About Baldor

At Baldor Electric Company, our These products are produced at 15 • The largest stock of sub-33.7kW
mission is to be the best (as USA plants, and one in Bristol, UK. PM/shunt-w wound DC
determined by our customers) This brochure covers the wide range • 1,000+ product lines held for
marketers, designers and of products that are geared towards
manufacturers of Industrial electric rapid delivery
the European market for high quality
motors, drives and generators. industrial DC and AC motors and the • Cost-eeffective support for
From our home office in Fort Smith, majority of listed proucts are machine builders, JIT
Arkansas, we support the sales available from stock for immediate • Responsive service for urgent
offices/warehouses that stock Baldor delivery. repairs & maintenance
products worldwide, selling to
distributors and original equipment
• Warehouse system links into
manufacturers in more than 55 world manufacturing network
countries. Baldor products are • Full CE-mmarked range; all
available from 40 sales products comply with UL
offices/warehouses in North America
and 25 offices serving international
markets.

Why Baldor?
For over 80 years, Baldor has strived Energy-eefficiency leader. Industry’s shortest lead times/Flexible
to provide customers with the best We began lowering the energy manufacturing.
value and reliability in industrial consumption of our motors in the
electric motors. That dedication 1920s, long before others were even
shows in customer preference for talking about it. Today, our expansive
Baldor motors. To be considered as line of Super-E®premium-efficient
the most preferred brand in the USA. motors ranges from .75 through
1500 kW. Baldor’s Super-E®line
offers customers the highest overall
efficiency levels in the industry.

Baldor has the industry’s shortest


Baldor products are available at
lead times on custom motors – just
more locations than any other brand.
ten working days. Our unique FLEX
Our 58 globally located offices offer FLOW™ manufacturing process lets
Baldor offers the industry’s broadest immediate availability of Baldor us produce any order in any quantity,
line of stock products. products to thousands of distributors. quickly and efficiently
As a manufacturer of Industrial
Electric Motors, it is critical to be able Continuous innovation to improve Industry’s best information.
to supply the correct motor to suit reliability.
Only Baldor offers customers so
varying input Baldor leads the motor industry in many choices for product information
voltages and applying new technologies and with a wide variety of catalogues and
frequencies, as materials to improve motor reliability. product brochures, a CD-ROM
well as comply Baldor was the first to introduce electronic catalogue, the Baldor Web
with differing ISR®(Inverter Spike Resistant®) site (www.baldor.com), or you may
standards. magnet wire, which is up to 100 talk to a Baldor
Recognizing this, times more resistant to voltage customer service
Baldor has spikes. Baldor was first to use Exxon’s person at one of
developed a new Polyrex®EM grease, which our sales offices.
range of 50 Hz designed motors that protects motor bearings better,
meet IEC Standard specifications. providing improved lubrication life,
Save valuable time with just one call greater shear stability, and superior
to Baldor. We offer a large range of resistance to washout, rust and
stock motors, drives and gearboxes. corrosion.

www.baldor.com
Index
Page
DC permanent magnet and shunt wound motors - IEC and NEMA frame sizes 1

DC MOTORS
Baldor’s complete range of DC motors 15W to 550kW 2
IEC frame, permanent magnet DC motors 3
IEC frame washdown permanent magnet DC motors
4
IEC frame,DC Shunt wound motors
Tacho and mounting kits for IEC permanent magnet and shunt wound motors 5
NEMA frame, permanent magnet DC motors

DC DRIVES
6
IEC DC Motors 460/360VDC (armature/field) - 6.9kW to 1187kW
DC permanent magnet gearmotors 7
DC permanent magnet gearmotors
8
DC motor spares
Drives for DC permanent magnet motors 9

AC MOTORS
DC Drive accessories 10
AC three phase motors - IEC and NEMA frame sizes- European stock range 11
Baldor’s complete range of AC motors - US stock range 12 - 13
IEC frame, three phase AC motors 14 - 15
IEC frame, three phase AC brake motors
16
IEC frame, washdown duty AC motor range
NEMA frame, three phase AC motors 17-1
18-1
19

AC DRIVES
Large frame AC motors to 1120kW (1500 Hp)
20
Inverter and vector duty motors
Inverter duty gearmotors 21
Baldor AC industrial drives overview 22 -2
23 -2
24
Other Baldor products and information 25
IEC - quick reference chart 26
MISC.

NEMA - quick reference chart 27


Conversion tables and useful information 28- 29

Baldor has made every effort to make this catalogue complete and accurate as of the time of printing. Since products are continuously being
improved, all data is subject to change or correction. The data presented here is for general information to provide an overview of Baldor’s
capabilities. For specific applications, installation and operating instructions, certified dimensions, capabilities and performance data, and pricing
and availability, please contact your local Baldor Sales Office.
www.baldor.com
DC permanent magnet and shunt wound motors - IEC and
NEMA frame sizes
IEC metric frame motors
DC MOTORS

Baldor’s Permanent Magnet DC Motors are


available with B3 foot mount and a choice of IEC
B5 flanges for gearbox mounting in 0.15kW to
3.7kW or B14 C-faces in 0.15kW to 1.5kW. All
are designed for 180 volt input power with a 20:1
constant torque speed range.
These metric frames are protected to IP54 and are
available in both TEFC and TENV styles. Designed
for continuous duty and rated for thyristor control,
the DC motors presented here are both permanent
magnet and shunt wound types to suit a range of
DC DRIVES

applications.

NEMA general purpose motors used, these totally enclosed motors feature extensive
These Baldor motors offer the same advantages as our IEC protection for long working life in harsh conditions.
motors, but are supplied in NEMA or Imperial-size formats. DC gearmotors
This makes them ideal for use on machinery and Our extensive range of DC gearmotors covers both
automation manufactured in, or destined for, North parallel shaft and right angled models with a wide choice
America and its major export markets. of gear ratio’s and mounting styles
AC MOTORS

Washdown If you cannot find a specific motor in this catalogue, then


Baldor’s Washdown, Paint Free Washdown and Stainless please contact your local Baldor Sales Office or Distributor
Washdown are suited for applications requiring high who will be pleased to assist you.
pressure cleaning with caustic solution. These choices
allow you to select the right motor for the amount of
protection required for the specific application.
They are FDA approved making them ideal for applications
in food processing, external semi-protected environments,
or other areas where high-pressure cleaning might be

Motor selection: choosing between permanent-m


magnet and shunt wound DC types
AC DRIVES

Permanent magnet and shunt wound motors offer similar • shunt wound motors are usually preferable for
performance, but differ in ways which can make them more applications involving large and rapid changes of
suitable for particular applications, namely: current - or shock loads' - as these can demagnetise
• permanent magnet motors are, in general, slightly more permanent magnets.
economic than shunt-wound motors. • permanent magnet motors have built-in magnets; shunt
• a permanent magnetic field means that motors used in wound motors require an extra winding. This can have
metal-working environments may attract particles, an effect on physical size. It's not possible to give a
which can impair cooling and damage the motor. If general 'rule of thumb' because the way motors are put
equipment is used where iron or steel filings are present, together varies according to the rating, but if your
shunt- wound motors may be the better choice, as debris application is space-sensitive - and does not come into
MISC.

usually falls off on power-down. any of the categories above - compare the dimensions
of both types before taking a decision.
• shunt wound motor speed can be controlled using the
technique known as 'field weakening'. This is particularly
helpful for any application requiring multiple
synchronised motors, such as conveyor systems.
Note: This information is for guide purposes only. Baldor will be
pleased to offer advice on the most appropriate solution for particular
1 applications.

www.baldor.com
Baldor’s complete range of DC motors 15W to 550kW
Baldor manufactures a very wide All Baldor DC motors are covered by For full details of our complete range
range of permanent magnet and applicable UL, CSA and CE approvals of DC industrial motors and controls

DC MOTORS
wound field DC industrial motors from and a warranty you would expect from contact your local Baldor
15W to 550kW. The following a World-Class manufacturer. representative, see our 501
overview covers a selection of our full catalogue, our 501 CD-ROM or visit
range. www.baldor.com

General purpose
In addition to the stock IEC frame Most designs allow a tachometer to be
models in this catalogue, Baldor have added for closed loop applications.
an extensive range of NEMA frame 90 Applications:
or 180 VDC motors including • Conveyors • Extruders
permanent magnet designs up to
• Winders • Printing presses

DC DRIVES
3.7kW and wound field designs
through to 550kW. • Metering pumps.

