JCC General Controlog 000
JCC General Controlog 000
11
Index USAVAC
CV Series Page Number
Low Voltage 200V-1500V
AC Contactors CV4
AC Reversing Contactor CV4
A2
A3, A4
A
AC Starters CV4 A5
Rev Starter CV4 A6
Technical Specifications CV4,5&6 Diagrams & A7, A13, A19
Dimensions
AC Contactors CV5 A8
AC Reversing Contactors CV5 A9, A10
AC Starters CV5 A11
AC Rev Starters CV5 A12
AC Contactor CV6 A14
AC Reversing Contactors CV6 A15, A16
AC Starters CV6 A17
AC Rev Starters CV6 A18
CV Series Starter O/L Heaters A35
VC Series
MVC Series
Medium Voltage 2.5 - 7.2KV (Contactors) A39
AC Contactors - 2.5, 5.0, 7.2KV (Mechanically Latched) A40
AC Contactors (Mechanically Interlocked) A41
3
7 AC Special Purpose Contactors - 2.5, 5.0, 7.2KV, 200-3000 amp. A42
5
Technical Specifications A43
Dimensions A44
Medium Voltage Controllers A45
Medium Voltage Modifications A49
A1
AC Vacuum Contactors USAVAC - Low Voltage
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V One Small Size NEMA Size 4 V200
CE IEC 200A
A
600Volt Nema Size 4 135A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower Discount
Open Type
Nema Size 4 KW Rating 3 Phase HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 40/30 50/37 100/75 100/75 CV77U030406-* $1519.00
1500Volt 200AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating 200A Discount
Nema Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
V200 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 1000V 1500V Catalog # Price
HP/KW 50/37 75/59 125/95 150/110 175/130 300/225 500/370 CV77U031615-* $1693.00
Replacement Parts (Discount Schedule JC80)
Options Discount (Schedule JC11) Field Kits
Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77-457211A $520
Lug Kit #6 to 250mcm 3 Per Kit KVC4-2 $82 Coil 110/120V 50/60 HZ A77-460915A-1 $248
Aux. Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460915A-2 $248
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460915A-3 $248
Coil 440/480V 50/60 HZ A77-460915A-4 $248
Coil 125V DC A77-460915A-5 $248
Coil 250V DC A77-460915A-6 $248
Control PAK 110/120 50/60 HZ A77-460916A-1 $258
Control PAK 220/240 50/60 HZ A77-460916A-2 $258
Control PAK 380-415V 50/60 HZ A77-460916A-3 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break
Ordering Information * Coil Table
Voltage Suffix
Use complete catalog number when ordering. 120 AC 76
Engineering Data page A7. 240 AC 26
Replace the (*) with the suffix from the coil table. Renewal Parts page A2. 380 AC 38
460 AC 46
125V DC 125
250V DC 250
3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11
1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price
HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV31U031615-*-43 $3980
3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11
1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price
HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV31U031615-*- $4538
1500Volt 200 AMP Starter 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V200 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 1000V 1500V Catalog # Price
HP/KW 50/37 75/59 125/95 150/110 175/130 300/225 500/370 CV13U031615-* $2654.00
3 Pole Nema Rated ICS-29 IEC947.4.1 (1000V) UL508 1500V CSA 22.2
Mechanically Interlocked Pair Unwired 1500V 200A Contactor
Rating 200A Discount
Maximum Horsepower/KW Rating 3 Phase Open Type
Nema V200 Schedule JC11
1500V 200/208V 220/240V 380/415V 460V 575/660V 1000V 1500V Catalog # Price
HP/KW 50/37 80/59 100/75 150/110 200/150 300/225 500/370 CV30U031615-*- $4988
Coils
A7
USAVAC - Low Voltage AC Vacuum Contactors
UL listed to 1500V Three Ratings CV Series
CSA Certified to 1500V One Small Size NEMA Size 5
CE IEC 400A
A
1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV77U034A15-* $2242.00
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV77U033A15-* $2242.00
600Volt Nema Size 5 270A Mechanically Interlocked Pair Unwired 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV31U030506-*-43 $5984.00
1000Volt 400AMP Mechanically Interlocked Pair Unwired 3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV31U034A06-*-43 $6606.00
1500V 400AMP Mechanically Interlocked Pair Unwired 3 Pole IEC 947-4-1 (1000V) UL508 (1500V)
CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 415/440V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV31U034A15-*-43 $6972.00
Nema V320 100/70 125/95 200/150 300/220 300/220 - 500/370 900/670 CV31U03A15-*-43 $6972.00
600Volt Nema Size 5 270A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200/208V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV13U030506-* $2699
1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1500V 200/208V 220/240V 380/415V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 500/370 700/520 850/650 CV13U034A15-* $3202
Nema V320 100/75 150/112 250/187 300/220 300/220 - 500/370 900/670 CV13U033A15-* $3202
3 Pole Nema ICS-2 UL508 CSA 22.2 Size 5 Reversing Starter 600V 270 AMP
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 5 HP/KW Schedule JC11
600V 200V 230V 460V 575V Catalog # Price
HP/KW 75/56 100/75 200/150 200/150 CV30U030506-* $7269
3 Pole IEC 947-4-4 UL508 CSA 22.2 Reversing Starter 660V 400 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
400A Schedule JC11
1000V 200/208V 220/240V 380/415V 460V 575/600V 660-690V Catalog # Price
HP/KW 100/75 150/112 250/187 300/220 400/300 450/336 CV30U034A06-* $7833
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V) 400A
Description
Cat #
NEMA Size 5 600V
CV77U030506-*
400 Amp 1000V
CV77U034A06-*
400 Amp 1500V
CV77U034A15-*
Motor HP/KW AC3 A
Voltage 270A 400A
Standard NEMA ICS-2 IEC 947-4-1 1000V IEC 947-4-1 1000V
208 75/56 100/75
UL508 CSA22.2 UL508 CSA22.2 NEMA ICS-2.9 1500V
220/240 100/75 150/112
UL508 CSA22.2 1500V 380/415 ---- 250/187
Power Ratings 460 200/150 300/220
Insul. & Operating Volt 600 Volts 1000 Volts 1500 Volts 575/600 200/150 400/300
Rated Oper. AC1 270 Amps 400 Amps 400 Amps 660/690 ---- 450/336
Rated Oper. AC3 200 HP 460/575V 500 HP-370KW-660V 850 HP-650KW-1500V 1000 ---- 700/520
Rated Oper. AC4 120 HP 460/575V 300 HP-260KW-660V 650 HP-570KW-1500V 1500 ---- 850/650
Rated Frequency 50 - 400 Hz
Making Current 4000 Amps Three Phase Transformer Load KVA
Breaking Current 3200 Amps Voltage 270A 400A
Dielectric Strength 6Kv - 1 Min. Interruptor Gap 208 108 144
Interrupting Current 4.6 KA 220/240 114 110
Short Time Current1 Sec. 7000 A 380/400 198 270
Short Time Current 10 Sec. 3200 A 415/440 216 304
Mechanical Life
460/500 238 346
1.2 X 106
575/600 260 414
Elect. Life AC3 Duty 1 X 106
660 342 450
Switching Frequency v600/ Hour 1 Every 6 Sec
1000 520 692
Withstand Current 18KA 50 MS 1500 780 1038
Chop Current Max 0.9 A Three Phase Capacitor Load KVAR
Operating Range -15% + 10% - over Range Voltage Voltage 270A 400A
Inrush Power VA 1100VA 120 ms Duration 208 80 108
Holding Power VA 10-12 VA 220/240 86 124
Opening Time MS 160ms 380/400 148 208
Closing Time MS 20-40ms 415/440 162 228
Pick-Up Voltage 80% Cold 85% Hot or less 460 180 254
575/600 230 312
Drop-Out Voltage 70% or less
1000 390 520
Recommended CPT 400VA Machine Tool Transformer 5% Regulation at 20%pf 1500 584 780
Applications Ratings
Mounting Installation All Planes Contactor Only
Altitude 6600 ft. 2000 Meters
Options
Ambient Storage -65oF (-54oC) +160oF (71oC)
Operating o o o
105 F(41
-40 F (-40 C) +135 o
(57 C)
Vibration / Shock 40Hz - 2G. / 30G.
Lug Kit 2#6-300mcm Cat.# KVC5-2
Weight 26 lbs. 11.8 Kg. Auxilliary Contact Kits
Coils
A13
AC Vacuum Contactors USAVAC - Low Voltage
UL listed to 1500V Three Ratings CVC Series
CSA Certified to 1500V One Small Size NEMA Size 6
CE NEMA V600
A IEC 600A
600Volt Nema Size 6 540A Contactor 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating 3 Phase Discount
Open Type
Nema Size 6 HP/KW Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV77U030606-* $3203
1500V 400AMP Contactor 3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
3 Pole IEC 947-4-1 UL508 CSA 22.2 Mechanically Interlocked Pair Unwired 1000 Volt 600 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A 1000V Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 CV31U036A06-*-43 $13212
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Mechanically Interlocked Pair Unwired 1.5 KV 60AMP
Rating 600A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema V600 Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 1000/750 1200/900 CV31U036A15-*-43 $13432
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200CV31U036V15-*-43 $13432
3 Pole IEC 947-4-1 UL508 CSA 22.2 Mechanically Interlocked Pair Unwired 1000 Volt 600 AMP
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A V600 Schedule JC11
1000V 200/208V 220/240V 400V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 CV31U036A06-*- $16562.00
3 Pole IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Mechanically Interlocked Pair Unwired 1.5 KV 600AMP
Rating 600A Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
Nema 1000V Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 250/187 400/300 600/450 650/485 1000/750 1200/900 CV31U036A15-*- $17477.00
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200 CV31U036V15-*- $17477.00
A16
USA VAC AC Starters
Low Voltage
CE • Three Ratings CV Series
NEMA Size 6 & V 600 • One Small Size NEMA Size 6
IEC 600A IEC 600A
A
600Volt Nema Size 6 540A Starter 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating Discount
3 Phase HP/KW Open Type
Nema Size 6 Schedule JC11
600V 200/208V 2500V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/300 CV13U030606-* $3898
1500 Volt 600 AMP Starter 3 Pole ICS 2-9 IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
600Volt Nema Size 6 540A Starter 3 Pole Nema ICS-2 UL508 CSA 22.2
Rating Maximum Horsepower/KW Rating Discount
3 Phase HP/KW Open Type
Nema Size 6 Schedule JC11
600V 200/208V 250V 460V 575V Catalog # Price
HP/KW 150/112 200/150 400/300 400/200 CV30U030606-* $16602
1000Volt 600A Reversing Starter 3 Pole IEC 947-4-1 UL508 CSA 22.2
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A Schedule JC11
660V 200/208V 220/240V 380/400V 415/440V 460V 575/600V 660-690V Catalog # Price
HP/KW 200/150 200/150 250/187 450/330 400/300 600/450 650/485 CV30U036A06-* $17112
1500 Volt 600 AMP Starter 3 Pole ICS 2-9 IEC 947-4-1 (1000V) UL508 (1500V) CSA 22.2 (1500V)
Rating Discount
Maximum Horsepower/KW Rating 3 Phase HP/KW Open Type
600A Schedule JC11
1500V 200/208V 220/240V 400V 460V 575/600V 660-690V 1000V 1500V Catalog # Price
HP/KW 200/150 200/150 375/280 400/300 600/450 650/485 1000/750 1200/900 CV30U036A15-* $18027
Nema V600 200/150 200/150 375/280 500/350 600/470 - 1100/820 1600/1200 CV30U036V15-* $18027
Replacement Parts (Discount Schedule JC80)
Options (Discount Schedule JC11) Field Kits Description Catalog # Price
Description Catalog # Price Interrupter Phase Assembly A77460880A-2 $851
Wire Size (2) #2-600 mcm KVC6-2 $156 Coil 110/120V 50/60 HZ A77-460930A-1 $284
Aux Contact Kit 2N/O 2N/C 10A 600VAC AK1 $73 Coil 220/240V 50/60 HZ A77-460930A-2 $284
Aux. Contact Kit 2N/O 2N/C 10MA 5VDC AK3 $220 Coil 380/415V 50/60 HZ A77-460930A-3 $284
Coil 440/480V 50/60 HZ A77-460930A-4 $284
Plug Stop Jogging Duty Coil 125V DC A77-460930A-7 $284
Nema Coil 250V DC A77-460930A-8 $284
Size 200V 230V 400V 460V 575V Control PAK 110/120 50/60 HZ A77-460916A-4 $258
6 100HP 120HP 200HP 240HP –
Control PAK 110/120 50/60 HZ A77-460916A-5 $258
V600 150HP 150HP 300HP 375HP 450HP
Control PAK 380-415V 50/60 HZ A77-460916A-6 $258
440-480V 50/60 HZ
Aux. Contact Kit 2N/O 1N/C +1 N/C AK Std. $ 92
Late Break
Ordering Information * Coil Table
Use complete catalog number when ordering. Engineering Data page A19. Voltage Suffix
Replace the (*) with the suffix from the coil table. 120 AC -76
Order Heaters at $18.00 each from page A35 Renewal Parts page A18. 240 AC -26
380 AC -38
460 AC -46
125V DC -125
250V DC -250
Coils
A19
USAVAC - Low Voltage AC Vacuum Contactors
5
UL Listed to 1500V
5 Electrically Held AC or DC Coils
CSA Certified to 1500V
UL/CSA recognized to 3600V
A
3 Pole, 320A, 1500V 3 Pole, 600A, 1500V 3 Pole, 700A, 600V 3 Pole, 1000A, 1500V
One 3 Pole, One 5 Pole, 320A Contactor Two 3 Pole, 320A Contactors
USAVAC Vacuum Contactors mechanically interlocked suitable for use in reversing, Wye-Delta,
reduced voltage auto transformer, and 2 speed single or two winding starters.
Note:
1. To be used for 2 speed single winding applications only. 3. Terminal boots provided on center phase.
2. Modification 43 in the catalog number suffix means power 4. Terminal boots provided on all phases.
wiring between contactors not included.
250 HP 460V Jog Duty Reverser with M.O.V. Suppressors 300 HP 575V Reverser
160 50 60 100 125 150 300 420 4 VC31U03415 - * $ 7302. VJ31U03406 - * $ 7979.
320 100 125 200 250 300 600 850 5 VC31U03515 - * 8144. VJ31U03506 - * 8748.
600 200 200 375 500 575 1200 1600 6 VC31U03615 - * 16452. VJ31U03606 - * 17129.
Note:
1. To be used when application involves plugging & inching (e.g. crane control). M.O.V. suppressor included on
power circuit. For other voltages consult factory.
2. Terminal boots provided on center phase.
Note:
1. Three overload heaters are required see page A26 3. Terminal boots provided on center phase.
2. Two 320 ampere contactors connected in parallel for 600A. 4. Terminal boots provided on all phases.
300 HP 460V Starter in Type 12 Enclosure 400 HP 600V Starter in Type 3 Enclosure
Fusible
135 40 50 75 100 125 4 CV18TA340692 - * 5474.
200 50 60 100 125 150 4 CV18TA3E0692 - * 6497.
270 100 100 200 200 200 5 CV18TA35694 - * 6863.
400 160 160 270 300 400 -- CV18TA34A697 - * 9113.
600 180 250 300 500 500 6 CV18TA360698 - * 15354.
MCP
135 40 50 75 100 125 4 CV20TA340678 - * 5765.
200 50 80 135 150 200 -- CV20TA37678 - * 6863.
270 100 100 200 200 200 5 CV20TA350679 - * 7229.
400 160 160 270 300 400 -- CV20TA34A681 - * 9992.
600 180 250 300 500 500 6 CV20TA360681 - * 16799.
For NEMA 3R use NEMA 12 price and change 5th character of catalog number to
"R".
For KW Rating Multiply HP Ratings by .746 (example: 100HP x .746 = 75KW)
Note:
1. Three overload heaters are required.
250 HP 460V Starter in Type 12 Enclosure 300 HP 600V Starter in Type 3 Enclosure
Fusible
135 40 50 75 100 125 4 VS18TA340692 - * 5472.
2
160 50 60 100 125 150 4 VS18TA3E0692 - * 6497.
2
320 100 100 200 250 300 5 VS18TA350694 - * 6863.
600 180 250 300 500 500 6 VS18TA360697 - * 15354.
700 225 300 500 550 700 -- VS18TA370698 - * 16141.
MCP
135 40 50 75 100 125 4 VS20TA340678 - * 6057.
160 50 60 100 125 150 4 VS20TA3E0678 - * 6551.
320 100 100 200 250 300 5 VS20TA350679 - * 7119.
600 180 250 300 500 500 6 VS20TA360680 - * 16214.
700 225 300 500 550 700 -- VS20TA370681 - * 19618.
For NEMA 3R use NEMA 12 price and change 5th character of catalog number to "R".
Note:
1. Three overload heaters are required.
2. Terminal boots provided on center phase.
2
4
5
Auto transformers are 3-coil type, with voltage taps at 50%. 65%
and 80% rated in accordance with NEMA Standards ICS-214.21
for medium-duty starting service.
Note:
2
4
1. Includes starter complete with 3 N.O. & 2 N.C. interlocks and three phase overload relays less heaters.
5 2. Terminal boots provided on center phase.
D
3. For NEMA 3R change the T in the catalog number to an R.
The following controls are for high current applications such as electric arc and induction furnace.
Note:
1. Insulation boots provided on 1 pole.
2. Terminal boots provided on all phases.
A30
Low & Medium Voltage - USAVAC Dimensions
A31
Dimensions USAVAC - Low Voltage
700 Amp
A 600V
3 Phase
A32
Low Voltage - USAVAC Dimensions
A33
Dimensions USAVAC - Low Voltage
A34
USAVAC - Low & Medium Voltage Overload Heaters
Heater Selection Ambient Correction
Select heaters based on motor nameplate full-load current. Tables are Not necessary when overload relay is ambient compensated as
for continuous rated motors. Full-load current for a given horsepower identified by green reset rod. For control at an ambient constantly less
motor will vary from one manufacturer to another and will depend on RPM than the motor ambient, correct by decreasing the nameplate motor
of motor. full-load current by 8% per 100C difference in ambient.
For control at an ambient constantly greater than the motor ambient,
A
Type of Protection correct by increasing the nameplate motor full-load current by 8% per
Heaters selected directly from the tables provide a maximum of 125% 100C difference in ambient.
protection at 400C ambient, is suitable for motors with a 1.15 service
factor with a 400C rise or less and with motor and controller at the same Branch Circuit Protection
temperature. For motors with 1.0 service factor or with a temperature Branch circuit protection should be provided per USA National Electric
rise greater than 400C without service factor rating, use one size smaller Code or the Canadian Electrical Code. Current rating of the protective
heaters than in table. The ultimate trip of the heater is approximately 125% device must not exceed the maximum value listed in the table.
of the minimum current shown in the tables in a 400C ambient.
The overload relay provides protection in accordance with UL Class 20. Automatic Reset
For further data refer to Controlog section B. Automatic reset operation should not be used with two-wire control.
Note:
1. When ordering for 600A Rating, Qty. (2) of a 320A Phase Assembly are required Per Pole.
When ordering for a 1000A Rating, Qty. (3) of a 320A Phase Assembly are required Per Pole.
Example:600A = 2-A77-354115A-2, Price $1214 X 2 = $2428. Total For 1 Pole.
1000A = 3-A77-354115A-2, Price $1214 X 3 = $3642. Total For 1 Pole.
A36
Low
USAVAC - Vacuum Control Voltage Modifications
3
7
Ordering & Pricing Example: 5
Modifications
A Description Price
Change Cat. No.
Character Indicated To: Typical Catalog Number
Overload Relay
$
777 Electronic Motor Management Relay 970 1775. 2728
RM 2000 motor Monitor for use with 777 DEDUCT 695. 29
27A
Power Circuit
Standard Capacity - Primary Volts/Hertz:
220-240/60 or 220/50 -T26
440-480/60 or 440/50 747. -T46
550-600/60 or 550/50 -T56
200-208/60 -T86
380/50 1021. -T35
220/25 -T22
440/25 1120. -T42
100 Watts Extra - Primary Volts/Hertz:
220-240/60 or 220/50 -C26
440-480/60 or 440/50 966. -C46
550-600/60 or 550/50 -C56
200-208/60 -C86
380/50 -C35
220/25 -C22
VS 18 A A 3 1 6 0 3 - 46 -( )
440/25 1449. -C42
Fused Primary (Includes 2 Fuses) 242. 30
Control Circuit Separate N/C 31
Fused Control Circuit, 2 fuses included 242. 32
33 Phase
Phase Voltage
Voltage Monitor Relay (Phase
Monitor Relay, loss, Phase
Phase loss, Phase reversal
reversal) 2141. 33A
Ammeter & 1-Current Transformer
Ammeter, Switch,
Digital Power Meter& 3-Current Transformers 1700.
Voltmeter 3 Phase
* Ammeter 3 Phase * Digital Power Meter: 1700.
Voltmeter
* Voltmeter& 3Switch
Phase3 Phase All functions included in 1700.
Elapsed
* Power Time
(KW)Meter
Wattmeter Mod. 35A 3
Wattmeter
* Energy (KWH) KWH Meter 48.
Watthour
* PF MeterMeter 3331. 35A
Operations
* FrequencyCounter
Meter 8 Digit 348.
Space Heater
* Reactive with(KVAR)
Power N.C. Auxiliary 604.
Contactors without Power Wire N/C
Contactors MI 320/160A 3 Phase ---- See page A22
Contactors MI 600/320A 3 Phase ---- See page A22
4
7
Ordering & Pricing Example:
5
VS18TA350694-76 with the following modifications: VS18TA350694-76 6863.
1 - 3 Phase Voltage Monitor Relay (Phase loss, Phase reversal) . . . . . . . . . . . . . . . . . . . 33A +2141.
Complete Cat# VS18TA350694-76-33A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 9004. Total
Note:
1. UL recognized 5KV 500A 7.2KV 400A 3
CSA Certified 5KV 400A 7
5
A With Separate
Mechanically Latched
Close and Trip Coils
Note:
Mechanically Interlocked Contactors on Page A41 should be used if short circuit
current can flow when switching between two or more contactors.
The following controls are for high current applications such as electric arc and induction furnaces.
3
9
5
Power Ratings
Operational Rated Current 200A 400A 600A 800/1200A
Operational Rated Frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
E1 Interrupt Rating 2.5KV 20 MVA Equivilent to 4.62 KA --------
MVA & KA Values 5.0KV 40 MVA Equivilent to 4.62 KA --------
Contactor Only 7.2KV 60 MVA Equivilent to 4.81 KA --------
E2 Fuse Co-ordination Rating 400 MVA 45.7 KA RMS --------
MVA & KA 5.0KV 38R max. fuse size
Withstand KA 5.0KV 57.8 KA - Peak, 38R - Fuse --------
Short Time Current 1 Sec. KA 6 7 9 12
5 Sec. KA 4 5 6 9
Power Application Ratings 15 Sec. KA 2 2.6 3 6
Switching Frequency 300/Hr
Voltage KV 2.5 3.3 4.16 6.6
Elec. Life at Rated Current .6 x 106 .40 x 106 .250 x 106 .250 x 106
Motor Type Current Motor HP Mechanical Life .75 x 106
.8 P.F. Ind. Dielectric Strength 20KV 1 min.
or Syn Motor 200A 900 1250 1500 2500 Impulse withstand B.I.L. 1.2 x 50 us
1.0 P.F. Syn 60KV
Motor 200A 1000 1500 1750 2750 Chopping Current Max. .9A
.8 P.F. Ind.
or Syn Motor 400A 1750
Control Ratings AC&DC
2250 3000 5000
1.0 P.F. Syn Rated Control Voltage 120/240V 50/60Hz AC 125/250V DC
Motor 400A 2000 2500 3500 5250 Allowable Fluctuation +10-15% +10-20%
.8 P.F. Ind. Closing Power VA/Duration 650VA/45MS 1300VA/45MS
or Syn Motor 600A 2250 3250 4500 6750 Holding Power 7VA AC .47A DC 14VA AC .924A DC
1.0 P.F. Syn Opening Time Ave. 90 MS at 60Hz
Motor 600A 2250 3500 4750 7000 Closing Time Ave. 40 MS at 60 Hz
.8 P.F. Ind. Pick up Voltage Min. 102V or less
or Syn Motor 800A 2750 4000 5500 8000 Drop Out Voltage Ave. 70% or less
Transformer Load KVA Recommended Control Trans. (AC Only) 300VA 600VA
Three 200A 750 1000 1500 2000
Application Conditions
Phase 400A 1500 2000 3000 4000
Transformer 600A 2500 3000 4250 6000 Standard Current Continuous AC/DC 10A/5A
800A 2750 3750 5250 7500 Auxiliary Voltage 600V Max. - 48V Min. NEMA A600 (AC) P600 (DC)
1200A 4100 5000 7000 10000 Contact AC Make/Break 7200VA/720VA
Capacitor Load KVAR Ratings DC Make/Break 125/250V 138VA 300/600V 138VA
Three 200A 550 750 1050 1500 Additional Current Continuous AC/DC 10A/2.5A
Phase 400A 1125 1500 2250 3000 Auxiliary Contact Voltage 600V Max. - 48 Min. NEMA A600 (AC) Q300 (DC)
Capacitor 600A 1650 2250 3375 4500 Relay Ratings AC Make/Break 7200VA/720VA
800A 2200 2900 4500 5000 DC Make/Break 125/250V/69VA
1200A 2750 3750 5625 7500 Weight 48 lbs. 96 lbs.
A43
USAVAC - Medium Voltage Dimensions
13.5" 12.63"
12"
B 26"
A 27.5"
2 600 AMP
A = 32"
B = 30.5"
A44
Dimensions Medium Voltage - USAVAC
A45
USAVAC Medium Voltage Controllers
Free Standing, Single High Compact Vacuum Starter in NEMA 12
FULL VOLTAGE Enclosures. Designed to comply with NEMA1CS2-324 Class E 2
NON REVERSING - REVERSING controller.
Features Offered:
A UL 347 LISTED
• Fault Make, Load break visible blade disconnect
switch with automatic grounding arm.
CSA 2-22 APPROVED • Grounded metal isolation between LV and
Medium Voltage Compartments.
• Maintenance free Joslyn Clark Vacuum Contactors.
• Suitably rated current limiting power fuses with
striker pins and 3 phase trip bar.
• C.P.T. provided with 2 primary and 1 secondary
fuses, 120V secondary.
Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
2300V VACUUM STARTERS With Fused Load Break Disconnect
160* 125 MVS18TA31A25A-T236 $17751
160* 150 MVS18TA31A25B-T236 17751
160* 250 MVS187A31A25C-T236 17751
160* 350 MVS18TA31A25D-T236 17916
160* 500 MVS18TA31A25E-T236 17916
160* 600 MVS18TA31A25F-T236 17952
200 750 MVS18TA32A25A-T236 18026
200 1000 MVS18TA32A25B-T236 18154
320* 1250 MVS18TA33A25A-T236 18483
400 1500 MVS18TA34A25A-T236 21045
600 2250 MVS18TA36A25A-T236 24449
Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
4160V VACUUM STARTERS With Fused Load Break Disconnect
200 200 MVS18TA32A50A-T416 $18117
200 350 MVS18TA32A50B-T416 18263
200 400 MVS18TA32A50C-T416 18263
200 500 MVS18TA32A50D-T416 18392
200 600 MVS18TA32A50E-T416 18392
200 750 MVS18TA32A50F-T416 18520
200 1000 MVS18TA32A50G-T416 18520
200 1250 MVS18TA32A50H-T416 18666
200 1500 MVS18TA32A50J-T416 18666
400 3000 MVS18TA34A50A-T416 21594
600 4500 MVS18TA36A50A-T416 25547
Maximum NEMA 12
Ampere Rating HP Ratings Catalog No. Price
7200 V
200 350 MVS18TA32A72A-T666 $20313
200 500 MVS18TA32A72B-T666 20313
200 750 MVS18TA32A72C-T666 20679
200 1000 MVS18TA32A72D-T666 20954
200 1500 MVS18TA32A72E-T666 21356
200 2000 MVS18TA32A72F-T666 22582
200 2500 MVS18TA32A72G-T666 23534
400 3500 MVS18TA34A72A-T666 24522
400 5000 MVS18TA34A72B-T666 26901
600 6750 MVS18TA36A72A-T666 32300
NOTE. For Reversing Applications add $9608. to list prices and change 4th and 5th digit of cat # from 18 to 31.
For Inching or Plugging Duty Refer to Factory.
For Latched Contactors change "MVS" to "MVSL" - - Add $1281. To List Price & specify Trip Coil Voltage.
* These Starters have 45KV BIL Rating if 60KV Required use 200A or 400A Rated Starters.
For NEMA 3R Rating Change 5th Digit from “T” to”R” & add $458 to list
Ordering Information
Engineering Data page A43 Renewal Parts page A36
Modification Data page A49 & 50
KVA KVAR
Ampere Rating Ratings Rating Catalog No. Price
2300V VACUUM STARTERS With Fused Load Break Disconnect
KVA KVAR
Ampere Rating Ratings Rating Catalog No. Price
4160V VACUUM STARTERS With Fused Load Break Disconnect
Ordering Information
Engineering Data page A43 Renewal Parts page A36
Modification Data page A49 & 50
Max HP Cat # NEMA 12 List Price Max HP Cat # NEMA 12 List Price
*100 MVS83TA31A25A-T236 $32226. *1250 MVS83TA33A25F -T236 $40013.
*200 MVS83TA31A25B-T236 33050. 1500 MVS83TA34A25G-T236 41248.
*400 MVS83TA31A25C-T236 34953. 1750 MVS83TA36A25H-T236 43554.
*900 MVS83TA33A25D-T236 36637. 2000 MVS83TA36A25J -T236 45338.
*1000 MVS83TA33A25E-T236 38522. 2250 MVS83TA36A25K-T236 46976.
3
NOTE.
9
For NEMA 3R Replace 6th cat.# digit 'T' with 'R' and add $458. to list price. 5
For Reversing Applications add $13725. to list prices and change 4th and 5th digit of cat# from 83 to 86
For Inching or Plugging Duty Refer to Factory.
For Latched Contactor Change "MVS" to "MVSL" - - - Add $1464. to list price & specify trip voil voltage, refer controlog page A40.
* These Starters have 45KV BIL Rating for, 60KV Rating - - - Add $1556. to list price change cat# after TA31 to TA32 or TA33 to TA34.
Ordering Information
Engineering Data page A43 Renewal Parts page A36. • Modification Page A49 & 50
A Description
Change Cat. No.
Price Character Indicated To: Typical Catalog Number
3 Phase Voltage Monitor Relay, Phase loss, Phase reversal 2141. 33A
4
3
0
B1
TM - NEMA Control General Information
Reliability - The basic contactor design, using polysulphone and teflon Versatility - Uniform mounting dimensions Add-on auxiliary
guides, melamine and rosite moldings along with stainless steel springs, contacts Plug-in coils Accessories, such as power pole,
provides exceptional electrical and mechanical life. The operating state mechanical interlock pro-vides maximum versatility and flexibility of
is clearly visible from the front, indicated by the position of the contact inventory panel layout and installation. Self-rising saddle-clamps
carrier.The contactor is easily operated from the front for circuit check- are included on all control terminals for quick wiring.
ing.
B2
General Information NEMA Control - TM
3
8
0
Compact Size - Integral overload relay design, with straight Uniform Mounting Dimensions - Only 2 mounting plate sizes for 00
through power cable design, provides compact overall size. through 4 starters. One mounting plate for sizes 00-2, the second for
Straight through wiring reduces overall panel area for a sizes 3 & 4. This provides great flexibility for intermixing
NEMA wired device. Uniform mounting dimensions, along with starter sizes in rows and reduces panel layout time.
mechanical interlock design, makes reversing devices and other Pilot Device Kits - Operator devices may be added in the field. Push
mechanically interlock devices the same height and depth as button and pilot light kits for non-combination enclosures are suitable for
nonreversing. This allows intermixing in rows and saves panel use in NEMA Type 1, 4 & 12. This simplifies selection and increases
space. flexibility.
B3
TM - NEMA Control General Information
Non-Reversing
Bulletin 6013 NEMA Starters.
Bulletin 7707 NEMA Contactors.
NEMA Size 00-6.
B NEMA Type 1, 4 & 12 Enclosures.
NEMA Size 00-2.
NEMA Type 3R Enclosure.
Bulletin 6013 Starters are available single phase through
size 2P, 3 phase through size 6.
Bulletin 7707 Contactors are available 2 & 3 pole through
size 6 and 4 pole thru size 4.
Reversing
Bulletin 6030 NEMA Starters.
Bulletin 6031 NEMA Contactors.
NEMA Size 00-6.
NEMA Type 1, 4, 12 Enclosures
Bulletin 6030 reversing starters and Bulletin 6031
reversing contactors include mechanical and
electrical interlocks.
Multi-Speed
Bulletin 6050 NEMA Starters.
NEMA Size 0-5.
NEMA Type 1, 4 & 12 Enclosures.
Bulletin 6050 multi-speed starters are designed for two-speed,
single winding (consequent pole) and two-speed, two winding
(separate winding) motor applications.
Mechanical and electrical interlocks are included.
Starters for three and four speed motor applications can also 3
be supplied. 8
0
B4
AC Contactors NEMA Control - TM
3
7
Note: 1. Price includes contactor complete with one N.O. control-circuit contact.
5 2. This unit replaces T77 (size 5) and is not interchangeable.
Note:
1. Price includes starter complete with one N.O. contact on each contactor and 3 phase overload relay less heaters.
3
7
2. This unit replaces T77 (size 5) and is not interchangeable.
5 3. For Ambient Compensated overload see B37.
10 15 25
2
(7 1/2) (10) (20)
T50AA2C2 - * 3624. T50WA2C2 - * 5016. T50TA2C2 - * 4152. T50UO2C2 - * 3408.
25 30 50
3
(20) (20) (40)
T50AA3C2 - * 5472. T50WA3C2 - * 7536. T50TA3C2 - * 6672. T50UO3C2 - * 5136.
40 50 100
4
(30) (40) (75)
T50AA4C2 - * 14616. T50WA4C2 - * 18840. T50TA4C2 - * 16992. T50UO4C2 - * 13296.
75 100 200
5 Consult Factory
(60) (75) (150)
2 Speed, Double Winding (separate winding)
3 3 5
0
(2) (2) (3)
T50AA0S2 - * 1320. T50WA0S2 - * 2472. T50TA0S2 - * 1692. T50UO0S2 - * 1272.
1
7 /2 7 1/2 10
1 1 T50AA1S2 - * 1488. T50WA1S2 - * 2616. T50TA1S2 - * 1860. T50UO1S2 - * 1416.
(50) (5) (7 /2)
10 15 25
2
(7 1/2 ) (10)
T50AA2S2 - * 2664. T50WA2S2 - * 4080. T50TA2S2 - * 3192. T50UO2S2 - * 2472.
(20)
25 30 50
3
(20) (20) (40)
T50AA3S2 - * 4176. T50WA3S2 - * 6240. T50TA3S2 - * 5376. T50UO3S2 - * 3840.
40 50 100
4
(30) (40)
T50AA4S2 - * 10248. T50WA4S2 - * 14472. T50TA4S2 - * 12624. T50UO4S2 - * 9624.
(75)
75 100 200
5 Consult Factory
3 (60) (75) (150)
8
0
Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All
starters are mechanically and electrically interlocked. Six (6) heaters are required, 3 for each speed rated for HP ratings.
Non-Reversing
Bulletin 6018 with disconnect switch, fusible
and non-fusible.
Bulletin 6020 with Circuit Breaker 250V thermal
magnetic trip breaker or 600V adjustable
magnetic trip MCP. breaker.
B NEMA Size 0-6.
NEMA 1, 4 & 12 enclosures.
Choose standard, compact or extra-wide
enclosure style of enclosure for Sizes 0, 1 & 2.
All three styles are available in NEMA 1, 4 & 12
enclosure.
Sizes 3 & 4 are available in standard and extra-
wide enclosure styles.
Size 6 is supplied in the standard enclosure style
and includes Vacuum contactor.
Each starter includes disconnect device and TM
non-reversing starter.
Extensive field modification kits and factory
installed modifications are available.
Reversing
Bulletin 6038 with disconnect switch, fusible
and non-fusible.
Bulletin 6040 with circuit breaker.
250V thermal magnetic trip breaker or 600V
adjustable brip MCP. breaker.
NEMA Size 0-5.
NEMA 1, 4 & 12 Enclosures.
Each includes disconnect device and TM
reversing starter.
Extensive field modification kits and factory
installed modifications are available.
Multi-Speed
Bulletin 6058 with disconnect switch, fusible
and non-fusible.
Bulletin 6060 with Circuit Breaker.
600V MCP. breaker.
NEMA Size 0-6.
NEMA 1, 4 & 12 enclosures.
Each includes disconnect device and TM multi-
speed starter.
They are cataloged for two-speed, single winding
(consequent pole) and two speed, two
winding (seperate winding) motor application. 3
B10
General Information NEMA Control - TM
Combination Starters & Contactors
Disconnect Device Disconnect Operator
Disconnect switches are heavy duty, Flange mounted operating handle pro-
visible blade type with positive drive vides positive control of the disconnect.
action and meet industrial with stand Interlocking prevents opening the door
requirements.
with the disconnect "ON" or turning the
Above 100 amp., a non-automatic circuit
breaker with fuse clips is provided. disconnect "ON" with the door open.
Mounting plates include drilling for field Interlock defeaters are provided for
conversion of fuse size and spacing. maintance. B
Circuit breaker type starters use motor The position of disconnect is clearly
circuit protectors with a single, seven-point visible to determine if controller is "ON" or
trip adjustment and manual trip feature. An "OFF".
optional current limiter attachment provides A red handle flag is visible in the "ON"
200,000 amp. rms symmetrical interrupting state.
capacity.
Padlocking
Door Swing Operating handles can be padlocked in
The concealed hinge design allows 150o "OFF", with up to 3/8" shackle locks.
door swing for interior accessibility. Doors can be locked closed with one 3/8"
shackle lock, thus providing security to
Uniform Enclosure equipment and safety to personnel.
One enclosure covers Size 0, 1 & 2, for
each enclosure style. White Mounting Plate
Sizes 3 & 4 are covered by a single Baked ANSI safety white enamel is used
enclosure. for the mounting plate. This provides
NEMA 1, 4 & 12 enclosure designs are
increased visibility for safety.
each the same basic size, for each
enclosure style. All this for flexibility, ease
of layout and ease of installation. Add-On Accessories
Most TM starter add-on accessories can
be installed in combination starters.
Mounting plates are pre-drilled for field
Grounding installation of additional control devices.
A UL recommended type, green head
screw is provided for grounding the
enclosure. Quality Enclosure Construction
A green ground wire is installed in the Painted surfaces are baked enamel for
non-fused leg of control transformers. long life.
All unpainted hardware is plated for
corrosion resistance.
Door Gasketing
Hinge pins are stainless steel.
Standard on NEMA 4 & 12 and optional on
NEMA 1. Gasketing is neoprene, extruded, NEMA 4 enclosures are #304 stainless
closed cell type for increased life, sealing steel for appearance and corrosion
qualities and safety for the installer. resistance.
B11
TM - NEMA Control General Information
Versatility
Choose an enclosure style to meet the
application.
Check the enclosure sizes to simplify your
starter layouts.
Check the interchangeability of mounting
plates.
Choose add-on accessories for the basic TM
starter.
Select from a wide range of factory modifications
and field modification kits.
All of this to improve application flexibility with
minimum inventory requirements. This is the
versatility of TM combination starters.
Pilot Devices
A complete selection of field modification kits or
factory installed operator devices are
available.
Most are arranged for mounting on the enclo-
sure flange, eliminating the need for a flexible
wire harness to the door.
Control Transformer
Available factory installed or as a field modifica-
3
tion kit.
7
All starters can accommodate a 100VA extra
5
capacity transformer in every enclosure style
and type.
Secondary fusing standard.
B12
AC Combination Starters NEMA Control - TM
Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters. 5
2. Class R fuse clips available on request. 0
2
Note:
2 1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.
4 2. Class R fuse clips available on request.
1
0 18
* $ 1176.
T20WA30201 - * $ 2328. * $1464.
3 3 20 T20AA30202 - * T20WA30202 - * T20TA30202 - *
5 5 40 T20AA31203 - * T20WA31203 - * T20TA31203 - *
1 27 1236. 2388. 1524.
7 1/2 7 1/2 50 TEB T20AA31204 - * T20WA31204 - * T20TA31204 - *
10 10 50 T20AA32204 - * 1896.
T20WA32204 - * 3672.
T20TA32204 - * 2304.
2 45
15 15 70 T20AA32205 - * T20WA32205 - * T20TA32205 - *
25 25 100 T20AA33206 - * 3264.
T20WA33206 - * 6360.
T20TA33206 - * 3792.
3 90
30 30 150 T20AA33208 - * T20WA33208 - * T20TA33208 - *
TED
40 40 150 T20AA34208 - * 7164
T20WA34208 - * 11118.
T20TA34208 - * 8628.
4 135
----- 50 150 TEC T20AA34677 - * T20WA34677 - * T20TA34677 - *
50 ----- 200
5 60 60 270 225 TJK4 Consult Factory
75 100 300
Compact - Horizontal
2 2
18
15 C20AA30201 - *
1176.
C20WA30201 - * C20TA30201 - * 1464.
0 2328.
3 3 20 C20AA30202 - * C20WA30202 - * C20TA30202 - *
5 5
27
40 C20AA31203 - *
1236.
C20WA31203 - * C20TA31203 - * 1524.
1 TEB 2388.
7 1/2 7 1/2 50 C20AA31204 - * C20WA31204 - * C20TA31204 - *
2
10 10
45
50 C20AA32204 - *
1896.
C20WA32204 - * C20TA32204 - * 2304.
3672.
15 15 70 C20AA32205 - C20WA32205 - * C20TA32205 - *
Extra Wide
2 2 15 E20AA30201 - * E20WA30201 - * E20TA30201 - *
0 18 1320. 2820. 1680.
3 3 20 E20AA30202 - * E20WA30202 - * E20TA30202 - *
5 5 40 E20AA31203 - * E20WA31203 - * E20TA31203 - *
1 27 TEB 1380. 2880. 1740.
7 1/2 7 1/2 50 E20AA31204 - * E20WA31204 - * E20TA31204 - *
10 10
45
50 E20AA32204 - * 2040.
E20WA32204 - * 4164.
E20TA32204 - *
2 2520.
15 15 70 E20AA32205 - * E20WA32205 - * E20TA32205 - *
25 25
90
100 E20AA33206 - * 3504.
E20WA33206 - * 7320.
E20TA33206 - *
3 4182.
30 30 150 E20AA33208 - * E20WA33208 - * E20TA33208 - *
TED
4
40 40
135
150 E20AA34208 - * 7464.
E20WA34208 - * 12444.
E20TA34208 - *
9228.
----- 50 150 TEC E20AA34677 - * E20WA34677 - * E20TA34677 - *
Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.
Note:
1. Includes starter complete with N.O. contact and 3 phase overload relays less heaters.
3
8
0 Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace the Renewal Parts - see Page B42 24/60 or 24/50 -96
(*) with the suffix from the coil table. Order Engineering Data - see Page B50 110-120/60 or 110/50 -76
heaters at $18 each. Modifications - see Page B36 220-240/60 or 220/50 -26
Heater Tables - see Page B33 440-480/60 or 440/50 -46
Dimensions - see Page B47 550-600/60 or 550/50 -56
200-208/60 -86
Non-Fusible
Maximum Motor Starter NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Disconnect GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460/ Ampere Switch Enclosure Enclosure
Size 200V 230V 575V Rating Rating Catalog No. Price 1 Catalog No. Price 1 Catalog No. Price 1
Notes:
1. Includes starter complete with N.O. contact, disconnect switch less fuses, and 3 phase overload relay less heaters.
2. Class R fuse clips are available on request.
4
2
0
AC Combination Reversing Starters with Motor Circuit Protector, 600V - Bulletin 6040
Maximum Motor Starter Circuit Magnetic NEMA Type 1 NEMA Type 4 NEMA Type 12
Horsepower Rating Cont. Breaker Trip Motor GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA 460/ Amps Ampere Circuit Enclosure Enclosure
1 1 1
Size 200V 230V 575V Rating Rating Protector Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 18 3 T40AA30671 - * T40WA30671 - * T40TA30671 - *
0 1 1/2 1 1/2 3 18 7 T40AA30672 - * $2148. T40WA30672 - * $ 3612. T40TA30672 - * $2556.
3 3 5 18 15 T40AA30673 - * T40WA30673 - * T40TA30673 - *
1
/2 1
/2 1 1/2 27 3 T40AA31671 - * T40WA31671 - * T40TA31671 - *
1 1/2 1 1/2 3 27 7 T40AA31672 - * T40WA31672 - * T40TA31672 - *
1 * 2292. 3756. * 2700.
3 3 5 27 15 T40AA31673 - T40WA31673 - * T40TA31673 -
7 1/2 7 1/2 10 27 30 TEC T40AA31674 - * T40WA31674 - * T40TA31674 - *
7 1/2 7 1/2 10 45 30 T40AA32674 - * T40WA32674 - * T40TA32674 - *
2 * 3660. 5892. 4188.
10 15 25 45 50 T40AA62675 - T40WA62675 - * T40TA62675 - *
3 25 30 50 90 100 T40AA33676 - * 5472. T40WA33676 - * 9384. T40TA33676 - * 6168.
4 40 50 100 135 150 T40AA34677 - * 12396. T40WA34677 - * 17340. T40TA34677 - * 14304.
5 75 100 200 270 400 TJC4 Consult Factory
Note:
3
8
1. Includes starter with N.O. contact, circuit breaker and 3 phase overload relays less heaters.
0
Non-Fusible AC 2 Speed Starter with Disconnect Switch, 200, 230, 460 and 575V
2 Speed, Single Winding (consequent pole), Bulletin 6058
Maximum Motor
B Horsepower Rating
Constant or Variable Starter Disconnect NEMA Type 1 NEMA Type 4 NEMA Type 12
Torque ( Constant Continue Switch GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Horsepower) 460- Ampere Ampere Enclosure Enclosure
1 1 1
Size 200V 230V 575V Rating Rating Catalog No. Price Catalog No. Price Catalog No. Price
3 3 5
0 18 30 T58AA0C2610 - * $2976. - use size 1 - * - use size 1 - *
(2) (2) (3)
7 1/2 7 1/2 10
1 27 30 T58AA1C2610 - * 3120. T58WA1C2610 - * $ 4968. T58TA1C2610 - * $ 3516.
(5) (5) (7 1/2 )
10 15 25
2 45 60 T58AA2C2610 - * 5064. T58WA2C2610 - * 7368. T58TA2C2610 - * 5688.
(7 1/2) (10) (20)
25 30 50
3 90 100 T58AA3C2610 - * 7296. T58WA3C2610 - * 11232. T58TA3C2610 - * 8664.
(20) (25) (40)
40 50 100
4 135 150 T58AA4C2610 - * 17136. T58WA4C2610 - * 23328. T58TA4C2610 - * 21048.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)
3 3 5
0 18 30 T58AA0S2610 - * 2448. - use size 1 - * - use size 1 - *
(2) (2) (3)
7 1/2 7 1/2 10
1 27 30 T58AA1S2610 - * 2616. T58WA1S2610 - * 4464. T58TA1S2610 - * 3012.
(5) (5) (7 1/2 )
10 15 25
2 45 60 T58AA2S2610 - * 4104. T58WA2S2610 - * 6432. T58TA2S2610 - * 4728.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T58AA3S2610 - * 6000. T58WA3S2610 - * 9936. T58TA3S2610 - * 7368.
(20) (25) (40)
40 50 100
4 135 150 T58AA4S2610 - * 12768. T58WA4S2610 - * 18960. T58TA4S2610 - * 16680.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)
3
8
0
Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All starters
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
3 3
0 18 30 T58AA0S2203 - * 2640. - use size 1 - * - use size 1 - *
(2) (2)
7 1/2 7 1/2
1 27 30 T58AA1S2203 - * 2808. T58WA1S2203 - * 4656. T58TA1S2203 - * 3204.
(5) (5)
10 15
2 45 60 T58AA2S2206 - * 4200. T58WA2S2206 - * 6528. T58TA2S2206 - * 4824.
(7 1/2) (10)
25 30
3 90 100 T58AA3S2201 - * 6624. T58WA3S2201 - * 10560. T58TA3S2201 - * 7992.
(20) (25)
40 50
4 135 150 T58AA4S2202 - * 14592. T58WA4S2202 - * 20784. T58TA4S2202 - * 18408.
(30) (40)
75 100
5 270 400 Consult Factory
(60) (75)
Note:
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All
starters are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
5 5
0 18 30 T58AA0S2603 - * 2640. - use size 1 - * - use size 1 - *
(3) (3)
7 1/2 7 1/2
1 27 30 T58AA1S2603 - * 2808. T58WA1S2603 - * 4660. T58TA1S2603 - * 3204.
(5) (5)
10 15
2 45 30 T58AA2S2606 - * 4200. T58WA2S2603- * 6530. T58TA2S2603 - * 4820.
(7 1/2 ) (10)
25 25
2 45 60 T58AA3S2601 - * 4452. T58WA2S2606 - * 6530. T58TA2S2606 - * 4820.
(20) (20)
50 50
3 90 100 T58AA3S2602 - * 6624. T58WA3S2601 - * 10080. T58TA3S2601 - * 7510.
(40) (40)
100 100
4 135 200 T58AA4S2604 - * 14592. T58WA4S2602 - * 19490. T58TA4S2602 - * 17140.
(75) (75)
Note: 5
1. Includes starter complete with one N.O. contact on each contactor and two 3 phase overload relays less heaters. All starters 0
2
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace Engineering Data - see Page B49 24/60 or 24/50 -96
the (*) with the suffix from coil table. Modification - see Page B35 110-120/60 or 110/50 -76
Order heaters at $18 each. Renewal Parts - see Page B41 220-240/60 or 220/50 -26
Heater Tables - see Page B32 440-480/60 or 440/50 -46
Dimensions - see Page B42 550-600/60 or 550/50 -56
200-208/60 -86
AC 2 Speed Starters with Magnetic Trip Circuit Breaker, 200, 230, 460 and 575V
2 Speed, Single Winding (consequent pole), Bulletin 6060
Maximum Motor
Horsepower Rating Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Constant or Variable Torque Continuous Breaker GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA ( Constant Horsepower) Ampere Ampere Enclosure Enclosure
1 1
Size 200V 230V 460V/575V Ratings Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 1/2 1
1 18 3 T60AA0C2671 - * 3540. - use size 1 - - use size 1 -
1
( /4 ) ( /3 ) (1)
1 1
1 /2 1 /2 3
0 18 7 T60AA0C2672 - * 3540. - use size 1 - - use size 1 -
( 3/4 ) (1) (2)
3 3 5
18 15 T60AA0C2673 - * 3540. - use size 1 - - use size 1 -
(2) (2) (3)
1
1
/2 1
/2 1 /2
27 3 T60AA1C2671 - * 3684. T60WA1C2671 - * 5652. T60TA1C2671 - * 4080.
( 1/4 ) ( 1/3 ) (1)
1 1
1 /2 1 /2 3
3
/4 )
27 7 T60AA1C2672 - * 3684. T60WA1C2672 - * 5652. T60TA1C2672 - * 4080.
1 ( (1) (2)
3 3 5
27 15 T60AA1C2673 - * 3684. T60WA1C2673 - * 5652. T60TA1C2673 - * 4080.
(2) (2) (5)
1 1
7 /2 7 /2 10
27 30 T60AA1C2674 - * 3684. T60WA1C2674 - * 5652. T60TA1C2674 - * 4080.
(5) (5) (7 1/2 )
1 1
7 /2 7 /2 10
45 30 T60AA2C2674 - * 5688. T60WA2C2674 - * 7992. T60TA2C2674 - * 6312.
2 (5) (5) (7 1/2 )
10 15 25
45 50 T60AA2C2675 - * 5688. T60WA2C2675 - * 7992. T60TA2C2675 - * 6312.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T60AA3C2676 - * 7716. T60WA3C2676 - * 11652. T60TA3C2676 - * 9084.
(20) (25) (40)
40 50 100
4 135 150 T60AA4C2677 - * 18720. T60WA4C2677 - * 24816. T60TA4C2677 - * 22536.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)
Note:
1. Includes starter complete with N.O. contact, on each contactor, and two 3 phase overload relays less heaters. All starters
are mechanically and electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
3
8
0
AC 2 Speed Starters with Magnetic Trip Circuit Breaker, 200, 230, 460 and 575V
2 Speed, Double Winding (Separate Winding), Bulletin 6060
Maximum Motor
Horsepower Rating Starter Circuit NEMA Type 1 NEMA Type 4 NEMA Type 12
Constant or Variable Torque ( Continuous Breaker GeneralPurpose Watertight Enclosure Industrial - Dust-tight
NEMA Constant Horsepower) Ampere Ampere Enclosure Enclosure
1 1 1
Size 200V 230V 460V/575V Rating Ratings Catalog No. Price Catalog No. Price Catalog No. Price
1
/2 1
/2 1 1/2
1 1 18 3 T60AA0S2671 - * 3012. - use size 1 - - use size 1 -
( /4 ) ( /3 ) (1)
1 1/2 1 1/2 3
0 18 7 T60AA0S2672 - * 3012. - use size 1 - - use size 1 -
( 3/4 ) (1) (2)
3 3 5
18 15 T60AA0S2673 - * 3012. - use size 1 - - use size 1 -
(2) (2) (3)
1 1
/2 /2 1 1/2
27 3 T60AA1S2671 - * 3180. T60WA1S2671 - * 5028. T60TA1S2671 - * 3576.
( 1/4 ) ( 1/3 ) (1)
1 1/2 1 1/2 3
27 7 T60AA1S2672 - * 3180. T60WA1S2672 - * 5028. T60TA1S2672 - * 3576.
