Design of Isolated Footing (Calculation Sheet) EGYPTION CODE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F1

INPUT DATA:
fcu (footing)= 250.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible
1.00 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
30 cm
dimention)
c2 (column
30 cm
dimention)
Pw
40 tons
Working load
Pu
60 tons
Ultimate load

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 4.32 m²

PC AxBxT= 2.10 2.10 0.35 m


RC axbxH= 1.40 1.40 0.55 m

2- Factored load and soil reaction

qs=Pu/(axb) = 30.61 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 1.84 t/m²

w= 0.30 m

Tributary area = 0.42 m²

qcu = 6.53 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 40.408 ton


qup = Qup / bod = 2.53 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.640 m²

Qcup1 12.90 kg/cm²

Qcup2 26.94 kg/cm²


16 kg/m²
Qcup3 19.35 kg/cm²
Qcup 12.90 kg/cm² ok
a 4.00
bo 3.20 m

1/2

Concrete Design Program (C.D.P)


3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 4.63 m.t /m'

As 8.33 cm²

As_ total = 11.67 cm²

Area steel due to short direction

As _total = 11.67 cm²

Spacing
Use As (short direction) 11 F 12 14 cm
Use As (long direction) 11 F 12 14 cm

4- bearing Strength of column

0.67A1fcu/c 120.600 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/c 201.000 ton > Pu ok

2/2

Concrete Design Program (C.D.P)


Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F2

INPUT DATA:
fcu (footing)= 250.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible
1.00 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
30 cm
dimention)
c2 (column
40 cm
dimention)
Pw
50 tons
Working load
Pu
75 tons
Ultimate load

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 5.40 m²

PC AxBxT= 2.40 2.30 0.35 m


RC axbxH= 1.70 1.60 0.55 m

2- Factored load and soil reaction

qs=Pu/(axb) = 27.57 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 2.21 t/m²

w= 0.40 m

Tributary area = 0.68 m²

qcu = 6.53 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 55.147 ton


qup = Qup / bod = 3.24 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.720 m²

Qcup1 12.90 kg/cm²

Qcup2 25.74 kg/cm²


16 kg/m²
Qcup3 16.13 kg/cm²
Qcup 12.90 kg/cm² ok
a 4.00
bo 3.40 m

1/2

Concrete Design Program (C.D.P)


3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 5.82 m.t /m'

As 8.33 cm²

As_ total = 14.17 cm²

Area steel due to short direction

As _total = 13.33 cm²

Spacing
Use As (short direction) 13 F 12 14 cm
Use As (long direction) 12 F 12 14 cm

4- bearing Strength of column

0.67A1fcu/c 160.800 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/c 268.000 ton > Pu ok

2/2

Concrete Design Program (C.D.P)


Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F3

INPUT DATA:
fcu (footing)= 250.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible
1.00 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
40 cm
dimention)
c2 (column
40 cm
dimention)
Pw
80 tons
Working load
Pu
120 tons
Ultimate load

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 8.64 m²

PC AxBxT= 2.95 2.95 0.35 m


RC axbxH= 2.25 2.25 0.55 m

2- Factored load and soil reaction

qs=Pu/(axb) = 23.70 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 3.20 t/m²

w= 0.68 m

Tributary area = 1.52 m²

qcu = 6.53 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 100.800 ton


qup = Qup / bod = 5.60 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.810 m²

Qcup1 12.90 kg/cm²

Qcup2 24.68 kg/cm²


16 kg/m²
Qcup3 19.35 kg/cm²
Qcup 12.90 kg/cm² ok
a 4.00
bo 3.60 m

1/2

Concrete Design Program (C.D.P)


3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 10.14 m.t /m'

As 8.33 cm²

As_ total = 18.75 cm²

Area steel due to short direction

As _total = 18.75 cm²

Spacing
Use As (short direction) 17 F 12 14 cm
Use As (long direction) 17 F 12 14 cm

4- bearing Strength of column

0.67A1fcu/c 214.400 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/c 357.333 ton > Pu ok

2/2

Concrete Design Program (C.D.P)


Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F4

INPUT DATA:
fcu (footing)= 250.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible
1.00 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
30 cm
dimention)
c2 (column
50 cm
dimention)
Pw
80 tons
Working load
Pu
120 tons
Ultimate load

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 8.64 m²

PC AxBxT= 3.05 2.85 0.35 m


RC axbxH= 2.35 2.15 0.55 m

2- Factored load and soil reaction

qs=Pu/(axb) = 23.75 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 3.21 t/m²

w= 0.68 m

Tributary area = 1.59 m²

qcu = 6.53 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 101.000 ton


qup = Qup / bod = 5.61 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.800 m²

Qcup1 12.90 kg/cm²

Qcup2 24.68 kg/cm²


16 kg/m²
Qcup3 14.19 kg/cm²
Qcup 12.90 kg/cm² ok
a 4.00
bo 3.60 m

1/2

Concrete Design Program (C.D.P)


3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 10.16 m.t /m'

As 8.33 cm²

As_ total = 19.58 cm²

Area steel due to short direction

As _total = 17.92 cm²

Spacing
Use As (short direction) 18 F 12 13 cm
Use As (long direction) 16 F 12 14 cm

4- bearing Strength of column

0.67A1fcu/c 201.000 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/c 335.000 ton > Pu ok

2/2

Concrete Design Program (C.D.P)


Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F5

INPUT DATA:
fcu (footing)= 250.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible
1.00 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
30 cm
dimention)
c2 (column
40 cm
dimention)
Pw
80 tons
Working load
Pu
120 tons
Ultimate load

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 8.64 m²

PC AxBxT= 3.00 2.90 0.35 m


RC axbxH= 2.30 2.20 0.55 m

2- Factored load and soil reaction

qs=Pu/(axb) = 23.72 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 3.32 t/m²

w= 0.70 m

Tributary area = 1.61 m²

qcu = 6.53 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 102.925 ton


qup = Qup / bod = 6.05 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.720 m²

Qcup1 12.90 kg/cm²

Qcup2 25.74 kg/cm²


16 kg/m²
Qcup3 16.13 kg/cm²
Qcup 12.90 kg/cm² ok
a 4.00
bo 3.40 m

1/2

Concrete Design Program (C.D.P)


3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 10.70 m.t /m'

As 8.33 cm²

As_ total = 19.17 cm²

Area steel due to short direction

As _total = 18.33 cm²

Spacing
Use As (short direction) 17 F 12 14 cm
Use As (long direction) 17 F 12 13 cm

4- bearing Strength of column

0.67A1fcu/c 160.800 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/c 268.000 ton > Pu ok

2/2

Concrete Design Program (C.D.P)


Design of Combiend Footing (Calculation Sheet) EGYPTION CODE

INPUT DATA: F6
fcu (footing)= 250 kg/cm²
fy = 3600 kg/cm²
Net permissible
1 kg/cm²
soil presure
Footing cover 0.05 m.
Columns spaced 4.5 m.
Pu_1 90 tons
Pw_1 60 tons
Mux_1 = 0 m.t
Mwx_1= 0 m.t
Muy_1 = 0 m.t
Mwy_1 = 0 m.t
Pu_2 75 tons
Pw_2 50 tons
Mux_2 = 0 m.t
Mwx_2= 0 m.t
Muy_2 = 0 m.t
Mwy_2 = 0 m.t
a1 .4 m.
b1 .3 m.
a2 .3 m.
b2 .3 m.

1-Detemination of footing area

RC A x B x T = 5.25 2.50 0.60 m


PC a x b x H = 5.65 3.30 0.35 m
ow ( footing RC ) 19.69 ton
Pw1=Pw+Pw_2+ ow 129.69 ton Total Moment on columns c1 and c2
Pu=Pu_1+Pu_2 165.00 ton
Mwx = Mwx_1+Mwx_2 0.00 m.t
Mwy = Mwy_1+Mwy_2 0.00 m.t
Mux = Mux_1+Mux_2 0.00 m.t
Muy = Muy_1+Muy_2 0.00 m.t

2- Check of stresse on soil

f(w) = ( Rw / Af )+ ( Mwx * y / Ixx )+ ( Mwy * x / Iyy )

