Manaul of Au3tech System Laser Sudura
Manaul of Au3tech System Laser Sudura
Manaul of Au3tech System Laser Sudura
Version:V1.00
LIST
2.4 The modulation (PWM) working mode points out the light interface ........................................12
3. Parameter description......................................................................................................................................18
.................30
This document mainly for the Hws2000 hand-held laser welding equipment control part of the use,
installation and wiring, maintenance and so on to do. Before using this controller and related
equipment, please read this manual carefully to help you better use this equipment.
Due to the continuous updating of the product features, the products you receive may differ in some
1.Target Audience
Equipment operator
Equipment installer
1.Preface
This document mainly describes the use, installation, wiring and maintenance of the
control part of the HWS2000 handheld laser welding equipment. Before using this
controller and related equipment, please read this manual carefully to help you use this
equipment better.
Due to the continuous update of product functions, the product you received may differ
experience
Support continuous (CW) working mode and modulation (PWM) working mode
Support memorizing the parameter settings in the last working mode, which is
convenient for users to quickly put into work when switching between different modes
Support the user to save the process parameters, so that the saved parameters can be
quickly recalled when the machine is turned on next time, and the work efficiency is
improved
Support manual wire feeding and control the wire feeding direction
Support automatic wire feeding, automatic wire feeding after light emission, wire
welding
2. Interface description
2.1 Operation interface level switching diagram
After the system is powered on and initialized each time, it will enter the following interface:
Figure 2-2 Enter the interface by default after power-on
After the system is powerd on,the system enters the PWM working mode interface by
The continuous working mode interface is divided into the following three columns.
In the parameter setting column, users can set various parameters according to actual
Attention: The parameter value is based on the actual screen display value , The
parameter values shown in this figure are for explanation purposes only.
3.Control bar:
When the button is gray, it means that the function corresponding to this button is not
turned on, and when the button is colored, it means that the function corresponding to this
button is turned on. Click the button to turn on or turn off the function corresponding to this
button.
For example :
Indicates that the current laser has enabled, the red light indicator has not turned on, and the blowing
In continuous (CW) mode, click After clicking the button, the continuous light
图 2-7 调制(PWM)工作模式下连续出光界面
The modulation (PWM) working mode interface is also divided into 3 columns. Different from the
continuous (CW) working mode interface, the modulation working mode interface has more opt-out
mode buttons 。This button indicates the current mode of light emitting. Click this
button to switch the mode of light emitting. The device provides two modes of continuous light
When selecting the modulation (PWM) working mode, the laser power is determined jointly by the
analog quantity and PWM wave. At this time, the output power of the laser welding joint = laser power
* peak power *PWM duty ratio. Under the mode of selected modulation (PWM), the parameter
Settings on the interface are all effective, and users can set various parameters according to their
needs.
For the description of the control bar of continuous light output under the modulation (PWM) working
mode, please refer to the description of the control bar of the modulation (PWM) working mode in
Section 2.2.
2.4 The modulation (PWM) working mode points out the light interface
Under the continuous output light interface of modulation (PWM) working mode, click
button,You can switch to the modulation (PWM) mode of operation. The output
Work in modulation (PWM) mode of some directly out of the way of light, the number of PWM
pulse can be set user can set the maximum number of PWM pulse PWM pulse frequency value shall
not be higher than setting, i.e. some light time is less than 1 second user after the option radiates light
way, after pressed the trigger of laser welding head, the light time is determined by the setting of
PWM pulse number, the light time = / PWM frequency PWM pulse number.
Please refer to the description of the control bar of the point emitting light in the modulation
After clicking the button, you can enter the process setting/selection interface as
follows:
图 2-9 工艺设置/选择界面
For the continuous light output mode under the common modulation (PWM) working mode, the
process setting/selection function can set and save the welding process parameters commonly used or
preferred by the user. Input the current process name to be saved in the process name, such as steel
welding 3mm, and input at most 7 Chinese characters or 14 English letters in the process name.
After power on, the user can quickly set the parameters of continuous light emission in the
modulation (PWM) working mode through this function. After entering the interface and selecting the
process, click the button ,This set of process parameters can be selected as the current
parameters to be set, while switching to the modulation (PWM) mode of continuous light interface,
users can view the current selection of the process in the instructions.
For example, after selecting the process, click the OK button, jump to the modulation (PWM) mode of
continuous light interface, the interface parameters are automatically set to the parameters of the
selected process, users can also modify the selected process parameters according to their needs.