Washdown
Permanent magnet DC motors are Applications:
available with a choice for standard • Conveyors • Packing equipment
painted, stainless steel and paint-free
• Food industry and other adjustable
finishes. They may be paired with our speed uses requiring high pressure
BCWD140 Washdown DC SCR hosedown
control.

AC MOTORS
Explosion proof
Permanent Magnet DC Motors are Applications:
available for 0.18kW to 1.5kW and • Conveyors and mixers in hazardous
wound field motors of 0.37kW to locations • Other adjustable speed
2.25kW for Class I, Group D and uses requiring explosion proof
Class II, Group F & G locations with motors
listing by both UL and CSA.
Power motors
Baldor Power Motors are designed for Applications:
fixed-speed operation from a • Cranes • Hoists • Conveyors

AC DRIVES
generator or battery power supply.
• Augers
These are 20% compound-wound
motors.

Integral tachometer
Baldor’s complete range of integral Applications:
tachometer motors also extends to • Precision metering • Pumps
NEMA frame motors. Its compact
• Tensioning.
design fits into many locations where
a conventional motor won’t fit.
MISC.

Lifting magnet motors


Baldor Lifting Magnet Generators Horizontal motors may be driven from
provide power for lifting electro- the diesel engine or the motors with
magnets used in scrap and bulk metal C-faces may be coupled to the PTO
handling facilities. drive of the crane.
2

www.baldor.com
IEC frame, permanent magnet DC motors
• B3 foot, B5 flange and B14 • Class F insulation • Other voltages are
face mountings available available GE DC
DC MOTORS

• 20:1 speed range with constant LTA V


• TEFC and TENV options torque VO R 24
W
• IP54 protection • 1750 or 3000 RPM versions LO 12 O
NT
• Continuous duty • Rated for thyristor drives ARIA
V

IEC frame, 180 VDC permanent magnet, B5 flange mount, B3 base

Motor Base IEC Full Shipping


Catalogue Body Body Length ‘L’
power speed Frame load Weight
No. No. style ‡ mm §
kW RPM size A kg
DC DRIVES

CK
STO
0.15 1800 D63D VP7424D† 135S TENV 1.1 ** **
0.18 1750 D71D VP3311D 3320P TENV 1.25 321 13.6 IN
0.18 1750 D71D VP3411D 3410P TEFC 1.4 330 13.6
0.25 1750 D71D VP3316D 3327P TENV 1.6 345 14.5
0.25 1750 D71D VP3416D 3413P TEFC 1.6 330 14.5
0.25 3000 D71D VP3418D 3413P TEFC 2.2 330 14.5
0.37 1750 D71D VP3326D 3336P TENV 2.5 389 14.5
0.37 1750 D71D VP3426D 3420P TEFC 2.5 397 20.4
0.37 3000 D71D VP3428D 3416P TEFC 2.5 330 16.7
0.56 1750 D80D VP3436D 3428P TEFC 3.7 397 21.8
0.56 3000 D80D VP3439D 3420P TEFC 3.6 397 20.4
0.75 1750 D80D VP3455D 3435P TEFC 5.0 419 24
AC MOTORS

0.75 3000 D80D VP3458D 3428P TEFC 5.1 397 21.8


1.1 1750 D90D VP3575D 3536P TEFC 7.7 440 34.5
B5 Flange
1.1 3000 D90D VP3468D 3432P TEFC 8.5 419 23.6
1.5 1750 D90D VP3585D 3548P TEFC 9.6 481 38
1.5 3000 D90D VP3588D 3536P TEFC 10.0 440 34.5
2.2 1750 D112D VP3603D* 3649P TEFC 14.0 643 58.5
3.7 1750 D112D VP3605D* 3681P TEFC 24.5 643 77

IEC frame, 180 VDC permanent magnet, B14 face mount, B3 base
AC DRIVES

Motor Base IEC


Catalogue Body Body
Full
Length ‘L’
Shipping CK
power speed Frame
No. No. style ‡
load
mm §
Weight STO
kW RPM size A kg IN
0.15 1800 D63C VP7424-14† 1955 TENV 1.1 ** **
0.18 1750 D71C VP3411-14 3410P TEFC 1.25 310 13.6
0.25 1750 D71C VP3416-14 3413P TEFC 1.6 310 14
0.37 1750 D71C VP3426-14 3420P TEFC 2.5 348 16.8
0.37 3000 D71C VP3428-14 3416P TEFC 2.5 330 16.7
0.56 1750 D80C VP3436-14 3428P TEFC 3.7 362 19
0.56 3000 D80C VP3439-14 3420P TEFC 3.6 348 16.8
0.75 1750 D80C VP3455-14 3435P TEFC 5.0 384 23.6
0.75 3000 D80C VP3458-14 3428P TEFC 5.1 362 19
1.1 1750 D90C VP3575-14 3435P TEFC 7.7 384 23.6
1.1 3000 D80C VP3468-14 3536P TEFC 8.5 444 33.1 B14 Face
MISC.

1.5 1750 D90C VP3585-14 3548P TEFC 9.6 475 36.7


1.5 3000 D90C VP3588-14 3536P TEFC 10 444 33.1 Note: Terminal box is shown on the
side. Standard position on top

‡ TENV/TEFC: totally enclosed non-ventilated/totally enclosed fan- * Base is non-removable


cooled ** Mechanical details available on request
§ Length and all nominal dimensions are specified against frame size Catalogue No’s with shaded cells are stocked in Europe
in IEC quick reference chart on page 26
3 † Does not conform to IP54 if base removed

www.baldor.com
IEC frame washdown permanent magnet DC motors
• B3 foot, B5 flange and B14 • Special epoxy paint gives five • Motors may be mounted in any
face mountings available times more corrosion resistance orientation

DC MOTORS
• Stainless steel shafts and • Withstands ASTM, B117 salt
hardware spray test for over 500 hours
• Corrosion resistant rotor • FDA approved
• Extra protection provides • Other voltages available
moisture resistant windings

IEC frame, 180 VDC washdown permanent magnet, TEFC

CK
Motor Base IEC Full Shipping STO
power speed Frame
Catalogue Body
load
Length ‘L’
Weight IN

DC DRIVES
No. No. mm §
kW RPM size A kg
IEC B14 face mounting
0.25 1750 D71C VPWD3416-14 3413P 1.6 330 14
0.37 1750 D71C VPWD3426-14 3420P 2.5 397 16.8
0.75 1750 D80C VPWD3455-14 3435P 5 419 19
IEC B5 flange mounting
0.25 1750 D71D VPWD3416D 3413P 1.7 330 14
0.37 1750 D71D VPWD3426D 3420P 2.25 397 16.8
0.75 1750 D80D VPWD3455D 3435P 5 419 24

These motors are identical to the B5 face- or B14 flange- Catalogue No’s with shaded cells are stocked in Europe

AC MOTORS
mounting DC permanent magnet motors described earlier with
the exception of weight, which is noted in the table.

IEC frame, DC shunt wound motors


• B3 foot, B5 flange and B14 • 20:1 speed range with constant
face mountings available torque
• IP54 protection • 1750 or 3000 RPM versions
• Continuous duty • Rated for thyristor drives
• Class F insulation

AC DRIVES
IEC frame, 180VDC Armature, 200/100 VDC field, shunt wound, TEFC

CK
Motor Base IEC
Catalogue Body
Armature Field Length Shipping
STO
power speed Frame
No. No.
full load full load ‘L’ Weight IN
kW RPM size A A mm § kg
0.18 1750 D71D VD3426D 3413D 1.3 0.25 335 11
0.25 1750 D71D VD3434D 3413D 1.9 0.25 335 11
0.37 1750 D71D VD3451D 3420D 2.6 0.25 373 13.2
0.56 1750 D80D VD3476D 3428D 3 0.3 380 16
MISC.

