Brochure, Jasco V-750 UV-Vis Double Beam Spectrophotometer
Brochure, Jasco V-750 UV-Vis Double Beam Spectrophotometer
Brochure, Jasco V-750 UV-Vis Double Beam Spectrophotometer
JASCO Corporation - Japan was founded in 1958 “serving the Science and Technology World
to provide the scientific community with optical by providing most advanced analytical
spectroscopy products.
instrumentation”
In the mid-1950's a group of researchers in the
Institute of Optics of what is now Tsukuba With the introduction of HPLC in the mid-1970's
University needed an Infrared JASCO's experience in highly sensitive and accurate
Spectrophotometer for their research. optical systems led to the development of a series
Since a commercially available instrument was of chromatographic detection systems. Fixed and
not yet existing at the time, they undertook the variable wavelength UV/Visible and Fluorescence
challenge to develop their own. detectors were introduced featuring excellent
sensitivity and reliability in compact modules. In
The result was quite a success - a reliable order to offer complete HPLC systems JASCO
instrument with excellent optical performance. developed a variety of novel solvent delivery
As a second result, other research groups asked systems as well as other accessories such as column
them to replicate the instrument for use within ovens, autosamplers, and PC based control and
their laboratories. analysis software.
Today JASCO offers a wide variety of HPLC modules,
accessories and analysis software. The new JASCO
LC-4000 Liquid Chromatography series is designed
to operate at pressures approaching 15,000 psi for
either gradient or isocratic separations, providing
researchers with a powerful tool when using the
new generation of small particle columns. LC-4000
Series includes a versatile series of components
offering unique flexibility to build systems for
Over the years the JASCO product line has grown routine and specialized applications. LC-4000
to cover instruments used, not only in research features the widest choice of optical HPLC detector:
but also for routine analysis applications in areas UV, diode array, fluorescence, chemiluminescence,
such as quality control, environmental analysis, CD, chiral and refractive index detector.
and process control. The current spectroscopy
product line encompasses instrumentation for Finally JASCO’s modular Supercritical Fluid
the following methods: Chromatography and Supercritical Fluid Extraction
platforms provide a low-cost, fast, green technology
• UV/Visible and NIR with reliable and worry-free performance for a wide
• Microscope Spectrophotomers variety of applications.
• FT-IR, microscope FT-IR and FT-Raman
• Dispersive RAMAN
• Polarimeters
• Spectrofluorometers
• Portable Raman
• Portable FT-IR
• Fully Automated Dissolution Tester
JASCO Europe is responsible for marketing, sales, With its service network, JASCO is ready to maintain
service and support for all Jasco products the perfect reliability of customer's instrumentation
throughout Europe, Middle East and Africa. and minimize the laboratory down time.
· Superior productivity
· Optimized analytical performance
· Lower cost of ownership
· Extended instrument life
If your laboratory has specific Service and Support
requirements, JASCO can help you with customized
contract agreements. In addition, a full set of
Installation Qualification (IQ), Operational
Qualification (OQ), and Performance Qualification
(PQ) tests are available to verify the system proper
installation, operation and performance,
respectively.
JASCO Europe S.r.l.
Via Cadorna, 1 - 23894 Cremella (LC) Get the most from your investment with
Tel. +39-0399215811 JASCO Training Courses
Fax +39-0399215835
JASCO Training Courses ensure maximum skill
[email protected] development for the best value of your laboratory.
Our team of highly-experienced specialists can help
www.jasco-europe.com
your staff to get the most from your instrument
Follow us on:
reducing your analysis run time and improve
performance.
Build your knowledge with JASCO Training Courses:
Make the most of your investment with · Instrument and Software operation
JASCO Service and Support · troubleshooting
· Maintenance
JASCO Service and Support agreement plans are
· Calibration
designed for those laboratories pursuing
· Applications and Methods developments
superior productivity through the highest level
· Operating Techniques
of professional services.
The use of automated instrumentation is the
right approach to meet today's laboratories
productivity requirements, reducing analysis run
times, enhancing sample throughput, and
increasing analytical accuracy and precision. In
this view, preventive maintenance is very
important to maximize laboratory uptime and
avoid unexpected expenses.
In addition to the analytical goal, proper
installation and maintenance are required to
achieve optimal performance. JASCO provides
flexible service and support management
solutions focused on your laboratory real
objectives.
V-750 Spectrophotometer
Micro Volume Measurement - The spectral Film thickness measurement - Film thickness
bandwidth settings of V-750 has ‘L’ Mode and measurements can be made using the SLM-907
‘M’ Mode settings. The ‘L’ Mode is effective for specular reflectance accessory and integrated as
measurement of highly absorbing samples. The standard Film Thickness measurement program.
‘M’ Mode focuses the incident beam for The film thickness of a food packaging film using the
accurate measurements of trace amounts of SLM-907 single reflection accessory is shown below.
sample in a micro cell.
Micro volume measurement can be made by
using a cell with a 2 mm width and setting the
spectral bandwidth to an M-mode slit; useful for
measurement of volume limited liquid samples.
One Drop accessory also allows easy volume
measurement as low as 600 nL.
Alignment-free lamp replacement - The design True Double-Beam spectrophotometer - All JASCO
of the socket deuterium lamp and socket V-700 spectrophotometers are true double-beam
tungsten halogen lamp facilitates light source systems, provide the best possible stability and
over replacement, simplifies maintenance and allow reference to be measured and corrected in
reduces operation error. real time.
In the example below, single beam spectra and
validation results of 4 different lamps mounted
without any alignment tools.
― Lamp1
― Lamp2
― Lamp3
― Lamp4
• Standard working range (190 to 900 nm) and • IQ Accessory function for automatic recognition
variable spectral bandwidth from 0.1 nm enough of any accessory inserted into the sample
to satisfy any requirements. compartment.
• Outstanding RMS noise (0.00003 Abs) and • Validation and Daily Check programs help
Dynamic Range (5 Abs) provide capabilities from operator to keep the instrument always in perfect
education and routine analysis to high-end conditions assuring maximum accuracy of
research applications. obtained results.
• Diffuse reflectance measurement using • The V-700 Series can be integrated with more
Integrating Spheres with a light trap which can than 70 accessories and over 30 optional
be used to include or exclude the specular programs to offer flexible configurations for a
component. wide variety of analytical requirements.
• The ‘L’ Mode and ‘M’ mode spectral bandwidth • Cross-platform software package, SPECTRA
settings for measurement of highly absorbing MANAGER II, for controlling JASCO spectroscopic
samples or for accurate measurements of trace instrumentation, upgradable on-field to CFR
amounts of sample in a micro cell. version.
The SPECTRA MANAGER II program is a CANVAS PROGRAM - JASCO Canvas Program allows
comprehensive package for capturing and the user to prepare publication quality layouts of
processing data, eliminating the need to learn spectra, measurement parameters, text, images
multiple software packages and offering the user (BMP and WMF formats) to meet the user’s own
a shallower learning curve. Several types of report requirements. The program also includes a
measurement data files can be viewed in a single set of drawing tools for professional documentation.
window, and processed using a full range of data Newly created documents can be stored as
manipulation functions. templates for routine data presentation.