1 ( 3/4 ) (1) (2)
3 3 5
27 15 T60AA1S2673 - * 3180. T60WA1S2673 - * 5028. T60TA1S2673 - * 3576.
(2) (2) (5)
7 1/2 7 1/2 10
27 30 T60AA1S2674 - * 3180. T60WA1S2674 - * 5028. T60TA1S2674 - * 3576.
(5) (5) (7 1/2 )
7 1/2 7 1/2 10
1
/2 )
45 30 T60AA2S2674 - * 4728. T60WA2S2674 - * 7056. T60TA2S2674 - * 5352.
2 (5) (5) (7
10 15 25
45 50 T60AA2S2675 - * 4728. T60WA2S2675 - * 7056. T60TA2S2675 - * 5352.
(7 1/2 ) (10) (20)
25 30 50
3 90 100 T60AA3S2676 - * 6420. T60WA3S2676 - * 10356. T60TA3S2676 - * 7788.
(20) (25) (40)
40 50 100
4 135 150 T60AA4S2677 - * 14352. T60WA4S2677 - * 20478. T60TA4S2677 - * 18168.
(30) (40) (75)
75 100 200
5 270 400 Consult Factory
(60) (75) (150)
Note:
1. Includes starter complete with N.O. contact, on each contactor, and two 3 phase overload relays less heaters. All starters
are mechanically electrically interlocked. Six (6) heaters are required, 3 heaters for each speed.
4
8
5
Wye-Delta Starters
Available Open or Closed Transition
Inrush Current 1/3 Normal Line Starting
NEMA 1 Enclosure Standard
3
8
0
B25
TM - NEMA Control Reduced Voltage Starters
Autotransformer Closed Transition - Bulletin 6082
Max. Motor NEMA Type 1
2
Horsepower GeneralPurpose
NEMA Rating 1
Size 230V 460V Catalog No. Price
25 ----- T82AA3FB - * 9714.
30 ----- T82AA3GB - * 9714.
3
T82AA3GE - *
B -----
-----
30
50 T82AA3JE - *
10788.
10788.
50 ----- T82AA4JB - * 15516.
4
----- 100 T82AA4ME - * 15804.
75 ----- U2AA5LB - * 24690.
100 ----- U82AA5MB - * 26560.
5
----- 150 U82AA5PE - * 26690.
----- 200 U82AA5QE - * 28890.
125 -----
150 -----
200 -----
6 Refer to Section A
----- 250
----- 300
----- 400
Note:
1. Maximum horsepower ratings are in accordance with NEMA Standards ICS2-321C:20. Auto transformers are 3-Coil type, with voltage taps at
50%, 65% and 80% rated in accordance with NEMA Standards ICS2-214.21 for medium-duty starting service.
0
2. Size 5 Starters are supplied in floor mounted enclosures without bottom cover plate for mounting against a wall. If not mounted against a wall, a 3
rear cover plate must be ordered. 3
3. Wye-Delta Starters Overload Relay Heater Selected by dividing FLC by 1.73 and select Heaters from index.
Note:
Includes starter complete with two contactors, timing device Overload Realy Heater Data
and two overload relays less heaters. (6 are required) Heater elements should be selected for running current in each
These starters are usually used with wye(star) connected winding. A total of 6 heater elements are required per controller.
motors. They may also be used for delta connected motors
when the motors are so designed that neither delta winding
need be open during starting.
4
0
0
Ordering Information Coil Volt/Hertz Suffix
Use complete catalog number. Replace the Modifications see Page B36 24/60 or 24/50 -96
(*) with the suffix from the coil table. Renewal Parts see Page B50 110-120/60 or 110/50 -76
Order heater elements at $18 each. Engineering Data see Page B42 220-240/60 or 220/50 -26
440-480/60 or 440/50 -46
550-600/60 or 550/50 -56
200-208/60 -86
1
5 7 1/2 3 3 27 30
30 K18RB31203 - * $ 1530.
7 1/2 ----- ----- 7 1/2 60 K18RB31206 - * 1554.
2
10 15 ----- ----- 45 60
60 K18RB32206 - * 2070.
----- ----- 10 15 100 K18RB32201 - * 2214.
3
25 30 ----- ----- 90 100
100 K18RB33201 - * 3342.
----- ----- 25 30 200 K18RB33202 - * 3618.
4 40 50 ----- ----- 135 150 200 K18RB34202 - * 6258.
----- ----- 40 50 400 K18RB34204 - * 6846.
5 75 100 50 60 270 400 400 VK18RB350694 - * 13722.
Note:
1. Includes Pump Control Panel in NEMA 3R weather-resistant enclosure, complete with integral circuit breaker or fusible
disconnect switch less fuses, start push button. Hand-Off-Auto selector switch and 3 phase ambient compensated overload
relay less heaters. Heaters are purchased separately at $9 each. For non ambient compensated overload relay delete "J"
4
from coil suffix. 8
5
1
52
5 2
----- 27
40 K20RB31203 - * $ 1580.
7 1/2 7 1/2 ----- 50
TEB K20RB31204 - * 1580.
2
10 10 ----- 45
50 K20RB32204 - * 2094.
----- 15 ----- 70 K20RB32205 - * 2094.
3
25 25 ----- 90
100 K20RB33206 - * 3462.
25 30 ----- 150
TED K20RB33208 - * 3462.
4 40 40 ----- 135 K20RB34028 - * 7362.
150
----- 50 ----- TEC K20RB34677 - * 7362.
Note:
1. Includes Pump Control Panel in NEMA 3R weather-resistant enclosure, complete with integral circuit breaker or fusible disconnect switch
less fuses, start push button. Hand-Off-Auto selector switch and 3 phase ambient compensated overload relay less heaters. Heaters are
purchased separately at $9 each.
The rated full load current shown on the motor nameplate is likely to vary from the values listed below .
The NAMEPLATE full load current should always be used in determining the rating of devices.
When using a design "E" Motor Special considerations apply refer to NEC 1996 tables 430 -151A & B & 430-152, page 70-453/454.
B
FULL-LOAD MOTOR-RUNNING CURRENTS IN AMPERES
CORRESPONDING TO VARIOUS A.C. HORSEPOWER RATINGS
115 Volts 230 Volts 1 , 2 380 Volts 460 Volts 575 Volts 2.3 KV 4.16 KV
Single Three Single Three Single Three Single Three Single Three Three Three H.P.
Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase Phase
1/10 -- -- -- -- -- -- -- -- -- -- -- --
1/8 -- -- -- -- -- -- -- -- -- -- -- --
1/6 4.4 -- 2.2 -- 1.40 -- -- -- -- -- -- --
1/4 5.8 -- 2.9 -- 1.85 -- -- -- -- -- -- --
1/3 7.2 -- 3.6 -- 2.32 -- -- -- -- -- -- --
1/2 9.8 4.4 4.9 2.2 3.19 1.28 2.5 1.1 2.0 0.9 -- --
3/4 13.8 6.4 6.9 3.2 4.47 1.78 3.5 1.6 2.8 1.3 -- --
1 16.0 8.4 8.0 4.2 5.12 2.30 4.0 2.1 3.2 1.7 -- --
1.5 20.0 12.0 10.0 6.0 6.38 3.32 5.0 3.0 4.0 2.4 -- --
2 24.0 13.6 12.0 6.8 7.66 4.34 6.0 3.4 4.8 2.7 -- --
3 34.0 -- 17.0 9.6 10.87 6.14 8.5 4.8 6.8 3.9 -- --
5 56.0 -- 28.0 15.2 17.90 9.71 14.0 7.6 11.2 6.1 -- --
7.5 80.0 -- 40.0 22.0 26.80 14.00 21.0 11.0 16.0 9.0 -- --
10 100.0 -- 50.0 28.0 33.20 17.90 26.0 14.0 20.0 11.0 -- --
15 -- -- -- 42.0 -- 26.80 34.0 21.0 27.0 17.0 -- --
20 -- -- -- 54.0 -- 34.50 44.0 27.0 35.0 22.0 -- --
25 -- -- -- 68.0 -- 43.50 55.0 34.0 44.0 27.0 -- --
30 -- -- -- 80.0 -- 51.20 68.0 40.0 54.0 32.0 -- --
40 -- -- -- 104.0 -- 66.50 88.0 52.0 70.0 41.0 -- --
50 -- -- -- 130.0 -- 83.10 108.0 65.0 86.0 52.0 -- --
60 -- -- -- 154.0 -- 103.0 -- 77.0 -- 62.0 16. 9.
75 -- -- -- 192.0 -- 128.0 -- 96.0 -- 77.0 20. 11.
100 -- -- -- 248.0 -- 165.0 -- 124.0 -- 99.0 26. 14.3
125 -- -- -- 312.0 -- 208.0 -- 156.0 -- 125.0 31. 17.
150 -- -- -- 360.0 -- 240.0 -- 180.0 -- 144.0 37. 20.
200 -- -- -- 480.0 -- 320.0 -- 240.0 -- 192.0 49. 27.
250 -- -- -- -- -- 403.0 -- 302.0 -- 242.0 60. 33.
300 -- -- -- -- -- 482.0 -- 361.0 -- 289.0 72. 40.
350 -- -- -- -- -- 560.0 -- 414.0 -- 336.0 83. 46.
400 -- -- -- -- -- 636.0 -- 477.0 -- 382.0 95. 52.
500 -- -- -- -- -- 786.0 -- 590.0 -- 472.0 118. 65.
5
NOTES:
1. To obtain F.L.C. for 200 and 208 Volt motors multiply 230 volts values by 1.15 and 1.10 respectively.
2. To obtain F.L.C. for 265 and 277 Volt motors multiply 230 Volt values by .87 and .83 respectively.
B35
TM - NEMA Control Factory Modifications
Modifications
Cover Controls
Enclosure Type
Add to NEMA
For Type Change
Bulletin Type Letter To:
Number Size 1 4 12 Typical Catalog Number
Power Circuit
TECL Current Limiter Attachment for TEC 6020-40,
360. 360. 360. 960. 1950. N/A 45
Motor Circuit Protectors, 100,00 AIC Max. 6060
Class J Fuse Clips, In place of Class H 1,4,12
6018-38 9
Class R Fuse Clips, In place of Class H 6058 N/C N/C N/C N/C N/C N/C
Control transformer1
Description
Standard Capacity
Primary Volts/Hertz:
220-240/60, or 220/50 -T26
440-480/60, or 440/50 324. 324. 456. 672. 816. 924. -T46
550-600/60, or 550/50 -T56
200-208/60 -T86
372. 372. 612. 876. 1116. 1284. -T35
380/50
220/252 -T22
492. 492. 684. 1008. 1224. 1224.
440/252 -T42
100 Watts Extra
All 1,4,12
Primary Volts/Hertz:
220-240/60, or 220/50 -C26
440/480/60, or 440/50 -C46 T18AA31603-T46
550-600/60, or 550/50 576. 576. 744. 936. 1056. 1176. -C56
200-208/60 -C86
280/50 -C35
220/252 -C22
440/252 864. 864. 1116. 1404. 1584. 1764. -C42
Fused Primary (Includes 2 Fuses)
112. 112. 112. 112. 112. 112. 47
Ungrounded Secondary with 2 Dual
N/C N/C N/C N/C N/C N/C 48
ElementFuses
5
1 Special Voltage on Transformer (Not Std.)
2
Dual Voltage Secondary Add 10% to Price of Transformer 49
Notes:
UL Listed for field modification. Other modifications listed factory installed.
1. Single or Dual (200-240 & 440-480) Voltage primary with 110-120V secondary. Standard primary
voltages are 110-120, 200-205, 220-240, 277, 380, 440-480 and 550-600. Prices included 1 panel-
mounted, dual-element secondary fuse, with other side of secondary connected to cabinet ground.
2. Price includes extra-wide enclosure when used with any Bulletin 6018-20 starter.
Auxiliary Devices
T 82 A A 4JB—26
Control Relay (4 pole max.) NEMA 1 & 12 Encl. 612. 612. 612. 82
NEMA 4 Enclosure 936. 936. 936. 83
Pneumatic Timing Relay (3 min. max.) NEMA 1 & 12 Encl. 1008. 1008. 1008. 84
NEMA 4 Encl. 1320. 1320. 1320. 85
3 Phase Voltage Monitor Relay NEMA 1;4, & 12 Encl. 1152. 1152. 1152. 87
(Phase loss, Phase reversal, &
Undervoltage)
Ammeter & 1-Current Transformer 1680. 2376. 2376. 88
Ammeter, Switch & 3-Current Transformer 4440. 4440. 4440. 89
Voltmeter 2376. 2376. 2376. 90
Voltmeter & Switch NEMA 1,4 & 12 Encl. 3600. 3600. 3600. 91
Elasped Time Meter 696. 696. 696. 92
Wattmeter 4864. 4864. 4864. 93
Watthour meter 5040. 5040. 5040. 94
Convenience Recepticle Mounted on Side 240. 240. 240. 95
Cylinder Lock on Door 600. 600. 600. 96
Space Heater with N.C. Auxiliary
NEMA 1,4 & 12 Encl. 924. 1488. 2208. 97
Notes:
1. For Bulletins 6018, 6020, 6038, 6040, 6058, & 6060, NEMA 4 & 12 enclosed, use 30 mm. units.
2. Kits may be changed in the field from 3-position to 2-position operation. In addition to HAND-OFF-AUTO,
four labels are included, marked: FORWARD-OFF-REVERSE; HIGH-OFF-LOW; TEST-LAG-HEAD; ON-OFF.
3. Not suitable for enclosed starters with transformer.
VA Primary
Capacity Voltage Hertz Bulletin No. NEMA Size Kit Number Price
Standard 208 KTR67-16 $ 216.
Capacity - 50 240 & 480 KTR67-2 216.
Note: KTR67-12
600 5 216.
Can be used in NEMA 1, 4 & 12 00-2
100VA Extra 208 KTR67-20 264.
enclosures that have available space. See
Capacity - 150 240 & 480 50/60 All KTR67-5 264.
enclosure kits to determine those with
600 (See Note KTR67-22 264.
available space.
Standard 208 at Left) KTR67-23 342.
Capacity - 250 240 & 480 3&4 KTR67-7 342.
600 KTR67-25 342.
Accessories
6018-20-38,
Fuse Block, 2 Pole, 30 Amp., 250V, Class H, with two 1/2 Amp. Dual Element Fuses. 6040-58-60 0-2 KTM2-1 72.
Universal Starter Adaptor Kit. NEMA Size 1 Type TM starter with an assortment of 4
heaters, auxiliary contacts, and coils and A60-300999 adaptor plate. For rush and All 00-1 KTM-USA 1584.
9
2
emergency repairs; can replace most NEMA Size 00-1 starters
Notes:
1. For use with the listed open type devices. Each kit includes external "Reset" button(s) 2. Does not have space for transformer.
and "Reset" plug(s), either of which may be installed in the predrilled enclosure cover. 3. External "Reset" not included. For external "Reset", add Kit Number KTM32-20.
All enclosures have sufficient space to allow mounting a transformer or other equip- 4. Will not fit standard enclosures.
ment of similar size, unless otherwise noted. 5. Not applicable to NEMA 1 - Bulletin 6018, 6038 & 6058
Fuse Clips - Kit includes 6 clips and mounting screws,without base for lower clips. Bulletin No. NEMA Size Kit No. Kit No. Price
Fuse Switch If unit was If unit was
purchasedafter purchasedbefore
Class Amp. Size 1/1/98 1/1/98
30 amp. 250 volt (incl. 3 adaptor plates) H 0-2 KTMF-332* KTMF-332 $ 48.
30 amp. 600 volt & 60 amp. 250 volt H&J 30 & 60 KTMF-336* KTMF-336 48.
6018-38-58 KTMF-366* KTMF-366
60 amp. 600 volt H&J 1&2 72.
1 & 2 KTMF-312* KTMF-312
100 amp. 250 volt & 600 volt H 60 & 100 2&3 120.
Fuse Clip Lower Mounting Base - required only when converting a non-fusible starter to fusible or when
changing from 60 to 100 amp.30 & 60 amp. 250 & 600V 6018-38-58 2&3
2&3
00-2 KTMF-036*
KTMF-061*
KTMF-036
KTMF-061
60. B
00-2 96.
100 amp. 250 & 600 volt
* Add series letter from catalog # on the label on the door of Enclosure Series “A”, “B” or “C” A 2&3
Heater Rack - Designed for stocking heaters for all TM starters. Rack has 25
compartments and will hold 900 of the #2400 series heaters or 600 of the #2500 ---- ---- KTM-99 390.
series heaters or a combination there of.
Power Contact Kit, For Type TM Normally Open Auxillary Side-mounted Power Pole on 1 & 2 0&1 KTM31-2 87.
Pole Starters And Contactors (1 Kit Required Per Pole-Movable And Stationary Contacts & 1P &2 KTM32-2 122.
Springs) 3 KTM43-1 345.
4 KTM44-1 1035.
Power Contact Kit, For Normally Closed Type TM Auxillary Side-mounted Power Pole 0,1,1P &2 KTM32-17 104.
(Movable And Stationary Contacts & Springs) 3 KTM43-2 345.
4 KTM44-2 1035.
Power Contact Kit, For Type TM Auxillary Side-mounted Tie Pole 2 REQD. 0&1 KTM32-17 $ 97.
(Movable And Stationary Contacts & Springs 1 REQD. 2 KTM32-18 221.
2 REQD. 3 KTM53-1 690.
2 REQD. 4 KTM54-1 2070.
Arc Shield Cover Kit (1 Required Per Power Pole) TM6 6 A77-434905A 863.
Replacement Overload Relay, Standard Bimetallic, Less Heaters, For Single Phase Type TM 00,0,1&1P KTM31-14 62.
Starter. Non Ambient Compensated
4
Coil Part Numbers For Volts/Hertz
1
NEMA 110-120 200-208 220-240 277 380 440-480 550-600
Size Poles 110 220 440 550 Price
00-2 2-4 TB159-1 TB159-10 TB159-2 TB159-13 TB159-11 TB159-3 TB159-4 $ 124.
3 2-4 TB162-7 TB162-14 TB162-8 TB162-13 TB162-15 TB162-9 TB162-10 207.
4 2-4 TB162-1 TB162-16 TB162-2 TB162-18 TB162-17 TB162-3 TB162-4 248.
5 T Series 2-3 TB161-1 TB161-5 TB161-2 TB161-12 TB161-10 TB161-3 TB161-4 483.
61 T Series 2-3 TB163-1 TB163-5 TB163-2 TB163-7 TB163-6 TB163-3 TB163-4 476.
5 U Series 2-3 335L1 ————— 335L2 ————— ————— 335L3 335L4 225.
6 V Series Refer to Section A
15
/16
/16
3 3/4
3 3/4
1
1
1
1
/2
/2
B
7
3-4 2-3 5 /16 8 1/8 7 1
/16 6 7/8 3 1
/2
3-4 4 6 15/16 8 1/8 7 1
/16 6 7/8 3 1
/2
3
5 2-3 8 /4 12 1/4 9 1
/2 11 1/2 7
6 See Section A
NEMA Type 1
Type 1
00 3 6 3/4 9 1/2 6 1/4 7 3/4 5
0-2 1-4 6 3/4 9 1/2 6 1/4 7 3/4 5
3-4 2-4 12 22 9 19 9
5 2-3 22 49 11 3/8 47 1/2 18
6 See Section A
Type 1 (with transformer)
00 3 12 5/8 9 1/2 6 1/4 7 3/4 11
5 1 1
0-2 1-4 12 /8 10 /8 6 /4 9 1/2 11
3-4 2-4 12 22 9 19 9 NEMA Type 4
5 2-3 22 49 11 3/8 47 1/2 18
6 See Section A
Type 4
00 3 7 1/4 11 6 7/8 10 1/2 41
0-1 1-4 7 1/4 11 6 7/8 10 1/2 41
1 7
2 2-4 7 /4 11 6 /8 10 1/2 41
1 5 3
3 2-4 12 /4 24 /8 9 /16 23 1/2 71
1 5 3
4 2-4 12 /4 24 /8 9 /16 23 1/2 71
3
5 2-3 17 49 11 /8 47 1/2 18
6 See Section A
Type 4 (with transformer)
NEMA Type 12
1 7 1
00 3 13 /8 11 6 /8 10 /2 6
1 7 1
0-1 1-4 13 /8 11 6 /8 10 /2 6
1 7 1
2 2-4 13 /8 11 6 /8 10 /2 6
1
3 2-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
1
4 2-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
3 1
5 2-3 17 49 11 /8 47 /2 18
6 See Section A
Type 12
00 3 7 1/4 11 6 15
/16 10 1/2 41
0-2 1-4 7 1/4 11 6 15
/16 10 1/2 41
1 5 3
3-4 2-4 12 /4 24 /8 9 /16 23 1/2 71
3
5 2-3 22 49 11 /8 47 1/2 18
6 See Section A Conduit Hub Size and Location
Type 12 (with transformer) Enclo. Top & Bottom
Size Bottom Only H J K
00 3 13 1/8 11 6 15/16 10 1
/2 6 3
/4 3
/4 3 1 5/8 1 5/8
00-1
0-2 1-4 13 1/8 11 6 15/16 10 1
/2 6 3
/4 3 1 5/8 1 5/8
2 1 1/2
3-4 2-4 12 1/4 24 5/8 9 3/16 23 1
/2 71 3
/4 3 2 2
3 2
5 2-3 22 49 11 3/8 47 1
/2 18
4 2 1/2 3
/4 3 2 2
6 See Section A 5 3 3
5 3 3
/4
1
One top mtg. keyhole on center line.
B43
TM - NEMA Control Dimensions
NEMA Open Type, Type 1, 4 & 12
Open Type Dimensions - inches AC Magnetic Starters
NEMA Wide High Deep Mounting
Size Poles A B C D E Open Type Size 5
7
00 2-3 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
0-1 1-3 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
0-1 4 4 /8 6 5 3/16 5 1
/2 2 1
/2
7
1P 2 3 /8 6 5 3/16 5 1
/2 2 1
/2
7
2 2-3 3 /8 6 5 3/16 5 1
/2 2 1
/2
B 2
3-4
4
3
4
5
7
/16
15
/16
6
11
5 3/16
7 1/16
5
9
1
3
/2
/4
2
3
1
1
/2
/2
7
3-4 4 6 /8 11 7 1/16 9 3
/4 3 1
/2
1
5 3 10 /8 15 7/8 9 5/8 13 1
/2 6 3
/8
6 See Section A
Type 1
00 2-3 6 3/4 9 1/2 6 1/4 7 3
/4 5
0-2 2-4 6 3/4 9 1/2 6 1/4 7 3
/4 5
1P 2 6 3/4 9 1/2 6 3/4 7 5
3-4 3-4 12 22 9 19 9
5 3 72 49 11 3/8 47 1
/2 18 NEMA Type 1 — Size 5
6 See Section A NEMA Type 1 — Sizes 00 to 4
Type 1 (with transformer)
5
00 2-3 12 /8 9 1/2 6 1
/4 7 3
/4 11
5 1 1 1
0-2 2-4 12 /8 10 /8 6 /4 9 /2 11
5
1P 2 12 /8 10 1/8 6 1/4 9 1
/2 11
3-4 3-4 12 22 9 19 9
5 3 22 49 11 3/8 47 1
/2 18
6 See Section A
Type 4
1 7 1
00 2-3 7 /4 11 6 /8 10 /2 41
1 7 1
0-1 2-4 7 /4 11 6 /8 10 /2 41
1 7 1
1P 2 7 /4 11 6 /8 10 /2 41
1 7 1
2 3-4 7 /4 11 6 /8 10 /2 41
1
3 3-4 12 /4 24 5/8 9 3
/16 23 1
/2 71
1
4 3-4 12 /4 24 5/8 9 3/16 23 1
/2 7 NEMA Type 4 NEMA Type 12
5 3 17 49 11 3/8 47 1
/2 18
6 See Section A
Type 4 (with transformer)
1
00 2-3 13 /8 11 6 5/16 10 1
/2 6
1
0-2 2-4 13 /8 11 6 5/16 10 1
/2 6
1
1P 2 13 /8 11 6 5/16 10 1
/2 6
1
2 3-4 13 /8 11 6 5/16 10 1
/2 61
1
3 3-4 12 /4 24 5/8 9 3/16 23 1
/2 71
1 5
4 3-4 12 /4 24 /8 9 3/16 23 1
/2 7
5 3 17 49 11 3/8 47 1
/2 18
6 See Section A
Type 12
1
00 2-3 7 /4 11 6 15/16 10 1/2 41
1
0-2 2-4 7 /4 11 6 15/16 10 1/2 41
1
1P 2 7 /4 11 6 15/16 10 1/2 41 Conduit Hub Size and Location
1
3-4 3-4 12 /4 24 5/8 9 3/16 231/2 7 4
5 3 22 49 11 3/8 47 1/2 18 Enclo. Top & Bottom 9
2
6 See Section A Size Bottom Only H J K
3 3
00-1 /4 /4 3 1 5/8 1 5/8
Type 12 (with transformer)
2 1
1 /2 3
/4 3 1 5/8 1 5/8
1
00 2-3 13 /8 11 6 15/16 10 1
/2 6 3 2 3
/4 3 2 2
1
0-2 2-4 13 /8 11 6 15/16 10 1
/2 6 4 2 1/2 3
/4 3 2 2
1
1P 2 13 /8 11 6 15/16 10 1
/2 61 5 3 3 5 3 3
1 5
/4
3-4 3-4 12 /4 24 /8 9 3/16 23 1
/2 7
5 3 22 49 11 3/8 47 1
/2 18 Note:
6 See Section A 1. One top mtg. keyhole on center line.
B44
TM - NEMA Control Dimensions
NEMA Open Type, Type 1, 4 & 12 Reversing Starters & Contactors
Open Type Dimensions - inches
NEMA Wide High Deep Mounting
Size Poles Fig. A B C D E E1
00 3 8 3/16 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
0-1 3 8 3/16 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
0-1 4 9 3/116 4 1/4 4 3/4 3 3/4 6 13/16 4 5/16
2
2
3
4 1
8 3/16
9 3/16
4 1/4
4 1/4
4 3/4
4 3/4
3 3/4
3 3/4
6 13/16
6 13/16
4 5/16
4 5/16
B
3-4 3 11 5/16 8 1/8 7 1/16 6 7/8 9 3/8 5 7/ 8
3-4 4 14 15/16 8 1/8 7 1/16 6 7/8 9 3/8 5 7/8
5 3 19 3/4 16 1/4 10 1/8 15 1/2 17 1/16
5 3 Starter Refer Factory
6 See Section A
Type 1 Contactors and Starters
5
00 3 5 12 /8 9 1/2 6 1/4 7 3/4 11 *
5
0-2 3-4 5 12 /8 9 1/2 6 1/4 7 3/4 11 *
1
3-4 3-4 5 18 /2 25 3/4 9 23 16 16
5 3 6 22 49 9 3/8 47 1/2 18
6 See Section A
Type 1 (with transformer) Contactors and Starters
00 3 13 1/8 11 6 7/8 10 1
/2 6 6
1
0-2 3-4 13 /8 11 6 7/8 10 1
/2 6 6
3 3-4 18 3/4 28 3/8 9 3/16 27 1
/4 13 13
3 3
4 3-4 7 18 /4 28 /8 9 3/16 27 1
/4 13 13
5 3 25 37 1/2 10 1/2 36 11
6 See Section A
Type 4 (with transformer) Contactors and Starters
7
00 3 8 17 13 6 /8 9 16 16
7
0-2 3-4 8 17 13 6 /8 9 16 16
3 3-4 7 18 3/4 28 3/8 9 3
/16 27 1/4 13 13
4 3-4 7 18 3/4 28 3/8 9 3
/16 27 1/4 13 13
5 3 7 25 37 1/2 10 1
/2 36 11
6 See Section A
Type 12 Contactors and Starters
1
00 3 13 /8 11 6 15/16 10 1
/2 6 6
1
0-2 3-4 13 /8 11 6 15/16 10 1
/2 6 6
3
3-4 3-4 7 18 /4 23 3/8 9 3/16 27 1
/2 13 13
5 3 22 49 11 3/8 47 1
/2 18
6 See Section A Steel Enclosure
Type 12 (with transformer) Contactors and Starters NEMA Type 12 — No Hub Provisions
7
00 3 8 17 13 6 /8 9 6 6
0 7
0-2 3-4 8 17 13 6 /8 9 6 6
1
3-4 3-4 7 18 3/4 28 3/4 9 3
/16 27 1/4 13 13 Conduit Hub Size and Location
3
5 3 7 22 49 11 3
/8 47 1/2 18 Enclo. Top & Bottom
6 See Section A Size Bottom Only H J K
3 3
00-1 /4 /4 3 1 /85
1 5/8
2 1 1/2 3
/4 3 1 5/8 1 5/8
Note:
3 2 3
/4 3 2 2
1. One top mtg. keyhole on center line.
4 2 1/2 3
/4 3 2 2
5 3 3
/4 5 3 3
B45
TM - NEMA Control Dimensions
AC Non-Reversing 2 Speed Starters
Dimensions-Inches Mounting
NEMA Wide High Deep
Open Type
Size Fig. A B C D E1 E F
Open type - 2 Speed, Single Winding
00-2 1 9 3/16 6 5 5/16 5 1/2 4 5/16 6 3/16 1
/4
3-4 13 5/16 11 7 1/16 9 3/4 5 7/8 9 3/8 5
/16
B Open type - 2 Speed, Double Winding
Notes:
1. Indicates mounting hole is on the center line of enclosure.
2. For NEMA size 5 refer to factory.
3. NEMA Type 4 includes conduit hubs. NEMA Type 12-No Hub Provisions
B46
Dimensions NEMA Control - TM
Combination Starters
Compact Style
Standard or Extra-Wide Style NEMA 1
NEMA 1 Conduit
Standard or Extra-Wide Style
Hub
NEMA 4 & 12
NEMA 4 Hub
Application Table
Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
2 1 1/4 3
/4 & 1 1/4 Conduit
3 2 3
/4 & 2 Compact Style Hub
4 2 1/2 3
/4 & 2 1/2 NEMA 4 & 12
NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
1
Standard 87/8 261/2 7 3
/4 24 4 1
/2 19/32 11 11
/32
Consult Factory 7 1 1 11
0-2 Compact 15 13 6 /8 11 10 /2 1 11 /32
3
Extra-Wide 157/8 261/2 7 3
/4 24 11 1/2 11 1
/2 1 11 11
/32
3 Standard 14 35 3/8 8 7
/8 33 9 1/2 9 1
/2 1 1/4 13 11
/32
3
3 Extra-Wide 22 35 3/8 8 7
/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7
/8 37 16 16 1 1/4 13 11
/32
7
5 Standard 22 49 9 /8 47 1/2 18 18 1 5/8 14 1/4 7
/16
B47
TM - NEMA Control Dimensions
Combination Reversing Starters
NEMA 4 Hub
Application Table
Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
1 3
2 1 /4 /4 & 1 1/4
3
3 2 /4 & 2
4 2 1/2 3
/4 & 2 1/2
NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 26 1/2 7 3/4 24 11 1/2 11 1/2 1 11 11
/32
3 Standard 22 35 3/8 8 7/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7/8 37 16 16 1 1/4 13 11
/32
5 Contact factory
NEMA 4 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G H J K L M Diameter
7 9 3 13 1 1 3
0-2 Standard 15 /8 28 /16 7 /4 27 /16 11 /2 11 /2 /8 11 5
3 /32 1 /21
3 — — 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
5 Contact factory
NEMA 12 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 3
/8 3
/8 11 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 11
/32
5 Contact factory
B48
Dimensions NEMA Control - TM
Combination 2 Speed
NEMA 4 Hub
Application Table
Dimensions-Inches
NEMA Top Bottom
Size Hub Hub
3 3
0&1 /4 /4
2 1 1/4 3
/4 & 1 1/4
3
3 2 /4 & 2
4 2 1/2 3
/4 & 2 1/2
NEMA 1 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 26 1/2 7 3/4 24 11 1/2 11 1/2 1 11 11
/32
3 Standard 22 35 3/8 8 7/8 33 16 16 1 1/4 13 11
/32
4 Standard 22 39 3/8 8 7/8 37 16 16 1 1/4 13 11
/32
5 Contact factory
NEMA 4 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G H J K L M Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 11 1/2 3
/8 11 5
3 /32 1 /21
3 — — 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 7
/8 13 2 3/4 1 1/2 4 — — 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 2 3/4 1 1/2 4 — — 11
/32
5 Contact factory
NEMA 12 Enclosures
Dimensions- Inches Mounting
NEMA Cabinet Wide High Deep Mounting Hole
Size Style A B C D E1 E F G Diameter
0-2 Standard 15 7/8 28 9/16 7 3/4 27 13/16 11 1/2 3
/8 3
/8 11 11
/32
3 Standard 22 37 1/2 8 7/8 36 3/4 16 16 3
/8 13 11
/32
4 Standard 22 41 1/2 8 7/8 40 3/4 16 16 3
/8 13 11
/32
5 Contact factory
B49
TM - NEMA Controls Engineering Data
Ratings - Controllers - Type TM
Continuous ampere and maximum horsepower ratings are
in accordance with the following NEMA Standards:
Starters ICS 2-32 1B, ICS 2-321F
Contactors ICS 2-211.23, ICS 2-211.24
1
For aluminum (Al) load wiring accommodations on Size 00-4, refer to local sales office.
2
Devices are equipped with one (1) lug p[er phase, except size 6.
3
UL specifies only one (1) wire per lug.
Control Circuit Contact & Coil Terminals - Type TM
B50
Dimensions NEMA Controls - TM
Control Transformer Sizes
Coil Burden - Type TM For Type TM A-C Contactors Or Starters
5 This Table applies to contactors used to switch the load at the utilization voltage of the heat-
producing elements with a duty which requires continous operation of not more than five (5)
openings per minute.
B51
TM - NEMA Controls Engineering Data
For Starters 6013-TM;
Contactors 7707-TM Non-Combination
Separate Control
Remove wire "A" when it is supplied.
Connect separate control lines to the
"1" terminal on the pilot device and
the "4" terminal on the starter.
Coil Terminal wire to be #14 AWG
maximum.
B52
Engineering Data NEMA Controls - TM
For Starters 6030-TM;
Contactors 6031-TM
B53
TM - NEMA Controls Engineering Data
For Starters 6050-TM
B54
Engineering Data NEMA Controls - TM
For Starters 6050-TM
Wiring Diagram Front View
Elementary Diagram
Motor Pushbotton A B C D E F M1 M2
Figure 1 Figure 2 T6 T4 T5 T1 T2 T3 Low High
Figure 2 Figure 1 T1 T2 T3 T6 T4 T5 High Low
Figure 3 Figure 1 T1 T2 T3 T6 T4 T5 High Low
B55
TM - NEMA Controls Engineering Data
For Starters 6018-TM, 6020-TM Combination
Voltage Connect L1 L2
B 230
H1 to H3
H2 to H4
H1 H4
460 H2 to H3 H1 H4
All Single H1 H2
Primary Transformers
B56
Engineering Data NEMA Controls - TM
Voltage Connect L1 L2
H1 to H3 H1 H4
230
H2 to H4
460 H2 to H3 H1 H4
All Single H1 H2
Primary Transformers
B57
TM - NEMA Controls Engineering Data
Standard A-C Wiring Diagrams
Two-Speed, Two Winding (Separate Winding)
B
Two Speed
Two Winding
Motor
Contactors
"HI" and "LO" are
Mechanically
Interlocked
When control circuit obtains power Remove wire "A" when it is supplied.
from the line side of the starter as Connect separate control lines as
shown, and control conductors follows:
extend beyond the enclosure, they With internally mounted fuses,
must have overcurrent protection connect to fuse block.
rated not in excess of 500% of the Without internal fuses, an external
control circuit conductor ampacity. fuse must be mounted immediately
Such protection should be installed in adjacent to the controller. Connect to
the field if starter does not have "1" terminal on pilot devices and "6"
control fuses. terminal on starter.
B58
Engineering Data NEMA Controls - TM
Wiring Diagrams
Two-Speed, One Winding (Consequent Pole)
Wiring Diagram - Front View
For Starters 6058-TM, 6060-TM Combination
Elementary Diagram
Two Speed
One Winding
Motor
B
Connections For Case Mounted Transformer (When Provided) Wiring Diagram (Remove Wire "A")
Or Remote Pilot Devices
Momentary Contact Pushbuttons
B59
TM - NEMA Control Numbering System
Contactors & Non Combination Starters
Product Code
13 - Starters
30 - Rev. Starter Enclosure Type
31 - Rev. Contactors
A - NEMA 1
77 - Contactors
W - NEMA 4
90 - Part Winding Starters
R - NEMA 3R
T - NEMA 12
U - Open Type
T 13 A A 3 1 - 46
Number of Poles
1 - One Pole
2 - Two Pole
3 - Three Pole
4 - Four Pole
B60
Numbering System NEMA Control - TM
Combination Starters
T 18 T A 3 1 6 03 - T46
Disconnect
Enclosure Type Rating
Size of Starter
A - NEMA 1 2 - 240 Volts
W - NEMA 4 0 - Size 0
1 - Size 1 4 - 480 Volts
R - NEMA 3R 6 - 600 Volts
T - NEMA 12 2 - Size 2
3 - Size 3
4 - Size 4
5 - Size 5 Fuse Clip Size or Circuit Trip Rating or Range
6 - Size 6 Fuse Clip Size Motor Circuit Protector
(Applicable only to Bull. 6018-38 & 6318) (Used as standard at 440-600V)
03 - 30 amp 04 - 400 amp Adjustable Trip 600V AC Max.
06 - 60 amp 07 - 600 amp 71 - 3 amp 77 - 150 amp
Cover Control 01 - 100 amp 08 - 800 amp 72 - 7 amp 78 - 225 amp
A - Reset button in cover for 02 - 200 amp 10 - non-fused 73 - 15 amp 79 - 400 amp
overloads Class J Fuse Clip Size 74 - 30 amp 80 - 600 amp
B- Reset button and Hand-Off- 13 - 30 amp 12 - 200 amp 75 - 50 amp 81 - 800 amp
Auto selector switch 16 - 60 amp 14 - 400 amp 76 - 100 amp 82 - 1200 amp
C- Reset button and Start-Stop 11 - 100 amp 17 - 600 amp Thermal-Magnetic Trip Breaker
push button Class R Fuse Clip Size (Used as standard at 208-220V)
4 E- Hand-off Auto Selector Switch 93 - 30 amp 94 - 400 amp 00 - Non-Auto 10 - 200 amp
9
2 but no reset button 96 - 60 amp 97 - 600 amp 01 - 15 amp 11 -225 amp
F- Start-Stop push button but no 91 - 100 amp 98 - 800 amp 02 - 20 amp 12 - 250 amp
reset button 92 - 200 amp 03 - 40 amp 13 - 300 amp
O- None (no reset button or 04 - 50 amp 14 - 400 amp
Circuit Breaker Trip Rating or Range
controls in cover) 05 - 70 amp 15 - 500 amp
(Applicable only to Bull. 6020-40 & 6320)
06 - 100 amp 16 - 600 amp
07 - 125 amp 17 - 30 amp
08 - 150 amp 18 - 90 amp
09 - 175 amp 19 - 350 amp
B61
TM - NEMA Control Numbering System
2 Speed Starters
Cover Control
Type of Starter or Contactor A - Reset button in cover for overloads.
T - Standard unit with standard Type TM starter or contactor. B - Reset button and High-Off-Low selector switch.
Standard unit with vacuum starter or contactor. C - Reset button and Fast-Slow -Stop push button
V -
B U
A
-
-
Standard
Standard
unit
unit
with standard TM size 5 starter or contactor.
except with ambient compensated overload relays.
E
F
-
-
High-Off-Low selector switch but no reset button
Fast-Slow-Stop push button but no reset button
O - None (no reset button in cover)
Enclosure Type
A - NEMA 1 Size of Starter
S - NEMA 1 (Gasketed) 0 - Size 0 4 - Size 4
U - Open Type 1 - Size 1 5 - Size 5
W - NEMA 4 2 - Size 2 6 - Size 6
T - NEMA 12 3 - Size 3
Motor Windings
C - Consequent Pole
S - Separate Windings
T 60 A A 2 C 2 4 03 - 76
Product Code
50 - Non Combination 2 Speed
58 -Fused Combination 2 Speed
60 -C/B Combination 2 Speed
Number of Speed Disconnect
2 - Two Speed Rating
2 - 240 Volts
Motor Output 4 - 480 Volts
C - Constant Torque or HP 6 - 600 Volts
V - Variable Torque HP
Fuse Clip Size or Circuit Trip Rating or Range Suffix With Transformer
(secondary 110-120V with single fuse)
Fuse Clip Size Motor Circuit Protector Suffix
(Applicable only to Bull. 6058) (Used as standard at 440-600V) Transformer Primary 100 Watt
03 - 30 amp 04 - 400 amp Magnetic Adjustable Trip 600V AC Max. Volts & Hertz Standard Extra
06 - 60 amp 07 - 600 amp 71 - 3 amp 77 - 150 amp Capacity Capacity
01 - 100 amp 08 - 800 amp 72 - 7 amp 78 - 225 amp
220-240/60 or 220/50 - T26 - C26
02 - 200 amp 10 -non-fused 73 - 15 amp 79 - 400 amp
440-480/60 or 440/50 - T46 - C46
Class J Fuse Clip Size 12 - 200 amp 74 - 30 amp 80 - 600 amp
550-600/60 or 550/50 - T56 - C56
13 - 30 amp 14 - 400 amp 75 - 50 amp 81 - 800 amp
208/60 - T86 - C86
16 - 60 amp 17 - 600 amp 76 - 100 amp 82 - 1200 amp
380/50 - T35 - C35
11 - 100 amp Thermal-Magnetic Trip Breaker 220/25 - T22 - C22
Class R Fuse Clip Size 94 - 400 amp (Used as standard at 208-220V) 440/25 - T42 - C42
93 - 30 amp 97 - 600 amp 00 - Non-Automatic 10 - 200 amp
96 - 60 amp 98 - 800 amp 01 - 15 amp 11 -225 amp Suffix Without Transformer
91 - 100 amp 02 - 20 amp 12 - 250 amp
Coil Volts & Hertz Suffix 4
92 - 200 amp 03 - 40 amp 13 - 300 amp 110-120/60 or 110/50 - 76 9
14 - 400 amp 2
Circuit Breaker Trip Rating or Range 04 - 50amp 220-240/60 or 220/50 - 26
05 - 70 amp 15 - 500 amp 440-480/60 or 440/50 - 46
(Applicable only to Bull. 6060)
06 - 100 amp 16 - 600 amp 550-600/60 or 550/50 - 56
07 - 125 amp 17 - 30 amp 208/60 - 86
08 - 150 amp 18 - 90 amp
09 - 175 amp 19 - 350 amp
B62
Numbering System NEMA Control - TM
Reduced Voltage Auto Transformer Starters
Enclosure Type
Size of Starter
A - NEMA 1
U - 0 - Size 0 4 - Size 4
Open Type
W - 1 - Size 1 5 - Size 5
NEMA 4
T - 2 - Size 2 6 - Size 6
NEMA 12
3 - Size 3
T 82 A A 4 M E - 46
Product Code
82- Non Combination
83- Fused Combination
84- C.B. Combination
Line Voltage
A - 208V/60Hz E - 460V/60Hz
B - 230V/60Hz F - 440V/50Hz
C - 220V/50Hz G - 575V/60Hz
D - 380V/50Hz
Motor Horsepower
A - 5 HP M - 100 HP
B - 7 1/2 HP N - 125 HP
C - 10 HP P - 150 HP Suffix With Transformer Suffix Without Transformer
D - 15 HP Q - 200 HP (secondary 110-120V with single fuse) Coil Volts & Hertz Suffix
E- 20 HP R - 250 HP Suffix 110-120/60 or 110/ - 76
F- 25 HP S - 300 HP Transformer Primary 100 Watt 50 - 26
G - 30 HP T - 400 HP Volts & Hertz Standard Extra 220-240/60 or 220/ - 46
H - 40 HP U - 450 HP Capacity Capacity 50 - 56
J - 50 HP V - 500 HP 220-240/60 or 220/50 - T26 - C26 440-480/60 or 440/ - 86
K - 60 HP W - 600 HP 440-480/60 or 440/50 - T46 - C46 50
L - 75 HP X- Other 550-600/60 or 550/50 - T56 - C56 550-600/60 or 550/
208/60 - T86 - C86 50
380/50 - T35 - C35 208/60
220/25 - T22 - C22
440/25 - T42 - C42
B63
General Information 5000 - AC Control
Application
The 5000 Space Savers in NEMA Sizes 00 thru 5 offer versatile and compact AC contactors for industrial motor, heating and other
power circuit switching. Simplified design coupled with built-in reliability assures the user long, trouble-free operation in ma-
chine tools, process controls, air-conditioning, custom panels and other demanding applications.
B Description
All 5000 magnetically operated contactors incorporate a modern, modular design compatible with other control component
modules. Terminal location make them ideal for straight-through wiring and for wire-channel layouts. Accessible, up-front
pressure-type terminals are standard.
The hot molded, high arc resistant two or three piece housings not only totally enclose contacts and operating coils for environ-
mental protection; but also separate them as added protection against internal phase-to-phase short circuits.
Generous size, long wearing double break contacts are furnished on all sizes. Contacts are made of silver cadmium oxide for
"anti-weld" protection under high inrushes. Contacts do not require adjustment or periodic dressing (filing).
Coil Data
Standard coils for continuous duty service are equipped with pressure type terminals. Molded coil constrution resists moisture;
thermal and mechanical stress.
3. Three piece
molded housing.
8. Stainless
steel springs.
4. Arc b a r r i e r s . 1. Double Break silver
cadmium oxide contacts.
5. Side mounted
auxiliaries.
6. Free-floating arma-
ture-magnet frame.
7. Molded continuous
duty coil.
2. Pressure
3. Three piece type terminals.
molded housing.
B64
AC Control - 5000 Non-Reversing Contactors
1
Ratings - Ampere and Horsepower, Single Speed Motors
Amperes Three Phase - Horsepower Rating Single Phase - Horsepower Rating
Plug-Stop or Plug-Stop or
NEMA Starting Jogging Duty Starting Jogging Duty
Size Open Enclosed 115V 230V 480/575V 115V 230V 480/575V 115V 230V 115V 230V
3 1
00 10 9 /4 1 1
/2 2 ---- ---- ---- /3 1 1/2 ---- ----
1
0 20 18 2 3 5 1 1 1
/2 2 1 2 /2 1
1
1 30 27 3 7 /2 10 2 3 5 2 3 1 2
2 50 45 7 15 25 ---- 10 15 3 7 2 5
3 100 90 ---- 30 50 ---- 20 30 ---- ---- ---- ----
4 150 135 ---- 50 100 ---- 30 60 ---- ---- ---- ----
5 300 270 ---- 100 200 ---- 75 150 ---- ---- ---- ----
Notes:
1. These ratings are based on locked rotor current not exceeding six
times motor full load current for the max. horsepower rating.
B66
AC Control - 5000 Engineering Data
B67
Contactors & Starters Index NEMA Control
C1
HP - NEMA Control General Information
The Joslyn Clark NEMA Size Starter
That Saves You Money
3
8
0
C2
General Information NEMA Control - HP
Same energy efficient coil for NEMA Clear and easy to identify size,
sizes 00, 0, 1 & 2. Reduces trans- rating, and catalog number.
former size and cost. Small trans-
former size saves panel space. Low
VA inrush coil reduces line disturbance, AUXILIARY CONTACTS
ideal for use with solid state control.
Easy to install
4
8
5
C3
HP - NEMA Control AC Contactors
Note:
1. Price includes contactor complete with one N.O. 2. Price includes contactor complete with N.O. interlock on each 4
contol-circuit contact. contactor. All contactors are mechanically and electrically interlocked. 1
2
C
HP02AA3
HP10UO3 HPR10UO3
Note: 2. Price includes starter complete with N.O. interlock on each contactor and overload
0 relay less heaters. All starters are mechanically and electrically interlocked.
2
1. Price includes starter complete with N.O. interlock
3 and overload relay less heaters. 3. NEMA 3R add 60.00 to NEMA 12 List
C
HPS25AA3296
HPS25AA3296
Non-Fusible Disconnect Switch - Type HPS
NEMA Type 1 3
Maximum Motor Starter General Purpose NEMA Type 3R 3
1
Horsepower Rating Ampere Disconnect Enclosure Raintight
NEMA 2
Size 200V 230V 460/575V Rating Ampere Rating Catalog No. Price Catalog No. Price
00 1 1/2 1 1/2 2 9 30 HPS02AA3610 * $ 786. HPS02RA3610 * $ 1018.
0 3 3 5 18 30 HPS05AA3610 * 874. HPS05RA3610 * 1104.
1 7 1/2 7 1/2 10 27 30 HPS10AA3610 * 922. HPS10RA3610 * 1152.
2 10 10 25 45 60 HPS25AA3610 * 1378. HPS25RA3610 * 1678.
Control Circuit
Auxillary Contacts
Extra N.O. Contact 132. 132. KHP-M10 60.
Extra N.O. and N.C. Contacts All All 198. 198. KHP-M11 90.
Two extra N.O. Contacts 198. 198. KHP-M20 90.
6013 Same as type TM,
Enclosure Kits
& 6030 see Section B
Note:
1. Kits may be changed in the field from 3-position to 2-position operation. In addition to HAND-OFF-AUTO, four labels are included,
marked FORWARD-OFF-REVERSE: HIGH-OFF-LOW, TEST-LAG-LEAD, ON-OFF.
2. Lower Mounting Base for Fuse Clips- required only when converting a non-fusable unit to a fusable unit.
Modifications
Factory Installed Price Addition For Field Installtion
Kit Catalog Number Discount
For Type HP Add to Schedule
Bulletin NEMA Type Enclosure JC12
Description Number Size 1, 4 & 12 Type 1 Only Price
Control Transformer - Includes Single Fused 120 Volt Secondary
VA Primary
Capacity Voltage Hertz 2
3 208 KTR67-16
Standard
C Capacity
50
240 & 480
600 6013 &
324. KTR67-2
KTR67-12
$216.
50 00-2
Extra 3 208 60 6018 KTR67-20
Capacity 150 240 & 480 576. KTR67-5 $264.
600 KTR67-25
Miscellaneous
Ambient Compensated Overload Relay All 00-2 24.
Fused Control Circuit:
Fuse Holder for one fuse All 00-2 264. KHP-F1 $48.
Fuse Holder for two fuses KHP-F2 72.
NEMA Size
starters. Use type TM for these
applications.
C
02 - Size 00
05 - Size 0
10 - Size 1 Pilot Light
25 - Size 2
Number of Poles
2 - Two Pole L - Indicates a standard red pilot light.
3 - Three Pole P - Indicates a "Push-To-Test" red
transformer type pilot light with
nameplates.
No Letter - Pilot light not required.
Indicates Quantity of
Auxiliary Contacts
M10 = 1 N.O. Contact
M20 = 2 N. O. Contacts
M11 = 1 N.O. 1 N.C. Contact
Cover Control Indicates Type of
Bulletins 6013, 6018 & 7707 Overload Relay
A - Reset button in cover for A - Ambient compensated Suffix Without Transformer
overloads. No Letter - Non Ambient
Coil Volts & Hertz Suffix
B - Reset button and Hand-Off- compensated
Auto selector switch. 110-120/50 or 60 - 76
C - Reset button and Start-Stop 220-240/50 or 60 - 26
push button. 440-480/50 or 60 - 46
E - Selector switch no reset. 550-600/50 or 60 - 56
Disconnect Rating 200-208/50 or 60 - 86
F - Push button no reset.
O - None (no reset button in 2 - 240 Volts 277/50 or 60 - 66
cover) 4 - 480 Volts 24/50 or 60 - 96
6 - 600 Volts Suffix With Transformer
1 Bulletins 6030 & 6031
6
No number - No switch
A - Reset button in cover for (Secondary 110-120V)
6
overloads. Suffix
Transformer Primary
B - Reset button and Fwd.-Off- Volts & Hertz Standard 100 Watt
Rev. selector switch. Capacity Extra Capacity
C - Reset button and Fwd.- 220-240/50 or 60 - T26 - C26
Rev.-Stop push button. 440-480/50 or 60 - T46 - C46
O - None (no reset button in 550-600/50 or 60 - T56 - C56
cover) 200-208/50 or 60 - T86 - C86
C9
HP - NEMA Control Engineering Data
Type HP NEMA Sizes 00, 0, 1 & 2 Outline Drawings
31/2
7
3 /16 31/8
31/8
33/4
C
63/32
Provision for
#8/#10 screw (6)
31/8
51/8
33/8
2
221/32
5
/16 35/16
C10
Engineering Data NEMA Control - HP
Approximate Dimensions In Inches
Type HP NEMA Sizes 00, 0, 1 & 2 Outline Drawings
7
/8
D
B
C
5
/8 E C
A
1
8
6
C11
HP - NEMA Control Engineering Data
Wiring Diagram
Type HP - Non-Combination Starter
CONTROL FUSE
WHEN USED
WIRE "A"
"A"
Automatic Reset
Automatic reset operation should not
Connect To Coil Terminals be used with two wire control.
Separate Control
0
Remove wire "A" when it is supplied. 2
3
Connect separate control lines to the
"1" terminal on the pilot device and
the "4" terminal on the starter.
3 Position Selector Switch 2 Position Selector Switch
(Remove Lead from Coil (Remove Lead from Coil Two or More Momentary
to Term No. 3) to Term No. 3) Contact Pushbutton Stations
C12
Engineering Data NEMA Control - HP
Wiring Diagram
Type HPR - Non-Combination Starters
Automatic Reset
Automatic reset operation should
not be used with two wire control.
0 Separate Control
2
3 Remove wire "A" when it is
supplied. Connect separate control
lines to the "1" terminal on the pilot
device and the "8" terminal on the
starter.