0.75 1750 D80D VD5318D 3535D 5 0.3 500 23.5


1.1 1750 D112D VD6215D 3636D 7.8 0.4 437 42
1.5 1750 D112D VD6202D 3646D 11 0.5 528 48
2.2 1750 D132D VD7503D 7544D 14.5 0.4 569 75

§ Length and all nominal dimensions are specified against frame size
in IEC quick reference chart on page 26
Catalogue No’s with shaded cells are stocked in Europe 4

www.baldor.com
Tacho’s and mounting kits for IEC permanent magnet and
shunt wound motors
BTG1000 series tacho’s
DC MOTORS

• Life lubricated and sealed ball bearings


• Flange or foot mounting CK
STO
• Permanent magnet fields IN
• Silver graphite brushes for long life and best
performance

This tacho may be retrofitted to Baldor permanent magnet


or shunt wound motors using the appropriate kit. The
tacho generator supplies a DC voltage that is proportional
DC DRIVES

to the motor rpm, and the polarity is changed with the


direction of rotation. This type is both suitable for
regulation within a very wide range of armature speeds,
and for 4-quadrant control. It also has the advantage of
generating a very low ripple-voltage, which results in good
regulation at low motor rpm.

BTG 1000 tacho - specification and nominal dimensions


AC MOTORS

Specification BTG1000
Voltage Gradient (V/1000rpm) 50
RMS Ripple 8%
Maximum Speed (rpm) 5000
Maximum Current (mA) 400
Armature Resistance - ohms ( at 25°C) 52
Armature Inductance (mH) 124
Armature Inertia (kg.cm2) 1.175
Maximum Terminal Voltage (VDC) 250
Reversing Error 2%
AC DRIVES

Shaft Diameter (mm) 7.94


Mounting Spigot Diameter (mm) 63.5
Mounting Holes (mm) & PCD 4 @ 101.6
Weight approx'. (kg) 2.7

BTG 1000 tacho - mounting kits

For TEFC DC motors to 5.5kW. The kit to mount the tacho generator consists of
Tacho
MISC.

a fan cover, shaft extension, and tacho adaptor bracket with miscellaneous Motor
Catalogue
hardware to connect these parts. Once the kit is in place all that is required to Body No.
No.
drive the tacho generator is a coupling between the motor shaft and tacho 33xxP TK3300
generator shaft. This coupling is supplied with the mounting kit. Use the adjacent 34xxD or P TK3400
cross reference of Motor Body No. to select the appropriate kit. 35xxD or P TK3500
36xxD TK3600
36xxP TK3600PM
Note: Catalogue No’s with shaded cells are stocked in Europe
75xx TK7500
5

www.baldor.com
NEMA frame, permanent magnet DC motors
• B3 foot and C face mountings • TEFC and TENV options • 20:1 speed range with constant
available • Continuous duty torque

DC MOTORS
• 1750 or 3450 RPM • Class F insulation • Rated for thyristor drives
• IP54 protection • 90 & 180 VDC versions

NEMA frame, 90 & 180 VDC, permanent magnet

Motor Base NEMA Voltage Full Length Shipping


Catalogue Body Body
power speed Frame load ‘C’ Weight
No. No. style ‡
kW Hp RPM
size
VDC A inch § kg CK
STO
0.05 0.06 1725 ** AP233021 30AB-0¶ TENV 180 0.4 ** ** IN
0.09 0.13 1725 ** AP7401* 74AP-0¶ TENV 90 1.3 ** **

DC DRIVES
0.09 0.13 1725 ** AP7421* 74AP-0¶ TENV 180 0.7 ** **
0.18 0.25 3450 ** AP7402* 74AP-0¶ TENV 90 2.6 ** **
0.18 0.25 3450 ** AP7422* 74AP-0¶ TENV 180 1.3 ** **
0.25 0.33 1750 56C CDP3320 3327P TENV 90 3.2 13.19 12.3
0.25 0.33 1750 56C CDP3316 3327P TENV 180 1.6 13.19 12.3
0.37 0.5 1750 56C CDP3330 3336P TENV 90 4.8 14.94 14.5
0.37 0.5 1750 56C CDP3326 3336P TENV 180 2.5 14.94 14.5
0.56 0.75 1750 56C CDP3440 3428P TEFC 90 7.0 14.59 17.3
0.56 0.75 1750 56C CDP3436 3428P TEFC 180 3.7 14.59 17.3
0.75 1.0 1750 56C CDP3445 3435P TEFC 90 10.0 15.46 20
0.75 1.0 1750 56C CDP3455 3435P TEFC 180 5.0 15.46 20
1.5 2.0 1750 145TC CDP3585 3548P TEFC 180 9.6 17.38 33.7

AC MOTORS
‡ TENV/TEFC: totally enclosed non-ventilated/totally enclosed fan- * Does not conform to IP54 if base removed
cooled ¶ Made to Imperial dimensions, but does not conform to NEMA
§ Length and all nominal dimensions are specified against frame size ** Mechanical details available on request
in NEMA quick reference chart on page 27
Catalogue No’s with shaded cells are stocked in Europe

IEC DC motors 460/360VDC (armature/field) - 6.9kW to 187kW


• Ratings to 550kW possible • Rated for continuous duty (S1) • A wide variety of options and
• Low rotor moment of inertia for • High overload capabilities special designs are available
fast response • Class ‘H’ Insulation

AC DRIVES
• Designed for full thyristor • Force ventilated
control variable speed drives
OCK
ST
Motor Nominal Current Current Shipping IN
Motor Catalogue
power speed armature field Blower Weight
frame/type No.
kW RPM A A kg
6.9 1690 B132-219 D4206 18.3 0.97 LM3 126
11.4 1761 B132-2112 D4211 28.7 1.03 LM3 166
18.5 1709 B160-2513 D4318 46.0 1.32 LM3 315
29.4 1694 B180-2810 D4429 71.7 1.95 LM4 341
33.6 1800 B180-2813 D4433 81.0 2.0 LM4 414
40.3 1613 B200-329 D4540 97.0 1.88 LM6 417
50.7 1645 B200-329 D4550 122.6 1.88 LM6 417
MISC.

74.6 1801 B200-3212 D4574 175 2.37 LM6 448


93.2# 1870 B225-368 D4693 216 2.20 LM6 487
112.0# 1810 B225-368 D46112 260 2.30 LM6 487
149.0# 1810 B225-3610 D46150 346 2.20 LM9 503
187.0# 1710 B250-4011 D46187 427 3.38 LM9 935
Motors marked with # are 4 Pole ‘Stabilised Shunt Wound’. These All motors are – IP23 – Force Ventilated IC06. All motors are foot
motors must be derated by 5% if stabilised field not connected. mounted IM1001.
Stabilised shunt motors should be connected as SHUNT ONLY when Nominal dimensions are specified against frame size in IEC quick
used with reversing controllers. reference chart on page 26 6
Other motors are 4 Pole ‘Straight Shunt Wound’.

www.baldor.com
DC permanent magnet gearmotors
• Right angle orientation with • Synthetic oil filled gearbox (oil • IP54 protection
reversible output shaft mobilith SHC634) • Continuous duty
DC MOTORS

• Foot mounting • Internal expansion bladder on • Baked Enamel Finish


• Hardened steel worm, Type BA, CB and JK gearboxes
replaceable to accommodate pressure
build-u
up
• Precision hobbed bronze gear,
replaceable • Suitable for horizontal or
vertical mounting
• Reversible

JK style, 180 VDC right angle gearmotors


DC DRIVES

CK
STO
IN

All dimensions in mm
AC MOTORS

Motor Output Max. Full


Overhung Axial
input base Gear safe Catalogue Body load Armature Inertia Weight
load load
power speed ratio torque No. No. current resistance kg cm 2 kg
kg kg
kW RPM Nm A Ω
0.09 30 58:1 13.8 GP7424 74-JK-0 0.65 29 3.17 56.8 45.4 6.3
0.09 38 45:1 12.5 GP7423 74-JK-0 0.65 29 3.17 56.8 45.4 6.3
0.15 50 45:1 13.6 GP7428 74-JK-0 1.1 21 3.17 56.8 45.4 6.3
0.09 52 33:1 8.5 GP7422 74-JK-0 0.65 29 3.17 56.8 45.4 6.3
0.18 68 45:1 15.3 GP7425 74-JK-0 1.3 11 3.17 56.8 45.4 6.3
0.18 76 45:1 11.3 GP7427 74-JK-0 1.3 8 3.17 56.8 45.4 6.3
0.09 78 22.5:1 8.1 GP7421 74-JK-0 0.65 29 3.17 56.8 45.4 6.3 Catalogue No’s with
0.18 104 33:1 8.4 GP7426 74-JK-0 1.3 8 3.17 56.8 45.4 6.3 shaded cells are
AC DRIVES

0.09 173 11:1 3.6 GP7420 74-JK-0 0.65 25 3.17 56.8 45.4 6.3 stocked in Europe

EB style, 180 VDC right angle gearmotors

CK
STO
IN
MISC.

