Folheto Técnico Opcionais para Conversores

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

MAKING MODERN LIVING POSSIBLE

VLT® Drives FC Series


Option Overview
An overview of available options for
VLT® HVAC Drive, VLT® Refrigeration Drive, VLT® AQUA Drive and VLT®
AutomationDrive.

www.danfoss.com/drives
Slot A

VLT® PROFIBUS DP MCA 101


Operating the frequency converter via a field 
Fast, efficient communication, transpa-
bus enables you to reduce the cost of your sys- rent installation, advanced diagnosis and
tem, communicate faster and more efficiently, parameterisation and auto-configuration of
and benefit from an easier user interface. process data via GSD-file

A-cyclic parameterisation using

VLT® PROFIBUS DP MCA 101 provides wide PROFIBUS DP-V1, PROFIdrive or Danfoss
compatibility, a high level of availability, FC profile state machines, PROFIBUS DP-V1,
support for all major PLC vendors, and com- Master Class 1 and 2
patibility with future versions

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1100 uncoated
130B1200 coated ● ● ● ●

VLT® PROFINET MCA 120


VLT® PROFINET MCA 120 uniquely combines  Support of DP-V1 Diagnostic allows easy, fast
the highest performance with the highest and standardized handling of warning and
degree of openness. The MCA120 gives the user fault information into the PLC, improving
access to the power of Ethernet. The option is bandwidth in the system
designed so that many of the features from the
PROFIBUS MCA 101 can be reused, minimising PROFINET encompasses a suite of messages
user effort to migrate PROFINET, and securing and services for a variety of manufacturing
the investment in PLC program. automation applications, including control,
configuration and information.
Other features:
 Built-in web server for remote diagnosis and
reading out of basic drive parameters

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1135 uncoated
130B1235 coated ● ● ● ●

VLT® DeviceNet MCA 104


VLT® DeviceNet MCA 104 offers robust, efficient 
This modern communications model offers
data handling thanks to advanced Producer/ key capabilities that let you effectively deter-
Consumer technology. mine what information is needed and when

Benefit also from ODVA’s strong conform-
ance testing policies, which ensure that
products are interoperable

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1102 uncoated
130B1202 coated ● ● ● ●

VLT® DeviceNet Converter MCA 194 *


The VLT® DeviceNet Converter MCA 194 upgrade to a different fieldbus, the installed
emulates VLT® 5000 commands in the VLT® converter can easily be removed and replaced
AutomationDrive. This means that a VLT® 5000 with a different option. This secures the invest-
can be replaced by the VLT® AutomationDrive ment without losing flexibility. The option
or an existing system can be expanded, without emulates I/O instances & explicite messages of
costly change of the PLC program. For a later a VLT® 5000.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
NA uncoated
130B5601 coated ● ● ● ●

* Release in Q1, 2013

2
Slot A

VLT® EtherNet/IP MCA 121


Ethernet is the future standard for communica- The VLT® MCA 121 offers advanced features as:
tion at the factory floor. The VLT® EtherNet/IP Built-in high performance switch enabling
MCA 121 is based on the newest technology line-topology, and eliminating the need for
available for industrial use and handles even external switches
the most demanding requirements. EtherNet/ Advanced switch and diagnoses functions
IP extends commercial off-the-shelf Ethernet Built-in web server
to the Common Industrial Protocol (CIP™) – the E-mail client for service notification
same upper-layer protocol and object model  Unicast and Multicast communication
found in DeviceNet.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1119 uncoated
130B1219 coated ● ● ● ●

VLT® CANopen MCA 105


High flexibility and low cost are two of the For interoperability the option has
“cornerstones” for CANopen. The VLT® CANopen implemented the DSP402 AC drive Profile.
MCA 105 option for the AutomationDrive is This all guarantees standardised handling,
fully equipped with both high priority access to interoperability and low cost.
control and status of the Drive (PDO Commu-
nication) and access to all Parameters through
acyclic data (SDO Communication).

