Chem 140 Experiment

This laboratory report summarizes an experiment on using an analytical balance to precisely measure the mass of objects. The student measured the mass of an empty crucible, its lid, and the crucible with lid to determine the balance's accuracy. Variables like dirt, fingerprints, breathing on the crucible, and temperature changes were found to cause small changes in measured mass. Proper technique like cleaning, using draft shields, and allowing samples to cool can minimize errors and produce reliable, reproducible results when using an analytical balance.

Uploaded by

Angelie Tumamak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views6 pages

Chem 140 Experiment

This laboratory report summarizes an experiment on using an analytical balance to precisely measure the mass of objects. The student measured the mass of an empty crucible, its lid, and the crucible with lid to determine the balance's accuracy. Variables like dirt, fingerprints, breathing on the crucible, and temperature changes were found to cause small changes in measured mass. Proper technique like cleaning, using draft shields, and allowing samples to cool can minimize errors and produce reliable, reproducible results when using an analytical balance.

Uploaded by

Angelie Tumamak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 6

CHEM 140.

1 QUANTITATIVE INORGANIC CHEMISTRY (LABORATORY)


LABORATORY REPORT

Name: Date Submitted:


Lab Schedule: Date Performed:

Experiment No. 2
Introduction to the Analytical Balance

ABSTRACT:

Based at the given consequences, the consequences have been found, in figuring out the mass of an object, to have an
amazing precision and accuracy because the records have been very near every different as nicely to the “actual value”.
For instances, a few interference happened within side the real weighing and amassing of records which include lines of
dirt, dust, finger prints and air, affecting the load of the vial, mainly additionally while leaving the door of the analytical
stability open. Moreover, the ones variables have an affordable impact at the mass of an object, the customers have been
capable of be greater familiar in the usage of the analytical stability if you want to collect relative consequences and to
research strategies for which there could be much less blunders to commit.

INTRODUCTION:

Practically speaking, all measurements which shall carry out on this route relate both immediately or in a roundabout
way to a weighing the use of the unmarried pan analytical stability. The analytical stability is an essential measuring tool
for all forms of quantitative paintings in analytical chemistry. This is a sensitive and specific tool which, if stored
scrupulously smooth and dealt with correctly, will maintain to yield dependable records all through the route of its usage.

METHODOLOGY:

Determined the weight of a clean dry crucible (without lid) to within 0.1 mg. Determined the weight of the lid to within
0.1 mg. Determined the weight of the total weight of the crucible plus lid to within 0.1 mg. compare this result with the
sum of the separate weights of the crucible and lid to see how closely the weights agree. Reweigh the crucible minus the
lid to see how reproducible the weight is. Rolled the crucible around in your hand. Then reweigh and compared the weight
with the previous results. Next wiped the crucible clean with dry lint free cloth or with laboratory tissues, reweigh it and
compared the weights with the results in (3). Hold the crucible an inch from your mouth and breathed on it several times.
Reweight and compared again with (3). Placed the crucible in a drying oven for two or three minutes. Removed the
crucible from the oven with your tongs and reweigh while it’s warm. Took the weight of the crucible every 10 minutes till
it reaches balanced temperature

RESULTS AND DISCUSSION:

Results Inference
1. Part 1
a. Weight of Crucible (Initial) 21.3819g
In weighing the crucible, the analytical balance
b. Weight of Lid 11.775g must be tared.

c. Weight of Crucible + Lid 32.5595g


To get a precise and correct weight it must
d. Weight of Crucible (Reweigh) 21.3821g be that the draft shield is closed.

2. Part 2 The crucible that was rolled in the hand would add
weigh to each crucible because it undergone changes in
a. Weight of Crucible (rolled in hand) 21.3824g moisture content and moisture in hand.

b. Weight of Crucible (wiped) 21.3819g The used of laboratory tissue is to wipe the crucible and
weighed to compare the weight with the result from each
weight crucible.
The tissue paper contains fiber that would stick on the
crucible and add weight.

3. Part 3 The air coming from the mouth gave more weight
to the crucible causing it to be heavier than its
a. Weight of Crucible (breathed on) 21.3836g initial weight.

4. Part 4 When it’s hot temperature, the crucible would


weigh less, if its cold temperature, the crucible
a. Weight of Crucible (from oven) 21.3775g would weigh greater

DISCUSSION:

To use the analytical stability effectively, the analyst need to have an intensive know-how of the

construction, design, and operation of the stability. Furthermore, an appropriate use and interpretation of measurements
made with the stability is depending on the information of absolutely the precision with which samples may be weighed.
In the primary a part of this test, distinctive elements and makes use of of the analytical stability to well examine the value
of diverse not unusual place mistakes encountered turned into cautiously learned. Three crucibles with lid cowl turned
into used within side the test to estimate the character of the

