77 (size 5) and is not interchangeable. 6 125 150 250 300 3
4. For Ambient Compensated overload see B37. 7
5

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Engineering Data - see Page B50 24/60 or 24/50 -96
Replace the (*) with the suffix from coil Modifications - see Page B36 110-120/60 or 110/50 -76
table. Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B45 550-600/60 or 550/50 -56
200-208/60 -86

B8 Discount Schedule JC10


AC Two Speed Starters NEMA Control - TM

AC Two Speed Non Combination Starters - Bulletin 6050


2 Speed, Single Winding (consequent pole)
Maximum Motor NEMA 1 NEMA 4 NEMA 12 Open Type
Horsepower Rating GeneralPurpose Watertight Industrial - Dust-tight
Constant or Variable Torque Enclosure Enclosure Enclosure
(Constant Horsepower)
NEMA 460- 1 1 1
1
Size 200V 230V 575V Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
3 3 5
0
(2) (2) (3)
T50AA0C2 - * $ 1848. T50WA0C2 - * $ 3000. T50TA0C2 - * $ 2220. T50UO0C2 - * $ 1800.
7 1/2 7 1/2 10
1
(5) (5) (7 1/2)
T50AA1C2 - * 1992. T50WA1C2 - * 3120. T50TA1C2 - * 2364. T50UO1C2 - * 1920.

10 15 25
2
(7 1/2) (10) (20)
T50AA2C2 - * 3624. T50WA2C2 - * 5016. T50TA2C2 - * 4152. T50UO2C2 - * 3408.

25 30 50
3
(20) (20) (40)
T50AA3C2 - * 5472. T50WA3C2 - * 7536. T50TA3C2 - * 6672. T50UO3C2 - * 5136.

40 50 100
4
(30) (40) (75)
T50AA4C2 - * 14616. T50WA4C2 - * 18840. T50TA4C2 - * 16992. T50UO4C2 - * 13296.

75 100 200
5 Consult Factory
(60) (75) (150)
2 Speed, Double Winding (separate winding)

3 3 5
0
(2) (2) (3)
T50AA0S2 - * 1320. T50WA0S2 - * 2472. T50TA0S2 - * 1692. T50UO0S2 - * 1272.
1
7 /2 7 1/2 10
1 1 T50AA1S2 - * 1488. T50WA1S2 - * 2616. T50TA1S2 - * 1860. T50UO1S2 - * 1416.
(50) (5) (7 /2)
10 15 25
2
(7 1/2 ) (10)
T50AA2S2 - * 2664. T50WA2S2 - * 4080. T50TA2S2 - * 3192. T50UO2S2 - * 2472.
(20)
25 30 50
3
(20) (20) (40)
T50AA3S2 - * 4176. T50WA3S2 - * 6240. T50TA3S2 - * 5376. T50UO3S2 - * 3840.

40 50 100
4
(30) (40)
T50AA4S2 - * 10248. T50WA4S2 - * 14472. T50TA4S2 - * 12624. T50UO4S2 - * 9624.
(75)
75 100 200
5 Consult Factory
3 (60) (75) (150)
8
0
Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All
starters are mechanically and electrically interlocked. Six (6) heaters are required, 3 for each speed rated for HP ratings.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Engineering Data - see Page B50 24/60 or 24/50 -96
Replace the (*) with the suffix from Modicications - see Page B36 110-120/60 or 110/50 -76
coil table. Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B46 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B9


TM - NEMA Control General Information
Combination Starters & Contactors

Non-Reversing
Bulletin 6018 with disconnect switch, fusible
and non-fusible.
Bulletin 6020 with Circuit Breaker 250V thermal
magnetic trip breaker or 600V adjustable
magnetic trip MCP. breaker.
B NEMA Size 0-6.
NEMA 1, 4 & 12 enclosures.
Choose standard, compact or extra-wide
enclosure style of enclosure for Sizes 0, 1 & 2.
All three styles are available in NEMA 1, 4 & 12
enclosure.
Sizes 3 & 4 are available in standard and extra-
wide enclosure styles.
Size 6 is supplied in the standard enclosure style
and includes Vacuum contactor.
Each starter includes disconnect device and TM
non-reversing starter.
Extensive field modification kits and factory
installed modifications are available.

Reversing
Bulletin 6038 with disconnect switch, fusible
and non-fusible.
Bulletin 6040 with circuit breaker.
250V thermal magnetic trip breaker or 600V
adjustable brip MCP. breaker.
NEMA Size 0-5.
NEMA 1, 4 & 12 Enclosures.
Each includes disconnect device and TM
reversing starter.
Extensive field modification kits and factory
installed modifications are available.

Multi-Speed
Bulletin 6058 with disconnect switch, fusible
and non-fusible.
Bulletin 6060 with Circuit Breaker.
600V MCP. breaker.
NEMA Size 0-6.
NEMA 1, 4 & 12 enclosures.
Each includes disconnect device and TM multi-
speed starter.
They are cataloged for two-speed, single winding
(consequent pole) and two speed, two
winding (seperate winding) motor application. 3

Starters for three and four speed motor 8


0
applications can also be supplied.
Extensive field modification kits and factory
installed modifications are available.

B10
General Information NEMA Control - TM
Combination Starters & Contactors
Disconnect Device Disconnect Operator
Disconnect switches are heavy duty, Flange mounted operating handle pro-
visible blade type with positive drive vides positive control of the disconnect.
action and meet industrial with stand Interlocking prevents opening the door
requirements.
with the disconnect "ON" or turning the
Above 100 amp., a non-automatic circuit
breaker with fuse clips is provided. disconnect "ON" with the door open.
Mounting plates include drilling for field Interlock defeaters are provided for
conversion of fuse size and spacing. maintance. B
Circuit breaker type starters use motor The position of disconnect is clearly
circuit protectors with a single, seven-point visible to determine if controller is "ON" or
trip adjustment and manual trip feature. An "OFF".
optional current limiter attachment provides A red handle flag is visible in the "ON"
200,000 amp. rms symmetrical interrupting state.
capacity.
Padlocking
Door Swing Operating handles can be padlocked in
The concealed hinge design allows 150o "OFF", with up to 3/8" shackle locks.
door swing for interior accessibility. Doors can be locked closed with one 3/8"
shackle lock, thus providing security to
Uniform Enclosure equipment and safety to personnel.
One enclosure covers Size 0, 1 & 2, for
each enclosure style. White Mounting Plate
Sizes 3 & 4 are covered by a single Baked ANSI safety white enamel is used
enclosure. for the mounting plate. This provides
NEMA 1, 4 & 12 enclosure designs are
increased visibility for safety.
each the same basic size, for each
enclosure style. All this for flexibility, ease
of layout and ease of installation. Add-On Accessories
Most TM starter add-on accessories can
be installed in combination starters.
Mounting plates are pre-drilled for field
Grounding installation of additional control devices.
A UL recommended type, green head
screw is provided for grounding the
enclosure. Quality Enclosure Construction
A green ground wire is installed in the Painted surfaces are baked enamel for
non-fused leg of control transformers. long life.
All unpainted hardware is plated for
corrosion resistance.
Door Gasketing
Hinge pins are stainless steel.
Standard on NEMA 4 & 12 and optional on
NEMA 1. Gasketing is neoprene, extruded, NEMA 4 enclosures are #304 stainless
closed cell type for increased life, sealing steel for appearance and corrosion
qualities and safety for the installer. resistance.

Safety & Relibility Space Savings


Flange mounted disconnect handle. Uniform enclosure sizes allow mixing NEMA starter sizes
Disconnect state clearly visible. in a row.
3 Defined enclosure grounding method.
8
Mount enclosures side-by-side, without restricted door swing.
Padlocking for both door and disconnect handle. Add most modifications without changing the enclosure.
0 Door swing for maximum interior accessories. Select an enclosure style for max. utilzation of available space.
All contribute to safety for the installer and for Minimize additional control enclosures by using the space in
operating personnel. an extra-wide starter enclosure.
Quality enclosure construction. Space saving economy is built into TM combination
Careful selection of disonnect devices and the starters.
basic TM starter all contribute to long, reliable
performance.

B11
TM - NEMA Control General Information

Choice of Enclosure Style


Choose from three enclosure styles, standard,
compact or extra-wide for non-reversing
starters through NEMA Size 2.
The compact style fits in low height areas and the
extra-wide has approximatley 200 square
inches inches of added panel space for mount-
B ing of auxiliary equipment.
Size 3 & 4 non-reversing starters are available
in standard and extra-wide.
Choice of enclosure style provides maximum
flexibility.

Versatility
Choose an enclosure style to meet the
application.
Check the enclosure sizes to simplify your
starter layouts.
Check the interchangeability of mounting
plates.
Choose add-on accessories for the basic TM
starter.
Select from a wide range of factory modifications
and field modification kits.
All of this to improve application flexibility with
minimum inventory requirements. This is the
versatility of TM combination starters.

Pilot Devices
A complete selection of field modification kits or
factory installed operator devices are
available.
Most are arranged for mounting on the enclo-
sure flange, eliminating the need for a flexible
wire harness to the door.

Control Transformer
Available factory installed or as a field modifica-
3
tion kit.
7
All starters can accommodate a 100VA extra
5
capacity transformer in every enclosure style
and type.
Secondary fusing standard.

B12
AC Combination Starters NEMA Control - TM

AC Combination Starters with Non-Fusible Disconnect Switch, 600V - Bulletin 6018


Standard - Vertical
Maximum Motor NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Switch GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460- Amps Rating Enclosure Enclosure
1 1 1
Size 200V 230V 575V Rating Amps. Catalog No. Price Catalog No. Price Catalog No. Price
0 3 3 5 18 30 T18AA30610 - * $ 1092. T18WA30610 - * $2244. T18TA30610 - * $ 1380.
1 7 1/2 7 1/2 10 27 30 T18AA31610 - * 1152. T18WA31610 - * 2304. T18TA31610 - * 1440.
2 10 15 25 45 60 T18AA32610 - * 1824. T18WA32610 - * 3600. T18TA32610 - * 2232.
3 25 30 50 90 100 T18AA33610 - * 3036. T18WA33610 - * 6132. T18TA33610 - * 3564.
4 40 50 100 135 150 -use extra wide- -use extra wide- -use extra wide-
5 75 100 200 270 400 Consult Factory
6 150 200 400 540 600
Compact - Horizontal
0 3 3 5 18 30 C18AA30610 - * 1092. C18WA30610 - * 2244. C18TA30610 - * 1380.
1 7 1/2 7 1/2 10 27 30 C18AA31610 - * 1152. C18WA31610 - * 2304. C18TA31610 - * 1440.
2 10 15 25 45 60 C18AA32610 - * 1824. C18WA32610 - * 3600. C18TA32610 - * 2232.
Extra Wide
0 3 3 5 18 30 E18AA30610 - * 1236. E18WA30610 - * 2736. E18TA30610 - * 1596.
1 7 1/2 7 1/2 10 27 30 E18AA31610 - * 1296. E18WA31610 - * 2796. E18TA31610 - * 1656.
2 10 15 25 45 60 E18AA32610 - * 1968. E18WA32610 - * 4092. E18TA32610 - * 2448.
3 25 30 50 90 100 E18AA33610 - * 3276. E18WA33610 - * 7092. E18TA33610 - * 3954.
4 40 50 100 135 150 E18AA34610 - * 5856. E18WA34610 - * 9816. E18TA34610 - * 7320.
3
8 Note:
0 1. Includes starter complete with N.O. contact and 3 phase overload relay less heaters.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Renewal Parts - see Page B42 24/60 or 24/50 -96
the (*) with the suffix from the coil Engineering Data - see Page B50 110-120/60 or 110/50 -76
table. Order Heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B13


TM - NEMA Control AC Combination Starters

AC Combination Starters with Fusible Disconnect Switch, 200-230V - Bulletin 6018


Standard - Vertical
Maximum Motor Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Amp. Rating GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Amp. Fuse 2 Enclosure Enclosure
1
Size 200V 230V Rating Switch Clips Catalog No. Price Catalog No. Price 1 Catalog No. Price 1

0 3 3 18 30 30 T18AA30203 - * $ 1128. T18WA30203 - * $ 2280. T18TA30203 - * $ 1416.


1 5 7 1/2 27 30 30 T18AA31203 - * 1188. T18WA31203 - * 2340. T18TA31203 - * 1476.
1 7 1/2 ---- 27 60 60 T18AA31206 - * 1212. T18WA31206 - * 2364. T18TA31206 - * 1500.
2 10 15 45 60 60 T18AA32206 - * 1872 T18WA32206 - * 3648. T18TA32206 - * 2280.
3 25 30 90 100 100 T18AA33201 - * 3156. T18WA33201 - * 6252. T18TA33201 - * 3684.
4 40 50 135 150 200 -use extra wide- -use extra wide- -use extra wide-
5 75 100 270 400 400
Consult Factory
6 150 200 540 600 600
Compact - Horizontal
0 3 3 18 30 30 C18AA30203 - * 1128. C18WA30203 - * 2280. C18TA30203 - * 1416.
1 5 7 1/2 27 30 30 C18AA31203 - * 1188. C18WA31203 - * 2340. C18TA31203 - * 1476.
1 7 1/2 ---- 27 60 60 C18AA31206 - * 1212. C18WA31206 - * 2364. C18TA31206 - * 1500.
2 10 15 45 60 60 C18AA32206 - * 1872. C18WA32206 - * 3648. C18TA32206 - * 2280.
Extra Wide
0 3 3 18 30 30 E18AA30203 - * 1272. E18WA30203 - * 2772. E18TA30203 - * 1632.
1 5 7 1/2 27 30 30 E18AA31203 - * 1332. E18WA31203 - * 2832. E18TA31203 - * 1692.
1 7 1/2 ---- 27 60 60 E18AA31206 - * 1356. E18WA31206 - * 2856. E18TA31206 - * 1716.
2 10 15 45 60 60 E18AA32206 - * 2016. E18WA32206 - * 4140. E18TA32206 - * 2496.
3 25 30 90 100 100 E18AA33201 - * 3288. E18WA33201 - * 7212. E18TA33201 - * 4074.
4 40 50 135 150 200 E18AA34202 - * 6060. E18WA34202 - * 10020. E18TA34202 - * 7524.

Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters. 5
2. Class R fuse clips available on request. 0
2

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Renewal parts - see Page B42 24/60 or 24/50 -96
Replace the (*) with the suffix from the Engineering Data - see Page B50 110-120/60 or 110/50 -76
coil table. Order Heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86

B14 Discount Schedule JC10


AC Combination Starters NEMA Control - TM

AC Combination Starters with Fusible Disconnect Switch, 460-575V - Bulletin 6018


Standard - Vertical
Maximum Motor Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Ampere Rating GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Ampere Fuse 2 Enclosure Enclosure
1 1 1
Size 460V 575V Rating Switch Clips Catalog No. Price Catalog No. Price Catalog No. Price
0 5 5 18 30 30 T18AA30603 - * $ 1152. T18WA30603 - * $ 2304. T18TA30603 - * $ 1440.
1 10 10 27 30 30 T18AA31603 - * 1212. T18WA31603 - * 2364. T18TA31603 - * 1500.
2 15 15 45 60 30 T18AA32603 - * 1884. T18WA32603 - * 3660. T18TA32603 - * 2292.
2 25 25 45 60 60 T18AA32606 - * 1908. T18WA32606 - * 3684. T18TA32606 - * 2316.
3 50 50 90 100 100 T18AA33601 - * 3216. T18WA33601 - * 6312. T18TA33601 - * 3918.
4 100 100 135 150 200 -use extra wide- -use extra wide- -use extra wide-
5 200 200 270 400 600 Consult Factory
Compact - Horizontal
0 5 5 18 30 30 C18AA30603 - * 1152. C18WA30603 - * 2304. C18TA30603 - * 1440.
1 10 10 27 30 30 C18AA31603 - * 1212. C18WA31603 - * 2364. C18TA31603 - * 1500.
2 15 15 45 60 30 C18AA32603 - * 1884. C18WA32603 - * 3660. C18TA32603 - * 2292.
2 25 25 45 60 60 C18AA32606 - * 1908. C18WA32606 - * 3684. C18TA32606 - * 2316.
Extra Wide
0 5 5 18 30 30 E18AA30603 - * 1296. E18WA30603 - * 2796. E18TA30603 - * 1656.
1 10 10 27 30 30 E18AA31603 - * 1356. E18WA31603 - * 2856. E18TA31603 - * 1716.
2 15 15 45 60 30 E18AA32603 - * 2028. E18WA32603 - * 4152. E18TA32603 - * 2508.
2 25 25 45 60 60 E18AA32606 - * 2052. E18WA32606 - * 4176. E18TA32606 - * 2532.
3 50 50 90 100 100 E18AA33601 - * 3456. E18WA33601 - * 7272. E18TA33601 - * 4134.
4 100 100 135 150 200 E18AA34602 - * 6108. E18WA34602 - * 10068. E18TA34602 - * 7572.

Note:
2 1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.
4 2. Class R fuse clips available on request.
1

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number Renewal Parts - see Page B42 24/60 or 24/50 -96
Replace the (*) with the suffix from the Engineering Data - see Page B50 110-120/60 or 110/50 -76
coil table. Order Heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B15


TM - NEMA Control AC Combination Starters

AC Combination Starters with Circuit Breaker, 200-230V - Thermal Magnetic Trip


Standard - Vertical, Bulletin 6020
Maximum Motor Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Breaker Thermal GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Ampere Ampere Magnetic Enclosure Enclosure
B Size 200V
2
230V
2
Rating Rating
15
Trip Catalog No.
T20AA30201 -
Price 1 Catalog No. Price 1
Catalog No.
T20TA30201 -
Price 1

0 18
* $ 1176.
T20WA30201 - * $ 2328. * $1464.
3 3 20 T20AA30202 - * T20WA30202 - * T20TA30202 - *
5 5 40 T20AA31203 - * T20WA31203 - * T20TA31203 - *
1 27 1236. 2388. 1524.
7 1/2 7 1/2 50 TEB T20AA31204 - * T20WA31204 - * T20TA31204 - *
10 10 50 T20AA32204 - * 1896.
T20WA32204 - * 3672.
T20TA32204 - * 2304.
2 45
15 15 70 T20AA32205 - * T20WA32205 - * T20TA32205 - *
25 25 100 T20AA33206 - * 3264.
T20WA33206 - * 6360.
T20TA33206 - * 3792.
3 90
30 30 150 T20AA33208 - * T20WA33208 - * T20TA33208 - *
TED
40 40 150 T20AA34208 - * 7164
T20WA34208 - * 11118.
T20TA34208 - * 8628.
4 135
----- 50 150 TEC T20AA34677 - * T20WA34677 - * T20TA34677 - *
50 ----- 200
5 60 60 270 225 TJK4 Consult Factory
75 100 300
Compact - Horizontal
2 2
18
15 C20AA30201 - *
1176.
C20WA30201 - * C20TA30201 - * 1464.
0 2328.
3 3 20 C20AA30202 - * C20WA30202 - * C20TA30202 - *
5 5
27
40 C20AA31203 - *
1236.
C20WA31203 - * C20TA31203 - * 1524.
1 TEB 2388.
7 1/2 7 1/2 50 C20AA31204 - * C20WA31204 - * C20TA31204 - *
2
10 10
45
50 C20AA32204 - *
1896.
C20WA32204 - * C20TA32204 - * 2304.
3672.
15 15 70 C20AA32205 - C20WA32205 - * C20TA32205 - *
Extra Wide
2 2 15 E20AA30201 - * E20WA30201 - * E20TA30201 - *
0 18 1320. 2820. 1680.
3 3 20 E20AA30202 - * E20WA30202 - * E20TA30202 - *
5 5 40 E20AA31203 - * E20WA31203 - * E20TA31203 - *
1 27 TEB 1380. 2880. 1740.
7 1/2 7 1/2 50 E20AA31204 - * E20WA31204 - * E20TA31204 - *
10 10
45
50 E20AA32204 - * 2040.
E20WA32204 - * 4164.
E20TA32204 - *
2 2520.
15 15 70 E20AA32205 - * E20WA32205 - * E20TA32205 - *
25 25
90
100 E20AA33206 - * 3504.
E20WA33206 - * 7320.
E20TA33206 - *
3 4182.
30 30 150 E20AA33208 - * E20WA33208 - * E20TA33208 - *
TED
4
40 40
135
150 E20AA34208 - * 7464.
E20WA34208 - * 12444.
E20TA34208 - *
9228.
----- 50 150 TEC E20AA34677 - * E20WA34677 - * E20TA34677 - *

Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.

Ordering Information Coil Volt/Hertz Suffix 3


8
Use complete catalog number. Replace the Renewal Parts - see Page B42 24/60 or 24/50 -96 0
(*) with the suffix from the coil table. Order Engineering Data - see Page B50 110-120/60 or 110/50 -76
heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86

B16 Discount Schedule JC10


AC Combination Starters NEMA Control - TM

AC Combination Starters with Circuit Breaker, 600V - Adjustable Magnetic Trip


Standard - Vertical, Bulletin 6020
Maximum Motor Starter Circuit Magnetic NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Breaker Trip Motor GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460/ Ampere Ampere Circuit Enclosure Enclosure
Size 200V 230V 575V
1
/2 1
/2 1
1 /2
Rating
18
Rating
3
Protector Catalog No.
T20AA30671 -
Price
*
1 Catalog No.
T20WA30671 - *
Price 1
Catalog No.
T20TA30671 - *
Price 1
B
0 1 1/2 1 1/2 3 18 7 T20AA30672 - * $1524. T20WA30672 - * $ 2676. T20TA30672 - * $1812.
3 3 5 18 15 T20AA30673 - * T20WA30673 - * T20TA30673 - *
1
1
/2 /2 1 1/2 27 3 T20AA31671 - * T20WA31671 - * T20TA31671 - *
1
1 1/2 1 1/2 3 27 7 T20AA31672 - * T20WA31672 - * T20TA31672 - * 1872.
TEC 1584. 2736.
3 3 5 27 15 T20AA31673 - * T20WA31673 - * T20TA31673 - *
7 1/2 7 1/2 10 27 30 T20AA31674 - * T20WA31674 - * T20TA31674 - *
2
7 1/2 7 1/2 10 45 30 T20AA32674 - * T20WA32674 - * T20TA32674 - * 2652.
2244. 4020.
10 15 25 45 50 T20AA32675 - * T20WA32675 - * T20TA32675 - *
3 25 30 50 90 100 T20AA33676 - * 3264. T20WA33676 - * 6360. T20TA33676 - * 3792.
4 40 50 100 135 150 T20AA34677 - * 7164. T20WA34677 - * 11124. T20TA34677 - * 8628.
5 75 100 200 270 400 TJC4 Consult Factory
Compact - Horizontal
1
/2 1
/2 1 1/2 18 3 C20AA30671 - * C20WA30671 - * C20TA30671 - *
0 1 1/2 1 1/2 3 18 7 C20AA30672 - * 1524. C20WA30672 - * 2676. C20TA30672 - * 1812.
3 3 5 18 15 C20AA30673 - * C20WA30673 - * C20TA30673 - *
1
/2 1
/2 1 1/2 27 3 C20AA31671 - * C20WA31671 - * C20TA31671 - *
1 1/2 1 1/2 3 27 7 TEC C20AA31672 - * C20WA31672 - * C20TA31672 - *
1 1584. 2736. 1872.
3 3 5 27 15 C20AA31673 - * C20WA31673 - * C20TA31673 - *
7 1/2 7 1/2 10 27 30 C20AA31674 - * C20WA31674 - * C20TA31674 - *
7 1/2 7 1/2 10 45 30 C20AA32674 - * C20WA32674 - * C20TA32674 - *
2 2244. 4020. 2652.
10 15 25 45 50 C20AA32675 - * C20WA32675 - * C20TA32675 - *
Extra Wide
1
/2 1
/2 1 1/2 18 3 E20AA30671 - * E20WA30671 - * E20TA30671 - *
0 1 1/2 1 1/2 3 18 7 E20AA30672 - * 1668. E20WA30672 - * 3168. E20TA30672 - * 2028.
3 3 5 18 15 E20AA30673 - * E20WA30673 - * E20TA30673 - *
1
1
/2 /2 1 1/2 27 3 E20AA31671 - * E20WA31671 - * E20TA31671 - *
1 1/2 1 1/2 3 27 7 E20AA31672 - * E20WA31672 - * E20TA31672 - *
1 1728. 3228. 2088.
3 3 5 27 15 E20AA31673 - * E20WA31673 - * E20TA31673 - *
TEC
7 1/2 7 1/2 10 27 30 E20AA31674 - * E20WA31674 - * E20TA31674 - *
7 1/2 7 1/2 10 45 30 E20AA32674 - * E20WA32674 - * E20TA32674 - *
2 2388. 4512. 2868.
10 15 25 45 50 E20AA32675 - * E20WA32675 - * E20TA32675 - *
3 25 30 50 90 100 E20AA33676 - * 3504. E20WA33676 - * 7320. E20TA33676 - * 4182.
4 40 50 100 135 150 E20AA34677 - * 7464. E20WA34677 - * 12444. E20TA34677 - * 9228.

Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.

3
8
0 Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace the Renewal Parts - see Page B42 24/60 or 24/50 -96
(*) with the suffix from the coil table. Order Engineering Data - see Page B50 110-120/60 or 110/50 -76
heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B17


TM - NEMA Control AC Combination Starters

AC Combination Reversing Starters with Disconnect Switch - Bulletin 6038


Fusible 200 & 230 Volt
Maximum Motor Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Ampere Rating GeneralPurpose Watertight Enclosure Industrial - Dust-tight
2
NEMA Dual Element Fuses Amps Fuse Enclosure Enclosure
B Size 200V 230V Rating Switch Clips Catalog No. Price
1
Catalog No. Price
1
Catalog No. Price
1

0 3 3 18 30 30 T38AA30203 - * $ 1824. T38WA30203 - * $ 3288. T38TA30203 - * $ 2232.


1 5 7 1/2 27 30 30 T38AA31203 - * 1944. T38WA31203 - * 3408. T38TA31203 - * 2352.
1 7 1/2 ---- 27 30 60 T38AA31206 - * 1968. T38WA31206 - * 3432. T38TA31206 - * 2376.
2 10 15 45 60 60 T38AA32206 - * 3240. T38WA32206 - * 3972. T38TA32206 - * 3768.
3 25 30 90 100 100 T38AA33201 - * 5352. T38WA33201 - * 9264. T38TA33201 - * 6048.
4 40 50 135 150 200 T38AA34202 - * 11292. T38WA34202 - * 16236. T38AA34202 - * 13200.
5 75 100 270 400 400 Consult Factory
Fusible 460 & 575 Volt
460V 575V
0 5 5 18 30 30 T38AA30603 - * 1848. T38WA30603 - * 3312. T38TA30603 - * 2256.
1 10 10 27 30 30 T38AA31603 - * 1968. T38WA31603 - * 3432. T38TA31603 - * 2376.
2 15 15 45 60 30 T38AA32603 - * 3252. T38WA32603 - * 5484. T38TA32603 - * 3780.
2 25 25 45 60 60 T38AA32606 - * 3276. T38WA32606 - * 5508. T38TA32606 - * 3804.
3 50 50 90 100 100 T38AA33601 - * 5424. T38WA33601 - * 9336 T38TA33601 - * 6120.
4 100 100 135 150 200 T38AA34602 - * 11340. T38WA34602 - * 16284. T38AA34602 - * 13248.
5 200 200 270 400 400 Consult Factory

Non-Fusible
Maximum Motor Starter NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Disconnect GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460/ Ampere Switch Enclosure Enclosure
Size 200V 230V 575V Rating Rating Catalog No. Price 1 Catalog No. Price 1 Catalog No. Price 1

0 3 3 5 18 30 T38AA30610 - * $ 1788. T38WA30610 - * $3252. T38TA30610 - * $2196.


1 7 1/2 7 1/2 10 27 30 T38AA31610 - * 1908. T38WA31610 - * 3372. T38TA31610 - * 2316.
2 10 15 25 45 60 T38AA32610 - * 3192. T38WA32610 - * 5424. T38TA32610 - * 3720.
3 25 30 50 90 100 T38AA33610 - * 5292. T38WA33610 - * 9204. T38TA33610 - * 5988.
4 40 50 100 135 150 T38AA34610 - * 11908. T38WA34610 - * 15732. T38TA34610 - * 12996.
5 75 100 200 270 400 Consult Factory

Notes:
1. Includes starter complete with N.O. contact, disconnect switch less fuses, and 3 phase overload relay less heaters.
2. Class R fuse clips are available on request.
4
2
0

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace the (*) Renewal Parts - see Page B42 24/60 or 24/50 -96
with the suffix from the coil table. Engineering Data - see Page B50 110-120/60 or 110/50 -76
Order heaters at $18 each. For Plugging and Jogging Service - Page B8 220-240/60 or 220/50 -26
Modifications - see Page B36 440-480/60 or 440/50 -46
Heater Tables - see Page B33 550-600/60 or 550/50 -56
Dimensions - see Page B48 200-208/60 -86

B18 Discount Schedule JC10


AC Reversing Starters NEMA Control - TM

AC Combination Reversing Starters with Thermal-Magnetic Trip, 240V - Bulletin 6040


Maximum Motor Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Breaker Thermal GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA
Size 200V 230V
Ampere
Rating
Ampere
Rating
Magnetic Enclosure
Trip Catalog No. Price
1
Catalog No. Price 1
Enclosure
Catalog No. Price 1 B
2 2 18 15 T40AA30201 - * T40WA30201 - * T40TA30201 - *
0 $ 1872. $ 3336. $ 2280.
3 3 18 20 T40AA30202 - * T40WA30202 - * T40TA30202 - *
5 5 27 40 T40AA31203 - * T40WA31203 - * T40TA31203 - *
1 2016. 3480. 2424.
7 1/2 7 1/2 27 50 TEB T40AA31204 - * T40WA31204 - * T40TA31204 - *
10 10 45 50 T40AA32204 - * T40WA32204 - * T40TA32204 - *
2 3384. 5616. 3912.
---- 15 45 70 T40AA32205 - * T40WA32205 - * T40TA32205 - *
25 25 90 100 T40AA33206 - * T40WA33206 - * T40TA33206 - *
3 5472. 9394. 6168.
25 30 90 150 TED T40AA33208 - * T40WA33208 - * T40TA33208 - *
40 40 135 150 T40AA34208 - * T40WA34208 - * T40TA34208 - *
4 12396. 17340. 14304.
---- 50 135 150 TEC T40AA34677 - * T40WA34677 - * T40TA34677 - *
50 ---- 270 200
5 60 60 270 225 TJC4 Consult Factory
75 100 270 300

AC Combination Reversing Starters with Motor Circuit Protector, 600V - Bulletin 6040
Maximum Motor Starter Circuit Magnetic NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Breaker Trip Motor GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460/ Amps Ampere Circuit Enclosure Enclosure
1 1 1
Size 200V 230V 575V Rating Rating Protector Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 18 3 T40AA30671 - * T40WA30671 - * T40TA30671 - *
0 1 1/2 1 1/2 3 18 7 T40AA30672 - * $2148. T40WA30672 - * $ 3612. T40TA30672 - * $2556.
3 3 5 18 15 T40AA30673 - * T40WA30673 - * T40TA30673 - *
1
/2 1
/2 1 1/2 27 3 T40AA31671 - * T40WA31671 - * T40TA31671 - *
1 1/2 1 1/2 3 27 7 T40AA31672 - * T40WA31672 - * T40TA31672 - *
1 * 2292. 3756. * 2700.
3 3 5 27 15 T40AA31673 - T40WA31673 - * T40TA31673 -
7 1/2 7 1/2 10 27 30 TEC T40AA31674 - * T40WA31674 - * T40TA31674 - *
7 1/2 7 1/2 10 45 30 T40AA32674 - * T40WA32674 - * T40TA32674 - *
2 * 3660. 5892. 4188.
10 15 25 45 50 T40AA62675 - T40WA62675 - * T40TA62675 - *
3 25 30 50 90 100 T40AA33676 - * 5472. T40WA33676 - * 9384. T40TA33676 - * 6168.
4 40 50 100 135 150 T40AA34677 - * 12396. T40WA34677 - * 17340. T40TA34677 - * 14304.
5 75 100 200 270 400 TJC4 Consult Factory

Note:
3
8
1. Includes starter with N.O. contact, circuit breaker and 3 phase overload relays less heaters.
0

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Modifications - see Page B36 24/60 or 24/50 -96
the (*) with the suffix from the coil table. Engineering Data - see Page B50 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Full-load Current Table - see Page B34 440-480/60 or 440/50 -46
Heater Tables - see Page B33 550-600/60 or 550/50 -56
Dimensions - see Page B48 200-208/60 -86

Discount Schedule JC10 B19


TM - NEMA Control AC Combination Starters

Non-Fusible AC 2 Speed Starter with Disconnect Switch, 200, 230, 460 and 575V
2 Speed, Single Winding (consequent pole), Bulletin 6058
Maximum Motor
B Horsepower Rating
Constant or Variable Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
Torque ( Constant Continue Switch GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Horsepower) 460- Ampere Ampere Enclosure Enclosure
1 1 1
Size 200V 230V 575V Rating Rating Catalog No. Price Catalog No. Price Catalog No. Price
3 3 5
0 18 30 T58AA0C2610 - * $2976. - use size 1 - * - use size 1 - *
(2) (2) (3)
7 1/2 7 1/2 10
1 27 30 T58AA1C2610 - * 3120. T58WA1C2610 - * $ 4968. T58TA1C2610 - * $ 3516.
(5) (5) (7 1/2 )
10 15 25
2 45 60 T58AA2C2610 - * 5064. T58WA2C2610 - * 7368. T58TA2C2610 - * 5688.
(7 1/2) (10) (20)
25 30 50
3 90 100 T58AA3C2610 - * 7296. T58WA3C2610 - * 11232. T58TA3C2610 - * 8664.
(20) (25) (40)
40 50 100
4 135 150 T58AA4C2610 - * 17136. T58WA4C2610 - * 23328. T58TA4C2610 - * 21048.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)

2 Speed, Double Winding (separate winding)

3 3 5
0 18 30 T58AA0S2610 - * 2448. - use size 1 - * - use size 1 - *
(2) (2) (3)
7 1/2 7 1/2 10
1 27 30 T58AA1S2610 - * 2616. T58WA1S2610 - * 4464. T58TA1S2610 - * 3012.
(5) (5) (7 1/2 )
10 15 25
2 45 60 T58AA2S2610 - * 4104. T58WA2S2610 - * 6432. T58TA2S2610 - * 4728.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T58AA3S2610 - * 6000. T58WA3S2610 - * 9936. T58TA3S2610 - * 7368.
(20) (25) (40)
40 50 100
4 135 150 T58AA4S2610 - * 12768. T58WA4S2610 - * 18960. T58TA4S2610 - * 16680.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)

3
8
0

Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All starters
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Engineering Data - see Page B50 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modification - see Page B36 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B49 550-600/60 or 550/50 -56
200-208/60 -86

B20 Discount Schedule JC10


AC Combination Starters NEMA Control - TM

Fusible AC 2 Speed Starter with Disconnect Switch, 200-230V - Bulletin 6058


2 Speed, Single Winding (consequent pole)
Maximum Motor
Horsepower Rating
Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
B
Constant or Variable
Torque ( Constant Continue Switch GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Horsepower) Ampere Ampere Enclosure Enclosure
1 1 1
Size 200V 230V Rating Rating Catalog No. Price Catalog No. Price Catalog No. Price
3 3
0
(2) (2)
18 30 T58AA0C2203 - * $3168. - use size 1 - * - use size 1 - *
7 1/2 7 1/2
1
(5) (5)
27 30 T58AA1C2203 - * 3312. T58WA1C2203 - * $ 5160. T58TA1C2203 - * $ 3708.
10 15
2
(7 1/2 ) (10)
45 60 T58AA2C2206 - * 5160. T58WA2C2206 - * 7464. T58TA2C2206 - * 5784.
25 30
3
(20) (25)
90 100 T58AA3C2201 - * 7920. T58WA3C2201 - * 11856. T58TA3C2201 - * 9288.
40 50
4
(30) (40)
135 150 T58AA4C2202 - * 18960. T58WA4C2202 - * 25152 T58TA4C2202 - * 22506.
75 100
5 270 400 Consult Factory
(60) (75)

2 Speed, Double Winding (separate winding)

3 3
0 18 30 T58AA0S2203 - * 2640. - use size 1 - * - use size 1 - *
(2) (2)
7 1/2 7 1/2
1 27 30 T58AA1S2203 - * 2808. T58WA1S2203 - * 4656. T58TA1S2203 - * 3204.
(5) (5)
10 15
2 45 60 T58AA2S2206 - * 4200. T58WA2S2206 - * 6528. T58TA2S2206 - * 4824.
(7 1/2) (10)
25 30
3 90 100 T58AA3S2201 - * 6624. T58WA3S2201 - * 10560. T58TA3S2201 - * 7992.
(20) (25)
40 50
4 135 150 T58AA4S2202 - * 14592. T58WA4S2202 - * 20784. T58TA4S2202 - * 18408.
(30) (40)
75 100
5 270 400 Consult Factory
(60) (75)

Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All
starters are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Engineering Data - see Page B50 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modification - see Page B36 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B42 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B49 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B21


TM - NEMA Control AC Combination Starters

Fusible AC 2 Speed Starter with Disconnect Switch, 600V - Bulletin 6058


2 Speed, Single Winding (consequent pole)
B Maximum Motor
Horsepower Rating
Constant or Variable Starter Disconnect NEMA 1 NEMA 4 NEMA 12
Torque ( Constant Continue Switch GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Horsepower) Ampere Ampere Enclosure Enclosure
1 1 1
Size 460V 575V Rating Rating Catalog No. Price Catalog No. Price Catalog No. Price
5 5
0
(3)
18 30 T58AA0C2603 - * $3168. - use size 1 - * - use size 1 - *
(3)
10 10
1 27 30 T58AA1C2603 - * 3312. T58WA1C2603 - * $ 5160. T58TA1C2603 - * $ 3708.
(71/2) (71/2)
15 15
2
(10)
45 60 T58AA2C2603 - * 5160. T58WA2C2603 - * 7464. T58TA2C2606 - * 5784.
(10)
25 25
2
(20)
45 60 T58AA2C2606 - * 5160. T58WA2C2606 - * 7464. T58TA2C2601 - * 5784.
(20)
50 50
3
(40)
90 100 T58AA3C2601 - * 7440. T58WA3C2601 - * 11376. T58TA3C2602 - * 9288.
(40)
100 100
4
(75)
135 200 T58AA4C2602 - * 17664. T58WA4C2602 - * 23856. T58TA4C2604 - * 22776.
(75)
5 200 200 270 400 Consult Factory
(150) (150)
2 Speed, Double Winding (separate winding)

5 5
0 18 30 T58AA0S2603 - * 2640. - use size 1 - * - use size 1 - *
(3) (3)
7 1/2 7 1/2
1 27 30 T58AA1S2603 - * 2808. T58WA1S2603 - * 4660. T58TA1S2603 - * 3204.
(5) (5)
10 15
2 45 30 T58AA2S2606 - * 4200. T58WA2S2603- * 6530. T58TA2S2603 - * 4820.
(7 1/2 ) (10)
25 25
2 45 60 T58AA3S2601 - * 4452. T58WA2S2606 - * 6530. T58TA2S2606 - * 4820.
(20) (20)
50 50
3 90 100 T58AA3S2602 - * 6624. T58WA3S2601 - * 10080. T58TA3S2601 - * 7510.
(40) (40)
100 100
4 135 200 T58AA4S2604 - * 14592. T58WA4S2602 - * 19490. T58TA4S2602 - * 17140.
(75) (75)

5 200 200 270 400


Consult Factory
(150) (150)

Note: 5
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All starters 0
2
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace Engineering Data - see Page B49 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modification - see Page B35 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B41 220-240/60 or 220/50 -26
Heater Tables - see Page B32 440-480/60 or 440/50 -46
Dimensions - see Page B42 550-600/60 or 550/50 -56
200-208/60 -86

B22 Discount Schedule JC10


AC Combination Starters NEMA Control - TM

AC 2 Speed Starters with Magnetic Trip Circuit Breaker, 200, 230, 460 and 575V
2 Speed, Single Winding (consequent pole), Bulletin 6060
Maximum Motor
Horsepower Rating Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Constant or Variable Torque Continuous Breaker GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA ( Constant Horsepower) Ampere Ampere Enclosure Enclosure
1 1
Size 200V 230V 460V/575V Ratings Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 1/2 1
1 18 3 T60AA0C2671 - * 3540. - use size 1 - - use size 1 -
1
( /4 ) ( /3 ) (1)
1 1
1 /2 1 /2 3
0 18 7 T60AA0C2672 - * 3540. - use size 1 - - use size 1 -
( 3/4 ) (1) (2)
3 3 5
18 15 T60AA0C2673 - * 3540. - use size 1 - - use size 1 -
(2) (2) (3)
1
1
/2 1
/2 1 /2
27 3 T60AA1C2671 - * 3684. T60WA1C2671 - * 5652. T60TA1C2671 - * 4080.
( 1/4 ) ( 1/3 ) (1)
1 1
1 /2 1 /2 3
3
/4 )
27 7 T60AA1C2672 - * 3684. T60WA1C2672 - * 5652. T60TA1C2672 - * 4080.
1 ( (1) (2)
3 3 5
27 15 T60AA1C2673 - * 3684. T60WA1C2673 - * 5652. T60TA1C2673 - * 4080.
(2) (2) (5)
1 1
7 /2 7 /2 10
27 30 T60AA1C2674 - * 3684. T60WA1C2674 - * 5652. T60TA1C2674 - * 4080.
(5) (5) (7 1/2 )
1 1
7 /2 7 /2 10
45 30 T60AA2C2674 - * 5688. T60WA2C2674 - * 7992. T60TA2C2674 - * 6312.
2 (5) (5) (7 1/2 )
10 15 25
45 50 T60AA2C2675 - * 5688. T60WA2C2675 - * 7992. T60TA2C2675 - * 6312.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T60AA3C2676 - * 7716. T60WA3C2676 - * 11652. T60TA3C2676 - * 9084.
(20) (25) (40)
40 50 100
4 135 150 T60AA4C2677 - * 18720. T60WA4C2677 - * 24816. T60TA4C2677 - * 22536.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)

Note:
1. Includes starter complete with N.O. contact, on each contactor, and two 3 phase overload relays less heaters. All starters
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
3
8
0

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number. Replace Engineering Data - see Page B49 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modification - see Page B35 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B41 220-240/60 or 220/50 -26
Heater Tables - see Page B32 440-480/60 or 440/50 -46
Dimensions - see Page B42 550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC10 B23


TM - NEMA Control AC Combination Starters

AC 2 Speed Starters with Magnetic Trip Circuit Breaker, 200, 230, 460 and 575V
2 Speed, Double Winding (Separate Winding), Bulletin 6060
Maximum Motor
Horsepower Rating Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Constant or Variable Torque ( Continuous Breaker GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Constant Horsepower) Ampere Ampere Enclosure Enclosure
1 1 1
Size 200V 230V 460V/575V Rating Ratings Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 1/2
1 1 18 3 T60AA0S2671 - * 3012. - use size 1 - - use size 1 -
( /4 ) ( /3 ) (1)
1 1/2 1 1/2 3
0 18 7 T60AA0S2672 - * 3012. - use size 1 - - use size 1 -
( 3/4 ) (1) (2)
3 3 5
18 15 T60AA0S2673 - * 3012. - use size 1 - - use size 1 -
(2) (2) (3)
1 1
/2 /2 1 1/2
27 3 T60AA1S2671 - * 3180. T60WA1S2671 - * 5028. T60TA1S2671 - * 3576.
( 1/4 ) ( 1/3 ) (1)
1 1/2 1 1/2 3
27 7 T60AA1S2672 - * 3180. T60WA1S2672 - * 5028. T60TA1S2672 - * 3576.
1 ( 3/4 ) (1) (2)
3 3 5
27 15 T60AA1S2673 - * 3180. T60WA1S2673 - * 5028. T60TA1S2673 - * 3576.
(2) (2) (5)
7 1/2 7 1/2 10
27 30 T60AA1S2674 - * 3180. T60WA1S2674 - * 5028. T60TA1S2674 - * 3576.
(5) (5) (7 1/2 )
7 1/2 7 1/2 10
1
/2 )
45 30 T60AA2S2674 - * 4728. T60WA2S2674 - * 7056. T60TA2S2674 - * 5352.
2 (5) (5) (7
10 15 25
45 50 T60AA2S2675 - * 4728. T60WA2S2675 - * 7056. T60TA2S2675 - * 5352.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T60AA3S2676 - * 6420. T60WA3S2676 - * 10356. T60TA3S2676 - * 7788.
(20) (25) (40)
40 50 100
4 135 150 T60AA4S2677 - * 14352. T60WA4S2677 - * 20478. T60TA4S2677 - * 18168.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)

Note:
1. Includes starter complete with N.O. contact, on each contactor, and two 3 phase overload relays less heaters. All starters
are mechanically electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
4
8
5

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number.Replace the Engineering Data - see Page 50 24/60 or 24/50 -96
(*) with the suffix from coil table. Order Modification - see Page 36 110-120/60 or 110/50 -76
heaters at $18 each. Renewal Parts - see Page 42 220-240/60 or 220/50 -26
Heater Tables - see Page 33 440-480/60 or 440/50 -46
Dimensions - see Page 49 550-600/60 or 550/50 -56
200-208/60 -86

B24 Discount Schedule JC10


AC Reduced Voltage Starters NEMA Control - TM

Auto Transformer Starter

Autotransformer Closed Transition


Reduced Voltage Starting of Squirrel Cage Motors
Highest Starting Torque per Ampere of Line Current
Available in Type 4 & 12 Enclosure B
All Disconnect Types Available
Complete Line Factory Installed Modifications

Two Step Part Winding

Part Winding Starters


Two Step Starting of Squirrel Cage Motors
Lowest Cost Method of Starting
NEMA Type 1, 4, & 12 Enclosures
Factory Installed Modifications

Open Transition Wye Delta Starter

Wye-Delta Starters
Available Open or Closed Transition
Inrush Current 1/3 Normal Line Starting
NEMA 1 Enclosure Standard
3
8
0

B25
TM - NEMA Control Reduced Voltage Starters
Autotransformer Closed Transition - Bulletin 6082
Max. Motor NEMA Type 1
2
Horsepower GeneralPurpose
NEMA Rating 1
Size 230V 460V Catalog No. Price
25 ----- T82AA3FB - * 9714.
30 ----- T82AA3GB - * 9714.
3
T82AA3GE - *
B -----
-----
30
50 T82AA3JE - *
10788.
10788.
50 ----- T82AA4JB - * 15516.
4
----- 100 T82AA4ME - * 15804.
75 ----- U2AA5LB - * 24690.
100 ----- U82AA5MB - * 26560.
5
----- 150 U82AA5PE - * 26690.
----- 200 U82AA5QE - * 28890.
125 -----
150 -----
200 -----
6 Refer to Section A
----- 250
----- 300
----- 400

Wye-Delta Starters 3, NEMA 1 Enclosures - Bulletin 6095


Wye Maximum Motor NEMA 1 General Purpose Enclosure
Delta Horsepower Rating Open Transition Closed Transition
Size 200 230 460/575 Catalog No. Price Catalog No. Price
10 ----- ----- T95AA30T1A T95AA3CT1A
1 ----- 10 ----- T95AA30T1B 4122. T95AA3CT1B 6294.
----- ----- 15 T95AA30T1C T95AA3CT1C
20 ----- ----- T95AA30T2A T95AA3CT2A 7050.
2 ----- 25 ----- T95AA30T2B 4700. T95AA3CT2B 7120.
----- ----- 40 T95AA30T2C T95AA3CT2C 7380.
40 ----- ----- T95AA30T3A T95AA3CT3A 9830.
3 ----- 50 ----- T95AA30T3B 7100. T95AA3CT3B 9830.
----- ----- 75 T95AA30T3C T95AA3CT3C 11120.
60 ----- ----- T95AA30T4A T95AA3CT4A 18800.
4 ----- 75 ----- T95AA30T4B 14880. T95AA3CT4B 19370.
----- ----- 150 T95AA30T4C T95AA3CT4C 20430.
150 ----- ----- V95AA30T5A V95AA3CT5A 32610.
5 ----- 150 ----- V95AA30T5B 26610. V95AA3CT5B 32610.
----- ----- 300 V95AA30T5C V95AA3CT5C 33400.
300 ----- -----
6 ----- 350 ----- Consult Factory
----- ----- 700

Note:
1. Maximum horsepower ratings are in accordance with NEMA Standards ICS2-321C:20. Auto transformers are 3-Coil type, with voltage taps at
50%, 65% and 80% rated in accordance with NEMA Standards ICS2-214.21 for medium-duty starting service.
0
2. Size 5 Starters are supplied in floor mounted enclosures without bottom cover plate for mounting against a wall. If not mounted against a wall, a 3
rear cover plate must be ordered. 3
3. Wye-Delta Starters Overload Relay Heater Selected by dividing FLC by 1.73 and select Heaters from index.

Ordering Information Coil Table


Use complete catalog number. each. Line Control
Replace the (*) with the suffix from Modifications see Page B36 Volt/60Hz Voltage Transformer
the Coil Table. Heaters are Engineering Data Page B50 220-240 -26 -T26
purchased seperately at $18 Renewal Parts Page B42 440-480 -46 -T46

B26 Discount Schedule JC23


Reduced Voltage Starters NEMA Control - TM

Part Winding Starters, Two Step - Bulletin 6090


Max. Motor Horsepower Type 1 Type 4 Type 12 Open Type U
Rating 2 or 3-Phase GeneralPurpose Watertight Industrial
Size 200V 230V 460/575V Poles Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
1 PW 10 10 15 T90AA31 - * $ 2628. T90WA31 - * $ 4068. T90TA31 - * $ 3828. T90U031 - * $ 2556.
2 PW 20 25 40 T90AA32 - * 3744. T90WA32 - * 5364. T90TA32 - * 5244. T90U032 - * 3552.
3 PW 40 50 75 3 T90AA33 - * 5280. T90WA33 - * 7620. T90TA33 - * 7080. T90U033 - * 4944.
4 PW 75 75 150 T90AA34 - * 11292. T90WA34 - * 14976. T90TA34 - * 13692. T90U034 - * 10668.
5 PW 150 150 350
Consult Factory
6 PW ---- 300 600

Note:
Includes starter complete with two contactors, timing device Overload Realy Heater Data
and two overload relays less heaters. (6 are required) Heater elements should be selected for running current in each
These starters are usually used with wye(star) connected winding. A total of 6 heater elements are required per controller.
motors. They may also be used for delta connected motors
when the motors are so designed that neither delta winding
need be open during starting.

4
0
0
Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace the Modifications see Page B36 24/60 or 24/50 -96
(*) with the suffix from the coil table. Renewal Parts see Page B50 110-120/60 or 110/50 -76
Order heater elements at $18 each. Engineering Data see Page B42 220-240/60 or 220/50 -26
440-480/60 or 440/50 -46
550-600/60 or 550/50 -56
200-208/60 -86

Discount Schedule JC23 B27


TM - NEMA Control Pump Control Panels

Fused Disconnect Switch, NEMA 3R - Bulletin 6318


200 & 230 Volts
Maximum Motor Horsepower Rating Starter Disconnect NEMA Type 3R
Continuous Ampere Rating Weatherproof
Dual Element Fuses Non-Time Delay Fuses
NEMA Ampere Fuse Enclosure
1
Size 200V 230V 200V 230V Rating Switch Clips Catalog No. Price

1
5 7 1/2 3 3 27 30
30 K18RB31203 - * $ 1530.
7 1/2 ----- ----- 7 1/2 60 K18RB31206 - * 1554.
2
10 15 ----- ----- 45 60
60 K18RB32206 - * 2070.
----- ----- 10 15 100 K18RB32201 - * 2214.
3
25 30 ----- ----- 90 100
100 K18RB33201 - * 3342.
----- ----- 25 30 200 K18RB33202 - * 3618.
4 40 50 ----- ----- 135 150 200 K18RB34202 - * 6258.
----- ----- 40 50 400 K18RB34204 - * 6846.
5 75 100 50 60 270 400 400 VK18RB350694 - * 13722.

