DIN Rail Mounted Programmable Digital Timer Switch: Instruction Manual
DIN Rail Mounted Programmable Digital Timer Switch: Instruction Manual
COM
Instruction Manual
DIN Rail Mounted Programmable Digital Timer Switch
(DRTS-120 / DRTS-12)
Version 1.0 (Mar, 2016)
2. Specifications
Table 1. Specifications
Power supply voltage rating 110 VAC or 12 V AC / DC
Power consumption (MAX) 2W
Display type LCD
Mechanically 10,000,000;
Relay lifetime
Electrically: 100,000
Resistive load: 16 A / 250 V AC;
Load capacity Lagging load: 8 A / 250 V AC;
Lamp Load: 2000 W
Output relay 1 x form C relay (1 N.O., 1 N.C.)
Timer range 1 minute ~ 168 hours (7 days)
Figure 2(a). Wiring for 110 V version DRTS (DRTS-120).
Timer deviation +/- 1 second / 24 hours, 25°C
Power-off memory 60 days
Working temperature -14°F ~ 104°F ( -10°C ~ + 40°C)
Ambient humidity 35 - 85% RH
Power reserve 3 years (lithium battery)
Size 86.5 mm x 36 mm x 65.5 mm
Weight 120 g
3. Dimensions
2016.03 P1/3
AUBER INSTRUMENTS WWW.AUBERINS.COM
5. Timer Display and Key Pad switch (mode “ON”) or turn off the timer switch (mode “OFF”) by pressing the
5.1 Timer Display Window MANUAL key.
NOTE:
1) As the execution of relay events relies on the clock setting, please adjust
Table 2. Key Functions.
your clock first before programming the event timer.
Symbol Function
2) You can set up to 17 relay events on this timer switch. Each event has two
○
P Program the timer switch events timer settings: the time to activate the relay (displayed as “1 ON”, “2 ON”, and so
D+ Day adjustment on), and the time to deactivate the relay (displayed as “1 OFF”, “2 OFF”, and so
H+ Hour adjustment on).
M+ Minute adjustment 3) To cancel or disable an event, please make sure both the ON and OFF timer
🕒 Clock setting are cleared “ - - : - - “.
RESET Reset 4) When program the event timer, if no key is pressed for 10 seconds, the timer
Switch mode between ON / AUTO / OFF; display will automatically go back to normal display mode and no settings will
MANUAL
Clear / reset the timer event.
be saved.
5) To use the relay function, this timer must connect to external power supply.
The embedded battery only provide power to the clock/timer, it cannot energize
6. Setup the Timer Switch the coil of the relay.
1. When you first use this timer switch, press RESET key to reset this timer
switch. This will clear all programmed events and reset the clock.
2. Set the Clock: Press and hold the CLOCK key (🕒), then press "D+", "H+" or 5. Troubleshooting
"M+" key to adjust the day, hour or minute respectively to match with the If the relay had not been activated or deactivated at your pre-set time. Please
current time. do the following steps:
3. Set up ON/OFF timer of each event. Please follow the steps in the Table 3 to 1) Double check if the recurring weekday setting is correct for your event;
program the event. otherwise, just reset your event.
4. To have the timer switch run by the programmed events, set the mode to 2) If the date and time were set correctly for both the ON and OFF timer, but
“AUTO” using MANUAL key. At any time, you can manually turn on the timer the relay is pulling in or dropping out at unexpected time, please check other
2016.03 P2/3
AUBER INSTRUMENTS WWW.AUBERINS.COM
unused events one by one, and press MANUAL key to clear both the ON and
OFF timer to show “- - : - -”.
3) If your switch is still not working properly after performing 1) and 2), please
check if timer is running under “Auto” mode (In normal operation mode, press
Manual key to change).