X= 2.050 m
Ixx = 6.840 m⁴
Iyy = 30.150 m⁴
x= 2.620 m.
y= 1.250 m.
f (1) = 9.880 t/m²
f (2) = 9.880 t/m²
f (3) = 9.880 t/m²
f (4) = 9.880 t/m²
Ok

1/3

Concrete Design Program(C.D.P)


3- Check of overturning

Fs (Factor of safty with-X) No Need Ok > 2.00

Fs (Factor of safty with-y) No Need Ok > 2.00

4- Check of Shear

f(u) = ( Ru / Af )+ ( Mux * y / Ixx )+ ( Muy * x / Iyy )


qu = Muximum stress (1,2,3,4) 12.570 t/m²
qu= qumax*b = 31.430 t/m
Q1 = 3.930 ton
Q2 = 56.960 ton
Q3 = 56.180 ton
Q4 = 0.000 ton
qu =Qumax /b*d 4.140 kg/cm²

6.530 kg/cm²

5- Check of punching

for column1
Reaction at column 1 = 90.750 ton
bo1 = 3.600 m.
qup1 4.580 kg/cm²
s1 = 4.000
qcup1 = 12.900 kg/cm²
for column2 16 kg/m²
Reaction at column 2 = 74.250 ton
bo2 = 2.000 m.
qup2 6.750 kg/cm²
s2 = 4.000
qcup2 = 12.900 kg/cm²

6- Design of section due to moment

Moment due to x - direction


Mux1 = 5.66 m.t
Mux2 = -76.57 m.t
Mux3 = 0.35 m.t

As_x1 = 22.920 cm²


As_x2 = 46.700 cm²
As_x3 = 22.920 cm²

Area steel due to y - direction


q1=pu1/b = 36.300 t/m
Muy4 = 21.960 m.t
q2=pu2/b = 29.700 t/m
Muy5 = 17.970 m.t

w1 0.950 m.
w2 0.570 m.
As_y4 (w1) = 13.220 cm²
As_y5 (w2) = 10.970 cm²

2/3

Concrete Design Program(C.D.P)


7- Reinforcement summary
Spacing
Use As1 ( x- direction ) 21 F 12 12 cm
Use As2 (x- direction) 24 F 16 10 cm
Use As3 ( x- direction ) 21 F 12 12 cm

Range
Use As4 (y- direction) 7 F 16 15 cm 0.950
Use As5 ( y- direction ) 6 F 16 11 cm 0.570

8-Footing Dimension

PC A x B x T = 5.25 2.50 0.40 m.


RC a x b x H = 5.65 3.30 0.60 m.

9-Details

( X ) Destance from center of big column load to center of footing =

(X)= 2.050 m.

3/3

Concrete Design Program(C.D.P)


Design of Combiend Footing (Calculation Sheet) EGYPTION CODE

INPUT DATA: F7
fcu (footing)= 250 kg/cm²
fy = 3600 kg/cm²
Net permissible
1 kg/cm²
soil presure
Footing cover 0.05 m.
Columns spaced 4.5 m.
Pu_1 150 tons
Pw_1 100 tons
Mux_1 = 0 m.t
Mwx_1= 0 m.t
Muy_1 = 0 m.t
Mwy_1 = 0 m.t
Pu_2 97.5 tons
Pw_2 65 tons
Mux_2 = 0 m.t
Mwx_2= 0 m.t
Muy_2 = 0 m.t
Mwy_2 = 0 m.t
a1 .4 m.
b1 .6 m.
a2 .4 m.
b2 .4 m.