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1103 uncoated
130B1205 coated ● ●

VLT® EtherCAT MCA 124


The VLT® EtherCAT MCA 124 offers connectivity CoE CAN over EtherCAT Support
to EtherCAT based networks via the EtherCAT  EoE Ethernet over EtherCAT support
Protocol.  HTTP (Hypertext Transfer Protocol) for diag-
The option handles the EtherCAT line commu- nosis via built-in web server
nication in full speed, and connection towards  SMTP (Simple Mail Transfer Protocol) for e-
the drive of a Interval down to 4 ms in both di- mail notification
rections. This allows the MCA124 to participate  TCP/IP for easy access to Drive configuration
in networks from low performance up to servo data from MCT 10
applications.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B5546 uncoated
130B5646 coated ● ●

VLT® POWERLINK MCA 123


VLT® POWERLINK MCA 123 represents the nication models, network management and
second generation of fieldbus. The high bit rate device description model offers much more
of industrial ethernet can now be used to make than just a fast communication network.
the full power of IT technologies used in the au-
tomation world available for the factory world. The perfect solution for:
Dynamic motion control
POWERLINK does not only provide high per- applications
formance real-time and time synchronisation  Material handling
features. Due to its CANopen-based commu-  Synchronisation and positioning
applications

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1489 uncoated
130B1490 coated ● ●

3
Slot A

VLT® LonWorks MCA 108


LonWorks is a fieldbus system developed for 
Supports Echelon free-topology interface
building automation. It enables communication (flexible cabling and installation)
between individual units in the same system 
Supports embedded I/Os and I/O options
(peer-to-peer) and thus supports decentralising (easy implementation of de-central I/Os)
of control. 
Sensor signals can quickly be moved to
another controller via bus cables

No need for big main station 
Certified as compliant with LonMark ver. 3.4
(master-follower) specifications

Units receive signals directly

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1106 uncoated
130B1206 coated ●

VLT® BACnet MCA 109


The open communications protocol for world- 
With no license fees, the protocol can be
wide building automation. used in building automation systems of all
The BACnet protocol is an international proto- sizes
col that efficiently integrates all parts of build- 
The BACnet option lets the drive commu-
ing automation equipment from the actuator nicate with building management systems
level to the building management system. running the BACnet protocol

Typical areas where BACnet is used include

BACnet is the world standard for building heating, ventilation, cooling and climate
automation equipment control

International standard ISO 16484-5 
The BACnet protocol is easily integrated into
existing control equipment networks

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1144 uncoated
130B1244 coated ●

VLT® Modbus TCP MCA 122


Modbus TCP is the first industrial Ethernet Other features:
based protocol for automation. The VLT® Built-in web-server for remote diagnosis
Modbus TCP MCA 122 connects to Modbus TCP and reading out basic drive parameters
based networks. It is able to handle connec- An e-mail notificator can be configured
tion interval down to 5 ms in both directions, for sending an e-mail message to one or
positioning it among the fastest performing several receivers, if certain warnings or
Modbus TCP devices in the market. For master alarms occurs, or has cleared again
redundancy it features hot swapping between
two masters.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1196 uncoated
130B1296 coated ● ● ● ●

4
Slot A

VLT® PROFIBUS Converter MCA 113


The VLT® PROFIBUS Converter MCA 113 is a of the PLC program. For upgrade to a differ-
special version of the Profibus options that ent fieldbus, the installed converter is easily
emulates the VLT® 3000 commands in the VLT® removed and replaced with a new option.
AutomationDrive. The VLT® 3000 can then be This secures the investment without losing
replaced by the VLT® AutomationDrive, or the flexibility.
system can be expanded without costly change

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
NA uncoated
130B1245 coated ●