C13
HP - NEMA Control Engineering Data
Wiring Diagram
Type HPF - Combination Starter
C Control fuses
when used
Primary fuses
when used
C14
Push Buttons 100T
Index
Description Page Number
100T Push Buttons: Page
General Information ..................................................................... D2
Push Buttons - Std. & Mushrooms .............................................. D4
Key Operated - Push Pull Push Buttons ..................................... D5
Illuminated Push Buttons ............................................................. D6
Illuminated Push Pull Units ........................................................... D7 C
Pilot Lights & Press-to-Test Pilot Lights ...................................... D8
Selector Switches: 2 - 3 - 4 Position .......................................... D9 D
Illuminated Selector Switches: 2 & 3 Position ............................. D11
Joy Sticks: 3 & 5 Position ............................................................ D12
Assembled Push Button Units ...................................................... D13
Assembled Stations: 1 - 2 - 3 Elements ..................................... D13
Assembled Selector Switch Units ................................................ D14
Separate Enclosures: 1 - 16 Hole .............................................. D15
Legend Plates ............................................................................. D16
Accessories ................................................................................. D17
Dimensions & Ratings ................................................................. D18
Catalog Numbering System ......................................................... D19
STAK-LITE NEMA Type 1, 3R, 12, 4X, and 13 ............................. D21
D1
100T General Information
Joslyn Clark Type 100T Heavy Duty Push
Buttons are available in Standard,
Mushroom Head, Push Pull, and Key-
Operated . Standard and Jumbo Mush- Joslyn Clark Type 100T Heavy Duty
room Head Selector Switches are available in
All units are suitable for use in NEMA Both mushroom heads fit the same opera- Standard Knob, Chrome Lever, Key-
Type 1, 3, 3R, 4, 4X, 12, and 13 tor and come in black, red, green, and Operated, Joy Stick and Selector-Push.
applications when mounted in enclo- yellow. The diameter of the standard
sures rated for those same applications. head is 1-3/8" - jumbo head is 2-1/4" in The standard knob and chrome lever
Although not needed on all Type 4X diameter. switches are obtainable with two, three
applications, protective caps provide and four position operators. They come
improved resistance to some corrosive in 2 position maintained and spring
materials. They are not required by UL.
Illuminated Push Button return; 3 position maintained, spring
Plastic Lens are available in seven return form right to center, left to center
D NEMA 13 Oiltight and NEMA 4 Water-
tight integrity is assured by a unique
colors and in standard and mushroom
head (13/8") variety. The operator
, right and left to center; and 4 position
maintained. Key operated switches
collapsing neoprene diaphragm. Three combines a momentary push button and come in two or three position main-
neoprene gaskets in back of the panel pilot light in one unit. tained and spring return and all 4
insure a tight fit and flexibility for position switches are maintained.
different thickness enclosures. The Push-Pull
diecast housing fits both standard Both Illuminated and Non-Illuminated There are several cams for all selector
oiltight mounting holes with a 1-13/64" standard mushroom heads are available switches in order to accomplish
or 30.56mm diameter. in 2 position maintained operators. numerous types of circuits. Positive
indexing assures operating reliability.
Single circuit double break contact Key-Operated
blocks are made of tough clear plastic When the key-type cylinder lock is Up to eight single circuit contact blocks -
for easy contact inspection. Blocks are depressed with or without key inserted - four on either side - may be attached to
attached to the operator by a single the operator is locked down and can any operator with a single captive screw
captive screw and positioning pin to only be released by the key. A red and positioning pin on each block.
make installation quick and easy. Up to jumbo mushroom head can be field or
8 blocks may be stacked on each push factory installed for emergency stop A tip on the locking thrust washer
button operator (2 wide, 4 deep). Up to applications. Other types of key extends through the legend plate to the
6 blocks on each selector switch. operations are obtainable. panel, locking both plate and operator in
position.
Brushed aluminum legend plates are
held in place by a locking thrust washer Legend plates are of brushed aluminum
which extends through the plate into the with etched black lettering. An octago-
panel for easy alignment. Standard nal aluminum guard ring locks operator
legend plates are 1-7/8" square with on the panel adding to the look of
black etched in letters. Jumbo automo- quality.
tive size 2-1/2" square legends are also
available. Standard Knob
Interchangeable knobs are of high-
Standard Operators impact plastic in black, red, green,
Interchangeable snap-on, reusable tough yellow and blue. They fit tightly to an
molded-in-plastic cups, are available in inner white knob which provides an
Black, red, green, yellow, amber, blue, white, easy-to-see white index mark for the
and brown. Your choice of three octagonal, cap.
brushed aluminum guard rings comes in:
Unguarded -Button extends beyond ring for Standard Knob Illuminated
easy access. Selector Switch
Guarded -Ring is flush with button to
Available with seven interchangeable
prevent accidental operation.
colored lenses in both two position
Extended-Ring extends beyond button
maintained and three position main-
Guard making accidental operation unlikely.
tained and spring return.
D2
General Information 100T
Selector Switches Pilot Lights Contact Blocks
(600 Volt)
Chrome Lever Features
These selector switches have the same Contacts enclosed in a clear plastic
operating characteristics as the Standard housing
Knob model. An extended chrome lever, Fine silver contact tips
1-3/4" long, provides quick and positive Long life steel springs
operation with or without gloves. Same contact block for all operators
"Quick-Stack" assembly
Key-Operated "Easy-Access" terminals
Key-operated switches have the same "One-Block-At-A-Time" removal
Joslyn Clark Type 100T Heavy Duty Pilot
positive action as the Standard Knob and Easy contact mode identification
Lights are available in Standard and
UL listed
Chrome Lever types. Operators are ob-
tainable with many key removal positions.
Press-To-Test. A choice of power con-
figurations to match various shock and
D
There are special keys available for added Joslyn Clark Type 100T Heavy Duty Con-
vibration levels insure longer lamp life.
security. tact Blocks are designed to simplify in-
Plastic lenses come in red, green, yellow,
stallation and assure trouble-free opera-
amber, blue, white and clear. All lamps
tion.
Joy Stick have bayonet type bases.
All 3 position and 5 position maintained Contacts are enclosed in sturdy plastic to
and spring return joy sticks have the same There are four basic power configura-
prevent foreign material from entering the
positive action as the other selector tions.
block. The clear plastic allows easy con-
switches. A special joy stick model can be tact inspection. Contact tips are made of
supplied with a release button on top. 1 Transformer Type (120, 240 or 480
fine silver for high conductivity. Strong
This prevents movement of the joy stick Volts) uses a modular heavy-duty
resilient springs reduce contact bounce
until the button is depressed - an excellent transformer - 50 or 60 Hertz - to step
and assure long reliable operation. The 3/
safety feature. line voltage down to 6 volts for longer
4" blocks may be used on all operators
lamp life under high shock and vibra-
installed side by side and four in tandem.
Selector-Push tion conditions.
Selector-Push operators combine the ac- The single No. 8 tapped-head captive
2 Resistor Type (120 or 240 Volts)
tions of a selector switch and momentary screw and positioning pin on each block
drops voltage to 60 and 120 volts
push button. A rotating collar provides the make stacking fast and easy. Terminals
respectively to lengthen lamp life in
selectivity needed to provide for several are inclined for direct access and speedy
less severe applications.
functions in one operator. wiring also angled to provide extra wiring
room. A self-rising saddle assures a solid
3 Full-Voltage Types (6, 12, 24 or 120
vibration resistant connection at each ter-
Volts) are used in applications with
minal for two No. 12 copper wires. Indi-
little shock or vibration. AC and DC
vidual block removal is automatic without
rated.
possibility of the entire stack coming off
when the top block is removed.
4 Neon Type (120 Volts) will withstand
extremely heavy shock and vibration
Contact mode is readily identified. Nor-
conditions - use of clear and yellow
mally-Open contact blocks have green
lens is recommended. AC and DC
operators marked with both N.O. and
rated.
symbol. The normally-closed
blocks have red operators and are marked
Standard with N.C. and symbol.
Dome Lenses are made of thick plastic,
fluted to give wide visibility. They come in
red, green, yellow, amber, blue, white and
clear.
Press-To-Test
Features and colors are the same as
Standard Pilot Lights except the lenses
are tubular. A N.O. and a N.C. contact
block comes with unit.
D3
100T Push Buttons
Pushbuttons Standard Contact Blocks
Momentary Operation
Rod Catalog
NEMA Type 1, 4, 12, 13 Type Symbol Color Number Price
Catalog 1-N.O. Green 100T-CB10 $18.00
Operator Color Number Price 100T-CB01 $18.00
1-N.C. Red
Black 100T-PB1B 100T-CBH012
Red 100T-PB1R 1-N.O. 1-Green
Green 100T-PB1G Standard 100T-CB111 $36.00
Extended & 1-N.C. & 1-Red
Pushbutton Yellow 100T-PB1Y $32.00 Contact Block
Extended Amber 100T-PB1A 1. Consists of one 100T-CB10 and one 100T-CB01 packaged together.
Blue 100T-PB1E 2. Additional spring pressure for resistance to vibration.
White 100T-PB1W
Brown 100T-PB1N Contact Ratings
None 100T-PB1O $32.00 NEMA Amps. VA.
Black 100T-PB2B Rating Max.
D Red
Green
100T-PB2R
100T-PB2G
Desig. Volts Make Break Continuous Make Break
Maximum A-C Contact Rating Per Pole, 50 or 60 Hertz.
Yellow 100T-PB2Y $32.00
Flush 120 60 6
Flush Amber 100T-PB2A
Pushbutton A600 240 30 3 10 7200 720
Blue 100T-PB2E
White 100T-PB2W 480 15 1.5
Brown 100T-PB2N 600 12 1.2
None 100T-PB2O $32.00 Maximum D-C Contact Rating Per Pole
Black 100T-PB4B 125 1.1
1-3/8 inch Red 100T-PB4R $68.00 P600 250 0.55 5 138
Mushroom Green 100T-PB4G 301-600 0.2 120
Yellow 100T-PB4Y
1-3/8 inch None 100T-PB4O $60.00 Pushbutton Color Caps and Mushroom Head
Mushroom Head Black 100T-PB5B Color Caps for 1-3/8 inch 2-1/4 inch
2-1/4 inch
Mushroom Red 100T-PB5R $68.00 Flush Mushroom Head Mushroom Head
Green 100T-PB5G Unguarded or for Mushroom for Mushroom
Yellow 100T-PB5Y Guarded Push Buttons and Buttons and
Buttons Push Pull Units Push Pull
Selection Guide Units
Select push button operators from table above and contact blocks from table
on the right. Select legend plates from page D16. Catalog Catalog Catalog
Color Number Price Number Price Number Price
For complete units see pageD13. All units on this page will accept a total of Black 100T-BB 100T-BM4B 100T-BM5B
eight contact blocks. Red 100T-BR 100T-BM4R $8.00 100T-BM5R $8.00
Green 100T-BG 100T-BM4G 100T-BM5G
Yellow 100T-BY 100T-BM4Y 100T-BM5Y
Amber 100T-BA $1.00
Blue 100T-BE
Item Page Item Page White 100T-BW
Accessories D17 Pilot Lights D7 Brown 100T-BN
Legend Plates D16 Selector Switches D8 Mixed 100T-BM $8.00 100T-BM4M $32.00
Ratings and Dimensions D18 Special Devices D4
Assembled Units D13 Assembled Stations D13
Ordering Information
Complete Control Unit Consists Of:
OFF
Complete
+ + = Push Button
Unit
Push-Pull Units
Description 1
Unit Locks in
Catalog No. Price
Comes with 13/8 inch Standard Mushroom Head. D
Depressed Legend Plate and Contact Blocks not included.
Position Key 100T-PB61 $104.00
Description Color 4 Catalog Number Price
Required to Legend Plate &
Release Contact Blocks Black 100T-PP4B $104.00
Chrome Unit Not Included Maintained Red 100T-PP4R 104.00
None 100T-PP40 96.00
1. 100T-BM6R 2 1/4 inch Red Mushroom Head available for
1. For colors not listed, or for units with 2 1/4 inch diameter Mushroom
this unit at $36.00 List Price each.
Heads, order with "none" and select desired Mushroom Head from
below.
Complete
+ + = Push Button
Unit
Ordering Information
Complete Control Unit Consists Of:
MOTOR
STOP
Complete
+ + = Push Button
Unit
Ordering Information
Complete Control Unit Consists Of:
Complete
+ + = Push Button
Unit
5 Packaged 1 per carton except 100T-LM contains seven lenses one of each color.
6 Packaged 1 per carton except 100T-LBM contains seven lenses one of each color
($58.80/ ctn).
7 Packaged 1 per carton except 100T-LBMM contains seven lenses one of each color
$58.80/ctn).
1 Available in other colors Change "B" in operator catalog number to "R" for Red, "G" for Green, "Y" for Yellow,
Key Operated or "E" for Blue.
2 Available without Knob Change "B" in operator Catalog number to "O" and select knob from table below.
100T-SK3M
3 Cam code is a part of catalog number: Example 100T-SS3MB3 See table of cam developments.
4 Key Removal code is part of catalog number. Example: 100T-SK3B3C See Key Removal table below.
Key Spare Parts Color Plastic Knobs
- For Standard Key Operator use 100T-3095 @ $17.00 using JC80 disc. sch.
- For 501 Key Operator use 100T-CH501 @ $28.00 using JC80 disc. sch. Standard Plastic
Knob for Knob
Key Removal Codes Operated Selector
Two Position Three Position Four Position Switches
Maintained Spring Return Left Right Catalog
Key Left Right Center Right Left Center Right Left Center Center Right Color Number Price 5
Removal Black 100T-SB $8.00
Code Red 100T-SR 8.00
L (Left) Yes No ----- ----- Yes No No Yes No No No Green 100T-SG 8.00
R (Right) No Yes No Yes No No Yes No No No Yes Yellow 100T-SY 8.00
C (Center) ----- ----- Yes No No Yes No ----- ----- ----- ----- Blue 100T-SE 8.00
A (All) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Mixed 100T-SM 40.00
NOTE: No 501 Key is available for above Key Operators Selector Switches. To order add "5" for 5 Packaged one per carton except
501 Key to the end of the catalog number add $24.00 to list price. 100T-SM contains one of each
Example: 100T-SK2M1A5. color knob.
Ordering Information
Complete Control Unit Consists Of:
Complete
+ + = Push Button
Unit
Ordering Information
Complete Control Unit Consists Of:
F O
F N
O Complete
+ + = Push Button
Unit
D 5 Position
Maintained 100T-JS5M 212.00 100T-JP5M $260.00
100T-JP5M Joy Stick Unit 5 Position
Spring Return 100T-JS5B 212.00 100T-JP5B $260.00
to Center
Three Position Joy Stick - Contact Sequence Five Position Joy Stick - Contact Sequence
Contacts 1 Contacts 4 Joy Stick Position
Joy Stick Position (Front View)
Location Type (Front View) Location Type
(Front and Rod (Front and Rod Left Up Center Down Right
Type View) Symbol Color Left Center Right Type View) Symbol Color c
N.O. N.O.
Three Position, Left Green X O O Five Position, Green O O O X O
Left
Maintained and N.C. Maintained and N.C.
Spring Return Red O O X Spring Return Red O X O O O
to Center, With N.O. to Center, With N.O.
or Without Green O O X or Without Green O O O O X
Right Right
Release Button N.C. Release Button N.C.
Red X O O Red X O O O O
1. Contact Blocks are not supplied. Order contact blocks from table 4. Contact Blocks are not supplied. Order contact blocks from table
below. below.
Ordering Information
Complete Control Unit Consists Of:
Complete
+ + = Joy Stick
Unit
1-N.C.
Black
Red
100T-PB1B-10X
100T-PB1R-01X
$50.00
$50.00
STOP (red 21/4" mush-
room push button) 100T-S1-5 192. 100T-W1-5 324.
D
OFF-ON (black knob
1-N.C. Black 100T-PB1B-11X $68.00 selector switch) 100T-S1-6 168. 100T-W1-6 300.
HAND-OFF-AUTO (black
1-N.O. Red 100T-PB1R-11X $68.00
knob selector switch) 100T-S1-7 168. 100T-W1-7 300.
1-N.O. Black 100T-PB2B-10X $50.00 FWD-OFF-REV (black
knob selector switch) 100T-S1-8 168. 100T-W1-8 300.
1-N.C. Black 100T-PB2B-11X $68.00 Two Element Stations
Guarded START-STOP (black
Red 100T-PB2R-11X $68.00 guarded-red unguarded
1-N.O. Green 100T-PB2G-11X $68.00 push buttons) 100T-S2-1 240. 100T-W2-1 372.
START-STOP (black
1 3/8" 1-N.C. Black 100T-PB4B-11X $104.00 guarded-red 13/8" mush-
Mushroom room push buttons) 100T-S2-2 276. 100T-W2-2 408.
1-N.O. Red 100T-PB4R-11X $104.00 FORWARD-REVERSE
(black guarded-black
2 1/4" 1-N.C. Black 100T-PB5B-11X $104.00
guarded push buttons) 100T-S2-3 240. 100T-W2-3 372.
Mushroom OPEN-CLOSE (black
1N.O. Red 100T-PB5R-11X $104.00
guarded-black guarded
Illuminated 1-N.C. push buttons) 100T-S2-4 240. 100T-W2-4 372.
Push Button UP-DOWN (black guarded
120V Trans- Red 100T-PBLT1R-11X $164.00 -black guarded push
former Type 1-N.O. buttons) 100T-S2-5 240. 100T-W2-5 372.
Three Element Stations
Illumated 1-N.C. FORWARD-REVERSE-
Push Button STOP (black guarded-
120V Re- Red 100T-PBLR1R-11X $140.00 black guarded-red
sistor Type unguarded push buttons) 100T-S3-1 324. 100T-W3-1 528.
1-N.O.
OPEN-CLOSE-STOP
(black guarded-black
guarded-red unguarded
push buttons) 100T-S3-2 324. 100T-W3-2 528.
UP-DOWN-STOP (black
guarded-black guarded-red
unguarded push buttons) 100T-S3-3 324. 100T-W3-3 528.
START-STOP-JOG (black
guarded-red unguarded-
black guarded push
buttons) 100T-S3-4 324. 100T-W3-4 528.
START-STOP-MOTOR
RUN (black guarded-red
Assembled 100T Push Button Stations unguarded push buttons-
red 120 volt transformer
The most commonly used push button stations are available assembled in unguarded pilot light) 100T-S3-5 384. 100T-W3-5 588.
NEMA Type 13 (oiltight and dustight) sheet steel and in NEMA 4 (water-
tight) stainless steel enclosures. 1 Use NEMA 13 enclosures for applications requiring NEMA1.
2 Protective watertight boots are not required for indoor (non-freezing)
For custom control stations not listed, order operators, contact blocks, applications. If for outdoor (freezing) use, order boots as separate items,
from page D17.
nameplates, and enclosures as separate items.
D
2 Position Selector Switch (Does not include Legend Plate)
Contacts Selector Position Complete Catalog No. and Price for Assembled Unit
Location Type (Front View) Black Knob Operator Chrome Lever Operator
(Front and Rod Left Center Right Catalog Catalog
Type View) Symbol Color No. Price No. Price
N.O.
2 Position Green O -- X 100T- 100T-
Maintained Left
N.C.
Red X -- O SS2MB1-11X $80.00 SL2MC1-11X $80.00
2 Position N.O.
Spring Re- Green -- O X 100T- 100T-
Left
turn Right to N.C.
Center Red -- X O SS2RB1-11X 104.00 SL2RC1-11X 104.00
N.O.
Green O O X O
Left
N.C.
4 Position Red X O O O 100T- 100T-
Maintained
N.O.
Green O X O O SS4MB8-22X $116.00 SL4MC8-22X $116.00
Right
N.C. Red O O O X
Only on
NEMA 4 1. Use NEMA 13 enclosures for applications requiring NEMA 1.
2. Protective watertight boots are not required for indoor (non-
freezing) applications.
If for outdoor (freezing) use, order boots as separate items
3
313/64 /4 14 NPT For from page D17.
+
1,2,&3 Unit Stat.
11/2
1-111/2 NPT
For 4,5,&6 Stat.
Ordering Information
Select enclosure desired by catalog number. Select Pilot Devices from 100T section.
Non-Standard Legend Plates - Can be provided with special markings at $15.60 list
each.
MOTOR O
STOP
FF N
O
D
Catalog No. Catalog No. Catalog No. Catalog No.
Standard Size Jumbo Size Standard Size Jumbo Size
Marking 1-7/8" Square 1 2-1/2" Square 2 Marking 1-7/8" Square 1 2-1/2" Square 2
For Push Buttons and Pilot Devices For Two Position Selector Switches
Start 100T-L01 100HF-N701 Man-Auto 100T-L51 100HF-N751
Stop 100T-L02 100HF-N702 Off-On 100T-L52 100HF-N752
Fast 100T-L03 100HF-N703 For-Rev 100T-L53 100HF-N753
Slow 100T-L04 100HF-N704 Safe-Run 100T-L54 100HF-N754
Open 100T-L05 100HF-N705 Jog-Run 100T-L55 100HF-N755
Close 100T-L06 100HF-N706 High-Low 100T-L56 100HF-N756
Off 100T-L07 100HF-N707 Open-Close 100T-L57 100HF-N757
On 100T-L08 100HF-N708 Up-Down 100T-L58 100HF-N758
Up 100T-L09 100HF-N709 Hand-Auto 100T-L59 100HF-N759
Down 100T-L10 100HF-N710 Start-Stop 100T-L60 100HF-N760
Raise 100T-L11 100HF-N711 Run-Jog 100T-L61 100HF-N761
Lower 100T-L12 100HF-N712 Start-Jog 100T-L62 100HF-N762
Low 100T-L13 100HF-N713 For Three Position Selector Switch
High 100T-L14 100HF-N714 Hand-Off-Auto 100T-L71 100HF-N771
Out 100T-L15 100HF-N715 Auto-Off-Hand 100T-L72 100HF-N772
In 100T-L16 100HF-N716 For-Off-Rev 100T-L73 100HF-N773
Jog 100T-L17 100HF-N717 Open-Off-Close 100T-L74 100HF-N774
Inch 100T-L18 100HF-N718 Man-Off-Close 100T-L75 100HF-N775
Reset 100T-L19 100HF-N719 For-Safe-Rev 100T-L76 100HF-N776
Run 100T-L20 100HF-N720 Run-Safe-Jog 100T-L77 100HF-N777
Forward 100T-L21 100HF-N721 Jog-Safe-Run 100T-L78 100HF-N778
Reverse 100T-L22 100HF-N722 Up-Off-Down 100T-L79 100HF-N779
Jog Forward 100T-L23 100HF-N723 For Four Position Selector Switches
Jog Reverse 100T-L24 100HF-N724 1-2-3-4 100T-L31 100HF-N731
Emergency Stop 100T-L25 100HF-N725
For Joy Stick Operator
Push Stop 100T-L41 100HF-N741
Pull Start (Blank) 100T-L30 100HF-N730
Cycle Start 100T-L83 100HF-N783 1 Character height is 1/8 inch on Standard Legend Plate.
Cycle Stop 100T-L84 100HF-N784 2 Character height is 1/4 inch on Jumbo Legend Plate.
Notes:
1. Use the trim washer if no legend plate is used. Discard the trim
washer when using a legend plate.
2. Must be 1-5/8" for 100-HF Legend Plate
3. Must be 1-1/8" for 2-1/4" Mushroom Head
Contact Power Contact
4. When using 100-HF Legend Plate, both horizontal and vertical
centerlines between operators must be 2-1/2" min. Block Supply Block
When using either 2-1/4" mushroom head or lever selector
switch, both horizontal and vertical centerlines between opera-
tors must be 2-1/4" min.
5. Depth when three neoprene spacers are used. Reduce depth
by 1/16 inch for each spacer omitted.
6. Depth per contact block. Maximum contact stack depth is three
(3) inches.
100T - PB1 B - 10 X
Operator Type Color Cap Contacts
PB1 - Unguarded - Push Button *B- Black See Contact Block Chart
PB2 - Guarded - Push Button *R- Red on Page D20
PB4 - Std. Mushroom Head - Push Button *G- Green
PB5 - Jumbo Mushroom Head - Push Button *Y- Yellow
PB61 - Key Operated Push Button A-
E-
Amber (Orange)
Blue
D
PP4 - Push-Pull 2 Position Mushroom Head
N- Brown
W- White
C- Clear
O- No Cap
* Colors Available For
Mushroom Heads
Selector Switch
Operator Type Position Operator Function
SS - Selector Switch Knob (standard) 2 - 2 Position Selector Switch M- Maintained
SL - Selector Switch Lever 3 - 3 position Selector Switch R- Spring Return from Right
SK - Selector Switch Key 4 - 4 Position Selector Switch L- Spring Return from Left
JS - Joy Stick B- Spring Return from Both
JP - Joy Stick w/Release Button Left and Right
100T - SS 2 M B 1 - C - 11 X
Bulletin Number Assembled
Cam Number Key Removal Position
Color Insert See Tables on Cat. Key Selector Switch Only Contacts
B - Black E - Blue on Page 10 L - Left Only See Contact Block Chart
R - Red C - Chrome Lever R - Right Only on Page D20
G - Green O - No Cap C - Center Only
Y - Yellow A - All Positions
100T - PL R 2 A
Operator Type Power Supply Voltage Lens Color
PL - Std. Pilot Light T- Transformer Type 1 - 120 6- 6 R -Red E - Blue
PT - Press-to-Test Pilot Light R- Resistor Type 2 - 240 7 - 12 G -Green W - White
F- Full Voltage Type 4- 480 8 - 24 Y - Yellow C - Clear
N- Neon Type A - Amber O - No Lens
100T - PBL T 1 R 11 X
D
Voltage Lens Color Contacts
1 - 120 6- 6 R- Red E- Blue See Contact Block Table
2 - 240 7 - 12 G- Green W- White Below
4- 480 8 - 24 Y- Yellow C- Clear
A- Amber O- No Lens
100T - S1 3 M T 1 R 3 - 10 X
Operator Function Voltage Lens Color Cam Function
M- Maintained 1 - 120 6- 6 R- Red E - Blue See Cam Numbers on
R- Spring Return From Right 2 - 240 7 - 12 G- Green W - White Page 10
L- Spring Return From Left 4- 480 8 - 24 Y- Yellow C - Clear
B- Spring Return From Both A- Amber O - No Lens
(Left and Right)
Joslyn Clark's STAK-LITE® will tell you what is happening. From far or near, the bright LITE-BARTM
status lights instantly communicate the information you need.
Joslyn Clark's STAK-LITE® is a versatile and high quality monitoring component for the VISUAL
FACTORY. The units are designed to NEMA 1, 3R, 12, 4X, and 13 standards which make them
ideally suited for harsh environments commonly found on the factory floor.
Joslyn Clark's STAK-LITE® status indicators come in six colors: Red, Green, Amber, Blue,Frosted
White, and clear, and are available for either steady or flashing operation.
