0% found this document useful (0 votes)
71 views2 pages

Handy Thermo: MODEL NO.:ST-9262A/B/C

This document provides information on a handy thermo model with three functions: A) on/off, F/C, and H/T functions; B) on/off, F/C, and max/min memory recall; and C) on/off, H/T, and max/min memory recall. It has features like auto shut off, stainless steel probe, temperature unit selection, data hold, low battery indicator, and specifications on measurement range, resolution, accuracy, and battery. It describes operation instructions to take and hold temperature readings, and select units, as well as precautions for use.

Uploaded by

Nicolas Gilliot
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views2 pages

Handy Thermo: MODEL NO.:ST-9262A/B/C

This document provides information on a handy thermo model with three functions: A) on/off, F/C, and H/T functions; B) on/off, F/C, and max/min memory recall; and C) on/off, H/T, and max/min memory recall. It has features like auto shut off, stainless steel probe, temperature unit selection, data hold, low battery indicator, and specifications on measurement range, resolution, accuracy, and battery. It describes operation instructions to take and hold temperature readings, and select units, as well as precautions for use.

Uploaded by

Nicolas Gilliot
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MODEL NO.

:ST-9262A/B/C
Handy Thermo

FUNCTION:
A ON/OFF, °F/°C & H/T FUNCTION
B ON/OFF, °F/°C & MAX/MIN (°F/°C) MEMORY
RECALLING FUNCTION
C ON/OFF, H/T & MAX/MIN (°F/°C) MEMORY
RECALLING FUNCTION

FEATURES:
ONE HOUR AUTO SHUT OFF
133MM. STAINLESS STEEL SENSOR PROBE
MAX/MIN (°F/°C) MEMORY RECALLING
TEMPERATURE UNIT °F/°C SELECTABLE
DATA HOLD/TEST FUNCTION SELECTABLE
1 SEC. NORMAL TEMPERATURE SENSING
TIME
PROTECTIVE PLASTIC PROBE CAP FOR STAINLESS STEEL
LOW BATTERY INDICATOR

SPECIFICATION:
MEASUREMENT RANGE: []-50°C ~ +150°C OR -58°F ~ +302°F
[]-50°C ~ +300°C OR -58°F ~ +572°F
RESOLUTION :0.1° FOR -19.9° ~ +199.9°, OTHERWISE 1°
ACCURACY : []±1°C IN THE RANGE OF -30°C ~ +150°C
[]±1.8°F IN THE RANGE OF -22°F ~ +302°F
[]±1°C IN THE RANGE OF 151°C ~ +250°C, OTHERWISE MORE
THAN ± 2°C
[]±1.8°F IN THE RANGE OF 303.8°F ~ +482°F, OTHERWISE MORE
THAN ± 4°F
AMBIENT TEMPERATURE FOR PLASTIC CASING: -10°C ~ +50°C OR +14°F ~
+122°F
BATTERY : 1 X 1.5V "G13/A76" SIZE OR EQUIVALENT

OPERATION:
1. SLIDE THE "ON/OFF" SWITCH TO "ON" POSITION. ALL FUNCTIONS WILL SHOW
ON THE DISPLAY. THE THERMOMETER IS READY FOR USE.
[] SLIDE THE "°F/°C" SWITCH TO SELECT DESIRED TEMPERATURE UNIT. IT
WILL CHANGEIMMEDIATELY.
[] SLIDE "HOLD/TEST" SWITCH TO "TEST" POSITION FOR TEMPERATURE
MEASUREMENT OR "HOLD"POSITION TO RETAIN READING FOR RECORDING.
THE WORD "HOLD" WILL FLASH ON THE DISPLAY TOINDICATE THE HOLDING
POSITION.
[] PRESS THE "MAX / MIN" BUTTON, THE MINIMUM TEMPERATURE TESTED
WILL DISPLAY. "MIN" SIGN WILL BE SHOWN. PRESS THE BUTTON AGAIN
WITHIN THREE SECONDS FOR THE MAXIMUM TEMPERATURE TESTED. "MAX"
SIGN WILL BE SHOWN. IT WILL GO BACK TO THE TESTING POSITION
AUTOMATICALLY AFTER THREE SECONDS.
2. PRESS THE "ON/OFF" BUTTON. ALL FUNCTIONS WILL SHOW ON THE DISPLAY
FOR A SECOND AND THE THERMOMETER IS READY FOR USE.
[] PRESS THE "°F/°C" BUTTON TO SELECT DESIRED TEMPERATURE UNIT. IT
WILL CHANGE IMMEDIATELY.
[] PRESS THE "HOLD/TEST" BUTTON TO "TEST" POSITION FOR
TEMPERATURE MEASUREMENT OR "HOLD"POSITION TO RETAIN READING
FOR RECORDING. THE WORD "HOLD" WILL FLASH ON THE DISPLAY
TONDICATE THE HOLDING POSITION.
[] PRESS THE "MAX / MIN" BUTTON, THE MINIMUM TEMPERATURE TESTED
WILL DISPLAY. "MIN" SIGN WILL BE SHOWN. PRESS THE BUTTON AGAIN
WITHIN THREE SECONDS FOR THE MAXIMUM TEMPERATURE TESTED. "MAX"
SIGN WILL BE SHOWN. IT WILL GO BACK TO THE TESTING POSITION
AUTOMATICALLY AFTER THREE SECONDS.

PRECAUTIONS:
TO OBTAIN THE BEST RESULTS, THE PROBE TIP SHOULD BE IMMERSED AT
LEAST 10MM. INTO THE TESTED SUBSTANCE.
REMOVE THE BATTERY FROM THE BATTERY COMPARTMENT IF THE
THERMOMETER WILL NOT BE USED FOR LONG DURATION OF TIME OR
DURING STORAGE.
THE THERMOMETER CANNOT BE USED OR PUT INSIDE ANY OVEN OR
MICROWAVE.