VLT® PROFIBUS Converter MCA 114


The VLT® PROFIBUS Converter MCA 114 is a of the PLC program. For upgrade to a differ-
special version of the Profibus options that ent fieldbus, the installed converter is easily
emulates the VLT® 5000 commands in the VLT® removed and replaced with a new option. This
AutomationDrive.The VLT® 5000 can then be secures the investment without losing flexibil-
replaced by the VLT® AutomationDrive, or the ity. The option supports DPV1.
system can be expanded without costly change

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
NA uncoated
130B1246 coated ●

VLT® LonWorks for ADAP-KOOL® MCA 107


ADAP-KOOL® is a complete electronic refrigera- this drive to ADAP-KOOL® Lon network is really
tion and control system for monitoring and simple. After entering a network address, press-
controlling refrigeration plants. Connecting ing a service pin starts the automatic configura-
tion procedure.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1169 uncoated
130B1269 coated ●

5
Slot B

VLT® General Purpose I/O MCB 101


This I/O option offers an extended number of 
2 analogue inputs 0-10 V: Resolution 10 bit
control inputs and outputs: plus sign

2 digital outputs NPN/PNP push pull

3 digital inputs 0-24 V: Logic ‘0’ < 5 V; 
1 analogue output 0/4-20 mA
Logic ‘1’ > 10V 
Spring loaded connection

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1125 uncoated
130B1212 coated ● ● ● ● ●

VLT® Encoder Input MCB 102


A universal option for connection of encoder Encoder module supports:
feedback from either a motor or a process.  Incremental encoders
Feedback for asynchronous or brushless servo  SinCos encoders as Hyperface®
(Permanent Magnet) motors. Power supply for encoders
RS422 interface
Connection to all standard 5 V incremental
encoders
Spring-loaded connection

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1115 uncoated
130B1203 coated ● ●

VLT® Resolver Input MCB 103


Supports resolver feedback for asynchronous or  Primary Voltage......................................2 – 8 Vrms
brushless servo (Permanent Magnet) motors. Primary Frequency....................2.0 kHz – 15 kHz
Primary current max............................50 mA rms
Secondary input voltage ...........................4 Vrms
Spring loaded connection

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1127 uncoated
130B1227 coated ● ●

VLT® Relay Option MCB 105


Makes it possible to extend relay functions with Min. terminal load:
3 additional relay outputs.  DC 5 V ............................................................... 10 mA
 Max switch rate at rated
Max. terminal load: load/min. load ............................. 6 min-1/20 sec-1
AC-1 Resistive load ......................... 240 V AC 2 A  Protects control cable connection
 AC-15 Inductive  Spring-loaded control wire connection
load @cos fi 0.4 ..............................240 V AC 0.2 A
 DC-1 Resistive load ........................... 24 V DC 1 A
 DC-13 Inductive
load @cos fi 0.4 ................................24 V DC 0.1 A

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1110 uncoated
130B1210 coated ● ● ● ● ●

6
Slot B

VLT® Safe PLC I/O MCB 108


The VLT® AutomationDrive FC 302 provides  The Safe PLC Interface allows the Safe PLC
a safety input based on a single pole 24 V DC to interrupt on the plus or the minus link
input. without interfering the sense signal of the
Safe PLC

For the majority of applications this input
enables the user to implement safety in a
cost-effective way. For application that works
with more advanced products like Safety
PLC, Lightcurtains etc. the Safe PLC interface
enables the connection of a two wire safety
link

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1120 uncoated
130B1220 coated ● ● ● ● ●

VLT® Analog I/O Option MCB 109


This analogue input/output option is easily fit-  3 analogue inputs, each configurable as both
ted in the frequency converter for upgrading to voltage and temperature input
advanced performance and control using the  Connection of 0-10 V analogue signals as
additional in/outputs.This option also upgrades well as PT1000 and NI1000 temperature
the frequency converter with a battery back-up inputs
supply for the frequency converter’s built-in  3 analogue outputs each configurable as
clock. This provides stable use of all frequency 0-10 V outputs
converter clock functions as timed actions etc.  Incl. back-up supply for the standard clock
function in the frequency converter