The basic package includes:
VALIDATION PROGRAM – The Validation program
QUICK START MEASUREMENT PROGRAM - The offers assistance for verifying instrument
Quick Start Measurement Program can performance to meet regulatory requirements set
automatically perform a series of operations as by GxP. The test methods are compliant with USP,
specified by a user, from measuring samples and EP and JP procedures. The program includes
processing data to saving and printing results, validation tests for wavelength accuracy, wavelength
with a single click of the start button. The repeatability, photometric accuracy, photometric
procedure is stored in memory for repeated use. repeatability, resolution, resolution power, stray
The data processing functions include light, noise level, baseline stability and baseline
comparison of an obtained spectrum with flatness. Optional standards and tools are required
spectra specified by a user. for some validation tests.
FIXED WAVELENGTH PROGRAM - The Fixed SPECTRA ANALYIS PROGRAM - The spectra analysis
Wavelength measurement program measures program includes all typical data analysis and data
the photometric values of up to eight multiple manipulation functions.
wavelengths. A ‘cycle number’ and ‘wait time’
Furthermore, the film thickness measurement, color
are selectable, and the mean, standard deviation
analysis, and the enzyme activity calculation
and C.V. value for each wavelength are displayed
programs are provided as standard.
after completion of each cycle of sample
measurements. Data manipulation functions
• Spectral manipulations (zoom in, zoom out,
SPECTRUM PREVIEW FUNCTION - The spectrum rescale)
preview function allows a user to monitor • Overlay
changes to a spectrum by varying parameters in • Arithmetic operations
real-time. A spectrum can be rapidly obtained • Spectral Subtraction
using the maximum scanning speed available. • Derivatives
This function allows verification of the optimum • Peak detection and processing - Find, Height,
set of instrument parameters and to check Area, FWHH
sample conditions before actual measurements. • Smoothing
• FFT Filter
TIME COURSE PROGRAM - The Time Course • Deconvolution
measurement program measures the changes of • Baseline correction
a sample’s photometric value over time at a • Unit conversion
fixed wavelength and with a defined interval. For
the time course measurement, the V-750 can AUTOMATIC SETUP - The response time is
obtain data at a minimum interval of 0.05 sec. automatically determined depending on the
Parallel time course measurements while selected bandwidth and scan speed so that the
controlling the cell positions of a cell changer are spectrum profile does not become broad. The data
also possible. interval is also automatically determined depending
on the selected bandwidth.
V-750 - Technical Specifications
• Czerny-Turner mount
Optical System • Single Monochromator
• True Double-Beam (Sample & Reference)
Light Source Deuterium & Halogen lamps with automatic switching
Detector Photomultiplier tube
Wavelength Range 190 – 900 nm
Wavelength Accuracy ± 0.2 at 656.1 nm
Wavelength Repeatability ± 0.05 nm
Scanning Speed 10 to 4,000 nm/min (up to 8,000 in preview mode)
Slew Speed 12,000 nm/min
0.1, 0.2, 0.5, 1, 2, 5, 10 nm
Spectral bandwidth
L2, L5, L10 nm - M1, M2 nm
Photometric Range
-4 + 4 Abs
(guaranteed on the whole spectral range)
Maximum Photometric Range -5 + 5 Abs (KMnO4 aqueous solution)
±0.0015 Abs (0 to 0.5 Abs)
±0.0025 Abs (0.5 to 1 Abs)
Photometric Accuracy
±0.3 %T
Tested with NIST SRM 930
1 % (198 nm KCl 12 g/L)
Stray Light 0.005 % (220 nm NaI 10 g/L)
0.005 % (340 nm and 370 nm NaNO2 50 g/L)
Baseline stability ±0.0003 Abs/hour
Baseline flatness ±0.0002 Abs
RMS noise 0.00003 Abs (0 Abs, 500 nm, 60 sec)
Communication USB
Automatic Accessories Recognition YES
Spectra Manager II including the following programs:
• Spectra Measurement
• Quantitative analysis
• Fixed Wavelenght
• Dual Wavelenght Time Course Measurement
• Quick Start Measurement
Software
• Canvas
• Validation & Daily Check
• Spectrum Preview
• Film Thickness
• Color
• Enzyme Activity Calculation
Dimensions and weight 460(W)x602(D)x268(H) mm – 27 kg
Power requirements 150VA
Software & Sampling Accessories
V-750 UV-Vis Spectrophotometer
V-750 – Liquid Sample Accessories
Specifications
Rectangular cell
Sample Cell
pathlength 10, 20, 50 or 100 mm
Specifications
Rectangular cell
Rectangular cell Sample Cell
Reference Cell pathlength 10 mm
pathlength 10, 20, 50 or 100 mm
Rectangular cell
Capacity 1 sample and 1 reference cell Reference Cell
pathlength 10 mm
Temperature Ambient
Capacity 6 sample and 1 reference cell
• VWAC-796 - ASTM Color analysis program
Suggested • VWSC-797 - Saybolt color analysis program Temperature Ambient
Software • VWWQ-953 - Chromaticity/Turbidity
measurement program Cell Switching Software Controlled
• VWIS-957 - Interval scan measurement
Suggested program
FSE-702 - 4-position manual long path Software • VWIS-958 - Temperature interval scan
cell changer measurement program
Specifications
Rectangular cell
Sample Cell Specifications
pathlength 10, 20, 50 or 100 mm
Rectangular cell Cylindrical cell
Reference Cell Sample Cell
pathlength 10, 20, 50 or 100 mm pathlength 10, 20, 50 or 100 mm
Specifications Specifications
A cell height adjustment function provides the ability to The EMC-709 is a cell holder for a 50 μL micro cell.
use a 100 μL micro cell. A mask for a 100 μL micro cell is A 5 μL micro cell can be used with an optional spacer.
standard, 50 μL can be supplied as option.
