Buliquid - en
Buliquid - en
Buliquid - en
________
Industries:
Chemical
Petrochemical
Oil Exploration & Production
Pharmaceutical
Semiconductor
Food and Beverage
Water and Wastewater
Power Generation
Facilities Management
_____________
External Measurement
of Internal Flow
FLEXIM
when measuring matters
1
FLUXUS® is ...
________
Ever since its inception, FLEXIM has FLUXUS® instruments feature an ex-
been among the pioneers in the field ceptionally robust dual-μP technology
FLUXUS ® F808 - FM Class I Div I Approved
of ultrasonic flow measurement. Each core together with the latest digital
FLUXUS® embodies the wealth of ex- signal processing. They produce sta-
pertise and the application experience ble and reliable results even under the
of our engineers. most difficult application conditions.
FLEXIM rises to meet the challenges The FLUXUS® measurement algo-
where others have already failed. Put rithms automatically adapt to varying
FLEXIM’s experience and expertise to application conditions. Its very high
work for you. Submit your application measurement rate of up to 1000 mea-
to us and we will find the ideal solution! surements per second allows for a real
time statistical analysis. All this makes
the FLUXUS® unsurpassed in perfor-
mance and one of the most advanced
ultrasonic flow meters available on the
market today.
2
Flexible.
________
3
Non-intrusive.
________
100% progressive
pp Precise, hysteresis-free,
bi-directional flow measurement
with large dynamic range (turndown)
pp Long-term stability, drift-free
measurement results
pp High measuring rate
pp Quick response time Expansion & Contraction of Non Metalic Pipes
pp Measurement of even minute flows easily accommodated by FLEXIM‘s FlexSprings Mounting Design
pp High sensitivity to low flows
5
User-Friendly.
________
6
General Technical Data
* for measurement acc. to transit time difference principle, under reference conditions and at v > 0.15ft/s
** reference uncertainty < 0.2 %
Measuring principle
The Transit Time Difference Correlation Principle makes
use of the fact that the time-of-flight of an ultrasonic signal
is affected by the flow velocity of the carrier medium. Like
a swimmer working his way across a flowing river, an ul-
trasonic signal travels slower upstream than downstream.
Our instruments work according to this transit-time prin-
ciple: an ultrasonic pulse is sent downstream through the
medium, another pulse is sent upstream. By measuring
the transit time difference, the average flow velocity can be
determined. The volume flow can then be calculated out of
the flow velocity and the pipe’s dimensional parameters.
The acoustic measuring method works without inertia
and is independent of the flow direction. As a result,
FLUXUS® measures the flow bidirectionally with excellent
measurement rangeability.
7
Industry Hardened.
________
8
General Technical Data of the Transducers
Operating temperature,
extended temperature transducers: -20° F to +390 ° F
Operating temperature with WaveInjector®: from -300 ° F up to +750 ° F and beyond
9
Portable, quick and reliable.
________
With their sturdy and rugged design, they are the measu-
rement system of choice in harsh environment including
hazardous areas.
FLUXUS ® F401
Power industry
pp Measurement of boiler feed water flows
pp Monitoring of cooling circuits
10
FLUXUS ® F601/F608
11
Permanently installed,
freely configurable.
________
With the FLUXUS® ADM 5X07 and F70X series, FLEXIM offers
ultrasonic clamp-on flowmeters for permanent measuring
points. The F70X family is expressly designed towards metering
applications in industrial environments, measuring virtually any
liquid media in any environment and temperature range - even
in harsh corrosive atmospheres from as low as -310 °F up to
+750 °F and beyond. Additionally, as an Energy version it can
also measure thermal energy / BTU quantities in heating /
chiller plants and heat exchangers within the real estate sector
or any other industry. FLUXUS ® ADM 5107
Petrochemical industry
Operating temperature:
pp Measurement of basic materials
as well as intermediate and Transmitters: -4 ° F (-40 ° F ) to +140 ° F
final products Transducers: from -300 ° F to +750 ° F and beyond
pp Measurement at high temperatures, for Flow channels: 1 or 2
example tar, bitumen, quench liquids
Protection degree: F70X: NEMA 4X
Power plants (F704.316SE: FM Class I, Div. 2 approved)
pp Measurements of cooling water, ADM 5X07: NEMA 4X
boiler feed water, condensate and
heat circuits Outputs: A variety of combinations are
available from the following:
Water and wastewater industry
current (0/4 mA ... 20 mA), voltage,
pp Flow measurement on large diameter
pipes (influent, effluent, sludges) frequency, pulse, alarm
pp Consumption and distribution analysis Inputs: Maximum 4. Available are:
measurements (ADM 5X07: none) Temperature (Pt 100/1000 4-wire),
pp Measurement of underground
current, voltage
or underwater pipes
(transducers are buried)
Communication: HART, Modbus, BACnet
pp Chemical media flows
(small pipe and low flows)
13
Experts for Hazardous Areas.
________
FLUXUS® F704.316SE
and F808
With the FLUXUS® F704.316SE and F808 FLEXIM offers two FM approved flow
meters for usage in hazardous areas.
Both meters are highly corrosion resistant and thus also ideally suited for
applications offshore.
Applications
Petrochemical industry
pp Measurement of basic materials
as well as intermediate and
final products
pp Measurement of crude oil during
sampling for quality analysis
pp Measurement at
high temperatures (+750 °F),
FLUXUS ® F704.316SE e.g. ADU / VDU outlets, overflash and
sump measurement
pp Measurement of heavy gasoil
(HGO)/heavy vacuum gasoil (HVGO)
pp Measurement at cracker feeders
pp Monitoring the flow of heat
transfer oil
Chemical industry
pp Flow measurement in hazardous areas
pp Flow measurement of inorganic
and organic media (even highly corrosive
and toxic media)
FLUXUS ® F808
14
F704.316 SE and F808 for hazardous areas
Oil extraction
pp Flow measurement of crude and Operating temperature:
water at separator outlets Transmitters: F704.316SE: -40 ° F to +140° F;
pp Measurement at the wellhead F808: -4 ° F to +120 ° F
(up to 10% of gaseous volume) Transducers: from -300 ° F up to +750 ° F and beyond
pp Special low flow measurement
Flow channels: 1 or 2
of wellhead injection media
(e.g. methanol in very small doses) Hazardous Area F704.316SE: FM Class I, Div. 2
pp Flow measurement of injected Classification: F808: FM Class I, Div. 1
water
Inputs A variety of combinations are available from
pp Flow measurement of condensate
(F808 none): the following: current (0/4 mA ... 20 mA),
pp Measurement on high pressure
voltage, frequency, pulse, alarm
systems
Outputs: For F704.316SE: Maximum 4. Available are:
Natural gas extraction and
processing Temperature (Pt 100/1000 4-wire),
current, voltage
pp Measurement of injection media
(monoethylamine, For F808: Current, Binary, Frequency
triethylene glycol, etc...)
Communication: HART, ModBus
pp Measurement of reservoir water
pp Measurement of LNG
15
FLEXIM
________