The back-up battery typically lasts for 10 years,


depending on environment.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1143 uncoated
130B1243 coated ● ● ●

VLT® PTC Thermistor Card MCB 112


With the VLT® PTC Thermistor Card MCB 112,  Protects the motor from overheating
the VLT® AutomationDrive FC 302 enables  ATEX approved for use with Ex d and Ex e
improved surveillance of the motor condition motors (EX e only FC302)
compared to the built-in ETR function and  Uses Safe Stop function, which is approved
thermistor terminal. in accordance with SIL 2 IEC 61508

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
NA uncoated
130B1137 coated ● ● ●

7
Slot B

VLT® Sensor Input Card MCB 114


The option protects the motor from being Protects the motor from overheating
overheated by monitoring the bearings and  Three self-detecting sensor inputs for 2 or 3
windings temperature in the motor. Both limits wire PT100/PT1000 sensors
as well action are adjustable, and the individual  One additional analogue input 4-20mA
sensor temperature is visible as a read-out on
the display or by fieldbus.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1172 uncoated
130B1272 coated ● ● ● ●

VLT® Safe Option MCB 140 Series


VLT® Safe Option MCB 140 Series are safety op- Different operating modes can be easily con-
tions providing Safe Stop 1 (SS1), Safely Limited figured by using the on board display and but-
Speed (SLS) and Safe Speed Monitor (SSM) tons. The options provide only a limited set of
functionallity. The options can be used up to PL parameters for easy and fast parameterization.
e according to ISO 13849-1.
 MCB140 standard B-Option
MCB140 is a standard B-Option while MCB141  MCB141 external Option
offers the same functionallity in an external  Single channel or dual channel operation
45 mm housing. MCB141 enables the user to possible
use the MCB140 functionallity also if another  Proximity switch as speed feedback
B-Option is used.  SS1, SLS and SMS functionallity
 Easy and fast parameterization

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B6443 MCB 140
130B6447 MCB 141 ● ● ● ● ●

VLT® Safe Option MCB 150 Series


The VLT® Safe Option MCB 150 Series expands  Additional standards-compliant safety func-
the Safe Torque Off STO function, which is tions
integrated in a standard VLT® AutomationDrive.  Replacement of external safety equipment
By using the Safe Stop 1 function it is possible Reduced space requirements
to perform a controlled stop before removing  2 safe programmable inputs
torque. Using the Safely Limited Speed SLS  1 safe output (for T37)
function it is also able to monitor whether a  Easier machine certification
specified speed is exceeded. The functions can  Drive can be powered continuously
be used up to PL d according to EN ISO 13849  Safe LCP Copy
and SIL 2 according to IEC 61508.  Dynamic commissioning report

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B3280 MCB 150
130B3290 MCB 151 ●

VLT® Extended Cascade Controller MCO 101


Easily fitted and upgrades the built-in cascade  Up to 6 pumps in standard cascade setup
controller to operate more pumps and more  Up to 5 pumps in master/follower setup
advanced pump control in master/follower  Technical specifications: See MCB 105 Relay
mode. Option

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1118 uncoated
130B1218 coated ●

8
Slot C

VLT® Advanced Cascade Controller MCO 102


Easy to fit, the VLT® Advanced Cascade Control- The same cascade controller hardware goes for
ler MCO 102 upgrades the built-in cascade for the entire power range up to 1.2 MW.
controller to operate up to 8 pumps and more  Up to 8 pumps in standard cascade setup
advanced pump control in master/follower  Up to 8 pumps in master/follower setup
mode.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1154 uncoated
130B1254 coated ●