Rectangular cell
Rectangular cell Sample Cell
Sample Cell pathlength 10 mm
pathlength 10 mm
Rectangular cell
Rectangular cell Reference Cell
Reference Cell pathlength 10 mm
pathlength 10 mm
Capacity 1 sample and 1 reference cell
Capacity 1 sample and 1 reference cell
Temperature Ambient
Temperature Ambient
Minimum
Minimum 5 μL
50 μL Cell Volume
Cell Volume
Specifications
Rectangular cell
Sample Cell
10 x 10 or 5, 2 or 4 x 10, 2 x 5 mm
Specifications
Rectangular cell
Reference Cell
Rectangular cell 10 x 10 or 5, 2 or 4 x 10, 2 x 5 mm
Sample Cell
10 x 10, 4 x 10, 2 x 10 mm
Capacity 6 sample and 1 reference cell
Rectangular cell
Reference Cell Temperature Thermostatted water circulation for
10 x 10, 4 x 10, 2 x 10 mm
Control sample and reference
Capacity 1 sample and 1 reference cell
Operating
10 to 90 degC
Temperature Thermostatted water circulation for Temperature
Control sample and reference
Cell Switching Software Controlled
Operating
10 to 90 degC
Temperature
MHT-745
Integrated variable speed magnetic Manual 4-position water thermostatted
Stirrer stirrer - 2 mm path width micro cell
turret cell holder
cannot be used with the stirrer
HMC-711
Water thermostatted micro cell holder
Specifications
Rectangular cell
Sample Cell
10 x 10, 4 x 10 mm
Specifications
Rectangular cell
Reference Cell
Minimum sample volume is 50 μL by using a rectangular 10 x 10, 4 x 10 mm
cell, 5 mm path length and 2 mm path width.
Capacity 4 sample and 1 reference cell
Rectangular cell
Sample Cell Temperature Thermostatted water circulation for
10 x 10 or 5, 2 or 4 x 10, 2 x 5 mm
Control sample and reference
Rectangular cell
Reference Cell Operating
10 x 10 or 5, 2 or 4 x 10, 2 x 5 mm 10 to 90 degC
Temperature
Capacity 1 sample and 1 reference cell
Cell Switching Manual
Temperature Thermostatted water circulation for
Control sample and reference
Operating
10 to 90 degC
Temperature
• Mask for 100 μL cell (2 pcs.) for
Cell masks micro cell, 2 x 10 mm
(standard) • Mask for 200 μL cell (2 pcs.) for
micro cell, 4 x 10 mm
V-750 – Liquid Sample Accessories
Rectangular cell
Specifications Sample Cell
10 x 10, 4 x 10, 2 x 10 mm
Rectangular cell Rectangular cell
Sample Cell Reference Cell
10 x 10, 4 x 10, 2 x 10 mm 10 x 10, 4 x 10, 2 x 10 mm
Rectangular cell Capacity 1 sample and 1 reference cell
Reference Cell
10 x 10, 4 x 10, 2 x 10 mm
Sample only
Temperature
Capacity 1 sample and 1 reference cell Heating/cooling system using Water
Control ETCS-761
cooled Peltier effect
Temperature Sample only - Heating/cooling system
Control using air cooled Peltier effect Sample & Reference
Temperature
Heating/cooling system using Water
Operating Control ETCR-762
10 to 60 degC (at 25 degC) cooled Peltier effect
Temperature
0 to 100 degC
Temperature Operating
±0.1 degC (cell holder sensor) for cooling water temperature at 25
control accuracy Temperature
degC
With cell holder sensor Temperature
±0.5 degC (20 to 40 degC) ±0.1 degC (cell holder sensor)
Temperature control accuracy
±1 degC (other temp. range)
Accuracy With cell holder sensor
With optional temperature sensor
±0.5 degC (20 to 40 degC)
±0.2 degC Temperature ±1 degC (other temp. range)
Integrated variable speed magnetic Accuracy
With optional temperature sensor
Stirrer stirrer - 2 mm path width micro cell ±0.2 degC
cannot be used with the stirrer
Integrated variable speed magnetic
• VWIS-958 - Temperature interval scan
Stirrer stirrer - 2 mm path width micro cell
measurement program
Suggested cannot be used with the stirrer
• VWTP-959 - Temperature Gradient
Software measurement and DNA melting analysis
• VWIS-958 - Temperature interval scan
program
measurement program
Suggested
• VWTP-959 - Temperature Gradient
Software measurement and DNA melting analysis
CSP-909 program
Lid for sample compartment with syringe port
Options
Cell Mask kit - includes sample masks and a cell-height
adjustment stand to raise the cell height. Using the cell-height
Specifications adjustment stand, a 2 mm path width micro cell can be used to
measure sample with a minimum 100 μL volume.
When monitoring a substrate-enzyme reaction, this accessory
allows addition of an enzyme solution without opening the OPS-515 - In-cell sensor with holder (factory option) - This is an
sample chamber lid. Can only be used with a 10 x 10 mm optional sensor which can be used to monitor the temperature
rectangular cell. Required needle length for the syringe is 50 inside of the sample cell.
mm
Cell Spacers - Spacers for cells with an optical path length of 1,
Compatible Cell STR-733 2 and 5 mm are available.
Holder EHCS-760 - ETCS-761 - ETCR-762
Capillary adapter - The capillary adapter is used for a capillary
P/N 0507-0220 – Micro syringe 10μL cell (minimum sample volume of 3 μL). The optional sensor
Syringe (OPS-515) in the cell adapter is required for temperature
P/N 0507-0223 – Micro syringe 100μL
monitoring.
V-750 – Liquid Sample Accessories
Specifications Specifications
Rectangular cell Rectangular cell
Sample Cell Sample Cell
10 x 10, 4 x 10, 2 x 10 mm 10 x 10, 4 x 10, 2 x 10 mm
Rectangular cell Rectangular cell
Reference Cell Reference Cell
10 x 10, 4 x 10, 2 x 10 mm 10 x 10, 4 x 10, 2 x 10 mm
Capacity 6 sample and 1 reference cell Capacity 6/8 sample and 1 reference cell
Sample only - Heating/cooling Sample only
Temperature Temperature
system utilizing air cooled Peltier Heating/cooling system utilizing
Control Control PAC-743
effect Water cooled Peltier effect
Operating Sample & Reference
10 to 70 degC (at 20 degC) Temperature
Temperature Heating/cooling system utilizing
Control PAC-743R
Water cooled Peltier effect
Temperature
±0.1 degC (cell holder sensor)
control accuracy Operating
0 to 100 degC (at 20 degC)
Temperature
With cell holder sensor
±0.5 degC (20 to 40 degC) Temperature
Temperature ±0.1 degC (cell holder sensor)
±1 degC (other temp. range) control accuracy
Accuracy
With optional temperature sensor With cell holder sensor
±0.2 degC Temperature
±0.5 degC (20 to 40 degC)
Accuracy
±1 degC (other temp. range)
Integrated variable speed magnetic
Stirrer stirrer - 2 mm path width micro cell Integrated variable speed
cannot be used with the stirrer magnetic stirrer - 2 mm path
Stirrer
• VWIS-958 - Temperature interval scan width micro cell cannot be used
measurement program with the stirrer
Suggested
• VWTP-959 - Temperature Gradient
Software measurement and DNA melting analysis • VWIS-958 - Temperature interval scan
program measurement program
Suggested
• VWTP-959 - Temperature Gradient
Software measurement and DNA melting
Options analysis program
MCB-100 Specifications
Mini Water Circulation Bath
10 degC below ambient temperature to 40 degC
Temperature control range
(IN and OUT connected)
How to configure it
Cell block In-cell sensor
# Compatible Cell #
(Cell and temp. sensor are optional) (factory option)
Specifications
The SAH-769 One Drop accessory is a dedicated
accessory for the V-700 Series to measure micro volume 1) Drop sample on the cell
samples of protein and nucleic acid. The 1mm and 0.2
mm cells are included as standard with accessory.