All dimensions in mm

Motor Output Max. Full


Overhung Axial
input base Gear safe Catalogue Body load Armature Inertia Weight
load load
power speed ratio torque No. No. current resistance kg cm 2 kg Catalogue No’s with
kg kg
7 kW RPM Nm A Ω shaded cells are
0.18 20 180:1 19.8 GP7429 74-EB-0 1.0 8.3 3.17 43.2 17.2 6.8 stocked in Europe

www.baldor.com
DC permanent magnet gearmotors
• Parallel shaft gearmotors • Suits horizontal or vertical • Continuous duty
• Hardened steel helical gears, mounting • Baked Enamel Finish

DC MOTORS
replaceable • Synthetic Oil Filled Gearbox
• Diecast alloy housing & flange (Mobilith SHC007)
mount face • Reversible
• IP54 protection

Parallel shaft gearmotors, 180 VDC

CK
STO
IN

DC DRIVES
All dimensions in mm

Motor Output Max. Full


Overhung Axial
input base Gear safe Catalogue Body load Armature Inertia Weight
load load

AC MOTORS
2
power speed ratio torque No. No. current resistance kg cm kg
kg kg
kW RPM Nm A W
0.18 14 180:1 38.4 GPP7478 74-PSL-0 0.9 14 3.17 90.9 18.2 8.2
0.18 21 120:1 33.9 GPP7477 74-PSL-0 0.6 14 3.17 90.9 18.2 8.2
0.18 42 60:1 30.5 GPP7476 74-PSL-0 1.1 14 3.17 90.9 18.2 7.2
0.18 62 40:1 20.33 GPP7475 74-PSL-0 1.2 14 3.17 90.9 18.2 7.2
0.18 83 30:1 15.25 GPP7474 74-PSL-0 1.1 14 3.17 90.9 18.2 7.2
0.18 125 20:1 10.17 GPP7473 74-PSL-0 1.2 14 3.17 90.9 18.2 7.2
0.18 165 15:1 7.34 GPP7472 74-PSL-0 1.0 14 3.17 54.5 18.2 7.2
0.18 250 10:1 5.08 GPP7471 74-PSL-0 1.2 14 3.17 27.2 18.2 7.2
0.18 500 5:1 2.8 GPP7470 74-PSL-0 1.26 14 3.17 27.2 18.2 7.2
“B” Steel foot mount. B92 Bolts to bottom of PSM gearbox Catalogue No’s with
To mount PSL gearmotors. Securely mounts to gear face in 90° locations shaded cells are
“L” Type Mounting Bracket LB74 1.0
stocked in Europe

AC DRIVES
for floor, wall or ceiling mount.

DC motors - spare brushes, capacitors and spring assemblies


When calling for spare parts, please All Baldor motors in this catalogue
CK
find the part numbers you require by require one brush kit except for STO
using the table below. VD7503D which requires two. IN

Motor No. Brush kit Holder Brush caps Motor No. Brush kit Holder Brush caps
AP3021 BP5066P01SP BBR1100SP VD6202D—15D BP5001P01SP Spring assy. BP2000A01SP -
BP4530
AP7421—22 BP5052BN01SP BP4529 VD7503D BP5002A02SP Spring assy. BP2002A01SP -
MISC.

BTG1000 BP5060BD02 BP4517 BP4515 VP3311D—26D BP5011AB01SP Spring assy. BP5012A04SP -


CDP3316 BP5011AB01SP VP3411D—68D BP5000AW14SP BP5201A11SP
BP4511A01SP
CDP3320 BP5011T01SP Spring assy. VP3575D—88D BP5000T15SP BP5201A14SP
-
CDP3326 BP5011AB01SP BP5012A04SP VP3603D BP5031A01SP Spring assy. BP5030 -
CDP3330 BP5011T01SP VP3605D BP5027A01SP Spring assy. BP5028 -
CDP3411—36 BP5000AW14SP VP7424D BP5052P01 BP4529 BP4530
CDP3440—45 BP5000BK08 BP5201A11SP VPWD3426D—85D BP5000AW14SP BP5201A11SP BP4511A01SP
BP4511A01SP
CDP3455 BP5000AW14SP GPP7470—79 BP5052BN01SP BP4529 BP4530
CDP3575—85 BP5000T15SP BP5201A14SP GP233020—29 BP5060BF02SP BP4517 BP4515
VD3426D—76D BP5000H03SP BP5201A10SP BP4509A01SP GP7420—33 BP5052BN01SP BP4529 BP4530 8
VD5318D BP5000P07SP BP5201A14SP BP4511A01SP

www.baldor.com
Drives for DC permanent magnet motors
VersaFlex DC and Regen DC motor controls
DC MOTORS

• VersaFlex series 29 DC control Baldor’s VersaFlex DC controls


provides unidirectional (single combine digital motor control with CK
quadrant) digital control reliable SCR power devices to provide STO
IN
advanced motor control.
• VersaFlex series 30 Regen
On-board operator control allows
control provides bidirectional (4
easy programming of operating
quadrant) regenerative control parameters and optional feedback
• 220 to 500V line input (+/- expansion enhance drive capabilities
10%) and 50 or 60 Hz input with AC or DC tachometer or
for world-w
wide use incremental encoder feedback.
• Operator keypad is remote Controls from 35Amp to 1580Amp
DC DRIVES

mountable to 3m for optimum continuous, include built in line


ergonomic placement contactor, control logic supply and
fuses.
• Expansion boards provide
Other options include internally
connection to RS485, Modbus mounted blower, motor starter and
and Profibus-DDP networks communications boards.
• UL & cUL Versaflex DC and Regen controls can
be configured using Baldor’s windows
based program - Workbench-D.
AC MOTORS

BC 140 standalone drive & BC 142 OEM drive

• Full wave SCR control with free BC140 BC142


wheeling diode (NEMA type K)
• Field power supply allows use CK
CK STO
with shunt wound DC motors STO IN
IN
as well as permanent magnet
motors
• Adjustable accel, decel, current
limit, IR comp, min and max
AC DRIVES

speed
A ready to use single-quadrant SCR
• Current limit indicating LED drive, provided in a compact wall-or This is a variant of the BC140 drive,
• 5K speed pot for speed control panel-mounting NEMA1enclosure. provided in the form of a low-cost
• Anti-d
demag circuit protects PM The drive is optimised for motors using chassis-mounting module for OEM
motors and helps protect the the appropriate plug-in resistors (see and repair applications. It offers all
table opposite). The correct line and the circuitry features of the BC140
SCR power bridge against
armature fuses are provided with this drive above, but can control a higher
direct shorts
resistor, ensuring safe, reliable 2.25kW, 230V load when used with
• Noise rejection circuit operation. The drive may be used with an optional heatsink (ref. BC143). It
eliminates false starts and 115 or 230VAC mains for 90 or 180V also includes a built-in tacho feedback
blown SCR's DC motors, and features adjustable facility.
MISC.