1-Detemination of footing area

RC A x B x T = 5.90 3.30 0.60 m


PC a x b x H = 6.30 4.10 0.35 m
ow ( footing RC ) 29.20 ton
Pw1=Pw+Pw_2+ ow 194.20 ton Total Moment on columns c1 and c2
Pu=Pu_1+Pu_2 247.50 ton
Mwx = Mwx_1+Mwx_2 0.00 m.t
Mwy = Mwy_1+Mwy_2 0.00 m.t
Mux = Mux_1+Mux_2 0.00 m.t
Muy = Muy_1+Muy_2 0.00 m.t

2- Check of stresse on soil

f(w) = ( Rw / Af )+ ( Mwx * y / Ixx )+ ( Mwy * x / Iyy )

X= 1.770 m
Ixx = 17.670 m⁴
Iyy = 56.480 m⁴
x= 2.950 m.
y= 1.650 m.
f (1) = 9.970 t/m²
f (2) = 9.970 t/m²
f (3) = 9.970 t/m²
f (4) = 9.970 t/m²
Ok

1/3

Concrete Design Program(C.D.P)


3- Check of overturning

Fs (Factor of safty with-X) No Need Ok > 2.00

Fs (Factor of safty with-y) No Need Ok > 2.00

4- Check of Shear

f(u) = ( Ru / Af )+ ( Mux * y / Ixx )+ ( Muy * x / Iyy )


qu = Muximum stress (1,2,3,4) 12.710 t/m²
qu= qumax*b = 41.950 t/m
Q1 = 30.410 ton
Q2 = 80.990 ton
Q3 = 67.930 ton
Q4 = 0.000 ton
qu =Qumax /b*d 4.460 kg/cm²

6.530 kg/cm²

5- Check of punching

for column1
Reaction at column 1 = 151.250 ton
bo1 = 4.200 m.
qup1 6.550 kg/cm²
s1 = 4.000
qcup1 = 12.900 kg/cm²
for column2 16 kg/m²
Reaction at column 2 = 96.250 ton
bo2 = 2.300 m.
qup2 7.610 kg/cm²
s2 = 4.000
qcup2 = 12.900 kg/cm²

6- Design of section due to moment

Moment due to x - direction


Mux1 = 30.20 m.t
Mux2 = -91.17 m.t
Mux3 = 0.84 m.t

As_x1 = 30.250 cm²


As_x2 = 55.320 cm²
As_x3 = 30.250 cm²

Area steel due to y - direction


q1=pu1/b = 45.830 t/m
Muy4 = 41.770 m.t
q2=pu2/b = 29.170 t/m
Muy5 = 30.660 m.t

w1 0.950 m.
w2 0.680 m.
As_y4 (w1) = 26.080 cm²
As_y5 (w2) = 19.200 cm²

2/3

Concrete Design Program(C.D.P)


7- Reinforcement summary
Spacing
Use As1 ( x- direction ) 27 F 12 12 cm
Use As2 (x- direction) 28 F 16 12 cm
Use As3 ( x- direction ) 27 F 12 12 cm

Range
Use As4 (y- direction) 13 F 16 7 cm 0.950
Use As5 ( y- direction ) 10 F 16 7 cm 0.680

8-Footing Dimension

PC A x B x T = 5.90 3.30 0.40 m.


RC a x b x H = 6.30 4.10 0.60 m.

9-Details

( X ) Destance from center of big column load to center of footing =

(X)= 1.770 m.

3/3

Concrete Design Program(C.D.P)


Design of Strap Footing (Calculation Sheet) EGYPTION CODE

INPUT DATA:
fcu = 250 kg/cm²
fy = 3600 kg/cm²
Net permissible
1 kg/cm²
soil presure
Pw1 50 tons
Pu1 75 tons
Pw2 80 tons
Pu2 120 tons
ac1 .3 cm
bc1 .4 cm
ac2 .4 cm
bc2 .4 cm
S 5 m.
Cover 0.05 cm
Strap width 0.40 cm
hf (Footing) 0.55 cm
hs (Strap) 1 cm

1-Determine footing dimensions


Assume e = 1.23 m.
S1 = 3.77 s1
Rw1 = 1.1*(Pw1)*S / S1 72.94 ton
Rw2 = 1.1*(Pw1 + Pw2) - R1 70.06 ton
Footing (1) Dimensions
A1 =2 * ( a1/2 + e ) 2.80 m.
B1 = R1 / ( qsoil * A1 ) 2.65 m.
a1 = 2.45 m.
b1 = 1.95 m.
Footing (2) Dimensions
A2 = 2.65 m.
B2 = R2 / qsoil * A2 2.65 m.
a2 = 1.95 m.
b2 = 1.95 m.