460 & 575 Volts


Dual Element Fuses Non-Time Delay Fuses
460V 575V 460V 575V
10 10 7 1/2 7 1
/2
27 30 K18RB31603 - * $ 1554.
1 30
----- ----- 10 10 60 K18RB31606 - * 1578.
15 15 ----- ----- 45 30 K18RB32603 - * 2082.
2 60
25 25 15 20 60 K18RB32606 - * 2106.
50 50 30 40 90 100 K18RB33601 - * 3414.
3 100
----- ----- 50 50 200 K18RB33602 - * 3666.
100 100 60 75 135 200 K18RB34602 - * 6306.
4 150
----- ----- 100 100 400 K18RB34604 - * 6942.
5 200 200 125 150 270 400 400 VK18RB350694 - * 13722.

Note:
1. Includes Pump Control Panel in NEMA 3R weather-resistant enclosure, complete with integral circuit breaker or fusible
disconnect switch less fuses, start push button. Hand-Off-Auto selector switch and 3 phase ambient compensated overload
relay less heaters. Heaters are purchased separately at $9 each. For non ambient compensated overload relay delete "J"
4
from coil suffix. 8
5

Ordering Information Coil Volt/Hertz Suffix Coil Volt/Hertz Suffix


Use complete catalog number Replace the 24/60 or 24/50 -96J 380/50 -35J
(*) with the suffix from the coil table. 110-120/60 or 110/50 -76J 110/25 -12J
Order Heaters at $18 each. 220-240/60 or 220/50 -26J 220/25 -22J
Modifications see Page B36 440-480/60 or 440/50 -46J 440/25 -42J
Engineering Data see Page B50 550-600/60 or 550/50 -56J
Renewal Parts see Page B42 200-208/60 -86J

B28 Discount Schedule JC13


Pump Control Panels NEMA Control - TM

Circuit Breaker, 200, 230, 460 and 575V - Bulletin 6320


240 Volts Thermal Magnetic Trip
Maximum Motor Horsepower Rating Starter NEMA Type 3R
Continuous Circuit Breaker Weatherproof
NEMA Ampere Ampere Enclosure
1
Size 200V 230V 460/575V Rating Rating Type Catalog No. Price

1
52
5 2
----- 27
40 K20RB31203 - * $ 1580.
7 1/2 7 1/2 ----- 50
TEB K20RB31204 - * 1580.
2
10 10 ----- 45
50 K20RB32204 - * 2094.
----- 15 ----- 70 K20RB32205 - * 2094.
3
25 25 ----- 90
100 K20RB33206 - * 3462.
25 30 ----- 150
TED K20RB33208 - * 3462.
4 40 40 ----- 135 K20RB34028 - * 7362.
150
----- 50 ----- TEC K20RB34677 - * 7362.

600 Volts Adjustable Magnetic Trip M.C.P.


1
/2 1
/2 1 1/2 3 K20RB31671 - * $ 1962.
1 1 1/2 1 1/2 3 27 7 K20RB31672 - * 1962.
3 3 5 15 K20RB31673 - * 1962.
7 1/2 7 1/2 10 30 TEC K20RB31674 - * 1962.
2 7 1/2 7 1/2 10 45 30 K20RB32674 - * 2442.
15 15 25 50 K20RB32675 - * 2442.
3 25 30 50 90 100 K20RB33676 - * 3462.
4 40 50 100 135 150 K20RB34677 - * 7362.
5 75 100 200 270 400 TJC K20RB35679 - * 16782.
6 150 200 400 540 600 K20RB36680 - * 36366.

Note:
1. Includes Pump Control Panel in NEMA 3R weather-resistant enclosure, complete with integral circuit breaker or fusible disconnect switch
less fuses, start push button. Hand-Off-Auto selector switch and 3 phase ambient compensated overload relay less heaters. Heaters are
purchased separately at $9 each.

4 2. Specify HP if less than 5 HP


0
0

Ordering Information Coil Volt/Hertz Suffix


Use complete catalog number Replace the 24/60 or 24/50 -96J
(*) with the suffix from the coil table. Order 110-120/60 or 110/50 -76J
Heaters at $18 each. 220-240/60 or 220/50 -26J
Modifications see Page B36 440-480/60 or 440/50 -46J
Engineering Data see Page B50 550-600/60 or 550/50 -56J
Replacement Parts see Page B42 200-208/60 -86J

Discount Schedule JC13 B29


TM - NEMA Control Pump Panel Control
Factory Modifications For K18 & K20 Pump Panels
Catalog Additional Specify As
Description Add For NEMA Size Number Description Price Cat# Suffix
1 2 3 4 5 Suffix Control Circuit
Control Transformers Pilot Light, Standard Transformer Type,
Standard Capacity Red Lens $ 180 B
Primary Volts/Hertz: Fused Control Circuit (includes 2 Fuses) 264 C
220-240/60. or 220/50 — T26J Power Circuit
B 440-480/60. or 440/50
550-600/60. or 550/50
162 228 336 408 462 —

T46J
T56J Line Terminal Board, For Size 4 only.
252 D
220-208/60 — T86J 4/0 Aluminum Wire
380/50 — T35J Grounded Service Conductor Service
Entrance Lug For: NEMA Size 1-3 48 E
220/25 — T22J NEMA Size 4 60
246 342 504 612 612
440/25 — T42J Relays
Time Delay Relay (Pneumatic) 0.2 Seconds to
100 Watts Extra 3 Minutes Backspin (Includes Starter
220-240/60. or 220/50 — C26J Interlock) $1068 F
440-480/60. or 440/50 — C46J
288 372 468 528 588 Sequential Start timer 936 G
550-600/60. or 550/50 — C56J
200-208/60 — C86J
Lockout Control Relay 360 H
380/50 — C35J
Substitute Non-Ambient Compensated
Overload Relay 24 Remove J
220/25 — C22J
432 558 702 792 882 (Deduct) From
440/25
Suffix

ORDERING EXAMPLE Coil Suffix Table


K18RB34604 with 440/480 60 Hz . Std. Transformer,
Volts Hertz Suffix
Pilot Light (Options "B"), Grounded Service Entrance
Lug for size 4 (Option "E"), Backspin, Timer (Option "F") 110-120 60 -76
and Lockout Relay (Option "H"). 200-208 60 -86
Catalog # is K18RB34604 - T46J-B-E-F-H 220-240 60 -26
380 50 -35
List Price is $6942 + 816 + 180 + 60 + 1068 + 360
440-480 60 -46
Total Price $9426.
550-600 60 -56
Field Modifications Kits For Pump Panels
NEMA Catalog
NEMA Catalog Description Size Number Price
Description Size Number Price Power Circuit
Control Circuit Line Terminal Board For Size 4 A63-435540A $ 72.
Control Transformers -50/60 hz. 4 Only, 4/0 Aluminum Wire
50VA Capacity: 208V 1-2 KTR67-16 $216. Grounded Service Conductor 1-3 A63-435541A 24.
(Primary) 240V & 480V KTR67-2 Service Entrance Lug 4 A63-435542A 36.
600V KTR67-12 1-2 A63-435202A 48.
150V Capacity: 208V 1-2 KTR67-20 264. Load Terminals For 3 A63-435203A-1 46.
(Primary) 240V & 480V KTR67-5 Aluminum Wire 4 A63-435203A-2 86.
600V KTR67-22 Enclosure
250VA Capacity: 208V KTR67-23 342. Mounting Feet 1-2 A63-435370A-2 240.
(Primary) 240V & 480V 3-4 KTR67-7 3-4 A63-435370A-1 300.
600V KTR67-25 Relays
Pilot Lights With Red Lens 3
Time Delay Relay (Pneumatic), 1-4 713UPDE1 780.
7
120V A63-435538A-1 132. 0.2 Seconds To 3 Minutes: Plus KTM-10 60. 5
240V 1-4 A63-435538A-2 Backspin
480V A63-435538A-3 Sequential Start 1-4 713UP1 600.
600V A63-435538A-4 Lockout Control Relay 1-4 5SR1 168.
Fuse Block, 2 Pole, 30A, 250V, 1-4 A63-435539A 72. Discount Schedule JC80
Class H, With Two 1/2 A Dual Ambient Compensated 1 KTMA31-15 132.
ElementFuses Overload Relay 2 KTMA32-15 180.
Notes: 3 KTMA33-15 228.
1. To complete Cat. No. of relay, add coil suffix from Suffix Table 4 KTMA34-15 348.

B30 Discount Schedule JC 13


Thermal Overload Relays NEMA Controls - TM
Free Standing Panel Mount
Price & Catalog Numbers Bulletin 7324
Overload Normally Closed Normally Open & Normally
Relay Contacts Closed Contacts
Size Catalog No. Price 1 Catalog No. Price 1

Standard Bimetallic Overload Relays


1 -30AMP KTM31-12 $108. KTM31-13 $ 156.
2 -50AMP KTM32-12 156. KTM32-13 204. B
Ambient Compensated Bimetallic Overload Relays
1 -30AMP KTMA31-12 132. KTMA31-13 180.
2 -50AMP KTMA32-12 180. KTMA32-13 228.

1. Includes 3 - Phase Overload Relay complete, less heaters. Heaters


may be purchased at $18.00 each. See page B32.

Single Phase Application


A three phase overload relay is used
for single phase applications. Only Ambient Correction
one heater is required and is to be Not necessary when overload relay is ambient
installed in the center phase cavity of compensated as identified by green reset rod.
the relay. For control at an ambient constantly less than
the motor ambient, correct by decreasing the
Heater Selection nameplate motor full-load curent by 1% per oC
Select heaters based on motor namplate full- difference in ambient in ambient for heater
load current. Tables are for continuous rated selection.
motors. Full-load current for a given horse- For control at an ambient constantly greater
power motor will vary from one manufacturer than the motor ambient, correct by increasing
to another and will depend on RPM of motor. the nameplate motor full-load current by 1%
per oC difference in ambient.
Type Of Protection
Heaters selected directly from the table Branch Circuit Protection
provide a maximum of 125% protection at Branch circuit protection should be provided
40oC degree ambient, is suitable for motors per National Electric Code (USA) or the
with a 1.15 service factor with a 40oC degree Canadian Standards Asociation rules.
rise or less and with motor and controller at
the same temperature. Automatic Reset
For motors with a 1.0 service factor or with Automatic reset operation should not be used
a temperature rise greater then 40oC degree with two-wire control.
without service factor rating, use one size
smaller heaters than in table. The ultimate trip Overload Adjustment
of the heater is approximately 125% of the These overload relays are manufactured with
minimum current shown in the tables in a 40oC an exclusive calibration process to assure
degree ambient. the ultimate in tripping accuracy and
repeatability. The overload allows a true + 15%
adjustment as a result of the process and is
well suited for use with unity service factor
motors requiring a shorter locked rotor
tripping time. The + 15% adjustment is easliy
made by means of a small dial on the bottom of
the relay. A quick field modification also
permits removal of the adjustment feature.

Discount Schedule JC 14 B31


TM - NEMA Controls Thermal Overload Relays
Free Standing Panel Mounted Sizes 1 & 2-Type TM
Bimetallic Standard and Ambient Compensated

Motor Ampere Rating $18.00 List Each


Single Phase Three Phase
Heater One Heater 3 Heaters Overload
Catalog Relay
Number Min. Max. Min. Max. Size
2411 .58 .62 .46 .51
B 2412
2413
.63
.69
.68
.78
.52
.57
.56
.62
2414 .79 .88 .63 .70
2415 .89 .98 .71 .77
2416 .98 1.07 .78 .85
2417 1.08 1.21 .86 .96
2418 1.22 1.29 .97 1.02
2419 1.30 1.41 1.03 1.12
2420 1.42 1.49 1.13 1.18
2421 1.50 1.68 1.19 1.33 Bulletin 7324 Type TM Bimetallic Overload
2422 1.69 1.91 1.34 1.51 Relay 30 & 50 Ampere, Panel Mounting
2423 1.92 2.15 1.52 1.70
2424 2.16 2.49 1.71 1.97
2425 2.50 2.71 1.98 2.15
2426 2.72 2.99 2.16 2.37
2427 3.00 3.37 2.38 2.67
2429 3.38 3.67 2.68 2.89
2430 3.68 4.09 2.90 3.24 1 2
2431 4.10 4.53 3.25 3.51
2432 4.54 4.92 3.52 3.90
2433 4.93 5.30 3.91 4.25
2434 5.31 6.14 4.26 4.87
2435 6.15 6.89 4.88 5.48
2436 6.90 7.64 5.49 6.05
2437 7.65 8.19 6.06 6.50
2438 8.20 9.29 6.51 7.38
2439 9.30 10.1 7.39 8.07 O/L With
2441 10.2 10.7 8.08 8.55 N.C. Contact
2442 10.8 11.7 8.56 9.34
2443 11.8 12.6 9.35 10.0
2444 12.7 14.0 10.1 11.1
2445 14.1 16.2 11.2 12.8
2446 16.3 18.0 12.9 14.3
2447 18.1 20.7 14.4 16.4
2448 20.8 23.3 16.5 18.5
2450 23.4 25.4 18.6 20.0
2451 25.4 27.9 20.1 22.1
2452 28.0 32.9 22.2 26.1
2453 33.0 35.9 26.2 28.4
2454 36.0 40.6 28.5 30.0 O/L With N.C. And
2453 33.0 35.9 - - N.O. Contacts
2454 36.0 40.6 28.5 32.2
2455 40.7 45.5 32.3 36.1
2456 45.6 52.3 36.2 41.4
2457 52.4 58.0 41.5 47.9
2459 - - 48.0 50.0

Overload Relay Contact Ratings-Type TM

NEMA Continuous A-C Inductive (0.35pf)


Size Contact Volts,AC Am per es M a k e Break
120V or less 15A 1.5A
N.C. 120-600 V 1800VA 180VA
00-6 120V or less 2.5 3A .3A
N.O. 120-600V 360 VA 36 VA

B32 Discount Schedule JC16


Overload Heater Data NEMA Controls - TM
Type of Protection Ambient Correction Automatic Reset
Heaters selected directly from the table provide a Not necessary when overload relay is ambient Automatic reset operation should not be used
maximum of 125% protection at 40oC degree compensated as identified by green reset rod. with two-wire control.
ambient, is suitable for motors with a 1.15 service For control at an ambient constantly less than
Heater Selection
factor with a 40oC degree rise or less and with the motor ambient, correct by decreasing the
Select heaters based on motor nameplate
motor and controller at the same temperature. For namplate motor full-load curent by 1% per oC
full-load current. Tables are for continuous
motors with a 1.0 service factor or with a tempera- degree difference in ambient. For control at an
rated motors. Full-load current for a given
ture rise greater then 40oC degree without service ambient constantly greater than the motor
horsepower motor will vary from one
factor rating, use one size smaller heaters than in ambient, correct by increasing the nameplate
manufacturer to another and will depend on
table. The ultimate trip of the heater is approxi- motor full-load current by 1% per oC degree
RPM of motor.
mately 125% of the minimum current shown in the difference in ambient.
tables in a 40oC degree ambient. Three Phase - Size 00, 0, 1, 1P, 2 $18.00 List each B
Single Phase - Size 00, 0, 1, 1P, 2 $18.00 List each Motor Ampere Rating - Type TM, HP
Enclosed Starter
Motor Ampere Rating - Type TM, HP
Non-Ambient and
Enclosed Starter Open Starter Heater Open or Enclosed
Non-Ambient and Bimetallic Catalog Starters Ambient
Open Starter Heater Open or Enclosed Relay Number Compensated Relay
Bimetallic Catalog Starters Ambient
Min. Max. Min. Max.
Relay Number Compensated Relay
.44 .48 2411 .42 .46
Min. Max. Min. Max. .47 .51
.49 .54 2412
.55 .59 2411 .53 .57 .55 .59 2413 .52 .56
.60 .65 2412 .58 .63 .60 .67 2414 .57 .64
.66 .69 2413 .64 .67 .68 .73 2415 .65 .70
.70 .77 2414 .68 .75 .74 .81 2416 .71 .77
.78 .84 2415 .76 .82 .82 .91 2417 .78 .87
.85
.97
.96
1.06
2416
2417
.83
.94
.93
1.03
.92
.99
.98
1.07
2418
2419
.88
.94
.93
1.02
A
1.07 1.14 2418 1.04 1.11 1.08 1.16 2420 1.03 1.10
1.15 1.29 2419 1.12 1.25 1.17 1.27 2421 1.11 1.21
1.30 1.37 2420 1.26 1.33 1.28 1.44 2422 1.22 1.37
1.38 1.47 2421 1.34 1.43 1.45 1.63 2423 1.38 1.55
1.48 1.68 2422 1.44 1.63 1.64 1.88 2424 1.56 1.79
1.69 1.93 2423 1.64 1.87 1.89 2.05 2425 1.80 1.95
1.94 2.17 2424 1.88 2.11 2.06 2.26 2426 1.96 2.15
2.18 2.38 2425 2.12 2.31 2.27 2.55 2427 2.16 2.43
2.39 2.63 2426 2.32 2.55 2.56 2.76 2429 2.44 2.63
2.64 2.96 2427 2.56 2.87 2.77 3.10 2430 2.64 2.95
2.97 3.20 2429 2.88 3.11 3.11 3.35 2431 2.96 3.19
3.21 3.57 2430 3.12 3.47 3.36 3.75 2432 3.20 3.55
3.58 3.90 2431 3.48 3.79 3.76 4.06 2433 3.56 3.87
3.91 4.27 2432 3.80 4.15 4.07 4.64 2434 3.88 4.43
4.28 4.52 2433 4.16 4.39 4.65 5.23 2435 4.44 4.99
4.53 5.10 2434 4.40 4.95 5.24 5.79 2436 5.00 5.51
5.11 5.50 2435 4.96 5.34 5.80 6.20 2437 5.52 5.91
5.51 5.92 2436 5.35 5.75 6.21 6.96 2438 5.92 6.71
5.93 6.58 2437 5.76 6.39 6.97 7.71 2439 6.72 7.35
6.59 7.24 2438 6.40 7.03 7.72 8.15 2441 7.36 7.75
7.25 8.23 2439 7.04 7.99 8.16 8.79 2442 7.76 8.47
8.24 9.05 2441 8.00 8.79 8.80 9.65 2443 8.48 9.19
9.06 10.00 2442 8.80 9.75 9.66 10.6 2444 9.20 10.1
10.10 10.60 2443 9.76 10.3 10.7 12.2 2445 10.2 11.6
10.70 12.30 2444 10.4 11.9 12.3 13.7 2446 11.7 13.0
12.40 13.40 2445 12.0 13.0 13.8 15.7 2447 13.1 14.9
13.50 14.70 2446 13.1 14.3 15.8 17.6 2448 15.0 16.8
14.80 16.80 2447 14.4 16.3 17.7 19.1 2450 16.9 18.2
16.90 19.30 2448 16.4 18.7 19.2 20.9 2451 18.3 19.9
19.40 21.10 2450 18.8 20.5 21.0 24.3 2452 20.0 23.1
21.20 24.20 2451 20.6 23.5 24.4 26.0 2453 23.2 24.7
24.30 25.90 2452 23.6 25.0 26.1 29.3 2454 24.8 27.9
26.00 28.50 2453 25.0 27.1 29.4 31.4 2455 28.0 29.9
28.60 33.80 2454 27.2 31.9 31.5 34.8 2456 30.0 33.1
33.90 37.90 2455 23.0 35.9 34.9 40.1 2457 33.2 38.3
38.00 40.00 2456 36.0 38.9 40.2 43.6 2459 38.4 41.5
2457 39.0 40.0 43.7 45.0 2460 41.6 45.0

Discount Schedule JC16 B33


TM - NEMA Controls Overload Heater Data

B Three Phase Starter Overload Relay Heater


Table - Type TM - Sizes 3 & 4
Motor Ampere Rating $18.00 List Each
Enclosed Starter
Non-Ambient and
Open Starter Heater Open or Enclosed
Bimetallic Catalog Starters Ambient
Relay Number Compensated Relay
Min. Max. Min. Max.
7.5 8.2 2514 7.4 7.9
8.3 10.1 2515 8.0 9.9
10.2 10.8 2516 10.0 10.5
10.9 12.1 2517 10.6 11.9
12.2 13.7 2518 12.0 13.5
13.8 17.0 2519 13.6 16.7
17.1 19.2 2520 16.8 18.8
19.3 20.8 2521 18.9 20.3
20.8 23.2 2522 20.4 22.7
23.3 25.2 2523 22.8 24.7
25.3 29.1 2524 24.8 28.5
29.2 32.3 2525 28.6 31.6
32.4 36.0 2526 31.7 35.2
36.1 39.9 2527 35.3 39.1
40.0 43.4 2528 39.2 42.3
43.5 47.6 2529 42.4 46.4
47.7 52.4 2530 46.5 50.8
52.5 59.2 2531 50.9 57.3
59.3 66.0 2532 57.4 63.7
66.1 73.3 2533 63.8 70.7
73.4 80.4 2534 70.8 77.3
80.5 87.9 2535 77.4 83.1
88.0 95.0 2536 83.2 90.9
95.1 102.7 2537 91.0 97.6
102.8 111.9 2538 97.7 106.0
112.0 122.9 2539 106.1 115.4
123.0 133.9 2540 115.5 123.9
134.0 135.0 2541 124.0 135.0

B34 Discount Schedule JC16


Motor Full Load Current Data NEMA Controls - TM
The full load currents listed below are "average values" for motors of several manufacturers. These "average values" are as listed in the
National Electrical Code 1996 and must only be used as a guide for selecting suitable branch circuit components.

The rated full load current shown on the motor nameplate is likely to vary from the values listed below .
The NAMEPLATE full load current should always be used in determining the rating of devices.

When using a design "E" Motor Special considerations apply refer to NEC 1996 tables 430 -151A & B & 430-152, page 70-453/454.

B
FULL-LOAD MOTOR-RUNNING CURRENTS IN AMPERES
CORRESPONDING TO VARIOUS A.C. HORSEPOWER RATINGS

115 Volts 230 Volts 1 , 2 380 Volts 460 Volts 575 Volts 2.3 KV 4.16 KV

Single Three Single Three Single Three Single Three Single Three Three Three H.P.
Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase

1/10 -- -- -- -- -- -- -- -- -- -- -- --
1/8 -- -- -- -- -- -- -- -- -- -- -- --
1/6 4.4 -- 2.2 -- 1.40 -- -- -- -- -- -- --
1/4 5.8 -- 2.9 -- 1.85 -- -- -- -- -- -- --
1/3 7.2 -- 3.6 -- 2.32 -- -- -- -- -- -- --
1/2 9.8 4.4 4.9 2.2 3.19 1.28 2.5 1.1 2.0 0.9 -- --
3/4 13.8 6.4 6.9 3.2 4.47 1.78 3.5 1.6 2.8 1.3 -- --
1 16.0 8.4 8.0 4.2 5.12 2.30 4.0 2.1 3.2 1.7 -- --
1.5 20.0 12.0 10.0 6.0 6.38 3.32 5.0 3.0 4.0 2.4 -- --
2 24.0 13.6 12.0 6.8 7.66 4.34 6.0 3.4 4.8 2.7 -- --
3 34.0 -- 17.0 9.6 10.87 6.14 8.5 4.8 6.8 3.9 -- --
5 56.0 -- 28.0 15.2 17.90 9.71 14.0 7.6 11.2 6.1 -- --
7.5 80.0 -- 40.0 22.0 26.80 14.00 21.0 11.0 16.0 9.0 -- --
10 100.0 -- 50.0 28.0 33.20 17.90 26.0 14.0 20.0 11.0 -- --
15 -- -- -- 42.0 -- 26.80 34.0 21.0 27.0 17.0 -- --
20 -- -- -- 54.0 -- 34.50 44.0 27.0 35.0 22.0 -- --
25 -- -- -- 68.0 -- 43.50 55.0 34.0 44.0 27.0 -- --
30 -- -- -- 80.0 -- 51.20 68.0 40.0 54.0 32.0 -- --
40 -- -- -- 104.0 -- 66.50 88.0 52.0 70.0 41.0 -- --
50 -- -- -- 130.0 -- 83.10 108.0 65.0 86.0 52.0 -- --
60 -- -- -- 154.0 -- 103.0 -- 77.0 -- 62.0 16. 9.
75 -- -- -- 192.0 -- 128.0 -- 96.0 -- 77.0 20. 11.
100 -- -- -- 248.0 -- 165.0 -- 124.0 -- 99.0 26. 14.3
125 -- -- -- 312.0 -- 208.0 -- 156.0 -- 125.0 31. 17.
150 -- -- -- 360.0 -- 240.0 -- 180.0 -- 144.0 37. 20.
200 -- -- -- 480.0 -- 320.0 -- 240.0 -- 192.0 49. 27.
250 -- -- -- -- -- 403.0 -- 302.0 -- 242.0 60. 33.
300 -- -- -- -- -- 482.0 -- 361.0 -- 289.0 72. 40.
350 -- -- -- -- -- 560.0 -- 414.0 -- 336.0 83. 46.
400 -- -- -- -- -- 636.0 -- 477.0 -- 382.0 95. 52.
500 -- -- -- -- -- 786.0 -- 590.0 -- 472.0 118. 65.

5
NOTES:

1. To obtain F.L.C. for 200 and 208 Volt motors multiply 230 volts values by 1.15 and 1.10 respectively.

2. To obtain F.L.C. for 265 and 277 Volt motors multiply 230 Volt values by .87 and .83 respectively.

B35
TM - NEMA Control Factory Modifications
Modifications
Cover Controls
Enclosure Type
Add to NEMA
For Type Change
Bulletin Type Letter To:
Number Size 1 4 12 Typical Catalog Number

Overload Reset All Except 00-6 N/C O


N/C N/C
B Change from External to Internal
Push Buttons & Selector Switches
6031/7707

With External Reset:


6013,
Hand-Off-Auto Selector Switch B
6018,
Start-Stop Push Button 00-6 $ 96. $ 264. $264. C
6020,
With Internal Reset: 7707
Hand-Off-Auto Selector Switch E
Start-Stop Push Button F
With External or Internal Reset: All
2 or 3-Position Selector Switch-SPDT 6030-31, 96. 264. 264. B
Forward-Reverse-Stop Push Buttons 6038-40, 480. 480. 480. C
00-6
High-Low-Stop or Fast-Slow-Stop Push 6050-58,
6060 480. 480. 480. C
Buttons
Pilot Lights T 18 A A 3 1 6 0 3 - 46
Without Electrical Interlock:
180. 180. 180. 11
Standard Transformer Type, Red Lens
180. 180. 180. 12
Push-to-Test Transformer Type, Red Lens
With Electrical Interlock:
324. 324. 324. 13
Standard Transformer Type, Red Lens
All 00-6 504. 504. 504. 14
Push-to-Test Transformer Type, Red Lens
Standard Lens Color - Green —— N/C N/C 11+15
Blue —— N/C N/C 11+16
White —— N/C N/C 11+17
Yellow —— N/C N/C 11+18
Amber —— N/C N/C 11+19
Clear —— N/C N/C 11+20
Control Circuit
Contacts
Each- Extra N.O.( Contact Max 3 N/O or N/C) 132. 132. 132. 21
Contacts All 00-4
Each- Extra NC. (Contact Max 3 N/O or N/C) 132. 132. 132. 23

Mtd. on & operated by disconnect operator: 6018-20,


Single Pole, Double Throw 6038-40, 180. 180. 180. 24
Double Pole, Double Throw 6058-60 00-4 264. 264. 264. 25

Unwired Terminal Block, Use with Stranded Cu


Wire, #22- #10 AWG: 6018-20,
3 Wires Maximum 6038-40, 00-6 120. 120. 120. 27
6 Wires Maximum 6058-60 162. 162. 162. 28
Fused Control Circuit-2 Fuses Included 264. 264. 264. 29
Separate Control Circuit All N/C N/C N/C 30
4
9
Auxiliary Relays Type Enclosure Type: Change 2

Type Size 1 4 12 Letter To: Typical Catalog Number


Control Relay-4 Pole Maximum $612. $930. $652. 31
Timing Relay (Pneumatic) All 1008. 1320. 1008. 32
00-6
Compelling Relay 6050, 792. 792. 792. 33 T 18 A A 3 1 6 0 3 - 46
Auto. Acceleration Relay for each higher speed 6058, 1848. 1848. 1848. 34
Auto. Decelerating Relay for each higher speed 6060, 1848. 1848. 1848. 36
Brake Relay 1176. 1176. 1176. 37

B36 Discount Schedule JC 14


Factory Modifications NEMA Control - TM
Change
Cat. No.
For Character
Bulletin Encl. Add to NEMA Size
Indicated
Number Type To: Typical Catalog Number
Enclosure 0 1 2 3 4 5&6
Door Gasketing
Standard & Compact 6018-20 120. 120. 192. 264. 456. 792. 38
Extra-Wide 6018-20 All 216. 216. 312. 264. 456. 792. 39

All Enclosures 6038-40


6058-60
216. 216. 312. 264. 456. 396. 40 B
Engraved Indentification Plate All 1,4,12 80. 80. 80. 80. 80. 80.
Overload Relay T18AA31603-46 39

Ambient Compensated All Except All


Overload (Per Relay): 6031&7707 24. 24. 24. 24. 24. 24. 41
(SPDT) N.O. & N.C. Contacts (Per Relay) All Except All 48. 48. 48. 48. 48. 48. 43
Alarm Contact 6031&7707 1,4,12
Omit Overload Relay (Per Relay) All Except All (96.) (96.) (144.) (180.)(276.) (1444.) 44
( ) Deduct This $ Amount 6031&7707 1,4,12

Power Circuit
TECL Current Limiter Attachment for TEC 6020-40,
360. 360. 360. 960. 1950. N/A 45
Motor Circuit Protectors, 100,00 AIC Max. 6060
Class J Fuse Clips, In place of Class H 1,4,12
6018-38 9
Class R Fuse Clips, In place of Class H 6058 N/C N/C N/C N/C N/C N/C

Control transformer1
Description
Standard Capacity
Primary Volts/Hertz:
220-240/60, or 220/50 -T26
440-480/60, or 440/50 324. 324. 456. 672. 816. 924. -T46
550-600/60, or 550/50 -T56
200-208/60 -T86
372. 372. 612. 876. 1116. 1284. -T35
380/50
220/252 -T22
492. 492. 684. 1008. 1224. 1224.
440/252 -T42
100 Watts Extra
All 1,4,12
Primary Volts/Hertz:
220-240/60, or 220/50 -C26
440/480/60, or 440/50 -C46 T18AA31603-T46
550-600/60, or 550/50 576. 576. 744. 936. 1056. 1176. -C56
200-208/60 -C86
280/50 -C35
220/252 -C22
440/252 864. 864. 1116. 1404. 1584. 1764. -C42
Fused Primary (Includes 2 Fuses)
112. 112. 112. 112. 112. 112. 47
Ungrounded Secondary with 2 Dual
N/C N/C N/C N/C N/C N/C 48
ElementFuses
5
1 Special Voltage on Transformer (Not Std.)
2
Dual Voltage Secondary Add 10% to Price of Transformer 49

Notes:
UL Listed for field modification. Other modifications listed factory installed.
1. Single or Dual (200-240 & 440-480) Voltage primary with 110-120V secondary. Standard primary
voltages are 110-120, 200-205, 220-240, 277, 380, 440-480 and 550-600. Prices included 1 panel-
mounted, dual-element secondary fuse, with other side of secondary connected to cabinet ground.
2. Price includes extra-wide enclosure when used with any Bulletin 6018-20 starter.

Discount Schedule JC 14 B37


NEMA Control - TM Factory Modifications

Factory Installed Modifications For Reduced Voltage Starters


NEMA Size Cat.
Suffix
Special Enclosure 3 4 5 #
Add to NEMA 1 Enclosed Starter for: NEMA 4 Enclosure $3720. $6840. $6840. 61
(Note back & bottom cover plates are required for
B sizes 5 & 6.) NEMA 12 Enclosure 2280. 2880. 3240. 62
Disconnect Devices
Add to NEMA 1 Enclosed Starter for: NEMA 1 Enclosure 1824. 2520. 4512. 63
Non-Fusible Disconnect Switch NEMA 4 Enclosure 6856. 11328. 13320. 64
Combination NEMA 12 Enclosure 2136. 5736. 8232. 65
Add to NEMA 1 Enclosed Starter for: 100A Clips 1968.——— —— 66
Fusible Disconnect Switch NEMA 1 200A Clips 2448. 3048 —— 67
Combination Encl. 400A Clips 3384. 4344. 4944. 68
600A Clips —— 5676. 6636. 69
100A Clips 6600. —— —— 70
NEMA 4 200A Clips 7080. 11856. —— 71
Encl. 400A Clips 8016. 13152. 13752. 72
600A Clips —— 14484. 15444. 73
100A Clips 4416. —— —— 74
NEMA 12 200A Clips 4896. 6244. —— 75
Encl. 400A Clips 5832. 7560. 8664. 77
600A Clips —— 8892. 10356. 78
Add to NEMA 1 Enclosed Starter for : NEMA 1 Enclosure 2244. 4104. 7980. 79
Molded Case Circuit Breaker or NEMA 4 Enclosure 6876. 12912. 16788. 80
MCP Combination NEMA 12 Enclosure 4692. 7324. 11700. 81

Auxiliary Devices
T 82 A A 4JB—26
Control Relay (4 pole max.) NEMA 1 & 12 Encl. 612. 612. 612. 82
NEMA 4 Enclosure 936. 936. 936. 83
Pneumatic Timing Relay (3 min. max.) NEMA 1 & 12 Encl. 1008. 1008. 1008. 84
NEMA 4 Encl. 1320. 1320. 1320. 85
3 Phase Voltage Monitor Relay NEMA 1;4, & 12 Encl. 1152. 1152. 1152. 87
(Phase loss, Phase reversal, &
Undervoltage)
Ammeter & 1-Current Transformer 1680. 2376. 2376. 88
Ammeter, Switch & 3-Current Transformer 4440. 4440. 4440. 89
Voltmeter 2376. 2376. 2376. 90
Voltmeter & Switch NEMA 1,4 & 12 Encl. 3600. 3600. 3600. 91
Elasped Time Meter 696. 696. 696. 92
Wattmeter 4864. 4864. 4864. 93
Watthour meter 5040. 5040. 5040. 94
Convenience Recepticle Mounted on Side 240. 240. 240. 95
Cylinder Lock on Door 600. 600. 600. 96
Space Heater with N.C. Auxiliary
NEMA 1,4 & 12 Encl. 924. 1488. 2208. 97

B38 Discount Schedule JC 14


Field Modifications NEMA Control - TM
Modification Kits
Cover Control
For For
For Bulletin Mounting Enclosure NEMA
Description Number Location Type Size Kit Number Series A Price

Push Buttons Case 00-2 KTM-4 $ 60.


(Momentary) 00-2 KTM-33 60.
Start-Stop 6013 & 7707 Cover 1, 4 & 12
3&4 KTM4-38 96. B
0-2 KTM-5 KTM5-1 60.
6018-20 Flange 11
3&4 KTM-45 96.
00-2 KTM-183 KTM5-2 300.
Forward-Reverse-Stop 6030-31 Cover 1, 4 & 12
3&4 KTM4-51 360.
0-2 KTM-54 KTM5-2 300.
6038-40 Flange 11
3&4 KTM4-47 360.
Selector 00-2 KTM-73 60.
6013 & 7707 Cover 1, 4 & 12
Switches 3&4 KTM4-40 96.
(Maintained)2 6030-31-50 Case 1 00-2 KTM-8 60.
Case
Hand-Off-Auto 6018-20-38, 0-2 KTM-9 KTM5-3 60.
Flange 11
120V 6040-58-60 3&4 KTM4-43 96.
Pilot Lights 240V
120V KTM5-4 132.
(Include Red Lens) 480V
240V KTM5-5 132.
600V 00-2
480V KTM5-6 132.
120V 6013-30,
600V KTM5-7 132.
240V 6031-50, Cover 1, 4 & 12
120V
480V KTM5-4 180.
7707
240V
600V KTM5-5 180.
3&4
480V
120V KTM5-6 180.
600V
240V KTM5-7 180.
480V
120V KTM5-4 132.
600V
240V KTM5-5 132.
6018-20, 0-2
120V
480V KTM5-6 132.
240V 6038-40, Flange 11
120V Same As 180.
480V 6058-60
240V 3&4 Above 180.
600V
480V 180.
Reset Buttons 6013-30, KTM32-7
00-2 18.
(One Reset Per Kit) 6050 (2 Req)
6018-20-38-40, KTM32-19
0-2 24.
External Reset for NEMA Type 1, 4 & 12 6058-60 (2 Req)
Enclosed Standard Starters 6013-30, KTM34-8
Cover 1, 4 & 12 24.
6050 (2 Req)
3&4
6018-20-38-40, KTM34-19
6058-60 (2 Req) 24.
External Reset for #ETM032-1 & ETM031-1 3R KTM34-20
6013 00-2
NEMA Type 3R Enclosure 48.
External Reset - For use with Joslyn Clark panel mounted overload kits in NEMA 1, 4 & 12 Enclosures. Dimensions from outside surface of
enclosure cover to device mounting surface must fall in the range:
Starter Size 00, 0 & 1 . . . . . 5 7/8" -- 7 1/8"
Starter Size 1P & 2 . . . . . . . 6" -- 7 1/4" KTM32-8 36.
4
9
Panel Mtd. Overload . . . . .. 59/16"--613/16"
All Cover 1, 4 & 12 00-2
2

Reset Plug - Pack of 10 00-4 KTM-26 48.

Notes:

1. For Bulletins 6018, 6020, 6038, 6040, 6058, & 6060, NEMA 4 & 12 enclosed, use 30 mm. units.
2. Kits may be changed in the field from 3-position to 2-position operation. In addition to HAND-OFF-AUTO,
four labels are included, marked: FORWARD-OFF-REVERSE; HIGH-OFF-LOW; TEST-LAG-HEAD; ON-OFF.
3. Not suitable for enclosed starters with transformer.

Discount Schedule JC14 B39


TM-NEMA Control Field Modification
Enclosure Kits 1
For Use With NEMA Type 1 NEMA Type 4 NEMA Type 12
Bulletin No. Stainless Steel Industrial
of Open NEMA (General Purpose) (Watertight - Dust tight) Dust tight
Type Devices Size Kit Number Price Kit Number Price Kit Number Price
2 2 2
ETM012-1 $ 120. ETM042-1 $ 540. ETM122-1 $ 168.
00-2
6013 &7707 ETM012-2 192. ETM042-2 930. ETM122-2 384.
3&4 ETM014-1 240. ETM044-1 1110. ETM124-1 552.
2
ETM012-2 2
B 6030, 6031,
& 6050
00-2
ETM012-3
192.
312.
ETM042-2
------
930.
----
ETM122-2
------
2 384.
----
3&4 ETM014-2 336. ETM044-2 1830. ETM124-2 1128.
NEMA Type 3R
(Rainproof-Sleet Resistance)
6013-7707 00-1 ETM031-1 2&3 168.
6013-7707 2 ETM032-1 2&3 168.
Transformer Mounting Plate
Bulletin No. Use with Bulletin No. Use with
of Open NEMA Enclosure of Open NEMA Enclosure
Type Devices Size Kit No. Kit Numbers Price Type Devices Size Kit No. Kit Numbers Price
00-2 ETM012-2 KTM-28 $ 24. 7707-PM 20A KTM-80 $ 24.
ETM012-3
ETM014-1 00-2 KTM-29 24.
6013 & 7707 3&4 ETM044-1 KTM4-54 30. 6030-31 ETM014-2
ETM124-1 & 6050 3&4 ETM044-2 KTM4-55 60.
ETM124-2

Control Circuit Kits


Bulletin No. NEMA Size Kit Number Price
Auxiliary contacts for cavity mounting in starter and contactors. 00-4 KTM-10 $ 60.
One Normally Open, Convertible All TM 5 KTM35-10 60.
U5 KUM35-10 48.
One Normally Closed, Convertible 00-4 KTM-11 60.
All TM 5 KTM35-11 60.
U5 KUM35-11 48.
For side mounting on starters and contactors 00-2 KTM-20 120.
All
Two Normally Open, Non-Convertible 3-4 KTM-19 120.
Transformer Kits: Complete J Fused primary a midget single fused 120V secondary 4

VA Primary
Capacity Voltage Hertz Bulletin No. NEMA Size Kit Number Price
Standard 208 KTR67-16 $ 216.
Capacity - 50 240 & 480 KTR67-2 216.
Note: KTR67-12
600 5 216.
Can be used in NEMA 1, 4 & 12 00-2
100VA Extra 208 KTR67-20 264.
enclosures that have available space. See
Capacity - 150 240 & 480 50/60 All KTR67-5 264.
enclosure kits to determine those with
600 (See Note KTR67-22 264.
available space.
Standard 208 at Left) KTR67-23 342.
Capacity - 250 240 & 480 3&4 KTR67-7 342.
600 KTR67-25 342.
Accessories
6018-20-38,
Fuse Block, 2 Pole, 30 Amp., 250V, Class H, with two 1/2 Amp. Dual Element Fuses. 6040-58-60 0-2 KTM2-1 72.

Universal Starter Adaptor Kit. NEMA Size 1 Type TM starter with an assortment of 4
heaters, auxiliary contacts, and coils and A60-300999 adaptor plate. For rush and All 00-1 KTM-USA 1584.
9
2
emergency repairs; can replace most NEMA Size 00-1 starters

Notes:
1. For use with the listed open type devices. Each kit includes external "Reset" button(s) 2. Does not have space for transformer.
and "Reset" plug(s), either of which may be installed in the predrilled enclosure cover. 3. External "Reset" not included. For external "Reset", add Kit Number KTM32-20.
All enclosures have sufficient space to allow mounting a transformer or other equip- 4. Will not fit standard enclosures.
ment of similar size, unless otherwise noted. 5. Not applicable to NEMA 1 - Bulletin 6018, 6038 & 6058

B40 Discount Schedule JC 14


Field Modification Kits NEMA Control - TM
Power Circuit

Fuse Clips - Kit includes 6 clips and mounting screws,without base for lower clips. Bulletin No. NEMA Size Kit No. Kit No. Price
Fuse Switch If unit was If unit was
purchasedafter purchasedbefore
Class Amp. Size 1/1/98 1/1/98
30 amp. 250 volt (incl. 3 adaptor plates) H 0-2 KTMF-332* KTMF-332 $ 48.
30 amp. 600 volt & 60 amp. 250 volt H&J 30 & 60 KTMF-336* KTMF-336 48.
6018-38-58 KTMF-366* KTMF-366
60 amp. 600 volt H&J 1&2 72.
1 & 2 KTMF-312* KTMF-312
100 amp. 250 volt & 600 volt H 60 & 100 2&3 120.
Fuse Clip Lower Mounting Base - required only when converting a non-fusible starter to fusible or when
changing from 60 to 100 amp.30 & 60 amp. 250 & 600V 6018-38-58 2&3
2&3
00-2 KTMF-036*
KTMF-061*
KTMF-036
KTMF-061
60. B
00-2 96.
100 amp. 250 & 600 volt
* Add series letter from catalog # on the label on the door of Enclosure Series “A”, “B” or “C” A 2&3

Bulletin No. NEMA Size Kit No. Price


0&1 KTM41-1 132.
N.O. Type
1P & 2 KTM42-1 240.
Power Pole - Auxiliary pole for side-mounting 3 KTM43-1 300.
on starter or contactor. 4 KTM44-1 900.
All
0&1 KTM41-2 132.
NC. Type
1P & 2 KTM42-2 240.
3 KTM43-2 300.
4 KTM44-2 900.
Tie Pole - Auxiliary 4th & 5th power pole, both N.O. with 3-terminal connection 0&1 KTM51-1 264.
6050-58-60 2 KTM52-1 480.
for side-mounting on starter or contactors.
Power Take Off - For multiple sets of overload relays. 3 KTM53-1 600.
All 4 KTM54-1 1800.
Power Pole Insulator - Required when a power pole or tie pole is added to a 00-2 KTM32-6 72.
device in a 6 3/4" wide enclosure. 6013 & 7707 00-2 KTM-27 12.
Accessories
Cavity Cover (when auxiliary contact is not used) All 00-4 A77-300545 N/C
Adapter Plate - Used to enable replacement of competitive starters with type TM. 6013 00-2 A60-300999 18.
Adjusting Knob Wedges - Package of 25. Used in overload adjustment knob to
fix trip setting at 100%. All 00-2 KTM-25 12.

Heater Rack - Designed for stocking heaters for all TM starters. Rack has 25
compartments and will hold 900 of the #2400 series heaters or 600 of the #2500 ---- ---- KTM-99 390.
series heaters or a combination there of.

Figure Overall Dimensions - inches Enclosure


Number Height Width Depth Kit Number
1
10 /8 6 3
/4 6 7/16 ETM012-1
1 5
10 /8 12 /8 6 15/32 ETM012-2
1 14 1
/2 12 5
/8 6 4/8 ETM012-3
22 12 9 ETM014-1
3 1
24 /8 18 /2 9 ETM014-2
1
11 7 /4 6 15/32 ETM042-1
11 13 1
/8 6 15/16 ETM042-2
22 5
/8 12 1
/4 9 3/16 ETM044-1
26 3
/8 18 3
/4 9 3/16 ETM044-2
1
2 11 7 /4 6 15/32 ETM122-1
11 13 1
/8 6 15/16 ETM122-2
Enclosure 22 5
/8 12 1
/4 9 3/16 ETM124-1
3
Dimensions 26 3
/8 18 /4 9 3/16 ETM124-2
W B 11 7 1
/4 6 15/16 ETM031-1
1
NEMA 12 Enclosure Dimensions Modified for Outdoor Use 11 7 /4 6 15/16 ETM032-1
Joslyn Clark NEMA 12 enclosures may be field modified for outdoor use as follows: Starter
NEMA 3 Size Catalog Price
1. Watertight conduit hubs shall be used at all conduit entrances.
0&1 KTM042-11 $ 120.
NEMA 3R
2 KTM042-12 330.
1. Watertight conduit hubs shall be used at all conduit entrances when the
3 KTM044-13 354. Hubs for NEMA
conduit enters at a level higher than the lowest live part.
4 KTM044-14 676. Type 4 Enclosures
2. Drain holes of 1/8 inch diameter shall be added to the bottom of the enclosure.

Discount Schedule JC 14 B41


TM - NEMA Control Renewal Parts
For
NEMA Kit
Description of Kit Size Number Price
00,0,&1 KTM31-1 $ 212.
Power Contact Kit, For 3 Pole Type TM Starter Or Contactor (Movable And Stationary Contacts 1P,2 KTM32-1 345.
& Springs) 3 KTM33-1 909.
4 KTM34-1 1139.
5 KTM35-1 1863.
B Power Contact Kit, For 2 Pole TM5 Starter Or Contactor (Movable And
Stationary Contacts & Springs) 5 KTM25-1 1530.
Power Contact Kit, 1 Pole, For Type TM6 Starter or Contactor (Movable And Stationary
Contacts & Springs) 6 KTM16-1 2298.
(3 Required for 3 Pole Devices)

Power Contact Kit, For Type TM Normally Open Auxillary Side-mounted Power Pole on 1 & 2 0&1 KTM31-2 87.
Pole Starters And Contactors (1 Kit Required Per Pole-Movable And Stationary Contacts & 1P &2 KTM32-2 122.
Springs) 3 KTM43-1 345.
4 KTM44-1 1035.

Power Contact Kit, For Normally Closed Type TM Auxillary Side-mounted Power Pole 0,1,1P &2 KTM32-17 104.
(Movable And Stationary Contacts & Springs) 3 KTM43-2 345.
4 KTM44-2 1035.

Power Contact Kit, For Type TM Auxillary Side-mounted Tie Pole 2 REQD. 0&1 KTM32-17 $ 97.
(Movable And Stationary Contacts & Springs 1 REQD. 2 KTM32-18 221.
2 REQD. 3 KTM53-1 690.
2 REQD. 4 KTM54-1 2070.

Arc Shield Cover Kit (1 Required Per Power Pole) TM6 6 A77-434905A 863.

Replacement Overload Relay, Standard Bimetallic, Less Heaters, For Single Phase Type TM 00,0,1&1P KTM31-14 62.
Starter. Non Ambient Compensated

00,0,1 &1P KTM31-15 124.


Replacement Overload Relay, Non Ambient Compensated, Less Heaters, For 2 or 3 Phase 2 KTM32-15 179.
Type TM Starter 3 KTM33-15 235.
4 KTM34-15 373.
5&611 KTM35-13 152.
00,0 &1 KTMA31-15 152.
Replacement Overload Relay, Ambient Compensated, Less Heaters, For 2 or 3 Phase 1P &2 KTMA32-15 207.
Type TM Starter 3 KTMA33-15 262.
4 KTMA34-15 400.
5 &611 KTMA35-13 179.
Replacement Current Transformer Assembly, For Use with 5 A60-306547 1564.
KTM35-13 & KTMA35-13 Kits
Power Contact Kit, 3 Pole Type “U” Size 5 Starter or Contactor 5 KUM35-1 2330.
(Movable & Stationary Contacts & Springs)

For Replacement Parts For Size 6 Vacuum Contactors, refer to 6 ————— ——


Section A
2

4
Coil Part Numbers For Volts/Hertz
1
NEMA 110-120 200-208 220-240 277 380 440-480 550-600
Size Poles 110 220 440 550 Price
00-2 2-4 TB159-1 TB159-10 TB159-2 TB159-13 TB159-11 TB159-3 TB159-4 $ 124.
3 2-4 TB162-7 TB162-14 TB162-8 TB162-13 TB162-15 TB162-9 TB162-10 207.
4 2-4 TB162-1 TB162-16 TB162-2 TB162-18 TB162-17 TB162-3 TB162-4 248.
5 T Series 2-3 TB161-1 TB161-5 TB161-2 TB161-12 TB161-10 TB161-3 TB161-4 483.
61 T Series 2-3 TB163-1 TB163-5 TB163-2 TB163-7 TB163-6 TB163-3 TB163-4 476.
5 U Series 2-3 335L1 ————— 335L2 ————— ————— 335L3 335L4 225.
6 V Series Refer to Section A

B42 Discount Schedule JC 80


Dimensions NEMA Control - TM
NEMA Open Type, Type 1, 4 & 12 Magnetic Contactors
Open Type Dimensions - inches
NEMA Wide High Deep Mounting Open Type
Size Poles A B C D E
00 3 3 7/8 4 1/4 4 5
/8 3 3/4 1 1
/2
0-1 1-3 3 7/8 4 1/4 4 5
/8 3 3/4 1 1
/2
0-1 4 4 7/8 4 1/4 4 13
/16 3 3/4 1 1
/2
2
2
2-3
4
7
3 /8
4 7/8
4 1/4
4 1/4
4
4
15

15
/16
/16
3 3/4
3 3/4
1
1
1

1
/2
/2
B
7
3-4 2-3 5 /16 8 1/8 7 1
/16 6 7/8 3 1
/2
3-4 4 6 15/16 8 1/8 7 1
/16 6 7/8 3 1
/2
3
5 2-3 8 /4 12 1/4 9 1
/2 11 1/2 7
6 See Section A
NEMA Type 1
Type 1
00 3 6 3/4 9 1/2 6 1/4 7 3/4 5
0-2 1-4 6 3/4 9 1/2 6 1/4 7 3/4 5
3-4 2-4 12 22 9 19 9
5 2-3 22 49 11 3/8 47 1/2 18
6 See Section A
Type 1 (with transformer)
00 3 12 5/8 9 1/2 6 1/4 7 3/4 11
5 1 1
0-2 1-4 12 /8 10 /8 6 /4 9 1/2 11
3-4 2-4 12 22 9 19 9 NEMA Type 4
5 2-3 22 49 11 3/8 47 1/2 18
6 See Section A
Type 4
00 3 7 1/4 11 6 7/8 10 1/2 41
0-1 1-4 7 1/4 11 6 7/8 10 1/2 41
1 7
2 2-4 7 /4 11 6 /8 10 1/2 41
1 5 3
3 2-4 12 /4 24 /8 9 /16 23 1/2 71
1 5 3
4 2-4 12 /4 24 /8 9 /16 23 1/2 71
3
5 2-3 17 49 11 /8 47 1/2 18
6 See Section A
Type 4 (with transformer)
NEMA Type 12
1 7 1
00 3 13 /8 11 6 /8 10 /2 6
1 7 1
0-1 1-4 13 /8 11 6 /8 10 /2 6
1 7 1
2 2-4 13 /8 11 6 /8 10 /2 6
1
3 2-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
1
4 2-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
3 1
5 2-3 17 49 11 /8 47 /2 18
6 See Section A
Type 12
00 3 7 1/4 11 6 15
/16 10 1/2 41
0-2 1-4 7 1/4 11 6 15
/16 10 1/2 41
1 5 3
3-4 2-4 12 /4 24 /8 9 /16 23 1/2 71
3
5 2-3 22 49 11 /8 47 1/2 18
6 See Section A Conduit Hub Size and Location
Type 12 (with transformer) Enclo. Top & Bottom
Size Bottom Only H J K
00 3 13 1/8 11 6 15/16 10 1
/2 6 3
/4 3
/4 3 1 5/8 1 5/8
00-1
0-2 1-4 13 1/8 11 6 15/16 10 1
/2 6 3
/4 3 1 5/8 1 5/8
2 1 1/2
3-4 2-4 12 1/4 24 5/8 9 3/16 23 1
/2 71 3
/4 3 2 2
3 2
5 2-3 22 49 11 3/8 47 1
/2 18
4 2 1/2 3
/4 3 2 2
6 See Section A 5 3 3
5 3 3
/4
1
One top mtg. keyhole on center line.