• UL and cUL recognised acceleration/deceleration, MOV


transient protection, IR compensation,
• Washdown version of BC140 high-speed anti-demagnetisation, and
available from stock current limiting circuitry; the latter
function includes an indicating LED.
Approved by UL and CSA, the unit is
also fully CE compliant when operated
9 with an add-on powerline filter.

www.baldor.com
DC drive accessories
Plug-iin resistor fuse kits for BC140 and 142

DC MOTORS
Choose the resistor needed to
configure the drive by selecting the
appropriate armature voltage row for
your motor.

Motor power (kW) Required Motor Armature Line


Catalogue
Arm. voltage Arm. voltage resistor current fuse fuse
No.
90-1
130VDC 180VDC Ω A (approx'.) A (AC) A (AC)
0.007 0.015 1 - 0.5 12 BR1000
0.015 0.030 0.51 - 0.5 12 BR0510
0.025 0.050 0.35 0.33 0.5 12 BR0350
0.037 0.075 0.25 0.5 0.75 12 BR0250

DC DRIVES
0.050 0.095 0.25 0.65 1.0 12 BR0251
0.060 0.125 0.18 0.85 1.25 12 BR0180
0.125 0.18 0.1 1.3 2 12 BR0100
0.125 0.25 0.1 1.7 2.5 12 BR0101
0.18 0.37 0.05 2.5 4 12 BR0050
0.25 0.55 0.35 3.3 5 12 BR0035
0.37 0.75 0.025 5 8 12 BR0025
0.55 1.2 0.015 7.5 12*** 12 BR0015SP
0.75* 1.5* 0.01 10 15 25 BR0010SP
1.2** 2.25** 0.006 15 25*** 25 BR0006
* external heatsink required Catalogue No’s with shaded cells are stocked in Europe
** chassis mount only with external heatsink

AC MOTORS
*** also used as AC line fuse

Heatsink, powerline filter and other accessories for BC140 and BC142
Weight
Drive accessory Catalogue. No.
kg (approx'.)
for BC140/142
External heatsink (for 2.25 kW load) BC143 0.1
Fwd./brk./rev. switch BC144 0.2
Signal isolator board BC145 0.2
Current sensing relay overload protection BC146 0.2
Barrier terminal board BC147 0.1

AC DRIVES
Potentiometer kit BC148 0.1
Knob dial kit BC149 0.1
Powerline EMC filter KBRF200 0.2

Dimensions for BC140 and BC142


BC140 BC142 shown with optional BC143 heatsink
MISC.

10
Dimensions are for reference only. All dimensions in mm

www.baldor.com
AC three phase motors - IEC and NEMA frame sizes -
European stock range
Baldor produce the worlds largest range of AC three phase motors in both IEC and NEMA frame
DC MOTORS

sizes

IEC frame three phase motors IEC frame, washdown duty General purpose NEMA frame
Baldor Metric-E™ series IEC frame three phase motors three phase motors
motors are designed to IEC34/IEC72 Baldor IEC frame washdown duty Baldor's extensive line of NEMA
standards and offer outstanding motors are specifically designed for general purpose motors are available
performance and reliability with a applications where the motor is in open drip-proof and TEFC
standard totally-enclosed fan-cooled subjected to brutal, high pressure construction in both single and three
(TEFC) enclosure complying with IP55. washdown in order to maintain a phase. Power sizes available from
bacteria free operating environment. stock range from 1/12Hp to 600Hp.
DC DRIVES

For most washdown applications, the Designed for "general purpose" use
original Baldor Washdown motor, with means that these motors can be used
its durable FDA approved epoxy in applications which include
coating, is the only solution. compressors, pumps, fans, conveyors,
material handling, machine tools and
many others.
This European catalogue covers a
wide selection of motors that are
primarily aimed at European
manufacturers who export their
machines to the USA and its markets.
AC MOTORS

• Aluminium frames on sizes 63 to


112
• Cast iron frames on sizes 132
to 200
• IEC frame B5 flange, B14 face
• IEC frame B5 flange, B14 face
and B3 footmount versions
and B3 footmount versions
• Precision balance (grade N)
• Designed for food processing
• Phase insulation ensures long and other applications where
life when used with inverters. the motor is constantly exposed • Wide range of single and three
AC DRIVES

• Stocked motors comply with to an environment requiring phase NEMA frame motors
CEMEP EFF2 efficiency levels. high pressure wash down to manufactured in the USA.
• Available from stock maintain cleanliness • Most Preferred USA supplier of
• Brake motor variants are • ISR ® (Inverter Spike Resistant®) NEMA frame motors
available. 200°C magnet wire, full Class • Manufactured to EPAct
• Comprehensive options F insulation system. compliance certification
available • Double sealed bearings CC010A
lubricated with moisture • ISR® (Inverter Spike Resistant®)
resistant grease for longer life 200°C magnet wire, full Class
in wet environment F insulation system
• All stainless steel hardware to
MISC.

• Super-E E Premium Efficiency


prevent rust for longer useful (EFF1) versions available
life
• Meets UL, CSA and NEMA
• Baldor "Paint Free" or "All MG1 specifications.
Stainless" washdown motors
provide additional durability.

11

www.baldor.com
Baldor’s complete range of AC motors - US stock range
Baldor manufactures a very wide Our full range is covered by For full details of our complete range
range of single and three phase applicable UL, CSA and CE approvals of industrial motors, controls and

DC MOTORS
industrial AC motors and drives from and a warranty you would expect from generators, contact your local Baldor
0.18kW to over 2MW. The following a World-Class manufacturer. representative, see our full featured
overview covers a small selection of 501 catalogue, our 501 CD-ROM or
our full range. visit www.baldor.com

Super-E
E®- Premium Efficiency motors
Super-E Motors are designed to This means the motors in 230 and CK
conserve energy over extended time 460 volts meet NEMA's corona STO
IN
periods. These premium efficiency inception voltage requirements, and

DC DRIVES
designs are available in both Totally can withstand peak voltages of up to
Enclosed Fan Cooled and Open Drip 1600 volts. Motors having premium
Proof construction. All three phase efficiency are also available in single
motors are Inverter Ready per NEMA phase designs
Standard MG1, Part 31.4.4.2.

Severe duty and hostile environment motors


Chemical Processing motors are Typical applications include:
available from 1 Hp to 500 Hp. These • Petro-chemical plants

AC MOTORS
products are especially designed for
• Mines
those applications requiring protection
of the motors from severe • Foundries
environmental operating conditions. • Pulp and paper plants
• Waste management facilities
• Rock
• Chemical plants.

Explosion proof motors


Baldor's Explosion-proof motors are

AC DRIVES
ideal for a wide variety of applications
where hazardous fumes or dust may
be present. The motors are available
in three phase and single phase with
ratings, in stock, from 1/4 Hp to 300
Hp.

Pump motors
Our pump line of motors includes Horse powers range in size from 0.37
single or three phase jet pump motors, kW to 55kW.
MISC.

square flange motors, close-coupled Typical applications include:


pump motors, and P-Base vertical
solid shaft pump motors. The motors • Swimming pool pumps
are stocked in totally enclosed fan • Medium and high thrust in-line
cooled, open drip proof, and many • Pumps used in water treatment
explosion proof ratings. plants

12

www.baldor.com
Baldor’s complete range of AC motors - US stock range
Stainless Steel and Paint Free - Washdown duty AC motors
DC MOTORS

Baldor’s extensive range of washdown ventilated and have have excellent


duty motors extends to all stainless heat dissipation characteristics making
steel and paint free models where all them ideal for variable speed
exterior motor surfaces, shaft and applications.
hardware are totally stainless steel.
Our Paint Free range has no exterior The range is designed for:
paint and has a specially cast iron •Food processing
flange/endplate on the drive end. •Applications where the motor is
These special purpose motors include constantly exposed to an
200°C ‘ISR’ spike resistant magnet environment requiring high pressure
wire with moisture resistant class F wash down to maintain cleanliness
DC DRIVES

insulation.
All motors are totally enclosed non-

Heating, ventilating and air conditioning motors

Baldor's line of heating, ventilation, These applications include


and air conditioning motors are • Ventilators
designed with dynamically balanced • Direct drive fans
rotors for reduced vibration and quiet
AC MOTORS

• Belted fans
operation. The motors range in size • Exhaust fans
from 0.18kW to 55kW and include • Unit heaters
heavy duty industrial designs as well • Air conditioning units
as designs for commercial • Commercial refrigeration condensers
applications. • Applications involving variable
torque electronic controls used to
conserve electricity.