1mm pathlenght 5 μL
0.2mm pathlenght 0.6 μL
2) Close the cover glass and the lid
Precision of Quantitative Analysis of sample compartment
Solutions of Calf Thymus DNA (KH2PO4 / NaOH
buffer at pH7) at several concentrations were
measured by using cells with 1-mm. The spectrum
has shown at Figure 1 and LDL has shown at Table 1.
Measurement Parameters
Data interval: 0.5 nm
Measurement range: 220 to 315 nm
Band width: 1.5 nm
Response: Medium
Scan Speed: 200 nm/min
Figure 1
Absorbance spectra of DNA solution
More information on Application UV-0018-E
[optical path: 1 mm]
V-750 – Liquid Sample Accessories
ASU-800 autosampler, combined with a syringe pump and a flow cell or a variety of sippers, automatically measures multiple
liquid samples using spectrophotometer V-700 series. Tubes or tube racks according to the sample volume and the amount
of samples, or dedicated racks for microplates can be purchased separately. PC control software is included as standard.
Rack Tube/Microplate/Vials
6989-J111A – SRA-811 6774-H110A
15 mm O.D. test tube rack - 100 samples 15 mm O.D. test tube, 15 mm (O.D.) x 105 mm (H) - 10 mL - 100 pcs/set
6989-J112A – SRA-812 6774-H109A
13 mm O.D. test tube rack – 100 samples 13 mm O.D. test tube, 13 mm (O.D.) x 100 mm (H) - 7 mL - 100 pcs/set
6989-J113A – SRA-813 6905-H146A
12 mm O.D. test tube rack – 150 samples 12 mm O.D. test tube, 12 mm (O.D.) x 105 mm (H) - 5 mL - 100 pcs/set
6989-J114A – SRA-814 6774-H111A
10 mm O.D. test tube rack – 150 samples 10 mm O.D. test tube, 10 mm (O.D.) x 90 mm (H) - 3 mL - 100 pcs/set
6989-J116A - SRA-816
Commercially available 1ml 96-well microplates
Microplate Rack – 192 samples
6989-J117A - SRA-817
Commercially available 1ml 96-well microplates
Thermostatted Microplate Rack – 192 samples
6989-J118A – SRA-818 0410-0102
Vial Rack Screw top vial – 1.5 mL - 500 pcs./set
Specifications
Nozzle SUS-316 - 1.5 mm (O.D.) x 1.1 mm (I.D.)
Tubing Teflon – 2.0 mm (O.D.) x 1.0 mm (I.D.)
Fully controlled by Personal Computer - Included as standard: Spectra Measurement, Quantitative
Software
Calibration, Quantitative Analysis and Fixed Wavelenght Measurement
Communication USB
Specifications Specifications
NQF-781 can be used in conjunction with the NQF-783 can be used in conjunction with the
autosampler ASU-800. autosampler ASU-800.
A 10 mm rectangular cell holder is integrated in addition A 50 mm rectangular cell holder is integrated in addition
to the 10 mm flow cell, and can be easily switched. to the 50 mm flow cell, and can be easily switched.
Optical Pathlenght 10 mm Optical Pathlenght 50 mm
Cell Capacity about 50 μL Cell Capacity about 1400 μL
Cell Material Quartz Cell Material Quartz
Carryover Less than 1% Carryover Less than 1%
Minimum sample 0.7 mL Minimum sample 2.4 mL
requirement for low-viscosity samples requirement for low-viscosity samples
Specifications
NPF-782 can be used in conjunction with the autosampler ASU-800.
A 10 mm rectangular cell holder is integrated in addition to the 10 mm flow cell, and can be easily switched.
The sample can be recovered by reversing the ‘drain’ direction.
Optical Pathlenght 10 mm
Cell Capacity about 50 μL
Cell Material Quartz
Carryover Less than 1%
Minimum sample requirement 0.7 mL for low-viscosity samples
Material in contact with sample/solvent Teflon, Fluoroelastomer, Aflon
Maximum Processing Capacity 360 samples/hour
220 - 900 nm (V-750/760)
Wavelength Range 220 - 2200 nm (V-770)
220 - 1600 nm (V-780)
V-750 – Liquid Sample Accessories
Specifications Specifications
The ASP-849 can be used in 6156-H607A
conjunction with the ASU-800 and 5 mm path length flow cell
SFC-712/MFC-714/FIC-715 flow cell (50 μL cell capacity)
holders. The syringe pump is suitable Flow Cell compatibility
for drawing small quantities of 6156-H608A
sample. 10 mm path length flow cell
(100 μL cell capacity)
Reproducibility of
Within ±1%
volume delivery Flow Cell Rectangular Quartz
Syringe volume 2.5 mL (included as standard) Material in contact Teflon, Fluoroelastomer,
with sample/solvent Quartz
Optional syringes 1 mL – 5 mL – 10 mL
220 - 900 nm (V-750/760)
Material in contact Teflon, Fluoroelastomer, Wavelength Range 220 - 2200 nm (V-770)
with sample/solvent Quartz 220 - 1600 nm (V-780)
SFC-712
Compatible
MFC-714
Flow Cell Holders
FIC-715
MFC-714– Micro Flow cell holder LFC-713 – Long path flow cell holder
FIC-715 – Micro Flow cell holder
Specifications
6522-J343A
30 mm path length flow cell
Specifications (approx. 0.6 mL cell capacity)
6522-J333A
MFC-714: SUS Flow Cell compatibility 50 mm path length flow cell
Cell Material
FIC-715: Teflon (approx. 1 mL cell capacity)
Optical Pathlenght 10 mm 6522-J243A
100 mm path length flow cell
Cell Capacity 20 μL (approx. 2 mL cell capacity)
Flow Cell Synthetic Fused Silica
220 - 900 nm (V-750/760)
Wavelength Range 220 - 2200 nm (V-770)
220 - 1600 nm (V-780)
V-750 – Solid Sample Accessories
Specifications Specifications
FLH-740 accessory are used to measure the FLH-741 accessory are used to measure the
transmittance of solid, transparent samples such as films, transmittance of solid, transparent samples such as films,
plate glass, and filters. plate glass, and filters.
Minimum Minimum
15 mm (H) x 15 mm (W) 5 mm (H) x 5 mm (W)
Sample size Sample size
Maximum Maximum
80 mm (H) x 100 mm (W) 80 mm (H) x 100 mm (W)
Sample size Sample size
Sample Sample
0.5 to 10 mm 0.5 to 25 mm
Thickness Thickness
Insert Mode Leaf Spring type Insert Mode Holding Plate type
RSH-744 – Rotary sample holder VTA-752 – Film holder (variable incident angle)
Specifications Specifications
RSH-744 accessory can be used to measure a film type VTA-752 is a film holder to measure transmittance of a
sample and rotating the sample manually. film type sample, changing the incident angle of the light
The sample can be rotated 360º around the optical axis beam.
and the inclination (tilt) of the sample versus the source The incident angle of the source light beam can be set in
beam can be varied within a range of ±50º. 1º increments.