Available in 9 MM or 15 MM
Filament Bulbs
D
Led Lamps available in 6 Colors
D22
D21
100T Notes
Stak-Lite Technical Data
Codes, standards and approvals: All Stak-Lites are UL listed and CSA
certified. As supplied, assembled Stak-Lites are rated as Type 1, 12, or 13 enclo-
sures and may be conduit or panel mounted.
Environments: To convert to Type 3R, knock out one of the two bolt holes in the
mounting base. Stak-Lites modified for Type 3R cannot be panel mounted as panel
mounting would interfere with drainage.
Audible output / frequency: 95dB sound pressure level at 1.0 foot @ 2800Hz.
tone frequency 30.5 Hz.
Electrical Wiring: All wiring is copper. Wiring and insulation is rated at 300V,
105 Deg. C.
In leads out version, wire destination is determined by length. The shortest black wire
coming out from the base goes to the bottom lens; the longest black wire goes to the
bottom lens. Leads out Stak-Lites with the flasher option have only one white wire
common to all positions.
Table 1
Height
Number of
Lenses 0 1 2 3 4 5 6
With
Leads "out" ---- 5" 8" 11" 14" 17" 20"
With terminal
block "or" leads 5" 8" 11" 14" 17" 20" 23"
out with base
options
Maximum height is 23" from bottom of mounting base to top of cap.
Terminal referencing: Optional terminal boards feature two vertical sets of connectors
numbered 1-6 and one horizontal set of connectors numbered 1-6 and "N". These numbers
correspond with lens position, with 1 being the top lens, 2 the next lens down, and so on.
The set of vertical connectors on the left is for black (hot) leads; the set on the right is for
white (neutral) leads. The horizontal set is for customer connections.
D22
STAK-LITE ® Status Indicator
Status Indicating System - Asembled
Total SL System SL System SL System W/Audible SL System W/Audible
Number With 18" Wire Leads With Terminals Signal and 18" Wire Leads Signal & Terminals
Lamps Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
1 SL1-*1 $150. SLT1-*1
$230. SLA1-* 1
$290. SLTA1-* 1
$370.
2 SL2-*1 236. SLT2-*1 316. SLA2-*1 376. SLTA2-*1 456.
3 SL3-*1 322. SLT3-*1 402. SLA3-*1 462. SLTA3-*1 542.
4 SL4-*1 408. SLT4-*1 488. SLA4-*1 548. SLTA4-*1 628.
5 SL5-*1 494. SLT5-*1 574. SLA5-*1 634. SLTA5-*1 714.
6 SL6-*1 580. SLT6-*1 660. SLA6-*1 720. SLTA6-*1 800.
NEMA 4X For NEMA 4X add 4 in front of the catalog number and multiply list price time 1.5. NEMA 4X
not available with audible alarm. D
Flasher Installed: Add $100.00 total for each set of 3 lights, add letter F after color light that should flash.
Example: SL4-120-RFGFACF
Strobe Installed: Add $300.00 per light and add letter S after light that is to be a strobe.
Example: SL5-120-CSRGBA Note: Strobe flashes 75 times/minute.
When ordering, specify light colors in sequence from top to bottom on the STAK-LITE®
Strobe and Flasher can be added to the same unit in any sequence.
Top Cap: Standard color is black,
Cap to match top color, add suffix "V" after designated color.
Example: SL3-120-RVAG (Add $40.00 to list)
Chrome Cap, Add suffix "CR" to the end of the catalog number.
Example: SL3-120-RAG-CR (Add $40.00 to list)
Special Lamp: If 15mm lamp is required, put a "B" after voltage; example:(SL1-120B-R).
Special Lamp: If Led lamp is required, put an "L" after voltage; example:(SL1-120L-R). (Consult Factory for Pricing)
Modular System And Accessories
Description Catalog No. Price
Flasher Assemblly (3 Lts. Max. per Flasher) KSLF- * $ 100.00
Strobe Light (120V, 240V only) KSLS- * 1 300.00
Gasket for Base and Lens (Qty. 2) KSLG 6.00
Chrome Retaining Cap KSLC 40.00
Retaining Cap to match Lens Color KSLC- 1 50.00
Lens Assembly KSLL09- 1 75.00
Lens Only (Does not include post or lamp holder) KS-1 40.00
Mounting Base KSLB 40.00
Terminal Board Assembly KSLT 80.00
Audible Alarm Assembly (97 DB’s at 1 foot) KSLA- * 140.00
Lamp Holder only for 9mm KSL-09 34.00
Lamp Holder only for 15mm KSL-15 34.00
- For mounting flange and extending tubing, see accessories page D26
- For wire leads 36" or 48" there is a $20.00 adder
1
Ordering Information * A.C. Voltage Color
* Select Lamp Voltage From Chart 6 VAC -6 Red - R
1
Select One Color For Each Lens From Chart 12 VAC -12 Amber - A
Example: 24VAC -24 Green - G
SL4-120 RAGC is 4 Lamp 120 VAC 48VAC -48 Clear - C
STAK-LITE® Assembled With 120VAC -120 Blue - B
Red, Amber, Green and Clear Lens 240VAC -240 White - W
Black - K
D23
Status Indicator STAK-LITE ®
STAK-LITE Mounted On Switch Panel 1
1. NEMA 1 Enclosure complete with one switch for every light and 9 ft. - 120 VAC fused line cord. All units include
(3) Position Switch. Up-Steady, Center-Off, Down-Flashing.
EXAMPLE: (4) Lights - Red, Amber, Green, and Blue, with 8" Extended Tubing.
SLE4-08-RAGB $792.00 List.
Audible Alarm: Add (A) after 3rd. digit of catalog number, and add $140.00 List.
Example: SLEA3-04-R,A,G $826.00 List.
Strobe : Add Letter (S) after the letter for the color that is to be a strobe and add 300.00 List.
Example: SLE4-08-RS,A,G,B $1092.00 List.
Colored Top Cap: For top cap made from colored lens material add letter (V) after light color that matches
lens color and add $50.00 List.
Example: SLE4-08-RV,A,G,B $842.00 List.
Separate Lamps
Separate Lenses (AC or DC) 9MM
Color Catalog No. Price Voltage Catalog No. Price
Red KS-R $40. 6 VAC KRB09-6 $13.00
Amber KS-A 40. 12 VAC KRB09-12 13.00
Green KS-G 40. 24 VAC KRB09-24 13.00
Clear KS-C 40. 48 VAC KRB09-48 13.00
Blue KS-B 40. 120 VAC KRB09-120 13.00
White KS-W 40. 240 VAC KRB09-240 13.00
• One Lamp required for every height of
• One Lens required for every height of frame. frame.
Separate Lamps
(AC or DC) 15MM
Voltage Catalog No. Price
6 VAC KRB15-6 $20.00
STAK-LITE Options 12 VAC KRB15-12 20.00
24 VAC KRB15-24 20.00
Description Catalog No. Price 48 VAC KRB15-48 20.00
120 VAC KRB15-120 20.00
3/4" Conduit Mounting Flange 1 KSLH $30. 240 VAC KRB15-240 20.00
Extended Tubing - 4" KSLP04 24.
Extended Tubing - 8" KSLP08 34. • One Lamp required for every height of
frame.
Extended Tubing - 16" KSLP16 44.
1 The standard unit can be panel mounted directly to any flat surface
through two 5/16" DIA. holes. To elevate the unit, use standard 3/4"
conduit or JCC Extended Tubing, and the KSLH mounting flange.
Separate LED Lamps
E1
AC Starters Pump Controllers
As standard all 3 phase controllers include transformer and H-O-A selector switch for each starter.
Duplex Controller with Single Disconnect Duplex Controller with Two Disconnect
Switch & Two sets of Fuse Blocks Switches & Two sets of Fuse Blocks
E NEMA Starters NEMA Starters
Maximum Fuse Maximum Fuse
NEMA Horsepower Clips NEMA Type 2 NEMA Horsepower Clips NEMA Type 2
Cont. Rating Amp Enclosure Cont. Rating Amp Enclosure
Size 200V 230V Rating Catalog No. Price Size 200V 230V Rating Catalog No. Price
0 3 3 30 DSNE00BE3203- * $2420. 0 3 3 30 DDNE00BE3203- * $2760.
C 1
1
5
71/2
71/2
71/2
30
60
DSNE10BE3203-
DSNE10BE3203-
* 2520.
2700.
1
1
5
71/2
71/2
71/2
30
60
DDNE10BE3203-
DDNE10BE3206-
* 2820.
3200.
* *
2 10 15 60 DSNE20BE3203- * 2880. 2 10 15 60 DDNE20BE3206- * 3360.
3 25 30 100 DSNE30BE3203- * 6560. 3 25 30 100 DDNE30BE3201- * 7720.
4 40 50 200 DDNE40BE3202- * 10300.
460-575V 460-575V
E 0
1
5
10
30
30
DSNE00BE3603-
DSNE10BE3603-
*
*
$2480.
2580.
0
1
5
10
30
30
DDNE00BE3603-
DDNE10BE3603-
*
*
$2820.
2880.
2 15 30 DSNE20BE3603- * 2760. 2 15 30 DDNE20BE3603- * 3260.
2 25 60 DSNE20BE3606- * 2920. 2 25 60 DDNE20BE3606- * 2920.
3 50 100 DSNE30BE3601- * 6560. 3 50 100 DDNE30BE3601- * 7720.
4 100 200 DDNE40BE3602- * 10300.
Triplex Controller with Single Disconnect Triplex Controller with Three Disconnect
Switch & Three sets of Fuse Blocks Switches & Three sets of Fuse Blocks
460-575V 460-575V
0 5 30 TSNE00BE3603- * $3100. 0 5 30 TTNE00BE3603- * $3700.
1 10 30 TSNE10BE3603- * 3860. 1 10 30 TTNE10BE3603- * 4460.
2 15 30 TSNE20BE3603- * 3980. 2 15 30 TTNE20BE3603- * 4780.
2 25 60 TSNE20BE3606- * 4140. 2 25 60 TTNE20BE3606- * 4940.
Note: For circuit breaker in place of switch, add $84.00 list per switch.
For circuit breaker in place of power fuse block, add $160.00 list per block. 3
8
0
Ordering Information Coil Table
Select Catalog Number and Price for largest Motor HP size. If different HP sizes are required Specify Voltage/Hertz Suffix
with modification "S" from page E3. 220-240/60 or 220/50 - T26
Pump Controllers include heaters for NEMA Starters 440-480/60 or 440/50 - T46
When ordering specify each motor full load amps, HP and Voltage for correct selection of motor 550-600/60 or 550/50 - T56
overload protection. 200-208/60 - T86
Use complete catalog number. Replace the (*) with the suffix from coil table.
Modifications
CF = Consult Factory * Specify Contactor size for a Duplex Pump (ie: S220=pump 1 NEMA size 1)
E3
Numbering System Pump Controllers
Duplex & Triplex Pump Control Catalog Numbering
DS = Duplex Single Switch 2 Fuse Blocks A = Alternating Relay J = Timer For Delayed Alarm
DD = Duplex Double Switch 2 Fuse Blocks A1 = Triplex Alternating Relay Activation - Specify Alarm
DO = Duplex No Switch or Fuse Block Pumps 1 & 2 Only To Be Delayed
(Non-Combination) A2 = Triplex Alternating Relay K = Surge Arrestor
TS = Triplex Single Switch 3 Fuse Blocks Pumps 2 & 3 Only L1 = Light - Power On
TD = Triplex Double Switch 3 Fuse Blocks A3 = 24 Hour Alternating Relay L2 = Light - Pump Run For Each
TT = Triplex Three Switch 3 Fuse Blocks A4 = Manual Alternation Selector Pump
SS = Simplex Switch & Fuse Block Switch L3 = Light High Water Level
B = Min. Run Timer All Pumps L4 = Light Low Water Level
B1 = Min. Run Timer Pump 1 L5 = Light - Specify Function
B2 = Min. Run Timer Pump 2 M = N.O. Pump Run Contacts
B3 = Min. Run Timer Pump 3 P1 = Power Fuses
C = Time Delay Start In Auto R1 = 4 Pole Relay - Specify
All Pumps Function
C1 = Time Delay Start In Auto S1* = Alternate Starter Size For
NE = NEMA Starters - HP Sizes 0-2 Pump 1 Pump 1
TM Size 3 & 4 C2 = Time Delay Start In Auto S2* = Alternate Starter Size For
E C3
Pump 2
= Time Delay Start In Auto
Pump 2
S3* = Alternate Starter Size For
Pump 3 Pump 3
D = Off Delay Timer All Pumps Pressure Switches
D1 = Off Delay Timer Pump 1 Mounted
B = Type 2 Enclosure D2 = Off Delay Timer Pump 2 On Outside Of Enclosure
R = Type 3R Enclosure D3 = Off Delay Timer Pump 3 T1 = 5-150 PSI, Bourdon Type
D = Type 3R Double Door Enc. E = Elapsed Time Meter for T2 = 10-200 PSI, Bourdon Type
T = Type 12 enclosure each Pump Running T3 = 10-300 PSI, Bourdon Type
W = Type 4 Stainless Steel F1 = Mounting Feet 12" T4 = 18-116 PSI Diaphragm Type
P = Type 4 Painted Steel H1 = Audible & Visible Alarm With T5 = 15-232 PSI Diaphragm Type
S = Type 4 Painted Steel Silencing Circuit - Signal T6 = 2-60 PSI, For Low Suction
With Double Door Source Separate Alarm
DS NE 20 R E 3 6 03 -T46 A D - 20/460
Contactor Sizes * 3 = 3 Phase Transformer and Voltage
05 = HP05 Starter 2 = Single Phase Code Suffix refer to
10 = HP10 Starter Page C9.
25 = HP25 Starter
30 = TM3 Starter 1 = 120 Volt Rating Horse Power / Voltage
40 = TM4 Starter 2 = 250 Volt Rating
6 = 600 Volt Rating
Fuse Clip Size Fuse Clip Size
Cover Controls
Fuse Clip Class R Fuse Clip
O = Internal O/L Reset Only 03 - 30 ampere 93 - 30 ampere
E = H-O-A Internal O/L Reset 06 - 60 ampere 96 - 60 ampere
B = H-O-A with External O/L Reset Class J Fuse Clip No number or
F = Start-Stop PB'S Internal O/L Reset 13 - 30 ampere 00 - no clips
1
6
C = Start-Stop PB'S W/External O/L Reset 16 - 60 ampere
6
Ordering Information
As standard all 3 phase controllers include transformer and H-O-A selector switch for each starter.
Select Catalog Number and Price for largest Motor HP size. If different HP sizes are required specify
with modification "S" to change starter size.
Pump Controllers include heaters for NEMA Starters
When ordering specify each motor full load amps, HP and Voltage for correct selection of motor overload protection.
Complete Cat. No. by including HP & Voltage at the end.
E4
Index Fire Pump Control
Description Page Number
3
0
5
F1
Fire Pump Controller For Electric Driven Fire Pumps
Operator interface:
• 2 line liquid crystal display of all 3 phase to phase RMS voltage and
F current measurements simultaneously
• Real time clock
• RS485 communications
• LED “Power Available”: (Green) Illuminates when all three phase voltage are
greater than 83% of nominal. Extinguishes if one or more phases are below 83%
of nominal. LED will flash for 5 seconds if a brownout condition is detected
• LED “Phases Reversed”: (Red) Illuminates if phases are reversed.
• LED “Locked Rotor Impending Trip”: (Red) Flashes on impending breaker trip
• Test function for motor locked rotor protection. Software test through keypad
combination, will cause Motor Locked Rotor LED to flash. After appropriate time
delay, shunt trip relay of the Motor Protector will energize.
• Test function for Phases Reversed. Software test through keypad combination to
test the phase detection circuit for five seconds.
• Data logging at time of motor start (auto or manual), Motor Stop, Power On and
Power Off
• Tamper proof Membrane keypad for setting clock and recalling data logging
F2
General Information Fire Pump Control
Motor Starting Types Automatic Transfer Switch Modification
Across-The-Line Type D10630 Fire Pump Controllers with Automatic Transfer Switches
The most economical and most commonly used type of fire provide for power connections to the fire pump motor from
pump controller. Full voltage is applied to the motor for the primary power source or an alternate power source.
srarting, by use of a single motor contactor. Starting inrush If the primary power fails, the transfer switch automati-
is approximately 600% of rated motor full-load amperes. cally switches to the emergency source. Automatic
retransfer to primary power source occurs after restora-
Autotransformer Type D10640 tion of normal power.
The motor circuit voltage is reduced by autotransformer The alternate source may be an emergency generator or
action during the motor starting period. A line contactor by- second utility supply. Circuit requirements differ for each
passes the autotransformer after a time delay. type, therefore the alternate source must be specified.
Starting line current is 42% of across-the-line starting
The Automatic Transfer Switch is housed in a barriered
inrush approximately 250% rated motor full-load amperes
compartment of the Fire Pump Controller. This complete
with the autotransformer on the 65% tap as shipped from
assembly, consisting of Fire Pump Controller and Auto-
the factory. A 50% and 80% tap can be used.
matic Transfer Switch is factory assembled, wired, tested
and shipped as a single unit.
Primary Resistor Type D10650
A resistor, inserted in the motor line, results in soft starting
and smooth acceleration. A line contactor by passes the
resistor after a time delay. Starting line current is 65-74% of
across-the-line starting inrush approximately 390-444% of
rated motor full-load amperes.
F
Part Winding Type D10670
2-winding type motor required - the first winding is con-
nected to the line to start; the second connected in parallel
by a second contactor, after a time delay. Starting line
current is 65% of across-the-line starting inrush - approxi-
mately 390% of rated motor full-load amperes.
F3
Fire Pump Control General Information
General
Joslyn Clark Diesel Fire Pump Controllers are designed
and listed specifically for diesel engine driven fire pump
service. These controllers meet or exceed all require-
ments of the National Fire Protection Association Standard
NFPA 20, are listed by Underwriters Laboratories Inc., and
approved by the Factory Mutual System.
The diesel controller provides four (4) major functions:
Starts the diesel engine automatically from water
pressure control or nonautomatically from manual
electric control.
Monitors engine as well as system conditions.
Maintains charge on engine starting batteries.
Initiates a weekly test of the system.
Standard Equipment
Type 2 Drip-Proof, Moisture Resistant, lockable
enclosure with break glass panel, is suitable for wall
or floor mounting. Painted with a UL Recognized
F Corrosion Resistant red baked enamel offers
superior resistance to the damp corrosive environ-
ment of pump rooms.
Voltage surge arrester for incoming 120 Volt AC
supply is connected to a line disconnect switch.
Provides an added degree of component pro-
tection against lightning strikes for greater reliability.
Visual indicators and audible alarms are provided to
indicate the following:
Automatic ON Charger Loss
Low Oil Pressure #1 Battery Overcharge
Engine Over Temp #1 Battery Failure
Safety Shut Down #2 Battery Overcharge
Fail To Start #2 Battery Failure
Engine Overspeed
F4
General Information Fire Pump Control
Alarm Panel
General
Joslyn Clark alarm panels provide visual signals and
audible alarms to monitor the status and operation of the
pump controller. A separate, "reliable" source of 115V
supervisory power must be provided to the alarm panel.
Each abnormal condition lights the appropriate light and
sounds the audible alarm. The audible alarm can be push
button silenced, but the light remains lit until the abnormal-
ity is cleared. Signals are independent of each other and
the panel operation will repeat for each new abnormal
condition, regardless of the previous status.
Listed Modifications
Fire Pump Start - This is commonly called "Remote
Start" for starting the main fire pump controller.
Up to three additional alarm lights and silence buttons
may be ordered. Specify name plate markings. Signal
contacts must close for alarm.
3
0
5
Ordering Information
See Price Sheet PS-10600-1
F5
General Information Fire Pump Control
Medium Voltage Type
General
Medium voltage fire pump controllers are primarily used to start large
horsepower motors. These starters are designed for automatic starting of
squirrel cage motors when starting current must be reduced.
Motors starting current at 2300 volts or 4160 volts is considerably below that
at 460 volts. This eliminates many problems that exists when starting large
horsepower motors at lower voltages.
F Construction Details
Enclosures - Free standing, single high, non withdrawable starter
mounted in a NEMA 2 enclosure. NEMA 3R and 12 enclosures
are also available. NEMA 4 design includes an outer shell. The
enclosure is painted, all other parts are plated with corrosion
resistant materials. Type 4X outer enclosure is constructed with
#304 stainless steel.
F6
Index Mill Duty Products
4
0
0
G1
Mill Duty Products Limit Switch
Right Hand Shown
Application
Type 102HL and HLD Hatchway Limit Switches are designed as
pilot circuit devices for all heavy duty applications to limit travel or
set up function at predetermined positions. OnType HL single
acting switches, the lever operates in one direction only; while on
Type HLD double acting switches, it operates in two directions with
a variety of contact sequences.
Features:
Double Break removable Silver-to-Silver Contacts.
Each contact may be independently changed from normally open
to normally closed and vice versa without disassembly.
Operating Arm on most models may be field changed to the other
side by reversing the shaft.
0
Lever Travel is 50 Oil impregnated bearings at contact finger pivot points.
Each Direction Oil impregnated shaft bearings need no lubrications.
Ordering Information
Use complete catalog number when ordering. If modification is required, state in full detail on the order.
Modifications:
Omit standard lever and roller, . . . . Deduct $ 24.
Phenolic composition roller, 21/2" dia., on standard lever in place of standard steel roller, A102-426105A . . . .Add $ 30.
Five-inch lever with standard steel roller, in place of standard lever and roller, A102-248096A . . . Add $ 162.
Seven-inch dia., composition roller on 5" lever, in place of standard lever and roller, A102-75993A . . .Add $ 294.
1 HLD-9 $ 858.
2 HLD-10 936.
12 lbs.
2 HLD-11 936.
G
Cams are $38.00 each and included under JC80
HLD-1, 2, 3 & 4 in Standard Enclosure
Contact Sequence HLD-5, 6, 7 & 8 in Dust-tight Enclosure
Cam No. As Supplied Converted To: Spare Parts JC 80
CCW CW CCW CW Movable Contact A101-028965 $26.00
Torsen Spring A101-062988 $25.00
A102-277623 1 Pole Base A102-041256A $90.00
A102-277624 2 Pole Base A102-041255A $156.00
A102-277625 Std. Arm & Roller A102-302350A $122.00
5" Lever with JC32
Contact Closed Contact Open Steel Roller A102-248096A $270.00
Ordering Information
Use complete catalog number when ordering.
Modifications on page G2. If modifications are required, state in full detail on the order.
Operation
The contacts of these switches make and break very quickly due to the
snap action of the toggle type operating mechanism. The operating arm
is secured to a hollow outer shaft that fits over the camshaft. When the
arm is tripped, it turns the outer shaft which actuates the toggle
mechanism. The toggle mechanism does not change position until the
operating lever is past the midpoint of its travel; then it snaps over and
turns the camshaft quickly. Since the cams are fastened rigidly to the
camshaft, they in turn impart snap action opening and closing to the
contacts. Force to operate switch is approximately 25 inch-pounds.
Angular Travel
Total angular travel of the arm from one tripped position to the other is
900. However, the contacts are actuated when the arm moves 600, the
balance of the travel is to clear the arm so that the linear operator may
pass over.
Features:
TLSF-11 or 22 with Straight Fork Lever
Double Break removable Silver-to-Silver Contacts.
Each contact may be independently changed from normally open
to normally closed and vice versa without disassembly.
enclosures are also available for all types.
Contact wearing parts completely interchangeable with
G
Operating Arm adjustable on shaft. same parts in Type 101SD Master Switch, 101FS Foot
Oil impregnated bearings at contact finger pivot points. Switch, and 102HL & CHL Limit Switch.
Cast weatherproof enclosure standard. Dust-tight and watertight
Available Levers:
Part # A102-054262
TLSF Straight
Fork Lever
Part # A102-054261
TLS Rod or
Chain Type Lever
0
3
3
G4
Limit Switch Mill Duty Products
Type TL Snap Action - Limit Switch
Standard Enclosure Dust-tight Enclosure Watertight Enclosure
2 1 1 1
Type Operating Lever Contacts Catalog No. Price Catalog No. Price Catalog No. Price
TLS-11 Rod or Chain 1 A102-80579A-1 A102-80579A-2 A102-80580A
TLS-22 Rod or Chain 2 A102-80581A-1 A102-80581A-2 A102-80582A
TLSR-11 Straight or Roller 1 A102-80591A-1 $ 846. A102-80591A-2 $ 918. A102-80592A $ 1746.
TLSR-22 Straight or Roller 2 A102-80593A-1 A102-80593A-2 A102-80594A
TLF-11 Roller Fork 1 A102-80575A-1 A102-80575A-2 A102-80576A
TLF-22 Roller Fork 2 A102-80577A-1 A102-80577A-2 A102-80578A
TLSF-11 Straight Fork 1 A102-80583A-1 900. A102-80583A-2 972. A102-80584A 1824.
TLSF-22 Straight Fork 2 A102-80585A-1 A102-80585A-2 A102-80586A
0
3
3
Application
Type 102RS Rubber Calender Safety Switch is a pilot circuit
device used chiefly in the Rubber Industry as an emergency stop
arrangement on Calenders, and similar motor driven machinery.
Features:
Gravity Operated.
Double break removable silver-to-silver contacts.
Can be mounted horizontally or vertically.
Oil impregnated shaft bearings need no lubrication.
Contact wearing parts completely interchangeable with same
parts in type 101SD Master Switches, type 101FS Foot Switches
and type 102HL, CHL, TL Limit Switches.
Dust-tight enclosure is standard.
Rubber Calender
Dust-tight Enclosure
Type Contacts Poles Catalog No. Price 1
RS22 2 NC 2 A102-66750A $ 1224.
0
3
Note: 3
Approximate Dimensions
0
3
3 Note:
1. Price includes limit switch complete with cable, cable weight and
counterweight. Approximate shipping weight is 45 lbs.
Ordering Information
Use complete catalog number.
If dust-tight enclosure is desired, add $66 to the standard enclosure price. Use the same catalog number as for standard enclosure and
specify "Dust-tight" on the order.
Application
The Type 102BST Switch is a pilot device used for special protection
against side movement of conveyor belts.
Operation
One Switch is mounted on each side of the conveyor belt with the lever
mounted roller close to the belt edge. If the belt tends to move either side
due to misalignment of its rollers, the belt edge moves the limit switch
lever arm. After a selected number of degrees of lever
movement the normally open contact in the switch closes. This can
operate a warning system, either a light or audio signal. If the fault is not
corrected and the belt moves the lever arm to large degree, a second
contact, normally closed, will open and shut down the system. The type
BST switch can save untold down time and expense in torn and
damaged conveyor belts. Also when used in conjunction with the Type
RS Safety Limit Switch, they form a team of safety devices that provide
protection to both the operators and belts. The Type BST
Switch uses a NEMA Type 4 Watertight enclosure. The Type BST-22
has an 8" Stainless Steel Roller with Nylon Bushings, mounted on a
lever arm so that the middle of the roller has a 9 3/8" radius.