Users can save up to 6 sets of process parameters, automatically save after modifying the process
parameters, and directly access the saved process parameters after the next boot.
Click to enter the welding head setting interface. When setting this interface, you
To adjust the welding head motor speed, you can set the motor speed bar parameters for
adjustment control. The motor speed range is 0-100%, the larger the value, the faster the speed. The
motor stop delay column can set the motor stop delay time. The motor stop delay time range is
0-1800 seconds. The larger the value, the longer the delay time, as shown in Figure 2-12.
Figure 2-12 Welding head motor control
Click the wire feeding mode button to switch between automatic wire feeding and manual wire
In the automatic wire feeding mode, click to turn on the wire feeding. When the laser is enabled,
In manual wire feeding mode, set the wire feeding direction to wire feeding, and the wire feeder
will perform wire feeding after the wire feeding is turned on. Set the wire feeding direction to wire
return, and the wire feeder will return wire after the wire feed is turned on. In manual wire feeding
mode, it will not be controlled by laser enable, and the wire feeder will execute corresponding actions
To adjust the wire feeding speed, you can modify the parameters in the wire feeding speed
column to adjust, the range is 0-100%, the larger the value, the faster the wire feeding speed, as shown
in Figure 2-14.
For different welding processes, in order to prevent the welding wire from not fusing after the
light is stopped, the wire stopping time can be set in advance. Modify the parameters of early wire stop,
adjust the time of early wire stop, the range is 1-500mS, the larger the value, the longer the time, as
shown in Figure 2-14.
3. Parameter description
Blowing delay:
1)Before light emission: set the blowing delay time before light emission
2)After turning off the light: set the blowing delay time after turning off the light
Power delay:
1)Slow rise time: set the power slow rise delay (the time it takes for the power to increase from 0 to
2)Slow down time: set the power slow down delay (the time it takes for the power to drop from the
set power to 0)
Peak power:
Set the light output power of the welding head. In continuous (CW) mode, the output power is only
adjusted by analog quantity. In this mode, PWM does not participate in power setting, and the user
setting is invalid
Set to adjust the duty cycle of the PWM wave of the laser. In the modulation (PWM) mode, the welding
head power is adjusted by the peak power and the PWM duty cycle.
Welding head output power = laser power * peak power * PWM duty cycle.
PWM frequency:
Set and adjust the frequency of the PWM wave of the laser, and the frequency value adjusts the light
Set to adjust the number of pulses emitted by the PWM wave of the laser.
This parameter is only valid in the burst mode. In the point emitting light
mode, the number of pulses determines the point emitting light time. The
Motor speed:
Note: Please turn off the laser enable before setting the motor speed and motor stop delay.
When the laser enable is turned on, the light is stopped, and the motor stops rotating after this delay.
After the welding head light trigger is released, there will be a delay in the wire feeder to stop and
Note: The maximum delay time for stopping the wire in advance is 500MS. When the setting is
too long, please confirm that the light has been stopped before placing the welding head to
When the equipment is operating normally and when an alarm occurs, the alarm indication button is
When the equipment fails, the interface will pop up an alarm window and indicate the current
failure. At the same time, a red flashing alarm light will appear next to the alarm indication button.
After the failure is removed, the red alarm indicator will disappear. The user can click the alarm
After an alarm occurs, the user needs to immediately stop using the handheld laser welding
equipment, troubleshoot the fault, and continue to use it after the fault is resolved. Users can refer to
the alarm information in the alarm window to troubleshoot faults. The alarm information and solutions
Alarm 00: The controller is not communication line of the touch screen and
Alarm 01: Air pressure is too low Check whether the air pressure is
normal
malfunctioning
2. Power terminal: The screen uses 24V DC power supply, the terminals from right to left are:
3. RS485 communication terminal: This terminal and the controller RS485 communication
In order to improve the safety performance of the product, the handheld welding head adopts the
method of contacting light, that is, when the welding head and the welding workpiece are in contact,
the light can be emitted after pressing the light switch of the handheld welding head.
手持枪开关
+24V KA
手持枪外壳
工作台接地点
GND
Laser+ Laser-
diagram
HWS2000 LA-ON+
Dedicated display Motor-U
DB9 Communication line
Motor-V Cable Welding head
Motor-W
0-10V LA-ON-
Artifact
HWS2000
AGND Controller
GND
PWM+
Laser Source WF-V
+24V Wire
PWM- WF-EN+ Cable Feeder
WF-DIR+
GAS+
62mm