Minimum Minimum
10 mm (H) x 30 mm (W) 15 mm (H) x 35 mm (W)
Sample size Sample size
Maximum Maximum
18 mm (H) x 38 mm (W) 80 mm (H) x 70 mm (W)
Sample size Sample size
Sample Sample
1 to 2 mm 1 to 2 mm
Thickness Thickness
Rotation Optical axis: 360º Rotation
±90º
Angle Perpendicular to the optical axis: ±50º Angle
V-750 – Solid Sample Accessories
Specifications
SLM-908 accessory is designed to measure the relative
Specifications reflectance of a sample using the reflected light from an
aluminum-deposited plane mirror as a reference. This
SLM-907 accessory is designed to measure the relative accessory allows measurement of the reflectance of metal-
reflectance of a sample using the reflected light from an deposited films and/or metal Plating, as well as measurement
aluminum-deposited plane mirror as a reference. of film thickness using a film thickness analysis program. SLM-
This accessory allows measurement of the reflectance of 908 accessory can measure larger samples such as 6 inch
metal-deposited films and/or metal Plating, as well as silicon wafers.
measurement of film thickness using a film thickness analysis
program. Incident angle Approx. 5º
Specifications
VWRR-769
DPL-515 depolarizer converts incident light to non-polarized
Reflectance correction program light. Non-polarized light is obtained when the rotation angle
VWRR-769 program can convert a relative reflectance is set to 45º. The applicable spectral range is from 350 to 2,500
nm.
spectrum, obtained by using a specular reflectance
accessory, to an absolute reflectance spectrum by
multiplying the absolute reflectance spectrum of the GPH-506 – Polarizer
reflectance standard with a relative reflectance
spectrum of the sample.
VWRR-769 software includes typical absolute Specifications
reflectance data of an evaporated aluminum mirror for
conversion. GPH-506 polarizer converts the source light from the
instrument monochromator into linearly polarized light. The
Required plane of polarization can be set at 0º (vertical linearly
SLM-907-SLM-908
Accessories polarized light) and 90º (horizontal linearly polarized light).
The applicable spectral range is from 215 to 2,300 nm.
V-750 – Solid Sample Accessories
Specifications Specifications
The ISV-922 integrating sphere are provided with a light trap so that ILV-924 integrating sphere are provided with a light trap so that the
the reflectance of samples can be measured with or without the reflectance of samples can be measured with or without the specular
specular reflectance component. The rectangular cell holder for reflectance component. The rectangular cell holder for diffuse
diffuse transmittance of a turbid liquid sample and holders for diffuse transmittance of a turbid liquid sample and holders for diffuse
reflectance of solid samples are standard. A range of sample holders, a reflectance of solid samples are standard. A range of sample holders, a
fluorescence cut filter and polarizer are available as options. fluorescence cut filter and polarizer are available as options.
PSH-003 Powder sample holder - For diffuse reflectance SSH-507 Solid sample holder
measurements of small amount of powder samples - Size of sample For diffuse transmittance measurements of a solid sample
area: 5 mm diameter - Thickness: 0.5 - 4 mm - (*) The lens and mask kit Min. sample size: 20 (H) x 20 (W) x 0.5 (t) mm
is required Max. sample size: 70 (H) x 30 (W) x 40 (t) mm
SSH-506 Solid Sample Holder Integrating spheres are designed to measure either the diffuse
For diffuse transmittance measurements of a solid sample transmittance or diffuse reflectance of a sample. Usually, the UV-
Min. sample size: 20 (H) x 20 (W) x 0.5 (t) mm Vis/NIR spectrophotometers measure the transmittance of a
Max. sample size: 70 (H) x 40 (W) x 35 (t) mm homogeneous, transparent liquid or solid sample. However, when a
turbid liquid sample or opaque solid sample is measured, the light
RLH-603 Reference Side rectangular cell holder incident upon the sample is diffusely transmitted or reflected and only
This cell holder is used for the reference side when performing diffuse a small portion of the light reaches the detector. The integrating
transmittance measurements of turbid liquid samples. Cell to be used: sphere accessory acquires the light diffuse-transmitted or diffuse-
5, 10 or 20 mm optical pathlength rectangular cell reflected from the sample into the integrating sphere and introduces it
to the detector.
(*) 6916-H123A Lens and mask kit
This accessory kit consists of a lens to focus the light beam onto a
small amount of a powder sample and three types of masks (1, 2, 3
mm diam.). The lens focuses the beam down to a 1 mm diameter by
using the 1 mm diam. mask for diffuse reflectance measurements of a
very small area of the sample.
V-750 – Solid Sample Accessories
Specifications Specifications
SIV-767 includes a rectangular cell holder for diffuse PIV-756 can mount samples horizontally and allows the
transmittance of a turbid liquid sample and holders for simple measurement of small and powder samples with
diffuse reflectance of solid samples as standard. The little to no sample preparation.
standard magnetic stirrer for a 10 mm path length
rectangular cell enables diffuse transmittance Inside diameter of
60 mm
measurements of turbid liquid samples, using the stirrer integrating sphere
to maintain sample homogeneity. Minimum sample size
A thermostatted cell holder for the 10 mm rectangular 3 mm diam.x 0.5 (T) mm
(Transmittance)
cell is also available as an option.
Maximum sample size
Inside diameter of 50 (H) x 50 (W) x 2 (T) mm
60 mm (Transmittance)
integrating sphere
Maximum sample size
Cell Rectangular cell 30 x 30 x 10 (T) mm
(Reflectance)
(Sample side) 5, 10, 20, 30, 50 mm path length
Reflectance 20 mm diam. x 2 mm
Cell Rectangular cell measurement adaptor (no window required)
5, 10, 20 mm path length
(Reference side) Wavelength range 250 - 850 nm
* Reference cell block is optional
Minimum Sample size 20 (H) x 20 (W) x 0.5 (T) mm On-board Detector PMT
Reflectance measurement
Options
Maximum Sample size 65 (H) x 50 (W) x 25 (T) mm
Reflectance measurement 6916-J156A - Lens and mask for reflectance
measurement - (mask size: 1, 2 and 3 mm diam.)
Wavelength range 250 - 800 nm
Integrated variable speed 6916-J256A - Lens and mask for transmittance
Stirring system
magnetic stirrer measurement - (mask size: 1, 2 and 3 mm diam.)