VLT® Motion Control MCO 305


An integrated programmable motion controller Synchronisation (electronic shaft), position-
for VLT® AutomationDrive FC 301 and FC 302. ing and electronic cam control
The option adds fuctionality and flexibility  2 inputs supporting both incremental and
to the already very comprehensive standard absolute encoders
functionality of these drives. 1 encoder output (virtual master function)
10 digital inputs
VLT® Motion Control MCO 305 is optimised 8 digital outputs
for all types of positioning and synchronising  Send and receive data via fieldbus interface
applications. (requires fieldbus option)
PC software tools for programming and
commissioning

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1134 uncoated
130B1234 coated ● ●

VLT® Extended Relay Card MCB 113


The VLT® Extended Relay Card MCB 113 adds  7 digital inputs
inputs/outputs to VLT® AutomationDrive for  2 analogue outputs
increased flexibility.  4 SPDT relays
 Meets NAMUR recommendations
 Galvanic isolation capability

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1164 uncoated
130B1264 coated ● ●

9
Slot C

VLT® Synchronizing Controller MCO 350


The VLT® Synchronizing Controller MCO 350 for  Displays actual synchronising error on fre-
VLT® AutomationDrive expands the functional quency converter control panel
properties of the converter in synchronising  Speed synchronising
applications, and replaces traditional mechani-  Position (angle) synchronising with or with-
cal solutions. out marker correction
On-line adjustable gear ratio
On-line adjustable position (angle) offset
 Encoder output with virtual master function
for synchronisation of multiple followers
Homing

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1152 uncoated
130B1252 coated ● ●

VLT® Position Controller MCO 351


The VLT® Position Controller MCO 351 offers a  Direct positioning via Fieldbus
host of user-friendly benefits for positioning  Relative positioning
applications in many industries. They are based  Absolute positioning
on a range of thought-through and innovative  Touch probe positioning
features.  End limit handling (software and hardware)
Mechanical brake handling (programmable
hold delay)
 Error handling
 Jog speed/manual operation
 Marker related positioning
 Home function

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1153 uncoated
130B1253 coated ● ●

10
Slot D

VLT® 24 V DC Supply MCB 107


The option is used to connect an external DC 
Input voltage
supply to keep the control section and any range ....24 V DC +/- 15% (max. 37 V in 10 sec.)
installed option alive during power failure. 
Max. input current ......................................... 2.2 A

Max. cable length ........................................... 75 m

Input capitance load .................................< 10 uF

Power-up delay .............................................< 0.6 s

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1108 uncoated
130B1208 coated ● ● ● ● ●

11
LCP

VLT® Control Panel LCP 102


 Multi-language display  Alarm logging
 Status messages  Info button – explains the function of
 Quick menu for easy commissioning the selected item on display
Parameter setting and explanation of  Hand-operated start/stop, or Automatic
parameter function mode selection
 Adjusting of parameters  Reset function
 Full parameter backup and copy function  Trend graph

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1107 ● ● ● ● ●

VLT® Control Panel LCP 101


The numerical control panel offers 
Parameter setting and adjusting
an excellent MMI interface to the drive. 
Hand-operated start/stop function or
Automatic mode select

Status messages 
Reset function

Quick menu for easy commissioning

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1124 ● ● ● ●

LCP Panel Mounting Kit


All ordering numbers are for IP55/66 and
include fasteners and a gasket.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1113 With
fasteners, gasket,
graphical LCP and 3 ● ● ● ● ●
m cable
130B1114 With
fasteners, gasket,
numerical LCP and ● ● ● ●
3 m cable
130B1117 With
fasteners, gasket
and without LCP ● ● ● ● ●
and with 3 m cable
130B1129 With
fasteners, gasket,
blind cover and ● ● ● ● ●
8 m “free end” cable
130B1170 With
fasteners, gasket
and without LCP ● ● ● ● ●
and with 3 m cable