B43
TM - NEMA Control Dimensions
NEMA Open Type, Type 1, 4 & 12
Open Type Dimensions - inches AC Magnetic Starters
NEMA Wide High Deep Mounting
Size Poles A B C D E Open Type Size 5
7
00 2-3 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
0-1 1-3 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
0-1 4 4 /8 6 5 3/16 5 1
/2 2 1
/2
7
1P 2 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
2 2-3 3 /8 6 5 3/16 5 1
/2 2 1
/2

B 2
3-4
4
3
4
5
7
/16
15
/16
6
11
5 3/16
7 1/16
5
9
1

3
/2
/4
2
3
1

1
/2
/2
7
3-4 4 6 /8 11 7 1/16 9 3
/4 3 1
/2
1
5 3 10 /8 15 7/8 9 5/8 13 1
/2 6 3
/8
6 See Section A
Type 1
00 2-3 6 3/4 9 1/2 6 1/4 7 3
/4 5
0-2 2-4 6 3/4 9 1/2 6 1/4 7 3
/4 5
1P 2 6 3/4 9 1/2 6 3/4 7 5
3-4 3-4 12 22 9 19 9
5 3 72 49 11 3/8 47 1
/2 18 NEMA Type 1 — Size 5
6 See Section A NEMA Type 1 — Sizes 00 to 4
Type 1 (with transformer)
5
00 2-3 12 /8 9 1/2 6 1
/4 7 3
/4 11
5 1 1 1
0-2 2-4 12 /8 10 /8 6 /4 9 /2 11
5
1P 2 12 /8 10 1/8 6 1/4 9 1
/2 11
3-4 3-4 12 22 9 19 9
5 3 22 49 11 3/8 47 1
/2 18
6 See Section A
Type 4
1 7 1
00 2-3 7 /4 11 6 /8 10 /2 41
1 7 1
0-1 2-4 7 /4 11 6 /8 10 /2 41
1 7 1
1P 2 7 /4 11 6 /8 10 /2 41
1 7 1
2 3-4 7 /4 11 6 /8 10 /2 41
1
3 3-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
1
4 3-4 12 /4 24 5/8 9 3/16 23 1
/2 7 NEMA Type 4 NEMA Type 12
5 3 17 49 11 3/8 47 1
/2 18
6 See Section A
Type 4 (with transformer)
1
00 2-3 13 /8 11 6 5/16 10 1
/2 6
1
0-2 2-4 13 /8 11 6 5/16 10 1
/2 6
1
1P 2 13 /8 11 6 5/16 10 1
/2 6
1
2 3-4 13 /8 11 6 5/16 10 1
/2 61
1
3 3-4 12 /4 24 5/8 9 3/16 23 1
/2 71
1 5
4 3-4 12 /4 24 /8 9 3/16 23 1
/2 7
5 3 17 49 11 3/8 47 1
/2 18
6 See Section A
Type 12
1
00 2-3 7 /4 11 6 15/16 10 1/2 41
1
0-2 2-4 7 /4 11 6 15/16 10 1/2 41
1
1P 2 7 /4 11 6 15/16 10 1/2 41 Conduit Hub Size and Location
1
3-4 3-4 12 /4 24 5/8 9 3/16 231/2 7 4
5 3 22 49 11 3/8 47 1/2 18 Enclo. Top & Bottom 9
2
6 See Section A Size Bottom Only H J K
3 3
00-1 /4 /4 3 1 5/8 1 5/8
Type 12 (with transformer)
2 1
1 /2 3
/4 3 1 5/8 1 5/8
1
00 2-3 13 /8 11 6 15/16 10 1
/2 6 3 2 3
/4 3 2 2
1
0-2 2-4 13 /8 11 6 15/16 10 1
/2 6 4 2 1/2 3
/4 3 2 2
1
1P 2 13 /8 11 6 15/16 10 1
/2 61 5 3 3 5 3 3
1 5
/4
3-4 3-4 12 /4 24 /8 9 3/16 23 1
/2 7
5 3 22 49 11 3/8 47 1
/2 18 Note:
6 See Section A 1. One top mtg. keyhole on center line.

B44
TM - NEMA Control Dimensions
NEMA Open Type, Type 1, 4 & 12 Reversing Starters & Contactors
Open Type Dimensions - inches
NEMA Wide High Deep Mounting
Size Poles Fig. A B C D E E1
00 3 8 3/16 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
0-1 3 8 3/16 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
0-1 4 9 3/116 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
2
2
3
4 1
8 3/16
9 3/16
4 1/4
4 1/4
4 3/4
4 3/4
3 3/4
3 3/4
6 13/16
6 13/16
4 5/16
4 5/16
B
3-4 3 11 5/16 8 1/8 7 1/16 6 7/8 9 3/8 5 7/ 8
3-4 4 14 15/16 8 1/8 7 1/16 6 7/8 9 3/8 5 7/8
5 3 19 3/4 16 1/4 10 1/8 15 1/2 17 1/16
5 3 Starter Refer Factory
6 See Section A
Type 1 Contactors and Starters
5
00 3 5 12 /8 9 1/2 6 1/4 7 3/4 11 *
5
0-2 3-4 5 12 /8 9 1/2 6 1/4 7 3/4 11 *
1
3-4 3-4 5 18 /2 25 3/4 9 23 16 16
5 3 6 22 49 9 3/8 47 1/2 18
6 See Section A
Type 1 (with transformer) Contactors and Starters

00 3 5 12 5/8 13 7/8 6 1/4 12 3


/4 11 *
0-2 3-4 5 12 5/8 13 7/8 6 1/4 12 3
/4 11 *
3-4 3-4 5 18 1/2 25 3/4 9 23 1
/2 16 16
5 3 6 22 49 9 3/8 47 1
/2 18
6 See Section A
Type 4 Contactprs and Starters

00 3 13 1/8 11 6 7/8 10 1
/2 6 6
1
0-2 3-4 13 /8 11 6 7/8 10 1
/2 6 6
3 3-4 18 3/4 28 3/8 9 3/16 27 1
/4 13 13
3 3
4 3-4 7 18 /4 28 /8 9 3/16 27 1
/4 13 13
5 3 25 37 1/2 10 1/2 36 11
6 See Section A
Type 4 (with transformer) Contactors and Starters
7
00 3 8 17 13 6 /8 9 16 16
7
0-2 3-4 8 17 13 6 /8 9 16 16
3 3-4 7 18 3/4 28 3/8 9 3
/16 27 1/4 13 13
4 3-4 7 18 3/4 28 3/8 9 3
/16 27 1/4 13 13
5 3 7 25 37 1/2 10 1
/2 36 11
6 See Section A
Type 12 Contactors and Starters
1
00 3 13 /8 11 6 15/16 10 1
/2 6 6
1
0-2 3-4 13 /8 11 6 15/16 10 1
/2 6 6
3
3-4 3-4 7 18 /4 23 3/8 9 3/16 27 1
/2 13 13
5 3 22 49 11 3/8 47 1
/2 18
6 See Section A Steel Enclosure
Type 12 (with transformer) Contactors and Starters NEMA Type 12 — No Hub Provisions
7
00 3 8 17 13 6 /8 9 6 6
0 7
0-2 3-4 8 17 13 6 /8 9 6 6
1
3-4 3-4 7 18 3/4 28 3/4 9 3
/16 27 1/4 13 13 Conduit Hub Size and Location
3
5 3 7 22 49 11 3
/8 47 1/2 18 Enclo. Top & Bottom
6 See Section A Size Bottom Only H J K
3 3
00-1 /4 /4 3 1 /85
1 5/8
2 1 1/2 3
/4 3 1 5/8 1 5/8
Note:
3 2 3
/4 3 2 2
1. One top mtg. keyhole on center line.
4 2 1/2 3
/4 3 2 2
5 3 3
/4 5 3 3

B45
TM - NEMA Control Dimensions
AC Non-Reversing 2 Speed Starters
Dimensions-Inches Mounting
NEMA Wide High Deep
Open Type
Size Fig. A B C D E1 E F
Open type - 2 Speed, Single Winding
00-2 1 9 3/16 6 5 5/16 5 1/2 4 5/16 6 3/16 1
/4
3-4 13 5/16 11 7 1/16 9 3/4 5 7/8 9 3/8 5
/16
B Open type - 2 Speed, Double Winding

00-2 1 8 3/16 6 5 5/16 5 1/2 4 5/16 6 15


/16 1
/4
5 1 3 7 3 5
3-4 11 /16 11 7 /16 9 /4 5 /8 9 /8 /16
Type 1 - 2 Speed, Single Winding
5 1
00-2 2 12 /8 9 /2 6 3/4 7 3/4 4 5
/16 6 13
/16 1
/4
3-4 18 1/2 25 3
/4 9 23 5 7/8 9 9
/8 5
/16
Fig. 1
Type 1 - 2 Speed, Single Winding (with transformer)

00-2 2 12 5/8 13 7/8 6 1/4 12 3/4 1 11 7


/8
3-4 18 1/2 25 3/4 9 23 16 16 1 3/8
Type 1 - 2 Speed, Double Winding
00-2 2 12 5/8 9 1/2 6 1/4 12 3/4 1 11 7
/8
1 3
3-4 18 /2 25 /4 9 23 16 16 1 3/8
Type 1 - 2 Speed, Double Winding (with Transformer)

00-2 2 12 5/8 13 7/8 6 1/4 12 3/4 1 11 7


/8 Fig. 2
3-4 18 1/2 25 3/4 9 23 16 16 1 3
/8
Type 4 - 2 Speed, Single Winding 3
00-1 3 13 1/8 11 6 5
/16 10 1/2 6 6 1
/4
2 13 1/8 11 6 5
/16 10 1/2 6 6 1
/4
3 18 3/4 28 3/8 9 3
/16 27 1/4 13 13 9
/16
4 18 3/4 28 3/8 9 3
/16 27 1/4 13 13 9
/16
Type 4 - 2 Speed, Single Winding (with transformer) 3
7
00-1 3 15 13 6 /8 9 16 16 2
7
2 15 13 6 /8 9 16 16 2
3 18 3/4 28 3/8 9 3
/8 27 1/4 13 13 9
/16
4 18 3/4 28 3/8 9 3
/16 27 1/4 13 13 9
/16
Type 12 - 2 Speed, Single Winding
00-2 4 13 1/8 11 6 15/16 10 1/2 6 6 1
/4
3-4 18 3/4 28 3/8 9 3/16 27 1/4 13 13 9
/16
Type 12 - 2 Speed, Single Winding (with transformer)
00-2 4 15 13 6 7/8 9 16 16 1
/4
3
3-4 18 /4 28 3/8 9 3/16 27 1/4 13 13 9
/16
Type 12 - 2 Speed, Double Winding NEMA Type 4
00-2 4 13 1/8 11 6 15
/16 10 1/2 6 6 1
/4
3-4 18 3/4 28 3
/8 9 3
/16 27 1/4 13 13 9
/16
Type 12 - 2 Speed, Double Winding (with transformer)
1 4
00-2 4 13 /8 11 6 5/16 10 1/2 6 6 1
/4 9
3 3
3-4 18 /4 28 /8 9 3/16 27 1/4 13 13 9
/16 2

Notes:
1. Indicates mounting hole is on the center line of enclosure.
2. For NEMA size 5 refer to factory.
3. NEMA Type 4 includes conduit hubs. NEMA Type 12-No Hub Provisions

B46
Dimensions NEMA Control - TM
Combination Starters

Compact Style
Standard or Extra-Wide Style NEMA 1
NEMA 1 Conduit
Standard or Extra-Wide Style
Hub
NEMA 4 & 12

NEMA 4 Hub
Application Table

Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
2 1 1/4 3
/4 & 1 1/4 Conduit
3 2 3
/4 & 2 Compact Style Hub
4 2 1/2 3
/4 & 2 1/2 NEMA 4 & 12

NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
1
Standard 87/8 261/2 7 3
/4 24 4 1
/2 19/32 11 11
/32
Consult Factory 7 1 1 11
0-2 Compact 15 13 6 /8 11 10 /2 1 11 /32
3
Extra-Wide 157/8 261/2 7 3
/4 24 11 1/2 11 1
/2 1 11 11
/32
3 Standard 14 35 3/8 8 7
/8 33 9 1/2 9 1
/2 1 1/4 13 11
/32
3
3 Extra-Wide 22 35 3/8 8 7
/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7
/8 37 16 16 1 1/4 13 11
/32
7
5 Standard 22 49 9 /8 47 1/2 18 18 1 5/8 14 1/4 7
/16

NEMA 4 & 12 Enclosures


Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G H J K L M Diameter
7 9 3 13 1 1 1
Standard 8 /8 28 /16 7 /4 27 /16 4 /2 /2 11 3 5
/32 1 /2 1
3 — — 11
/32
4 0-2 Compact Consult
17 Factory
14 15/16 6 7
/8 9 16 16 2 11 3 5
/32 — 3 2 1/2 5 1/2 11
/32
9 3
Extra-Wide 15 7/8 28 9/16 7 3
/4 27 13/16 11 1/2 11 1/2 1
/2 11 3 5
/32 1 1/2 3 — — 11
/32
2
3 Standard 14 37 1/2 8 7
/8 36 3/4 9 1/2 9 1/2 3
/8 13 2 3
/4 1 1/2 4 — — 11
/32
3
3 Extra-Wide 22 37 1/2 8 7
/8 36 3/4 16 16 3
/8 13 2 3
/4 1 1/2 4 — — 11
/32
4 Standard 22 41 1/2 8 7
/8 40 3/4 16 16 3
/8 13 2 3
/4 1 1/2 4 — — 11
/32
5 Contact factory

Notes: Consult Factory


1. Indicates mounting hole is on the center line of the enclosure.
2. Hub included on NEMA Type 4 enclosure only.
3. Use Extra Wide Dimension for Duplex and Irrigation Pump Panels.

B47
TM - NEMA Control Dimensions
Combination Reversing Starters

NEMA 1 NEMA 4 NEMA 12

NEMA 4 Hub
Application Table

Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
1 3
2 1 /4 /4 & 1 1/4
3
3 2 /4 & 2
4 2 1/2 3
/4 & 2 1/2

NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 26 1/2 7 3/4 24 11 1/2 11 1/2 1 11 11
/32
3 Standard 22 35 3/8 8 7/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7/8 37 16 16 1 1/4 13 11
/32
5 Contact factory

NEMA 4 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G H J K L M Diameter
7 9 3 13 1 1 3
0-2 Standard 15 /8 28 /16 7 /4 27 /16 11 /2 11 /2 /8 11 5
3 /32 1 /21
3 — — 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
5 Contact factory

NEMA 12 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 3
/8 3
/8 11 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 11
/32
5 Contact factory

B48
Dimensions NEMA Control - TM
Combination 2 Speed

NEMA 1 NEMA 4 NEMA 12

NEMA 4 Hub
Application Table

Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
2 1 1/4 3
/4 & 1 1/4
3
3 2 /4 & 2
4 2 1/2 3
/4 & 2 1/2

NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 26 1/2 7 3/4 24 11 1/2 11 1/2 1 11 11
/32
3 Standard 22 35 3/8 8 7/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7/8 37 16 16 1 1/4 13 11
/32
5 Contact factory

NEMA 4 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G H J K L M Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 11 1/2 3
/8 11 5
3 /32 1 /21
3 — — 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 7
/8 13 2 3/4 1 1/2 4 — — 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
5 Contact factory

NEMA 12 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 3
/8 3
/8 11 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 11
/32
5 Contact factory

B49
TM - NEMA Controls Engineering Data
Ratings - Controllers - Type TM
Continuous ampere and maximum horsepower ratings are
in accordance with the following NEMA Standards:
Starters ICS 2-32 1B, ICS 2-321F
Contactors ICS 2-211.23, ICS 2-211.24

B Power Wiring Accommodation - Type TM1

Provision For Ring


Wire Range Pressure Tongue Lugs 3
NEMA Load Wire Terminal Terminal Screw
Size 2 Line Contactor Overload Type Type Width, In. Size
00 #14-#6 #14-#6 #14-#4 Copper (Cu) Saddle .625 #10-32
0 #14-#6 #14-#6 #14-#4 Copper (Cu) Saddle .625 #10-32
1 #14-#6 #14-#6 #14-#4 Copper (Cu) Saddle .625 #10-32
2 #14-#4 #14-#4 #14-#4 Copper (Cu) Box .62 #10-32
5
3 #8-#2/0 #8-#2/0 #8-#2/0 Copper (Cu) Box 1.04 /16-18
3
4 #6-250MCM #6-250MCM #6-250MCM Copper (Cu) Box 1.04 /4-18
3
5 #4-500MCM #4-500MCM #4-500MCM Aluminum Box 1.25 /8-Hole
3
6 (2)#4-500MCM (2)#4-500MCM (2)#4-500MCM or Copper (Cu) 1.25 /8-Hole

1
For aluminum (Al) load wiring accommodations on Size 00-4, refer to local sales office.
2
Devices are equipped with one (1) lug p[er phase, except size 6.
3
UL specifies only one (1) wire per lug.
Control Circuit Contact & Coil Terminals - Type TM

NEMA Terminal Copper Wire Size 4,5 Screw


Size Type Min. - Max. Size
00-6 Pressure #18-#12AWG #8-32
Saddle
4 One or two stranded copper wires of same size, or differing by (2)
gauge sizes.
5 Coil terminal wire on TM 00-2 is #14 AWG maximum.

Control Circuit Contact Rating - Type TM


10 Ampere Continuous Rating - Maximum 600 Volts, AC or DC

NEMA Amperes A-C Inductive (0.35pf) D-C Inductive


Size Contacts Volts, AC Continuous M a k e Break Volts, DC Make or Break
00-4 KTM-10
KTM-11 125V 1.1
120V or less 10 30A 3A 250V .55A
00-2 KTM-20 120-600V 3600VA 360VA (300V OR LESS) (138VA)
3-4 KTM-19 600V .2A
5-6 KTM35-10 10 60A 6A (301-600V) (120VA)
KTM35-11 7200VA 720VA

Overload Relay Contact Ratings - Type TM 4


9
2
NEMA Continuous A-C Inductive (0.35pf)
Size Contact Volts, AC Am per es Make Break
N.C. 120V or less 15A 1.5A
00-6 120-600V 2.5 1800VA 180VA
N.O 120V or less 3A .3A
120-600V 360VA 36VA

B50
Dimensions NEMA Controls - TM
Control Transformer Sizes
Coil Burden - Type TM For Type TM A-C Contactors Or Starters

Contactor or Transformer Sizes-


60Hz. 50Hz. 25Hz.
Starter Volt-Amperes, 60 Hertz
NEMA Volt - Amperes Volt - Amperes Volt - Amperes
NEMA No. of Standard 100W Extra
Size Poles Inrush Sealed Inrush Sealed Inrush Sealed
Size Poles Capacity Capacity
00-2 2-4 210 18 210 20 135 19
00.0.
3 2-4 724 30 724 32 -- -- 2-4 50 150
4
5
2-4
2-3
880
1790
39
295
880
--
42
--
--
--
--
--
1& 2
3&4 2-4 250 500
B
61 2-3 3160 435 3300 490 -- -- 5 2-3 350 500
62 2-3 50 150
1 Size 6 has two operating coils connected in series. Values given for 2 For starter with control relay; starter coil is full voltage.
two coils so connected.

Ratings Of Low-Voltage Contactors


For Transformer Primaries 3

Transformer Rating 4 -KVA, 50/60 Hz. 8-Hour Rating


Single Phase Three Phase of Contactor
Contactor 460 or Amperes
Size 115V 230V 575V 230V 575V Open Enclosed
0 0.9 1.4 1.9 1.7 2.5 20 18
1 1.4 1.9 3 4.1 5.3 30 27
2 1.9 4.6 5.7 7.6 12 50 45
3 4.6 8.6 14 15 23 100 90
4 5.7 11 22 23 46 150 135
5 14 28 40 46 91 300 270
6 28 57 86 91 180 600 540

3 This table does not apply to transformers in resistance welding service.


4 This table applies to contactors used with transformers having an inrush of not more than
(20) times their full-load current, irrespective of the nature of the secondary load.

Kilowatt Ratings Of Low-Voltage Transformers


For Resistive-Heating Loads Other Than Infrared-Lamp Loads 5
Per NEMA ICS 2.210-1

1 O, 2-Pole Contactors 3 O, 3-Pole Contactors 8-Hour Rating


(Open or Closed) (Open or Closed) of Contactor
Contactor Heating Load, KW Heating Load, KW Amperes
Size 115V 230V 460V 575V 230V 460V 575V Open Enclosed
1 3 6 12 15 10 20 25 30 27
2 5 10 20 25 17 34 43 50 45
3 10 20 40 50 34 68 86 100 90
4 15 30 60 75 52 105 130 150 135
5 30 60 120 150 105 210 260 300 270
6 60 120 240 300 210 415 515 600 540
7 90 180 360 450 315 625 775 900 810

5 This Table applies to contactors used to switch the load at the utilization voltage of the heat-
producing elements with a duty which requires continous operation of not more than five (5)
openings per minute.

B51
TM - NEMA Controls Engineering Data
For Starters 6013-TM;
Contactors 7707-TM Non-Combination

Wiring Diagram Front View

Connection For Pilot Devices


Cover Mounted Pilot Devices 3 Wire Control Remote Pilot Devices Transformer Connections

Volts Connections L1 L2 Fig.


240 H1 & H3,H2 & H4 H1 H4 2
480 H2 & H3 H1 H4 2
Connect To Coil Terminals All --
Others

Start-Stop Pushbutton Pilot Light


Automatic Reset
Momentary Contact Pushbutton Automatic reset operation should not
be used with two wire control.

Separate Control
Remove wire "A" when it is supplied.
Connect separate control lines to the
"1" terminal on the pilot device and
the "4" terminal on the starter.
Coil Terminal wire to be #14 AWG
maximum.

B52
Engineering Data NEMA Controls - TM
For Starters 6030-TM;
Contactors 6031-TM

Elementary Diagram Seperate Control

Remove wire "A" when it is supplied


Connect seperate control lines to the
"1" terminal on the pilot device and
the "8" terminal on the starter. Coil
terminal wire to be No. 14 AWG
maximum.
B
Pushbutton Control

Wiring Diagram Front View

When Limit Switches Are


Used
Omit Wires "C" and "D" and
Connect Per Dotted Lines
Contactors "F" & "R" Are
Mechanically Interlocked

B53
TM - NEMA Controls Engineering Data
For Starters 6050-TM

Elementary Diagram Separate Control

Remove wire "A" when it is supplied


Connect separate control lines to the
"1" terminal on the pilot device and
Three Phase the "8" terminal on the starter. Coil
B Two Speed
Two Winding
terminal wire to be No. 14 AWG
maximum.
Motor
Separate
Winding
Pushbutton Control

Wiring Diagram Front View

Contactors "HI" and "LO" Are


Mechanically Interlocked

B54
Engineering Data NEMA Controls - TM
For Starters 6050-TM
Wiring Diagram Front View
Elementary Diagram

Momentary Contact Pushbuttons


Figure 1 Figure 2

Connections Of Motor And Pushbotton


Terminals To Starter Terminals

Motor Pushbotton A B C D E F M1 M2
Figure 1 Figure 2 T6 T4 T5 T1 T2 T3 Low High
Figure 2 Figure 1 T1 T2 T3 T6 T4 T5 High Low
Figure 3 Figure 1 T1 T2 T3 T6 T4 T5 High Low

Three Phase Two Speed One Winding


Motor Connection Data
Figure 1 Constant Horsepower Figure 2 Constant Torque Figure 3 Variable Torque

L1 L2 L3 Open Together Speed L1 L2 L3 Open Together Speed L1 L2 L3 Open Together Speed


T1 T2 T3 T4,T5,T6 Low T1 T2 T3 T4,T5,T6 Low T1 T2 T3 T4,T5,T6 Low
T6 T4 T5 T1,T2,T3 High T6 T4 T5 T1,T2,T3 High T6 T4 T5 T1,T2,T3 High

B55
TM - NEMA Controls Engineering Data
For Starters 6018-TM, 6020-TM Combination

Dual voltage transformer is shipped as


shown connected for higher voltage.
Reconnect jumpers "J" per table for
lower voltage.

Voltage Connect L1 L2
B 230
H1 to H3
H2 to H4
H1 H4

460 H2 to H3 H1 H4
All Single H1 H2
Primary Transformers

B56
Engineering Data NEMA Controls - TM

For Starters 6038-TM, 6040-TM Combination

Automatic reset operation


should not be used with
two wire control

When limit switches are used


omit wire "C" and "D" and
connect per dotted lines

Connections For Flange Mounted Or Remote Pilot Devices

Dual voltage transformer is shipped as


shown connected for higher voltage.
Reconnect jumpers "J" per table for
lower voltage.

Voltage Connect L1 L2
H1 to H3 H1 H4
230
H2 to H4
460 H2 to H3 H1 H4
All Single H1 H2
Primary Transformers

B57
TM - NEMA Controls Engineering Data
Standard A-C Wiring Diagrams
Two-Speed, Two Winding (Separate Winding)

For Starters 6058-TM, 6060-TM Combination

Elementary Diagram: Wiring Diagram - Front View

B
Two Speed
Two Winding
Motor

Contactors
"HI" and "LO" are
Mechanically
Interlocked

Common Control Separate Control

When control circuit obtains power Remove wire "A" when it is supplied.
from the line side of the starter as Connect separate control lines as
shown, and control conductors follows:
extend beyond the enclosure, they With internally mounted fuses,
must have overcurrent protection connect to fuse block.
rated not in excess of 500% of the Without internal fuses, an external
control circuit conductor ampacity. fuse must be mounted immediately
Such protection should be installed in adjacent to the controller. Connect to
the field if starter does not have "1" terminal on pilot devices and "6"
control fuses. terminal on starter.

B58
Engineering Data NEMA Controls - TM
Wiring Diagrams
Two-Speed, One Winding (Consequent Pole)
Wiring Diagram - Front View
For Starters 6058-TM, 6060-TM Combination

Elementary Diagram

Two Speed
One Winding
Motor
B

Contactors "M1" and "M2"


are Connections Of Motor And Pushbutton Terminals
Mechanically interlocked
Motor Pushbutton A B C D E F M1 M2
Figure 1 Figure 2 T6 T4 T5 T1 T2 T3 Low Hi
Figure 2 Figure 1 T1 T2 T3 T6 T5 Hi Low
Three Phase Two Speed One Winding Figure 3 Figure 1 T1 T2 T3 T6 T4 T5 Hi Low
Motor Connection Data

Figure 1 Constant Horsepower Figure 2 Constant Torque Figure 3 Variable Torque

L1 L2 L3 Open Together Speed L1 L2 L3 Open Together Speed L1 L2 L3 Open Together Speed


T1 T2 T3 T4,T5,T6 Low T1 T2 T3 T4,T5,76 Low T1 T2 T3 T4,T5,76 Low
T6 T4 T5 T1,T2,T3 High T6 T4 T5 T1,T2,T3 High T6 T4 T5 T1,T2,T3 High

Connections For Case Mounted Transformer (When Provided) Wiring Diagram (Remove Wire "A")
Or Remote Pilot Devices
Momentary Contact Pushbuttons

Accessory And Replacement Kits


KTM and KTR accessories can;
be used with this controller.
Other replacement coil by Part No. on
coils.
For other renewal parts information,
refer to S.B. 6000 TM.
Voltage Connect L1 L2 Auxiliary contacts "W"
H1 to H3 H1 H4 rated for standard duty
230 600 volts maximum.
H2 to H4
Dual voltage transformer is shipped as 460 H2 to H3 H1 H4 Contact Cat. No.
shown connected for higher voltage. All Single 1 N.O. KTM-10
H1 H2
Reconnect jumpers "J" per table for Primary Transformers 1 N.C. KTM-11
lower voltage.

B59
TM - NEMA Control Numbering System
Contactors & Non Combination Starters

Type of Starter or Contactor


T - Standard unit with standard TM size 00 -4 starter or contactor. Cover Control
V - Standard unit with standard Vacuum starter or contactor.
U - Standard unit with standard TM size 5 starter or contactor. A - Reset button in cover for
A - Standard unit except with ambient compensated overload relays. overloads.

B K - Irrigation Pump Controller. B- Reset button and Hand-Off-


Auto selector switch.
C- Reset button and Start-Stop
push button
O- None (no reset button or
controls in cover)

Product Code
13 - Starters
30 - Rev. Starter Enclosure Type
31 - Rev. Contactors
A - NEMA 1
77 - Contactors
W - NEMA 4
90 - Part Winding Starters
R - NEMA 3R
T - NEMA 12
U - Open Type

T 13 A A 3 1 - 46

Number of Poles
1 - One Pole
2 - Two Pole
3 - Three Pole
4 - Four Pole

NEMA Size or Amp. Rating OR


A - Size 00
O - Size 0 Suffix With Transformer Suffix W/O Transformer
1 - Size 1, 1PW (secondary 110-120V with single fuse) Coil Volts & Hertz Suffix
P - Size 1 1/2 Suffix 110-120/60 or 110/50 - 76
2 - Size 2, 2PW Transformer Primary 100 Watt 220-240/60 or 220/50 - 26
3 - Size 3, 3PW Volts & Hertz Standard Extra 440-480/60 or 440/50 - 46
4 - Size 4, 4PW Capacity Capacity 550-600/60 or 550/50 - 56
5 - Size 5, 5PW 220-240/60 or 220/50 - T26 208/60 - 86
- C26
6 - Size 6, 6PW 440-480/60 or 440/50 - T46 - C46
550-600/60 or 550/50 - T56 - C56
208/60 - T86 - C86
380/50 - T35 - C35
220/25 - T22 - C22
440/25 - T42 - C42

B60
Numbering System NEMA Control - TM
Combination Starters

Type of Starter or Contactor Suffix With Transformer Suffix W/O Transformer


T- Std. unit with standard Type TM starter or contactor. (secondary 110-120V with single fuse) Coil Volts & Hertz Suffix
V- Std. unit with std.Type Vacuum starter or contactor. Suffix 110-120/60 or 110/50 - 76
U- Std. unit with std. TM size 5 starter or contactor. Transformer Primary 100 Watt 220-240/60 or 220/50 - 26
A- Standard unit except with ambient compensated Volts & Hertz Standard Extra 440-480/60 or 440/50 - 46
overload relays. Capacity Capacity 550-600/60 or 550/50 - 56
C-
E-
Compact
Extra-Wide
220-240/60 or 220/50 - T26
440-480/60 or 440/50 - T46
- C26
- C46
208/60 - 86 B
D- Duplex Pump Controller. (Include Dual Dis. Switch) 550-600/60 or 550/50 - T56 - C56
SD- Duplex Pump Controller. (Include Single Dis. Switch) 208/60 - T86 - C86
K- Irrigation Pump Controller. 380/50 - T35 - C35
220/25 - T22 - C22
440/25 - T42 - C42
Product Code
18 -Fused Starter OR
20 -C/B Starter
38 -FusedRev. Starter Number of Poles
40 -C/B Rev. Starter 3 - Three Pole

T 18 T A 3 1 6 03 - T46

Disconnect
Enclosure Type Rating
Size of Starter
A - NEMA 1 2 - 240 Volts
W - NEMA 4 0 - Size 0
1 - Size 1 4 - 480 Volts
R - NEMA 3R 6 - 600 Volts
T - NEMA 12 2 - Size 2
3 - Size 3
4 - Size 4
5 - Size 5 Fuse Clip Size or Circuit Trip Rating or Range
6 - Size 6 Fuse Clip Size Motor Circuit Protector
(Applicable only to Bull. 6018-38 & 6318) (Used as standard at 440-600V)
03 - 30 amp 04 - 400 amp Adjustable Trip 600V AC Max.
06 - 60 amp 07 - 600 amp 71 - 3 amp 77 - 150 amp
Cover Control 01 - 100 amp 08 - 800 amp 72 - 7 amp 78 - 225 amp
A - Reset button in cover for 02 - 200 amp 10 - non-fused 73 - 15 amp 79 - 400 amp
overloads Class J Fuse Clip Size 74 - 30 amp 80 - 600 amp
B- Reset button and Hand-Off- 13 - 30 amp 12 - 200 amp 75 - 50 amp 81 - 800 amp
Auto selector switch 16 - 60 amp 14 - 400 amp 76 - 100 amp 82 - 1200 amp
C- Reset button and Start-Stop 11 - 100 amp 17 - 600 amp Thermal-Magnetic Trip Breaker
push button Class R Fuse Clip Size (Used as standard at 208-220V)
4 E- Hand-off Auto Selector Switch 93 - 30 amp 94 - 400 amp 00 - Non-Auto 10 - 200 amp
9
2 but no reset button 96 - 60 amp 97 - 600 amp 01 - 15 amp 11 -225 amp
F- Start-Stop push button but no 91 - 100 amp 98 - 800 amp 02 - 20 amp 12 - 250 amp
reset button 92 - 200 amp 03 - 40 amp 13 - 300 amp
O- None (no reset button or 04 - 50 amp 14 - 400 amp
Circuit Breaker Trip Rating or Range
controls in cover) 05 - 70 amp 15 - 500 amp
(Applicable only to Bull. 6020-40 & 6320)
06 - 100 amp 16 - 600 amp
07 - 125 amp 17 - 30 amp
08 - 150 amp 18 - 90 amp
09 - 175 amp 19 - 350 amp

B61
TM - NEMA Control Numbering System

2 Speed Starters

Cover Control
Type of Starter or Contactor A - Reset button in cover for overloads.
T - Standard unit with standard Type TM starter or contactor. B - Reset button and High-Off-Low selector switch.
Standard unit with vacuum starter or contactor. C - Reset button and Fast-Slow -Stop push button
V -
B U
A
-
-
Standard
Standard
unit
unit
with standard TM size 5 starter or contactor.
except with ambient compensated overload relays.
E
F
-
-
High-Off-Low selector switch but no reset button
Fast-Slow-Stop push button but no reset button
O - None (no reset button in cover)

Enclosure Type
A - NEMA 1 Size of Starter
S - NEMA 1 (Gasketed) 0 - Size 0 4 - Size 4
U - Open Type 1 - Size 1 5 - Size 5
W - NEMA 4 2 - Size 2 6 - Size 6
T - NEMA 12 3 - Size 3
Motor Windings
C - Consequent Pole
S - Separate Windings

T 60 A A 2 C 2 4 03 - 76
Product Code
50 - Non Combination 2 Speed
58 -Fused Combination 2 Speed
60 -C/B Combination 2 Speed
Number of Speed Disconnect
2 - Two Speed Rating
2 - 240 Volts
Motor Output 4 - 480 Volts
C - Constant Torque or HP 6 - 600 Volts
V - Variable Torque HP

Fuse Clip Size or Circuit Trip Rating or Range Suffix With Transformer
(secondary 110-120V with single fuse)
Fuse Clip Size Motor Circuit Protector Suffix
(Applicable only to Bull. 6058) (Used as standard at 440-600V) Transformer Primary 100 Watt
03 - 30 amp 04 - 400 amp Magnetic Adjustable Trip 600V AC Max. Volts & Hertz Standard Extra
06 - 60 amp 07 - 600 amp 71 - 3 amp 77 - 150 amp Capacity Capacity
01 - 100 amp 08 - 800 amp 72 - 7 amp 78 - 225 amp
220-240/60 or 220/50 - T26 - C26
02 - 200 amp 10 -non-fused 73 - 15 amp 79 - 400 amp
440-480/60 or 440/50 - T46 - C46
Class J Fuse Clip Size 12 - 200 amp 74 - 30 amp 80 - 600 amp
550-600/60 or 550/50 - T56 - C56
13 - 30 amp 14 - 400 amp 75 - 50 amp 81 - 800 amp
208/60 - T86 - C86
16 - 60 amp 17 - 600 amp 76 - 100 amp 82 - 1200 amp
380/50 - T35 - C35
11 - 100 amp Thermal-Magnetic Trip Breaker 220/25 - T22 - C22
Class R Fuse Clip Size 94 - 400 amp (Used as standard at 208-220V) 440/25 - T42 - C42
93 - 30 amp 97 - 600 amp 00 - Non-Automatic 10 - 200 amp
96 - 60 amp 98 - 800 amp 01 - 15 amp 11 -225 amp Suffix Without Transformer
91 - 100 amp 02 - 20 amp 12 - 250 amp
Coil Volts & Hertz Suffix 4
92 - 200 amp 03 - 40 amp 13 - 300 amp 110-120/60 or 110/50 - 76 9
14 - 400 amp 2
Circuit Breaker Trip Rating or Range 04 - 50amp 220-240/60 or 220/50 - 26
05 - 70 amp 15 - 500 amp 440-480/60 or 440/50 - 46
(Applicable only to Bull. 6060)
06 - 100 amp 16 - 600 amp 550-600/60 or 550/50 - 56
07 - 125 amp 17 - 30 amp 208/60 - 86
08 - 150 amp 18 - 90 amp
09 - 175 amp 19 - 350 amp

B62
Numbering System NEMA Control - TM
Reduced Voltage Auto Transformer Starters

Type of Starter or Contactor


T - Standard unit with standard Type TM starter or contactor. Cover Control
V - Standand unit with vacum starter or contactor. A - Reset button in cover for overloads.
U - Standard unit with standard TM size 5 starter or contactor. B - Reset button and Hand-Off-Auto selector switch.
A - Standard unit except with ambient compensated overload relays. C
O
-
-
Reset button and Start-Stop push button
None (no reset button in cover) B

Enclosure Type
Size of Starter
A - NEMA 1
U - 0 - Size 0 4 - Size 4
Open Type
W - 1 - Size 1 5 - Size 5
NEMA 4
T - 2 - Size 2 6 - Size 6
NEMA 12
3 - Size 3

T 82 A A 4 M E - 46

Product Code
82- Non Combination
83- Fused Combination
84- C.B. Combination

Line Voltage
A - 208V/60Hz E - 460V/60Hz
B - 230V/60Hz F - 440V/50Hz
C - 220V/50Hz G - 575V/60Hz
D - 380V/50Hz

Motor Horsepower
A - 5 HP M - 100 HP
B - 7 1/2 HP N - 125 HP
C - 10 HP P - 150 HP Suffix With Transformer Suffix Without Transformer
D - 15 HP Q - 200 HP (secondary 110-120V with single fuse) Coil Volts & Hertz Suffix
E- 20 HP R - 250 HP Suffix 110-120/60 or 110/ - 76
F- 25 HP S - 300 HP Transformer Primary 100 Watt 50 - 26
G - 30 HP T - 400 HP Volts & Hertz Standard Extra 220-240/60 or 220/ - 46
H - 40 HP U - 450 HP Capacity Capacity 50 - 56
J - 50 HP V - 500 HP 220-240/60 or 220/50 - T26 - C26 440-480/60 or 440/ - 86
K - 60 HP W - 600 HP 440-480/60 or 440/50 - T46 - C46 50
L - 75 HP X- Other 550-600/60 or 550/50 - T56 - C56 550-600/60 or 550/
208/60 - T86 - C86 50
380/50 - T35 - C35 208/60
220/25 - T22 - C22
440/25 - T42 - C42

B63
General Information 5000 - AC Control

Application
The 5000 Space Savers in NEMA Sizes 00 thru 5 offer versatile and compact AC contactors for industrial motor, heating and other
power circuit switching. Simplified design coupled with built-in reliability assures the user long, trouble-free operation in ma-
chine tools, process controls, air-conditioning, custom panels and other demanding applications.
B Description
All 5000 magnetically operated contactors incorporate a modern, modular design compatible with other control component
modules. Terminal location make them ideal for straight-through wiring and for wire-channel layouts. Accessible, up-front
pressure-type terminals are standard.
The hot molded, high arc resistant two or three piece housings not only totally enclose contacts and operating coils for environ-
mental protection; but also separate them as added protection against internal phase-to-phase short circuits.
Generous size, long wearing double break contacts are furnished on all sizes. Contacts are made of silver cadmium oxide for
"anti-weld" protection under high inrushes. Contacts do not require adjustment or periodic dressing (filing).
Coil Data
Standard coils for continuous duty service are equipped with pressure type terminals. Molded coil constrution resists moisture;
thermal and mechanical stress.

Typical User Benefits:


Modern Modular Design - makes contactors compatible with Fast Installation - Accessible up-front pressure type
other control panel components. Ideal for wire-channel layouts. terminals on both power and control circuits, take unlugged
Compact Size - 5000 Contactors conserve control panel area stripped wire. Design permits straight-through wiring.
without sacrificing accessibility or reliability. The 100 amp. Size 3 Quick, Easy Inspection - Simply withdraw the front
contactors occupy less than 19.0 sq. in. of panel space. housing piece, after removing two screws, all main con-
Only 15 Basic Parts - This simple design affords longer operating tacts are in full view. No need to disturb wiring or remove
life and greater reliability than more complex units. contactor from panel for complete inspection of all parts.

3. Three piece
molded housing.
8. Stainless
steel springs.
4. Arc b a r r i e r s . 1. Double Break silver
cadmium oxide contacts.

5. Side mounted
auxiliaries.

6. Free-floating arma-
ture-magnet frame.

7. Molded continuous
duty coil.

2. Pressure
3. Three piece type terminals.
molded housing.

B64
AC Control - 5000 Non-Reversing Contactors

3 Pole Contactors -Three Phase Auxiliary Contact Rating B


8-Hour Rating Open Type Sizes 00 - 5
NEMA in Amperes AC Amperes
Size Open E nclose d Catalog No. Price Volts Continuous Inrush
120 6 60
00 10 9 5009A3001- * $ 276.
280 3 30
0 20 18 5000A3001- * 348.
480 1.5 15
1 30 27 5001A3001- * 408.
600 1.2 12
2 50 45 5002A3001- * 744.
3 100 90 5003A3001- * 1200.
4 150 135 5004-3001- * 2880. Auxiliary Contacts (Interlocks)
5 300 270 5005-3001- * 6276. Max. No. of
NEMA N.O. or N.C. or N.O. - N.C.
Contactor comes standard with 1N.O. auxilary.
Size Auxiliary units
00, 0 & 1 2
2, 3, 4, 5 4

1
Ratings - Ampere and Horsepower, Single Speed Motors
Amperes Three Phase - Horsepower Rating Single Phase - Horsepower Rating
Plug-Stop or Plug-Stop or
NEMA Starting Jogging Duty Starting Jogging Duty
Size Open Enclosed 115V 230V 480/575V 115V 230V 480/575V 115V 230V 115V 230V
3 1
00 10 9 /4 1 1
/2 2 ---- ---- ---- /3 1 1/2 ---- ----
1
0 20 18 2 3 5 1 1 1
/2 2 1 2 /2 1
1
1 30 27 3 7 /2 10 2 3 5 2 3 1 2
2 50 45 7 15 25 ---- 10 15 3 7 2 5
3 100 90 ---- 30 50 ---- 20 30 ---- ---- ---- ----
4 150 135 ---- 50 100 ---- 30 60 ---- ---- ---- ----
5 300 270 ---- 100 200 ---- 75 150 ---- ---- ---- ----

Notes:
1. These ratings are based on locked rotor current not exceeding six
times motor full load current for the max. horsepower rating.

Ordering Information Coil Table


Use complete catalog number. NEMA Size DC Voltage Suffix NEMA Size 60Hz/Voltage Suffix
Replace the (*) with the suffix from 00-5 incl. 24 82 00-5 incl. 120 11
the coil table. 00-5 incl. 48 32 3,4,5 208/240 21
Modification Page 00-5 incl. 120 12 00, 0, 1, 2 208 90
00-5 incl. 240 22 00, 0, 1, 2 240 21
** For all DC Coils up to NEMA Size 3 add $192 00-5 incl. 480 41
Size 4 & 5 add $480 00-5 incl. 600 51

Discount Schedule JC 25 B65


Modifications & Accessories AC Control - 5000
Accessory Kits & Special Features 5
Contact Kits - 1 Pole
For Field Installation Discount Sch. JC 20
Basic NEMA Discount Sch. JC 80
Auxiliary Interlocks
For NEMA Sizes 00-5 Contactors Kit No. Price Cat. No. Size Kit No. Price
5009- 00 5M59 $ 62.
N.O. Std. 5M63 $ 50.
5009A or B 00 5M87 62.
N.C. Std. 5M64 50.
5000A or B 0 5M87 62.
N.O. & N.C. Std. 5M65 88.
5000- 0 5M50 83.
N.O. Low Power 5M63L 176.
5001A or B 1 5M19 83.
B N.C. Low Power
N.O. & N.C. Low Power
5M64L
5M65L
176.
302.
5001-
5002A or B
1
2
5M51
5999-2521
104.
131.
N.O. Std. & N.C. Low Power 5M66 227.
5002- 2 5M52 173.
N.O. Low Power & N.C. Std. 5M65L0 227.
5003A or B 3 5M80 207.
N.C. Std. Early Close 5M64E 50.
5003- 3 5M53 207.
N.O. Low Power & N.C. Std.
5004- 4 5M54 386.
Late Break 5M68E 2 88.
5005- 5 5999-0045 803.
N.C. Low Power - Late Break 5M64LE 176.
N.O. Std. & N.C. Low Power
Late Break 5M67 2 227.
2
N.O. Low Power & N.C. Low Power 5M69 302.
Tandem Mounting Kit 1 5M60DA 32.

Reversing & Starter or Discount Sch. JC 20


Multi-Speed Contactor
Accessory Kit Size Kit No. Price
3
00, 0 & 1 5M115 $ 76.
4
Mechanical
0&1 5M110 76. AC Coil Data and Coil Kits
2, 3, & 4 5999-4737 76.
Interlock 3 B a s i c NEMA V o l t s V.A. 60Hz
2 5999-4717 76. Discount Sch.JC 80
5 5999-4757 315. Cat. No. Size 60Hz Inrush Sealed Kit No. Price
5 to 4 5999-4748 315.
5009A 00 120 120 28 5ML25 53.
Reversing 0&1 23081.692-1 50. 5000A 0 208 5ML26 53.
Contactor 2 & 3A 23082.79 69. 5001A 1 240 5ML29 53.
Base Plate: 4 23083.30 88. 480 5ML27 53.
Series 5000 5 23085.312-1 189. 600 5ML28 53.

Notes: 5002A 2 120 290 48 5999-1801 76.


1. Contains mounting hardware only. Order auxiliary separately. 208 5999-1805 76.
Not for 7000 or 7001 Series Contactors. 240 5999-1802 76.
2. Not for use on 5000 contactor size 00, 0, 1 & 2 or 5DP contactors 10/
480 5999-1803 76.
40, 40 & 75 amp. sizes.
600 5999-1804 76.
3. For use with style A contactors only. Style A contactors are
5002 2 120 264 41 5ML21 110.
identified by the letter A following the fourth digit in the catalog
5003A 3 240 5ML22 110.
number.
4. Not for use on style A contactors. 480 5ML23 110.
5. Kit contains: stationary contacts, movable contacts & contact 600 5ML24 110.
springs. 5003 3 120 672 72 5ML41 156.
5004 4 240 5ML42 156.
480 5ML43 156.
600 5ML44 156
5005 5 120 1776 144 5ML51 276.
240 5ML52 322.
480 5ML53 322.
600 5ML54 322..

B66
AC Control - 5000 Engineering Data

B67
Contactors & Starters Index NEMA Control

Description Page Number


General Information - HP ...................................... C2
AC Magnetic Contactors - HP .............................. C4
AC Magnetic Reversing Contactors - HP.............. C4
AC Magnetic Starters - HP ................................... C5
AC Magnetic Reversing Starters - HP .................. C5
AC Magnetic Combination Starters - HP .............. C6 C
Modifications and Parts ....................................... C7
Modification and Spare Parts ............................... C8
Numbering System ............................................... C9
Engineering Data ................................................ C10
For HP Overload Heaters see SectionB Index

C1
HP - NEMA Control General Information
The Joslyn Clark NEMA Size Starter
That Saves You Money

NEMA Type 1 Enclosed NEMA Type 1 Enclosed


Non - Reversing Starter Reversing Starter

3
8
0

NEMA Type 1 Enclosed


Duplex Pump Controller
Combination Starters

C2
General Information NEMA Control - HP

Quality with economy of cost and space


The Joslyn Clark HP Motor Starter has been devel- This compact starter takes less than 19 sq. in. of
oped through many generations of controllers. panel space, permitting the use of smaller, less
Closely related to the TM design, the HP starter is costly enclosures. It provides more wiring space for
rated for its horsepower capability as well as in easy wiring and requires only two mounting screws
standard NEMA frame sizes. Like the TM starter, to save installation time and cost
our HP starter was designed in one piece as a
starter, a single integrated unit consisting of a
power contactor and a thermal overload relay
NEMA sizes 00, 0, 1 & 2 are the same small physical
size, providing greater flexibility.
C
mounted on a rigid common base.

NEMA Sizes 00, 0, 1, & 2


Quality with economy of cost and space
LOW ENERGY 8.4 VA COIL COVER NAME PLATE

Same energy efficient coil for NEMA Clear and easy to identify size,
sizes 00, 0, 1 & 2. Reduces trans- rating, and catalog number.
former size and cost. Small trans-
former size saves panel space. Low
VA inrush coil reduces line disturbance, AUXILIARY CONTACTS
ideal for use with solid state control.
Easy to install

Clear side cover

One Kit may be attached to


each side of the starter pro-
viding up to four contacts

TRUE "UP-FRONT" Contacts positive driven


"STRAIGHT THROUGH" from main contact carrier
WIRING DESIGN

Makes the HP Starter easy to wire and Contact Kits -


One N.O. KHP - M10
safe to trace. Save through reduced
Two N.O. KHP - M20
wiring time and panel cost.
N.O. & N.C. KHP - M11

4
8
5

SMALL SIZE "UNIQUE" SPRING


LOAD TERMINALS
Requires only 19 sq. in. of panel
space. For fast load connection. Save by
reducing starter wiring time.