On-board Detector PMT These lens and mask kits are used to focus the light
Options beam for measurement of a small area. When the 1 mm
diameter mask is used, the beam diameter of the
RLH-603 Reference-side rectangular cell holder incident light upon the sample is decreased to a
This cell holder is required for the reference side when performing minimum of 2 mm in diameter.
diffuse transmittance measurements of turbid liquid samples. The 5,
10 and 20 mm pathlength rectangular cells can be used with this cell
holder.
Specifications Specifications
IJV-726 is specially designed to measure the diffuse
HISV-728 accessory is suitable for the diffuse reflectance
transmittance and diffuse reflectance of small and
measurement of a sample which cannot be
irregularly shaped samples such as gemstones. Various
accommodated in the standard sample chamber. Select
sample holders are included as standard for
from the optional, dedicated optical fibers of 1 or 2
measurements of precious stones mounted on rings and
meter length, as required.
necklaces. Use with the GHP-506 polarizer (option) is
recommended. Inside diameter of
60 mm
Inside diameter of integrating sphere
60 mm
integrating sphere
Windows Size 25 mm diameter
Minimum sample size 2 mm diameter
(Transmittance/Reflectance) Wavelength range 250 - 800 nm
Maximum sample size On-board Detector PMT
10 mm diameter
(Transmittance)
Options
Sample holders for rings, pearls, gemstones
(included as standard)
V-750 – Solid Sample Accessories
ARMV-919
Automated Absolute Reflectance
measurement accessory
Specifications
Wavelength range 250 - 850 nm
Movement of sample
Asynchronous
stage and detector
ARV-913 ARSV-916
Absolute Reflectance measurement accessory Absolute Reflectance measurement accessory
(Synchronous type) (Asynchronous type)
Specifications Specifications
The ARV-913 accessory provides absolute reflectance The ARSV-916 accessory provides absolute reflectance
measurements of samples by the manual, synchronous measurements of samples by the manual, asynchronous
movement of the sample stage and detector. movement of the sample stage and detector, thus, the
Changing the incident angle of the sample by manually moving positions of the sample stage and detector can be
the detector position, the absolute reflectance of the sample independently varied to obtain the absolute reflectance and
can be measured at varied incident angles. transmittance spectra of the sample at varied incident and
Using the optional ARG-476 or GPH-506 polarizers, the detection angles.
polarization properties of the sample can also be examined. Using the optional ARG-476 or GPH-506 polarizers, the
polarization properties of the sample can also be examined.
Wavelength range 250 - 850 nm
Wavelength range 250 - 850 nm
Movement of sample
Synchronous
stage and detector Movement of sample
Asynchronous
stage and detector
Control of sample stage
Manual
and detector Control of sample stage
Manual
and detector
Absolute reflectance
Measurement mode Relative reflectance Absolute reflectance
Measurement mode Relative reflectance
Integrating sphere 60 mm
Integrating sphere 60 mm
Absolute reflectance mode
5º to 60º Absolute reflectance mode
Incidence angle 5º to 60º
Relative reflectance mode
Vertical incidence Relative reflectance mode
Incidence angle Vertical incidence
Angle setting 2.5º step (manual)
Transmittance mode
Minimum sample size 5º to 60º
20 (H) x 20 (W) x 1 (t) mm
(Absolute Reflectance)
Sample stage: 0.1º step (manual)
Maximum sample size Angle setting Detector stage: 1º step (manual)
70 (H) x 100 (W) x 10 (t) mm
(Absolute Reflectance)
Minimum sample size
20 (H) x 20 (W) x 1 (t) mm
Minimum sample size (Absolute Reflectance)
20(H) x 20(W) x 0.5(T) mm
(Relative Reflectance)
Maximum sample size
70 (H) x 100 (W) x 10 (t) mm
Maximum sample size (Absolute Reflectance)
70(H) x 100(W) x 10(T) mm
(Relative Reflectance)
Minimum sample size
20(H) x 20(W) x 0.5(T) mm
Accuracy ±1.5% at incidence angle of 6 ° (Relative Reflectance)
100% line flatness Within ±1% Maximum sample size
70(H) x 100(W) x 10(T) mm
(Relative Reflectance)
Polarizer Optional (ARG-476 or GPH-506 )
Accuracy ±1.5% at incidence angle of 6 °
Wide incident angle sample holder VWAS-969 is suitable for ARMV-919 accessory
This sample holder is attached to the sample stage to
allow an angle of incidence up to a maximum of 85º. VWAL-799
• 6708-H163A for ARV-913/ARSV-916 Average reflectance calculation program
• 6708-H460A for ARMV-919 VWAL-799 program calculates the average reflectance,
ARV transmittance, or absorption of a spectrum. The average
30(H) x 60(W) x 1(T) mm photometric value can be calculated by specifying the
Minimum sample size
wavelength range for a spectrum.
ARSV - ARMV VWAL-799 software is effective for the evaluation of
30(H) x 30(W) x 1(T) mm
Minimum sample size glass or film samples or for evaluating optical
components containing an interference pattern due to a
Maximum sample size 70(H) x 100(W) x 10(T) mm
film coating.
Incidence angle 0º - 85º
VWAL-799 software can also be used with the SLM-
907/908 single reflection measurement accessories.
PDU-755 Phase difference measurement unit
PDU-755 option provides the measurement of the
VWAP-794
reflectance phase difference and the transmittance
Phase difference measurement program
phase difference. It consists of an angle selective
VWAP-794 software is included in the PDU-755 phase
analyzer and the VWAP-794 phase difference
difference measurement accessory as standard.
measurement program (included)
VWAP-794 program measures transmittance and
Wavelength range 250 - 850 nm reflectance phase difference spectra with multiple
incident angles by using a polarizer and analyzer.
Polarization
0º - 90º
rotation angle
VWML-791
Multi layer film thickness analysis program
ARG-476 Polarizer VWML-791 software calculates the refractive index,
The ARG-476 is a Glan-Taylor polarizer and is extinction coefficient and film thickness of an unknown
recommended for absolute reflectance measurements layer of a multi-layer film by using the least squares
using incident angles of 30º or greater. By setting the method. The multilayer data is created by input of the
polarizer at 45º, the same result can be obtained as for predicted thickness of the unknown layer and selecting
measurements with non-polarized light. from standard sample data for the substrate and the
Wavelength range 250 - 850 nm individual layers from an optical constant library.
The simulation is executed based on the created
Polarization multilayer data. By creating the simulated waveform to
0º - 90º
rotation angle be similar to the unknown spectral waveform, the
program executes fitting calculations and calculates the
unknown thickness.
The criteria for thickness calculations are approx. 50 to
1,000 nm.
The optical constant libraries of metals, semiconductors,
isolators and polymers are included as standard.
V-750 – Solid Sample Accessories
Specifications Specifications
FAV-750 accessory consisting of an optical fiber unit and FAP-754 accessory can be used for sample
external detector, enables the measurement of bulky measurement using the internal detector of the
samples that cannot be set in the sample compartment spectrophotometer. The light from the main instrument
and/or samples that are in special environments. The is introduced to an optical fiber. The light from a sample
light from the main instrument is introduced to the is introduced to the detector of the spectrophotometer
optical fiber. The light from a sample is introduced to via a return optical fiber.
the external detector via the optical fiber.
