Formworks: Wall Footing 1 Detail

This document contains engineering plans and specifications for a reinforced concrete beam, including dimensions, reinforcement bar sizes and spacing. It has been approved by the Office of the Building Official of the Municipality of Carcar, Republic of the Philippines. The beam design calls for 12mm diameter cut-off bars and 16mm diameter continuous top and bottom bars, with 10mm diameter deformed bar stirrups and lateral ties spaced at varying intervals along the beam.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views1 page

Formworks: Wall Footing 1 Detail

This document contains engineering plans and specifications for a reinforced concrete beam, including dimensions, reinforcement bar sizes and spacing. It has been approved by the Office of the Building Official of the Municipality of Carcar, Republic of the Philippines. The beam design calls for 12mm diameter cut-off bars and 16mm diameter continuous top and bottom bars, with 10mm diameter deformed bar stirrups and lateral ties spaced at varying intervals along the beam.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

L/4 L/2 L/4 REPUBLIC OF THE PHILIPPINES

L/5 L/5

2 - 16mmØ CONT. BOTTOM BARS


OBO
1 - 12mmØ CUT-OFF BARS
1 - 12mmØ CUT-OFF BARS 2 - 16mmØ CONT. TOP BARS
OFFICE OF THE BUILDING
OFFICIAL
MUNICIPALITY OF CARCAR
10mmØ LATERAL TIES
4@50mm, 2@100mm &
REST @200mm 10mmØ DEF BAR STIRRUPS 5 SPACED @ 50mm, 5@ 100mm AND REST @ 140mm ON CENTER
4-12mmØ DEF RECOMMENDING APPROVAL:
VERTICAL BARS
0.20 0.20 0.20
HEAD:

0.30

0.30

0.30
8mmØ LATERAL TIES APPROVED BY : DATE:
4@50mm, 2@100mm &
REST @200mm ENDSPAN MID SPAN ENDSPAN
0.75

DETAIL OF 2ND FLOOR BEAM 1 BUILDING OFFICIAL: DATE:


1.00

L/4 L/2 L/4

0.60
L/5 L/5 0.43
0.25

0.120.20 0.12

0.20
2 - 12mmØ CUT-OFF BARS 2 - 16mmØ CONT. BOTTOM BARS

2 - 12mmØ CUT-OFF BARS 2 - 16mmØ CONT. TOP BARS


SECTION

0.200.10
0.30
SECTION
6-16mmØ VERTICAL 4-12mmØ VERTICAL 10mmØ DEF BAR STIRRUPS 5 SPACED @ 50mm, 5@ 100mm AND REST @ 140mm ON CENTER
BARS W/ 8mmØ BARS W/ 8mmØ
LATERAL TIES LATERAL TIES 0.20 0.20 0.20
0.43

WALL FOOTING 1 DETAIL

0.15
2" X 12" LAWA-AN TREAD

0.30

0.30

0.30
F
0.15
1.00

12-12mmØ DEF BAR


SCALE 1:30 METERS
LAYED AS SHOWN
MID SPAN
S-1 2" X 12" LAWA-AN
ENDSPAN ENDSPAN STRINGER
0.43

12-16mmØ DEF BAR


DETAIL OF 2ND FLOOR BEAM 2
LAYED AS SHOWN CONCRETE LANDING TO
PLAN 0.30 0.20 0.30
FASTEN THE STRINGER
4"thk CHB 0.25 0.25 0.25 0.25 0.25
L/4 L/2 L/4
PLAN 0.80
0.30 0.40 0.30

0.20 0.20 0.20 0.20 0.20 0.20


1.00 2 - 12mmØ CONT. BOTTOM BARS 10mmØ WALL
2 - 12mmØ CONT. TOP BARS
REINFORCEMENTS AT 0.60MOC

4-12mmØ MAIN BARS


C1-F1 C2-F2 WITH 8mmØ STIRRUPS
10mmØ DEF BAR SPACED
10mmØ DEF BAR STIRRUPS 5 SPACED @ 50mm, 5@ 100mm AND REST @ 140mm ON CENTER AT 300mm BOTH WAYS AS
D COLUMN TO FOOTING DETAIL FFL
SLAB REBARS

