Note!
The pump is set to Proportional Pressure,
Table, overview of operating mode.
curve three, on delivery.
To show the setting currently in use by the pump, This must be manually changed to Constant
give the button a short press . Read the selected Pressure by the installer when the pump is
mode by studying the settings menu. After two used in floor heating installations.
seconds the indicator returns to operating mode.
SE.33.C.178.1509
1
Assembly instructions | Grundfos UPM3 Auto L 15/70
Settings menu
Display Indication Operation Action
Red LED, Electric Pump stops Check volt-
Yellow LED fault because of age to pump
#3 low voltage or / Replace
serious fault pump
Dimensions
72 45 128
36 92
130
90
G1 Weight 1,9 kg
Pump diagram
Lock
The pump can be locked so that it is not possible
to show or change settings. In order to lock/ Electrical contact
unlock the pump then press the button for
more than 10 seconds.
SE.33.C.178.1509