12
Power Options

VLT® Brake Resistor MCE 101


Energy generated during braking is absorbed  Enclosure protection as IP20 and up to IP65
by the resistors, protecting electrical compo-  Build-in thermo switch
nents from heating up. Danfoss brake resistors  Versions for vertical and horizontal mounting
are optimized for the FC-series and general  UL-recognized – only types for vertical
versions for horizontal and vertical applications mounting
are available.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
See relevant
Design Guide ● ● ● ● ●

VLT® Advanced Harmonic Filter AHF 005/010


Easy, effective harmonic distortion reduction by 
Small compact housing that fits into a panel
connecting the AHF 005/010 harmonic filter in 
Easy to use in retrofit applications
front of a Danfoss frequency converter. 
User-friendly start-up – no adjustment
necessary

AHF 005 reduces total harmonic current 
No routine maintenance required
distortion to 5% 
VLT® FC family look

AHF 010 reduces total harmonic current
distortion to 10%

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
See relevant
Design Guide ● ● ● ● ●

VLT® Sine-Wave Filters MCC 101


Sine-wave filters are placed between the 
Reduce motor insulation stress
frequency converter and the motor to optimise 
Reduce acoustic noise from the motor
the motor power current. It provides a sinusoi- 
Reduce bearing currents (especially in large
dal phase-to-phase motor voltage. The filters motors)
reduce motor insulation stress, acoustic noise 
Reduce losses in the motor
from the motor, and bearing currents (espe- 
Prolongs service lifetime
cially in large motors). 
VLT® FC family look

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
See relevant
Design Guide ● ● ● ● ●

VLT® dU/dt filter MCC 102


VLT® dU/dt filters are placed between the 
These filters reduce stress on the motor’s
frequency converter and the motor to eliminate insulation and are recommended in applica-
very fast voltage changes. The motor terminal tions with older motors, aggressive environ-
phase-to-phase voltage is still pulse shaped but ments or frequent braking which cause
its dU/dt values are reduced. increased DC link voltage.

VLT® FC family look

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
See relevant
Design Guide ● ● ● ● ●

13
Accessories

For use with option A


Profibus SUB-D9 Adapter
In some industries, the use of SUB-D9 connec- throughout all installed devices. Use of SUB-D9
tors is used as standard. The Profibus SUB-d9 cabling allow easy access for diagnose tools
Adapter allows the use of this connectors and programming devices.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1112 ● ●* ● ● ●
* Expected release in Q3, 2013

Adapter Plate for VLT® 3000 and VLT® 5000


For installations, where VLT3000 or VLT5000 to be drilled, with risk of getting shavings into
has to exchanged with the new FC series, electronic. In some cases even two FC’s can be
the Adapter plates are a perfect solution. mounted, where there in the past was only one
They has the same physical mounting as the VLT mounted.
VLT3/5000, which mean that no new holes has

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B0524
To be used only for
IP 20/NEMA type 1 ● ● ● ●
units up to 7.5 kW

VLT® B in C Option Adapter MCF 106


The B in C Option Adapter can be placed in VLT® Relay Card MCB 105 and VLT® PTC Thermis-
the Option C slot and allows for combination tor Card MCB 112 are not supported by the
of two different B options - either by placing adapter and must thus only be installed in the
both in the MCF 106 or by placing one in the standard slot B of the Control Card.
standard slot B of the Control Card and one in
the MCF 106.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1130 uncoated
130B1230 coated ● ● ● ●

VLT® Common Mode Filters


Common mode fi lters are placed between
the frequency converter and the motor.  Can be combined with du/dt and
They are nano-crystalline cores that mitigate sine-wave fi lters
high frequency noise in the motor  Reduce radiated emissions from the motor
cable (shielded or unshielded) and reduce cable
bearing currents in the motor.  Easy to install – no adjustments necessary
 Extend motor bearing lifetime  Oval shaped – allows mounting inside
the frequency converter enclosure or
motor terminal box
 No maintenance required

Ordering Frame VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
number size FC 102 FC 103 FC 202 FC 301 FC 302
130B3257 A and B
130B3258 C
130B3259 D ● ● ● ● ●
130B3260 E and F

14
USB extension
USB extension for IP 55 and IP 66 enclosures. USB extension for A5-B1 enclosures,
Makes the USB connector available outside 350 mm cable .............................................. 130B1155
the drive. The USB extension is designed for USB extension for B2-C enclosures,
mounting in a cable gland in the bottom of the 650 mm cable .............................................. 130B1156
drive, which makes PC communication very
easy even in drives with high IP rating.