C3
HP - NEMA Control AC Contactors

HPC02OU2 HPC10AA3 HPRC25AO3

Non-Reversing Contactors - Type HPC


2-Pole, Single Phase
Maximum Motor Contin- NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower Rating General Purpose Watertight Industrial - Dust-tight
uous Tungs
NEMA Ampere Lamp
Contin-
1 1 1 1
Size 115V 220V Rating Load Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
00 1
/3 1 ---- 9 5 HPC02A02 * $204. HPC02W02 * $ 556. HPC02T02 * $ 334. HPC02U02 * $ 180.
0 1 2 ---- 18 10 HPC05A02 * 256. HPC05W02 * 606. HPC05T02 * 384. HPC05U02 * 232.
1 2 3 ---- 27 15 HPC10A02 * 306. HPC10W02 * 664. HPC10T02 * 432. HPC10U02 * 282.
2 3 7 1/2 ---- 45 30 HPC25A02 * 660. HPC25W02 * 1260. HPC25T02 * 810. HPC25U02 * 510.
3-Pole, Three Phase
460-
200V 230V 575V
00 1 1/2 1 1/2 2 9 5 HPC02A03 * 234. HPC02W03 * 586. HPC02T03 * 364. HPC02U03 * 210.
0 3 3 5 18 10 HPC05A03 * 286. HPC05W03 * 636. HPC05T03 * 414. HPC05U03 * 262.
1 7 1/2 7 1/2 10 27 15 HPC10A03 * 336. HPC10W03 * 690. HPC10T03 * 462. HPC10U03 * 312.
2 10 15 25 45 30 HPC25A03 * 660. HPC25W03 * 1296. HPC25T03 * 846. HPC25U03 * 540.

Reversing Contactors - Type HPRC


3-Pole, Three Phase
Maximum Motor NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower Rating Continuous General Purpose Watertight Industrial - Dust-tight
NEMA 460/ Ampere 2
2 2 2
Size 200V 230V 575V Rating Catalog No. Price Catalog No Price Catalog No. Price Catalog No. Price
00 1 1/2 1 1/2 2 9 HPRC02A03 * 588. HPRC02W03 * 1062. HPRC02T03 * 800. HPRC02U03 * 540.
0 3 3 5 18 HPRC05A03 * 696. HPRC05W03 * 1170. HPRC05T03 * 906. HPRC05U03 * 648.
1 7 1/2 7 1/2 10 27 HPRC10A03 * 870. HPRC10W03 * 1458. HPRC10T03 * 1018. HPRC10U03 * 800.
2 10 15 25 45 HPRC25A03 * 1572. HPRC25W03 * 2484. HPRC25T03 * 1818. HPRC25U03 * 1380.

Note:
1. Price includes contactor complete with one N.O. 2. Price includes contactor complete with N.O. interlock on each 4
contol-circuit contact. contactor. All contactors are mechanically and electrically interlocked. 1
2

Ordering Information Coil Table


Use complete catalog number. Replace Engineering Data pages C10-13 60Hz Voltage Suffix 60Hz Voltage Suffix
the (*) with the suffix from coil table. Modification pages C7-8 24 Separate Control -96 200-240 -26
120 Separate -76 277 -66
Control 440-480 -46
550-600 -56

C4 Discount Schedule JC12


AC Starters NEMA Control - HP

C
HP02AA3
HP10UO3 HPR10UO3

Non-Reversing Starter Type HP


2-Pole, Single Phase (Requires 1 Overload Heater)
Maximum Motor NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Contin-
Horsepower General Purpose Watertight Industrial - Dust-tight
uous
Rating 460/
NEMA Ampere
1 1 1
Size 115V 220V 575V Rating Catalog No. Price Catalog No. Catalog No. Price1 Catalog No. Price
00 1
/3 1 ---- 9 HP02AA2 * HP02WA2 *
$ 286. Price $ 618. HP02TA2 * $ 396. HP02U02 * $ 262.
0 1 2 ---- 18 HP05AA2 * 318. HP05WA2 * 650. HP05TA2 * 426. HP05U02 * 294.
1 2 3 ---- 27 HP10AA2 * 366. HP10WA2 * 708. HP10TA2 * 474. HP10U02 * 342.
3-Pole, Three Phase (Requires 3 Overload Heaters)
460/
200V 230V 575V
00 1 1/2 1 1/2 2 9 HP02AA3 * 286. HP02WA3 * 618. HP02TA3 * 396. HP02U03 * 262.
0 3 3 5 18 HP05AA3 * 352. HP05WA3 * 684. HP05TA3 * 462. HP05U03 * 328.
1 7 1/2 7 1/2 10 27 HP10AA3 * 400. HP10WA3 * 742. HP10TA3 * 510. HP10U03 * 376.
2 10 15 25 45 HP25AA3 * 762. HP25WA3 * 1380. HP25TA3 * 928. HP25U03 * 642.

Reversing Starters - Type HPR


3-Pole, Three Phase (Requires 3 Overload Heaters)
Maximum Motor Contin- NEMA Type 1 NEMA Type 4 NEMA Type 12 Open Type
Horsepower uous General Purpose Watertight Industrial - Dust-tight
NEMA Rating 460/ Ampere
2 2 2 2
Size 200V 230V 575V Rating Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
00 1 1/2 1 1/2 2 9 HPR02AA3 * $ 672. HPR02WA3 * $ 1104. HPR02TA3 * $ 838. HPR02U03 * $ 624.
0 3 3 5 18 HPR05AA3 * 786. HPR05WA3 * 1218. HPR05TA3 * 952. HPR05U03 * 738.
1 7 1/2 7 1/2 10 27 HPR10AA3 * 906. HPR10WA3 * 1506 HPR10TA3 * 1066. HPR10U03 * 834.
2 10 15 25 45 HPR25AA3 * 1674. HPR25WA3 * 2566. HPR25TA3 * 1900. HPR25U03 * 1482.

Note: 2. Price includes starter complete with N.O. interlock on each contactor and overload
0 relay less heaters. All starters are mechanically and electrically interlocked.
2
1. Price includes starter complete with N.O. interlock
3 and overload relay less heaters. 3. NEMA 3R add 60.00 to NEMA 12 List

Ordering Information Coil Table


Use complete catalog number. Replace Engineering Data page C10-13 60Hz Voltage Suffix 60Hz Voltage Suffix
the (*) with the suffix from Coil Table. Modification page C7-8 24 Separate Control -96 200-240 -26
Order heater elements at $18 each Spare Parts C8 120 Separate -76 277 -66
from Section B Control 440-480 -46
550-600 -56

Discount Schedule JC12 C5


HP - NEMA Control AC Combination Starters

C
HPS25AA3296
HPS25AA3296
Non-Fusible Disconnect Switch - Type HPS
NEMA Type 1 3
Maximum Motor Starter General Purpose NEMA Type 3R 3
1
Horsepower Rating Ampere Disconnect Enclosure Raintight
NEMA 2
Size 200V 230V 460/575V Rating Ampere Rating Catalog No. Price Catalog No. Price
00 1 1/2 1 1/2 2 9 30 HPS02AA3610 * $ 786. HPS02RA3610 * $ 1018.
0 3 3 5 18 30 HPS05AA3610 * 874. HPS05RA3610 * 1104.
1 7 1/2 7 1/2 10 27 30 HPS10AA3610 * 922. HPS10RA3610 * 1152.
2 10 10 25 45 60 HPS25AA3610 * 1378. HPS25RA3610 * 1678.

Fusible Disconnect (200 & 230 Volts)


Max. Motor Horsepower Rating1 3
Disconnect Ampere NEMA Type 1
Dual Element Non-Time Rating General Purpose NEMA Type 3R 3
Starter
Fuse Delay Fuses Ampere
Enclosure Raintight
NEMA Fuse
2
Size 200V 230V 200V 230V Rating Switch Clips Catalog No. Price Catalog No. Price
00 1 /2 1
1 /2 1 1
1 /2 1
1 /2 9 30 30 HPS02AA3293 * $ 814. HPS02RA3293 * $ 1044.
0 3 3 3 3 18 30 30 HPS05AA3293 * 904. HPS05RA3293 * 1134.
1 5 7 1/2 3 3 27 30 30 HPS10AA3293 * 952. HPS10RA3293 * 1182.
1 7 1/2 ---- 7 1/2 7 1/2 27 30 60 HPS10AA3296 * 970. HPS10RA3296 * 1200.
2 10 15 ---- ---- 45 60 60 HPS25AA3296 * 1404. HPS25RA3296 * 1714.

Fusible Disconnect (460 & 575 Volts)


NEMA Starter Disconnect Ampere NEMA Type 1 NEMA Type 3R
Size 460V 575V 460V 575V Ampere Rating Fuse General Purpose Enclosure Raintight
2
Rating Switch Clips Catalog No. Price Catalog No. Price
00 2 2 2 2 9 30 30 HPS02AA3693 * $ 828. HPS02RA3693 * $ 1060.
0 5 5 5 5 18 30 30 HPS05AA3693 * 922. HPS05RA3693 * 1152.
1 10 10 7 1/2 7 1/2 27 30 30 HPS10AA3693 * 970. HPS10RA3693 * 1200.
1 ---- ---- 10 10 27 30 60 HPS10AA3696 * 990. HPS10RA3696 * 1222.
2 15 15 ---- ---- 45 60 30 HPS25AA3693 * 1414. HPS25RA3693 * 1722.
2 25 25 15 15 45 60 60 HPS25AA3696 * 1432 HPS25RA3696 * 1740.
Notes:
1. Motor Full load must not exceed starter continuous ampere rating. 3. For other Enclosure Types consult factory.
2. Prices includes starter complete with N.O. interlock, disconnect 2
0
switch less fuses, and 3-phase overload relay less heaters. 6

Ordering Information Coil Table


Use complete catalog number. Replace Engineering Data pages C10-14 60hz Voltage Suffix 60Hz Voltage Suffix
the (*) with the suffix from coil table. Modification pages C7-8 24 Separate Control -96 200-240 -26
Order heater elements at $18 each 120 Separate Control -76 277 -66
from Section page B32 440-480 -46
550-600 -56

C6 Discount Schedule JC12


Modifications and Parts NEMA Control - HP
Modifications
Factory Installation Price Addition - Change For Field Installation
Catalog No. as outlined on Page C9. Kit Catalog Number
For
Bulletin Type HP Enclosure Type Kits Only For
Description Number Size 1 4 & 12 Type 1 Enclosures Price
Cover Controls
Over Load Reset
6013, 6030
Hole plug for Internal Reset (10 per pack) KTM-26 $ 48.
& 6018
N/C N/C
Reset Button (one reset per kit) 6013 & 6030
6018
KHP-EC2
A60-
18.
36. C
Push Buttons & Selector Switches 306413
Start-Stop Push Buttons 6013, 00,0,1 $ 96. $ 264. KHP-4 60.
1
Hand-Off Auto Selector Switch 6030, &2 96. 264. KHP-8 60.
Forward-Reverse-Stop Selector Switch 6031, 96. 264. KHP-8 60.
Forward-Reverse-Stop Push Button & 7707 480. 480. KTM-18 300.
Pilot Lights
Without Electrical Interlocks, 6013, 90. 90. KTM5-4 66.
120V
Standard Transformer Type, 6030, 90. 90. KTM5-5 66.
240V
with Red Lens. 6031, 90. 90. KTM5-6 66.
480V
& 7707 90. 90. KTM5-7 66.
600V
Push Buttons & Selector Switches
Start-Stop Buttons 96. --- KTM5-1 60.
Hand-Off-Auto Selector Switch 6018 00,0,1 KTM5-3 60.
Pilot Lights &2
Without Electrical Interlocks, 120V 180. --- KTM5-4 132.
Standard Transformer Type, 240V KTM5-5 132.
with Red Lens. 480V KTM5-6 132.

Control Circuit
Auxillary Contacts
Extra N.O. Contact 132. 132. KHP-M10 60.
Extra N.O. and N.C. Contacts All All 198. 198. KHP-M11 90.
Two extra N.O. Contacts 198. 198. KHP-M20 90.
6013 Same as type TM,
Enclosure Kits
& 6030 see Section B

Power Circuit - For HPS Combination Starters


Fuse Clips-Kit includes 6 clips and mounting screws, without base for lower clips.2
Fuse Switch For Bulletin Type HP
Description Class Amp. Size Number Size Catalog No. Price
Base 30 Amp. 250 Volts R A63-452135-2 $ 48.
60 Amp. 250 Volts R A63-452133-2 48.
30 & 60 6018 00-2
1 30 Amp. 600 Volts R A63-452136-2 72.
8 60 Amp. 600 Volts R A63-452841-2 72.
6

Note:
1. Kits may be changed in the field from 3-position to 2-position operation. In addition to HAND-OFF-AUTO, four labels are included,
marked FORWARD-OFF-REVERSE: HIGH-OFF-LOW, TEST-LAG-LEAD, ON-OFF.

2. Lower Mounting Base for Fuse Clips- required only when converting a non-fusable unit to a fusable unit.

Discount Schedule JC12 C7


HP - NEMA Control Modification and Parts

Modifications
Factory Installed Price Addition For Field Installtion
Kit Catalog Number Discount
For Type HP Add to Schedule
Bulletin NEMA Type Enclosure JC12
Description Number Size 1, 4 & 12 Type 1 Only Price
Control Transformer - Includes Single Fused 120 Volt Secondary
VA Primary
Capacity Voltage Hertz 2
3 208 KTR67-16
Standard
C Capacity
50
240 & 480
600 6013 &
324. KTR67-2
KTR67-12
$216.
50 00-2
Extra 3 208 60 6018 KTR67-20
Capacity 150 240 & 480 576. KTR67-5 $264.
600 KTR67-25
Miscellaneous
Ambient Compensated Overload Relay All 00-2 24.
Fused Control Circuit:
Fuse Holder for one fuse All 00-2 264. KHP-F1 $48.
Fuse Holder for two fuses KHP-F2 72.

Enclosure Adaptor Kits:


Starter Mounting Plate KHP-EC1 $ 24.
Mtg. Plate with O/L Reset - Required with Enclosure Kit KHP-EC3 42.
Transformer Mtg. Plate 1 KTM-28 24.

Renewal Parts Size Discount Schedule JC80

00-2 KHP31-15 $ 124.


Replacement Overload
00-2 KHPA31-15 156.
Ambient Compensated
Replacement Power Contact Kit 00-1 KHP31-1 166.
2 KHP32-1 260.
Forward Side KHPR31-S 189.
00-1 Reverser
Reverse Side KHPR31-C 189.
00-1 Reverser
Notes: Forward Side KHPR32-S 283.
1. Reversing Starters require Size 2 Reverser
1-KHP-EC1 and 1-KHP- Reverse Side KHPR32-C 283.
EC3 with reset. Size 2 Reverser
2. Prices include larger cabinets
required for Bul. 6013 & 6030. Replacement Coil Kits Discount Schedule JC80
3. Includes one secondary fuse and Voltage Hertz
1
2 Primary Fuse Clips. 110-120 50 or 60 00, 0, 1 & 2 KTB174-1 $ 97. 8
208-240 50 or 60 KTB174-2 97. 6
440-480 50 or 60 KTB174-5 97.
550-600 50 or 60 KTB174-6 97.
380 50 or 60 KTB174-7 97.
277 50 or 60 KTB174-4 97.
24 50 or 60 KTB174-3 97.

C8 Discount Schedule JC12 & JC80


NEMA A-C Magnetic Starters NEMA Control - HP

Type of Contactor or Starter Enclosure Type Fuse Clip Size


HPC - Contactor A - NEMA 1 Fuse Clip Class R Fuse Clip
HP - Starter B - NEMA 2 03 - 30 ampere 93 - 30 ampere
HPRC - Reversing Contactor R - NEMA 3R 06 - 60 ampere 96 - 60 ampere
HPR - Reversing Starter P - NEMA 4- Painted Steel Class J Fuse Clip No number or
HPS - Combination Starter with Switch * W - NEMA 4-Stainless Steel 13 - 30 ampere 10 - no clips
* T - NEMA 12 16 - 60 ampere
U - Open Type
Type W & T enclosures are not
available with HPS combination

NEMA Size
starters. Use type TM for these
applications.
C
02 - Size 00
05 - Size 0
10 - Size 1 Pilot Light
25 - Size 2
Number of Poles
2 - Two Pole L - Indicates a standard red pilot light.
3 - Three Pole P - Indicates a "Push-To-Test" red
transformer type pilot light with
nameplates.
No Letter - Pilot light not required.

HPS 10 A A 3 6 03 - T46 L M10

Indicates Quantity of
Auxiliary Contacts
M10 = 1 N.O. Contact
M20 = 2 N. O. Contacts
M11 = 1 N.O. 1 N.C. Contact
Cover Control Indicates Type of
Bulletins 6013, 6018 & 7707 Overload Relay
A - Reset button in cover for A - Ambient compensated Suffix Without Transformer
overloads. No Letter - Non Ambient
Coil Volts & Hertz Suffix
B - Reset button and Hand-Off- compensated
Auto selector switch. 110-120/50 or 60 - 76
C - Reset button and Start-Stop 220-240/50 or 60 - 26
push button. 440-480/50 or 60 - 46
E - Selector switch no reset. 550-600/50 or 60 - 56
Disconnect Rating 200-208/50 or 60 - 86
F - Push button no reset.
O - None (no reset button in 2 - 240 Volts 277/50 or 60 - 66
cover) 4 - 480 Volts 24/50 or 60 - 96
6 - 600 Volts Suffix With Transformer
1 Bulletins 6030 & 6031
6
No number - No switch
A - Reset button in cover for (Secondary 110-120V)
6
overloads. Suffix
Transformer Primary
B - Reset button and Fwd.-Off- Volts & Hertz Standard 100 Watt
Rev. selector switch. Capacity Extra Capacity
C - Reset button and Fwd.- 220-240/50 or 60 - T26 - C26
Rev.-Stop push button. 440-480/50 or 60 - T46 - C46
O - None (no reset button in 550-600/50 or 60 - T56 - C56
cover) 200-208/50 or 60 - T86 - C86

C9
HP - NEMA Control Engineering Data
Type HP NEMA Sizes 00, 0, 1 & 2 Outline Drawings

31/2
7
3 /16 31/8

31/8
33/4
C

63/32

Contactor Type HPC Reversing Contactor Type HPRC

Provision for
#8/#10 screw (6)
31/8

51/8

33/8
2
221/32
5
/16 35/16

Starter Type HP Reversing Starters Type HPR

Power Wiring Accommodations Control Circuit


Provision for Ring Copper 0
Coil Burden
Wire Range Pressure Tongue Lugs 1 A-C Inductive Wire 2
3
Terminal Terminal Screw Continuous Terminal Size Screw
Line Load Wire Type Type Width in. Size Amperes Make Break Type Max. 2,3 Size Inrush Sealed
Copper Pressure Pressure
# 14 - #8 #14 - #4 .450 #10 - 32 5 880VA 40VA Saddle #12AWG #6 - 32 48VA 8.4VA
(Cu) Clamp
Notes:
1. UL specifies only one (1) wire per lug.
2. One or two stranded copper wires of same size,
or differing by two (2) gauge sizes.
3. Coil terminal wire size is #14 AWG maximum.

C10
Engineering Data NEMA Control - HP
Approximate Dimensions In Inches
Type HP NEMA Sizes 00, 0, 1 & 2 Outline Drawings

7
/8

D
B

C
5
/8 E C
A

NEMA Type 1 Enclosure NEMA Type 4 & 12 Enclosures

NEMA Type 1 Enclosure NEMA Type 4 & 12 Enclosure


Starter Without Transformer With Transformer Without Transformer With Transformer
Type A B C D E A B C D E A B C D E A B C D E
HP & HPC 63/4 91/2 61/4 73/4 5 125/8 91/2 61/4 73/4 11 71/4 11 67/8 101/2 4 131/8 11 67/8 101/2 6
HPR & HPRC 125/8 91/2 61/4 73/4 11 125/8 137/8 61/4 123/4 11 131/8 11 67/8 101/2 6 17 13 67/8 9 16

Type HPS NEMA Sizes 00, 0, 1 & 2 Outline Drawings

1
8
6

NEMA Type 1 Enclosure NEMA 3R-4&12 Enclosure

C11
HP - NEMA Control Engineering Data
Wiring Diagram
Type HP - Non-Combination Starter

CONTROL FUSE
WHEN USED

WIRE "A"

"A"

3 Pole, Three Phase 2 Pole, Single Phase

Connection For Pilot Devices


Cover Mounted Pilot Devices 3 Wire Control Remote Pilot Devices

Automatic Reset
Automatic reset operation should not
Connect To Coil Terminals be used with two wire control.

Start-Stop Pushbutton Pilot Light

Momentary Contact Pushbutton

Separate Control
0
Remove wire "A" when it is supplied. 2
3
Connect separate control lines to the
"1" terminal on the pilot device and
the "4" terminal on the starter.
3 Position Selector Switch 2 Position Selector Switch
(Remove Lead from Coil (Remove Lead from Coil Two or More Momentary
to Term No. 3) to Term No. 3) Contact Pushbutton Stations

C12
Engineering Data NEMA Control - HP
Wiring Diagram
Type HPR - Non-Combination Starters

Elementary Diagram Wiring Diagram Front View


Contactors "F" & "R" are Mechanically Interlocked When Limit Switches are used, remove Jumpers
"C" & "D" and connect per dotted lines.

Two Wire Control for Three Wire Control for Momentary


Maintained Pushbuttons Control Pushbuttons

Automatic Reset
Automatic reset operation should
not be used with two wire control.

0 Separate Control
2
3 Remove wire "A" when it is
supplied. Connect separate control
lines to the "1" terminal on the pilot
device and the "8" terminal on the
starter.

Pushbutton with Forward and Reverse


Buttons Electrically Interlocked

C13
HP - NEMA Control Engineering Data
Wiring Diagram
Type HPF - Combination Starter

C Control fuses
when used
Primary fuses
when used

Without Control Transformer With Control Transformer


(Wiring Diagram - Front View) (Wiring Diagram - Front View)

Connection For Pilot Devices


Connections for Cover Mounted or Remote Pilot Devices Dual voltage transformer is shipped as
shown connected for higher voltages.
Reconnect jumpers "J" per table for lower
OFF voltage.
HAND AUTO
Connect to Coil
ON OFF Terminals Voltage Connect L1 L2
H1 to H3
1 3 230 H1 H4
Pilot Light H2 to H4
TWO WIRE
CONTROL 1 3 460 H2 to H3 H1 H4
DEVICE All Single H1 H2
2 Position Selector Switch
(Remove Lead from Aux. 3 Position Selector Switch Primary Transformers
to Term No. 3) (Remove Lead from Aux. to Term No. 3) 3 4
1 0
2
START 3
START START Push-To-Test Pilot Light
1
1
2 2 Automatic Reset
STOP
STOP STOP
3 3 1 Automatic reset operation should not
be used with two wire control.
Two or More Momentary 3
Start-Stop Pushbutton Contact Pushbutton Stations Two Wire Control Device

C14
Push Buttons 100T
Index
Description Page Number
100T Push Buttons: Page
General Information ..................................................................... D2
Push Buttons - Std. & Mushrooms .............................................. D4
Key Operated - Push Pull Push Buttons ..................................... D5
Illuminated Push Buttons ............................................................. D6
Illuminated Push Pull Units ........................................................... D7 C
Pilot Lights & Press-to-Test Pilot Lights ...................................... D8
Selector Switches: 2 - 3 - 4 Position .......................................... D9 D
Illuminated Selector Switches: 2 & 3 Position ............................. D11
Joy Sticks: 3 & 5 Position ............................................................ D12
Assembled Push Button Units ...................................................... D13
Assembled Stations: 1 - 2 - 3 Elements ..................................... D13
Assembled Selector Switch Units ................................................ D14
Separate Enclosures: 1 - 16 Hole .............................................. D15
Legend Plates ............................................................................. D16
Accessories ................................................................................. D17
Dimensions & Ratings ................................................................. D18
Catalog Numbering System ......................................................... D19
STAK-LITE NEMA Type 1, 3R, 12, 4X, and 13 ............................. D21

D1
100T General Information
Joslyn Clark Type 100T Heavy Duty Push
Buttons are available in Standard,
Mushroom Head, Push Pull, and Key-
Operated . Standard and Jumbo Mush- Joslyn Clark Type 100T Heavy Duty
room Head Selector Switches are available in
All units are suitable for use in NEMA Both mushroom heads fit the same opera- Standard Knob, Chrome Lever, Key-
Type 1, 3, 3R, 4, 4X, 12, and 13 tor and come in black, red, green, and Operated, Joy Stick and Selector-Push.
applications when mounted in enclo- yellow. The diameter of the standard
sures rated for those same applications. head is 1-3/8" - jumbo head is 2-1/4" in The standard knob and chrome lever
Although not needed on all Type 4X diameter. switches are obtainable with two, three
applications, protective caps provide and four position operators. They come
improved resistance to some corrosive in 2 position maintained and spring
materials. They are not required by UL.
Illuminated Push Button return; 3 position maintained, spring
Plastic Lens are available in seven return form right to center, left to center
D NEMA 13 Oiltight and NEMA 4 Water-
tight integrity is assured by a unique
colors and in standard and mushroom
head (13/8") variety. The operator
, right and left to center; and 4 position
maintained. Key operated switches
collapsing neoprene diaphragm. Three combines a momentary push button and come in two or three position main-
neoprene gaskets in back of the panel pilot light in one unit. tained and spring return and all 4
insure a tight fit and flexibility for position switches are maintained.
different thickness enclosures. The Push-Pull
diecast housing fits both standard Both Illuminated and Non-Illuminated There are several cams for all selector
oiltight mounting holes with a 1-13/64" standard mushroom heads are available switches in order to accomplish
or 30.56mm diameter. in 2 position maintained operators. numerous types of circuits. Positive
indexing assures operating reliability.
Single circuit double break contact Key-Operated
blocks are made of tough clear plastic When the key-type cylinder lock is Up to eight single circuit contact blocks -
for easy contact inspection. Blocks are depressed with or without key inserted - four on either side - may be attached to
attached to the operator by a single the operator is locked down and can any operator with a single captive screw
captive screw and positioning pin to only be released by the key. A red and positioning pin on each block.
make installation quick and easy. Up to jumbo mushroom head can be field or
8 blocks may be stacked on each push factory installed for emergency stop A tip on the locking thrust washer
button operator (2 wide, 4 deep). Up to applications. Other types of key extends through the legend plate to the
6 blocks on each selector switch. operations are obtainable. panel, locking both plate and operator in
position.
Brushed aluminum legend plates are
held in place by a locking thrust washer Legend plates are of brushed aluminum
which extends through the plate into the with etched black lettering. An octago-
panel for easy alignment. Standard nal aluminum guard ring locks operator
legend plates are 1-7/8" square with on the panel adding to the look of
black etched in letters. Jumbo automo- quality.
tive size 2-1/2" square legends are also
available. Standard Knob
Interchangeable knobs are of high-
Standard Operators impact plastic in black, red, green,
Interchangeable snap-on, reusable tough yellow and blue. They fit tightly to an
molded-in-plastic cups, are available in inner white knob which provides an
Black, red, green, yellow, amber, blue, white, easy-to-see white index mark for the
and brown. Your choice of three octagonal, cap.
brushed aluminum guard rings comes in:
Unguarded -Button extends beyond ring for Standard Knob Illuminated
easy access. Selector Switch
Guarded -Ring is flush with button to
Available with seven interchangeable
prevent accidental operation.
colored lenses in both two position
Extended-Ring extends beyond button
maintained and three position main-
Guard making accidental operation unlikely.
tained and spring return.

D2
General Information 100T
Selector Switches Pilot Lights Contact Blocks
(600 Volt)
Chrome Lever Features
These selector switches have the same Contacts enclosed in a clear plastic
operating characteristics as the Standard housing
Knob model. An extended chrome lever, Fine silver contact tips
1-3/4" long, provides quick and positive Long life steel springs
operation with or without gloves. Same contact block for all operators
"Quick-Stack" assembly
Key-Operated "Easy-Access" terminals
Key-operated switches have the same "One-Block-At-A-Time" removal
Joslyn Clark Type 100T Heavy Duty Pilot
positive action as the Standard Knob and Easy contact mode identification
Lights are available in Standard and
UL listed
Chrome Lever types. Operators are ob-
tainable with many key removal positions.
Press-To-Test. A choice of power con-
figurations to match various shock and
D
There are special keys available for added Joslyn Clark Type 100T Heavy Duty Con-
vibration levels insure longer lamp life.
security. tact Blocks are designed to simplify in-
Plastic lenses come in red, green, yellow,
stallation and assure trouble-free opera-
amber, blue, white and clear. All lamps
tion.
Joy Stick have bayonet type bases.
All 3 position and 5 position maintained Contacts are enclosed in sturdy plastic to
and spring return joy sticks have the same There are four basic power configura-
prevent foreign material from entering the
positive action as the other selector tions.
block. The clear plastic allows easy con-
switches. A special joy stick model can be tact inspection. Contact tips are made of
supplied with a release button on top. 1 Transformer Type (120, 240 or 480
fine silver for high conductivity. Strong
This prevents movement of the joy stick Volts) uses a modular heavy-duty
resilient springs reduce contact bounce
until the button is depressed - an excellent transformer - 50 or 60 Hertz - to step
and assure long reliable operation. The 3/
safety feature. line voltage down to 6 volts for longer
4" blocks may be used on all operators
lamp life under high shock and vibra-
installed side by side and four in tandem.
Selector-Push tion conditions.
Selector-Push operators combine the ac- The single No. 8 tapped-head captive
2 Resistor Type (120 or 240 Volts)
tions of a selector switch and momentary screw and positioning pin on each block
drops voltage to 60 and 120 volts
push button. A rotating collar provides the make stacking fast and easy. Terminals
respectively to lengthen lamp life in
selectivity needed to provide for several are inclined for direct access and speedy
less severe applications.
functions in one operator. wiring also angled to provide extra wiring
room. A self-rising saddle assures a solid
3 Full-Voltage Types (6, 12, 24 or 120
vibration resistant connection at each ter-
Volts) are used in applications with
minal for two No. 12 copper wires. Indi-
little shock or vibration. AC and DC
vidual block removal is automatic without
rated.
possibility of the entire stack coming off
when the top block is removed.
4 Neon Type (120 Volts) will withstand
extremely heavy shock and vibration
Contact mode is readily identified. Nor-
conditions - use of clear and yellow
mally-Open contact blocks have green
lens is recommended. AC and DC
operators marked with both N.O. and
rated.
symbol. The normally-closed
blocks have red operators and are marked
Standard with N.C. and symbol.
Dome Lenses are made of thick plastic,
fluted to give wide visibility. They come in
red, green, yellow, amber, blue, white and
clear.

Press-To-Test
Features and colors are the same as
Standard Pilot Lights except the lenses
are tubular. A N.O. and a N.C. contact
block comes with unit.

D3
100T Push Buttons
Pushbuttons Standard Contact Blocks
Momentary Operation
Rod Catalog
NEMA Type 1, 4, 12, 13 Type Symbol Color Number Price
Catalog 1-N.O. Green 100T-CB10 $18.00
Operator Color Number Price 100T-CB01 $18.00
1-N.C. Red
Black 100T-PB1B 100T-CBH012
Red 100T-PB1R 1-N.O. 1-Green
Green 100T-PB1G Standard 100T-CB111 $36.00
Extended & 1-N.C. & 1-Red
Pushbutton Yellow 100T-PB1Y $32.00 Contact Block
Extended Amber 100T-PB1A 1. Consists of one 100T-CB10 and one 100T-CB01 packaged together.
Blue 100T-PB1E 2. Additional spring pressure for resistance to vibration.
White 100T-PB1W
Brown 100T-PB1N Contact Ratings
None 100T-PB1O $32.00 NEMA Amps. VA.
Black 100T-PB2B Rating Max.
D Red
Green
100T-PB2R
100T-PB2G
Desig. Volts Make Break Continuous Make Break
Maximum A-C Contact Rating Per Pole, 50 or 60 Hertz.
Yellow 100T-PB2Y $32.00
Flush 120 60 6
Flush Amber 100T-PB2A
Pushbutton A600 240 30 3 10 7200 720
Blue 100T-PB2E
White 100T-PB2W 480 15 1.5
Brown 100T-PB2N 600 12 1.2
None 100T-PB2O $32.00 Maximum D-C Contact Rating Per Pole
Black 100T-PB4B 125 1.1
1-3/8 inch Red 100T-PB4R $68.00 P600 250 0.55 5 138
Mushroom Green 100T-PB4G 301-600 0.2 120
Yellow 100T-PB4Y
1-3/8 inch None 100T-PB4O $60.00 Pushbutton Color Caps and Mushroom Head
Mushroom Head Black 100T-PB5B Color Caps for 1-3/8 inch 2-1/4 inch
2-1/4 inch
Mushroom Red 100T-PB5R $68.00 Flush Mushroom Head Mushroom Head
Green 100T-PB5G Unguarded or for Mushroom for Mushroom
Yellow 100T-PB5Y Guarded Push Buttons and Buttons and
Buttons Push Pull Units Push Pull
Selection Guide Units
Select push button operators from table above and contact blocks from table
on the right. Select legend plates from page D16. Catalog Catalog Catalog
Color Number Price Number Price Number Price
For complete units see pageD13. All units on this page will accept a total of Black 100T-BB 100T-BM4B 100T-BM5B
eight contact blocks. Red 100T-BR 100T-BM4R $8.00 100T-BM5R $8.00
Green 100T-BG 100T-BM4G 100T-BM5G
Yellow 100T-BY 100T-BM4Y 100T-BM5Y
Amber 100T-BA $1.00
Blue 100T-BE
Item Page Item Page White 100T-BW
Accessories D17 Pilot Lights D7 Brown 100T-BN
Legend Plates D16 Selector Switches D8 Mixed 100T-BM $8.00 100T-BM4M $32.00
Ratings and Dimensions D18 Special Devices D4
Assembled Units D13 Assembled Stations D13

Ordering Information
Complete Control Unit Consists Of:
OFF
Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-PB2B 100T-CB01 100T-L07

D4 Discount Schedule JC33


Push Buttons 100T
Special Purpose Push Button Units
Key Operated Push Button Push-Pull Units
This key operated push button is a chrome, unguarded unit that locks Push-Pull units are available as two position, maintained (buttons
in the depressed position. It must be unlocked with a key to release remain in the depressed position until manually released). Standard
it. Two keys are provided with each unit. units have 13/8 inch mushroom head operator.

Key Operated Push-Pull Unit


Push Button

Push-Pull Units
Description 1
Unit Locks in
Catalog No. Price
Comes with 13/8 inch Standard Mushroom Head. D
Depressed Legend Plate and Contact Blocks not included.
Position Key 100T-PB61 $104.00
Description Color 4 Catalog Number Price
Required to Legend Plate &
Release Contact Blocks Black 100T-PP4B $104.00
Chrome Unit Not Included Maintained Red 100T-PP4R 104.00
None 100T-PP40 96.00
1. 100T-BM6R 2 1/4 inch Red Mushroom Head available for
1. For colors not listed, or for units with 2 1/4 inch diameter Mushroom
this unit at $36.00 List Price each.
Heads, order with "none" and select desired Mushroom Head from
below.

Standard Contact Blocks


Rod Catalog
Type Symbol Color Number Price
1-N.O. Green 100T-CB10 $18.00 Mushroom Head Color Caps
100T-CB01 1-3/8 inch 2-1/4 inch
1-N.C. Red $18.00
100T-CBH013 Mushroom Head Mushroom Head for
1-N.O. 1-Green for Mushroom Mushroom Buttons
Standard 100T-CB112 $36.00 Buttons and Push and Push Pull Units
Contact Block & 1-N.C. & 1-Red
Pull Units
2. Consists of one 100T-CB10 and one 100T-CB01 packaged together.
3. Additional spring pressure for resistance to vibration. Catalog Catalog
Color Number 5 Price Number 6 Price
Black 100T-BM4B 100T-BM5B
Red 100T-BM4R $8.00 100T-BM5R $8.00
Green 100T-BM4G 100T-BM5G
Item Page Yellow 100T-BM4Y 100T-BM5Y
Accessories D17
Legend Plates D16 Mixed 100T-BM4M 32.00 100T-BM5M 32.00
Ratings and Dimensions D18 5. Packaged 1 per carton except 100T-BM4M contains one of each
color.
6. Packaged 1 per carton except 100T-BM5M contains one of each
color.
Ordering Information
Complete Control Unit Consists Of:

Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-PP4B 100T-CB01 100T-L30

Discount Schedule JC33 D5


100T Push Buttons
Illuminated Push Buttons
Illuminated Momentary Push Buttons comes with Standard Lens.
Legend Plate and Contact Blocks Not Included. Operator & Lenses
100T-PBLT1R
Lamp Lens Catalog
Type Voltage Number Color Number 1 Price
Selection Guide
120 Red 100T-PBLT1R $128.00 Select Illuminated push button operators from table at left and contact
AC only 755 Green 100T-PBLT1G 128.00 blocks from below. Units without lenses will accept either standard
50/60 Hz None 100T-PBLT1O 120.00 lens or mushroom lens. All units are provided with "unguarded" guard
240 Red 100T-PBLT2R $128.00 ring. Clear plastic guard 100T-PGR is available at $36.00 list price.
AC only 755 Green 100T-PBLT2G 128.00
50/60 Hz None 100T-PBLT2O 120.00 Select legend plates from pageD16
480 Red 100T-PBLT4R $128.00 For complete units, see pageD13
Transformer AC only 755 Green 100T-PBLT4G 128.00 All units on this page will accept a total of eight contact blocks.
50/60 Hz None 100T-PBLT4O 120.00
Standard Contact Blocks
D Red 100T-PBLR1R $104.00
Rod Catalog
120 60MB Green 100T-PBLR1G 104.00
AC DC None 100T-PBLR1O 96.00 Type Symbol Color Number Price

Red 100T-PBLR2R $104.00 1-N.O. Green 100T-CB1O $18.00


240 120MB Green 100T-PBLR2G 104.00 100T-CBO1
Resistor 1-N.C. Red $18.00
AC DC None 100T-PBLR2O 96.00 100T-CBHO14
Red 100T-PBLF1R $104.00 1-N.O. 1-Green
Standard 100T-CB113 $36.00
120 120MB Green 100T-PBLF1G 104.00 & 1-N.C. & 1-Red
AC DC None 100T-PBLF1O 96.00 Contact Block
Red 100T-PBLF6R $104.00 3 Consists of one 100T-CB1O and one 100T-CBO1 packaged together.
4 Additional spring pressure for resistance to vibration.
6 6MB Green 100T-PBLF6G 104.00
AC DC None 100T-PBLF60 96.00
Red 100T-PBLF7R $104.00 Standard Lenses and Mushroom Lenses
12 12MB Green 100T-PBLF7G 104.00
AC DC None 100T-PBLF7O 96.00 Standard Lenses 1-3/8 inch
for Guarded or Mushroom Lenses
Red 100T-PBLF8R $104.00 Unguarded Push for Illuminated Push
24 24MB Green 100T-PBLF8G 104.00 Buttons or Press- Buttons and Illuminated
Full Voltage AC DC None 100T-PBLF8O 96.00 to-Test Pilot Lights Push-Pull Units
Yellow 100T-PBLN1Y $104.00
Neon 2 120 NE51 Clear 100T-PBLN1C 104.00 Catalog Catalog
AC DC None 100T-PBLN1O 96.00 Color Number Price5 Number Price 6
1 Catalog number with lens are for standard lens. For colors not listed, or for Red 100T-LBR 100T-LBMR
1 3/8 inch mushroom lens, order with "none" and select desired standard or Green 100T-LBG 100T-LBMG
mushroom lens from table at right. Yellow 100T-LBY 100T-LBMY
2 Yellow or clear lens only recommended for neon unit. Amber 100T-LBA $8.00 100T-LBMA $8.00
Blue 100T-LBE 100T-LBME
Item Page Replacement Lamps
White 100T-LBW 100T-LBMW
Accessories D17 Voltage Catalog # Price Clear 100T-LBC 100T-LBMC
Legend Plates D16 6V 080 MB1 13.00
Ratings and Dimensions D18 Mixed 100T-LBM $56.00 100T-LBMM $56.00
12V 080 MB2 13.00
Assembled Units D13
24V 080 MB3 13.00 5. Packaged one per carton except 100T-LBM contains
48V 080 MB5 13.00 seven lenses, one of each color.
6. Packaged one per carton except 100T-LBMM
120V 080 MB7 13.00 contains seven lenses, one of each color.

Ordering Information
Complete Control Unit Consists Of:
MOTOR
STOP

Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-PBLT1R 100T-CB01 100T-L92

D6 Discount Schedule JC33


Push Buttons 100T
Illuminated Push-Pull Units
Illuminated Push-Pull Units (Maintained Position) Comes With and Without
13/8 inch Mushroom Head. Operator & Lenses
Legend Plate and Contact Blocks Not Included. 100T-PPLT1R

Lamp Lens Catalog


Type Voltage Number Color Number 1 Price
120 Red 100T-PPLT1R $164.00
AC only 755 Green 100T-PPLT1G 164.00
50/60 Hz None 100T-PPLT1O 156.00 Selection Guide
240 Red 100T-PPLT2R $164.00 Illuminated push-pull units are two position illuminated mushroom
AC only 755 Green 100T-PPLT2G 164.00 buttons which remain in the depressed position until manually re-
50/60 Hz None 100T-PPLT2O 156.00 leased. Select the operator from table at left and contacts from below.
Select legend plate from page D16.
480 Red 100T-PPLT4R $164.00
Transformer AC only 755 Green 100T-PPLT4G 164.00
50/60 Hz None 100T-PPLT4O 156.00
All units on this page will accept a total of eight contact blocks. D
Red 100T-PPLR1R $140.00
120 60MB Green 100T-PPLR1G 140.00 Standard Contact Blocks
AC DC None 100T-PPLR1O 132.00 Rod Catalog
Red 100T-PPLR2R $140.00 Type Symbol Color Number Price
240 120MB Green 100T-PPLR2G 140.00 1-N.O. Green 100T-CB1O $18.00
Resistor AC DC None 100T-PPLR2O 132.00 100T-CBO1
1-N.C. Red $18.00
Red 100T-PPLF1R $140.00 100T-CBHO14
120 120MB Green 100T-PPLF1G 140.00 1-N.O. 1-Green
AC DC None 100T-PPLF1O 132.00 Standard 100T-CB113 $36.00
Contact Block & 1-N.C. & 1-Red
Red 100T-PPLF6R $140.00
6 6MB Green 100T-PPLF6G 140.00 3 Consists of one 100T-CB1O and one 100T-CBO1 packaged together.
AC DC None 100T-PPLF6O 132.00 4 Additional spring pressure for resistance to vibration.
Red 100T-PPLF7R $140.00
12 12MB Green 100T-PPLF7G 140.00
AC DC None 100T-PPLF7O 132.00
Mushroom Lenses for
Red 100T-PPLF8R $140.00 Illuminated Push-Pull Units
24 24MB Green 100T-PPLF8G 140.00
Full Voltage 1 3/8 inch Mushroom
AC DC None 100T-PPLF8O 132.00
Lenses for Illuminate
Yellow 100T-PPLN1Y $140.00 Push-Pull Units
Neon 2 120 NE51 Clear 100T-PPLN1C 140.00
AC DC None 100T-PPLN1O 132.00 Catalog
Color Number Price 5
1 For colors not listed, order with "none" and select desired mushroom Red 100T-LBMR
lens form table at right. Green 100T-LBMG
2 Yellow or clear lens only recommended for neon unit.
Yellow 100T-LBMY
Amber 100T-LBMA $8.00
Item Page Blue 100T-LBME
Accessories D17 White 100T-LBMW
Legend Plates D16 Clear 100T-LBMC
Ratings and Dimensions D18 Mixed 100T-LBMM $56.00
5 Packaged one per carton except 100T-LBMM
contains seven lenses, one of each
color.

Ordering Information
Complete Control Unit Consists Of:

Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-PPLT1R 100T-CB01 100T-L30

Discount Schedule JC33 D7


100T Push Buttons
Pilot Lights and Press-To-Test Pilot Lights
4 4 Standard Lens
Pilot Lights Press-To-Test
Lamp Lens Catalog Catalog Pilot Light
Type Voltage Number Color Number1 Price Number 3 Price Operator & Lens
100T-PLT1R
120 Red 100T-PLT1R $128.00 100T-PTT1R $164.00
AC only 755 Green 100T-PLT1G 128.00 100T-PTT1G 164.00
50/60 Hz None 100T-PLT1O 120.00 100T-PTT1O 156.00
240 Red 100T-PLT2R $128.00 100T-PTT2R $164.00
AC only 755 Green 100T-PLT2G 128.00 100T-PTT2G 164.00 Pilot Light
50/60 Hz None 100T-PLT2O 120.00 100T-PTT2O 156.00 Pilot Lights are available in four different power
480 Red 100T-PLT4R $128.00 100T-PTT4R $164.00 configurations- transformer, resistor, full voltage
and neon types. Transformer types are available
Transformer AC only 755 Green 100T-PLT4G 128.00 100T-PTT4G 164.00
with 480, 240, and 120 volt primary voltages and
50/60 Hz None 100T-PLT4O 120.00 100T-PTT4O 156.00 all have a 6.3 volt secondary for long lamp life.
Red 100T-PLR1R $104.00 100T-PTR1R $140.00 They will withstand a considerable amount of
120 60MB Green 100T-PLR1G 104.00 100T-PTR1G 140.00 shock and vibration. The resistor type is available
D AC DC None 100T-PLR1O 96.00 100T-PTR1O 132.00
in 240 and 120 volt varieties with the resistor
dropping the voltage to 120 and 60 volts respec-
Red 100T-PLR2R $104.00 100T-PTR2R $140.00 tively. Full voltage units are available with 6, 12,
240 120MB Green 100T-PLR2G 104.00 100T-PTR2G 140.00 24, and 120 volt lamps. The neon bulbs burn less
Resistor brightly therefore it is recommended that only
AC DC None 100T-PLR2O 96.00 100T-PTR2O 132.00 yellow and clear lens be used for these units.
Red 100T-PLF1R $104.00 100T-PTF1R $140.00
120 120MB Green 100T-PLF1G 104.00 100T-PTF1G 140.00
AC DC None 100T-PLF1O 96.00 100T-PTF1O 132.00 Press-To-Test Lights
Red 100T-PLF6R $104.00 100T-PTF6R $140.00 Press-To-Test Lights are available in the same
6 6MB Green 100T-PLF6G 104.00 100T-PTF6G 140.00 four power configurations as the standard pilot
lights - Transformer, resistor, full voltage, and
AC DC None 100T-PLF6O 96.00 100T-PTF6O 132.00 neon. They are furnished pre-wired with a nor-
Red 100T-PLF7R $104.00 100T-PTF7R $140.00 mally open and a normally closed contact. As
12 12MB Green 100T-PLF7G 104.00 100T-PTF7G 140.00 shown in the diagram below it will allow you to test
the lamp without interfering with the normal op-
AC DC None 100T-PLF7O 96.00 100T-PTF7O 132.00
eration of the pilot light.
Red 100T-PLF8R $104.00 100T-PTF8R $140.00
24 24MB Green 100T-PLF8G 104.00 100T-PTF8G 140.00 L1 L2
Full Voltage AC DC None 100T-PLF8O 96.00 100T-PTF8O 132.00 SIGNAL
CONTACT
Yellow 100T-PLN1Y $104.00 100T-PTN1Y $140.00 L1 L2
Neon 2 120 NE51 Clear 100T-PLN1C 104.00 100T-PTN1C 140.00
AC DC None 100T-PLN1O 96.00 100T-PTN1O 132.00
1 For colors not listed, order with "none" and select desired lens from table below.
2 Yellow or clear lens only recommended for neon unit.
3 Catalog number with lens are for standard lens. For colors not listed or for 1 3/8 inch mushroom
lens order with "none" and select desired standard or mushroom lens from table below. (Transformer type shown as typical)
4 Legend Plate Not Included.
5 For Replacement Lamps see page D6.
Standard Lenses and Mushroom Lenses

Standard Lenses for Standard Lenses for 1 3/8 inch Mushroom


Pilot Lights Guarded or Unguarded Lenses for Illuminated
Buttons or Press-To- Press-To-Test
(Purchased after Test Pilot Lights Pilot Lights
Jan. 1997)
Catalog Catalog Catalog
Color Number Price 5 Number Price 6 Number Price 7
Red 100T-LR 100T-LBR 100T-LBMR
Green 100T-LG 100T-LBG 100T-LBMG
Yellow 100T-LY 100T-LBY 100T-LBMY
Press-To-Test Pilot Light Amber 100T-LA $8.00 100T-LBA $8.00 100T-LBMA $8.00
Operator & Lens Blue 100T-LE 100T-LBE 100T-LBME
100T-PTT1R White 100T-LW 100T-LBW 100T-LBMW
100T-LC 100T-LBC 100T-LBMC
Clear
Mixed 100T-LM $56.00 100T-LBM $56.00 100T-LBMM $56.00

5 Packaged 1 per carton except 100T-LM contains seven lenses one of each color.
6 Packaged 1 per carton except 100T-LBM contains seven lenses one of each color
($58.80/ ctn).
7 Packaged 1 per carton except 100T-LBMM contains seven lenses one of each color
$58.80/ctn).

D8 Discount Schedule JC33


Push Buttons 100T
Selector Switches 2-3-4 Position Non-Illuminated
Selector Switches
Legend Plate and Contact Blocks not included

Black Knob Operator 1 2 Crome Lever Operator Key Operator


3 3
Catalog Cam Catalog Cam Catalog Cam 3 Key 4
Type Number Code Price Number Code Price Number Code Removal Price
2 Positioned $116.00
Black Knob
100T-SS2MB 1 $44.00 100T-SL2MC 1 $44.00 100T-SK2M 1 A
Maintained
100T-SS2MB1
2 Position
Spring Return 100T-SS2RB 1 68.00 100T-SL2RC 1 68.00 100T-SK2R 1 C 140.00
Right To Center
3 Positioned 100T-SS3MB 3,4,5, 44.00 100T-SL3MC 3,4,5, 44.00 100T-SK3M 3,4,5, A $116.00
Maintained 6, or 7 6, or 7 6, or 7
3 Position
Spring Return
Right To Center
100T-SS3RB 3,4,5,
6, or 7
68.00 100T-SL3RC 3,4,5,
6, or 7
68.00 100T-SK3R 3,4,5,
6, or 7
C 140.00 D
Chrome Lever 3 Position
100T-SL2MC1 Spring Return 100T-SS3LB 3,4,5, 68.00 100T-SL3LC 3,4,5, 68.00 100T-SK3L 3,4,5, C 140.00
Left To Center 6, or 7 6, or 7 6, or 7
3 Position
Spring Return 100T-SS3BB 3,4,5, 68.00 100T-SL3BC 3,4,5, 68.00 100T-SK3B 3,4,5, C 140.00
Rt. & Lt. to Ctr. 6, or 7 6, or 7 6, or 7
4 Position 100T-SS4MB 8 44.00 100T-SL4MC 8 44.00 100T-SK4M 8 A $116.00
Maintained

1 Available in other colors Change "B" in operator catalog number to "R" for Red, "G" for Green, "Y" for Yellow,
Key Operated or "E" for Blue.
2 Available without Knob Change "B" in operator Catalog number to "O" and select knob from table below.
100T-SK3M
3 Cam code is a part of catalog number: Example 100T-SS3MB3 See table of cam developments.
4 Key Removal code is part of catalog number. Example: 100T-SK3B3C See Key Removal table below.
Key Spare Parts Color Plastic Knobs
- For Standard Key Operator use 100T-3095 @ $17.00 using JC80 disc. sch.
- For 501 Key Operator use 100T-CH501 @ $28.00 using JC80 disc. sch. Standard Plastic
Knob for Knob
Key Removal Codes Operated Selector
Two Position Three Position Four Position Switches
Maintained Spring Return Left Right Catalog
Key Left Right Center Right Left Center Right Left Center Center Right Color Number Price 5
Removal Black 100T-SB $8.00
Code Red 100T-SR 8.00
L (Left) Yes No ----- ----- Yes No No Yes No No No Green 100T-SG 8.00
R (Right) No Yes No Yes No No Yes No No No Yes Yellow 100T-SY 8.00
C (Center) ----- ----- Yes No No Yes No ----- ----- ----- ----- Blue 100T-SE 8.00
A (All) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Mixed 100T-SM 40.00
NOTE: No 501 Key is available for above Key Operators Selector Switches. To order add "5" for 5 Packaged one per carton except
501 Key to the end of the catalog number add $24.00 to list price. 100T-SM contains one of each
Example: 100T-SK2M1A5. color knob.