2- Flexure Design for Footings


S 1 = S + aco1 / 2 - a1 = 3.93 m.
Ru1 = Pu1*S / (S1) = 95.06 ton
Ru2 = Pu1+ Pu2 - Ru1 = 99.94 ton

Footings Design
Footing (1)
qu1 = Ru1 / (a1*b1) 20.30 t/m²
Mf1 = qs*( b1/2 - bco1/2 )² /2 6.04 m.t
df 1 = 0.50 cm²
As 1 = 8.33 cm² / m'

1/3

Concrete Design Program (C.D.P)


Footing (2)

qu2 = Ru2 / (a2*b2) 26.37 t/m²


Mf2 = qs*( b2/2 - bco2/2 )² /2 7.89 m.t
df 2 = 0.50 cm²
Asf 2 = 8.33 cm² / m'

3 -Wide beam action (Shear)

Footing (1)

tributary area = w x A1 1.28 m²


qu1 = qs1 x tributary area /A1*df1 2.12 kg/cm²
qcu = 6.53 kg/cm² Ok

Footing (2)

tributary area = w x A2 1.02 m²


qu2 = qs2 x tributary area /A2*df2 2.76 kg/cm²
qcu = 6.53 kg/cm² Ok

5 - Strap beam straining action


Streses
qu1 = Ru1 / ( A1 ) 39.44 t/m
qu2 = Ru2 / ( A2 ) 51.34 t/m

Shear forces
Q1 5.92 ton
Q2 -69.08 ton
Q3 20.06 ton
Q4 70.03 ton
Q5 -49.97 ton
Q22 -63.17 ton
Q44 59.76 ton
Q55 -39.70 ton

Moment values

M1 0.44 m.t
M2 -19.27 m.t
M3 24.32 m.t
Mmax -60.06 m.t
M3L 11.34 m.t
M3R 15.35 m.t

6 - Flexure Deaign of Strap beam.


For Mmax
ds = 0.95 m.
bs = 0.40 m.
As 1 = 21.98 cm²
For M3L or M3R

As 1 = 11.88 cm²
2/3

Concrete Design Program (C.D.P)


7 - Shear Deaign of Strap beam.

Design for Q3 Critial section at free span of strap beam

qu =Qu / b.d 5.28 kg/cm²

qcu = 9.80 kg/cm²

qumax = 28.58 kg/cm² And less than 40 kg/cm²

qsu = qu - 1/2 qcu 0.38 kg/cm²

Ast / b.s = qsu /(fy /γs)


Ast = 1.57 cm²

S= 129.68 cm
µmin1 = 0.40/fy = Ast/(b.S)
Smax1 = 35.34 cm
Smax2 =0.15 or 0.1 % * µ 39.27 cm
Smax3 = 20 cm 20.00 cm

Smax= 20.00 cm

8 - Details

Footing (1)

Dimensions A1 (m.) B1(m.) hf1 (m.)


PC 2.80 2.65 0.35
RC 2.45 1.95 0.55

As1 8 F 12

Footing (2)

Dimensions A2 (m.) B2 (m.) hf2 (m.)


2.65 2.65 0.35
RC 1.95 1.95 0.55

As2 8 F 12

Strap Beam

Dimensions bs (m.) hs (m.)


0.40 1.00

As3 11 F 16
As4 6 F 16
Stirrup reinforcement

Rinforcement /m' Branch number


As5 5 10 \m. 2

3/3

Concrete Design Program (C.D.P)


Design of Strap Footing (Calculation Sheet) EGYPTION CODE

INPUT DATA:
fcu = 250 kg/cm²
fy = 3600 kg/cm²
Net permissible
1 kg/cm²
soil presure
Pw1 80 tons
Pu1 120 tons
Pw2 145 tons
Pu2 217.5 tons
ac1 .4 cm
bc1 .4 cm
ac2 .6 cm
bc2 .4 cm
S 5 m.
Cover 0.05 cm
Strap width 0.40 cm
hf (Footing) 0.55 cm
hs (Strap) 1 cm