Options
External detector Photomultiplier tube
6916-J154A
Wavelength range 250 - 800 nm Fiber connection port, Bundle type for FAP-754
Options 6916-J150A
6916-J254A Fiber connection port, FC connector type for FAP-754
Fiber connection port, Bundle type for FAV-750
6916-J151A
6916-J250A Fiber connection port, SMA connector type for FAP-754
Fiber connection port, FC connector type for FAV-750
6916-J251A
Fiber connection port, SMA connector type for FAV-750
Specifications
This interface is for introducing light from an external
light source into the spectrophotometer, and measuring
the spectrum of the external source. It can be used for
the spectral/intensity evaluation of external light
sources.
* For correction of the measured spectrum, a secondary
reference source is also required.
Options
1120-0109 - Optical fiber (bundle type), 1m
1120-0110 - Optical fiber (bundle type), 1.5m
V-750 – Additional Software Packages
Biochemical Softwares
VWKN-772 VWTP-959
Kinetics analysis program Temperature Gradient measurement and
VWKN-772 Kinetics Analysis program performs time
DNA melting analysis program
course measurements of multiple samples, plots the VWTP-959 temperature programming software offers
graphs and calculates the maximum reaction velocity DNA or protein melting analysis.
(Vmax), Michaelis Menten constant (Km) and the Hill Controlling the temperature of a Peltier accessory
constant (n). (single or multi-cell), the VWTP-959 provides
The program also supports calculation of inhibitor measurement of the absorbance at a specific
constant and determination of inhibitor type by wavelength during temperature changes, then
comparing data obtained with and without an inhibitor. calculates the melting temperature (Tm) from the
An automated cell changer can be utilized, enabling results of the measurement.
batch analysis of multiple data.
Suggested EHCS -760 - ETCS-761 – ETCR-762
Five types of plots Accessories PSC-763 - PAC-743
• Michaelis-Menten CFR compliant YES
• Lineweaver-Burk
• Hofstee
• Eadie VWIS-957
• Hill Interval scan measurement program
Calculation items VWIS-957 program measures spectra of samples
• Maximum reaction velocity (Vmax) automatically with a user-defined time interval between
• Michaelis-Menten constant (Km) scans. The final data array can be displayed as a 2-D
• Hill constant (n) spectral display; a 3-D spectral display; contour, color-
• determination of inhibitor type image or cross-section images; or 2-D displays of the
• inhibitor constant peak height/ratio, peak area/ratio, FWHM or peak shift
calculations. Data plots similar to the VWIS-957 software
CFR compliant YES can be obtained using the VWTS-958 data array.
VWIS-957 can be used with an automated cell changer
accessory for spectral data collection of multiple
samples.
VWPN-952
Protein nucleic acid quantitation program Suggested
NCP-705
Accessories
VWPN-952 program measures the absorbance of
CFR compliant YES
protein and nucleic acid solutions at specified
wavelengths and calculates the concentration of the
protein and nucleic acids based on a calculation method VWIS-958
selected from five different types listed below. It is
possible to select the wavelength for baseline correction
Temperature interval scan measurement
and to choose whether baseline correction is to be program
performed. Generally, correction is performed for turbid VWTS-958 program measures spectra of samples
solutions at a wavelength of 320 nm. Dilution rate automatically with a user-defined temperature interval
correction is also possible for the user-defined between scans, providing a data array similar to the
concentration calculation method. VWIS-957 program, but related to sample temperature.
VWTS-958 can be used with an automated cell changer
Available calculation methods and/or with Thermostatted Single or Multiple holders
• Absorbance ratio of 280/260 nm for spectral data collection of multiple samples.
• Absorbance ratio of 230/260 nm
• Warburg-Christian method NCP-705
Suggested
• User-defined absorbance ratio EHCS -760 - ETCS-761 – ETCR-762
Accessories
• User-defined concentration calculation PSC-763 - PAC-743
CFR compliant YES CFR compliant YES
V-750 – Biochemical Package
Biochemical Package
VWKN-772 VWTP-959
Kinetics analysis program Temperature Gradient measurement and
VWKN-772 Kinetics Analysis program performs time
DNA melting analysis program
course measurements of multiple samples, plots the VWTP-959 temperature programming software offers
graphs and calculates the maximum reaction velocity DNA or protein melting analysis.
(Vmax), Michaelis Menten constant (Km) and the Hill Controlling the temperature of a Peltier accessory
constant (n). (single or multi-cell), the VWTP-959 provides
The program also supports calculation of inhibitor measurement of the absorbance at a specific
constant and determination of inhibitor type by wavelength during temperature changes, then
comparing data obtained with and without an inhibitor. calculates the melting temperature (Tm) from the
An automated cell changer can be utilized, enabling results of the measurement.
batch analysis of multiple data.
Suggested EHCS -760 - ETCS-761 – ETCR-762
Five types of plots Accessories PSC-763 - PAC-743
• Michaelis-Menten CFR compliant YES
• Lineweaver-Burk
• Hofstee
• Eadie
• Hill
VWPN-952
Protein nucleic acid quantitation program
Calculation items VWPN-952 program measures the absorbance of
• Maximum reaction velocity (Vmax) protein and nucleic acid solutions at specified
• Michaelis-Menten constant (Km) wavelengths and calculates the concentration of the
• Hill constant (n) protein and nucleic acids based on a calculation method
• determination of inhibitor type selected from five different types listed below. It is
• inhibitor constant possible to select the wavelength for baseline correction
CFR compliant YES and to choose whether baseline correction is to be
performed. Generally, correction is performed for turbid
solutions at a wavelength of 320 nm. Dilution rate
correction is also possible for the user-defined
UCB-710 – Bio rectangular cell holder concentration calculation method.
VWPL-956 VWPC-955
PLS Quantitative program PCR Quantitative program
VWPL-956 (Partial Least Squares) software creates The VWPC-955 (Principal Components Regression)
calibration models from the spectra of standard samples software performs the principal component analysis for
at several known concentrations of the target multiple standard samples, creating a calibration model
component(s). A regression curve is then derived to characterizing the changes in concentration of target
provide a relationship between the spectra and the component(s) in the standards to quantify the target
concentrations of the target component(s). Next, a component(s) and provide quantitative analysis of
similar calculation is performed repeatedly with the unknown samples. The PCR software can be used for the
spectrum residual and concentration residual until the analysis of foods or polymers and as a non-invasive
error becomes sufficiently small to quantitate the target analysis method for cosmetics, etc.
components. Since this method can perform a
calibration without needing to know the characteristics
of all components, this method allows the analysis of
only the target compounds in a sample, which can also VWPA-785
include unknown components, such as natural foods or PCA Quantitative program
other multi-component PLS calibration model editing
program Calibration curve display samples. VWPA-785 (Principal Components Analysis) software
recognizes characteristic spectral patterns from spectra
of the standard samples, and creates PCA models for
classification of an unknown sample. The PCA models
VWCL-954 can then be used for analysis of unknown sample
spectra, identifying the 'class' of the spectrum which
CLS Quantitative program most closely matches the grouped standard spectra.