Ordering Information
Complete Control Unit Consists Of:

Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-SS2MB1 100T-CB01 100T-L52

Discount Schedule JC33 D9


100T Push Buttons
Selector Switches
Contact Block Switching Sequence and Selection
2 Position Selector Switch
Selector Position
Location of Contact Block Cam Code 1
Contact Block Maintained Spring Return
(Front View)
Catalog Rod Left Right Center Right
Number Symbol Color
100T-
N.O. CB10 Green O X O X
Left
D N.C.
N.O.
CB01
CB10
Red
Green
X
O
O
X
X
O
O
X
Right
N.C. CB01 Red X O X O
Cam codes are same for maintained X = Contact Closed
or spring return operation. O = Contact Open

3 Position Selector Switch


Selector Position Selector Position Selector Position Selector PositionSelector Position
Location of Contact Block Cam Code 3 Cam Code 4 Cam Code 5 Cam Code 6 Cam Code 7
Contact Catalog Rod Left Center Right Left Center Right Left Center Right Left Center Right Left Center Right
Block Number Symbol Color
(Front View)
100T-
N.O. CB10 Green O O X O O X X O O O O X O O X
Left
N.C. CB01 Red X O O O X O O X O X X O X O O

Right N.O. CB10 Green O O X O O X X O O X O O O O X


N.C. CB01 Red X O O O X O O X O O X X O X O
Cam Codes are the same X= Contact Closed: O= Contact Open
for maintained or spring
return operation.

Standard Contact Blocks


Rod Catalog
Type Symbol Color Number Price
4 Position Selector Switch 1-N.O. Green 100T-CB1O $18.00
Selector Position 1-N.C. Red 100T-CBO1 $18.00
Location of Contact Block Cam Code 8 100T-CBHO12
Contact Block 1-N.O. 1-Green
Left Left Right Right Standard 100T-CB111 $36.00
(Front View) & 1-N.C. & 1-Red
Catalog Rod Center Center Contact Block
Number Symbol Color 1. Consists of one 100T-CB10 and one 100T-CB01 packaged together.
100T- 2. Additional spring pressure for resistance to vibration.
N.O. CB10 Green O O X O
Left
N.C. CB01 Red X O O O
N.O. CB10 Green O X O O
Right
Item Page
N.C. CB01 Red O O O X
Accessories D17
Cam codes are same for maintained X = Contact Closed Legend Plates D16
or spring return operation. O = Contact Open Ratings and Dimensions D18
Assembled Units D14

D10 Discount Schedule JC33


Push Buttons 100T
Illuminated Knob Operated Selector Switches
Illuminated Selector Switches Legend Plate and Contact Blocks Not Included.
Transformer Type
3,4
Operator with Red Lens
5
Type Voltage Catalog No. Cam Code Price
2 Postions 120 100T-S12MT1R 1 $140.00
Maintained 240 100T-S12MT2R 1 140.00
480 100T-S12MT4R 1 140.00
2 Position 120 100T-S12RT1R 1 $164.00
Spring Return 240 100T-S12RT2R 1 164.00
Right to Center 480 100T-S12RT4R 1 164.00
3 Position 120 100T-S13MT1R 3,4,5, $140.00
Maintained 240 100T-S13MT2R 6, or 7 140.00
480 100T-S13MT4R 140.00
3 Position 120 100T-S13BT1R 3,4,5, $164.00
Spring Return
Rt. & Lt. to Ctr.
240
480
100T-S13BT2R
100T-S13BT4R
6, or 7 164.00
164.00
D
100T-S12MT1R
3. Available without lens. Change last "R" in operator catalog number to "O" and
select knob from table below.
4. Available in other colors Change "R" in operator catalog number to "G" for
Green, "Y" for Yellow, "A" for Amber, "E" for Blue, "W" for White, "C" for Clear.
5. Cam Code is part of catalog number Example: 100T-S13MT1R3. See table
of cam developments on pageD10.
Illuminated Selector Switches
Standard Lenses for Illuminated
The Illuminated Selector Switch combines the functions of a standard Selector Switches
selector switch and a pilot light in one unit. Power supply types and
selector functions other than those shown are available. The same Standard Plastic Lens for Knob
cams as used with the standard selector switch are available for the Operated Illuminated Selector
Illuminated Selector Switch. See page D10 for cams and contact Switches 6
sequences for two and three position selector switches. All units will Color Catalog No. Price
accept a total of eight contact blocks. Select legend plates from Red 100T-SLR
pageD16. Green 100T-SLG
Yellow 100T-SLY $8.00
Amber 100T-SLA
Blue 100T-SLE
White 100T-SLW
Standard Contact Blocks Clear 100T-SLC
Rod Catalog Mixed 100T-SLM $59.00
Type Symbol Color Number Price
1-N.O. Green 100T-CB1O $18.00 6. Packaged one per carton except 100T-SLM
contains seven lenses, one of each color
100T-CBO1 ($58.80/ctn).
1-N.C. Red $18.00
100T-CBHO12
1-N.O. 1-Green
Standard 100T-CB111 $36.00
Contact Block & 1-N.C. & 1-Red
Item Page
1. Consists of one 100T-CB1O and one 100T-CBO1 packaged together. Accessories D18
2. Additional spring pressure for resistance to vibration Legend Plates D17
Ratings and Dimensions D19

Ordering Information
Complete Control Unit Consists Of:

F O
F N
O Complete
+ + = Push Button
Unit

Operator Contact Blocks Legend Plate


100T-S12MT1R 100T-CB01 100T-L52

Discount Schedule JC33 D11


Push Buttons 100T
Special Devices - Joy Stick Joy Stick Operator
The Joy Stick Operator is available in three (left-center-right) and five (left-
up-right-down-center) position, maintained and spring return (to center)
types. They are also available with a release button on the end of the
operator which must be depressed in order to operate the joy stick.

Joy Stick - Contact Blocks and Legend Plate Not Included


Without Release Button With Release Button
Type Catalog No. Price Catalog No. Price
3 Positions
Maintained 100T-JS3M $212.00 100T-JP3M $260.00
3 Position
Spring Return 100T-JS3B 212.00 100T-JP3B $260.00
to Center

D 5 Position
Maintained 100T-JS5M 212.00 100T-JP5M $260.00
100T-JP5M Joy Stick Unit 5 Position
Spring Return 100T-JS5B 212.00 100T-JP5B $260.00
to Center

Three Position Joy Stick - Contact Sequence Five Position Joy Stick - Contact Sequence
Contacts 1 Contacts 4 Joy Stick Position
Joy Stick Position (Front View)
Location Type (Front View) Location Type
(Front and Rod (Front and Rod Left Up Center Down Right
Type View) Symbol Color Left Center Right Type View) Symbol Color c
N.O. N.O.
Three Position, Left Green X O O Five Position, Green O O O X O
Left
Maintained and N.C. Maintained and N.C.
Spring Return Red O O X Spring Return Red O X O O O
to Center, With N.O. to Center, With N.O.
or Without Green O O X or Without Green O O O O X
Right Right
Release Button N.C. Release Button N.C.
Red X O O Red X O O O O
1. Contact Blocks are not supplied. Order contact blocks from table 4. Contact Blocks are not supplied. Order contact blocks from table
below. below.

Standard Contact Blocks


Rod Catalog
Type Symbol Color Number Price
Item Page
1-N.O. Green 100T-CB1O $18.00
Accessories D18
1-N.C. Red 100T-CBO1 $18.00
Legend Plates D17
100T-CBHO13
Ratings and Dimensions D19
1-N.O. 1-Green
Standard 100T-CB112 $36.00
Contact Block & 1-N.C. & 1-Red
2. Consists of one 100T-CB1O and one 100T-CBO1 packaged together.
3. Additional spring pressure for resistance to vibration.

Ordering Information
Complete Control Unit Consists Of:

Complete
+ + = Joy Stick
Unit

Operator Contact Blocks Legend Plate


100T-JS3M 100T-CB10 100T-L30

D12 Discount Schedule JC33


100T Push Buttons
Assembled Push Buttons Assembled Push Buttons Stations
Assembled Push Buttons Stations In Surface mounted Enclosures
Description of Elements NEMA 13 1 NEMA 4 2
Sheet Steel Stainless Steel
Catalog Catalog
Number Price Number Price
Single element Stations
START (black guarded
push button) 100T-S1-1 $156. 100T-W1-1 $288.
START (black 21/4" mush-
Assembled Push Buttons, including Contact Blocks as shown. room push button) 100T-S1-2 192. 100T-W1-2 324.
(Does not include Legend Plate) STOP (red unguarded
push button) 100T-S1-3 156. 100T-W1-3 288.
Red Catalog STOP (red Mushroom
Operator Type Symbol Color Number Price unguarded push button
with lockdown) 100T-S1-4 192. 100T-W1-4 324.
Unguarded
1-N.O.

1-N.C.
Black

Red
100T-PB1B-10X

100T-PB1R-01X
$50.00

$50.00
STOP (red 21/4" mush-
room push button) 100T-S1-5 192. 100T-W1-5 324.
D
OFF-ON (black knob
1-N.C. Black 100T-PB1B-11X $68.00 selector switch) 100T-S1-6 168. 100T-W1-6 300.
HAND-OFF-AUTO (black
1-N.O. Red 100T-PB1R-11X $68.00
knob selector switch) 100T-S1-7 168. 100T-W1-7 300.
1-N.O. Black 100T-PB2B-10X $50.00 FWD-OFF-REV (black
knob selector switch) 100T-S1-8 168. 100T-W1-8 300.
1-N.C. Black 100T-PB2B-11X $68.00 Two Element Stations
Guarded START-STOP (black
Red 100T-PB2R-11X $68.00 guarded-red unguarded
1-N.O. Green 100T-PB2G-11X $68.00 push buttons) 100T-S2-1 240. 100T-W2-1 372.
START-STOP (black
1 3/8" 1-N.C. Black 100T-PB4B-11X $104.00 guarded-red 13/8" mush-
Mushroom room push buttons) 100T-S2-2 276. 100T-W2-2 408.
1-N.O. Red 100T-PB4R-11X $104.00 FORWARD-REVERSE
(black guarded-black
2 1/4" 1-N.C. Black 100T-PB5B-11X $104.00
guarded push buttons) 100T-S2-3 240. 100T-W2-3 372.
Mushroom OPEN-CLOSE (black
1N.O. Red 100T-PB5R-11X $104.00
guarded-black guarded
Illuminated 1-N.C. push buttons) 100T-S2-4 240. 100T-W2-4 372.
Push Button UP-DOWN (black guarded
120V Trans- Red 100T-PBLT1R-11X $164.00 -black guarded push
former Type 1-N.O. buttons) 100T-S2-5 240. 100T-W2-5 372.
Three Element Stations
Illumated 1-N.C. FORWARD-REVERSE-
Push Button STOP (black guarded-
120V Re- Red 100T-PBLR1R-11X $140.00 black guarded-red
sistor Type unguarded push buttons) 100T-S3-1 324. 100T-W3-1 528.
1-N.O.
OPEN-CLOSE-STOP
(black guarded-black
guarded-red unguarded
push buttons) 100T-S3-2 324. 100T-W3-2 528.
UP-DOWN-STOP (black
guarded-black guarded-red
unguarded push buttons) 100T-S3-3 324. 100T-W3-3 528.
START-STOP-JOG (black
guarded-red unguarded-
black guarded push
buttons) 100T-S3-4 324. 100T-W3-4 528.
START-STOP-MOTOR
RUN (black guarded-red
Assembled 100T Push Button Stations unguarded push buttons-
red 120 volt transformer
The most commonly used push button stations are available assembled in unguarded pilot light) 100T-S3-5 384. 100T-W3-5 588.
NEMA Type 13 (oiltight and dustight) sheet steel and in NEMA 4 (water-
tight) stainless steel enclosures. 1 Use NEMA 13 enclosures for applications requiring NEMA1.
2 Protective watertight boots are not required for indoor (non-freezing)
For custom control stations not listed, order operators, contact blocks, applications. If for outdoor (freezing) use, order boots as separate items,
from page D17.
nameplates, and enclosures as separate items.

Discount Schedule JC33 D13


Push Buttons 100T
Assembled Selector Switches
Assembled Selector Switches, Including Contact Blocks as shown

D
2 Position Selector Switch (Does not include Legend Plate)
Contacts Selector Position Complete Catalog No. and Price for Assembled Unit
Location Type (Front View) Black Knob Operator Chrome Lever Operator
(Front and Rod Left Center Right Catalog Catalog
Type View) Symbol Color No. Price No. Price
N.O.
2 Position Green O -- X 100T- 100T-
Maintained Left
N.C.
Red X -- O SS2MB1-11X $80.00 SL2MC1-11X $80.00
2 Position N.O.
Spring Re- Green -- O X 100T- 100T-
Left
turn Right to N.C.
Center Red -- X O SS2RB1-11X 104.00 SL2RC1-11X 104.00

3 Position Selector Switch (Does not include Legend Plate)


Contacts Selector Position Complete Catalog No. and Price for Assembled Unit
Location Type (Front View) Black Knob Operator Chrome Lever Operator
(Front and Rod Left Center Right Catalog Catalog
Type View) Symbol Color No. Price No. Price
N.O.
3 Position Green O O X 100T- 100T-
Maintained Left
N.C.
Red X O O SS3MB3-11X $80.00 SL3MC3-11X $80.00
3 Position N.O.
Green O O X 100T- 100T-
Spring Return Left
Right & Left to N.C.
Red X O O SS3BB3-11X 104.00 SL3BC3-11X 104.00
Center

4 Position Selector Switch (Does not include Legend Plate)


Contacts Selector Position
Complete Catalog No. and Price for Assembled Unit
Location Type (Front View)Black Knob Operator Chrome Lever Operator
(Front and Rod Left Left Right Right Catalog Catalog
Type View) Symbol Color Center Center No. Price No. Price

N.O.
Green O O X O
Left
N.C.
4 Position Red X O O O 100T- 100T-
Maintained
N.O.
Green O X O O SS4MB8-22X $116.00 SL4MC8-22X $116.00
Right
N.C. Red O O O X

D14 Discount Schedule JC33


100T Push Buttons
Separate Enclosures
NEMA Type 13, and NEMA Type 4 Stainless Steel surface mount-
ing enclosures are available with from one through sixteen element
openings. All enclosures will accommodate non-illuminated opera-
tors with up to two contact blocks (1 per side). Consult factory for
stations with 7 through 16 elements.

NEMA 13, Sheet Steel


NEMA 4, Stainless Steel D
315/32
21/4 Separate Enclosures
9 7
/32 X /32 + + Enclosures Only, Without Elements
MTG. HLS. NEMA 13 1 NEMA 4 2
Sheet Steel Stainless Steel
Surface Mounted Surface Mounted
Enclosure Enclosure
Number Of Catalog Price Catalog Price
Element Number Each Number Each
H/M
H 1 100T-S1 $84. 100T-W1 $216.
2 100T-S2 96. 100T-W2 228.
3 100T-S3 108. 100T-W3 312.
4 100T-S4 132. 100T-W4 408.
5 100T-S5 156. 100T-W5 600.
6 100T-S6 156. 100T-W6 600.
9 100T-S9 192. 100T-W9 744.
11/32 + + + 12 100T-S12 240. 100T-W12 900.
Max. 16 100T-S16 300. 100T-W16 1188.

Only on
NEMA 4 1. Use NEMA 13 enclosures for applications requiring NEMA 1.
2. Protective watertight boots are not required for indoor (non-
freezing) applications.
If for outdoor (freezing) use, order boots as separate items
3
313/64 /4 14 NPT For from page D17.
+
1,2,&3 Unit Stat.
11/2
1-111/2 NPT
For 4,5,&6 Stat.

NEMA 13, Sheet Steel NEMA 4, Stainless Steel


Number of Surface Mounted Enclosure Number of Surface Mounted Enclosure
Elements W H D W/M H/M Elements W H D W/M H/M
1 6-13/16 6-1/4 1 6-13/16 6-1/4
2 6-13/16 6-1/4 2 9-1/16 8-1/2
3 3-15/32 9-1/16 3-13/64 2-1/4 8-1/2 3 15
3- /32 11-5/16 13
3- /64 1
2- /4 10-3/4
4 11-5/16 10-3/4 4 13-3/16 12-5/8
1 1 1
5 15- /16 14- /2 5 15- /16 14-1/2
15 3 15
6 16- /16 16- /8 6 16- /16 16-3/8

Ordering Information
Select enclosure desired by catalog number. Select Pilot Devices from 100T section.

Discount Schedule JC33 D15


Push Buttons 100T
Legend Plates
Standard Legend Plates - Available with markings listed below at $3.60 list each.

Non-Standard Legend Plates - Can be provided with special markings at $15.60 list
each.

MOTOR O
STOP
FF N
O

D
Catalog No. Catalog No. Catalog No. Catalog No.
Standard Size Jumbo Size Standard Size Jumbo Size
Marking 1-7/8" Square 1 2-1/2" Square 2 Marking 1-7/8" Square 1 2-1/2" Square 2
For Push Buttons and Pilot Devices For Two Position Selector Switches
Start 100T-L01 100HF-N701 Man-Auto 100T-L51 100HF-N751
Stop 100T-L02 100HF-N702 Off-On 100T-L52 100HF-N752
Fast 100T-L03 100HF-N703 For-Rev 100T-L53 100HF-N753
Slow 100T-L04 100HF-N704 Safe-Run 100T-L54 100HF-N754
Open 100T-L05 100HF-N705 Jog-Run 100T-L55 100HF-N755
Close 100T-L06 100HF-N706 High-Low 100T-L56 100HF-N756
Off 100T-L07 100HF-N707 Open-Close 100T-L57 100HF-N757
On 100T-L08 100HF-N708 Up-Down 100T-L58 100HF-N758
Up 100T-L09 100HF-N709 Hand-Auto 100T-L59 100HF-N759
Down 100T-L10 100HF-N710 Start-Stop 100T-L60 100HF-N760
Raise 100T-L11 100HF-N711 Run-Jog 100T-L61 100HF-N761
Lower 100T-L12 100HF-N712 Start-Jog 100T-L62 100HF-N762
Low 100T-L13 100HF-N713 For Three Position Selector Switch
High 100T-L14 100HF-N714 Hand-Off-Auto 100T-L71 100HF-N771
Out 100T-L15 100HF-N715 Auto-Off-Hand 100T-L72 100HF-N772
In 100T-L16 100HF-N716 For-Off-Rev 100T-L73 100HF-N773
Jog 100T-L17 100HF-N717 Open-Off-Close 100T-L74 100HF-N774
Inch 100T-L18 100HF-N718 Man-Off-Close 100T-L75 100HF-N775
Reset 100T-L19 100HF-N719 For-Safe-Rev 100T-L76 100HF-N776
Run 100T-L20 100HF-N720 Run-Safe-Jog 100T-L77 100HF-N777
Forward 100T-L21 100HF-N721 Jog-Safe-Run 100T-L78 100HF-N778
Reverse 100T-L22 100HF-N722 Up-Off-Down 100T-L79 100HF-N779
Jog Forward 100T-L23 100HF-N723 For Four Position Selector Switches
Jog Reverse 100T-L24 100HF-N724 1-2-3-4 100T-L31 100HF-N731
Emergency Stop 100T-L25 100HF-N725
For Joy Stick Operator
Push Stop 100T-L41 100HF-N741
Pull Start (Blank) 100T-L30 100HF-N730

Cycle Start 100T-L83 100HF-N783 1 Character height is 1/8 inch on Standard Legend Plate.
Cycle Stop 100T-L84 100HF-N784 2 Character height is 1/4 inch on Jumbo Legend Plate.

Power On 100T-L91 100HF-N791 NOTE:


Motor Run 100T-L92 100HF-N792 Use the trim washer if no legend plate is used. Discard the trim
Motor Stop 100T-L93 100HF-N793 washer when using a legend plate.
Light Indicates 100T-L94 100HF-N794
Motor Running
(Blank) 100T-L30 100HF-N730

D16 Discount Schedule JC33


100T Push Buttons
Accessories
Description Catalog Number Price
Guard Rings for Push Buttons
Unguarded 100T-1GR $6.00
Guarded 100T-2GR 6.00
Extended Guard 100T-3GR 12.00
Standard Mushroom Head Guard 100T-4GR 80.00
Jumbo Head Guard 100T-5GR 80.00
Half Guarded 100T-7GR 12.00
Lens Guard for Press-To-Test
Pilot Lights
Plastic 100T-PGR 12.00
Metal 100T-MGR 12.00
Lens Guard For Pilot Lights, Metal 100T-LGR 6.00
Water Resistant Boots for Push Buttons
Black 100T-PBB 24.00
D
Red 100T-PBR 24.00
Green 100T-PBG 24.00
Yellow 100T-PBY 24.00
Translucent 100T-PBT 24.00
Translucent Water Resistant Boots for Illuminated
Push Buttons, Pilot Lights, and Press-To-Test Pilot 100T-PLTB 36.00
Lights

Translucent Water Resistant Boots for Knob


Operated Standard and Illuminated Selector 100T-SSTB 36.00
Switches
Mechanical Interlock for Push Buttons (Interlocks
two buttons so they cannot be simultaneously 100T-PBM 36.00
depressed)
Maintained Interlock for Push Buttons (Interlocks
two buttons so that when one is depressed, the 100T-PBMA 36.00
other is released-maintained operation)

Lock-Down attachment for Push Buttons 100T-PBL 36.00

Lock-Down attachment for Push Buttons with


Boots 100T-PBLB 36.00

Wobble Stick Operator for Push Buttons 100T-WS 36.00

Guard Ring Wrench (for Octagonal Guard Rings) 100T-F1X3 108.00

Special Screwdriver (Positively mates with Contact


Block assembly screw) 100T-SD 36.00
4
1
5
Chrome Lever attachment for Selector-Push Units 100T-SPL 24.00

Key (2-3-4 Position /Non-Illuminated Selector Switch) 100T-3095 14.40


Hole Plug, 1 & 13-Grey 1X4 12.00
Hole Plug, NEMA 4-Chrome 2X4 12.00

Discount Schedule JC33 D17


100T Push Buttons
Dimensions and Ratings

Minimun Centerline Clearance Contact Ratings


Panel Drilling Amp. Rating VA.
1-5/16 2 NEMA Max.
1/4 Drill Rating Volts Make Break Continuous Make Break
1-7/8 2-1/4 9/16 Maximum A-C Contact Rating Per Pole, 50 or 60 Hertz
120 60 6
240 30 3
1-13/64 Dia. A600 10 7200 720
1-7/8 2-1/4 480 15 1.5
600 12 1.2
Lighted Maximum D-C Contact Rating Per Pole
Unit
2-1/4 2-1/4 125 1.1 138
.090 P600 250 0.55 5 138
Lighted .180 301-600 0.2 120
Unit
1-7/8 2-1/4
1.290
Lighted Max. Panel Spacers
Unit
1-5/16 7/8 3 Thickness, In. Required
1-7/32 Dia.
1-7/16 2-1/4 4
1/16 3
1/8 2
3/16 1
Enclosure or grounded metal part
Panels thicker than 3/16" must be
Depth Push Buttons Push-Pull Counter Bored
Behind & Selector Units (Non- Illuminated
Panel Switches Illuminated) Units (all)
A5 21/32 1-11/32 11/16 Rear of Mounting Panel Rear of Mounting Panel

B --- --- 1-3/32


C6 3/4 3/4 3/4 A C A B C

Notes:
1. Use the trim washer if no legend plate is used. Discard the trim
washer when using a legend plate.
2. Must be 1-5/8" for 100-HF Legend Plate
3. Must be 1-1/8" for 2-1/4" Mushroom Head
Contact Power Contact
4. When using 100-HF Legend Plate, both horizontal and vertical
centerlines between operators must be 2-1/2" min. Block Supply Block
When using either 2-1/4" mushroom head or lever selector
switch, both horizontal and vertical centerlines between opera-
tors must be 2-1/4" min.
5. Depth when three neoprene spacers are used. Reduce depth
by 1/16 inch for each spacer omitted.
6. Depth per contact block. Maximum contact stack depth is three
(3) inches.

D18 Discount Schedule JC33


Push Buttons 100T
Catalog Numbering System
Push Button & Push-Pull
Bulletin Number Assembled

100T - PB1 B - 10 X
Operator Type Color Cap Contacts
PB1 - Unguarded - Push Button *B- Black See Contact Block Chart
PB2 - Guarded - Push Button *R- Red on Page D20
PB4 - Std. Mushroom Head - Push Button *G- Green
PB5 - Jumbo Mushroom Head - Push Button *Y- Yellow
PB61 - Key Operated Push Button A-
E-
Amber (Orange)
Blue
D
PP4 - Push-Pull 2 Position Mushroom Head
N- Brown
W- White
C- Clear
O- No Cap
* Colors Available For
Mushroom Heads

Selector Switch
Operator Type Position Operator Function
SS - Selector Switch Knob (standard) 2 - 2 Position Selector Switch M- Maintained
SL - Selector Switch Lever 3 - 3 position Selector Switch R- Spring Return from Right
SK - Selector Switch Key 4 - 4 Position Selector Switch L- Spring Return from Left
JS - Joy Stick B- Spring Return from Both
JP - Joy Stick w/Release Button Left and Right

100T - SS 2 M B 1 - C - 11 X
Bulletin Number Assembled
Cam Number Key Removal Position
Color Insert See Tables on Cat. Key Selector Switch Only Contacts
B - Black E - Blue on Page 10 L - Left Only See Contact Block Chart
R - Red C - Chrome Lever R - Right Only on Page D20
G - Green O - No Cap C - Center Only
Y - Yellow A - All Positions

Pilot Lights & Press To Test Lights


Bulletin Number

100T - PL R 2 A
Operator Type Power Supply Voltage Lens Color
PL - Std. Pilot Light T- Transformer Type 1 - 120 6- 6 R -Red E - Blue
PT - Press-to-Test Pilot Light R- Resistor Type 2 - 240 7 - 12 G -Green W - White
F- Full Voltage Type 4- 480 8 - 24 Y - Yellow C - Clear
N- Neon Type A - Amber O - No Lens

Discount Schedule JC33 D19


Push Buttons 100T
Catalog Numbering System
Illuminated Push Button & Push-Pull
Power Supply
T- Transformer Type
Operator Type R- Resistor Type
PBL - Lighted Push Button F- Full Voltage Type
PPL - Lighted Push-Pull N- Neon Type

Bulletin Number Assembled

100T - PBL T 1 R 11 X
D
Voltage Lens Color Contacts
1 - 120 6- 6 R- Red E- Blue See Contact Block Table
2 - 240 7 - 12 G- Green W- White Below
4- 480 8 - 24 Y- Yellow C- Clear
A- Amber O- No Lens

Illuminated Selector Switch


Operator Designation Position Operator Type Contacts
S1 - Selector Illuminated 2- 2 Position T- Transformer Type See Contact Block Table
(Knob Type Only) 3- 3 Position R- Resistor Type Below
F- Full Voltage Type
N- Neon Type
Bulletin Number Assembled

100T - S1 3 M T 1 R 3 - 10 X
Operator Function Voltage Lens Color Cam Function
M- Maintained 1 - 120 6- 6 R- Red E - Blue See Cam Numbers on
R- Spring Return From Right 2 - 240 7 - 12 G- Green W - White Page 10
L- Spring Return From Left 4- 480 8 - 24 Y- Yellow C - Clear
B- Spring Return From Both A- Amber O - No Lens
(Left and Right)

Contact Table Contact Ratings


To Order These As Amp. Rating Va.
For This Contact Catalog Separate Units NEMA Max.
Arrangement Suffix Code Qty. Catalog No. Rating Volts Make Break Continuous Make Break
1 N.O. -10 1 100T-CB10 Maximum A-C Contact Rating Per Pole, 50 or 60 Hertz
1 N.C. -01 1 100T-CB01 120 60 6
2 N.O. -20 2 100T-CB10 240 30 3
A600 10 7200 720
2 N.C. -02 2 100T-CB01 480 15 1.5
600 12 1.2
1 N.O., 1 N.C. -11 1 100T-CB11
Maximum D-C Contact Rating Per Pole
125 1.1 138
2 N.O., 2 N.C. -22 2 100T-CB11
P600 250 0.55 5 138
301-600 0.2 120

D20 Discount Schedule JC33


General Information STAK-LITE ®

Joslyn Clark's STAK-LITE® will tell you what is happening. From far or near, the bright LITE-BARTM
status lights instantly communicate the information you need.

Joslyn Clark's STAK-LITE® is a versatile and high quality monitoring component for the VISUAL
FACTORY. The units are designed to NEMA 1, 3R, 12, 4X, and 13 standards which make them
ideally suited for harsh environments commonly found on the factory floor.

Joslyn Clark's STAK-LITE® status indicators come in six colors: Red, Green, Amber, Blue,Frosted
White, and clear, and are available for either steady or flashing operation.

Available in 9 MM or 15 MM
Filament Bulbs
D
Led Lamps available in 6 Colors

6 Lens Colors: Red, Blue, Green, Amber, Frosted


White, and Clear

Modular design permits easy conversion to any


number of lenses from 1 to 6 high

Steady or flashing operation

Easy to change lamps. (Lift off entire stak of lenses


and change any bulb no tools required)

Readily available standard type MB replacement


lamps. Two (2) spare bulbs are furnished in the
cover on 9MM Bulb units

NEMA Type 1, 3R, 12, 4X, and 13

Panel mount or 3/4" NPT conduit mounting

Panel mounting interchangeable with competitive


units

D22

D21
100T Notes
Stak-Lite Technical Data

Codes, standards and approvals: All Stak-Lites are UL listed and CSA
certified. As supplied, assembled Stak-Lites are rated as Type 1, 12, or 13 enclo-
sures and may be conduit or panel mounted.

Environments: To convert to Type 3R, knock out one of the two bolt holes in the
mounting base. Stak-Lites modified for Type 3R cannot be panel mounted as panel
mounting would interfere with drainage.

For Type 4 and 4X applications specify the 4SL Series Stak-Lites.

Operating Temperature: -25 Deg. C to +45 Deg. C


D
Relative Humidity: Rated for operation in non-condensing relative humidities
between 5% and 95%.

Lamps: Ba 15D, Ba9s

Audible output / frequency: 95dB sound pressure level at 1.0 foot @ 2800Hz.
tone frequency 30.5 Hz.

Electrical Wiring: All wiring is copper. Wiring and insulation is rated at 300V,
105 Deg. C.

In leads out version, wire destination is determined by length. The shortest black wire
coming out from the base goes to the bottom lens; the longest black wire goes to the
bottom lens. Leads out Stak-Lites with the flasher option have only one white wire
common to all positions.

Table 1
Height

Number of
Lenses 0 1 2 3 4 5 6
With
Leads "out" ---- 5" 8" 11" 14" 17" 20"
With terminal
block "or" leads 5" 8" 11" 14" 17" 20" 23"
out with base
options
Maximum height is 23" from bottom of mounting base to top of cap.
Terminal referencing: Optional terminal boards feature two vertical sets of connectors
numbered 1-6 and one horizontal set of connectors numbered 1-6 and "N". These numbers
correspond with lens position, with 1 being the top lens, 2 the next lens down, and so on.
The set of vertical connectors on the left is for black (hot) leads; the set on the right is for
white (neutral) leads. The horizontal set is for customer connections.

Note: Strobe flashes 75 times/minute.

D22
STAK-LITE ® Status Indicator
Status Indicating System - Asembled
Total SL System SL System SL System W/Audible SL System W/Audible
Number With 18" Wire Leads With Terminals Signal and 18" Wire Leads Signal & Terminals
Lamps Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
1 SL1-*1 $150. SLT1-*1
$230. SLA1-* 1
$290. SLTA1-* 1
$370.
2 SL2-*1 236. SLT2-*1 316. SLA2-*1 376. SLTA2-*1 456.
3 SL3-*1 322. SLT3-*1 402. SLA3-*1 462. SLTA3-*1 542.
4 SL4-*1 408. SLT4-*1 488. SLA4-*1 548. SLTA4-*1 628.
5 SL5-*1 494. SLT5-*1 574. SLA5-*1 634. SLTA5-*1 714.
6 SL6-*1 580. SLT6-*1 660. SLA6-*1 720. SLTA6-*1 800.

NEMA 4X For NEMA 4X add 4 in front of the catalog number and multiply list price time 1.5. NEMA 4X
not available with audible alarm. D
Flasher Installed: Add $100.00 total for each set of 3 lights, add letter F after color light that should flash.
Example: SL4-120-RFGFACF
Strobe Installed: Add $300.00 per light and add letter S after light that is to be a strobe.
Example: SL5-120-CSRGBA Note: Strobe flashes 75 times/minute.
When ordering, specify light colors in sequence from top to bottom on the STAK-LITE®
Strobe and Flasher can be added to the same unit in any sequence.
Top Cap: Standard color is black,
Cap to match top color, add suffix "V" after designated color.
Example: SL3-120-RVAG (Add $40.00 to list)
Chrome Cap, Add suffix "CR" to the end of the catalog number.
Example: SL3-120-RAG-CR (Add $40.00 to list)
Special Lamp: If 15mm lamp is required, put a "B" after voltage; example:(SL1-120B-R).
Special Lamp: If Led lamp is required, put an "L" after voltage; example:(SL1-120L-R). (Consult Factory for Pricing)
Modular System And Accessories
Description Catalog No. Price
Flasher Assemblly (3 Lts. Max. per Flasher) KSLF- * $ 100.00
Strobe Light (120V, 240V only) KSLS- * 1 300.00
Gasket for Base and Lens (Qty. 2) KSLG 6.00
Chrome Retaining Cap KSLC 40.00
Retaining Cap to match Lens Color KSLC- 1 50.00
Lens Assembly KSLL09- 1 75.00
Lens Only (Does not include post or lamp holder) KS-1 40.00
Mounting Base KSLB 40.00
Terminal Board Assembly KSLT 80.00
Audible Alarm Assembly (97 DB’s at 1 foot) KSLA- * 140.00
Lamp Holder only for 9mm KSL-09 34.00
Lamp Holder only for 15mm KSL-15 34.00
- For mounting flange and extending tubing, see accessories page D26
- For wire leads 36" or 48" there is a $20.00 adder
1
Ordering Information * A.C. Voltage Color
* Select Lamp Voltage From Chart 6 VAC -6 Red - R
1
Select One Color For Each Lens From Chart 12 VAC -12 Amber - A
Example: 24VAC -24 Green - G
SL4-120 RAGC is 4 Lamp 120 VAC 48VAC -48 Clear - C
STAK-LITE® Assembled With 120VAC -120 Blue - B
Red, Amber, Green and Clear Lens 240VAC -240 White - W
Black - K

D23
Status Indicator STAK-LITE ®
STAK-LITE Mounted On Switch Panel 1

Total STAK-LITE Mounted On Extended Tubing Color - Specify In


Number Wired Base w/ Switches In Inches Sequence From Top
Lights Cat. No. Price Cat. No. Length Price To Bottom

1 SLE1- $462. R Red

2 SLE2- 548. 00 - N/C A Amber

3 SLE3- 634. + 04 04" $52. + G Green

D 4 SLE4- 720. 08 08" 72. C Clear

5 SLE5- 806. 16 16" 92. B Blue

6 SLE6- 892. W White

1. NEMA 1 Enclosure complete with one switch for every light and 9 ft. - 120 VAC fused line cord. All units include
(3) Position Switch. Up-Steady, Center-Off, Down-Flashing.

EXAMPLE: (4) Lights - Red, Amber, Green, and Blue, with 8" Extended Tubing.
SLE4-08-RAGB $792.00 List.

Audible Alarm: Add (A) after 3rd. digit of catalog number, and add $140.00 List.
Example: SLEA3-04-R,A,G $826.00 List.

Strobe : Add Letter (S) after the letter for the color that is to be a strobe and add 300.00 List.
Example: SLE4-08-RS,A,G,B $1092.00 List.

Colored Top Cap: For top cap made from colored lens material add letter (V) after light color that matches
lens color and add $50.00 List.
Example: SLE4-08-RV,A,G,B $842.00 List.

Accessories STAK-LITE Replacement Lamps


AC or DC (9MM Lamp)*
Description Cat. No. Length Price Voltage Wattage Catalog No. Price
6 Volt 4.2 Watt KRB09-6 $13.00
Mounting Flange KSLH $30.00 12 Volt 6 Watt KRB09-12 13.00
24 Volt 6 Watt KRB09-24 13.00
Extended Tubing KSLP04 04" 24.00 48 Volt 6 Watt KRB09-48 13.00
120 Volt 6 Watt KRB09-120 13.00
KSLP08 08" 34.00
Replacement Strobe Lamp
KSLP16 16" 44.00 Any Voltage 4000V Tube
KRZ 84.00
Strobe Tube Zennon

*For 15MM Bulbs, see page D26

D24 Discount Schedule JC35


STAK-LITE ® Status Indicator

Light Frame Assembly Kits


Light Frame assembly kits are furnished without lamps or lenses, making them very easy to
stock and modify. For a complete STAK-LITE ® order (1) Light Frame and separate lenses
and lamps (15mm) for every height of frame.

Light Frame Assembly Kits


SK Version W/18" Wire Leads SKT Version WTerminal Block
Frame Frame Frame
Height Catalog No. Price Height Catalog No. Price
1 SK1 $ 110. 1 SKT1 $190.
D 2
3
SK2
SK3
156.
202.
2
3
SKT2
SKT3
236.
282.
D
4 SK4 248. 4 SKT4 328.
5 SK5 294. 5 SKT5 374.
6 SK6 340. 6 SKT6 420.

With Wire Leads With Terminal


Block

Light Frame Assembly Kits With Audible Alarm


SKA Version W/120VAC Audible Alarm and 18" Leads SKTA Version W/120 VACAudible Alarm and Term
Frame Frame
Height Catalog No. Price Height Catalog No. Price
1 SKA1 $250. 1 SKTA1 $330.
2 SKA2 296. 2 SKTA2 376.
3 SKA3 342. 3 SKTA3 422.
4 SKA4 388. 4 SKTA4 468.
5 SKA5 434. 5 SKTA5 514.
6 SKA6 480. 6 SKTA6 560.

Light Frame Assembly Kits With Flasher


SK Version W/18" Leads & Flasher SKT Version W/Terminal Block & Flasher
Frame Frame
Height Voltage Catalog No. Price Height Catalog No. Price
1 24 VAC SK1-24AC-F $210. 1 SKT1-24AC-F $290.
1 120 VAC SK1-120AC-F 210. 1 SKT1-120AC-F 290.
2 24 VAC SK2-24AC-F 256. 2 SKT2-24AC-F 336.
2 120 VAC SK2-120AC-F 256. 2 SKT2-120AC-F 336.
3 24 VAC SK3-24AC-F 302. 3 SKT3-24AC-F 382.
3 120 VAC SK3-120AC-F 302. 3 SKT3-120AC-F 382.
4 24 VAC SK4-24AC-F 348. 4 SKT4-24AC-F 428.
4 120 VAC SK4-120AC-F 348. 4 SKT4-120AC-F 428.
5 24 VAC SK5-24AC-F 394. 5 SKT5-24AC-F 474.
5 120 VAC SK5-120AC-F 394. 5 SKT5-120AC-F 474.
6 24 VAC SK6-24AC-F 440. 6 SKT6-24AC-F 520.
6 120 VAC SK6-120AC-F 440. 6 SKT6-120AC-F 520.

Discount Schedule JC35 D25


Status Indicator STAK-LITE ®

Light Frame Assembly Kits With Top Strobe


SK Version W/18" Leads & One Top Mounted Strobe SKT Version W/Terminal Block & One Top Mounted
Strobe
Frame Frame
Height Voltage Catalog No. Price Height Catalog No. Price
1 240 VAC SK1-240AC-S $410. 1 SKT1-240AC-S $490.
1 120 VAC SK1-120AC-S 410. 1 SKT1-120AC-S 490.
2 240 VAC SK2-240AC-S 456. 2 SKT2-240AC-S 536.
2 120 VAC SK2-120AC-S 456. 2 SKT2-120AC-S 536.
3 240 VAC SK3-240AC-S 502. 3 SKT3-240AC-S 582.
3 120 VAC SK3-120AC-S 502. 3 SKT3-120AC-S 582.
4 240 VAC SK4-240AC-S 548. 4 SKT4-240AC-S 628.
4 120 VAC SK4-120AC-S 548. 4 SKT4-120AC-S 628.
D 5
5
240
120
VAC
VAC
SK5-240AC-S
SK5-120AC-S
594.
594.
5
5
SKT5-240AC-S
SKT5-120AC-S
674.
674.
6 240 VAC SK6-240AC-S 640. 6 SKT6-240AC-S 720.
6 120 VAC SK6-120AC-S 640. 6 SKT6-120AC-S 720.

Separate Lamps
Separate Lenses (AC or DC) 9MM
Color Catalog No. Price Voltage Catalog No. Price
Red KS-R $40. 6 VAC KRB09-6 $13.00
Amber KS-A 40. 12 VAC KRB09-12 13.00
Green KS-G 40. 24 VAC KRB09-24 13.00
Clear KS-C 40. 48 VAC KRB09-48 13.00
Blue KS-B 40. 120 VAC KRB09-120 13.00
White KS-W 40. 240 VAC KRB09-240 13.00
• One Lamp required for every height of
• One Lens required for every height of frame. frame.

Separate Lamps
(AC or DC) 15MM
Voltage Catalog No. Price
6 VAC KRB15-6 $20.00
STAK-LITE Options 12 VAC KRB15-12 20.00
24 VAC KRB15-24 20.00
Description Catalog No. Price 48 VAC KRB15-48 20.00
120 VAC KRB15-120 20.00
3/4" Conduit Mounting Flange 1 KSLH $30. 240 VAC KRB15-240 20.00
Extended Tubing - 4" KSLP04 24.
Extended Tubing - 8" KSLP08 34. • One Lamp required for every height of
frame.
Extended Tubing - 16" KSLP16 44.
1 The standard unit can be panel mounted directly to any flat surface
through two 5/16" DIA. holes. To elevate the unit, use standard 3/4"
conduit or JCC Extended Tubing, and the KSLH mounting flange.
Separate LED Lamps

For LED Replacement


Lamps, Consult Factory

D26 Discount Schedule JC35


STAK-LITE ® Dimensions

Height "A" With Terminals


Number Of Lenses 0 1 2 3 4 5 6
Dimension "A" 5" 8" 11" 14" 17" 20" 23"

Height "A" With 18" Wire Leads


Number Of Lenses 1 2 3 4 5 6
Dimension "A" 5" 8" 11" 14" 17" 20"

Discount Schedule JC35 D27


Index Pump Controllers

Description Page Number


Duplex and Triplex Pump Controllers .................... E2
Pump Modifications ............................................. E3
Numbering System ............................................... E4

General Application Standard Equipment


Joslyn Clark Duplex and Triplex Controllers may be All Standard Three Phase Controllers include the following:
specified with a wide variety of modifications to meet
Heavy guage steel enclosure, NEMA Type 2 Drip-Proof
the following application requirements:
construction
Water Booster Systems Corrosion resistant gray baked enamel offers superior
Condenser Water Recirculation resistance to the damp corrosive environment of pump
Chilled Water Recirculation rooms
0
3 Heat Transfer Single disconnect switch with separate power fuse blocks
3 Boiler Feed for each starter
Cooling Tower Two or Three Disconnect Switch types also
Sump Pump available
Sewage Pumps
Air Compressors Two Duplex or Three Triplex NEMA Starters with overload
Fish Farm Ponds heaters for each pump motor
Control transformer with primary and secondary fuses
Hand-Off-Automatic selector switch for each starter

E1
AC Starters Pump Controllers
As standard all 3 phase controllers include transformer and H-O-A selector switch for each starter.

Duplex Controller with Single Disconnect Duplex Controller with Two Disconnect
Switch & Two sets of Fuse Blocks Switches & Two sets of Fuse Blocks
E NEMA Starters NEMA Starters
Maximum Fuse Maximum Fuse
NEMA Horsepower Clips NEMA Type 2 NEMA Horsepower Clips NEMA Type 2
Cont. Rating Amp Enclosure Cont. Rating Amp Enclosure
Size 200V 230V Rating Catalog No. Price Size 200V 230V Rating Catalog No. Price
0 3 3 30 DSNE00BE3203- * $2420. 0 3 3 30 DDNE00BE3203- * $2760.
C 1
1
5
71/2
71/2
71/2
30
60
DSNE10BE3203-
DSNE10BE3203-
* 2520.
2700.
1
1
5
71/2
71/2
71/2
30
60
DDNE10BE3203-
DDNE10BE3206-
* 2820.
3200.
* *
2 10 15 60 DSNE20BE3203- * 2880. 2 10 15 60 DDNE20BE3206- * 3360.
3 25 30 100 DSNE30BE3203- * 6560. 3 25 30 100 DDNE30BE3201- * 7720.
4 40 50 200 DDNE40BE3202- * 10300.
460-575V 460-575V

E 0
1
5
10
30
30
DSNE00BE3603-
DSNE10BE3603-
*
*
$2480.
2580.
0
1
5
10
30
30
DDNE00BE3603-
DDNE10BE3603-
*
*
$2820.
2880.
2 15 30 DSNE20BE3603- * 2760. 2 15 30 DDNE20BE3603- * 3260.
2 25 60 DSNE20BE3606- * 2920. 2 25 60 DDNE20BE3606- * 2920.
3 50 100 DSNE30BE3601- * 6560. 3 50 100 DDNE30BE3601- * 7720.
4 100 200 DDNE40BE3602- * 10300.

Triplex Controller with Single Disconnect Triplex Controller with Three Disconnect
Switch & Three sets of Fuse Blocks Switches & Three sets of Fuse Blocks

NEMA Starters NEMA Starters


Maximum Fuse Maximum Fuse
NEMA Horsepower Clips NEMA Type 2 NEMA Horsepower Clips NEMA Type 2
Cont. Rating Amp Enclosure Cont. Rating Amp Enclosure
Size 200V 230V Rating Catalog No. Price Size 200V 230V Rating Catalog No. Price
0 3 3 30 TSNE00BE3203- * $3020. 0 3 3 30 TTNE00BE3203- * $3620.
1 5 71/2 30 TSNE10BE3203- * 3780. 1 5 71/2 30 TTNE10BE3203- * 4380.
1 71/2 71/2 60 TSNE10BE3206- * 3900. 1 71/2 71/2 60 TTNE10BE3206- * 4700.
2 10 15 60 TSNE20BE3206- * 4080. 2 10 15 60 TTNE20BE3206- * 4880.

460-575V 460-575V
0 5 30 TSNE00BE3603- * $3100. 0 5 30 TTNE00BE3603- * $3700.
1 10 30 TSNE10BE3603- * 3860. 1 10 30 TTNE10BE3603- * 4460.
2 15 30 TSNE20BE3603- * 3980. 2 15 30 TTNE20BE3603- * 4780.
2 25 60 TSNE20BE3606- * 4140. 2 25 60 TTNE20BE3606- * 4940.

Note: For circuit breaker in place of switch, add $84.00 list per switch.
For circuit breaker in place of power fuse block, add $160.00 list per block. 3
8
0
Ordering Information Coil Table
Select Catalog Number and Price for largest Motor HP size. If different HP sizes are required Specify Voltage/Hertz Suffix
with modification "S" from page E3. 220-240/60 or 220/50 - T26
Pump Controllers include heaters for NEMA Starters 440-480/60 or 440/50 - T46
When ordering specify each motor full load amps, HP and Voltage for correct selection of motor 550-600/60 or 550/50 - T56
overload protection. 200-208/60 - T86
Use complete catalog number. Replace the (*) with the suffix from coil table.