0.15 0.20
SCALE 1:30 METERS 0.15 0.15 0.15
S- 1

0.35
FIN. YARD LN.

0.20

0.20

0.20

0.40
ENDSPAN MID SPAN ENDSPAN 0.20
0.30
DETAIL OF ROOF BEAM

E BEAM DETAIL G WALL FOOTING 2 DETAIL H STAIR DETAIL


SCALE 1:30 METERS
S- 1 S- 1 SCALE 1:30 METERS SCALE 1:30 METERS
S- 1

A B C A B C A B C

3.50 3.50 3.50 3.50 4.00 4.00


2.10 1.40 1.40 2.10 3.15 0.85 0.85 3.15

10mmØ DEF BAR AS


BRIDGING AND
STIFFENER

1.0mmx2"x4" C-PURLINS
2.00

WF 2

SPACED AT EVERY 1M
C1 F1

C1 F1

3 WF 2 WF 2 3 2 B1 2 B1 3 RB RB
WF 2

2 B2

2 B2

2 B2
WF 1

WF 1

WF 1

WF 2
3.00

3.00
SC F2

WF 2

RB

RB

RB
SC F2

S1 S1
3.50

SC F2

2 B1 2 B1
C1 F1

C1 F1

C1 F1
S D

ED

2 2 2
6.00
AY CE

AC
6.50

6.50
W PA

S
AY
SP
TH R S

W
R
BO A

BA

TH
m B
m EF

EF
WF 1

WF 1

WF 1

BO 3.00
00 D

RB

RB

RB
m
12 mØ

3.50

0m
m
3.00

0
m

RB

RB

RB

12
10

10

WF 2 WF 2 1 RB RB

1 RB RB

1 C1 F1 C1 F1 C1 F1

A FOUNDATION PLAN B FLOOR FRAMING PLAN C ROOF FRAMING PLAN


SCALE 1:100 M SCALE 1:100 M SCALE 1:100 M
S-1 S-1 S-1

FROM THE OFFICE OF : REGISTERED ARCHITECT REGISTERED CIVIL ENGINEER: REPUBLIC ACT 545 PROJECT TITLE : APPROVED AS TO PLANS AND SPECIFICATIONS: SHEET CONTENTS DESIGNED : BELONGILOT REVISIONS : SHEET NO.

FORMWorks ENGR. JEJOMAR DUQUE


THIS DRAWING CONTAINED
HEREIN IS THE SOLE
PROPERTY OF YLAYA+RUBIA
PROPOSED: FOUNDATION PLANS

FLOOR FRAMING
DRAFTED :

DATE :
JUNIE

041808
DATE
011009
REMARKS
RE-DESIGN FLOORING
S-1
ARCHITECTS.
IT SHALL BE UNLAWFUL TO SUMMER VILLE CARCAR
REG. NO.: DATE : REG. NO. 052207 DATE : 06-28-88 REPRODUCE, COPY OR OBTAIN
BP 220 ECONOMIC HOUSING UNITS ABQ & SONS REALTY AND DEVELOPMENT CORP. ROOF FRAMING CHECKED :
DESIGN INTERIOR DESIGN CONSTRUCT ESTIMATE DRAFTING WORKS P T R NO.:
901 Q OLIVA ST., PUNTA PRINCESA, CEBU CITY TEL. NO.: 413-1112; 0917-3252292 T. I . N . :
DATE :
PLACE :
P T R NO.
T. I . N . :
071865
120-482-982
DATE : 01-07-08
PLACE : MANDAUE CITY
WITHOUT PROPER
AUTHORIZATION FROM THE
UNDERSIGNED ARCHITECTS. LOCATION : ADDRESS : RM. 204 ADVENT BUSINESS CENTER,
KAMPUTHAW, CEBU CITY