1-Determine footing dimensions


Assume e = 1.22 m.
S1 = 3.78 s1
Rw1 = 1.1*(Pw1)*S / S1 116.40 ton
Rw2 = 1.1*(Pw1 + Pw2) - R1 131.10 ton
Footing (1) Dimensions
A1 =2 * ( a1/2 + e ) 2.85 m.
B1 = R1 / ( qsoil * A1 ) 4.10 m.
a1 = 2.50 m.
b1 = 3.40 m.
Footing (2) Dimensions
A2 = 3.20 m.
B2 = R2 / qsoil * A2 4.10 m.
a2 = 2.50 m.
b2 = 3.40 m.

2- Flexure Design for Footings


S 1 = S + aco1 / 2 - a1 = 3.95 m.
Ru1 = Pu1*S / (S1) = 151.71 ton
Ru2 = Pu1+ Pu2 - Ru1 = 185.79 ton

Footings Design
Footing (1)
qu1 = Ru1 / (a1*b1) 17.93 t/m²
Mf1 = qs*( b1/2 - bco1/2 )² /2 20.15 m.t
df 1 = 0.50 cm²
As 1 = 13.37 cm² / m'

1/3

Concrete Design Program (C.D.P)


Footing (2)

qu2 = Ru2 / (a2*b2) 21.88 t/m²


Mf2 = qs*( b2/2 - bco2/2 )² /2 24.59 m.t
df 2 = 0.50 cm²
Asf 2 = 16.47 cm² / m'

3 -Wide beam action (Shear)

Footing (1)

tributary area = w x A1 3.12 m²


qu1 = qs1 x tributary area /A1*df1 4.48 kg/cm²
qcu = 6.53 kg/cm² Ok

Footing (2)

tributary area = w x A2 3.12 m²


qu2 = qs2 x tributary area /A2*df2 5.47 kg/cm²
qcu = 6.53 kg/cm² Ok

5 - Strap beam straining action


Streses
qu1 = Ru1 / ( A1 ) 60.93 t/m
qu2 = Ru2 / ( A2 ) 74.36 t/m

Shear forces
Q1 12.19 ton
Q2 -107.81 ton
Q3 31.71 ton
Q4 124.60 ton
Q5 -92.90 ton
Q22 -95.63 ton
Q44 102.30 ton
Q55 -70.59 ton

Moment values

M1 1.22 m.t
M2 -29.10 m.t
M3 58.03 m.t
Mmax -94.18 m.t
M3L 23.99 m.t
M3R 33.50 m.t

6 - Flexure Deaign of Strap beam.


For Mmax
ds = 0.95 m.
bs = 0.40 m.
As 1 = 36.61 cm²
For M3L or M3R

As 1 = 11.88 cm²
2/3

Concrete Design Program (C.D.P)


7 - Shear Deaign of Strap beam.

Design for Q3 Critial section at free span of strap beam

qu =Qu / b.d 8.34 kg/cm²

qcu = 9.80 kg/cm²

qumax = 28.58 kg/cm² And less than 40 kg/cm²

qsu = qu - 1/2 qcu 3.44 kg/cm²

Ast / b.s = qsu /(fy /γs)


Ast = 1.57 cm²

S= 14.27 cm
µmin1 = 0.40/fy = Ast/(b.S)
Smax1 = 35.34 cm
Smax2 =0.15 or 0.1 % * µ 39.27 cm
Smax3 = 20 cm 20.00 cm

Smax= 20.00 cm

8 - Details

Footing (1)

Dimensions A1 (m.) B1(m.) hf1 (m.)


PC 2.85 4.10 0.35
RC 2.50 3.40 0.55

As1 12 F 12

Footing (2)

Dimensions A2 (m.) B2 (m.) hf2 (m.)


3.20 4.10 0.35
RC 2.50 3.40 0.55

As2 15 F 12

Strap Beam

Dimensions bs (m.) hs (m.)


0.40 1.00

As3 19 F 16
As4 6 F 16
Stirrup reinforcement

Rinforcement /m' Branch number


As5 5 10 \m. 2

3/3

Concrete Design Program (C.D.P)