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1155
350 mm cable ● ● ● ● ●
130B1156
650 mm cable ● ● ● ● ●

IP 21/Type 1 (NEMA1) Kit


The IP 21/Type 1 (NEMA1) kit is used for installa-  Supports VLT® drives from 1.1 to 90 (NO) kW
tion of VLT® drives in dry environments. The Used on standard VLT® drive with or without
enclosure kits are available for frame sizes A1, mounted option modules
A2, A3, B3, B4, C3 and C4 IP 41 on top side
PG 16 and PG 21 holes for glands

VLT® HVAC Drive VLT® Refrigeration Drive VLT® AQUA Drive VLT® AutomationDrive
Ordering number
FC 102 FC 103 FC 202 FC 301 FC 302
130B1121
For frame size A1 ● ●
130B1122
For frame size A2 ● ● ● ● ●
130B1123
For frame size A3 ● ● ● ● ●
130B1187
For frame size B3 ● ● ● ● ●
130B1189
For frame size B4 ● ● ● ● ●
130B1191
For frame size C3 ● ● ● ● ●
130B1193
For frame size C4 ● ● ● ● ●

15
What VLT® is all about
Danfoss VLT Drives is the world leader among dedicated drives providers
– and still gaining market share.

Environmentally Dedicated to drives Rely on the experts


Dedication has been a key word since We take responsibility for every
responsible 1968, when Danfoss introduced the element of our products. The fact that
VLT® products are manufactured
world’s first mass produced variable we develop and produce our own
with respect for the safety and
speed drive for AC motors – and features, hardware, software, power
well-being of people and the
named it VLT®. modules, printed circuit boards, and
environment.
accessories is your guarantee of
Twenty five hundred employees reliable products.
All frequency converter factories
develop, manufacture, sell and service
are certified according to ISO
drives and soft starters in more than Local backup – globally
14001 and ISO 9001 standards.
one hundred countries, focused only VLT® motor controllers are operating
on drives and soft starters. in applications all over the world and
All activities are planned and
Danfoss VLT Drives’ experts located in
performed taking into account
Intelligent and innovative more than 100 countries are ready to
the individual employee, the work
Developers at Danfoss VLT Drives support our customers with applica-
environment and the external en-
have fully adopted modular principles tion advice and service wherever they
vironment. Production takes place
in development as well as design, pro- may be.
with a minimum of noise, smoke or
duction and configuration.
other pollution and environmen-
tally safe disposal of the products is Danfoss VLT Drives experts don’t stop
Tomorrow’s features are developed in until the customer’s drive challenges
pre-prepared.
parallel using dedicated technology are solved.
platforms. This allows the develop-
UN Global Compact
ment of all elements to take place in
Danfoss has signed the UN Global
parallel, at the same time reducing
Compact on social and environ-
time to market and ensuring that
mental responsibility and our
customers always enjoy the benefits
companies act responsibly towards
of the latest features.
local societies.

Impact on energy savings


One year’s energy savings from our
annual production of VLT® drives
will save the energy equivalent
to the energy production from a
major power plant. Better process
control at the same time improves
product quality and reduces waste
and wear on equipment.

Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80,
www.danfoss.com/drives • E-mail: [email protected]

DKDD.PB.400.A2.02 VLT® is a trademark of Danfoss A/S Updated by PE-MMSC 2013.01

You might also like