Commercial duty motors


The new Baldor commercial duty Typical applications include:
AC DRIVES

motor line brings Baldor's reputation • Jet pumps


for high quality designs to commercial • Heating and cooling motors
applications with a cost-effective • Ventilation motors
offering. This definite purpose product • Air conditioning motors
line is designed for certain • Blowers
applications requiring NEMA 48 and • Direct drive fans
56 motors rated between 1/4Hp to • Condenser fans
1 Hp, in both single and three phase • Pedestal fans.
ratings.
MISC.

Other Baldor motors include:

• 200V and 575V motors • Farm duty motors • F-2


2 Mounting motors
• Brake motors • Custom motors • Elevator motors

13

www.baldor.com
IEC frame, three phase AC motors
• B3 foot, B5 flange and B14 • 3 phase, 230-4 400V 50Hz /
face mountings available 277-4 480V 60HZ

DC MOTORS
• Ratings from 0.07 to 37 kW • IEC Frame sizes 63 to 200
• 2, 4, 6 and 8 pole • Efficiency class EFF2
• IP55 enclosure

Metric-E
E - 2-p
pole, 3000 RPM
Catalogue No. Nominal efficiency Power factor Torque Rotor Length
Motor F.L. Current Weight
(B3 Foot Mount—see kW Eff @ Eff @ Eff @ P.F. @ P.F. @ P.F. @ FLT POT LRT inertia ‘L’
note on page 16 for B5 type RPM 400V kgm2 mm §
kg
& B14 mount) 1/2 3/4 F.L. 1/2 3/4 F.L. Nm Nm Nm

DC DRIVES
MM50612-57 0.18 63 A2 2800 56.0 60.0 61.1 0.50 0.58 0.71 0.6 0.614 2.10 2.10 0.00016 220 3.6
MM50622-57 0.25 63 B2 2800 49.0 60.0 63.4 0.55 0.64 0.76 0.75 0.853 2.20 2.20 0.00016 220 3.9
MM50632-57 0.37 63 C2 2760 52.0 63.0 66.8 0.55 0.64 0.80 1.0 1.281 3.20 3.20 0.00020 220 4.1
MM50712-57 0.37 71 A2 2810 59.0 64.0 65.3 0.53 0.67 0.78 1.05 1.258 3.40 3.10 0.00032 253 5
MM50722-57 0.55 71 B2 2810 62.0 67.5 68.5 0.57 0.69 0.80 1.45 1.870 5.50 5.10 0.00041 253 6
MM50812-57 0.75 80 A2 2800 69.4 72.0 74.1 0.73 0.84 0.86 1.7 2.559 6.30 6.30 0.00064 282 9
MM50822-57 1.1 80 B2 2800 75.1 77.6 77.0 0.72 0.81 0.86 2.4 3.753 11.3 11.2 0.00083 282 10
MM50912-57 1.5 90 SA2 2850 78.1 80.2 78.8 0.73 0.82 0.86 3.2 5.028 12.5 11.0 0.0013 305 11.5
MM50922-57 2.2 90 LA2 2840 77.9 81.9 81.6 0.74 0.83 0.86 4.5 7.401 20.3 18.7 0.0017 330 15
MM51012-57 3 100 LA2 2860 81.4 83.0 82.8 0.66 0.77 0.84 6.2 10.02 24.0 23.3 0.0030 373 21
MM51112-57 4 112 MB2 2880 83.6 84.9 84.4 0.77 0.82 0.84 8.1 13.27 36.5 34.0 0.0051 390 31
MM51312-58 5.5 132 SA2 2890 86.0 86.0 85.8 0.72 0.82 0.86 10.8 18.18 58 51 0.0097 468 38.5
MM51322-58 7.5 132 SB2 2890 87.0 87.5 87.3 0.72 0.82 0.85 14.6 24.79 79 70 0.0126 468 44.5

AC MOTORS
MM51612-58 11 160 MA2 2920 87.0 87.3 86.5 0.91 0.93 0.94 19.5 35.99 108 108 0.0422 602 116
MM51622-58 15 160 MB2 2930 87.0 88.6 88.5 0.90 0.92 0.93 26.3 48.91 158 158 0.0422 602 116
MM51632-58 18.5 160 LA2 2930 87.2 88.8 88.7 0.90 0.92 0.93 32.4 60.32 190 190 0.0501 646 133
MM51812-58 22 180 LA2 2950 89.6 91.0 91.6 0.91 0.93 0.95 36.7 71.25 203 195 0.0855 706 186
MM52012-58 30 200 LA2 2940 89.0 91.0 89.2 0.89 0.93 0.94 52.0 97.49 285 280 0.0890 731 200
MM52022-58 37 200 LB2 2940 89.0 91.0 89.7 0.89 0.92 0.93 64.1 120.2 360 350 0.1002 731 214

Metric-E
E - 4-p
pole, 1500 RPM
Catalogue No. Nominal efficiency Power factor Torque Rotor Length
Motor F.L. Current Weight
(B3 Foot Mount—see kW Eff @ Eff @ Eff @ P.F. @ P.F. @ P.F. @ 400V FLT POT LRT inertia ‘L’
note on page 16 for B5 type RPM kgm2 mm §
kg
& B14 mount) 1/2 3/4 F.L. 1/2 3/4 F.L. Nm Nm Nm
MM50614-57 0.12 63 A4 1330 47.0 55.0 55.1 0.47 0.55 0.70 0.45 0.862 2.10 2.10 0.00018 220 3.4

AC DRIVES
MM50624-57 0.18 63 B4 1350 50.0 56.0 61.1 0.44 0.56 0.71 0.6 1.274 3.60 3.60 0.00026 220 4.1
MM50634-57 0.22 63 C4 1350 59.5 66.2 64.2 0.37 0.52 0.66 0.75 1.557 4.40 4.40 0.00030 220 4.5
MM50644-57 0.30 63 D4 1350 63.0 69.0 64.5 0.37 0.50 0.64 1.05 2.123 6.60 6.60 0.00034 220 4.8
MM50714-57 0.25 71 A4 1400 50.0 62.6 69.5 0.42 0.57 0.65 0.8 1.706 4.30 4.30 0.00066 253 5.0
MM50724-57 0.37 71 B4 1400 65.3 69.0 71.5 0.45 0.57 0.68 1.1 2.525 6.70 6.70 0.00066 253 6.0
MM50734-57 0.55 71 C4 1360 65.0 69.2 68.8 0.46 0.61 0.70 1.65 3.864 9.20 9.20 0.00081 253 7.0
MM50744-57 0.65 71 D4 1350 68.0 72.0 68.1 0.45 0.60 0.69 2.0 4.600 10.0 8.9 0.00091 253 7.5
MM50814-57 0.55 80 A4 1400 62.4 68.9 67.8 0.45 0.57 0.69 1.7 3.753 9.00 7.80 0.00101 282 9.0
MM50824-57 0.75 80 B4 1400 70.5 72.5 73.5 0.45 0.58 0.67 2.2 5.118 13.0 12.5 0.00133 282 10.0
MM50834-57 0.9 80 C4 1390 72.2 74.5 74.7 0.40 0.49 0.67 2.6 6.186 17.6 17.6 0.00149 282 11.0
MM50914-57 1.1 90 SA4 1400 75.0 77.5 76.5 0.55 0.68 0.77 2.7 7.507 18.8 17.0 0.0021 305 11.5
MM50924-57 1.5 90 LA4 1400 79.2 81.2 80.3 0.51 0.66 0.75 3.6 10.24 28.0 27.2 0.0029 330 14.0
MM50934-57 1.85 90 LB4 1400 80.1 81.0 80.7 0.52 0.66 0.77 4.3 12.63 37.5 33.5 0.0034 330 15.5
MM51014-57 2.2 100 LA4 1415 80.0 81.8 81.5 0.60 0.73 0.78 5.0 14.85 37.0 35.8 0.0047 373 19
MM51024-57 3 100 LB4 1415 81.0 83.5 83.0 0.59 0.72 0.80 6.5 20.26 62.0 57.9 0.0062 373 25
MISC.