distinctive mistakes made through the analytical stability. The person weight of the smooth dry crucible turned into
decided to inside 0.1 mg and turned into recorded. The weight of the lid turned into subsequent decided. Then, every
overall weight of the crucible plus lid turned into measured and in comparison with the end result of the sum of the
separate weight of crucible and lid to peer how carefully the weights agree. The crucible minus the lid turned into in my
opinion reweighed once more to peer how reproducible the burden is. Next, the crucible turned into in my opinion rolled
within side the palms and fingered. Then, reweighed and been in comparison with the weights within side the preceding
outcomes. Next, every crucible turned into wiped with a smooth laboratory tissue and reweighed to examine the weights
with the outcomes from the burden of the person crucible. Next, the person crucible turned into maintain an inch from the
mouth and turned into breathed with air for numerous instances and reweighed once more and turned into in comparison
with the outcomes from the burden of a smooth dry crucible. The crucible turned into located in a drying oven for 2 to 3
mins. After the chosen time, the crucible turned into eliminated from the oven the usage of tongs and turned into
reweighed even as it turned into nevertheless warm. The weight of the crucible for each 10 mins until it reached the
balanced temperature turned into then recorded.
. For every crucible being breathed with air, also can have an effect on the burden as it gone through modifications in
carbon dioxide which the individual respiration on it has a distinctive degree of hotness or coldness from his mouth. If it’s
a warm temperature, the crucible could weigh less, if it’s a chilly temperature, the crucible could weigh greater. Static
power that is the interplay of fees of the pattern from the encircling or the individual weighing the crucible, being due to
an imbalance of the positive (+) and negative (-) fees of the additionally provides up weight on every crucible

The crucible turned into located in the desiccator for 10 mins and in my opinion weighed and

turned into recorded. It could be very vital if you want to examine outcomes of analytical determinations done at the equal
fabric in distinctive laboratories, or at distinctive instances, possibly years apart. It is straightforward to peer how
distinctive environmental conditions (humidity), the time and form of garage practices, etc., ought to have a profound
impact on the quantity of moisture adsorbed through materials. This, in turn, could regulate the % composition, and need
to be corrected.

Errors crafted from the weighing system turned into then calculated the usage of the formula:

% Error = wt. of crucible (wipe)-reweigh x 100

Reweigh

Precision weighing with an analytical stability calls for care and application at the a part of the operator. Many elements
can have an impact on the overall performance of an analytical laboratory stability. Where precision is paramount an
blunders of 0.001 gram or smaller may be considerable while strict rules apply. In easy terms, virtual analytical stability
mistakes rise up while the tool inaccurately facts the burden of the pattern

because of impacts which can arise without the operator’s know-how, or due to negative weighing practices. Influences
may be outside or internal. Although externally precipitated mistakes may be due to many elements, they're smooth to
lessen or eliminate. Usually those reasons are traced to lapses in precision stability working processes referring to the
pattern and the laboratory surroundings. Thus, planning, checking the stability, and weighing the fabric well are the 3
simple steps on the usage of the analytical stability correctly.

CONCLUSION:

If extreme exactness isn't significant a top-stacking equilibrium will turn out only great in estimating the precision of
0.001g. Analytical equilibrium mistakes can emerge when the instrument records an erroneous load of tests inferable from
inner and outside impacts obscure to the administrator or in light of helpless gauging rehearses. While mistakes that are
actuated remotely might be a consequence of various components, they can be killed or decreased without any problem.

ACKNOWLEDGMENT:

I would like to take this opportunity to thank my chemistry teacher – , for encouraging and guiding us through this experiment
and for providing valuable suggestions. I would like to thank my parents for their generous support throughout my schooling
and wish to thank my parents as well for their undivided support and interest who inspired me and encouraged me to go my own
way, without whom I would be unable to complete my project.
GUIDE QUESTIONS AND INSTRUCTIONS:

1. Based on the weights obtained, what can you conclude about the reproducibility of results made with the balance?

Answer: Reproducibility results made with the balance shows an accurate reading which helped in the identification of
the true and nominal values of each crucible weighed on the analytical balance, the uncertainty in a single reading on the
analytical balance is ±0.0002 g. Thus, the balance used in the experiment call for accurate measurement of mass.

2. List 5 possible source of error in weighing.

Consider how these five factors can affect your system's weighing accuracy:

Answer:

 Load cell accuracy.

 Load factors.

 Environmental forces

 Interference with signal transmission.

 Instrumentation and control.

3. Name 5 tools/accessories than can help avoid error in weighing

Answer:

 A stable weighing table should be fixed to either the wall or the floor, but not both

 Place the balance away from radiators

 Use the smallest possible weighing vessel

 Always use gloves and tweezers when handling weights


4. Which is a more accurate balance? Analog or digital? Why?

Answer:

The digital it considered more accurate than manual ones. This is because digital scales are supported by technology
that allows accurate calculations, nothing more or less.

5. Discuss the difference between precision and accuracy

Answer:

Accuracy is the degree of closeness to true value. Precision is the degree to which an instrument or process
will repeat the same value.

REFERENCES:

https://www.google.com/search?q=Which+is+a+more+accurate+balance%3F+Analog+or+digital
%3F+Why%3F&sxsrf=AOaemvLOu8o5rt7_dNaqA8f5kWOFjakug
%3A1634442874707&ei=ep5rYbbWKsXywQPztZHQBQ&ved=0ahUKEwi286XxtDzAhVFeXAKHfNaBFoQ
4dUDCA4&uact=5&oq=Which+is+a+more+accurate+balance%3F+Analog+or+digital%3F+Why
%3F&gs_lcp=Cgdnd3Mtd2l6EAMyBggAEBYQHjoHCCMQ6gIQJ0oECEEYAFDGsUtYxrFLYLC7S2gCcAJ
4AIABggGIAYIBkgEDMC4xmAEAoAEBoAECsAEKwAEB&sclient=gws-wiz
.

You might also like