G
Type 102BST Belt Side Travel - Limit Switch
Shaft Dust tight Enclosure
1
Type Contacts Type Operator Type Catalog No. Price
8" long stainless
BST-22-R 2 Stan- steel roller with A102-351409A-1 $ 1392.
dard nylon bushing
Note:
1. One normally open and one normally closed overlapping contacts.
Lever only A102-463807A $ 820 x JC80
Approximate Dimensions
3
8
0
Features
Double Break removable Silver-to-Silver Contacts. Oil impregnated bearings at contact finger pivot points.
Contact wearing parts completely interchangable Oil impregnated shaft bearings need no lubrications
with the same parts in Type 101SD Master Switch, Mallable iron operating pedal.
and Type 102HL, TL and CHL Limit Switch. Spring return standard.
Each contact may be independently changed from Cast Weatherproof enclosure standard.
NO to NC and vice versa without disassembly.
3
8
0
G9
Mill Duty Products Master Switch
Contact Symbols
A B C D E F
Note:
1. Price includes switch complete with operating pedal.
2. Page G12 for Dimension reference and shipping weight.
3. Overlapping Contacts:
Standard switches provide for only one contact closed at a time. If overlapping is required, one contact must close before the other contact
opens. Type FSA-330 switches have overlapping contacts. If the degree and/or point of overlap is not specified, price in quantities of 1 or more
0
is $ 738. If purchaser specifies degree and/or point of overlap: Price in quantities of 5 or less is $900.00. Price in quantities of 6 or more is 3
$738. 3
FRSA-22 2 1 forward, 1 reverse --- Double treadle foot Horizontal R.H. or L.H. A101-62267A 1110. 3
and an off point pedal for reverse
operating
Only G
Contact Symbols
A B C D E F
Notes:
0 1. Price includes switch complete with operating pedal.
3
2. Page G12 for Dimension reference and shipping weight.
3
Dimensional Information
Reference No. 1 - Horizontal
Reference Weight
No. 1 12 lbs.
No. 2 12 lbs.
No. 3 15lbs.
3
8
0
G12
Master Switch Mill Duty Products
Type 101SD Master Switches are designed as pilot circuit devices for
frequent operation with minimum maintance on heavy duty application in all
industries. The type SD units are sturdy devices constructed for heavy duty
service where few control circuits are required. Type SD Switches are made
in two frame sizes:
Type SD-2 is a single point device, one point either side of the off point, and
there are two isolated contacts which can be opened or closed in various
combinations.
G
Mill Master Jr. - Master Switch
Standard Operation
Number of No. of Surface Mounting Dim. Panel Mounting Dim.
1 2
Type Operating Points Cir- Reversing Catalog No. Price Ref. Catalog No. Price Ref.
cuits
1 (each direction) yes A101-88359A A101-88360A
SD-2 2 $ 798. A $ 1272. C
1 (one direction only) no A101-88363A A101-88364A
Spring Return Operation
1 (each direction) yes A101-88361A A101-88362A
SD-2-S 2 1080. A 1512. C
1 (one direction only) no A101-88365A A101-88366A
Notes:
1. Price includes master switch in watertight enclosure complete with operating handle.
2. Price includes master switch in watertight enclosure complete with metal pistol grip handle, steel
mounting plate and standard anualar name plate. Specify nameplate markings; standard nameplate
provides one marking for each point of the switch.
Advise detailed cam development for each switch. Refer to page G14 for diagram of standard cam
development.
Ordering Information:
Use complete catalog number when ordering.
3 Dimensional reference on page G14
8
0
Spring Return
A&C 15 lbs.
Dimensional Information
ON ON REV. FOR.
1 1 1
2 2 2
3
8
0
G14
100 Series
Mill Type Push Buttons (Heavy Duty)
Type H Assembled
Features:
Heavy cast enclosure and mushroom operating head.
Oil impregnated bushing.
Heavy duty Type H push button element with double break
silver-to-silver wipe action contacts.
Large electrical clearance.
Push button stop independent of contacts. All shock ab-
sorbed by the cast case.
All parts removable and replaceable with a screwdriver. Type H Form RN Type H Form RNG
Unprotected With Guard Ring for
Palm Operation
Type H - Momentary Contact
Form RN - Without Guard Ring Form RNG - With Guard Ring
2
Name Plate Contacts Contact Catalog Catalog
Symbol Number Price 1 Number Price 1
Marking Available
None 1 N.O. and 1 N.C. 1 1RN-1 $ 258. 1RNG-1 $ 258.
None 2 N.O. and 2 N.C. 4 1RN-2 300. 1RNG-2 300.
Start 1 N.O. and 1 N.C. 1 1RN-3 258. 1RNG-3 258.
Stop 1 N.O. and 1 N.C. 1 1RN-4 258. 1RNG-4 258.
Emer Stop
On
1 N.O. and 1 N.C.
1 N.O. and 1 N.C.
1
1
1RN-5
1RN-6
258.
258.
1RNG-5
1RNG-6
258.
258.
G
Off 1 N.O. and 1 N.C. 1 1RN-7 258. 1RNG-7 258.
Forward 1 N.O. and 1 N.C. 1 1RN-8 258. 1RNG-8 258.
Reverse 1 N.O. and 1 N.C. 1 1RN-9 258. 1RNG-9 258.
Jog 1 N.O. and 1 N.C. 1 1RN-10 258. 1RNG-10 258.
Jog Forward 1 N.O. and 1 N.C. 1 1RN-11 258. 1RNG-11 258.
Jog Reverse 1 N.O. and 1 N.C. 1 1RN-12 258. 1RNG-12 258.
Reset 1 N.O. and 1 N.C. 1 1RN-13 258. 1RNG-13 258.
Run 1 N.O. and 1 N.C. 1 1RN-14 258. 1RNG-14 258.
Slow 1 N.O. and 1 N.C. 1 1RN-15 258. 1RNG-15 258.
Fast 1 N.O. and 1 N.C. 1 1RN-16 258. 1RNG-16 258.
Up 1 N.O. and 1 N.C. 1 1RN-17 258. 1RNG-17 258.
Down 1 N.O. and 1 N.C 1 1RN-18 258. 1RNG-18 258.
Start 2 N.O. and 2 N.C. 4 1RN-19 300. 1RNG-19 300.
Stop 2 N.O. and 2 N.C. 4 1RN-20 300. 1RNG-20 300.
Emer Stop 2 N.O. and 2 N.C. 4 1RN-21 300. 1RNG-21 300.
Note:
1. Price includes assembled push button station complete with element Contact Blocks
and nameplate as designated. INO & INC BA $ 62.00 JC80
2. With Name Plate at top, case may be turned so that Conduit 2NO & 2NC BB $104.00 Discount
Opening is at top or bottom. Schedule
Contact Symbols
4
1
0
H1
DP - Definite Purpose Control AC Contactors
H
Application Low Coil Inrush and Sealed VA Interchangeable
Definite Purpose Contactors are Provides maximum efficiency, Along with being compact in size,
intended for use in applications where permitting potential cost savings on the mounting plate is designed to
the control requirements are well transformer requirements. This facilitate proper alignment and
defined. They are not recommended efficient magnet system assures interchangeability with practically all
for general industrial use. clean pick-up and drop-out without competitive 2 pole contactors. Also,
As a magnetic motor controller, they chattering when subjected to slowly the low v-a permits direct inter-
are inductively rated for both rising and slowly decreasing voltages. changeability without requiring a
maximum continuous current and transformer change.
maximum locked rotor current Versatile Operating Positions Terminals
Resistive ratings apply to resistive Joslyn Clark 2 pole contactors are As an optional feature, Joslyn Clark
heating applications only. designed to operate effectively in the contactors can be supplied with
Joslyn Clark definite purpose vertical, horizontial or tabletop pressure clamp terminals which are
contactors have been specifically mounting positions. This gives design UL Recognized for field connec-
designed for use with air conditioning, engineers maximum versatility for tions of #14 through #8 copper
heating and refrigeration control designing low cost systems. wire. They may also be supplied
equipment. They are suitable for other with box lugs for #4 through #14 Al/
non cycling duty applications requiring Cu wire.
reliable low cost switching. Up To 600 Volts A-C Rating
The 2 pole contactors have been
designed with the customer in
4
mind. They provide clearance 1
between terminals permitting total 0
utilization of all quick connects
without requiring special insulation
between terminals on equipment
rated up to 600 volts.
H2
DP - Definite Purpose Control AC Contactors
2 Pole Contactors - Type DP2
20, 25 and 30 Ampere (Discount Schedule JC54)
Amp. Ratings
Type FLA Res LRA Volts Model Number Catalog Number Price
20 30 100 240/277
10 25 50 480 DP2C202- * A77-306680A- * $ 31.00.
10 25 50 600
25 30 125 240/277
10 25 50 480 DP2C252- * A77-306658A- * 39.00.
10 25 50 600
DP2
25 35 150 240/277
1 1
21 35 125 480 DP2HC252- * A77-306660A- * 41.00
17 35 100 600
30 40 150 240/277
1 1
15 40 75 480 DP2C302- * A77-306657A- * 43.00
12.5 40 60 600
Reversing Contactors - Mechanically & Electrically Interlocked Type DP33 - Bulletin 7735
25, 30 & 40 Amp.
Current Ratings Maximum 3 Phase Horsepower Ratings
No. of
Type
Amp. Rating Locked Rotor Amps. General Duty Jogging Duty
Aux. H
Ind. Res. 240V 480V 600V 200V 240V 460/575V 200V 240V 460/575V Model No. Catalog No. Contacts Price
2 $421.00
25 30 150 125 100 5 7 1/2 15 3 3 7 1/2 DP33C253- * A77-350735A- *
4 494.00
DP33 5 5 2 470.00
30 40 180 150 120 7 1/2 10 15 7 1/2 DP33C303- * A77-350737A- *
4 543.00
10 10 5 7 1/2 2 527.00
40 50 240 200 160 25 15 DP33C403- * A77-352100A- *
4 599.00
Approvals
Underwriters Laboratories, Inc. recognized component Canadian Standards Associations (CSA) Guide
for air conditioning, refrigeration and resistance 361-E-0.2 Class 1222 File 18156-55
heating equipment. File number E6591, Section 27.
Guide number NLDX2.
4
2
2 Ordering Information Coil Table
Use complete catalog number. Replace Engineering Data Page H6. Model No. Cat. No.
the (*) with the suffix from the coil table. Modification Page H5. 50/60Hz Voltage 2 Aux. 4 Aux 2 Aux. 4 Aux.
120 120 120CC 1 4
208-240 240 240CC 2 5
Example: DP33C253-120 (A77-350735A-
24 24 24CC 3 6
1) is a 3 Phase, 25 amp., reversing 480 480 480CC
contactor with120V, 50/60 HZ coil and
SPDT auxiliary.
Types DP2, DP3, DP5, DP, DP33, and DP3S Accessories & Parts Kits Discount Schedule JC50 2
Type DP2 Type DP3, DP33 Type DP5
20, 25 & 30 Ampere 25, 30, & 40 Ampere 50 & 60 Ampere
Descrip- Catalog
Catalog Catalog
tion Number Price Number Price Number Price
SPDT Auxiliary Contact Kit ---- ----
KHP-C 2 $ 39.00
N.O. Auxiliary Contact Kit ---- KDP5-10 $41.00
---- ---
N.O. & N.C. Auxiliary Contact ---- KDP5-11 61.00
Kit ----
Contact Cover A77-356577A-1 $ 4.00 A77-356577A-2 4.00
----
Pressure (Box) Lug Kit A77-352648A 7.00 A77-352648A 7.00
(Contains 3 Lugs)
1
Field Modifications
Cat. No. Price Discount Schedule
Notes:
1. Additional modifications may be selected from NEMA HP Section C page C7
2. JC12 Discount Schedule for KHP-C.
3.13
3.75
3.25
4
1.5 3.97 1
2 0
6 mtg. holes/
slots
for #10 screws
Approvals
Underwriters Laboratories, Inc. recognized component Canadian Standards Associations (CSA) Guide Number
for air conditioning, refrigeration, and resistance heating 361-E0.2, File Number LX18156-39.
equipment. File Number #E6591. Guide Number NLDX2.
H6
DP-Definite Purpose Control Engineering Data
Dimension - DP33 (Two 3-Pole Mechanically & Electrically Interlock Contactors)
Typical wiring diagram for Electrically held Reverser using Mechanically Interlocked Push Buttons. H
Electrically Held Contactors and Mechanically
Interlocked Pushbuttons Using Two SPDT
Auxiliary Contacts.
Coil Characteristics
4
Coil D-C Approvals 1
Volts Inrush Sealed Pick-up Resistance 0
Underwriters Laboratories, Inc. recognized
50/60Hz VA VA Volts Ohms component for air conditioning, refrigeration and
24 48 8.4 16 6.5 resistance heating equipment. File number
120 48 8.4 80 170 E6591. Guide number NLDX2.
208-240 48 8.4 160 680
Coil insulation - Class B Canadian Standard Association (CSA) Guide
Coil connections - Double male 1/4" quick connect number 361-E0.2, File number LX18156-39.
Maximum ambient - 155oF
H7
Index DC Control
J1
DC Control 146 Field Loss Relay
Series 146 Relays provide excellent protection against overspeeding on
DC shunt or compound wound motors in the event of an open circuit in the
field. The relay coil is connected in series with the shunt field while the re-lay
motor contacts are in the motor control circuit. The relay coil is de-energized
if the field opens and the relay contacts open to disconnect the motor from
line. Where shunt or compound wound motors are operated at light loads or
not rigidly connected to the load, field loss relays provide protection against
motor and load damage from overspeeding. The Series 146 Relay is a UL
recognized component.
Coils are designed to carry maximum field current continuously. Relays are
factory adjusted to pick-up at one tenth of the maximum field current amps.
listed. Drop-out is approximately 62% of the pick-up value. Other pick-up
values on special order.
0
1
3
Ordering Information
Use complete catalog number when ordering.
Contact Rating: Single pole double break normally open contacts, rated at 0.7 amps., 250 V DC Max.
J2 Discount Schedule JC 21
5DP Contactors DC Control
5DP Definite Purpose Contactors are designed for DC adjustable contactor may be required to interrupt up to 200% current. The N.O.
speed drive circuits using silicon controlled rectifier switching and contacts are equipped with permanent magnet blowouts to meet this
other controls where a combination of normally open and normally requirement.
closed power contacts are required. In all applications, reduced
panel space for contactor mounting is made possible through a The dynamic brake N.C. contact is required to insert the dynamic
compact design and the built-in N.C. dynamic brake power contact brake resistor and therefore must make up to 200% of rated current
feature. each time the contactor is deenergized.
In silicon controlled rectifier switching circuits, the SCR is normally Jogging is accomplished at low voltage and current. Therefore, the
phased back prior to contactor opening. Therefore, the N.O. contacts dynamic brake contact is rated at 1/3 of rated voltage and dynamic
are not required to interrupt any appreciable current. Under abnormal brake current. The permanent magnet blowouts provide this inter-
conditions such as failure of the SCR or the control circuit, the rupting ability.
1. Normally Closed Double Break Power Contacts - made of silver 6. Molded Coil - is layer wound, designed for continuous duty service.
cadmium oxide furnish "anti-weld" protection under overload conditions. Coil construction resists moisture; thermal and mechanical stress. Coil
Generous size contacts are long lasting, and maintenance-free. All N.C. connections are made to pressure type terminals.
power contacts supplied with permanent magnet blowouts to lengthen 7. Free-Floating Armature-Magnet Frame - provide quiet, low vibra-
contact life. tion, low friction operation. Precision ground pole faces achieve an
2. Normally Open Double Break Power Contacts - incorporate the absolute air gap which prevents "hanging-up". Magnet frame is sized
same design features as the normally closed power poles. Permanent for fast, powerful operation and self-seating extends operational life.
magnet blowouts are also furnished on d.c. load applications. 8. Auxiliary Contacts - for 10/40 amp. contactors are available with with
3. Permanent Magnet Blowouts - mounted to surround the power either the front mounted snap action type with quick connect terminals
contacts, function to quickly quench the arc when breaking loads, or the side mounted type with pressure terminals. Contacts for larger
thereby increasing contact life and assuring positive load circuit interrup- sizes in standard or special make-before-break contact combinations
ton. All normally closed poles are furnished with permanent magnet feature either standard double break silver-to-silver contacts or low
blowouts. Normally open poles can be supplied with or without blowouts power gold alloy contacts.
as indicated in the circuit symbols shown on page J6. 9. Pressure Type Terminals - accessible, up-front location permits
4. Stainless Steel Springs - maintain exact contact pressure and modern straight-thru wiring. Terminals accept stripped, unlugged wires.
assure fast contact break (N.O.) and make (N.C.).
5. Molded Housing - constructed of hot-molded, high impact, high arc
resistant insulating material. This design totally encloses the contacts
and operating magnet in separate compartments and functions to
eliminate internal phase-to-phase short circuits.
J3
DC CONTROL 5DP Contactors
SCR Drive Contactors - N.O. or N.C. Power Poles
Drive Contactors Preferred Style 500 VDC Max
Type & Poles Open Type Drive Contactors - Old Style
Rating N.O. N.C. Fig.No. Catalog No. Price For New Installations Use Preferred Style
7001 0 1 7A 7001-5150- * * $208.
Type & Poles Open Type
0 2 9 7001-5230- * * 269.
Rating N.O. N.C. Fig.No. Catalog No. Price
40 1 0 1 7001-6050- * * 179.
7000 0 1 7A 7000-5150- * * $ 208.
amp. 2 0 3 7001-7030- * * 227.
10/40 2 0 3 7000-7030- * * 227.
2 1 10 7001-7140- * * 296. 2 1 10 7000-7140- * * 296.
amp.
5DP7 0 1 7A 5DP7-5150- * * 756. 0 1 8 5DP1-01( *)00 416.
0 2 9 5DP7-5230- * * 1040. 0 2 9 5DP1-02( *)00 491.
5DP1
75 1 0 1 5DP7-6050- * * 693. 1 0 1 5DP1-10( *)00 378.
amp. 2 0 3 5DP7-7030- * * 924. 1 1 5 5DP1-11( *)00 441.
30 2 0 2 5DP1-20( *)00 403.
2 1 10 5DP7-7140- * * 1210.
amp. 2 1 6 5DP1-21( *)00 466.
5DP3A 0 1 8 5DP3A4001-* * 895.
2 0 3 5DP1-5021- * * 441.
0 2 9 5DP3A3071-* * 1323.
2 1 7 5DP1-5051- * * 504.
110 1 0 1 5DP3A4011-* * 857.
0 1 8 5DP2-01( *)00 630.
amp. 2 0 3 5DP3A5021-* * 1176. 0 2 9 5DP2-02( *)00 920.
2 1 15 5DP3A5091-* * 1502. 1 0 1 5DP2-10( *)00 605.
5DP2
5DP4 0 1 8 5DP4-4001- * * 1222. 1 1 5 5DP2-11( *)00 857.
0 2 9 5DP4-3071- * * 1812. 2 0 2 5DP2-20( *)00 794.
56
180 1 0 1 5DP4-4011- * * 1058. 2 1 6 5DP2-21( *)00 895.
amp. 2 0 3 5DP2-5021- * * 832.
amp. 2 0 3 5DP4-5021- * * 1533.
2 1 15 5DP4-5091- * 2104. 2 1 7 5DP2-5051- * * 935.
* 0 1 8 5DP3-01( *)00 895.
5DP9 0 1 8 5DP9-4001- ** 1676. 5DP3 0 2 9 5DP3-02( *)00 1323.
0 2 9 5DP9-3071- ** 2405. 1 0 1 5DP3-10( *)00 857.
260 1 0 1 5DP9-4011- ** 1481. 110 1 1 5 5DP3-11( *)00 1176.
amp. 2 0 3 5DP9-5021- ** 2066. 2 0 2 5DP3-20( *)00 1109.
amp.
2 1 2 1 6 5DP3-21( *)00 1439.
15 5DP9-5091- ** 2793.
2 0 3 5DP3-5021- * * 1172.
5DP5 0 1 8 5DP5-4001- ** 3024.
2 1 7 5DP3-5051- * * 1502.
0 2 9 5DP5-3071- ** 4788.
0 1 8 5DP4-01( *)00 1222.
360 1 0 1 5DP5-4011- ** 2772.
5DP4 0 2 9 5DP4-02( *)00 1817.
amp. 2 0 3 5DP5-5021- ** 4410. 1 0 1 5DP4-10( *)00 1058
J 5DP8
2
0
1
1
15
8
5DP5-5091-
5DP8-4001-
**
**
6048.
3402.
180 1
2
1
0
5
2
5DP4-11( *)00
5DP4-20( *)00
1628.
1470
amp.
0 2 9 5DP8-3071- ** 5544. 2 1 6 5DP4-21( *)00 2041.
535 1 0 1 5DP8-4011- ** 3150. 2 1 7 5DP4-5051 * * 2104.
amp. 2 0 3 5DP8-5021- ** 5040.
0 1 8 5DP9-01( *)00 1676.
2 1 15 5DP8-5091- ** 7497. 5DP9 0 2 9 5DP9-02( *)00 2405.
5DP6 0 1 8 5DP6-4001- ** 5040. 1 0 1 5DP9-10( *)00 1481.
0 2 9 5DP6-3071- ** 9576. 260 1 1 5 5DP9-11( *)00 2192.
700 1 0 1 5DP6-4011- ** 4410. amp. 2 0 2 5DP9-20( *)00 2003.
amp. 2 0 3 5DP6-5021- ** 7938. 2 1 6 5DP9-21( *)00 2730.
2 1 15 5DP6-5051- 11970. 2 1 7 5DP9-5051- * * 2797.
**
0 1 8 5DP5-01( *)00 3024.
5DP5
* Coil Table #1 Replace * with appropriate coil voltage digit. 0 2 9 5DP5-02( *)00 4788.
1 0 1 5DP5-10( *)00 2772.
60 Hz/Voltage ( ) DC/Voltage ( ) 360 1 1 5 5DP5-11( *)00 4410.
* * amp. 2 0 2 5DP5-20( *)00 4032.
120 1 115 8 2 1 6 5DP5-21( *)00 5670.
240 2 230 9 2 1 7 5DP5-5051- * * 6048.
5DP8 0 1 8 5DP8-01( * )00 3402.
0 2 9 5DP8-02( * )00 5544.
* * Coil Table #2 Replace ** with appropriate coil voltage suffix
1 1 5 5DP8-11( * )00 5040.
535
2 0 2 5DP8-20( * )00 4662.
60 Hz/Voltage Suffix DC/Voltage Suffix amp. 4
2 1 6 5DP8-21( * )00 7119. 8
2 1 7 5DP8-5051- * * 7497. 5
120 11 12 72 0 1 8 5DP6-01( *)00 5040.
208/240 21 24 82 5DP6
0 2 9 5DP6-02( *)00 9576.
208 90 48 32 1 0 1 5DP6-10( *)00 4410.
240 21 120 12 700 1 1 5 5DP6-11( *)00 8442.
480 41 240 22 amp. 2 0 2 5DP6-20( *)00 7434.
600 51 2 1 6 5DP6-21( *)00 11466.
Symbols: N.O. Contact Contact with Blowout N.C. Contact + Positive Polarity
Contacts without blowouts do not have any interrupting rating. Contactors with 2 N.O. contacts and blowouts will interrupt 200% current under
abnormal conditions.
Note:
1. Contact Kits for 1-pole include stationary contacts, movable contacts 5. Power pack assembly kit includes rectifier, economizing resistor and
and contact spring except as noted for 700 amp. size. terminal block. Power Pack Kit must be used on all DC operated 5DP6 units
2. Assembled kit for 1-pole including yoke with movable contacts and 6. Values measured at rectifier power pack input.
springs; stationary contacts. 7. It is necessary to phase back the SCR's so that contactor normally
3. For all pole combinations except 2-pole N.C. does not interrupt appreciable current. Contactors with blowouts and
4. These coils are for exact replacement at operating voltage and 2 N.O. contacts will interupt 200% current under abnormal conditions.
frequency listed.
4
5
5
J7
General Information DC Control - 7400
4
8
5
Ordering Information Coil Table
Use complete catalog number. AC 60Hz/Voltage Suffix DC Voltage Suffix
Replace the (*) with the suffix from 120 11 24 82
the coil table. 208/240 21 48 32
480 41 120 12
600 51 240 22
DIMENSIONS - Approximate
(Contactor base must be mounted vertically) J
Fig. 1. Vitrohm pressed steel rheostat Fig. 2. 8" Vitrohm rheostat, Fig. 3. 8" Vitrohm rheostat,
for front-of-board mounting. Type S standard contacts, Type M multi-step contacts,
front-of-board mounting. front-of-board mounting.
STANDARD SIZE RHEOSTATS - 6", 8", 13" MOTOR DRIVE ACCESSORIES-Type SMD
TYPES S and M
APPLICATION
APPLICATION
Type SMD Accessories are for use with 8" or 13" rheostats
Vitrohm pressed steel rheostats furnish a simple, accurate where motor driven operation is required. Standard assem-
and economical method of field control. They are universally blies can be applied to drive up to four plates simultaneously.
applied for adjusting generator, alternator and exciter field cur- For larger 15 1/2" and 18" rheostats as well as the 13" size, a
rents to obtain variations in output voltage and for field control Type LMD large motor drive is available on order.
of adjustable speed D.C. and synchronous motors. Other typi-
cal applications include heater, furnace, battery charging and TO ORDER RHEOSTATS
other controls. * Consult Factory for price and availability
* If replacing and existing unit have the "K" number or serial
J 4" RHEOSTATS-300 Volt Max. Service number available.
J10
Index Relays
4
2
0
K1
PM - Relays General Information
The Joslyn Clark PM Family of control relays provides flexibility, versatility and reliability.
The exclusive design concept and rugged construction of the PM line offers many
advantages for the disigner and builder of today's complex control panels.
Features:
Modular Construction -allows field additon, replacement or Interchangeability of Parts - reduces inventory requirements.
conversion of poles for unlimited flexibility. Flexibility of Application - provided by many modifications
Uniformity of Design -simplifies engineering, installation including noble metal, gold bonded, anti-weld and overlapping
and maintenance. contacts.
K
Convertible Poles contain one contact, Universal Poles contain two independ- Duplex Poles contain two independent
either NO or NC and can be easily field ent isolated contacts, one NO and isolated contacts, both NO. Identified
converted from one to the other. one NC. Identified by RED operating by GREEN operating rod.
Identified be WHITE operating rod. rod.
4
2
0
PMS Slim Jim Relays are 1 - 1 1/2" wide. They are the smallest PM Convertible Pole Relays use white rod poles and are offered
members of the PM Family. Available with up to 4 contacts; with up to 8 contacts in any combination of NO and NC contacts.
they provide the reliability of heavy duty 600 Volt relays in the Relays with up to 12 contacts using double deck bases can be
smallest possible space. supplied.
K2
General Information Relays - PM
Type PMT Pheumatic Timing Relays, these relays are available for
either "on-delay" operation (time delay after energization) or "off-
K
delay" (time delay after de-engerization). They may also be field
converted from on to "off-delay" and vice versa, by merely
inverting the opertaing magnet. Type PMT Time Delay relays are
adjustable over a timing range from 0.2 seconds to 3 minutes with
repetitive accuracy of + 10%.