VWCL-954 (Classical Least Squares) software calculates This method can be used for acceptance inspections of
the virtual spectrum of each component from the pharmaceutical products and for quality inspection of
spectra of standard samples and the concentration foods, polymers, paints, etc.
information of all the components using the least-
squares method. Using a calibration model calculated
from the spectra of the pure components, batch
quantitation of all components in a sample is performed.
This program is effective only when all the components
in the multi-component spectrum are known. Since the
CLS program examines the contribution to the spectral
interaction between each component, this method is
suitable for quality control of manufactured products
whose component concentrations are well characterized.
V-750 – Additional Software Packages
VWCD-960 VWAC-796
Color diagnosis program ASTM Color analysis program
VWCD-960 software measures the spectrum of a sample VWAC-796 calculates the ASTM color of petrochemical
from 380 to 780 nm, performs color calculations of the products such as lubricating oil, diesel and heating oils
sample using the various color systems, and plots the based on the ASTM and JIS K2580 standards.
results on a selected color system graph.
The program also includes a function for providing a Required
LSE-701
pass/fail judgement according to pre-set criteria. It is Accessories
also possible to retrieve several measured spectra and
perform a batch calculation for the multiple spectra.
Light source A, D65, C, B, user-defined light source VWSC-797
Saybolt color analysis program
Viewing angle 2º, 10º
VWSC-797 program calculates the Saybolt color value of
Wavelength
Calculation 380~780 nm petrochemical product samples such as kerosene,
range gasoline and other fuels according to the Saybolt color
measurement standard (JIS K2580).
Calculation
5 nm, 10 nm
data interval Required
LSE-701
Accessories
Result table Maximum 100 files
VWHC-977 VWGC-976
Color evaluation (Hazen color) program Color evaluation (Gardner color) program
VWHC-977 software measures the spectrum of a sample VWHC-976 software measures the spectrum of a sample
from 380 to 780 nm and compare it to that for different from 380 to 780 nm perform color calculations and
Hazen color standards in terms of the color difference evaluate the Gardner color number based on Japanese
ΔE*ab the yellowness index YI, the chromaticity Industrial Standard (JIS) or other standards.
coordinate b* or the color at a specific wavelenght. The
JIS K 0071-2:1998
Hazen color for the sample can then be evaluated.
Standard Norms Testing methods for colour of chemical
JIS K 0071-1:1998 products – Part 2: Gardner colour scale
Testing methods for colour of chemical
Standard Norms ISO 4630-1:2004
products – Part 1: Estimation of colour in
Clear Liquids - Estimation of colour by the
Hazen units (platinum-cobalt scale)
Gardner colour scale - Part 1: Visual
ISO 6271:2004 Method
Clear Liquids - Estimation of colour by the
ISO 4630-2:2004
platinum-cobalt scale
Clear Liquids - Estimation of colour by the
ASTM D1209-05 Gardner colour scale - Part 2:
Standard Test Method for Color of Clear Spectrophotometric Method
Liquids (platinum-cobalt scale)
ASTM D1544-04:2010
Standard Test Method for Color of
Transparent Liquids (Gardner color scale)
VWLU-788
Luminous color measurement program ASTM D6166-97:2003
Standard Test Method for Color of Pine
VWLU-788 package measures a luminescence emission Chemicals and Related products
spectrum of a light emitting source such as an LED, and (Instrumental Determination of Gradner
perform color calculations. Results can be plotted in a color)
chromaticity diagram and pass/fail judgments can be
performed according to the pre-set criteria.
Viewing angle 2º, 10º
Wavelength
380-780 nm
calculation range
Calculation data
5 nm
interval
Chromaticity
(x, y), (u, v), (u’, v’)
coordinates
• Tristimulus value: XYZ
• dominant wavelength λd
(complementary wavelength λc)
• related color temperature Tcp
and deviation Δ uv (JIS Z8725)
Calculation items
• color rendering index Ra, R1~R15
(JIS Z8726)
• fluorescent lamp light source
color classification (JIS Z9112)
• pass/fail judgement.
VWBG-773 VWSE-798
Band gap analysis program UV Shield factor calculation program
VWBG-773 command calculates the band gap of a VWSE-798 command calculates the UV shield factor
semiconductor sample from the transmission and (shield factor =100 - transmittance) indicating the
reflectance spectra. Four calculation methods are amount of light blocked in a certain wavelength region.
available according to the type of electronic transition. A maximum of five wavelength regions can be specified
for calculations.
VWQM-978 VWRR-769
Spectrum quantitative measurement program Reflectance correction program
VWSQ-978 package provides the quantitative analysis
VWRR-769 program can convert a relative reflectance
for a maximum of ten peaks by applying the Beer-
spectrum, obtained by using a specular reflectance
Lambert law to each selected sample peak.
accessory, to an absolute reflectance spectrum by
Simultaneous determination of multiple components of
multiplying the absolute reflectance spectrum of the
a sample is possible if the absorption peaks of each
reflectance standard with a relative reflectance
component do not overlap. Two calculation methods are
spectrum of the sample.
available, using either the peak height or peak area of
VWRR-769 software includes typical absolute
the selected absorption peaks.
reflectance data of an evaporated aluminum mirror for
conversion.
VWST-774 Required
SLM-907/908
Solar/visible light measurement program Accessories
FCV-SPCMGR2 VWMC-972
Data file conversion program Macro command program
The FCV-SPCMGR2 package is a program to provide VWMC-972 software is a macro command software that
batch file conversion of multiple Spectra Manager data provides the ability to easily edit macro scripts, and
files to file formats usable by other processing programs. automatically execute a series of operations including
measurements, analyses and printing.
Conversion
• JASCO format (previous format)
• JCAMP-DX
• TXT formats to JASCO format (current format)
• JASCO format (current format) to TXT format
VWLK-777
Spectral concatenation program
VWLK-777 software offers the ability to concatenate
two spectral data files such as a UV-Vis/NIR spectrum
and mid-infrared spectrum.
JASCO Europe S.r.l. JASCO V-750 – Product Information Rev.1
Via Cadorna, 1 - 23894 Cremella (LC)
www.jasco-europe.com
Follow us on:
DISCLAIMER
The contents of this publication are for reference and illustrative purposes only. Information, descriptions, and specifications in this document are subject to
change without notice and cannot be used from third parts for data comparison and/or performance comparison. JASCO assumes no responsibility and will not be
liable for any errors or omissions contained herein or for incidental, consequential damages or losses in connection with the furnishing, performance or use of this
material.