MM51114-58 4 112 MB4 1410 86.0 86.2 84.8 0.66 0.78 0.84 8.1 27.10 73.0 70.0 0.0108 390 32
MM51314-58 5.5 132 SB4 1430 85.5 86.0 85.8 0.70 0.77 0.82 11.3 36.75 87.0 87.0 0.0213 468 44.5
MM51324-58 7.5 132 MA4 1435 86.8 87.5 87.2 0.70 0.80 0.84 14.8 49.93 125 125 0.0287 506 55
MM51614-58 11 160 MB4 1460 89.2 88.8 88.5 0.71 0.81 0.85 21.2 71.98 210 210 0.0566 602 116
MM51624-58 15 160 LA4 1460 86.8 89.3 87.5 0.74 0.83 0.87 28.5 98.16 265 265 0.0754 646 133
MM51814-58 18.5 180 LA4 1460 88.5 89.4 89.1 0.82 0.87 0.89 33.7 121.1 350 350 0.1388 706 186
MM51824-58 22 180 LB4 1460 91.3 92.0 89.5 0.71 0.80 0.85 41.8 144.0 360 360 0.1388 706 187
MM52014-58 30 200 LB4 1455 89.6 89.3 88.2 0.75 0.83 0.87 56.5 197.0 490 490 0.1623 731 214

Catalogue No’s for B3 motors with shaded cells are stocked in Europe Please check stock availability for B5 and B14 motors with your local
14
Baldor office

www.baldor.com
IEC frame, three phase AC motors
Metric-E
E - 6-p
pole, 1000 RPM
DC MOTORS

Catalogue No. Nominal efficiency Power factor Torque Rotor Length


Motor F.L. Current Weight
(B3 Foot Mount—see kW Eff @ Eff @ Eff @ P.F. @ P.F. @ P.F. @ FLT POT LRT inertia ‘L’
note below for B5 & B14 type RPM 400V kgm2 mm §
kg
mount) 1/2 3/4 F.L. 1/2 3/4 F.L. Nm Nm Nm
MM50616-57 0.09 63 C6 890 30.6 38.5 46.4 0.41 0.49 0.56 0.5 0.966 2.60 2.60 0.00030 220 4.5
MM50626-57 0.12 63 D6 870 30.0 41.0 48.2 0.36 0.46 0.60 0.6 1.318 3.10 3.10 0.00034 220 4.8
MM50716-57 0.18 71 A6 875 54.2 59.8 61.1 0.49 0.62 0.71 0.6 1.965 3.20 2.90 0.00082 253 5.5
MM50726-57 0.25 71 B6 900 58.7 64.1 63.6 0.50 0.61 0.71 0.8 2.654 4.60 4.50 0.00107 253 6.0
MM50816-57 0.37 80 A6 910 56.4 64.0 63.8 0.40 0.52 0.67 1.25 3.885 10.5 10.0 0.00197 282 9.0
MM50826-57 0.55 80 B6 900 62.6 66.4 64.9 0.45 0.59 0.68 1.8 5.839 13.2 12.8 0.00252 282 10.0
MM50916-57 0.75 90 SA6 910 66.3 69.8 69.3 0.44 0.58 0.68 2.3 7.874 16.1 16.1 0.00339 305 11.0
MM50926-57 1.1 90 LA6 910 70.1 73.3 72.1 0.42 0.56 0.68 3.2 11.55 25.9 25.9 0.00452 330 13.5
MM51016-57 1.5 100 LA6 930 76.7 78.2 77.1 0.47 0.60 0.71 3.9 15.41 35.3 35.3 0.0086 373 20.5
MM51026-57 1.85 100 LB6 920 74.4 78.2 78.0 0.42 0.57 0.68 5.0 19.21 50.0 49.4 0.0104 373 25
DC DRIVES

MM51116-58 2.2 112 MB6 945 75.1 80.3 77.4 0.63 0.72 0.79 5.2 22.24 55.0 38.0 0.0167 390 32
MM51316-58 3 132 SB6 960 81.5 83.5 83.7 0.62 0.74 0.78 6.6 29.86 91.0 75.0 0.0288 468 44.5
MM51326-58 4 132 MA6 960 81.8 83.8 84.0 0.63 0.75 0.81 8.5 39.81 110 90 0.0344 506 55
MM51336-58 5.5 132 MB6 960 82.0 84.0 83.3 0.65 0.77 0.83 11.5 54.74 133 109 0.0411 506 66
MM51616-58 7.5 160 MB6 965 86.2 86.6 86.3 0.58 0.72 0.79 15.9 74.25 210 160 0.0845 602 112
MM51626-58 9.2 160 LA6 970 88.1 89.6 89.7 0.62 0.74 0.81 18.3 90.62 270 205 0.1145 646 133
MM51636-58 11 160 LB6 970 86.7 90.0 87.8 0.60 0.72 0.80 22.7 108.3 340 270 0.1145 646 145
MM51816-58 15 180 LB6 970 85.7 89.3 87.8 0.67 0.78 0.84 29.4 147.7 460 340 0.1740 706 187
MM52016-58 18.5 200 LA6 970 85.4 85.7 85.7 0.69 0.77 0.82 38.1 182.2 520 400 0.2029 731 200
MM52026-58 22 200 LB6 965 85.9 86.0 86.0 0.70 0.79 0.85 43.5 217.8 540 420 0.2029 731 214
AC MOTORS

Metric-E
E - 8-p
pole, 750 RPM
Catalogue No. Nominal efficiency Power factor Torque Rotor Length
Motor F.L. Current Weight
(B3 Foot Mount—see kW Eff @ Eff @ Eff @ P.F. @ P.F. @ P.F. @ FLT POT LRT inertia ‘L’
note below for B5 & B14 type RPM 400V kgm2 mm §
kg
mount) 1/2 3/4 F.L. 1/2 3/4 F.L. Nm Nm Nm
MM50618-57 0.07 63 D8 650 20.5 26.0 30.0 0.46 0.51 0.62 0.55 1.029 2.50 2.50 0.00034 220 4.8
MM50718-57 0.08 71 A8 660 30.0 39.0 42.0 0.40 0.47 0.53 0.6 1.158 2.10 2.10 0.00051 253 5.5
MM50728-57 0.11 71 B8 660 30.0 37.0 40.0 0.42 0.49 0.55 0.8 1.592 2.80 2.80 0.00066 253 6
MM50818-57 0.18 80 A8 675 38.3 45.5 50.0 0.43 0.52 0.59 0.95 2.548 5.30 4.90 0.00197 282 9
MM50828-57 0.25 80 B8 675 43.0 50.0 52.0 0.41 0.51 0.62 1.25 3.539 7.00 7.00 0.00252 282 10
MM50918-57 0.37 90 SA8 680 51.0 57.4 59.4 0.38 0.49 0.60 1.5 5.199 11.6 10.6 0.00341 305 11
AC DRIVES