E2 Discount Schedule J46


Pump Controllers Modifications
Duplex Triplex Change
Enclosure Price Price Letter To: Typical Catalog Number
Type 2 Enclosure - Standard $N/C $N/C A
Type 3R Enclosure 300. 400. R
Type 3R Double Door Enclosure CF CF D
Type 12 Enclosure 300. 400. T
Type 4 Stainless Steel CF CF W
Type 4 Painted Steel CF CF P
Type 4 Painted Steel With Double Door CF CF S

Cover Controls For Each Starter DS NE 20 A E 3 6 0 -T 46 - - -

Internal O/L Reset Only $N/C $N/C O


H-O-A With Internal O/L Reset - Standard N/C N/C E
H-O-A With External O/L Reset 120. 180. B
Start-Stop PB'S Internal O/L Reset 200. 300. F
Start-Stop PB'S W/External O/L Reset 320. 480. C

Modifications

Duplex Alternating Relay $400. ---- A E


Triplex Alternating Relay Pumps 1 & 2 Only ----- $400. A1
Triplex Alternating Relay Pumps 2 & 3 Only ----- 400. A2
24 Hour Alternation 400. 960. A3
Manual Alternation Selector Switch 160. 560. A4
Min. Run Timer All Pumps 560. 840. B
Min. Run Timer Pump 1 280. 280. B1
Min. Run Timer Pump 2 280. 280. B2
Min. Run Timer Pump 3 ----- 280. B3
Time Delay Start All Pumps 560. 840. C
Time Delay Start In Auto Pump 1 280. 280. C1
Time Delay Start In Auto Pump 2 280. 280. C2
Time Delay Start In Auto Pump 3 ----- 280. C3
Off Delay Timer All Pumps 560. 840. D
Off Delay Timer Pump 1 280. 280. D1
Off Delay Timer Pump 2 280. 280. D2
Off Delay Timer Pump 3 ----- 280. D3
Elapsed Time Meter For Each Pump Running 400. 600. E
Mounting Feet 12" 200. 200. F1
Audible & Visible Alarm With Silencing Circuit 600. 600. H1
- Signal Source Separate
Timer For Delayed Alarm Activation 280. 280. J
- Specify Alarm To Be Delayed
Surge Arrester 400. 400. K
Light - Power On 140. 140. L1
Light - Pump Run For Each Pump 280. 420. L2
Light High Water Level 140. 140. L3
Light Low Water Level 140. 140. L4
Light - Specify Function 140. 140. L5
N.O. Pump Run Contacts 200. 300. M
Power Fuses CF CF P1
4 Pole Relay - Specify Function 400. 400. R1
Alternate Starter Sizes
Alternate Starter Size For Pump 1 N/C N/C S1
Alternate Starter Size For Pump 2 N/C N/C S2 *
Alternate Starter Size For Pump 3 N/C N/C S3 *
4 0
8 Pressure Switches Mounted On Outside Of * 4
5 Enclosure 3
5-150 PSI, Bourdon Type 500. 500. T1
10-200 PSI, Bourdon Type 500. 500. T2
10-300 PSI, Bourdon Type 500. 500. T3
18-116 PSI Diaphragm Type 400. 400. T4
15-232 PSI Diaphragm Type 400. 400. T5
2-60 PSI, For Low Suction Alarm 500. 500. T6

CF = Consult Factory * Specify Contactor size for a Duplex Pump (ie: S220=pump 1 NEMA size 1)

E3
Numbering System Pump Controllers
Duplex & Triplex Pump Control Catalog Numbering
DS = Duplex Single Switch 2 Fuse Blocks A = Alternating Relay J = Timer For Delayed Alarm
DD = Duplex Double Switch 2 Fuse Blocks A1 = Triplex Alternating Relay Activation - Specify Alarm
DO = Duplex No Switch or Fuse Block Pumps 1 & 2 Only To Be Delayed
(Non-Combination) A2 = Triplex Alternating Relay K = Surge Arrestor
TS = Triplex Single Switch 3 Fuse Blocks Pumps 2 & 3 Only L1 = Light - Power On
TD = Triplex Double Switch 3 Fuse Blocks A3 = 24 Hour Alternating Relay L2 = Light - Pump Run For Each
TT = Triplex Three Switch 3 Fuse Blocks A4 = Manual Alternation Selector Pump
SS = Simplex Switch & Fuse Block Switch L3 = Light High Water Level
B = Min. Run Timer All Pumps L4 = Light Low Water Level
B1 = Min. Run Timer Pump 1 L5 = Light - Specify Function
B2 = Min. Run Timer Pump 2 M = N.O. Pump Run Contacts
B3 = Min. Run Timer Pump 3 P1 = Power Fuses
C = Time Delay Start In Auto R1 = 4 Pole Relay - Specify
All Pumps Function
C1 = Time Delay Start In Auto S1* = Alternate Starter Size For
NE = NEMA Starters - HP Sizes 0-2 Pump 1 Pump 1
TM Size 3 & 4 C2 = Time Delay Start In Auto S2* = Alternate Starter Size For
E C3
Pump 2
= Time Delay Start In Auto
Pump 2
S3* = Alternate Starter Size For
Pump 3 Pump 3
D = Off Delay Timer All Pumps Pressure Switches
D1 = Off Delay Timer Pump 1 Mounted
B = Type 2 Enclosure D2 = Off Delay Timer Pump 2 On Outside Of Enclosure
R = Type 3R Enclosure D3 = Off Delay Timer Pump 3 T1 = 5-150 PSI, Bourdon Type
D = Type 3R Double Door Enc. E = Elapsed Time Meter for T2 = 10-200 PSI, Bourdon Type
T = Type 12 enclosure each Pump Running T3 = 10-300 PSI, Bourdon Type
W = Type 4 Stainless Steel F1 = Mounting Feet 12" T4 = 18-116 PSI Diaphragm Type
P = Type 4 Painted Steel H1 = Audible & Visible Alarm With T5 = 15-232 PSI Diaphragm Type
S = Type 4 Painted Steel Silencing Circuit - Signal T6 = 2-60 PSI, For Low Suction
With Double Door Source Separate Alarm

* Specify Contactor Size after modification


ie: S110=Pump 1 NEMA Size 1, S212 Pump 2 CL01

DS NE 20 R E 3 6 03 -T46 A D - 20/460
Contactor Sizes * 3 = 3 Phase Transformer and Voltage
05 = HP05 Starter 2 = Single Phase Code Suffix refer to
10 = HP10 Starter Page C9.
25 = HP25 Starter
30 = TM3 Starter 1 = 120 Volt Rating Horse Power / Voltage
40 = TM4 Starter 2 = 250 Volt Rating
6 = 600 Volt Rating
Fuse Clip Size Fuse Clip Size
Cover Controls
Fuse Clip Class R Fuse Clip
O = Internal O/L Reset Only 03 - 30 ampere 93 - 30 ampere
E = H-O-A Internal O/L Reset 06 - 60 ampere 96 - 60 ampere
B = H-O-A with External O/L Reset Class J Fuse Clip No number or
F = Start-Stop PB'S Internal O/L Reset 13 - 30 ampere 00 - no clips
1
6
C = Start-Stop PB'S W/External O/L Reset 16 - 60 ampere
6

Ordering Information
As standard all 3 phase controllers include transformer and H-O-A selector switch for each starter.
Select Catalog Number and Price for largest Motor HP size. If different HP sizes are required specify
with modification "S" to change starter size.
Pump Controllers include heaters for NEMA Starters
When ordering specify each motor full load amps, HP and Voltage for correct selection of motor overload protection.
Complete Cat. No. by including HP & Voltage at the end.

E4
Index Fire Pump Control
Description Page Number

General Information ............................................................... F2

Electric Motor Controller ......................................................... F3

Diesel Engine Controller ......................................................... F4

Alarm Panel ............................................................................ F5

Medium Voltage ..................................................................... F6


C

3
0
5

Visit our Website www.joslynclark.com for detailed information

F1
Fire Pump Controller For Electric Driven Fire Pumps

Standard Equipment & Performance


• Single handle operator for easy operation of isolating switch & circuit breaker
• Door interlocked with switch to prevent unintended exposure to electrical hazard
• Automatic start with Pressure Control, Display & Logging
• Complies with latest edition of NFPA 20

System Pressure Display


• Ten inch pressure Chart Recording accessible through outer door
• Programmable Pressure Units (psi, kPa, bars)
• Pressure Adjustable in Increments of 1psi
• Failsafe Design (motor runs on loss of control power)
• Built-in Running Period Timer and LED
• Standard Sequential Start Timer and LED
• Deluge valve start from normally closed contact (open to start)
• Remote start from normally open contact (close to start)
• Emergency start, by simply lifting the mechanical start handle

Operator interface:
• 2 line liquid crystal display of all 3 phase to phase RMS voltage and
F current measurements simultaneously
• Real time clock
• RS485 communications
• LED “Power Available”: (Green) Illuminates when all three phase voltage are
greater than 83% of nominal. Extinguishes if one or more phases are below 83%
of nominal. LED will flash for 5 seconds if a brownout condition is detected
• LED “Phases Reversed”: (Red) Illuminates if phases are reversed.
• LED “Locked Rotor Impending Trip”: (Red) Flashes on impending breaker trip
• Test function for motor locked rotor protection. Software test through keypad
combination, will cause Motor Locked Rotor LED to flash. After appropriate time
delay, shunt trip relay of the Motor Protector will energize.
• Test function for Phases Reversed. Software test through keypad combination to
test the phase detection circuit for five seconds.
• Data logging at time of motor start (auto or manual), Motor Stop, Power On and
Power Off
• Tamper proof Membrane keypad for setting clock and recalling data logging

Microprocessor Motor Protector:


• Locked Rotor over-current protection: - Non-adjustable trip set to NFPA 20 7-4.4
requirements
• Detects phase loss by voltage level (one or more phases below 17% of nominal for
more than 30 cycles, phase angle and voltage imbalance greater than 6% for more
than three seconds)
• “Brown-out” detection: one or more phases below 83% of nominal to signal front panel.
Typical scan time: 1 per 1/4 to 1/2 second
• Phase reversal detection
• Provides Static Single Phase Protection: Permits motor to run under dynamic single
phase condition
• Accuracy: Voltage 1%, Current 3% at normal motor running conditions

Visit our Website www.joslynclark.com for detailed information

F2
General Information Fire Pump Control
Motor Starting Types Automatic Transfer Switch Modification
Across-The-Line Type D10630 Fire Pump Controllers with Automatic Transfer Switches
The most economical and most commonly used type of fire provide for power connections to the fire pump motor from
pump controller. Full voltage is applied to the motor for the primary power source or an alternate power source.
srarting, by use of a single motor contactor. Starting inrush If the primary power fails, the transfer switch automati-
is approximately 600% of rated motor full-load amperes. cally switches to the emergency source. Automatic
retransfer to primary power source occurs after restora-
Autotransformer Type D10640 tion of normal power.
The motor circuit voltage is reduced by autotransformer The alternate source may be an emergency generator or
action during the motor starting period. A line contactor by- second utility supply. Circuit requirements differ for each
passes the autotransformer after a time delay. type, therefore the alternate source must be specified.
Starting line current is 42% of across-the-line starting
The Automatic Transfer Switch is housed in a barriered
inrush approximately 250% rated motor full-load amperes
compartment of the Fire Pump Controller. This complete
with the autotransformer on the 65% tap as shipped from
assembly, consisting of Fire Pump Controller and Auto-
the factory. A 50% and 80% tap can be used.
matic Transfer Switch is factory assembled, wired, tested
and shipped as a single unit.
Primary Resistor Type D10650
A resistor, inserted in the motor line, results in soft starting
and smooth acceleration. A line contactor by passes the
resistor after a time delay. Starting line current is 65-74% of
across-the-line starting inrush approximately 390-444% of
rated motor full-load amperes.
F
Part Winding Type D10670
2-winding type motor required - the first winding is con-
nected to the line to start; the second connected in parallel
by a second contactor, after a time delay. Starting line
current is 65% of across-the-line starting inrush - approxi-
mately 390% of rated motor full-load amperes.

Wye-Delta Type D10680 and D10690


Under a normal automatic start mode, the start contactors
close connecting the motor to the line in a wye connection.
After approximately 3 second time delay the start contactors
open and the run contactor closes reconnecting the motor
in a Delta connection.
Starting line current is 33.3% of across-the-line starting
inrush - approximately 200% rated motor full-load amperes.
Closed transition type D10680 provides no power interrup-
tion to the motor during transition from Wye to Delta connec-
tion, This provides smooth acceleration.
Open transition type D10690 provides on brief interruption
of power to the motor during transition from start to run.

Solid State Reduced Voltage Type D10620


Solid State reduced voltage fire pump controllers provide
smooth, stepless transition from initial voltage to full run
voltage. This results in soft starting with smooth acceleration
4
1
and deceleration. Starting line current may be adjusted
5 down to 200% of rated full-load amperes.

Visit our Website www.joslynclark.com for detailed information

F3
Fire Pump Control General Information
General
Joslyn Clark Diesel Fire Pump Controllers are designed
and listed specifically for diesel engine driven fire pump
service. These controllers meet or exceed all require-
ments of the National Fire Protection Association Standard
NFPA 20, are listed by Underwriters Laboratories Inc., and
approved by the Factory Mutual System.
The diesel controller provides four (4) major functions:
Starts the diesel engine automatically from water
pressure control or nonautomatically from manual
electric control.
Monitors engine as well as system conditions.
Maintains charge on engine starting batteries.
Initiates a weekly test of the system.

Standard Equipment
Type 2 Drip-Proof, Moisture Resistant, lockable
enclosure with break glass panel, is suitable for wall
or floor mounting. Painted with a UL Recognized
F Corrosion Resistant red baked enamel offers
superior resistance to the damp corrosive environ-
ment of pump rooms.
Voltage surge arrester for incoming 120 Volt AC
supply is connected to a line disconnect switch.
Provides an added degree of component pro-
tection against lightning strikes for greater reliability.
Visual indicators and audible alarms are provided to
indicate the following:
Automatic ON Charger Loss
Low Oil Pressure #1 Battery Overcharge
Engine Over Temp #1 Battery Failure
Safety Shut Down #2 Battery Overcharge
Fail To Start #2 Battery Failure
Engine Overspeed

2 SETS OF SPDT contacts for remote alarm of :


Engine Running, Engine Failure and Controller
Switch Off.
Battery chargers are solid state, 12 amps
current limiting for 225 ampere hour batteries.
Pressure recorder 7 day spring wound type is
located with the pressure switch below and away Safety shut down circuit will shut down engine on "Low
from electric components. Oil Pressure" and "Engine Over Temperature" if engine
is running due to "Weekly Test" or "AC Power failure".
Programable Weekly Timer to automatically start An alarm will signal this condition.
and run the engine for 30 minutes once a week.
Two "Manual Start" pushbuttons are provided to crank
Solid State crank cycle controller is a plug-in tamper from either battery or both at the same time for hard 3
resistant module. start conditions. 0
5
Internal plumbing and solenoid valve is rated for LED's (light emitting diodes) provide easy diognotics
500 PSI service. of engine and controller interaction as well as charger
and battery conditions.

Visit our Website www.joslynclark.com for detailed information

F4
General Information Fire Pump Control
Alarm Panel
General
Joslyn Clark alarm panels provide visual signals and
audible alarms to monitor the status and operation of the
pump controller. A separate, "reliable" source of 115V
supervisory power must be provided to the alarm panel.
Each abnormal condition lights the appropriate light and
sounds the audible alarm. The audible alarm can be push
button silenced, but the light remains lit until the abnormal-
ity is cleared. Signals are independent of each other and
the panel operation will repeat for each new abnormal
condition, regardless of the previous status.

Standard Equipment & Performance


Type 1 wall mounting enclosure
Key lockable enclosure
Alarm test button
Individual audible alarm silence button
Basic Type 10665-1 alarm panel includes both visual
and audible alarms for:
Supervisory power failure
Pump Running
Phase Reversal
Phase Loss and-or Controller power loss
F
Field Connection Diagram A10-357165
Schematic Diagram A10-357160

Listed Modifications
Fire Pump Start - This is commonly called "Remote
Start" for starting the main fire pump controller.
Up to three additional alarm lights and silence buttons
may be ordered. Specify name plate markings. Signal
contacts must close for alarm.

1 Thru 8 is a combination Pushbutton &Light.

1. Supervisory Power Failure


2. Pump Running
3. Phase Reversal
4. Phase Loss and/or Control Power Loss
5. Option 1 "Fire Pump Start" Button (Remote Start)
6. Option 4
7. Option 5
8. Option 2

3
0
5

Visit our Website www.joslynclark.com for detailed information

Ordering Information
See Price Sheet PS-10600-1

F5
General Information Fire Pump Control
Medium Voltage Type
General
Medium voltage fire pump controllers are primarily used to start large
horsepower motors. These starters are designed for automatic starting of
squirrel cage motors when starting current must be reduced.

Motors starting current at 2300 volts or 4160 volts is considerably below that
at 460 volts. This eliminates many problems that exists when starting large
horsepower motors at lower voltages.

Approvals and Standards


Joslyn Clark Controllers are UL listed and FM approved for applications up to
7200 volts. They are built to meet or exceed the following standards:

NEMA ICS2-329 class E2


UL 347 High Voltage Industrial Control Equipment
NFPA 20 The Installation of Electric Fire Pumps
NFPA 70 National Electrical Code

F Construction Details
Enclosures - Free standing, single high, non withdrawable starter
mounted in a NEMA 2 enclosure. NEMA 3R and 12 enclosures
are also available. NEMA 4 design includes an outer shell. The
enclosure is painted, all other parts are plated with corrosion
resistant materials. Type 4X outer enclosure is constructed with
#304 stainless steel.

Grounding - The control enclosure can be grounded through the


conduit connections and by ground wire to grounding pad.

Isolating Means - The isolating means is Fault Making, Load


Breaking, visible break disconnect switch externally operable.
The 3 blades are grounded in the open position. It has an
auxiliary contact that disconnects the control supply when
opened. It has a mechanical interlock so that the switch had to
be open before the high voltage door can be opened, and the
door has to be closed before the isolating switch can be closed.
The contactor is interlocked so that the isolating switch can not
be opened with contactor closed.

Power Fuse - Three medium voltage power fuses R-rated are


provided for short circuit protection.

Fuses - For Control Transformers - Three medium voltage control


transformers primary E-rated fuses are provided for short circuit
protection of control transformers.

Motor Starting - Manual electric starting may be obtained when


control circuit power is available by push button or by an
externally operable handle through a lever which actuates interlock
contacts. Manual electric starting causes the starting contactor coils
to be energized.

If control circuit power is not available, manual mechanical starting


may be obtained by the externally operable handle through a lever
which mechanically closes the motor run contact.
Visit our Website www.joslynclark.com for detailed information

F6
Index Mill Duty Products

Description Page Number

Limit Switches - Type 102HL .................................. G2


102TL ................................... G4
102RS .................................. G6
102CHL ................................ G7
102BST ................................ G8

Master Switch - Type 101FS .................................. G9


101SD .................................. G13
G
Palm Buttons - Type 100 RN ................................. G15

4
0
0

G1
Mill Duty Products Limit Switch
Right Hand Shown

Application
Type 102HL and HLD Hatchway Limit Switches are designed as
pilot circuit devices for all heavy duty applications to limit travel or
set up function at predetermined positions. OnType HL single
acting switches, the lever operates in one direction only; while on
Type HLD double acting switches, it operates in two directions with
a variety of contact sequences.

Features:
Double Break removable Silver-to-Silver Contacts.
Each contact may be independently changed from normally open
to normally closed and vice versa without disassembly.
Operating Arm on most models may be field changed to the other
side by reversing the shaft.
0
Lever Travel is 50 Oil impregnated bearings at contact finger pivot points.
Each Direction Oil impregnated shaft bearings need no lubrications.

Type HL Single Acting Hatchway - Limit Switch


2
Right Hand

Type Contacts Poles


Standard Enclosures
Catalog No. Price
1
Dust-tight Enclosure
Catalog No.
1
Watertight Enclosure
Price Catalog No. Price 1
G
HLA-1 NO or NC 1 A102-41252A-1 $ 402. A102-231414A-1 $ 474. A102-54634A-1 $ 582.
HLA-2 2 NO or 2 NC 2 A102-41251A-1 438. A102-231413A-1 510. A102-54635A-1 618.
HLA-3 1 NO & 1 NC 2 A102-41251A-3 582. A102-231413A-3 654. A102-54635A-3 768.
4
HLA-30 1 NO & 1 NC overlapping 2 A102-54268A-1 582. A102-273562A-1 654. A102-68866A-1 768.
2
Left Hand
HLLA-1 NO or NC 1 A102-41252A-3 402. A102-231414A-3 474. A102-54634A-3 582.
HLLA-2 2 NO or 2 NC 2 A102-41251A-4 438. A102-231413A-4 510. A102-54635A-4 618.
HLLA-3 1 NO & 1 NC 2 A102-41251A-6 582. A102-231413A-6 654. A102-54635A-6 768.
4
HLLA-30 1 NO & 1 NC overlapping 2 A102-54268A-2 582. A102-273562A-2 654. A102-68866A-2 768.

Any 1 or 2 pole switch may be converted from right to left hand


and vice versa using a screwdriver. Limit Switch Electrical Ratings
Note: 25 Amp - 600V AC Maximum
1. Price includes operating lever and standard steel roller. Heavy Pilot Duty 600V AC A600, 250V DC Maximum N300.
2. Type HLA-1, 2 & 44, HLLA-1 & 2 contacts are normally closed when
Current - Amperes
shipped from the factory. To change
to normally open, loosen cam and rotate 1800. Volts Carry Break Inrush/ Make
3. Any 1 or 2 pole switch may be converted from right to left hand and 110-120V AC 25 6.0 6.0
vice versa using a screwdriver. 220-240V AC 25 3.0 3.0
4. Overlapping contacts are not convertible. 440-480V AC 25 1.5 1.5
550-600V AC 25 1.2 1.2
115-125V DC 10 2.2 2.2 4
230-250V DC 10 1.1 1.1 8
5

Ordering Information
Use complete catalog number when ordering. If modification is required, state in full detail on the order.
Modifications:
Omit standard lever and roller, . . . . Deduct $ 24.
Phenolic composition roller, 21/2" dia., on standard lever in place of standard steel roller, A102-426105A . . . .Add $ 30.
Five-inch lever with standard steel roller, in place of standard lever and roller, A102-248096A . . . Add $ 162.
Seven-inch dia., composition roller on 5" lever, in place of standard lever and roller, A102-75993A . . .Add $ 294.

G2 Discount Schedule JC32


Limit Switch Mill Duty Products
Type HLD - Double Acting Hatchway - Limit Switch HLA-1, 2, 3 & 30, HLLA-1, 2, 3 & 30,
Standard and Dust-tight Enclosures
Contacts Sequence3 Standard Enclosure Dust-tight Enclosure Ship. 120 min. to operate std. 1 & 2 pole switches.
2
Poles CCW CW Catalog No. Price 1 Catalog No. Price 1 Weight Switches with overlapping contacts require 220 min.
1 HLD-1 $ 660. HLD-5 $ 726.

2 HLD-2 738. HLD-6 804.


11 lbs.
2 HLD-3 738. HLD-7 804.

2 as specified HLD-4 780. HLD-8 846.


Contacts Sequence Watertight Enclosure Ship.
Poles CCW CW Catalog No. Price Weight

1 HLD-9 $ 858.

2 HLD-10 936.
12 lbs.
2 HLD-11 936.

2 as specified HLD-12 978.

G
Cams are $38.00 each and included under JC80
HLD-1, 2, 3 & 4 in Standard Enclosure
Contact Sequence HLD-5, 6, 7 & 8 in Dust-tight Enclosure
Cam No. As Supplied Converted To: Spare Parts JC 80
CCW CW CCW CW Movable Contact A101-028965 $26.00
Torsen Spring A101-062988 $25.00
A102-277623 1 Pole Base A102-041256A $90.00
A102-277624 2 Pole Base A102-041255A $156.00
A102-277625 Std. Arm & Roller A102-302350A $122.00
5" Lever with JC32
Contact Closed Contact Open Steel Roller A102-248096A $270.00

5" Lever with


CCW CW
Top
CW Right Hand 7" Dia. Compo-
Right Side sition Roller A102-075993A 402.00
View Operation
CCW View

Limit Switch Electrical Ratings


25 Amp - 600V AC Maximum
Heavy Pilot Duty 600V AC A600, 250V DC Maximum N300.
Current - Amperes
Volts Carry Break Inrush/ Make
110-120V AC 25 6.0 6.0
0 220-240V AC 25 3.0 3.0 Notes:
3
3
440-480V AC 25 1.5 1.5 1. Price includes operating lever and standard steel roller.
550-600V AC 25 1.2 1.2 2. All contacts are NC when shipped from the factory. To change to
115-125V DC 10 2.2 2.2 NO, loosen cam and rotate 1800.
230-250V DC 10 1.1 1.1 3. Any 1 or 2 pole switches may be converted from right to left hand
and vice versa, using a screwdriver.

Ordering Information
Use complete catalog number when ordering.
Modifications on page G2. If modifications are required, state in full detail on the order.

Discount Schedule JC32 G3


Mill Duty Products Limit Switch
Application
Type 102TL Track Type Limit Switches are designed as pilot circuit
devices for all heavy duty applications to limit travel or set up functions
at predetermined positions.

Operation
The contacts of these switches make and break very quickly due to the
snap action of the toggle type operating mechanism. The operating arm
is secured to a hollow outer shaft that fits over the camshaft. When the
arm is tripped, it turns the outer shaft which actuates the toggle
mechanism. The toggle mechanism does not change position until the
operating lever is past the midpoint of its travel; then it snaps over and
turns the camshaft quickly. Since the cams are fastened rigidly to the
camshaft, they in turn impart snap action opening and closing to the
contacts. Force to operate switch is approximately 25 inch-pounds.

Angular Travel
Total angular travel of the arm from one tripped position to the other is
900. However, the contacts are actuated when the arm moves 600, the
balance of the travel is to clear the arm so that the linear operator may
pass over.
Features:
TLSF-11 or 22 with Straight Fork Lever
Double Break removable Silver-to-Silver Contacts.
Each contact may be independently changed from normally open
to normally closed and vice versa without disassembly.
enclosures are also available for all types.
Contact wearing parts completely interchangeable with
G
Operating Arm adjustable on shaft. same parts in Type 101SD Master Switch, 101FS Foot
Oil impregnated bearings at contact finger pivot points. Switch, and 102HL & CHL Limit Switch.
Cast weatherproof enclosure standard. Dust-tight and watertight

Available Levers:

Left Hand Shown:

Part # A102-054262
TLSF Straight
Fork Lever
Part # A102-054261
TLS Rod or
Chain Type Lever

0
3
3

Part # 102-54260A $366


A102-460805A-1 $214 TLF Roller Fork
TLSR Straight Roller Lever Lever TLF-22, 2 Contacts, Cover Removed

G4
Limit Switch Mill Duty Products
Type TL Snap Action - Limit Switch
Standard Enclosure Dust-tight Enclosure Watertight Enclosure
2 1 1 1
Type Operating Lever Contacts Catalog No. Price Catalog No. Price Catalog No. Price
TLS-11 Rod or Chain 1 A102-80579A-1 A102-80579A-2 A102-80580A
TLS-22 Rod or Chain 2 A102-80581A-1 A102-80581A-2 A102-80582A
TLSR-11 Straight or Roller 1 A102-80591A-1 $ 846. A102-80591A-2 $ 918. A102-80592A $ 1746.
TLSR-22 Straight or Roller 2 A102-80593A-1 A102-80593A-2 A102-80594A
TLF-11 Roller Fork 1 A102-80575A-1 A102-80575A-2 A102-80576A
TLF-22 Roller Fork 2 A102-80577A-1 A102-80577A-2 A102-80578A
TLSF-11 Straight Fork 1 A102-80583A-1 900. A102-80583A-2 972. A102-80584A 1824.
TLSF-22 Straight Fork 2 A102-80585A-1 A102-80585A-2 A102-80586A

Limit Switch Electrical Ratings


Note: 25 Amp - 600V AC Maximum
1. Price includes limit switch complete with operating lever. Heavy Pilot Duty 600V AC A600, 250V DC Maximum N300.
2. Contacts can be changed from open to close by rotating cam 1800. Current - Amperes
Volts Carry Break Inrush/ Make
Ordering Information:
Use complete catalog number when ordering. 110-120V AC 25 6.0 6.0
220-240V AC 25 3.0 3.0
440-480V AC 25 1.5 1.5
550-600V AC 25 1.2 1.2
115-125V DC 10 2.2 2.2
230-250V DC 10 1.1 1.1
Approximate Outline Dimensions G
TLS Rod or Chain Type Lever
TLSR Straight Roller Lever

Enclosure Dimensions Only


(Same for all types)

TLSF Straight Fork Lever TLF Roller Fork Lever

0
3
3

Discount Schedule JC32 G5


Mill Duty Products Safety Switches

Application
Type 102RS Rubber Calender Safety Switch is a pilot circuit
device used chiefly in the Rubber Industry as an emergency stop
arrangement on Calenders, and similar motor driven machinery.

Features:
Gravity Operated.
Double break removable silver-to-silver contacts.
Can be mounted horizontally or vertically.
Oil impregnated shaft bearings need no lubrication.
Contact wearing parts completely interchangeable with same
parts in type 101SD Master Switches, type 101FS Foot Switches
and type 102HL, CHL, TL Limit Switches.
Dust-tight enclosure is standard.

Limit Switch Electrical Ratings


25 Amp - 600V AC Maximum
Heavy Pilot Duty 600V AC A600, 250V DC Maximum N300. G
Current - Amperes
Volts Carry Break Inrush/ Make
Approximate Dimensions
110-120V AC 25 6.0 6.0
220-240V AC 25 3.0 3.0
440-480V AC 25 1.5 1.5
550-600V AC 25 1.2 1.2
115-125V DC 10 2.2 2.2
230-250V DC 10 1.1 1.1

Rubber Calender
Dust-tight Enclosure
Type Contacts Poles Catalog No. Price 1
RS22 2 NC 2 A102-66750A $ 1224.
0
3
Note: 3

1. Price includes limit switch complete with cable, cable


Ordering Information weight and counterweight.
Use complete catalog number when ordering. If modification is required, state
in full detail on the order.
Modifications:
If cradle bar tripping arrangement is desired, add the following to the catalog
number, "including part number A102-66747A tripping bar" . . . . . .Add $ 72.

G6 Discount Schedule JC32


Limit Switch Mill Duty Products
Application
The Type 102CHL pilot circuit limit switches are designed for
mounting beneath the hoisting mechanism of electrically oper-
ated cranes to serve as upper limit safety stop switches. Such
a safety device is neccessary to prevent the hook from being
raised into the hoisting mechanism where it would cause
damage.

Enclosure - Standard die cast aluminum enclosures.


1
Dust-tight Enclosures - Dust-tight enclosures can be fur-
nished at an additional charge for the dust seal gasket.

Watertight - Watertight enclosures are also available. The


2
same heavy case is specially fitted with watertight bushings Cams A102A52609 for $38
and seals to meet NEMA watertight tests. 2 Pole Base A102A41255A $179
Weight 1 B102-80615 $411
Weight 2 A102-54265 $340
Features:
Toggle type snap action. Each contact may be independently changed from N.O. to N.C. and
Double break removable Siver-to-Silver Contacts. vice versa without disassembly, by turning cams on shaft 1800.
Contact wearing parts completely interchangeable with Operating arm adjustable on shaft.
same parts inType 101SD Master Switch, Type 101FS Automatic reset when hook is lowered.
Foot Switches and Type 102HL and TL Limit Switches. Die cast aluminum enclosure standard.
G
Type 102CHL Crane Hook - Limit Switch
Standard Enclosure Watertight Enclosure
Type Contacts Poles Catalog No. Price 1 Catalog No. Price1
CHL-22 2 NC 2 A102-80886A $ 1392. A102-80887A $2256.

Approximate Dimensions

Limit Switch Electrical Ratings


25 Amp - 600V AC Maximum
Heavy Pilot Duty 600V AC A600, 250V DC Maximum N300.
Current - Amperes
Volts Carry Break Inrush/ Make
110-120V AC 25 6.0 6.0
220-240V AC 25 3.0 3.0
440-480V AC 25 1.5 1.5
550-600V AC 25 1.2 1.2
115-125V DC 10 2.2 2.2
230-250V DC 10 1.1 1.1

0
3
3 Note:
1. Price includes limit switch complete with cable, cable weight and
counterweight. Approximate shipping weight is 45 lbs.

Ordering Information
Use complete catalog number.
If dust-tight enclosure is desired, add $66 to the standard enclosure price. Use the same catalog number as for standard enclosure and
specify "Dust-tight" on the order.

Discount Schedule JC32 G7


Mill Duty Products Limit Switch

Application
The Type 102BST Switch is a pilot device used for special protection
against side movement of conveyor belts.

Operation
One Switch is mounted on each side of the conveyor belt with the lever
mounted roller close to the belt edge. If the belt tends to move either side
due to misalignment of its rollers, the belt edge moves the limit switch
lever arm. After a selected number of degrees of lever
movement the normally open contact in the switch closes. This can
operate a warning system, either a light or audio signal. If the fault is not
corrected and the belt moves the lever arm to large degree, a second
contact, normally closed, will open and shut down the system. The type
BST switch can save untold down time and expense in torn and
damaged conveyor belts. Also when used in conjunction with the Type
RS Safety Limit Switch, they form a team of safety devices that provide
protection to both the operators and belts. The Type BST
Switch uses a NEMA Type 4 Watertight enclosure. The Type BST-22
has an 8" Stainless Steel Roller with Nylon Bushings, mounted on a
lever arm so that the middle of the roller has a 9 3/8" radius.

G
Type 102BST Belt Side Travel - Limit Switch
Shaft Dust tight Enclosure
1
Type Contacts Type Operator Type Catalog No. Price
8" long stainless
BST-22-R 2 Stan- steel roller with A102-351409A-1 $ 1392.
dard nylon bushing

Note:
1. One normally open and one normally closed overlapping contacts.
Lever only A102-463807A $ 820 x JC80

Approximate Dimensions

3
8
0

G8 Discount Schedule JC32


General Information Mill Duty Products
Application Enclosures
Type 101 FS Foot Operated Master Switches are used Two pole foot switches have cast aluminum enclosures.
on applications requiring a rugged foot operated pilot
circuit device. Watertight enclosures are available for all types except
Type FWLSA-22. The same heavy case is specially fitted
Weatherproof enclosures are standard on all types. with watertight bushings and seals to meet NEMA water-
tight tests.
Dust tight enclosures can be furnished at an additional
charge for the dust seal gasket.

Features
Double Break removable Silver-to-Silver Contacts. Oil impregnated bearings at contact finger pivot points.
Contact wearing parts completely interchangable Oil impregnated shaft bearings need no lubrications
with the same parts in Type 101SD Master Switch, Mallable iron operating pedal.
and Type 102HL, TL and CHL Limit Switch. Spring return standard.
Each contact may be independently changed from Cast Weatherproof enclosure standard.
NO to NC and vice versa without disassembly.

FSVA-11, 22 or 33, 1 or 2 FSLA-11, 22 or 33, 1 or 2


Pole with Latch, Vertical Pole with Latch, Horizontal
Mounting Mounting

FSA-44, 4 pole FRSA-22, 2 Pole 3 Position

3
8
0

FWSA-22, 2 Pole FWLSA-22, 2 Pole, Sequence FSA-22, 2 Pole


Sequence Operation Operation with Latch Horizontal Mounting, Left Hand, Open View

G9
Mill Duty Products Master Switch

Type 101FS - Foot Operated Standard NEMA 1 Enclosure


2
Contact Mounting Pedal Dim. Ref &
1
Type Poles Contact Arrangement Symbol Special Features Arrangement Arrange- Catalog No. Price Ship Weight
ment
FSA-11 1 NO or NC A or B ---------- A101-55171A-2 $ 654.
FSA-22 2 Both NO or NC C or D ---------- A101-55172A-2 738.
FSA-33 2 1 NO & 1 NC E ---------- A101-55172A-2 738. 1&2
FSA-330 2 1 NO & 1 NC F Overlapping Horizontal or R.H. or L.H. A101-46250A (3)
Overlapping Vertical
FSLA-11 1 NO or NC A or B A101-55173A 690.
FSLA-22 2 Both NO or NC C or D A101-55174A 768. 1
FSLA-33 2 1 NO & 1 NC E A101-55174A 768.
FSVA-11 1 NO or NC A or B With latch A101-55175A 768.
FSVA-22 2 Both NO or NC C or D Vertical Only R.H. or L.H. A101-55176A 846. 2
FSVA-33 2 1 NO & 1 NC E A101-55176A 846.
FSA-22S 2 2 NO or 2 NC - ---
Sequence operation Contacts operate Horizontal or R.H. or L.H. A101-46250A 738 1&2
FSA-33S 2 1 NO or 1 NC - --- in Sequence Vertical
Sequence operation
Double treadle foot
FRSA-22 2 1 forward, 1 reverse
and an off point --- pedal for reverse
Horizontal
Only
R.H. or L.H. A101-62266A 900. 3
G
operating

Contact Symbols

A B C D E F

Note:
1. Price includes switch complete with operating pedal.
2. Page G12 for Dimension reference and shipping weight.
3. Overlapping Contacts:
Standard switches provide for only one contact closed at a time. If overlapping is required, one contact must close before the other contact
opens. Type FSA-330 switches have overlapping contacts. If the degree and/or point of overlap is not specified, price in quantities of 1 or more
0
is $ 738. If purchaser specifies degree and/or point of overlap: Price in quantities of 5 or less is $900.00. Price in quantities of 6 or more is 3
$738. 3

Ordering Information Modifications Price


Use complete catalog number when ordering. If modifications are For Dust tight use same catalog number as for a $ 84.
required, state in full detail on the order. standard enclosure and specify "Dust tight" on order.
Note: Floor plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.
Type 101FS does not meet the safety standards for press applications.

G10 Discount Schedule JC32


Master Switch Mill Duty Products

Type 101FS - Foot Operated NEMA 4 Enclosure


2
Contact Mounting Pedal Dim. Ref &
1
Type Poles Contact Arrangement Symbol Special Features Arrangement Arrange- Catalog No. Price Ship Weight
ment
FSA-11 1 NO or NC A or B ---------- A101-60224A $ 846.
FSA-22 2 Both NO or NC C or D ---------- R.H. only A101-60225A 924.
FSA-33 2 1 NO & 1 NC E ---------- Horizontal or A101-60225A 924. 1&2
FSA-11 1 NO or NC A or B ---------- Vertical A101-60226A 846.
FSA-22 2 Both NO or NC C or D ---------- L.H. only A101-60227A 924.
FSA-33 2 1 NO & 1 NO E ---------- A101-60227A 924.
FSLA-11 1 NO or NC A or B A101-60228A 900.
FSLA-22 2 Both NO or NC C or D R.H. only A101-60229A 978.
FSLA-33 2 1 NO & 1 NC E Horizontal A101-60229A 978. 1
FSLA-11 1 NO or NC A or B Only A101-60230A 900.
FSLA-22 2 Both NO or NC C or D With Latch L.H. only A101-60231A 978.
FSLA-33 2 1 NO & 1 NC E A101-60231A 978.
FSVA-11 1 NO or NC A or B A101-62868A 978.
FSVA-22 2 Both NO or NC C or D Vertical Only R.H. only A101-77635A 1056. 2
FSVA-33 2 1 NO & 1 NC E A101-77635A 1056.

FRSA-22 2 1 forward, 1 reverse --- Double treadle foot Horizontal R.H. or L.H. A101-62267A 1110. 3
and an off point pedal for reverse
operating
Only G

Contact Symbols

A B C D E F

Notes:
0 1. Price includes switch complete with operating pedal.
3
2. Page G12 for Dimension reference and shipping weight.
3

Ordering Information Modifications Price


Use complete catalog number when ordering. If modifications are For Dust tight use same catalog number as for a $ 84.
required, state in full detail on the order. standard enclosure and specify "Dust tight" on order.
Note: Floor plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.
Type 101FS does not meet the safety standards for press applications.

Discount Schedule JC32 G11


Mill Duty Products Master Switch

Dimensional Information
Reference No. 1 - Horizontal

Shipping Weight (approx.)

Reference Weight
No. 1 12 lbs.
No. 2 12 lbs.
No. 3 15lbs.

Reference No. 2 - Vertical Reference No. 3- Double Treadle

3
8
0

G12
Master Switch Mill Duty Products

Type 101SD Master Switches are designed as pilot circuit devices for
frequent operation with minimum maintance on heavy duty application in all
industries. The type SD units are sturdy devices constructed for heavy duty
service where few control circuits are required. Type SD Switches are made
in two frame sizes:

Type SD-2 is a single point device, one point either side of the off point, and
there are two isolated contacts which can be opened or closed in various
combinations.

For the usual circuit arrangements refer to page G14.

Type SD Master Switches are supplied in watertight enclosures; panel mounted


units have angle brackets for back of panel mounting. Spring return to the off
point is available.

Master Switch, Enclosed Type SD-2 Two Circuit

G
Mill Master Jr. - Master Switch
Standard Operation
Number of No. of Surface Mounting Dim. Panel Mounting Dim.
1 2
Type Operating Points Cir- Reversing Catalog No. Price Ref. Catalog No. Price Ref.
cuits
1 (each direction) yes A101-88359A A101-88360A
SD-2 2 $ 798. A $ 1272. C
1 (one direction only) no A101-88363A A101-88364A
Spring Return Operation
1 (each direction) yes A101-88361A A101-88362A
SD-2-S 2 1080. A 1512. C
1 (one direction only) no A101-88365A A101-88366A

Notes:
1. Price includes master switch in watertight enclosure complete with operating handle.
2. Price includes master switch in watertight enclosure complete with metal pistol grip handle, steel
mounting plate and standard anualar name plate. Specify nameplate markings; standard nameplate
provides one marking for each point of the switch.
Advise detailed cam development for each switch. Refer to page G14 for diagram of standard cam
development.

Ordering Information:
Use complete catalog number when ordering.
3 Dimensional reference on page G14
8
0

Discount Schedule JC32 G13


Mill Duty Products Master Switch
Shipping Weight (approx.)
Reference Weight
A&C 10 lbs.

Spring Return
A&C 15 lbs.
Dimensional Information

Reference A - Surface Mounting

Reference C - Back of Panel Mounting

Standard Contact Sequence Diagrams

ON ON REV. FOR.

Off 1 Off 1 1 Off 1

1 1 1

2 2 2

Figure 1 Figure 2 Figure 3


Type SD-2 Type SD-2 Type SD-2
Type SD-2-S Type SD-2-S Type SD-2-S

3
8
0

G14
100 Series
Mill Type Push Buttons (Heavy Duty)
Type H Assembled

Features:
Heavy cast enclosure and mushroom operating head.
Oil impregnated bushing.
Heavy duty Type H push button element with double break
silver-to-silver wipe action contacts.
Large electrical clearance.
Push button stop independent of contacts. All shock ab-
sorbed by the cast case.
All parts removable and replaceable with a screwdriver. Type H Form RN Type H Form RNG
Unprotected With Guard Ring for
Palm Operation
Type H - Momentary Contact
Form RN - Without Guard Ring Form RNG - With Guard Ring
2
Name Plate Contacts Contact Catalog Catalog
Symbol Number Price 1 Number Price 1
Marking Available
None 1 N.O. and 1 N.C. 1 1RN-1 $ 258. 1RNG-1 $ 258.
None 2 N.O. and 2 N.C. 4 1RN-2 300. 1RNG-2 300.
Start 1 N.O. and 1 N.C. 1 1RN-3 258. 1RNG-3 258.
Stop 1 N.O. and 1 N.C. 1 1RN-4 258. 1RNG-4 258.
Emer Stop
On
1 N.O. and 1 N.C.
1 N.O. and 1 N.C.
1
1
1RN-5
1RN-6
258.
258.
1RNG-5
1RNG-6
258.
258.
G
Off 1 N.O. and 1 N.C. 1 1RN-7 258. 1RNG-7 258.
Forward 1 N.O. and 1 N.C. 1 1RN-8 258. 1RNG-8 258.
Reverse 1 N.O. and 1 N.C. 1 1RN-9 258. 1RNG-9 258.
Jog 1 N.O. and 1 N.C. 1 1RN-10 258. 1RNG-10 258.
Jog Forward 1 N.O. and 1 N.C. 1 1RN-11 258. 1RNG-11 258.
Jog Reverse 1 N.O. and 1 N.C. 1 1RN-12 258. 1RNG-12 258.
Reset 1 N.O. and 1 N.C. 1 1RN-13 258. 1RNG-13 258.
Run 1 N.O. and 1 N.C. 1 1RN-14 258. 1RNG-14 258.
Slow 1 N.O. and 1 N.C. 1 1RN-15 258. 1RNG-15 258.
Fast 1 N.O. and 1 N.C. 1 1RN-16 258. 1RNG-16 258.
Up 1 N.O. and 1 N.C. 1 1RN-17 258. 1RNG-17 258.
Down 1 N.O. and 1 N.C 1 1RN-18 258. 1RNG-18 258.
Start 2 N.O. and 2 N.C. 4 1RN-19 300. 1RNG-19 300.
Stop 2 N.O. and 2 N.C. 4 1RN-20 300. 1RNG-20 300.
Emer Stop 2 N.O. and 2 N.C. 4 1RN-21 300. 1RNG-21 300.
Note:
1. Price includes assembled push button station complete with element Contact Blocks
and nameplate as designated. INO & INC BA $ 62.00 JC80
2. With Name Plate at top, case may be turned so that Conduit 2NO & 2NC BB $104.00 Discount
Opening is at top or bottom. Schedule

Maximum Contact Ratings (Per Pole)


AC (50 or 60 Hz) DC (Inductive) Dimensions
Volts Normal Inrush Normal
4 110-120 6.0 60 2.2
8 220-240 3.0 30 1.1
5 440-480 1.5 15 ----
550-600 1.2 12 0.4

Contact Symbols

Form RN Form RNG


Unprotected With Guard Ring for
1 4
Palm Operation

Discount Schedule JC31 G15


Definite Purpose Control Index

Description Page Number

General Application and Features ........................................... H2

2 Pole AC Contactors - Type DP2 ........................................... H3

2, 3 and 4 Pole Contactors - Type DP3 and DP5 .................... H3

Two 3 Pole Contactors Mechanically and Electrically


Interlocked - Type DP33 .......................................................... H4

Modifications and Parts .......................................................... H5

Engineering Data .................................................................... H6


H

4
1
0

H1
DP - Definite Purpose Control AC Contactors

H
Application Low Coil Inrush and Sealed VA Interchangeable
Definite Purpose Contactors are Provides maximum efficiency, Along with being compact in size,
intended for use in applications where permitting potential cost savings on the mounting plate is designed to
the control requirements are well transformer requirements. This facilitate proper alignment and
defined. They are not recommended efficient magnet system assures interchangeability with practically all
for general industrial use. clean pick-up and drop-out without competitive 2 pole contactors. Also,
As a magnetic motor controller, they chattering when subjected to slowly the low v-a permits direct inter-
are inductively rated for both rising and slowly decreasing voltages. changeability without requiring a
maximum continuous current and transformer change.
maximum locked rotor current Versatile Operating Positions Terminals
Resistive ratings apply to resistive Joslyn Clark 2 pole contactors are As an optional feature, Joslyn Clark
heating applications only. designed to operate effectively in the contactors can be supplied with
Joslyn Clark definite purpose vertical, horizontial or tabletop pressure clamp terminals which are
contactors have been specifically mounting positions. This gives design UL Recognized for field connec-
designed for use with air conditioning, engineers maximum versatility for tions of #14 through #8 copper
heating and refrigeration control designing low cost systems. wire. They may also be supplied
equipment. They are suitable for other with box lugs for #4 through #14 Al/
non cycling duty applications requiring Cu wire.
reliable low cost switching. Up To 600 Volts A-C Rating
The 2 pole contactors have been
designed with the customer in
4
mind. They provide clearance 1
between terminals permitting total 0
utilization of all quick connects
without requiring special insulation
between terminals on equipment
rated up to 600 volts.

H2
DP - Definite Purpose Control AC Contactors
2 Pole Contactors - Type DP2
20, 25 and 30 Ampere (Discount Schedule JC54)
Amp. Ratings
Type FLA Res LRA Volts Model Number Catalog Number Price
20 30 100 240/277
10 25 50 480 DP2C202- * A77-306680A- * $ 31.00.
10 25 50 600
25 30 125 240/277
10 25 50 480 DP2C252- * A77-306658A- * 39.00.
10 25 50 600
DP2
25 35 150 240/277
1 1
21 35 125 480 DP2HC252- * A77-306660A- * 41.00
17 35 100 600
30 40 150 240/277
1 1
15 40 75 480 DP2C302- * A77-306657A- * 43.00
12.5 40 60 600

---- 50 ---- 600 DP2HC302- * A77-306657A-5 * 46.00.

2, 3 & 4 Pole Contactors - Type DP3


25, 30 & 40 Amp. (Discount Schedule JC54)
Amp. Rating Locked Rotor Amps.
Type Poles
FLA Res 240V 480V 600V Model Number Catalog Number Price
2 DP3C252- * A77-309039A- * 49.00.
25 30 150 125 100 3 DP3C253- * A77-309040A- * 52.00.
4 DP3C254- * A77-309026A- * 67.00.
2 DP3HC252- * A77-309041A- * 52.00. H
25 35 150 125 100
3 DP3HC253- * A77-309042A- * 56.00.
2 DP3C302- * A77-309043A- * 56.00.
DP3 30 40 180 150 120 3 DP3C303- * A77-309044A- * 61.00.
4 DP3C304- * A77-309027A- * 76.00.
- - - -
50 3 DP3HC303- * A77-309044A-15- * 68.00.
1 1 68.00.
2 DP3C402- * A77-309045A- *
50 3 DP3C403- 1* A77-309046A- 1 * 76.00.
40 240 200 160
1
4 DP3C404- A77-309028A- 1 92.00
1 1
50 3 DP3LC503- * A77-309046A-15* 90.00

2 & 3 Pole Contactors - Type DP5


50 and 60 Amp. (Discount Schedule JC50)
Amp. Rating Locked Rotor Amps.
Type Poles
FLA Res 240V 480V 600V Model Number Catalog Number Price
2 DP5C502- * DP5C502- * 259.
50 65 300 250 200
DP5 3 DP5C503- * DP5C503- * 284.
4
2 DP5C602- * DP5C602- * 288. 4
60 75 360 300 240
3 DP5C603- * DP5C603- * 320. 5

Ordering Information Coil Table


Use complete catalog number. Replace the Engineering Data- Page H6 50/ 60Hz Model No. Cat.No.Suffix
(*) with a suffix from the Coil Table. Modification Data- Page H5 Voltage Suffix DP3 DP2 DP5
120 -120 1 1 120.
Example: 208-240 -240 2 2 240.
DP3C303-24 (A77-309044A-3) is a 3 pole Note: 24 -24 3 3 24.
30 ampere, contactor with a 24 Volt, 1- comes with cover 277 -277 Factory Factory 277.
50/60 Hz Coil. 480 -480 Factory Factory 480.

Discount Schedule JC50 & 54 H3


AC Contactors Definite Purpose Control - DP

Reversing Contactors - Mechanically & Electrically Interlocked Type DP33 - Bulletin 7735
25, 30 & 40 Amp.
Current Ratings Maximum 3 Phase Horsepower Ratings
No. of
Type
Amp. Rating Locked Rotor Amps. General Duty Jogging Duty
Aux. H
Ind. Res. 240V 480V 600V 200V 240V 460/575V 200V 240V 460/575V Model No. Catalog No. Contacts Price
2 $421.00
25 30 150 125 100 5 7 1/2 15 3 3 7 1/2 DP33C253- * A77-350735A- *
4 494.00
DP33 5 5 2 470.00
30 40 180 150 120 7 1/2 10 15 7 1/2 DP33C303- * A77-350737A- *
4 543.00
10 10 5 7 1/2 2 527.00
40 50 240 200 160 25 15 DP33C403- * A77-352100A- *
4 599.00

Mechanically and electrically interlocked contactors for low cost


motor reversing applications such as hoists, doors, gates, etc.. Use jogging duty rating on full-voltage magnetic controllers for
Standard assembly includes mechanical interlock with two plug-stop, plug-reverse and jogging duty regarding repeated
SPDT auxiliary contacts for electrical interlocking. interruption of stalled motor current or repeated closing of
Four additional auxiliary contacts may be factory added. Two high transient currents encountered in rapid motor reversal
may be field added. beyond five openings or closings per minute or more than ten
in a ten minute period.

Approvals
Underwriters Laboratories, Inc. recognized component Canadian Standards Associations (CSA) Guide
for air conditioning, refrigeration and resistance 361-E-0.2 Class 1222 File 18156-55
heating equipment. File number E6591, Section 27.
Guide number NLDX2.
4
2
2 Ordering Information Coil Table
Use complete catalog number. Replace Engineering Data Page H6. Model No. Cat. No.
the (*) with the suffix from the coil table. Modification Page H5. 50/60Hz Voltage 2 Aux. 4 Aux 2 Aux. 4 Aux.
120 120 120CC 1 4
208-240 240 240CC 2 5
Example: DP33C253-120 (A77-350735A-
24 24 24CC 3 6
1) is a 3 Phase, 25 amp., reversing 480 480 480CC
contactor with120V, 50/60 HZ coil and
SPDT auxiliary.

H4 Discount Schedule JC52


Modifications and Parts Definite Purpose Contactors-DP

Types DP2, DP3, DP5, DP, DP33, and DP3S Accessories & Parts Kits Discount Schedule JC50 2
Type DP2 Type DP3, DP33 Type DP5
20, 25 & 30 Ampere 25, 30, & 40 Ampere 50 & 60 Ampere
Descrip- Catalog
Catalog Catalog
tion Number Price Number Price Number Price
SPDT Auxiliary Contact Kit ---- ----
KHP-C 2 $ 39.00
N.O. Auxiliary Contact Kit ---- KDP5-10 $41.00
---- ---
N.O. & N.C. Auxiliary Contact ---- KDP5-11 61.00
Kit ----
Contact Cover A77-356577A-1 $ 4.00 A77-356577A-2 4.00
----
Pressure (Box) Lug Kit A77-352648A 7.00 A77-352648A 7.00
(Contains 3 Lugs)

Replacement Coil Kits Discount Schedule JC53


Type DP3, DP33 Type DP5
25, 30 & 40 Ampere 50 & 60 Ampere
Description
Catalog Catalog
Number Price Number Price

120V, 50/60Hz KTB170-1 $ 48.00 CDP5-120 $ 97.00


208-240V, 50/60Hz KTB170-2 48.00 CDP5-240 97.00
24V, 50/60Hz KTB170-3 48.00 CDP5-24 97.00
277V, 50/60Hz KTB170-4 48.00 CDP5-277 97.00
480V, 50/60Hz
600V, 60Hz
KTB170-5
KTB170-6
48.00
48.00
CDP5-480
CDP5-600
97.00
97.00
H

1
Field Modifications
Cat. No. Price Discount Schedule

Type 1 Enclosure Kit P6E-01 $80. JC14

Notes:
1. Additional modifications may be selected from NEMA HP Section C page C7
2. JC12 Discount Schedule for KHP-C.

