SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Pipeline Right of Way (ROW) Inspection SAIC-L-1001 18-May-05 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

The pipeline route as stipulated on the Issued for Construction (IFC)


drawings shall be surveyed by the Construction Contractor. Changes to SAES-L-450
A1
original routing may be acceptable with prior approval by Saudi Aramco Sec. 7.1.1
PMT in the form of Modified IFC Drawings.

The Construction Contractor shall field verify the original vertical profile of
SAES-L-450
A2 the pipeline, the amount of cover, the location and degree of elastic and
Sec. 7.1.2
preformed bends, in accordance with the IFC drawings.

SAES-L-450
A3 Limits of the right of way shall be staked.
Sec. 7.1.1

Height or elevation of the right of way shall be staked and marked for SAES-L-450
A4
reference. Sec. 7.1.1

Construction waste materials shall be removed from the right-of-way as SAES-L-450


A5
the construction progresses. Sec. 19.1

Provisions shall be made to prevent wash-out of pipeline cover by rain SAES-L-450


A6
storms during construction operations. Sec. 7.1.4

The construction right of way shall be graded either flat or to a smooth SAES-L-450
A7
rolling contour. Sec. 7.2.1

In Sabkha areas, fill shall be provided to support construction equipment SAES-L-450


A8
as required. Sec. 7.2.2

The final finished right of way shall be at least 5 meters wide, 6 meters in SAES-L-450
A9
Sabkha areas. Sec. 7.2.3

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-L-450 -- Construction of On-Land and Near Shore Pipelines, 30 September 2003

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 1 of 1