4
2
0
Latch Relays are available with either white rod convertible poles
or red rod universal poles. The latching unit with continous duty
trip coil replaces the two pole modules directly above the relay
magnet.
K3
PM - Relays AC Relays
Type PM Convertible, PMA Universal, PMF Duplex
Ordering Information
Use complete catalog no. replace the (*) with suffix from coil Table, (Located on Page K5)
1
Maximum of 8 contacts only on 25 hz.
2
Relay Enclosure P6E-01 $80.00
PMF relays with N.C. contacts have universal red
rod & duplex green rod poles. Maximum of 8
3
contacts only on 25 hz. K
Price includes open type relay complete with
operating coil. Latching relays include latch unit
with continuous duty trip coil.
4
Overlapping contacts are available at $120.00 list per
pair. Specify when ordering.
5
For Dimensions, refer to page K7 For modifica-
ion Kits, refer to page K11.
6
Additional relays with alternate pole configurations
available.
Contact Arrangement
Universal Pole -
Red Operating
Rod
Convertible Pole -
White Operating
K Rod
Convertible Pole -
1 Contact either N.O or N.C.
White Operating Rod
4
2
0
K6
Dimensional Data
K
PMS - Relays AC Relays
4
2
0
1
Price listed for relay base includes magnet coil and mounting
plate, less poles.
4
3
0
NEMA Type 4 & 12 Enclosure
Renewal Parts Kits for BUL. 7305 Type PM Convertible Pole Relays Cat. No. Price
Contact Arm, Short (4 Pole) with screws KPM-7 23.
4 Contact Arm, Long (6 Pole) with screws KPM-8 32.
2 Assembled Magnet and Rod (Straight-End Bracket) A-c Relays KPM-9 152.
0
Assembled Magnet and Rod (Hooked-End Bracket) A-c Relays KPM-10 152.
Assembled Magnet and Core. 2,3 & 4 Pole D-c Relays (Includes Rod, Bracket
& Contact Arm) KPM-16 173.
Assembled Magnet and Core, 6 & 8 Pole D-c Relays (Includes Rod, Bracket
& Contact Arm) KPM-17 179.
Renewal Parts for BUL. 7313 Type PMT Timing Relays
Assembled Magnet and Rod (Folio 2 Relays) KPMT-10 301.
Timing Head (without dial) (Folio 2 Relays) KPMT-12 524.
Note:
1
Numbers in pole locations shown in sketches Relay pole connot be
indicate the sequence in which normally closed located here.
poles are mounted when required.
2
Normally open contacts may be changed in the
field to normally closed and vice versa, using only
4 a screw driver.
2
0
0
2
3
Ordering Information Coil Table DC Voltage
Use complete catalog number. Replace Price addition of $30 DC Voltage Suffix
the (*) with the suffix from Coil Table. per relay. For 95 120 120
Overlapping contacts are available in the volt coils , use coil 240 240
same contact block at $108 per pair suffix 95. $150 set
For timer with dial, specify "with dial." up charge for 5 or
Add (each) $60. less units
D-C Applications
D-C Relays
X - Economizing electrical interlock (used in coil circuit) K
Amperes Interrupting Rating is one contact of standard universal pole.
Resistive Load Typical connection of three terminal coil is shown.
Non-Inductive Inductive Load
Volts N.O. N.C. N.O. or N.C.
"ON-DELAY" "OFF-DELAY"
64 or less 10 10 2.2 (Time Delay after denergization)
(Time Delay after energization)
120 8 6 1.1
240 2 1 .55
A-C Applications
Volts Make Break
110 60 6
220 30 3
440 15 1.5
550 12 1.2
0
2
3 Ordering Information Coil Table DC Voltage
Use complete catalog number. Replace Price addition of $30 DC Voltage Suffix DC Voltage Suffix
the (*) with the suffix from Coil Table. per relay. For 32 & 12 12 95 095
Overlapping contacts are available in the 64 volt coils , use 24 24 120 120
same contact block at $108 per pair coil suffix 32 or 64. 48 48 240 240
For timer with dial, specify "with dial" $150 set up charge
Add (each) $60. for 5 or less units
FRONT Hm
DC Contact Rating - P600
Amperes Volt Amperes 2 Continuous
H
Volts Make Break Make Break Amperes
125 1.1 1.1 138 138 5
2
300 Volts or Less
4
3
0
PMT-DC 714UP 6 1/8 3 3 1/8 4 1/2 2 1/2
713UP-DC 1,2-Pole 5 1/2 3 3 3/8 4 1/2 2
713UP-DC 3 Pole 5 1/2 3 3/4 3 3/8 4 1/2 2
713UP-DC 4 Pole 5 1/2 4 1/2 3 3/8 4 1/2 2
K16
Coil Data Relays - PM
Standard catalog listed AC relays ordered basic and latch relays except the Slim Jim, first factor. As shown in Table 1, one coil for
will have the proper coils as determined by determine the mechanical load on the magnet each voltage and frequency will operate all
the voltage and frequency suffix to the simply by totalling the load represented by the pole combinations.
catalog number. individual components operated by the magnet,
Changing the circuit arrangement on a relay using the mechanical load factors shown below.
also changes the mechanical load on the Select the proper coil from Table 1.
magnet and may require a change of When selecting the proper coil for Slim Jim
operating coil to assure proper operation. Relays and Time Delay Relays, it is not
the information on this page will enable you necessary to determine the mechanical load
to select the correct operating coil for any
circuit arrangement required. Voltage- Mechanical Load Factors:
ampere requirements are provided to help in Convertible Pole - Normally Open ................................................................... 10
designing your panels. Convertible Pole - Normally Closed ................................................................. 12
To select the proper operating coil for all Double Contact Pole - Universal or Duplex ..................................................... 36
Latch Mechanism ............................................................................................. 20
Example:
For Example: A relay with 1 N.O. and 9 N.C.
Table 1 indicates that the proper coil convertible poles and a latch
number for 110 volts, 60 hertz application mechanism will have a mechanical
is TB113-61, since the load factor of 168
load factor as follows:
falls within the Mechanical Load Range of
1 N.O. Convertible Pole .............................................................................. 10
145 to 192.
9 N.C. Convertible Poles .......................................................................... 108
Accumulation Factor 1 ............................................................................................................... 30
1 Latch Mechanism ..................................................................................... 20
Total Mechanical Load Factor .................................................................. 168
1
For relays with 9 or more normally closed convertible poles, an accumulation factor of 30 must be added to to the total
mechanical load factor for the relay
K17
447 Relays Control Relays
Description
Series 447 relays are designed for AC and DC circuits where high reliability, versatility of contact and operating coil combinations,
compact size, and high speed operation are required. The 447 relays are available up to 8 convertible poles, current ratings to
30 amps AC and 20 amps DC.
4 Pole Base- 115 VDC Coil 1 447-9405.13 276. Unit Poles - DC Load (Table 3)
230 VDC Coil 447-9405-23 276. 250VDC Max
8 Pole Base- 115 VDC Coil 2 447-9805-13 380. Description 4 Cat. No. Price
230 VDC Coil 447-9805-23 380.
20A, N.O. 1-Blowout 447-9019 $66.
1
Heavy Duty Coil, Suitable For Up To 4 Circuits 20A, N.O. 2-Blowout 447-9020 72.
2
Heavy Duty Coil, Suitable For Up To 8 Circuits 20A, N.C. 1-Blowout 447-9021 66.
8-Pole Base 20A, N.C. 2-Blowout 447-9022 72.
Note: Other AC and DC coil voltages are 4
All DC contacts require a "Blowout
available. Please contact factory.
Mechanism" to extinguish the "arc" during
contact opening. See Rule "B" below.
Rules to Select and Install Contacts
A. When installing “AC” or “DC” contacts you should balance the mechanical load on the coil magnet preferably by placing
the contacts together in the center and working your way out.
- For a 4-pole contact install the contacts in sequence per the diagram listed below.
3 2 1 4 K
- For an 8-pole contact install the contacts per this diagram.
5 3 2 1 4 6
8 7
B. When installing DC contacts, using the contact sequence above, the last contact on the left must have two blowouts.
All others will have only one.
Example: If you have four contacts on the 4-pole base (table 1), number 3 must have two blowouts. If you have only two
contacts, then number 2 must have two blowouts.
If you have six contacts on the 8-pole base (table 1), number 5 must have two blowouts.
Contacts seven and eight on the 8-pole base must have two blowouts.
2
5
5
Ordering Information
Select and Price Base and Power Plant and Unit Poles Separately. 1 - 447-9402-11 $ 144.
Example: 120 VAC 4 Pole relay with 2 N.O., 2 N.C., 10 Amp Poles. 2 - 447-9046 88.
2 - 447-9047 88.
Dimensions: See Section L Page 6. $320.
Accessories .................................................................................... M4
M
M
0
1
6
M1
M1
MEK90 Photoelectric Control
MEK 90 Universal and High
Performance Series
User Programmable or Dedicated Controls:
Thru-Beam, Retroreflective, Diffuse Reflective,
Convergent, Fiberoptic Thru-Beam, Fiberoptic Diffuse
Two Built-In Timers
Plug-In control may be replaced without rewiring
User configurable as a Retro, Diffuse, Light Source or
Light Receiver (Thru-Beam)
Two timers included: On Delay, Off Delay, One Shot or
Delayed One Shot may be selected or combined
Two selectable timing ranges: 0-1.5 sec. and 1-15 sec.
Large capacity 6A SPDT Relays, AC FET outputs and
NPN Open Collector outputs are available
Wide range of supply voltages
Optional lens kits for conversion to Convergent Beam or
Fiberoptic in the field
Dedicated factory assembled controls: Polarized Retro,
Fiber Optic, and Dedicated Light Source (Emitter)
Housing environmental integrity is 1, 4, 4X, 12, and 13
Mounting Brackets on page M24
Selection Chart
Universal Control: Provide Retro, Diffuse and Thru-Beam
Output Supply voltage Max. Load Range (Using standard test targets) Catalog No. Price
Relay 102-132 VAC 6A / 240 VAC (res) Retro: 18 ft. Diffuse: 78 in. T-B: 200 ft. MEK90-LUAR 1,3 $ 348.00
Relay 105-264 VAC 6A / 240 VAC (res) Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UAR 348.00
NPN 10-36 VDC 200 mA / 30 VDC Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UDC 348.00
Relay 10-36 VDC 6A / 120 VAC Retro: 18 ft. Diffuse: 30 in. T-B: 200 ft. MEK90-UDR 348.00
Specifications Specifications
Output Response Time
Power Consumption 2VA, 50mA
Relay: SPDT 6A 240VAC (resistive) 28 \VDC <10ms. ON, <8ms. OFF
Materials (Housing) Corrosion Resistant,
FET: SPNO Solid State AC Output 1A @ 250 C, <13ms. ON, 13ms. OFF Fire Retardant ABS
0.5A @ 600 C (<10uA OFF State Leakage) (Lens) Polycarbonate 0
Open Collector: NPN (sinking) 200 mA 30VDC <5ms. ON, <5ms. OFF 1
Environmental Ratings NEMA 3,4,4X,12, and 13 6
Temperature Range -400 to 1580 F -400 to 700 C
Approvals U.L. Recognized C.S.A.
2
Fiberoptic (All Modes) ON OFF ON
1
Refer to page M58 for accessory Converging Bean Lens Kits.
2
Refer to page M58 for accessory Fiberoptic Adaptors: Refer to
page M33 for MEK901 Glass Fiberoptic Light Guides.
0
1
6
M1 M3
Photoelectric Control Accessories
Plastic Corner Cube Reflectors
Catalog No. Dimensions Range Use With:
K-3567 3 in. dia. Long Any Retroreflective, Polarized or Reflective Fiberoptic control
K-3568 1.5 in. dia. Middle Any Retroreflective, Polarized or Reflective Fiberoptic control
K-4305 0.625 in dia. Short Any Retroreflective, Polarized or Reflective Fiberoptic control
Retroreflective Targets
Description Catalog No. Price
Corner Cube Reflector 3" DIA. K-3567 $ 14.
Corner Cube Reflector 1.5" DIA. K-3568 8.
Corner Cube Reflector .625" DIA. K-4305 8.
0
#10 INTERNAL 1
TOOTH 6
LOCKWASHER
(2 INCL.)
#10-32 SLOTTED
HEX WASHER
HEAD SCREWS
(2 INCL.)
M1
N1
Replacement Coils Numerical Coil Data
Description Coil Volts Hertz Price
TB127-1 110 60 $69.00
For Use With Series: TB127-2 220 60 69.00
Description Coil Volts Hertz Load Factor Price LCL20, LCL30, TB127-2 115-230 DC 69.00
TB113-1 110-120 60 20-72 $99.00 PML, PMAL TB127-2 180 DC 69.00
TB127-3 380 60 115.00
For Use With Series: TB113-3 110-120 60 73-144 99.00 (Trip Coil)
TB127-4 380 50 115.00
447, LC20, LC30, TB113-3 110-120 50 145-192 99.00
TB113-4 220-240 60 20-72 99.00 TB127-4 440 60 115.00
PM, PMA, PMF, TB127-5 220-240 25 276.00
TB113.4 277 60 73-144 99.00
PMAL TB113-6 277 60 145-192 99.00 TB127-5 440 50 276.00
TB113-6 220-240 60 73-144 99.00 TB127-5 550 60 276.00
TB113-6 220-240 50 145-192 99.00 TB127-6 440-480 50 276.00
TB113-7 380 50 20-72 99.00 TB127-6 550-600 60 276.00
TB113-7 440-480 60 20-72 99.00 TB127-7 110 50 276.00
TB113-7 550 60 73-144 99.00 TB127-8 110 25 276.00
TB113-7 550 50 145-192 99.00 TB127-8 220 50 276.00
TB113-8 220-240 25 20-96 99.00 TB127-9 550 50 276.00
TB113-9 440-480 60 73-144 99.00 TB127-10 550-600 50 276.00
TB113-9 440-480 50 145-192 99.00 TB127-11 220 25 115.00
TB113-10 550 60 20-72 99.00 TB127-11 440-480 60 115.00
TB113-11 600 60 73-144 99.00 TB127-12 380 25 276.00
TB113-11 600 50 145-192 99.00 TB127-13 440 25 276.00
TB113-13 440-480 50 73.144 99.00 TB127-14 24 60 69.00
TB113-15 277 60 20-72 99.00 TB127-15 12 60 69.00
TB113-16 600 60 20-72 99.00 TB127-19 110 40 276.00
TB113-18 110-120 50 20-72 99.00 TB127-20 110-120 60 69.00
TB113-19 110-120 50 73-144 99.00 TB127-21 220-240 60 69.00
TB113-20 110-120 25 20-96 99.00 TB127-22 110-120 50 276.00
TB113-20 220-240 50 73-144 99.00 TB127-23 110-120 25 69.00
TB113-21 440-480 50 20-72 99.00 TB127-23 220-240 50 69.00
TB113-21 600 50 73-144 99.00
TB113-22 550 40 20-72 99.00
TB113-22 380 25 20-96 99.00 Load
TB113-23 550 50 73-144 99.00 Description Coil Volts Hertz Factor Price
TB113-24 600 50 20-72 99.00 For Use TB130-1 110 60 230.00
TB113-28 380 50 73-144 99.00 With Series: TB130-2 208-220 60 230.00
TB113-32 600 25 20-96 99.00 TB130-3 380 60 230.00
PMT *, PMA,
TB113-33 440-480 25 20-96 99.00 TB130-3 380 60 193-240 230.00
TB113-34 550 25 20-96 99.00 PMF, PMAL
TB130-4 400 60 230.00
TB113-36 24 60 20-72 99.00 TB130-5 550 60 230.00
TB113-37 24 60 73-144 99.00 TB130-5 440 50 230.00
TB113-39 12 60 20-72 99.00 TB130-5 440-480 50 193-240 230.00
TB113-40 12 60 73-144 99.00 TB130-5 550 60 193-240 230.00
TB113-47 48 60 20-72 99.00 TB130-6 600 60 230.00
TB113-48 48 60 73-144 99.00 TB130-6 600 60 193-240 230.00
TB113-51 6 60 20-72 99.00 TB130-7 110 50 230.00
TB113-51 8 60 145-192 99.00 TB130-7 110-120 50 193-240 230.00
TB113-53 8 60 20-72 99.00 TB130-8 208-220 50 230.00
TB113-55 8 60 73-144 99.00 TB130-8 220-240 50 193-240 230.00
TB113-60 24 60 145-192 99.00 TB130-9 380 50 230.00
TB113-61 110-120 60 145-192 99.00 TB130-9 380 50 193-240 230.00
TB113-62 220-240 60 145-192 99.00 TB130-9 440-480 60 193-240 230.00
TB113-63 220-240 50 20-72 99.00
TB113-63
TB113-64
380
380
60
60
145-192
73-144
99.00
99.00
TB130-9
TB130-10
480
550
60
50
230.00
230.00 N
TB130-10 550 50 193-240 230.00
TB113-64 380 50 145-192 99.00 TB130-11 600 50 230.00
TB113-64 440-480 60 145-192 99.00 TB130-11 600 50 193-240 230.00 0
TB113-65 380 60 20-72 99.00 TB130-12 24 60 230.00
2
6
TB113-65 550 60 145-192 99.00 TB130-13 120 60 230.00
TB113-66 600 60 145-192 99.00 TB130-13 110-120 60 193-240 230.00
TB113-71 48 60 145-192 99.00 TB130-14 240 60 230.00
TB113-76 12 60 145-192 99.00 TB130-14 220-240 60 193-240 230.00
TB113-76 6 60 73-144 99.00 TB130-17 42 50 230.00
TB113-77 6 60 145-192 99.00
* NOTE:
TB130 coils are used on Bul. 7313 Timing Relays not marked
"Folio2". This includes original Class A timers and all Class B
timers. See TB135 coils for Class A, Folio 2 timers.
N2 Discount ScheduleM1
JC80
Numerical Coil Data Replacement Coils
Description Coil Volts Hertz Price Description Coil Volts Price
TB135-1 110 60 $108.00 TB140-1 115-120 DC $221.00
For Use With Series: TB135-2 208-220 60 108.00 For Use With Series: TB140-2 230-250 DC 281.00
PMT * TB135-3 380 60 108.00 PMT (DC) TB140-3 260 DC 281.00
TB135-4 440 60 108.00 Folio 2 TB140-4 12 DC 432.00
Discount TB135-5 550 60 108.00 TB140-5 24 DC 432.00
TB135-6 600 60 108.00
Discount TB140-6 72 DC 432.00
Schedule Schedule
TB135-7 110 50 108.00 TB140-7 48 DC 432.00
JC80 JC80 TB140-8 32 DC 432.00
TB135-8 208-220 50 108.00
TB135-9 380 50 108.00
TB135-10 440 50 108.00
TB135-11 550 50 108.00
TB135-12 600 50 108.00
TB135-13 120 60 108.00
TB135-14 110 25 108.00
240 60 108.00
TB135-15 220 25 108.00
480 60 108.00 Substitute TB135-4 for 460V 60 Hz.
TB135-16 24 60 108.00
TB135-17 440 25 108.00
TB135-18 110 40 108.00
TB135-19 12 60 108.00
TB135-20 120 50 108.00
TB135-21 240 50 108.00
TB135-22 480 50 108.00
TB135-23 12 50 108.00
TB135-24 24 50 108.00
Description Coil Volts Hertz Poles Price
TB135-25 208 60 108.00
TB170-1 120 50/60 2, 3, 4 $48.00
* NOTE: For Use TB170-2 208-240 50/60 2, 3, 4 48.00
TB135 coils are used on Bul. 7313 Timing Relays marked "Folio With Series: TB170-3 24 50/60 2, 3, 4 48.00
2". See TB130 coils for timers not marked "Folio 2". DP TB170-4 277 50/60 2, 3, 4 48.00
TB170-5 480 50/60 2, 3, 4 48.00
(Size DP-3)
Description Coil Volts Price TB170-6 600 50/60 2, 3, 4 48.00
Discount
TB137-1 120 DC $248.00 Schedule
For Use With Series: TB137-2 240 DC 248.00 JC53
PM, 447, TB137-3 180 DC 248.00
PMT TB137-4 90 DC 248.00
TB137-5 64 DC 248.00
(DC 2 Lead)
TB137-6 48 DC 248.00
Discount TB137-7 32 DC 248.00 Description Coil Volts Hertz Poles Price
Schedule TB137-8 24 DC 248.00
For Use TB174-1 120 50/60 2, 3 $97.00
JC80 TB137-9 12 DC 248.00
With Series: TB174-2 208-240 50/60 2, 3 97.00
TB137-10 6 DC 248.00
HP/HPF TB174-3 24 50/60 2, 3 97.00
TB137-11 300 DC 248.00
(Size 00-2) TB174-4 277 50/60 2, 3 97.00
TB137-12 120 DC 248.00
Timers Only TB174-5 480 50/60 2, 3 97.00
TB137-13 240 DC 248.00 Discount TB174-6 600 50/60 2, 3 97.00
TB137-14 95 DC 248.00 Schedule TB174-7 380 50/60 2, 3 97.00
JC53
Description Coil Volts Hertz Price
TB139-1 110-120 60 $99.00
For Use With Series: TB139-2
PMS TB139-3
220-240
380
60
60
99.00
99.00 N
TB139-4 440-480 60 99.00
Discount TB139-4 380 50 99.00
0 TB139-6 550-600 60 99.00
2 Schedule
6 TB139-7 64 60 99.00
JC80 TB139-8 48 60 99.00
TB139-9 32 60 99.00
TB139-10 24 60 99.00
TB139-11 12 60 99.00
TB139-12 6 60 99.00
TB139-13 110-120 50 99.00
TB139-14 220-240 50 99.00
Description Coil Volts Hertz Size Price Description Coil Volts Hertz Poles Price
TB162-1 110-120 60 4 $248.00 TB159-1 110-120 60 2, 3, 4 $124.00
For Use TB162-1 110 50 4 248.00 For Use TB159-1 110 50 2, 3, 4 124.00
TB162-2 220-240 60 4 248.00 TB159-2 220-240 60 2, 3, 4 124.00
With Series: With Series:
TB162-2 220 50 4 248.00 TB159-2 220 50 2, 3, 4 124.00
TM -3,4 TB162-3 440-480 60 4 248.00
TM (Size 00,
TB159-3 440-480 60 2, 3, 4 124.00
TB162-3 440 50 4 248.00 0, 1, 2)
TB159-3 440 50 2, 3, 4 124.00
TB162-4 550-600 60 4 248.00 TB159-4 550-600 60 2, 3, 4 124.00
TB162-4 550 50 4 248.00
Discount
TB159-4 550 50 2, 3, 4 124.00
TB162-5 110 25 4 248.00 Schedule
TB159-5 110 25 2, 3, 4 124.00
TB162-6 440-480 25 3 248.00 JC80 TB159-6 220 25 2, 3, 4 124.00
Discount TB162-7 110-120 60 3 207.00 TB159-7 400 25 2, 3, 4 124.00
TB162-7 110 50 3 207.00 TB159-8 550 25 2, 3, 4 124.00
Schedule
TB162-8 220-240 60 3 207.00 TB159-9 24 60 2, 3, 4 124.00
JC80 TB162-8 220 50 3 207.00 TB159-10 200-208 60 2, 3, 4 124.00
TB162-9 440-480 60 3 207.00 TB159-11 380 50 2, 3, 4 124.00
TB162-9 440 50 3 207.00 TB159-13 277 60 2, 3, 4 124.00
TB162-10 550-600 60 3 207.00
TB162-10 550 50 3 207.00
TB162-11 440-480 60 4 207.00
TB162-12 24 60 3 207.00
TB162-13 277 60 3 207.00
TB162-14 200-208 60 3 207.00
TB162-14 110-120 25 3 207.00
TB162-15 380 50 3 207.00
TB162-15 220-240 25 3 248.00
TB162-16 200-208 60 4 248.00
TB162-16 110-120 25 4 248.00
TB162-17 380 50 4 248.00
TB162-17 220-240 25 4 248.00
TB162-19 110 60 4 248.00
Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 344L1 110-120 60 $53.00 For Use 335L1 110-120 60 $322.00
With Series: 344L1 110 50 53.00 With Series: 335L1 110 50 322.00
5000A*, 7000, 344L5 220-240 60 53.00 5000-*, 5DP5, 335L2 220-240 60 322.00
344L3 440-480 60 53.00 5DP8 335L2 220 50 322.00
7001, 8000B
344L3 440 50 53.00 335L3 440-480 60 322.00
(Size 00, 0, 1, (Size 5
344L4 550-600 60 53.00 335L3 440 50 322.00
10/40 Amp, 344L4 550 50 53.00
360,535 Amp) 335L4 550-600 60 322.00
40 Amp) 344L6 24 60 53.00 335L7 208 60 322.00
344L2 200-208 60 53.00
Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 343L1 110-120 60 $76.00 For Use 347L1 110-120 60 $1656.
With Series: 343L2 220-240 60 76.00 With Series: 347L4 220-240 60 2185.
5000A*,5DP7, 343L2 220 50 76.00 5DP6 347L2 440-480 60 2185.
8000B 343L3 440-480 60 76.00
700 Amp
343L3 440 50 76.00
(Size 2
343L4 550-600 60 76.00
75 Amp) 343L4 550 50 76.00
343L5 208 60 76.00 NOTE:
For further information on Power Pack Kits
(AC Coil) see page J6
Description Coil Volts Hertz Price Description Coil Volts Hertz Price
For Use 319L1 110-120 60 $110.00 For Use 320L1 110-120 60 $156.00
With Series:
5000A*,5DP1,
319L1
319L2
110
220-240
50
60
110.00
110.00
With Series:
5000-*,
320L1
320L2
110
220-240
50
60
156.00
156.00
N
319L3 440-480 60 110.00 5DP3-*, 320L3 440-480 60 156.00
5DP2, 8000B,
319L3 440 50 110.00 320L3 440 50 156.00
0 5DP3A* 5DP4, 5DP9,
2 319L4 550-600 60 110.00 320L4 550-600 60 156.00
6 (Size 3 319L4 550 50 110.00
8000B 320L4 550 50 156.00
30, 56, 319L5 24 60 110.00 (Size 4 110*, 320L2 200-208 60 156.00
110 * Amp) 319L2 200-208 60 110.00 180,260 Amp)
* NOTE:
Series 5DP3A 110 Amp., and 5DP3- 110 Amp., are not interchangeable
Series 5000A and 5000- are not interchangeable
AC Reversing Contactors
6031TM B6 Type TM General Purpose
6031VC
6031VC
A14
A31
USAVAC General Purpose
MV USAVAC General Purpose
N
6031HP C4 Type HP General Puropse
USAVAC A13 Mechanically Interlocked for Two Speed & 0
Reduced Voltage Applications 2
6
N6 Discount ScheduleM1
JC90
Alpha-Numerical Index of Catalog Number Prefixes
Prefix Page Prefix Page Prefix Page
M1
N7