Discount Schedule JC52 H5


DP-Definite Purpose Control Engineering Data
2 Pole Contactors, Type DP2 Dimensions (Approximate)
Coil Max. Max. D-C
Volts Inrush Sealed Pick-up Resistance
50/60Hz VA VA Volts Ohms
24 31 7 18 11
120 31 7 90 290
208-240 31 7 176 1173
Coil insulation - Class B
Coil connections - Double male 1/4" quick connect
Maximum ambient - 155oF

3 & 4 Pole Contactors - Type DP3 Dimensions (Approximate)


Coil D-C
Volts Inrush Sealed Pick-up Resistance
50/60Hz VA VA Volts Ohms
24 48 8.4 16 6.5
120 48 8.4 80 170
208-240 48 8.4 160 680

3 Pole Contactor - Type DP5 Dimensions (Approximate)

.37 2.63 .37


Coil Characteristics
Inrush VA 204
Sealed VA 36.5

3.13
3.75
3.25

4
1.5 3.97 1
2 0

6 mtg. holes/
slots
for #10 screws

Approvals
Underwriters Laboratories, Inc. recognized component Canadian Standards Associations (CSA) Guide Number
for air conditioning, refrigeration, and resistance heating 361-E0.2, File Number LX18156-39.
equipment. File Number #E6591. Guide Number NLDX2.

H6
DP-Definite Purpose Control Engineering Data
Dimension - DP33 (Two 3-Pole Mechanically & Electrically Interlock Contactors)

Typical wiring diagram for Electrically held Reverser using Mechanically Interlocked Push Buttons. H
Electrically Held Contactors and Mechanically
Interlocked Pushbuttons Using Two SPDT
Auxiliary Contacts.

Four additional auxiliary contacts may be


factory
added. Two may be field added.

Coil Characteristics
4
Coil D-C Approvals 1
Volts Inrush Sealed Pick-up Resistance 0
Underwriters Laboratories, Inc. recognized
50/60Hz VA VA Volts Ohms component for air conditioning, refrigeration and
24 48 8.4 16 6.5 resistance heating equipment. File number
120 48 8.4 80 170 E6591. Guide number NLDX2.
208-240 48 8.4 160 680
Coil insulation - Class B Canadian Standard Association (CSA) Guide
Coil connections - Double male 1/4" quick connect number 361-E0.2, File number LX18156-39.
Maximum ambient - 155oF

H7
Index DC Control

Description Page Number


Index ........................................................................... J1
146 Field Loss Relay .................................................. J2
5 DP Series - General Information ............................... J3
Contactors - 1, 2, 3 Pole .............................................. J4
Accessories ................................................................ J5
Dimensions Data ........................................................ J7
7400 Contactors ......................................................... J8
7400 Accessories & Dimensions Data....................... J9
RHEOSTATS ............................................................ J10

J1
DC Control 146 Field Loss Relay
Series 146 Relays provide excellent protection against overspeeding on
DC shunt or compound wound motors in the event of an open circuit in the
field. The relay coil is connected in series with the shunt field while the re-lay
motor contacts are in the motor control circuit. The relay coil is de-energized
if the field opens and the relay contacts open to disconnect the motor from
line. Where shunt or compound wound motors are operated at light loads or
not rigidly connected to the load, field loss relays provide protection against
motor and load damage from overspeeding. The Series 146 Relay is a UL
recognized component.
Coils are designed to carry maximum field current continuously. Relays are
factory adjusted to pick-up at one tenth of the maximum field current amps.
listed. Drop-out is approximately 62% of the pick-up value. Other pick-up
values on special order.

Field Loss Relays (DC) - 146 300V DC Max.


Max. Field Relay Relay Max. Field Relay Relay
Current Pick-Up Drop-Out Current Pick-Up Drop-Out
Amps Amps Amps Catalog No. Price Amps Amps Amps Catalog No. Price
.25 .025 .0155 146-25 $ 660. 8.0 .800 .496 146-800 $ 660.
.5 .050 .031 146-50 660. 9.0 .900 .559 146-900 660.
1.0 .100 .062 146-100 660. 10.5 1.050 .651 146-1050 660.
1.5 .150 .093 146-150 660. 12.0 1.200 .744 146-1200 660.
2.0 .200 .124 146-200 660. 13.5 1.350 .836 146-1350 660.
2.5 .250 .155 146-250 660. 15.0 1.500 .930 146-1500 660.
3.0 .300 .186 146-300 660. 22 2.200 1.320 146-2200 764.
4.0 .400 .248 146-400 660. 27 2.700 1.620 146-2700 764.
5.0 .500 .310 146-500 660. 35 3.500 2.100 146-3500 764.
J 6.0
7.0
.600
.700
.372
.434
146-600
146-700
660.
660.
65
80
6.500
8
4.000
4.96
146-6500
146-8000
764.
1180.

Engineering Data: Dimensions -Approximate

0
1
3

Ordering Information
Use complete catalog number when ordering.
Contact Rating: Single pole double break normally open contacts, rated at 0.7 amps., 250 V DC Max.

J2 Discount Schedule JC 21
5DP Contactors DC Control
5DP Definite Purpose Contactors are designed for DC adjustable contactor may be required to interrupt up to 200% current. The N.O.
speed drive circuits using silicon controlled rectifier switching and contacts are equipped with permanent magnet blowouts to meet this
other controls where a combination of normally open and normally requirement.
closed power contacts are required. In all applications, reduced
panel space for contactor mounting is made possible through a The dynamic brake N.C. contact is required to insert the dynamic
compact design and the built-in N.C. dynamic brake power contact brake resistor and therefore must make up to 200% of rated current
feature. each time the contactor is deenergized.
In silicon controlled rectifier switching circuits, the SCR is normally Jogging is accomplished at low voltage and current. Therefore, the
phased back prior to contactor opening. Therefore, the N.O. contacts dynamic brake contact is rated at 1/3 of rated voltage and dynamic
are not required to interrupt any appreciable current. Under abnormal brake current. The permanent magnet blowouts provide this inter-
conditions such as failure of the SCR or the control circuit, the rupting ability.

1. Normally Closed Double Break Power Contacts - made of silver 6. Molded Coil - is layer wound, designed for continuous duty service.
cadmium oxide furnish "anti-weld" protection under overload conditions. Coil construction resists moisture; thermal and mechanical stress. Coil
Generous size contacts are long lasting, and maintenance-free. All N.C. connections are made to pressure type terminals.
power contacts supplied with permanent magnet blowouts to lengthen 7. Free-Floating Armature-Magnet Frame - provide quiet, low vibra-
contact life. tion, low friction operation. Precision ground pole faces achieve an
2. Normally Open Double Break Power Contacts - incorporate the absolute air gap which prevents "hanging-up". Magnet frame is sized
same design features as the normally closed power poles. Permanent for fast, powerful operation and self-seating extends operational life.
magnet blowouts are also furnished on d.c. load applications. 8. Auxiliary Contacts - for 10/40 amp. contactors are available with with
3. Permanent Magnet Blowouts - mounted to surround the power either the front mounted snap action type with quick connect terminals
contacts, function to quickly quench the arc when breaking loads, or the side mounted type with pressure terminals. Contacts for larger
thereby increasing contact life and assuring positive load circuit interrup- sizes in standard or special make-before-break contact combinations
ton. All normally closed poles are furnished with permanent magnet feature either standard double break silver-to-silver contacts or low
blowouts. Normally open poles can be supplied with or without blowouts power gold alloy contacts.
as indicated in the circuit symbols shown on page J6. 9. Pressure Type Terminals - accessible, up-front location permits
4. Stainless Steel Springs - maintain exact contact pressure and modern straight-thru wiring. Terminals accept stripped, unlugged wires.
assure fast contact break (N.O.) and make (N.C.).
5. Molded Housing - constructed of hot-molded, high impact, high arc
resistant insulating material. This design totally encloses the contacts
and operating magnet in separate compartments and functions to
eliminate internal phase-to-phase short circuits.

J3
DC CONTROL 5DP Contactors
SCR Drive Contactors - N.O. or N.C. Power Poles
Drive Contactors Preferred Style 500 VDC Max
Type & Poles Open Type Drive Contactors - Old Style
Rating N.O. N.C. Fig.No. Catalog No. Price For New Installations Use Preferred Style
7001 0 1 7A 7001-5150- * * $208.
Type & Poles Open Type
0 2 9 7001-5230- * * 269.
Rating N.O. N.C. Fig.No. Catalog No. Price
40 1 0 1 7001-6050- * * 179.
7000 0 1 7A 7000-5150- * * $ 208.
amp. 2 0 3 7001-7030- * * 227.
10/40 2 0 3 7000-7030- * * 227.
2 1 10 7001-7140- * * 296. 2 1 10 7000-7140- * * 296.
amp.
5DP7 0 1 7A 5DP7-5150- * * 756. 0 1 8 5DP1-01( *)00 416.
0 2 9 5DP7-5230- * * 1040. 0 2 9 5DP1-02( *)00 491.
5DP1
75 1 0 1 5DP7-6050- * * 693. 1 0 1 5DP1-10( *)00 378.
amp. 2 0 3 5DP7-7030- * * 924. 1 1 5 5DP1-11( *)00 441.
30 2 0 2 5DP1-20( *)00 403.
2 1 10 5DP7-7140- * * 1210.
amp. 2 1 6 5DP1-21( *)00 466.
5DP3A 0 1 8 5DP3A4001-* * 895.
2 0 3 5DP1-5021- * * 441.
0 2 9 5DP3A3071-* * 1323.
2 1 7 5DP1-5051- * * 504.
110 1 0 1 5DP3A4011-* * 857.
0 1 8 5DP2-01( *)00 630.
amp. 2 0 3 5DP3A5021-* * 1176. 0 2 9 5DP2-02( *)00 920.
2 1 15 5DP3A5091-* * 1502. 1 0 1 5DP2-10( *)00 605.
5DP2
5DP4 0 1 8 5DP4-4001- * * 1222. 1 1 5 5DP2-11( *)00 857.
0 2 9 5DP4-3071- * * 1812. 2 0 2 5DP2-20( *)00 794.
56
180 1 0 1 5DP4-4011- * * 1058. 2 1 6 5DP2-21( *)00 895.
amp. 2 0 3 5DP2-5021- * * 832.
amp. 2 0 3 5DP4-5021- * * 1533.
2 1 15 5DP4-5091- * 2104. 2 1 7 5DP2-5051- * * 935.
* 0 1 8 5DP3-01( *)00 895.
5DP9 0 1 8 5DP9-4001- ** 1676. 5DP3 0 2 9 5DP3-02( *)00 1323.
0 2 9 5DP9-3071- ** 2405. 1 0 1 5DP3-10( *)00 857.
260 1 0 1 5DP9-4011- ** 1481. 110 1 1 5 5DP3-11( *)00 1176.
amp. 2 0 3 5DP9-5021- ** 2066. 2 0 2 5DP3-20( *)00 1109.
amp.
2 1 2 1 6 5DP3-21( *)00 1439.
15 5DP9-5091- ** 2793.
2 0 3 5DP3-5021- * * 1172.
5DP5 0 1 8 5DP5-4001- ** 3024.
2 1 7 5DP3-5051- * * 1502.
0 2 9 5DP5-3071- ** 4788.
0 1 8 5DP4-01( *)00 1222.
360 1 0 1 5DP5-4011- ** 2772.
5DP4 0 2 9 5DP4-02( *)00 1817.
amp. 2 0 3 5DP5-5021- ** 4410. 1 0 1 5DP4-10( *)00 1058
J 5DP8
2
0
1
1
15
8
5DP5-5091-
5DP8-4001-
**
**
6048.
3402.
180 1
2
1
0
5
2
5DP4-11( *)00
5DP4-20( *)00
1628.
1470
amp.
0 2 9 5DP8-3071- ** 5544. 2 1 6 5DP4-21( *)00 2041.
535 1 0 1 5DP8-4011- ** 3150. 2 1 7 5DP4-5051 * * 2104.
amp. 2 0 3 5DP8-5021- ** 5040.
0 1 8 5DP9-01( *)00 1676.
2 1 15 5DP8-5091- ** 7497. 5DP9 0 2 9 5DP9-02( *)00 2405.
5DP6 0 1 8 5DP6-4001- ** 5040. 1 0 1 5DP9-10( *)00 1481.
0 2 9 5DP6-3071- ** 9576. 260 1 1 5 5DP9-11( *)00 2192.
700 1 0 1 5DP6-4011- ** 4410. amp. 2 0 2 5DP9-20( *)00 2003.
amp. 2 0 3 5DP6-5021- ** 7938. 2 1 6 5DP9-21( *)00 2730.
2 1 15 5DP6-5051- 11970. 2 1 7 5DP9-5051- * * 2797.
**
0 1 8 5DP5-01( *)00 3024.
5DP5
* Coil Table #1 Replace * with appropriate coil voltage digit. 0 2 9 5DP5-02( *)00 4788.
1 0 1 5DP5-10( *)00 2772.
60 Hz/Voltage ( ) DC/Voltage ( ) 360 1 1 5 5DP5-11( *)00 4410.
* * amp. 2 0 2 5DP5-20( *)00 4032.
120 1 115 8 2 1 6 5DP5-21( *)00 5670.
240 2 230 9 2 1 7 5DP5-5051- * * 6048.
5DP8 0 1 8 5DP8-01( * )00 3402.
0 2 9 5DP8-02( * )00 5544.
* * Coil Table #2 Replace ** with appropriate coil voltage suffix
1 1 5 5DP8-11( * )00 5040.
535
2 0 2 5DP8-20( * )00 4662.
60 Hz/Voltage Suffix DC/Voltage Suffix amp. 4
2 1 6 5DP8-21( * )00 7119. 8
2 1 7 5DP8-5051- * * 7497. 5
120 11 12 72 0 1 8 5DP6-01( *)00 5040.
208/240 21 24 82 5DP6
0 2 9 5DP6-02( *)00 9576.
208 90 48 32 1 0 1 5DP6-10( *)00 4410.
240 21 120 12 700 1 1 5 5DP6-11( *)00 8442.
480 41 240 22 amp. 2 0 2 5DP6-20( *)00 7434.
600 51 2 1 6 5DP6-21( *)00 11466.

The N.C. contact is short time rated for Dynamic Braking


For all DC Coils up to 260 Amp add $202., for 360 & 535 Amp.
applications. Refer to table on page J7 for N.C. contact ratings.
add $328., 700 Amp. deduct -$504.00

J4 Discount Schedule JC20


DC Control 5DP Contactors
Auxiliary Contact Blocks Reversing Kits
Factory Field Installation Description Kit No Price
Installed Kit
Mechanical interlock 5M115 $ 76.
Description Addition Kit No. Price
10/40 amp. & 40 amp.
Front mtd. aux. 10/40 amp. Old Style & 40A. Mechanical interlock 5999-4737 76.
N.O. - N.C. right hand front mtg. 76. 5999-3504 38. 30-260 amps. contactors
N.O. - N.C. left hand front mtg. 76. 5999-3604 38. except 75 amp.
N.O. - N.C. for multiple front mtg. 76. 5999-37041 38. Mechanical interlock 5999-4717 76.
For 10/40 amp. Old Style & 40-535 Amp. 75 amp. contactors
N.O. 101. 5M63 50. Mechanical interlock 5999-4757 315.
N.C. 101. 5M64 50. 360 & 535 amp.
N.O. & N.C. 139. 5M65 88. Mechanical interlock for two 5999-4767 630.
N.O. low power . 227. 5M63L 176. 3-pole 700 amp. contactors
N.C. low power. 227. 5M64L 176. Mechanical interlock for two 700 5M96 630.
N.O. & N.C. low power. 353. 5M65L 302. amp. contactors (1Pole
N.O. Standard & N.C. low power. 277. 5M66 227. & 2-Pole)
N.O. low power & N.C. standard. 277. 5M65L0 227. Reversing baseplate for 5999-8568 50.
N.C. late break. 101. 5M64E 50. 10/40 & 40 amp. contactors
N.O. & N.C. late break. 139. 5M68 4 88. Reversing baseplate for 30, 5999-8569 69.
N.C. lower power late break. 227. 5M64LE 176. 56 & 75 amp.
N.O. & N.C. low power late break. 277. 5M67 4 227. Reversing baseplate for 5999-8570 88.
N.O. low power & N.C. low power late break. 347. 5M69 4 302. 110,180 & 260 amp.
Tandem mounting auxiliary. * * 38. 5M60DA2 32. contactors
For 700 amp. Reversing baseplate for 360 & 5999-8571 189.
Bi-Pole (N.O. & N.C.) . 416. 5999-31633 151. 535 amp. contactors
N.O. low power . 391. 5999-33613 126. Reversing baseplate for two 5999-8572 315.
N.C. low power . 391. 5999-33623 126. 3-Pole 700 amp.contactors
N.O. & N.C. late break. 416. 5M46 151. Reversing baseplate for one 5999-8573 315.
Bracket for mounting two additional contact 391. 5999-3969 63. 2-Pole 700 amp. & one 3-Pole
blocks. 700 amp. contactors
NOT for 10/40A or 40A For 2, 2 Pole 700 Amp 5999-8580 315.
** NOTE:
1 . Kit includes one N.O. - N.C. auxiliary plus mounting hardware for
Auxiliary Contact Blocks contain 1 or 2 contact depending installing 3rd and 4th auxiliary.
on the type ordered, the table below lists max. # of contact
blocks for each contactor rating.
2 . Contains mounting hardware only. Order auxiliary separately.
3 . Without mounting bracket. Bracket required for mounting more than
J
Maximum one extra auxiliary
Maximum
Front Mtd Side Mtd Aux. interlock.
Front Mtd Side Mtd Aux.
Amps LHS RHS LHS RHS Contacts N.O. N.C. Amps LHS RHS LHS RHS Contacts N.O. N.C. 4. Not for use on 10/40, 40
& 75 Amp.
10/40 A 15 1 5 or 1 1 4= 5 2 2 180 A 0 0 2 2 8= 4 4 5. If DC coil required then
30 A 0 0 1 1 4= 2 2 260 A 0 0 2 2 8= 4 4 front Mtd Auxiliares not
40 A 15 1 5 or 1 1 4= 5 2 2 360 A 0 0 2 2 8= 4 4 available & contact
56 A 0 0 2 2 8= 4 4 535 A 0 0 2 2 8= 4 4 blocks restricted to 2 &
75 A 0 0 2 2 8= 4 4 700 A 0 0 2 1 6= 3 3 max. aux. contacts 4. 1
110 A 0 0 2 2 8= 4 4 contact listed also
used to economise coil
when DC operated.
Terminal Polarity and Wiring Figures:

Symbols: N.O. Contact Contact with Blowout N.C. Contact + Positive Polarity
Contacts without blowouts do not have any interrupting rating. Contactors with 2 N.O. contacts and blowouts will interrupt 200% current under
abnormal conditions.

Discount Schedule JC20 J5


5DP6 Accessories DC Control
1
Contact Kits - 5DP Coil Kits - 5DP (AC)
Contactor N.O. Contact N.C. Contact Volts V.A. -60Hz (Approx)
Type Rating Kit No. Price Kit No. Price Rating 50/60Hz Inrush Sealed Kit No . 3 Price
7000, 10/40A 5M19 $83. 5M20 $83. 7000 120 120 28 5ML25 $ 53.
7001 40A 10/40 A 208 120 28 5ML26 53.
5DP1 30A 5M55 83. 5M57 90. 7001 240 120 28 5ML29 53.
5DP2 56A 5M52 173. 5M58 248. 40A 480 120 28 5ML27 53.
5DP7 75A 5999-2521 131. 5M48 166. 600 120 28 5ML28 53.
5DP3A 110A 5M80A 207. 5M58 248. 5DP1 30 A 120 234 36 5ML21 110.
5DP3 110A 5M53 207. 5M49 228. 5DP2 56A 240 264 41 5ML22 110.
5DP4 180A 5M54 386. 5M49 228. 5DP3A 480 245 37 5ML23 110.
5DP9 260A 5M56 552. 5M49 228. 110A 600 246 36.6 5ML24 110.
5DP5 360A 5M-045 803. 5999-2461 580. 120 290 48 5999-1801 76.
5DP8 535A 5999-2371 1012. 5999-2461 580. 5DP7 75 A 208 290 48 5999-1805 76.
5DP6 700A 2
5999-2381 1553. 5999-2481 1553. 240 290 48 5999-1802 76.
480 290 48 5999-1803 76.
5 600 290 48 5999-1804 76.
DC Power Pack Kits - AC Coils 5DP3 110A 120 672 62.4 5ML41 156.
Volts 5DP4 180A 208/240 672 69.6 5ML42 156.
Rating 60Hz Kit No . Price 5DP9 260A 480 672 67.2 5ML43 156.
5DP6 120 5999-8061 $ 621. 600 683 72 5ML44 156.
700 amp. 240 5999-8062 621. 120 1725 151 5ML51 322.
480 5999-8063 621. 5DP5 360A 208/240 1750 138 5ML52 322.
480 1776 144 5ML53 322.
NOTE: 5DP8 535 A 600 1782 145 5ML54 322.
For all DC Coils up
Auxiliary Contact Rating 120 566 187 5999-1601 1656.
to 260 Amp add 10/40 Thru 100A 208/220 530 156 5999-1604 2185.
$221., for 360 & 535 AC Amperes 480 528 177 5999-1602 2185.
Amp. add $359., Volts Continuous Inrush 4,5, 6 120V DC 5999-1601 1656.
700 Amp. deduct - 120 6 60 5DP6 240V DC (1-pole N.O.) 5999-1602 2185.
$552.00 280 3 30 700A 240V DC (for 1-pole N.C.; 5999-1602 2185.
480 1.5 15 2-pole N.C.; 2-pole N.O. 5999-1602 2185.
600 1.2 12 2-pole N.O. & 1-pole N.C) 5999-1603 2185.
Contact Ratings
J DC Contact Rating - Amperes 7
N.O. Contac ts N.C. Contac ts (intermittent N.O. Contacts N.C. Contacts (intermittent
duty) Dynamic Bra ke Jogging duty) Dynamic Br ake Jogging
Type & Make Onl y - Brea k Onl y Type & Ma ke Only - Break Only
Rating Poles 240V 500V 500V Ma x. 160V Ma x. Rating Poles 240V 500V 500V Ma x. 160V M a x.
7000 2 ---- 10 20 7 5DP4 1 180 ---- 315 105
10/40 amp. 2 40 ---- 80(240V) 27(80V) 180 amp. 2 180 180 ----- ----
7001 2 40 40 70 23 5DP9 1 ---- ---- 387 135
40 amp. 260 amp. 2 260 260 ----- ----
5DP1 1 30 30 54 20 5DP5 1 360 360 720 240
30 amp. 2 30 30 ----- ---- 360 amp. 2 360 360 ----- ----
5DP2 1 56 56 105 35 5DP8 1 ---- ---- 1070 356
56 amp. 2 56 56 ----- ---- 535 amp. 2 535 535 ----- ----
5DP7 2 75 75 150 50 5DP6 1 700 700 1400 466
75 amp. 700 amp. 2 700 700 ----- ----
5DP3 1 110 ---- 315 105
5DP3A
110 amp. 2 110 110 ----- ----

Note:
1. Contact Kits for 1-pole include stationary contacts, movable contacts 5. Power pack assembly kit includes rectifier, economizing resistor and
and contact spring except as noted for 700 amp. size. terminal block. Power Pack Kit must be used on all DC operated 5DP6 units
2. Assembled kit for 1-pole including yoke with movable contacts and 6. Values measured at rectifier power pack input.
springs; stationary contacts. 7. It is necessary to phase back the SCR's so that contactor normally
3. For all pole combinations except 2-pole N.C. does not interrupt appreciable current. Contactors with blowouts and
4. These coils are for exact replacement at operating voltage and 2 N.O. contacts will interupt 200% current under abnormal conditions.
frequency listed.

J6 Discount Schedule JC27


DC Control Dimensions
Dimensions - Approximate
(Contactor base mounted vertically)

For side mounted auxiliary contact blocks add


1/2" per side to width dimension for all
contactor sizes.

10/40 amp. contactor - 7000 10/40 amp. contactor - 7000


40 amp. contactor - 7001 40 amp. contactor - 7001
with front mounted auxiliary with side mounted auxiliary

260 amp. contactor - 5DP9

75 amp. contactor - 5DP7

360 & 535 amp. contactor - 5DP5 & 5DP8

110 amp. contactor - 5DP3A


30 & 56 amp. contactor - 5DP1 & 5DP2

4
5
5

110 amp. contactor - 5DP3 700 amp. contactor - 5DP6


180 amp. contactor - 5DP4

J7
General Information DC Control - 7400

DC Contactors in sizes 1 Thru 5 are for use as main line, reversing or


accelerating contactors in DC motor starters and controllers. Other
applications include switching resistive heating and battery loads.
Description
All DC Contactors are solenoid operated for fast, constant, long-life
performance. Generous size double break silver cadmium oxide con-
tacts in combination with built-in permanent magnet blowouts assure
long contact life and positive circuit interruption. Terminal location makes
the contactors ideal for straight-through wiring and for wire channel
layouts. Accessible up-front pressure-type terminals are furnished as
standard.
Auxiliary Contacts
All contactors can be furnished with N.O., N.C. or N.O. & N.C. auxiliary contact blocks. Each contactor can be supplied with a maximum of
four auxiliary contact blocks. Kits are also available for field installtion.
Operating Coils
Standard coils for DC operation are molded and equipped with pressure type terminals. The DC coils are furnished with late break auxiliary
and economizing resistors as standard. AC coils can be furnished for applications requiring an AC control circuit.

250 Volts DC Max


8 - Hour Rating Open Type DC Coil Open Type DC Coil Open Type DC Coil
in Amps. 1 Pole N.O. 2 Pole N.O. 2 Pole N.O. & 1 Pole N.C.
Size Open Enclosed Catalog No. 2 Price Catalog No. 2 Price Catalog No. 2 Price
1 25 22.5 74014010- * $ 580. 7401-1020- * $ 643. 7401-3050- * $ 706.
2 50 45 74024010- * 806. 7402-1020- * 1033. 7402-3050- * 1134.
3 100 90 ----- 1 7403-1020- * 1373. 7403-3050- * 1701.
4 150 135 ----- 1 7404-1020- * 1739. 7404-3050- * 2306.
5 300 270 7405-4010- * 3100. 7405-1020- * 4360. 7405-3050- * 5998.
J Size Open Enclosed 1 Pole N.O. - AC Coil 2 Pole N.O. - AC Coil 2 Pole N.O. - 1 N.C. - AC Coil
1 25 22.5 7441-4010- * 378. 7441-1020- * 441. 7441-3050- * 504.
2 50 45 7442-4010- * 605. 7442-1020- * 832. 7442-3050- * 932.
3 100 90 ----- 1 7443-1020- * 1172. 7443-3050- * 1499.
4 150 135 ----- 1 7444-1020- * 1537. 7444-3050- * 2104.
5 300 270 7445-4010- * 2772. 7445-1020- * 4032. 7445-3050- * 5670.

Auxiliary Contact Ratings


DC Amperes AC Amperes
Note:
Volts Normal Volts Normal Inrush
1. On Sizes 3 & 4 only for single pole applications use two poles in
125 1.1 120 6.0 60 series and for two pole applications use one pole in each line.
250 0.55 240 3.0 30 2. Contactor furnished without auxiliary contact. See Modifications
480 1.5 15 & Accessories.
600 1.2 12

4
8
5
Ordering Information Coil Table
Use complete catalog number. AC 60Hz/Voltage Suffix DC Voltage Suffix
Replace the (*) with the suffix from 120 11 24 82
the coil table. 208/240 21 48 32
480 41 120 12
600 51 240 22

J8 Discount Schedule JC20


DC Control - 7400 Accessories & Dimensions
Modification & Accessories
3
DC Coils Discount Schedule JC 27 Discount Schedule JC 20

NEMA Description Kit No. Price


1
Size Voltage Kit No. Price Kits For Field Installation:
120 5999A-2931 $ 186. N.O. Aux. 5M63 $ 50.
1&2
240 5999A-2932 186. N.C. Aux 5M64 50.
120 5999A-2941 232. N.O. & N.C. Aux 5M65 88.
3&4
240 5999A-2942 232. N.C. Late Break Aux. 5M64E 50.
3 Mechanical Interlock - Size 1-4 5999-4737 76.
AC Coils Size 5 5999-4757 252.
NEMA 50/60Hz Reversing Base Plate:
Size Volts Kit No. Price NEMA Sizes 1 & 2 23082.79-1 69.
120 5ML21 $ 110. NEMA Size 3 & 4 23083.30-1 88.
240 5ML22 110. NEMA Size 5 23085.312-1 189.
1&2 101.
480 5ML23 110. N.O. or N.C. Aux. Contact Installed
600 5ML24 110. N.O. &e N.C. Aux. Contact Installed 139.
120 5ML41 156.
3&4 240 5ML42 156. Contact Kits - (For 1-Pole) Discount Schedule JC 27
480 5ML43 156.
N.O. Contacts N.C. Contacts
600 5ML44 156.
Size Kit No . 2 Price Kit No . 2 Price
120 5ML51 276.
1 5M55 $ 83. 5M57 $ 90.
240 5ML52 322.
2 5M52 173. 5M58 248.
5 480 5ML53 322.
3 5M53 207. 5M49 228.
600 5ML54 322.
4 5M54 386. 5M49 228.
5 5999-0045 803. 5999-2461 580.
Notes:
1. Coil Kits include economizing resistor and normally closed late break auxiliary.
2. Kits include stationary contacts, movable contacts and contact spring.
3. For special coils refer to factory.

DIMENSIONS - Approximate
(Contactor base must be mounted vertically) J

25 and 50 amp. contactor


Dimension A: 5 1/8" for size 1
5 3/8" for size 2

300 amp contactor


Size 5

100 and 150 amp. contactor


Size 3 & 4

Discount Schedule JC20 & JC27 J9


RHEOSTATS
Vitrohm plate type
100-2000 WATTS 600 VOLT SERVICE

Fig. 1. Vitrohm pressed steel rheostat Fig. 2. 8" Vitrohm rheostat, Fig. 3. 8" Vitrohm rheostat,
for front-of-board mounting. Type S standard contacts, Type M multi-step contacts,
front-of-board mounting. front-of-board mounting.

STANDARD SIZE RHEOSTATS - 6", 8", 13" MOTOR DRIVE ACCESSORIES-Type SMD
TYPES S and M
APPLICATION
APPLICATION
Type SMD Accessories are for use with 8" or 13" rheostats
Vitrohm pressed steel rheostats furnish a simple, accurate where motor driven operation is required. Standard assem-
and economical method of field control. They are universally blies can be applied to drive up to four plates simultaneously.
applied for adjusting generator, alternator and exciter field cur- For larger 15 1/2" and 18" rheostats as well as the 13" size, a
rents to obtain variations in output voltage and for field control Type LMD large motor drive is available on order.
of adjustable speed D.C. and synchronous motors. Other typi-
cal applications include heater, furnace, battery charging and TO ORDER RHEOSTATS
other controls. * Consult Factory for price and availability
* If replacing and existing unit have the "K" number or serial
J 4" RHEOSTATS-300 Volt Max. Service number available.

APPLICATION FOR GENERATOR FIELD CONTROL SPECIFY:


1. Whether self-or separately-excited. If separately excited give
Vitrohm 4" rheostats for 300 volt max. service are specially voltage, field resistance (hot or cold) and minimum field cur-
designed for field and other control applications. rent. If self-excited state maximum field current and field resis-
tance (cold) under no load conditions, or peak generator volt-
age and field current at peak voltage and minimum generator
DANCER ROLL RHEOSTATS- voltage with field current at minimum volatge. For special con-
6, 8, 13 inch Types S and M trol requirements supply saturation curve.

APPLICATION 2. Open or enclosed


3. Type contacts
Series 60DR rheostats are for dancer roll service on multi-motor 4. Type accessory.
drives where relative speeds between the motors must be 5. Manual or motor drive
maintained within specified limits. Typical applications of these 6. Optional or special
field control rheostats include textile, paper, steel mills and oth-
ers in the process machinery field. FOR OTHER APPLICATIONS SPECIFY:

1. Maximum and minimum current 4


5
2. Rheostat resistance. 5
3. Open or enclosed
4. Type contacts
5. Type accesssory. If back-of-board mounting, state panel
thickness
6. Manual or motor drive.
7. Optional or special features required.

J10
Index Relays

Description Page Number


General Information ......................................................................... K2
PM AC Relays
PM Convertible, PMA, PMF, AC Relays.......................................... K4
PM Latching, PML, PMAL, AC Relays ............................................ K5
Pole Arrangement, Diagrams, PM, PMA, PMF ............................... K6
Dimensional Data, PM, PML, PMA, PMAL, PMF ............................ K7
PMS, Slim Jim AC Relays ............................................................... K8
PMT, AC Pneumatic Timing Relays .............................................. K10
PM Relay Parts and Modification Kits ........................................... K11
PM DC Relays
PM Convertible DC Relays ............................................................ K12
PML Latching DC Relays .............................................................. K13
PMT DC Pneumatic Timing Relays ............................................... K14
Dimensional Data DC Relays ........................................................ K16
Engineering Data........................................................................... K17
Series 447 Relays ......................................................................... K18

4
2
0

K1
PM - Relays General Information

The Joslyn Clark PM Family of control relays provides flexibility, versatility and reliability.
The exclusive design concept and rugged construction of the PM line offers many
advantages for the disigner and builder of today's complex control panels.

Features:
Modular Construction -allows field additon, replacement or Interchangeability of Parts - reduces inventory requirements.
conversion of poles for unlimited flexibility. Flexibility of Application - provided by many modifications
Uniformity of Design -simplifies engineering, installation including noble metal, gold bonded, anti-weld and overlapping
and maintenance. contacts.

K
Convertible Poles contain one contact, Universal Poles contain two independ- Duplex Poles contain two independent
either NO or NC and can be easily field ent isolated contacts, one NO and isolated contacts, both NO. Identified
converted from one to the other. one NC. Identified by RED operating by GREEN operating rod.
Identified be WHITE operating rod. rod.

4
2
0

PMS Slim Jim Relays are 1 - 1 1/2" wide. They are the smallest PM Convertible Pole Relays use white rod poles and are offered
members of the PM Family. Available with up to 4 contacts; with up to 8 contacts in any combination of NO and NC contacts.
they provide the reliability of heavy duty 600 Volt relays in the Relays with up to 12 contacts using double deck bases can be
smallest possible space. supplied.

K2
General Information Relays - PM

Type Relays, using universal poles have up to 12 contacts. Relays


with up to 14 contacts are available, using some convertible poles.
Type PMF Relays, combining several types of poles can have up to 14
contacts.

Type PMT Pheumatic Timing Relays, these relays are available for
either "on-delay" operation (time delay after energization) or "off-
K
delay" (time delay after de-engerization). They may also be field
converted from on to "off-delay" and vice versa, by merely
inverting the opertaing magnet. Type PMT Time Delay relays are
adjustable over a timing range from 0.2 seconds to 3 minutes with
repetitive accuracy of + 10%.

4
2
0

Latch Relays are available with either white rod convertible poles
or red rod universal poles. The latching unit with continous duty
trip coil replaces the two pole modules directly above the relay
magnet.

K3
PM - Relays AC Relays
Type PM Convertible, PMA Universal, PMF Duplex

Type PM Relays Type PMA Relays Type PMF Relays


Convertible Pole Universal Pole Duplex Pole
1 2
Total Normally Normally White Operating Rod Red Operating Rod Green Operating Rod
No. of Open Closed Catalog Catalog Catalog
4
Contacts Contacts Contacts Number Price Number Price Number Price
2 0 5U2 * $ 180. — — — —
2 1 1 5U2-1 * 216. — — — —
0 2 5U2-2 * 216. — — — —
3 0 5U3 * 216. — — — —
3 2 1 5U3-1 * 252. — — — —
1 2 5U3-2 * 252. — — — —
0 3 5U3-3 * 252. — — — —
4 0 5U4 * 240. — — 5UFK4 * $ 204.
4 3 1 5U4-1 * 276. — — 5UFK4-1 * 240.
2 2 5U4-2 * 276. 5UU2 * * $ 216. — —
1 3 5U4-3 * 276. — — — —
0 4 5U4-4 * 276. — — — —
6 0 5U6 * 360. — — 5UF6 * 300.
5 1 5U6-1 * 396. — — 5UF6-1 * 336.
4 2 5U6-2 * 396. — — 5UF6-2 * 336.
6 3 3 5U6-3 * 396. 5UU3 ** 252. — —
2 4 5U6-4 * 396. — — — —
1 5 5U6-5 * 420. — — — —
0 6 5U6-6 * 420. — — — —
8 0 5U8 * 432. — — 5UF8 * 360.
7 1 5U8-1 * 468. — — 5UF8-1 * 396.
6 2 5U8-2 * 468. — — 5UF8-2 * 396.
8 5 3 5U8-3 * 468. — — 5UF8-3 * 396.
4 4 5U8-4 * 468. 5UU4 * 282. — —
3 5 5U8-5 * 492. — — — —
2 6 5U8-6 * 492. — — — —
1 7 5U8-7 * 492. — — — —
0 8 5U8-8 * 492. — — — —
10 0 — — — — 5UF10 * 528.
K 10 9
8
1
2








5UF10-1
5UF10-2
*
*
528.
528.
7 3 — — — — 5UF10-3 * 528.
12 0 — — — — 5UF12 * 664.
11 1 — — — — 5UF12-1 * 688.
12 10 2 — — — — 5UF12-2 * 688.
9 3 — — — — 5UF12-3 * 688.
6 6 — — 5UU6 * 628. — —
14 0 — — — — 5UF14 * 736.
13 1 — — — — 5UF14-1 * 772.
12 2 — — — — 5UF14-2 * 772.
11 3 — — — — 5UF14-3 * 772.
14 10 4 — — — — 5UF14-4 * 772.
9 5 — — — — 5UF14-5 * 772.
8 6 — — 5UU86 * 700. — —
7 7 — _ 5UU77 * 740. — —
6 8 — — 5UU68 * 740. — —
4
Alternate 2 0 5UK2 * 180. — — — — 2
0
Layout 2 1 1 5UK2-1 * 216 — — — —
Alternate *
Layout 4 4 0 5UK4 240. — — — —
1 2
See notes 3,5 and 6 page K5 & K7 See note 2 page K5

Ordering Information
Use complete catalog no. replace the (*) with suffix from coil Table, (Located on Page K5)

K4 Discount Schedule JC55


AC Relays Relays - PM

Type PM Latch Relays, PML Convertible, PMAL Universal


Type PML Type PMAL
Convertible Pole Universal Pole
Total Normally Normally White Operating Rod Red Operating Rod
No. of Open Closed Catalog Catalog
4
Contacts Contacts Contacts Number Price Number Price
2 0 5UH2 * $350. — —
2 1 1 5UH2-1 * 384. — —
0 2 5UH2-2 * 384. — —
3 0 5UH3 * 384. — —
3 2 1 5UH3-1 * 420. — —
1 2 5UH3-2 * 420. — —
0 3 5UH3-3 * 420. — —
Latch Relays 4 0 5UH4 * 408. — —
The latch unit occupies the space of two poles 3 1 5UH4-1 * 444. — —
directly above the magnet, and provides a 4 2 2 5UH4-2 * 444. 5UUH2 * $384.
means of holding the relay in the energized 1 3 5UH4-3 * 444. — —
position after the coil of the main operating 0 4 5UH4-4 * 444. — —
magnet is de-energized. Momentarily
energizing the continous duty coil of the latch
6 0 5UH6 * 528. — —
unit allows the relay to return to the normal, de-
5 1 5UH6-1 * 564. — —
energized position.
4 2 5UH6-2 * 564. — —
6 3 3 5UH6-3 * 564. 5UUH3 * 420.
2 4 5UH6-4 * 564. — —
1 5 5UH6-5 * 588. — —
0 6 5UH6-6 * 588. — —
8 4 4 — — 5UUH4 * 450.
6 4 — — 5UUH64 * 688.
10 5 5 — — 5UUH55 * 724.
4 6 — — 5UUH46 * 724.

1
Maximum of 8 contacts only on 25 hz.
2
Relay Enclosure P6E-01 $80.00
PMF relays with N.C. contacts have universal red
rod & duplex green rod poles. Maximum of 8

3
contacts only on 25 hz. K
Price includes open type relay complete with
operating coil. Latching relays include latch unit
with continuous duty trip coil.
4
Overlapping contacts are available at $120.00 list per
pair. Specify when ordering.
5
For Dimensions, refer to page K7 For modifica-
ion Kits, refer to page K11.
6
Additional relays with alternate pole configurations
available.

5U4B - * 4 pole base only $114


5U8B - * 8 pole base only $144

Ordering Information * Suffix Coil Table


4
2 Use complete catalog number. Replace the (*) with suffix coil table. Hertz
0 Volts 60 50 25
Ex. 4 Pole Relay with 120V, 60Hz. coil; 5UH4-76.
Latch Relays are supplied with main coil and latch coil of the same 24 —96 —95 —92
voltage. For variations, consult factory. 110-120 —76 —75 —72
220-240 —26 —25 —22
380 —36 —35 —32
440-480 —46 —45 —42
550-600 —56 —55 —52

Discount Schedule JC55 K5


PM - Relays AC Relays

Contact Arrangement

Type PM Convertible Pole Relays


Numbers in pole locations indicate the sequence in which
normally closed poles are mounted when required.

Type PMA Universal Pole Relays


Numbers in pole locations indicate the sequence in which
normally closed convertible poles are mounted when required.

Universal Pole -
Red Operating
Rod

Convertible Pole -
White Operating
K Rod

Type PMF Duplex Pole Relays


Numbers in pole locations indicate the sequence in Duplex Pole -
which Universal poles are mounted when required. 2 Contacts, both N.O.
Green Operating Rod

Convertible Pole -
1 Contact either N.O or N.C.
White Operating Rod
4
2
0

K6
Dimensional Data

K
PMS - Relays AC Relays

AC Relays - Slim Jim Type PMS - Bulletin 7305


Pole Open
Arrange- Contacts Rod Type
ment N.O. N.C. Description Color Cat. No. Price

1 0 1 Convertible Pole White 5SW * $ 144.

2 0 2 Convertible Poles White 5SWW * 180.

2 0 1 Duplex Pole Green 5SG * 156.

4 0 2 Duplex Poles Green 5SGG * 204.

1 1 1 Universal Pole Red 5SR * 168.

2 2 2 Universal Poles Red 5SRR * 216.

1 Universal Pole Red


3 1 and 5SRG * 228.
1 Duplex Pole Green

Relay Enclosure P6E-01 $80.00

Approximate Dimensions In Inches


Pole Symbols

Represents one Convertible Pole, which includes one


normally open contact. K
Represents one Duplex Pole, which includes two normally
open contacts.

Represents one Universal Pole, which includes two


contacts, one normally open and one normally closed.

Represents one space where a Convertible, Duplex or


Universal Pole may be added.

4
2
0

Ordering Information Coil Table


Use complete catalog number. Replace Engineering Data 60Hz Voltage Suffix 60 Hz Voltage Suffix
the (*) with the suffix from Coil Table. Modification page K9 24 Separate Control -96 200-240 -26
Example: Cat. No. 5SRR-76 (110-120 Volt, 120 Separate Control -76 440-480 -46
550-600 -56
60 Hertz).

K8 Discount Schedule JC55


AC Relays Relays - PMS
Pole Assemblies
Contacts Rod Pole Kit
N.O. N.C. Color Description Cat. No. Price
1 0 White Convertible Pole KPM-1A $ 36.
0 1 White Convertible Pole KPM-2A 36.
1 1 Red Universal Pole KPMA-1 54.
2 0 Green Duplex Pole KPMF-1 54.
1 0 Black Convertible Pole — KPM-21A 60.
Overlap Contacts
0 1 Black Convertible Pole — KPM-22A 60.
Overlap Contacts
1 0 White Convertible Pole — KPM-31A 48.
Anti-Weld Contacts
0 1 White Convertible Pole — KPM-32A 48.
Anti-Weld Contacts
1 1 Orange Overlap Contact KPMA-21 108.
1 1 Red Universal Pole — KPMA-2 78.
Anti-Weld Contacts
2 0 Green Duplex Pole — KPMF-2 78.
Anti-Weld Contacts
Universal Pole —
1 1 Orange Overlap. Anti- KPMA-22 132.
Weld Contacts

Relay Bases Only


Base
Coil Catalog 1
Voltage Hertz Number Price Approximate Dimensions In Inches
24 60 5S-96 K
110-120 60 5S-76
110 50 5S-75 NEMA Type 1 Enclosure
220-240 60 5S-26
220 50 5S-25 $120.
380 50 5S-46
440-480 60 5S-46
550-600 60 5S-56

1
Price listed for relay base includes magnet coil and mounting
plate, less poles.

Enclose P6E-01 $80.00

4
3
0
NEMA Type 4 & 12 Enclosure

Ordering Information Coil Data Coil Table


Use complete catalog number. Inrush volt-amperes (at 60 hertz) 61 60Hz Voltage Suffix 60 Hz Voltage Suffix
Holding volt-amperes (at 60 hertz) 16 24 Separate Control -96 200-240 -26
120 Separate Control -76 440-480 -46
550-600 -56

Discount Schedule JC55 K9


PMT - Relays AC Time Delay Relays
AC Pneumatic Time Delay Relays - Type PMT Bulletin 7313
Timing Range Adjustible From 0.2 Second To 3 Minutes - Accuracy + 10%
Contacts Open Type Relays
No. of Time Delay Instan.Aux. Universal
Oper'ng Univ. Pole 6
Mode Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price
On
Delay 1 1 None None 713UP *
Off 1 $600.
Delay 1 1 None None 713UPD *
On
Delay 1 1 1 1 713UPA *
Off 660.
Delay 2 1 1 1 1 713UPDA *
On
Delay 2 2 None None 713UPE *
Off 780.
Delay 2 2 None None 713UPDE *
On
Delay 1 1 2 2 713UPB *
Off 720.
Delay 3 1 1 2 2 713UPDB *
On
Delay 2 2 1 1 713UPF *
Off 840.
Delay 2 2 1 1 713UPDF *
On
Delay 1 1 3 3 713UPC *
Off 780.
Delay 1 1 3 3 713UPDC *
4
On
Delay 2 2 2 2 713UPG *
Off 900.
Delay 2 2 2 2 713UPDG *
Notes
1
Price includes open type relay complete with timing head and Enclose P6E-01 $80.00
K
operating coil. To complete Cat. No., add coil suffix.
2
On Delay - Timed interval occurs between energization of the
coil and actuation of timed contact.
3
Off Delay - Timed interval occurs betwen de-energization of the
coil and actuation of timed contact.
4
Each universal pole consists of two independent isolated contacts
suitable for 600 volts at opposite polarity.
5
Relays may be converted in the field from On Delay to Off Delay
and vice versa, using only a screwdriver. When this conversion is
made, normally open contacts become normally closed contacts and
vice versa.
6
On sketches showing universal pole arrangements:
Letters T indicate locations of time delay poles.
Letters I indicate locations of instantaneous poles.
Dotted lines indicated locations where universal poles may be
added. Class A relays may have two timed poles maximum. 0
2
3
Ordering Information Coil Table
Use complete catalog number. Replace Engineering Data 60Hz Voltage Suffix 60 Hz Voltage Suffix
the (*) with the suffix from Coil Table. Modification page K11 24 Separate Control -96 200-240 -26
Example: Cat. No. 713UPA (110-120 Volt, 120 Separate Control -76 440-480 -46
550-600 -56
60 Hertz).
Overlapping contacts are available in the
same contact block at $120. per pair.

K10 Discount Schedule JC55


Modification and Parts Relays - PM
Modification Kits for Type PM Family - Discount Schedule JC55
Catalog
Description Number Price
Kits for BUL. 7305 Type PM Convertible Pole Relays

Pole Kits (All are convertible)


N.O. Non-Overlap Contacts, Closed Top KPM-1A $ 36.
N.C. Non-Overlap Contacts, Closed Top KPM-2A 36.
N.O. Non-Overlap Contacts, Open Top KPM-3A 36.
N.C. Non-Overlap Contacts, Open Top KPM-4A 36.
N.O. Non-Overlap Contacts, Open Top, Double Ended Carrier KPM-5A 36.
N.C. Non-Overlap Contacts, Open Top, Double Ended Carrier KPM-6A 36.
N.O. Overlapping Contacts, Closed Top KPM-21A 60.
N.C. Overlapping Contacts, Closed Top KPM-22A 60.
N.O. Overlapping Contacts, Open Top KPM-23A 60.
N.C. Overlapping Contacts, Open Top KPM-24A 60.
N.O. Overlapping Contacts, Open Top, Double Ended Carrier KPM-25A 60.
N.C. Overlapping Contacts, Open Top, Double Ended Carrier KPM-26A 60.
N.O. Non-Overlap Anti-Weld Contacts, Closed Top KPM-31A 48.
N.C. Non-Overlap Anti-Weld Contacts, Closed Top KPM-32A 48.
N.O. Non-Overlap Anti-Weld Contacts, Open Top KPM-33A 48.
N.C. Non-Overlap Anti-Weld Contacts, Open Top KPM-34A 48.
N.O. Non-Overlap Anti-Weld Contacts, Open Top, Double Ended Carrier KPM-35 48.
N.C. Non-Overlap Anti-Weld Contacts, Open Top, Double Ended Carrier KPM-36 48.
N.O. Non-Overlap Gold Bonded Contacts, Closed Top KPM-41 90.
N.C. Non-Overlap Gold Bonded Contacts, Closed Top KPM-42 90.
N.O. Non-Overlap Gold Bonded Contacts, Open Top KPM-43 90.
N.C. Non-Overlap Gold Bonded Contacts, Open Top KPM-44 90.
N.O. Non-Overlap Gold Bonded Contacts, Double Ended Carrier KPM-45 90.
N.C. Non-Overlap Gold Bonded Contacts, Double Ended Carrier KPM-46 90.
Adapter Plate (to add 13th or 14th pole) KPM-15 18.

Kits for BUL. 7305 Type PMA Universal Pole Relays


Pole Kit - N.O. & N.C. Non-Overlap Contacts, Closed Top KPMA-1 54.
N.O. & N.C. Non-Overlap Anti-Weld Contacts, Closed Top KPMA-2 78.
N.O. & N.C. Overlapping Contacts, Closed Top KPMA-21 108.
N.O. & N.C. Overlapping Anti-Weld Contacts, Closed Top KPMA-22 132.
Kits for BUL. 7305 Type PMF Duplex-Pole Relays
Pole Kits - 2 N.O. Non-Overlap Contacts, Closed Top KPMF-1 54.
2 N.O. Non-Overlap Anti-Weld Contacts, Closed Top
Kit for BUL. 7305 Type PML or PMAL Latch Relays
KPMF-2 78.
K
Latch Kit, with coil - Specify trip coil voltage suffix: - 76 (110-120v 60hz).
—26 (220-240v 60hz), - 46 (440-480v 60hz). Specify other voltages KPMH-12 168.
Kits for BUL. 7313 Type PMT Timing Relays
Contact Operating Link for R.H. Timed Pole KPMT-1 18.
Contact Operating Link for Instantaneous Pole KPMT-2 18.
Contact Mounting Bracket and Arm Assembly (R.H.) KPMT-3 36.
Contact Mounting Bracket and Arm Assembly (L.H.) KPMT-4 36.

Renewal Parts Kits - Discount Schedule JC80

Renewal Parts Kits for BUL. 7305 Type PM Convertible Pole Relays Cat. No. Price
Contact Arm, Short (4 Pole) with screws KPM-7 23.
4 Contact Arm, Long (6 Pole) with screws KPM-8 32.
2 Assembled Magnet and Rod (Straight-End Bracket) A-c Relays KPM-9 152.
0
Assembled Magnet and Rod (Hooked-End Bracket) A-c Relays KPM-10 152.
Assembled Magnet and Core. 2,3 & 4 Pole D-c Relays (Includes Rod, Bracket
& Contact Arm) KPM-16 173.
Assembled Magnet and Core, 6 & 8 Pole D-c Relays (Includes Rod, Bracket
& Contact Arm) KPM-17 179.
Renewal Parts for BUL. 7313 Type PMT Timing Relays
Assembled Magnet and Rod (Folio 2 Relays) KPMT-10 301.
Timing Head (without dial) (Folio 2 Relays) KPMT-12 524.

Discount Schedule JC55 & JC80 K11


PM - Relays DC Relays

DC Relays - Type PM Bulletin 7304

time-proven advantages offered by the highly maximum reliability.


successful Bullentin 7305 Type PM A-C Relay. For long trouble-free relay life, the D-C coil on
For example, normally open poles are quickly Bullentin 7304 Relays is molded with tough
and easily convertible to normally closed and epoxy resin to keep out dirt and moisture, and
vice versa. Each pole is contained in its own to prevent physical damage. The magnet
molded housing mounted by a single screw. used is a vertical lift type with no springs that
Thus, each pole may be removed, installed or require adjustment. It is designed with pull-in
replaced individually without disturbing the characteristics that keep magnet slam to a
others. minimum.
The large double-break contacts are made of Extra wide pressure terminals are front
General Description fine silver alloy, and are rated for both mounted for ready accessibility. As many as
Bulletin 7304, Type PM, D-C Convertible inductive and resistive loads. The contacts three lugs for No. 12 wire can be connected to
Pole Relays feature many of the same are designed with wipe action to assure each terminal.
Bullentin 7304 Relays are available in 2,3,4,6
and 8-pole arrangements.
Total Poles2 Open Type
Number Contact Normally Normally Catalog
Of Poles Arrangement Open Closed Number Price3 Contact Ratings - 10 Amps Continuous
2 0 4U2 * $348. D-C Applications
2 1 1 4U2-1 * 384.
Ampere Interrupting Rating
0 2 4U2-2 * 384.
Resistive Load
3 0 4U3 * 396. Non-Inductive Inductive Load
3 2 1 4U3-1 * 432. Volts N.O. N.C. N.O. or N.C.
1 2 4U3-2 * 432.
64 or less 10 10 2.2
0 3 4U3-3 * 432.
120 8 6 1.1
4 0 4U4 * 420. 240 2 1 .55
3 1 4U4-1 * 456.
4 2 2 4U4-2 * 456. A-C Applications
1
0
3
4
4U4-3
4U4-4
*
*
456.
456.
Volts
110
Make Break
60 6
K
6 0 4U6 * 594. 220 30 3
5 1 4U6-1 * 630. 440 15 1.5
4 2 4U6-2 * 630. 550 12 1.2
6 3 3 4U6-3 * 630.
2 4 4U6-4 * 630. 4U4B - * 4 pole base only $276
1 5 4U6-5 * 666.
4U8B - * 8 pole base only $378
0 6 4U6-6 * 666.
8 0 4U8 * 666.
Note:
7 1 4U8-1 * 708. 1
Numbers in pole locations shown in sketches
6 2 4U8-2 * 708.
indicate the sequence in which normally closed
8 5 3 4U8-3 * 708.
poles are mounted when required.
4 4 4U8-4 * 708. 2
Normally open contacts may be changed in the
3 5 4U8-5 * 744.
field to normally closed and vice versa, using only
2 6 4U8-6 * 744.
a screw driver.
4
2
0

Ordering Information * Coil Table DC Voltage


Use complete catalog number. Replace Price addition of $30 per DC Voltage Suffix DC Voltage Suffix
the (*) with the suffix from Coil Table. relay. For 32 & 64 volt 12 012 95 095
Overlapping contacts are available in the coils , use coil suffix 32 24 024 120 120
same contact block at $108 per pair or 64. 48 048 240 240
Enclosures supplied separately

K12 Discount Schedule JC55


DC Latch Relays Relays - PM
DC Latch Relays - Type PML Bulletin 7305
Bullentin 7305, Type PML, D-C Latch Relays this is acccomplished. Up to 8 convertible poles
are identical in design, construction and in any combination of N.O. and N.C. contact
dimension to the Type PML, A-C Convertible arrangement are available for circuit use. The
Pole Latch Relays except they incorporate contracts can be readily converted in the field
the use of one "universal" pole on the relay from N.O. to N.C. operation, and vice versa.
to permit continouus application of voltage to The latch mechanism is the same rugged unit
the relay "Close" coil and latch "Trip" coil. used on Type PML-A-C latch relays.
The schematic diagram below illustrates how

Contact Ratings - 10 Amps Continuous


Total Poles2 Open Type
D-C Applications Number Contact Normally Normally Catalog
Amperes Interrupting Rating Of Poles Arrangement Open Closed Number Price3
Resistive Load 2 0 5UHD2 * $492.
Non-Inductive Inductive Load 2 1 1 5UHD2-1 * 528.
Volts N.O. N.C. N.O. or N.C.
0 2 5UHD2-2 * 528.
64 or less 10 10 2.2
3 0 5UHD3 * 538.
120 8 6 1.1
3 2 1 5UHD3-1 * 564.
240 2 1 .55
1 2 5UHD3-2 * 564.
A-C Applications
0 3 5UHD3-3 * 564.

Volts Make Break


4 0 5UHD4 * 552.
110 60 6
3 1 5UHD4-1 * 588.
220 30 3
4 2 2 5UHD4-2 * 588.
440 15 1.5 1 3 5UHD4-3 * 588.
550 12 1.2 0 4 5UHD4-4 * 588.
6 0 5UHD6 * 684.
5 1 5UHD6-1 * 720.
4 2 5UHD6-2 * 720.
Typical Circuit 6 3 3 5UHD6-3 * 720.
2 4 5UHD6-4 * 720.
Universal Pole (Kit Catalog No. 1 5 5UHD6-5 * 744.
KPMA-21). Normally closed 0 6 5UHD6-6 * 744.
contact connected in series with relay
"Close" coil. Normally open contact
8
7
0
1
5UHD8
5UHD8-1
*
*
768.
804.
K
connected in series with relay "Trip" 6 2 5UHD8-2 * 804.
coil as shown below. Permits continuous 8 5 3 5UHD8-3 * 804.
application of voltage to the coil circuits. 4 4 5UHD8-4 * 804.
3 5 5UHD8-5 * 828.
2 6 5UHD8-6 * 828.
1 7 5UHD8-7 * 828.
0 8 5UHD8-8 * 828.

Note:
1
Numbers in pole locations shown in sketches Relay pole connot be
indicate the sequence in which normally closed located here.
poles are mounted when required.
2
Normally open contacts may be changed in the
field to normally closed and vice versa, using only
4 a screw driver.
2
0

Ordering Information Coil Table DC Voltage


Use complete catalog number. Replace Price addition of $30 per DC Voltage Suffix DC Voltage Suffix
the (*) with the suffix from Coil Table. relay. For 32 & 64 volt 12 12 095 095
coils , use coil suffix 32 24 24 120 120
Overlapping contacts are available in the
or 64. $150 set up
same contact block at $108 per pair 48 48 240 240
charge for 5 or less
Enclosures supplied separately units.

Discount Schedule JC55 K13


PMT - Relays DC Time Delay Relays

DC Pneumatic Time Delay Relays - Type PMT Bulletin 7314


(.2 seconds to 3minutes)
Bulletin 7314 D-C Time Delay Relays are Universal poles, with two electrically isolated
identical in construction to the Bulletin contacts per pole-one normally open and one
7313 Timing Relays except for the use normally closed-are also used. These timing
of a conventional 2 lead operating coil relays are available for either On Delay or Off
rather than a tapped (3-lead) coil. They Delay operation in three basic models: (1) with
feature the same accurate piston-type timed pole; (2) with one timed and one
timing head as used on all other timing instantaneous pole or (3) with two timed poles.
relays in the PM family.

Timing range adjustable from 0.2 seconds to 3 minutes Accuracy + 10%

"On-Delay" Type Contacts Open Type Relays


Operation Oper'n No. of Time Delay Instan.Aux. Universal
Plus Univ. Pole Without Dial
Delay Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price
On
Delay 1 1 714UP
Off 1 $726.
Delay 1 1 714UPD
On
Delay 1 1 1 1 714UPA
Off 2 792.
Delay 1 1 1 1 714UPDA
On
Delay 2 2 714UPE
Off 2 924.
Delay 2 2 714UPDE

Coil Burden 17.2 watts


"Off-Delay" Contact Ratings - 10 Amps Continuous
Operation
D-C Applications
Amperes Interrupting Rating
K
Note: Resistive Load
1
On Delay - timed interval occurs between energization of the coil and Non-Inductive Inductive Load
actuation of timed contact. Volts N.O. N.C. N.O. or N.C.
Off Delay - timed interval occurs betwen de-engerization of the coil and
actuation of timed contact. 64 or less 10 10 2.2
Field conversion of relays from On Delay to Off Delay operation, or vice- 120 8 6 1.1
versa, is not recommended because a special technique is required. 240 2 1 .55
2
Each universal pole consists of 1 N.O. & 1 N.C. independent isolated
contacts suitable for 600 volts at opposite polarity, a-c or d-c. A-C Applications
3
Letter T on relay sketches indicated location of time delay poles. Letter Volts Make Break
I on relay sketches indicates location of instaneous poles. Dotted lines 110 60 6
indicate where universal poles may be added. 220 30 3
440 15 1.5
550 12 1.2

0
2
3
Ordering Information Coil Table DC Voltage
Use complete catalog number. Replace Price addition of $30 DC Voltage Suffix
the (*) with the suffix from Coil Table. per relay. For 95 120 120
Overlapping contacts are available in the volt coils , use coil 240 240
same contact block at $108 per pair suffix 95. $150 set
For timer with dial, specify "with dial." up charge for 5 or
Add (each) $60. less units

K14 Discount Schedule JC55


DC Time Delay Relays Relays - PMT
DC Pneumatic Time Delay Relays - Type PMT Bulletin 7313
(.2 seconds to 3minutes)
Bulletin 7313, Type PMT, D-C Time Delay contact in a universal pole to economize the
Relays are identical in construction and size coil (see sketches below. However, the N.O.
to the A-C timing relays except they contact in that pole remains available for
incorporate a tapped (3-lead) d-c operating customer use. Timing relays with conven-
coil and, hence, require the use of one N.C. tional 2-lead coils can also be supplied. Refer
to Bulletin 7314-PMT.
Timing Range Adjustable From 0.2 Second to 3 Minutes - Accuracy + 10%
Contacts Open Type Relays
No. of Time Delay Instan.Aux. Universal
Oper'ng Univ. Pole Without Dial
Mode Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price
On
Delay 1 1 None None 713UP-DC *
Off 1 $726.
Delay 1 1 None None 713UPD-DC *
On
Delay 1 1 1 1 713UPA-DC *
Off 792.
Delay 1 1 1 1 713UPDA-DC *
2
On
Delay 2 2 None None 713UPE-DC *
Off 924.
Delay 2 2 None None 713UPDE-DC *
On
Delay 1 1 2 2 713UPB-DC *
Off 858.
Delay 1 1 2 2 713UPDB-DC *
3
On
Delay 2 2 1 1 713UPF-DC *
Off 990. Coil Burden: Inrush 350 Watts
Delay 2 2 1 1 713UPDF-DC * Sealed 5 Watts

Contact Ratings - 10 Amps Continuous Functioning of Economizing Interlock Pole On

D-C Applications
D-C Relays
X - Economizing electrical interlock (used in coil circuit) K
Amperes Interrupting Rating is one contact of standard universal pole.
Resistive Load Typical connection of three terminal coil is shown.
Non-Inductive Inductive Load
Volts N.O. N.C. N.O. or N.C.
"ON-DELAY" "OFF-DELAY"
64 or less 10 10 2.2 (Time Delay after denergization)
(Time Delay after energization)
120 8 6 1.1
240 2 1 .55

A-C Applications
Volts Make Break
110 60 6
220 30 3
440 15 1.5
550 12 1.2
0
2
3 Ordering Information Coil Table DC Voltage
Use complete catalog number. Replace Price addition of $30 DC Voltage Suffix DC Voltage Suffix
the (*) with the suffix from Coil Table. per relay. For 32 & 12 12 95 095
Overlapping contacts are available in the 64 volt coils , use 24 24 120 120
same contact block at $108 per pair coil suffix 32 or 64. 48 48 240 240
For timer with dial, specify "with dial" $150 set up charge
Add (each) $60. for 5 or less units

Discount Schedule JC55 K15


PM - Relays Engineering Data

FRONT Hm
DC Contact Rating - P600
Amperes Volt Amperes 2 Continuous
H
Volts Make Break Make Break Amperes
125 1.1 1.1 138 138 5

250 0.55 0.55 138 138 5


Wm
W D 600 0.20 0.20 1382 1382 5

2
300 Volts or Less

All relays require a minimum of 7


/8 in. clearance below magnet for coil change.
A horizontal space of 1
/8 in. between relays is recommended.

Mounting Holes For #10 Screws

Relay Open Relay


Type Cat. Number H W D Hm Wm
K

PM-DC 4U2,4U3,4U4 6 1/8 3 3 1/4 4 1/2 2


4U6,4U8 6 1/8 4 1/2 3 1/4 4 1/2 2

PML-DC 5UHD2 5 5/16 3 3 5/8 4 1/2 2


5UHD3, 5UHD4 5 5/16 4 1/2 3 5/8 4 1/2 2

4
3
0
PMT-DC 714UP 6 1/8 3 3 1/8 4 1/2 2 1/2
713UP-DC 1,2-Pole 5 1/2 3 3 3/8 4 1/2 2
713UP-DC 3 Pole 5 1/2 3 3/4 3 3/8 4 1/2 2
713UP-DC 4 Pole 5 1/2 4 1/2 3 3/8 4 1/2 2

K16
Coil Data Relays - PM
Standard catalog listed AC relays ordered basic and latch relays except the Slim Jim, first factor. As shown in Table 1, one coil for
will have the proper coils as determined by determine the mechanical load on the magnet each voltage and frequency will operate all
the voltage and frequency suffix to the simply by totalling the load represented by the pole combinations.
catalog number. individual components operated by the magnet,
Changing the circuit arrangement on a relay using the mechanical load factors shown below.
also changes the mechanical load on the Select the proper coil from Table 1.
magnet and may require a change of When selecting the proper coil for Slim Jim
operating coil to assure proper operation. Relays and Time Delay Relays, it is not
the information on this page will enable you necessary to determine the mechanical load
to select the correct operating coil for any
circuit arrangement required. Voltage- Mechanical Load Factors:
ampere requirements are provided to help in Convertible Pole - Normally Open ................................................................... 10
designing your panels. Convertible Pole - Normally Closed ................................................................. 12
To select the proper operating coil for all Double Contact Pole - Universal or Duplex ..................................................... 36
Latch Mechanism ............................................................................................. 20
Example:
For Example: A relay with 1 N.O. and 9 N.C.
Table 1 indicates that the proper coil convertible poles and a latch
number for 110 volts, 60 hertz application mechanism will have a mechanical
is TB113-61, since the load factor of 168
load factor as follows:
falls within the Mechanical Load Range of
1 N.O. Convertible Pole .............................................................................. 10
145 to 192.
9 N.C. Convertible Poles .......................................................................... 108
Accumulation Factor 1 ............................................................................................................... 30
1 Latch Mechanism ..................................................................................... 20
Total Mechanical Load Factor .................................................................. 168

Coil Application Tables - Type PM Relay Family Table 1


Basic And Latch Relays Time Delay
Relays
Slim Jim Trip Coil
Relays on Latch
Mechanical Load Range All Pole Relays, All Class A
(Does Not Apply To Slim Jim Relays) Combi- Pole Com- All Pole
AC Volts Hertz 20-72 73-144 145-192 193-240 nations binations Combinations
Coil Catalog Numbers - Bulletin 7303 & 7305 PM & PML
24
110-120
60
60
TB113-36 TB113-37 TB113-60 --- TB139-10 TB127-14 TB135-16 K
110 50 TB113-1 TB113-3 TB113-61 TB130-13 TB139-1 TB127-20 TB135-1
110 25 TB113-20 TB113-20 --- --- --- TB127-23 TB135-14
220-240 60
TB113-4 TB113-6 TB113-62 TB130-14 TB139-2 TB127-21 TB135-2
220 50
220 25 TB113-8 TB113-8 --- --- --- TB127-5 TB135-15
60 TB113-65 TB113-64 TB113-63 TB130-3 TB139-3 TB127-3 TB135-3
380 50 TB113-7 TB113-28 TB113-64 TB130-9 TB139-4 TB127-4 TB135-9
25 TB113-22 TB113-22 --- --- --- TB127-12 ---
440-480 60 TB113-7 TB113-9 TB113-64 TB130-9 TB139-4 TB127-11 TB135-4
440 50
440 25 TB113-33 TB11-33 --- --- --- --- TB135-17
550-600 60
TB113-16 TB113-11 TB113-66 TB130-6 TB139-6 TB127-6 TB135-6
550 50
550 25 TB113-34 TB113-34 --- --- --- --- ---
Volt -Amperes
4
3 INRUSH 67 108 141 161 61 16 215
0 60
SEALED 23 36 47 53 16 8 35
INRUSH 51 93 124 180 51 Refer to 180
SEALED 50 18 33 45 49 13 Sales Office 30
INRUSH 39 50 --- --- --- Refer to 70
SEALED 15 22 --- --- --- Sales Office 15

1
For relays with 9 or more normally closed convertible poles, an accumulation factor of 30 must be added to to the total
mechanical load factor for the relay

K17
447 Relays Control Relays
Description
Series 447 relays are designed for AC and DC circuits where high reliability, versatility of contact and operating coil combinations,
compact size, and high speed operation are required. The 447 relays are available up to 8 convertible poles, current ratings to
30 amps AC and 20 amps DC.

Unit Poles - AC Load (Table 2)


460VAC Max
Components (Table 1)
Description Cat. No. Price
Base ...........and Coil Voltage Cat. No. Price
10A, N.O. 447-9046 $44.
4 Pole Base- 120 VAC Coil 1 447-9402-11 $ 144. 10A, N.C. 447-9047 44.
208 VAC Coil 447-9402-21 144. 20A, N.O. 447-9048 54.
240 VAC Coil 447-9402-21 144. 20A, N.C. 447-9049 54.
480 VAC Coil 447-9402-31 144. 30A 3 N.O. 447-9071 66.
8 Pole Base- 120 VAC Coil 2 447-9801-11 210. 4-Pole Base 30A 3 N.C. 447-9072 66.
208 VAC Coil 447-9801-21 210. 3
240 VAC Coil 447-9801-21 210. Tungsten or Resistive Loads, 277 VAC Max.

4 Pole Base- 115 VDC Coil 1 447-9405.13 276. Unit Poles - DC Load (Table 3)
230 VDC Coil 447-9405-23 276. 250VDC Max
8 Pole Base- 115 VDC Coil 2 447-9805-13 380. Description 4 Cat. No. Price
230 VDC Coil 447-9805-23 380.
20A, N.O. 1-Blowout 447-9019 $66.
1
Heavy Duty Coil, Suitable For Up To 4 Circuits 20A, N.O. 2-Blowout 447-9020 72.
2
Heavy Duty Coil, Suitable For Up To 8 Circuits 20A, N.C. 1-Blowout 447-9021 66.
8-Pole Base 20A, N.C. 2-Blowout 447-9022 72.
Note: Other AC and DC coil voltages are 4
All DC contacts require a "Blowout
available. Please contact factory.
Mechanism" to extinguish the "arc" during
contact opening. See Rule "B" below.
Rules to Select and Install Contacts
A. When installing “AC” or “DC” contacts you should balance the mechanical load on the coil magnet preferably by placing
the contacts together in the center and working your way out.
- For a 4-pole contact install the contacts in sequence per the diagram listed below.

3 2 1 4 K
- For an 8-pole contact install the contacts per this diagram.
5 3 2 1 4 6
8 7

B. When installing DC contacts, using the contact sequence above, the last contact on the left must have two blowouts.
All others will have only one.

Example: If you have four contacts on the 4-pole base (table 1), number 3 must have two blowouts. If you have only two
contacts, then number 2 must have two blowouts.

If you have six contacts on the 8-pole base (table 1), number 5 must have two blowouts.

Contacts seven and eight on the 8-pole base must have two blowouts.

2
5
5

Ordering Information
Select and Price Base and Power Plant and Unit Poles Separately. 1 - 447-9402-11 $ 144.
Example: 120 VAC 4 Pole relay with 2 N.O., 2 N.C., 10 Amp Poles. 2 - 447-9046 88.
2 - 447-9047 88.
Dimensions: See Section L Page 6. $320.

K18 Discount Schedule JC55


Index MEKontrol
Photoelectric Sensors & Controls

MEK 90 : User Selectable ............................................................. M2

Accessories .................................................................................... M4

Operating Mode Index Photoelectric Control

Operation Mode Description Catalog No. Range Page

Retroreflective User Selectable MEK90-LU __ 18 ft. M2

User Selectable MEK90-U __ 18 ft. M2

Polarized Retroreflective High Performance MEK90-P __ 27 ft. M2

Thru-Beam User Selectable MEK90-LU __ 200 ft. M2

User Selectable MEK90-U __ 200 ft. M2

Diffuse User Selectable MEK90-LU __ 78 in. M2

User Selectable MEK90-U __ 78 in. M2

Fiber-optic Controls User Selectable * MEK90-(L)U __ M2

M
M

MEK 90 Universal and High Performance Series MEK 90 Dedicated Controls

0
1
6

M1
M1
MEK90 Photoelectric Control
MEK 90 Universal and High
Performance Series
User Programmable or Dedicated Controls:
Thru-Beam, Retroreflective, Diffuse Reflective,
Convergent, Fiberoptic Thru-Beam, Fiberoptic Diffuse
Two Built-In Timers
Plug-In control may be replaced without rewiring
User configurable as a Retro, Diffuse, Light Source or
Light Receiver (Thru-Beam)
Two timers included: On Delay, Off Delay, One Shot or
Delayed One Shot may be selected or combined
Two selectable timing ranges: 0-1.5 sec. and 1-15 sec.
Large capacity 6A SPDT Relays, AC FET outputs and
NPN Open Collector outputs are available
Wide range of supply voltages
Optional lens kits for conversion to Convergent Beam or
Fiberoptic in the field
Dedicated factory assembled controls: Polarized Retro,
Fiber Optic, and Dedicated Light Source (Emitter)
Housing environmental integrity is 1, 4, 4X, 12, and 13
Mounting Brackets on page M24
Selection Chart
Universal Control: Provide Retro, Diffuse and Thru-Beam
Output Supply voltage Max. Load Range (Using standard test targets) Catalog No. Price
Relay 102-132 VAC 6A / 240 VAC (res) Retro: 18 ft. Diffuse: 78 in. T-B: 200 ft. MEK90-LUAR 1,3 $ 348.00
Relay 105-264 VAC 6A / 240 VAC (res) Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UAR 348.00
NPN 10-36 VDC 200 mA / 30 VDC Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UDC 348.00
Relay 10-36 VDC 6A / 120 VAC Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UDR 348.00

Dedicated High Performance Series: Polarized Retroreflective


Relay 105-264 VAC 6A / 240 VAC (res) High Gain: 27 ft. Low Gain: 10 ft. MEK90-PAR 4 $ 366.00
NPN 10-30 VDC 200 mA / 30 VDC High Gain: 27 ft. Low Gain: 10 ft. MEK90-PDC 4 366.00
Relay 10-30 VDC 6A / 240 VAC High Gain: 27 ft. Low Gain: 10 ft. MEK90-PDR 4 366.00

Visual Relay Petro Reflective


Relay 102-132 VAC, 50/60 HZ 6A / 240 VAC (res) 6 ft. - 35 ft. MEK90-VRAR $ 366.00 M
204-264VAC, 50/60 HZ

Specifications Specifications
Output Response Time
Power Consumption 2VA, 50mA
Relay: SPDT 6A 240VAC (resistive) 28 \VDC <10ms. ON, <8ms. OFF
Materials (Housing) Corrosion Resistant,
FET: SPNO Solid State AC Output 1A @ 250 C, <13ms. ON, 13ms. OFF Fire Retardant ABS
0.5A @ 600 C (<10uA OFF State Leakage) (Lens) Polycarbonate 0
Open Collector: NPN (sinking) 200 mA 30VDC <5ms. ON, <5ms. OFF 1
Environmental Ratings NEMA 3,4,4X,12, and 13 6
Temperature Range -400 to 1580 F -400 to 700 C
Approvals U.L. Recognized C.S.A.

1 90% White Card.


2 Reflective Targets refer to page M4.

M2 Discount Schedule JC90


M1
Performance Data MEK90
Mode Selection Switch Settings OFF ON
Example: Proximity Mode
Operating Mode Switch Positions Delay 3 A
A B C
0-15 Sec. Timing Range B
Retroreflective OFF OFF ON
Light Operate C
3. The actual delay mode One Shot Delay
Thru-Beam Source OFF OFF ON depends on where timing
adjustments T1 and T2 are
Thru-Beam Receiver (Standard) OFF ON ON set. When both are set to
0-15 Sec. 0-1.5 Sec.
Thru-Beam Receiver (Long Range) ON ON ON minimum (0) the unit operates
in the NO DELAY Mode.
Light Dark
Proximity ON OFF ON
Converging Beam Proximity 1 ON OFF ON

2
Fiberoptic (All Modes) ON OFF ON

1
Refer to page M58 for accessory Converging Bean Lens Kits.
2
Refer to page M58 for accessory Fiberoptic Adaptors: Refer to
page M33 for MEK901 Glass Fiberoptic Light Guides.

0
1
6

M1 M3
Photoelectric Control Accessories
Plastic Corner Cube Reflectors
Catalog No. Dimensions Range Use With:
K-3567 3 in. dia. Long Any Retroreflective, Polarized or Reflective Fiberoptic control
K-3568 1.5 in. dia. Middle Any Retroreflective, Polarized or Reflective Fiberoptic control
K-4305 0.625 in dia. Short Any Retroreflective, Polarized or Reflective Fiberoptic control

Retroreflective Targets
Description Catalog No. Price
Corner Cube Reflector 3" DIA. K-3567 $ 14.
Corner Cube Reflector 1.5" DIA. K-3568 8.
Corner Cube Reflector .625" DIA. K-4305 8.

Control Guard For MEK90/91


3"
MEK901-RT230 3-1/2"
Note:
Provides effective protection from
physical damage. PHOTO CONTROL
GUARD
Description Catalog No. Price MEK90/91 8"
CONTROL
Parallel Mount for MEk 90/91 MEK901-RT100 $ 16.
Universal Mount for MEK 90/91 MEK901-RT150 34.
Right Angle Mount for MEK 90/91 MEK901-RT200 16.
Right Angle/360 Deg. Mount for MEK 90/91 MEK901-RT210 16.
2"
Flex-Mount for Mek 90/91 MEK901-RT220 58.
MEK 90/91 Guard MEK901-RT230 76.
For MEK 55 Series MEK55-RT123 $ 24.
USES MEK901-RT210
MOUNTING BRACKET

Mounting Brackets For MEK90


MEK901-RT210
M

0
#10 INTERNAL 1
TOOTH 6
LOCKWASHER
(2 INCL.)

#10-32 SLOTTED
HEX WASHER
HEAD SCREWS
(2 INCL.)

M4 Discount Schedule JC90


M1
Index Replacement Coils
Description Coil Prefix Page Number
PM Magnetic Relays, DC Operated TB137- ........................................ 3
PM, PMA, PMF, PML, PMAL Magnetic Relays TB113- ........................................ 2
PMA, PMF, PMAL Magnetic Relays TB130- ........................................ 2
PMS Magnetic Relays TB139- ........................................ 3
PML, PMAL Magnetic Latch Relays TB127- ........................................ 2
PMT Pneumatic Timing Relays, Class A, Folio 2 TB135- ........................................ 3
PMT Pneumatic Timing Relays, Class A, TB130- ........................................ 2
(non-Folio 2) and Class B
PMT Pneumatic Timing Relays, DC Operated TB140- ........................................ 3
(3 Lead)
PMT Pneumatic Timing Relays, DC Operated TB137- ........................................ 3
(2 Lead)
TM-00-2 Magnetic Magnetic TB159- ........................................ 4
Starters & Contactors
HP & HPF-00-2 & 1 Magnetic Starters & Contactors TB174- ........................................ 3
TM-3 & TM-4 Magnetic Starters & Contactors TB162- ........................................ 4
TM-5 Magnetic Starters & Contactors TB161- ........................................ 4
TM-6 Magnetic Starters & Contactors TB163- ........................................ 4
U-5 Magnetic Starters & Contactors 335L- .......................................... 4
DP-3 Definite Purpose Contactors, DPS Starters TB175- ........................................ 3
447 Magnetic Relays, DC Operated TB137- ........................................ 3
447 Magnetic Relays, AC Operated TB113- ........................................ 2
LC20, LC30, Lighting Contactors TB113- ........................................ 2
LCL20, LCL30, Lighting Contactors TB113 (Main), TB127 (Trip) ........ 2
5000A, Size 00-1 Contactor & Starters 344L ........................................... 5
5000A, Size 2 Contactor & Starters 343L ........................................... 5
5000A, Size 3 Contactor & Starters 319L ........................................... 5
5000-, Size 4 Contactor & Starters 320L ........................................... 5
5000-, Size 5 Contactor & Starters 335L ........................................... 5
5000-, Size 2 Contactor & Starters 319L ........................................... 5
5000-, Size 3 Contactor & Starters 320L ........................................... 5
7000, 7001 DC Contactor, AC Operation 344L ........................................... 5
5DP1, 5DP2, 5DP3A DC Contactors AC Operated 319L ........................................... 5
N
5DP7 DC Contactors AC Operation 343L ........................................... 5
0
2 5DP3-, 5DP4, 5DP9 DC Contactors AC Operation 320L ........................................... 5
6
5DP5, 5DP8 DC Contactors AC Operation 335L ........................................... 5
5DP6 DC Contactors AC & DC Operation 347L ........................................... 5

M1
N1
Replacement Coils Numerical Coil Data
Description Coil Volts Hertz Price
TB127-1 110 60 $69.00
For Use With Series: TB127-2 220 60 69.00
Description Coil Volts Hertz Load Factor Price LCL20, LCL30, TB127-2 115-230 DC 69.00
TB113-1 110-120 60 20-72 $99.00 PML, PMAL TB127-2 180 DC 69.00
TB127-3 380 60 115.00
For Use With Series: TB113-3 110-120 60 73-144 99.00 (Trip Coil)
TB127-4 380 50 115.00
447, LC20, LC30, TB113-3 110-120 50 145-192 99.00
TB113-4 220-240 60 20-72 99.00 TB127-4 440 60 115.00
PM, PMA, PMF, TB127-5 220-240 25 276.00
TB113.4 277 60 73-144 99.00
PMAL TB113-6 277 60 145-192 99.00 TB127-5 440 50 276.00
TB113-6 220-240 60 73-144 99.00 TB127-5 550 60 276.00
TB113-6 220-240 50 145-192 99.00 TB127-6 440-480 50 276.00
TB113-7 380 50 20-72 99.00 TB127-6 550-600 60 276.00
TB113-7 440-480 60 20-72 99.00 TB127-7 110 50 276.00
TB113-7 550 60 73-144 99.00 TB127-8 110 25 276.00
TB113-7 550 50 145-192 99.00 TB127-8 220 50 276.00
TB113-8 220-240 25 20-96 99.00 TB127-9 550 50 276.00
TB113-9 440-480 60 73-144 99.00 TB127-10 550-600 50 276.00
TB113-9 440-480 50 145-192 99.00 TB127-11 220 25 115.00
TB113-10 550 60 20-72 99.00 TB127-11 440-480 60 115.00
TB113-11 600 60 73-144 99.00 TB127-12 380 25 276.00
TB113-11 600 50 145-192 99.00 TB127-13 440 25 276.00
TB113-13 440-480 50 73.144 99.00 TB127-14 24 60 69.00
TB113-15 277 60 20-72 99.00 TB127-15 12 60 69.00
TB113-16 600 60 20-72 99.00 TB127-19 110 40 276.00
TB113-18 110-120 50 20-72 99.00 TB127-20 110-120 60 69.00
TB113-19 110-120 50 73-144 99.00 TB127-21 220-240 60 69.00
TB113-20 110-120 25 20-96 99.00 TB127-22 110-120 50 276.00
TB113-20 220-240 50 73-144 99.00 TB127-23 110-120 25 69.00
TB113-21 440-480 50 20-72 99.00 TB127-23 220-240 50 69.00
TB113-21 600 50 73-144 99.00
TB113-22 550 40 20-72 99.00
TB113-22 380 25 20-96 99.00 Load
TB113-23 550 50 73-144 99.00 Description Coil Volts Hertz Factor Price
TB113-24 600 50 20-72 99.00 For Use TB130-1 110 60 230.00
TB113-28 380 50 73-144 99.00 With Series: TB130-2 208-220 60 230.00
TB113-32 600 25 20-96 99.00 TB130-3 380 60 230.00
PMT *, PMA,
TB113-33 440-480 25 20-96 99.00 TB130-3 380 60 193-240 230.00
TB113-34 550 25 20-96 99.00 PMF, PMAL
TB130-4 400 60 230.00
TB113-36 24 60 20-72 99.00 TB130-5 550 60 230.00
TB113-37 24 60 73-144 99.00 TB130-5 440 50 230.00
TB113-39 12 60 20-72 99.00 TB130-5 440-480 50 193-240 230.00
TB113-40 12 60 73-144 99.00 TB130-5 550 60 193-240 230.00
TB113-47 48 60 20-72 99.00 TB130-6 600 60 230.00
TB113-48 48 60 73-144 99.00 TB130-6 600 60 193-240 230.00
TB113-51 6 60 20-72 99.00 TB130-7 110 50 230.00
TB113-51 8 60 145-192 99.00 TB130-7 110-120 50 193-240 230.00
TB113-53 8 60 20-72 99.00 TB130-8 208-220 50 230.00
TB113-55 8 60 73-144 99.00 TB130-8 220-240 50 193-240 230.00
TB113-60 24 60 145-192 99.00 TB130-9 380 50 230.00
TB113-61 110-120 60 145-192 99.00 TB130-9 380 50 193-240 230.00
TB113-62 220-240 60 145-192 99.00 TB130-9 440-480 60 193-240 230.00
TB113-63 220-240 50 20-72 99.00
TB113-63
TB113-64
380
380
60
60
145-192
73-144
99.00
99.00
TB130-9
TB130-10
480
550
60
50
230.00
230.00 N
TB130-10 550 50 193-240 230.00
TB113-64 380 50 145-192 99.00 TB130-11 600 50 230.00
TB113-64 440-480 60 145-192 99.00 TB130-11 600 50 193-240 230.00 0
TB113-65 380 60 20-72 99.00 TB130-12 24 60 230.00
2
6
TB113-65 550 60 145-192 99.00 TB130-13 120 60 230.00
TB113-66 600 60 145-192 99.00 TB130-13 110-120 60 193-240 230.00
TB113-71 48 60 145-192 99.00 TB130-14 240 60 230.00
TB113-76 12 60 145-192 99.00 TB130-14 220-240 60 193-240 230.00
TB113-76 6 60 73-144 99.00 TB130-17 42 50 230.00
TB113-77 6 60 145-192 99.00
* NOTE:
TB130 coils are used on Bul. 7313 Timing Relays not marked
"Folio2". This includes original Class A timers and all Class B
timers. See TB135 coils for Class A, Folio 2 timers.

N2 Discount ScheduleM1
JC80
Numerical Coil Data Replacement Coils
Description Coil Volts Hertz Price Description Coil Volts Price
TB135-1 110 60 $108.00 TB140-1 115-120 DC $221.00
For Use With Series: TB135-2 208-220 60 108.00 For Use With Series: TB140-2 230-250 DC 281.00
PMT * TB135-3 380 60 108.00 PMT (DC) TB140-3 260 DC 281.00
TB135-4 440 60 108.00 Folio 2 TB140-4 12 DC 432.00
Discount TB135-5 550 60 108.00 TB140-5 24 DC 432.00
TB135-6 600 60 108.00
Discount TB140-6 72 DC 432.00
Schedule Schedule
TB135-7 110 50 108.00 TB140-7 48 DC 432.00
JC80 JC80 TB140-8 32 DC 432.00
TB135-8 208-220 50 108.00
TB135-9 380 50 108.00
TB135-10 440 50 108.00
TB135-11 550 50 108.00
TB135-12 600 50 108.00
TB135-13 120 60 108.00
TB135-14 110 25 108.00
240 60 108.00
TB135-15 220 25 108.00
480 60 108.00 Substitute TB135-4 for 460V 60 Hz.
TB135-16 24 60 108.00
TB135-17 440 25 108.00
TB135-18 110 40 108.00
TB135-19 12 60 108.00
TB135-20 120 50 108.00
TB135-21 240 50 108.00
TB135-22 480 50 108.00
TB135-23 12 50 108.00
TB135-24 24 50 108.00
Description Coil Volts Hertz Poles Price
TB135-25 208 60 108.00
TB170-1 120 50/60 2, 3, 4 $48.00
* NOTE: For Use TB170-2 208-240 50/60 2, 3, 4 48.00
TB135 coils are used on Bul. 7313 Timing Relays marked "Folio With Series: TB170-3 24 50/60 2, 3, 4 48.00
2". See TB130 coils for timers not marked "Folio 2". DP TB170-4 277 50/60 2, 3, 4 48.00
TB170-5 480 50/60 2, 3, 4 48.00
(Size DP-3)
Description Coil Volts Price TB170-6 600 50/60 2, 3, 4 48.00
Discount
TB137-1 120 DC $248.00 Schedule
For Use With Series: TB137-2 240 DC 248.00 JC53
PM, 447, TB137-3 180 DC 248.00
PMT TB137-4 90 DC 248.00
TB137-5 64 DC 248.00
(DC 2 Lead)
TB137-6 48 DC 248.00
Discount TB137-7 32 DC 248.00 Description Coil Volts Hertz Poles Price
Schedule TB137-8 24 DC 248.00
For Use TB174-1 120 50/60 2, 3 $97.00
JC80 TB137-9 12 DC 248.00
With Series: TB174-2 208-240 50/60 2, 3 97.00
TB137-10 6 DC 248.00
HP/HPF TB174-3 24 50/60 2, 3 97.00
TB137-11 300 DC 248.00
(Size 00-2) TB174-4 277 50/60 2, 3 97.00
TB137-12 120 DC 248.00
Timers Only TB174-5 480 50/60 2, 3 97.00
TB137-13 240 DC 248.00 Discount TB174-6 600 50/60 2, 3 97.00
TB137-14 95 DC 248.00 Schedule TB174-7 380 50/60 2, 3 97.00
JC53
Description Coil Volts Hertz Price
TB139-1 110-120 60 $99.00
For Use With Series: TB139-2
PMS TB139-3
220-240
380
60
60
99.00
99.00 N
TB139-4 440-480 60 99.00
Discount TB139-4 380 50 99.00
0 TB139-6 550-600 60 99.00
2 Schedule
6 TB139-7 64 60 99.00
JC80 TB139-8 48 60 99.00
TB139-9 32 60 99.00
TB139-10 24 60 99.00
TB139-11 12 60 99.00
TB139-12 6 60 99.00
TB139-13 110-120 50 99.00
TB139-14 220-240 50 99.00

Discount Schedule JC53 & 80 M1


N3
Numerical Coil Data Replacement Coils
Description Coil Volts Hertz Price Description Coil Volts Hertz Poles Price
TB161-1 110-120 60 $483.00 For Use 335L1 110-120 60 2, 3 $322.00
For Use TB161-1 110 50 483.00 With: U5 335L1 110 50 2, 3 322.00
TB161-2 220-240 60 483.00 (U Series 335L2 220-240 60 2, 3 322.00
With:
TB161-2 220 50 483.00 Only) 335L3 440-480 60 2, 3 322.00
TM -5 TB161-3 440-480 60 483.00 335L3 440 50 2, 3 322.00
(TM Series TB161-3 440 50 483.00 Discount 335L4 550-600 60 2, 3 322.00
Only) TB161-4 550-600 60 483.00 Schedule 335L4 550 50 2, 3 322.00
TB161-4 550 50 483.00 JC27 335L7 200-208 60 2, 3 322.00
TB161-5 200-208 60 483.00
Discount
TB161-6 110 25 483.00
Schedule TB161-7 220 25 483.00
JC80 TB161-8 440 25 483.00 NOTE:
TB161-9 550 25 483.00
TB161-10 380 50 483.00 These size 5's are not interchangeable

Description Coil Volts Hertz Size Price Description Coil Volts Hertz Poles Price
TB162-1 110-120 60 4 $248.00 TB159-1 110-120 60 2, 3, 4 $124.00
For Use TB162-1 110 50 4 248.00 For Use TB159-1 110 50 2, 3, 4 124.00
TB162-2 220-240 60 4 248.00 TB159-2 220-240 60 2, 3, 4 124.00
With Series: With Series:
TB162-2 220 50 4 248.00 TB159-2 220 50 2, 3, 4 124.00
TM -3,4 TB162-3 440-480 60 4 248.00
TM (Size 00,
TB159-3 440-480 60 2, 3, 4 124.00
TB162-3 440 50 4 248.00 0, 1, 2)
TB159-3 440 50 2, 3, 4 124.00
TB162-4 550-600 60 4 248.00 TB159-4 550-600 60 2, 3, 4 124.00
TB162-4 550 50 4 248.00
Discount
TB159-4 550 50 2, 3, 4 124.00
TB162-5 110 25 4 248.00 Schedule
TB159-5 110 25 2, 3, 4 124.00
TB162-6 440-480 25 3 248.00 JC80 TB159-6 220 25 2, 3, 4 124.00
Discount TB162-7 110-120 60 3 207.00 TB159-7 400 25 2, 3, 4 124.00
TB162-7 110 50 3 207.00 TB159-8 550 25 2, 3, 4 124.00
Schedule
TB162-8 220-240 60 3 207.00 TB159-9 24 60 2, 3, 4 124.00
JC80 TB162-8 220 50 3 207.00 TB159-10 200-208 60 2, 3, 4 124.00
TB162-9 440-480 60 3 207.00 TB159-11 380 50 2, 3, 4 124.00
TB162-9 440 50 3 207.00 TB159-13 277 60 2, 3, 4 124.00
TB162-10 550-600 60 3 207.00
TB162-10 550 50 3 207.00
TB162-11 440-480 60 4 207.00
TB162-12 24 60 3 207.00
TB162-13 277 60 3 207.00
TB162-14 200-208 60 3 207.00
TB162-14 110-120 25 3 207.00
TB162-15 380 50 3 207.00
TB162-15 220-240 25 3 248.00
TB162-16 200-208 60 4 248.00
TB162-16 110-120 25 4 248.00
TB162-17 380 50 4 248.00
TB162-17 220-240 25 4 248.00
TB162-19 110 60 4 248.00

Description Coil Volts Hertz Price N


TB163-1 110-120 60 $573.00
For Use TB163-1 110 50 573.00 0
With Series: TB163-2 220-240 60 573.00 2
TM (Size 6) TB163-2 220 50 573.00 6
TB163-3 440-480 60 573.00
TB163-3 440 50 573.00
Discount TB163-4 550-600 60 573.00
Schedule TB163-4 550 50 573.00
TB163-5 200-208 60 573.00
JC80 TB163-6 380 50 573.00
TB163-7 277 30 573.00

N4 Discount Schedule JC27M1


& 80
Numerical Coil Data Replacement Coils

Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 344L1 110-120 60 $53.00 For Use 335L1 110-120 60 $322.00
With Series: 344L1 110 50 53.00 With Series: 335L1 110 50 322.00
5000A*, 7000, 344L5 220-240 60 53.00 5000-*, 5DP5, 335L2 220-240 60 322.00
344L3 440-480 60 53.00 5DP8 335L2 220 50 322.00
7001, 8000B
344L3 440 50 53.00 335L3 440-480 60 322.00
(Size 00, 0, 1, (Size 5
344L4 550-600 60 53.00 335L3 440 50 322.00
10/40 Amp, 344L4 550 50 53.00
360,535 Amp) 335L4 550-600 60 322.00
40 Amp) 344L6 24 60 53.00 335L7 208 60 322.00
344L2 200-208 60 53.00

Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 343L1 110-120 60 $76.00 For Use 347L1 110-120 60 $1656.
With Series: 343L2 220-240 60 76.00 With Series: 347L4 220-240 60 2185.
5000A*,5DP7, 343L2 220 50 76.00 5DP6 347L2 440-480 60 2185.
8000B 343L3 440-480 60 76.00
700 Amp
343L3 440 50 76.00
(Size 2
343L4 550-600 60 76.00
75 Amp) 343L4 550 50 76.00
343L5 208 60 76.00 NOTE:
For further information on Power Pack Kits
(AC Coil) see page J6

Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 319L1 110-120 60 $110.00 For Use 320L1 110-120 60 $156.00
With Series:
5000A*,5DP1,
319L1
319L2
110
220-240
50
60
110.00
110.00
With Series:
5000-*,
320L1
320L2
110
220-240
50
60
156.00
156.00
N
319L3 440-480 60 110.00 5DP3-*, 320L3 440-480 60 156.00
5DP2, 8000B,
319L3 440 50 110.00 320L3 440 50 156.00
0 5DP3A* 5DP4, 5DP9,
2 319L4 550-600 60 110.00 320L4 550-600 60 156.00
6 (Size 3 319L4 550 50 110.00
8000B 320L4 550 50 156.00
30, 56, 319L5 24 60 110.00 (Size 4 110*, 320L2 200-208 60 156.00
110 * Amp) 319L2 200-208 60 110.00 180,260 Amp)

* NOTE:
Series 5DP3A 110 Amp., and 5DP3- 110 Amp., are not interchangeable
Series 5000A and 5000- are not interchangeable

Discount Schedule JC27 M1


N5
Bulletin/Series Index Joslyn Clark Controls
Bulletin Page Description Bulletin Page Description

Pilot Devices-Pushbutton Controls AC Reduced Voltage Starters


100T D1 30MM Heavy Duty 6082TM B26 Type TM Autotransformer Non Combo
STAK-LITE D22 Status Indicator 6082VS A19 USAVAC Autotransformer A/T Non Combo
6083VS A19 USAVAC Autotransformer A/T Combo
Pushbutton Stations 6084VS A19 USAVAC Autotransformer A/T Combo
100-RN G15 Mill Type, Form RN,RNG 6090TM B27 Type TM Part Winding Non Combo
100-C G16 Power Press Type C 6083MVS A38 RVAT Med. Voltage Starters
100T D15 Heavy Duty Type 4&13 Enclosed
Pump Control Panels
Remote Switches HP E2 Duplex & Triplex Pump Controllers
101-FS G9 Foot Switches
Control Relays
Master Switches 7304 K12 Type PM, D-C Convertible Pole
101-SD G13 Mill Master, Jr. 7305 K2 Type PM Relay Family
447 K18 Series 447
Limit Switches
102-BST G8 Belt Side Travel Overload Relays
102-HL G2 Hatchway, Type HL,HLD 7324 B31 Type TM, Panel Mounting
102-TL G4 Track Type
Lighting Contactors
AC Contactors Magnetic & Vacuum 7707-LC L2 Type PM
7707TM B5 Type TM, Magnetic General Purpose 7707-LC L5 Type TM
7707VC A11 LV USAVAC Vacuum General Purpose 447 L4 Type 447
7707VC A30 MV USAVAC Vacuum General Purpose
5000 B65 Series 5000 Magnetic General Purpose A-C Definite Purpose Control
7707HP C4 Type HP Magnetic General Purpose 7735-A77 H3 Type DP Contactors

AC Full Voltage Magnetic & Vacuum Starters Fire Pump Controllers


6013TM B7 Type TM Starters 10600 F3 Electric Motor Control
6013VS A15 USAVAC Starters 10710 F4 Diesel Engine Control
6013HP C4 Type HP Starters 10664 F6 Residential Controller
6018TM B13 Type TM Combination Disconnect Switch
6018VS A17 USAVAC Combination Disconnect Switch DC Control
6018HP C6 Type HP Combination Discount Switch 146 J2 Field Loss Relay
6020TM B16 TM Combination Circuit Breaker 5000DP J3 DC Definite Purpose Contactors
6030TM B8 TM Reversing 7000-7001 J4 DC Magnetic Contactors
6030VS A16 VS Reversing 7400 J9 DC Magnetic Contactors
6030HP C5 HP Reversing 7700 J11 DC Contactors for Vehicles
6038TM B18 Type TM Reversing Combination
- With Disconnect Switch
6040TM B19 Type TM Reversing Combination Photoelectric Sensors & Controls
- With Circuit Breaker Disconnect MEK90 M2 User Selectable
6050TM B9 Type TM Two Speed Non Combination
6058TM B20 Type TM Two Speed Combination F/S
6060TM B23 Type TM Two Speed Combination C.B.
6018MVS A37 Type USAVAC Med. Voltage Starters

AC Reversing Contactors
6031TM B6 Type TM General Purpose
6031VC
6031VC
A14
A31
USAVAC General Purpose
MV USAVAC General Purpose
N
6031HP C4 Type HP General Puropse
USAVAC A13 Mechanically Interlocked for Two Speed & 0
Reduced Voltage Applications 2
6

Time Delay Relays


7313 K10 Type PMT A-C Pneumatic
7314 K14 Type PMT DC Pneumatic

N6 Discount ScheduleM1
JC90
Alpha-Numerical Index of Catalog Number Prefixes
Prefix Page Prefix Page Prefix Page

A60 B40,B42 MEK90 M2 VC A11 - A14


A63 B30,C7 MVC A30,A31 VCL A12
A77 B41, B3, H3, A17, MVCL A32 VK B28
A8, A26, A6 MVS A37, A38
A100 G16 SH M23 VS A15 - A18
AK A6, A8 SL D23,D24 VJ A16
A101 G3, G10, G11 - G13 SK D25,D26 VW
A102 G2, G3, G5, G6, SVC A11, A20, A30,A33 VCSK A26
G7 - G13 *
C18 B13, B14, B15 T13 B7 1A D21
CV A17, A19 T18 B13 - B15 1RN G15
C20 B16, B17 T20 B16, B17 100T D2-D20
CR101 C15 T30 B8 4A12 G16
CV A2,A3,A5,A6,A8,A9 T31 B6
DD E2 4U K12
D713U K10 T38 B18
DFP F6 T40 B19 5DP J4 - J5
DP H3, H4, H6 T50 B9 5M B66, J6, J7,J9,J10
DS E2 T58 B20 - B22 5S K8,K9
E18 B13, B14, B15 5U K4, K5, K13
DFP F6 T60 B23, B24
E20 B16, B17 T77 B5,L5 100T D1-D20
EPM K9 T82 B26 146 J2
ETM B40, B41 T90 B27 319L Section N
T95 B26 320L Section N
FH C17 TB Section N 335L Section N
H C20, G2 TS E2 343L Section N
HLD G3 TT E2 344L Section N
HP C5 347L Section N
U A5,A8,A6,A9 447 K18, L4
HPC C4
HPS C6 U82 B26
HPR C5 U77 B5 713U K10, K15
U13 B7 714UP K14
U30 B8 2411-2460 B32 - B34
K18 B28 2514-2541 B34
*SPF F6
K20 B29
KHP C7, C8, H5
KLC L3 5000 B65
KPM K9, K11, L2, L3 5999 B66, J6, J7,J9,J10
KPMT K11 7000&7001 J4
KTB C8, H5 7400 J8
KTM
KTMA
B31, B33, B39 - B42
B30,B31, B33, B44 N
KTR B30, B32, C8 7M J12,J13
KUM B40, B42 9 H5
0 KVC A6,A8,A9,A26
2
6 KS D23,D24,D26
LC L2, L3
KR D24,D26

M1
N7