MM50928-57 0.55 90 LA8 690 52.0 59.0 64.5 0.37 0.46 0.56 2.2 7.616 16.0 15.8 0.00452 330 13.5
MM51018-57 0.75 100 LA8 700 62.2 67.7 68.0 0.37 0.47 0.58 2.75 10.24 20.6 20.6 0.0086 373 22
MM51028-57 1.1 100 LB8 700 60.0 66.6 65.7 0.36 0.46 0.59 4.1 15.01 40.0 38.3 0.0104 373 26
MM51118-58 1.5 112 MB8 705 66.8 69.2 73.7 0.38 0.50 0.60 4.9 20.33 55.0 40.3 0.0167 390 32
MM51318-58 2.2 132 SB8 720 69.0 76.0 78.0 0.52 0.64 0.72 5.3 29.20 72.0 58.0 0.0310 468 47
MM51328-58 3 132 MB8 720 70.0 78.0 80.0 0.53 0.65 0.72 7.3 39.80 99.0 79.0 0.0400 506 65
MM51618-58 4 160 MA8 725 76.1 81.1 83.1 0.51 0.64 0.72 9.6 52.71 150 120 0.0950 602 116
MM51628-58 5.5 160 MB8 725 77.4 83.3 83.5 0.49 0.61 0.70 13.6 72.48 210 170 0.0950 602 120
MM51638-58 7.5 160 LA8 725 77.5 83.5 83.8 0.49 0.61 0.70 18.6 98.84 290 230 0.1287 646 135
MM51818-58 11 180 LB8 730 82.3 85.4 85.2 0.50 0.62 0.72 25.9 144.0 380 280 0.2151 706 194
MM52018-58 15 200 LA8 730 83.5 85.4 85.8 0.56 0.69 0.77 32.8 196.3 460 370 0.2595 731 214

Notes for ordering B5 and B14 motors: For pricing of B5 and B14 motor types, consult your local Baldor
For B5 flange mount motor, replace first 2 letters (MM) of the office
MISC.

catalogue number with MVM and add a D before the hyphen (-)). § : Length and all nominal dimensions are specified against frame size
MM51812-58 becomes MVM51812D-58 in IEC quick reference chart on page 26
For B14 face mount motor, replace first 2 letters (MM) of the
catalogue number with MVM and add a C before the hyphen (-)).
MM50818-57 becomes MVM50818C-57
B14 face mount motors are only available up to frame size 132

15

www.baldor.com
IEC frame, three phase AC brake motors 90W...45kW
• Brake motors are available in • BM series - DC powered • Double brake models are
2, 4, 6 and 8 pole designs braking assembly available on

DC MOTORS
• B3 foot, B5 flange and B14 • Dual speed also available request
face mountings available • No axial sliding of shaft - equal
• BA series - AC powered braking braking torque in both
assembly directions

Metric-E
E brake motors - 4-p
pole, 1500 rpm
BM series - DC powered braking BA series - AC powered braking

Motor Frame Max. braking Brake reaction time Max. braking


Brake reaction time
torque (normal/quick) torque

DC DRIVES
ms
Nm ms Nm
56 2 70/30 N/A N/A
63 5 70/30 N/A N/A
71 9 80/20 14 7
80 15 80/20 18 7
90 30 80/20 38 7
100 42 80/30 50 9 Double brake motor
112 60 80/30 80 9
132 120 85/30 150 12 Specifications for Metric-E brake motors are
160 155 85/30 190 12 as our standard Metric-E motors on pages
180 180 90/30 300 12 14 and 15. For complete details contact your
200 180 90/30 300 12 Baldor representative.

AC MOTORS
Certain models available from European
stock - call for details

IEC frame, washdown duty AC motor range


• B3 foot, B5 flange and B14 • Extra protection provides • FDA approved
face mountings available moisture resistant windings EL
• Motors may be S STE
ES ,
• Stainless steel shafts and • Special epoxy paint gives five mounted in any INL ABLE
STA IL
hardware times more corrosion resistance orientation ETE AV
A
ils
L ta
• Corrosion resistant rotor • Withstands ASTM, B117 salt MP TORS de
CO O f o r
spray test for over 500 hours M allC

AC DRIVES
IEC frame, washdown duty motors
Catalogue Motor Base
Motor Voltage (50Hz)
Nominal
Weight kg CK
No. power speed
type VAC
length §
(approx'.) STO
(B3 Foot Mount—see notes
below for B5 & B14 mount) kW RPM mm IN
WDMM3538-50 0.37 1425 D71 230-400 volt 3 Phase 281 15
WDMM3546-50 0.75 1440 D80 230-400 volt 3 Phase 308 19
WDMM3554-50 1.1 1440 D90 230-400 volt 3 Phase 329 23
WDMM3558-50 1.5 1425 D90 230-400 volt 3 Phase 339 21
WDMM3611-50 2.2 1425 D100 230-400 volt 3 Phase 420 32
WDMM3615-50 4 1450 D112 400 volt 3 Phase 406 37
MISC.

WDMM3710-50 5.5 1460 D132 400 volt 3 Phase 455 58


WDMM3714-50 7.5 1450 D132 400 volt 3 Phase 484 63
B3 Foot

§ Length and all nominal dimensions are specified against frame size For B14 flange mount motor, replace the third and fourth letters (MM) of
in IEC quick reference chart on page 26 the catalogue number with MVM and add a C before the hyphen (-)).
Notes for ordering B5 and B14 motors: WDMM3538-50 becomes WDMVM3538C-50
For B5 flange mount motor, replace the third and fourth letters (MM) of the Catalogue No’s with shaded cells are stocked in Europe, B5 and B14
catalogue number with MVM and add a D before the hyphen (-)). variants are also stocked. 16
WDMM3538-50 becomes WDMVM3538D-50

www.baldor.com
NEMA frame, three phase AC motors
• B3 foot, B5 (D) flange and C • ISR® (Inverter Spike Resistant®) CK
face mountings available magnet wire, full Class F STO
DC MOTORS

IN
• Most preferred USA supplier of insulation system
NEMA frame motors • Meets UL, CSA and NEMA
• EPAct compliance certification MG1 specifications.
CC010A • IP54 protection

B3 - 2 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC


RPM Nema Dim Baldor FL Weight
Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency kg
M3457 1/3 3450 230/460 48 10.73 3410M 48 72 9.0
M3460 1/2 3450 230/460 48 12.25 3410M 48 68 8.6
DC DRIVES

M3541 3/4 3450 230/460 56 11.35 3413M 56 74 9.5


M3545 1 3450 230/460 56 11.35 3416M 56 75.5 10.5
M3550T 1.5 3450 230/460 143T 12.31 3520M 143 82.5 16.8
M3555T 2 3450 230/460 145T 13.31 3526M 145 84 19.5
M3559T 3 3460 230/460 145T 14.91 3542M 145 85.5 28.2
M3613T 5 3450 230/460 184T 16.55 3630M 184 87.5 33.2
M3616T 7 1/2 3450 230/460 184T 18.05 3640M 184 88.5 40.5
M3709T 7 1/2 3450 230/460 213T 18.56 3640M 213 88.5 42.7
M3711T 10 3500 230/460 215T 17.91 3732M 215 89.5 57.3
M3713T 15 3450 230/460 215T 20.52 3750M 215 90.2 76.4
M2394T 15 3450 230/460 254T 21.09 0750M 254 90.2 107.7
M4106T 20 3450 230/460 256T 28.01 0750M 256 90.2 118.2
AC MOTORS

M4118T 25 3510 230/460 256T 23.16 0942M 256 91 127.7


M4107T 25 3510 230/460 284TS 26.39 0942M 284 91 164.1
M4108T 30 3510 230/460 286TS 26.39 0954M 286 91 173.6
M4109T 40 3540 230/460 324TS 28.78 1240M 324 91.7 220.9
M4114T 50 3540 230/460 326TS 28.90 1244M 326 92.4 261.4
M4310T 60 3550 230/460 364TS 30.72 1450M 364 93 334.5
M4313T 75 3550 230/460 365TS 30.72 1456M 365 93 352.3
M4402T-4 100 3550 460 405TS 35.06 1652M 405 93.6 473.2
M4412T-4 125 3560 460 444TS 40.49 1860M 444 94.5 574.5
M4413T-4 150 3560 460 445TS 40.50 1856M 445 94.5 722.7
M4416T-4 200 3560 460 445TS 40.50 1876M 445 95 840.9
M44252T-4 250 3560 460 449TS 48.90 1888M 449 95.2 825.9
M44302T-4 300 3560 460 449TS 48.90 18104M 449 95 645.9
AC DRIVES

M44352T-4 350 3560 460 449TS 48.90 18148M 449 95.4 1045.5
M44402T-4 400 3545 460 449TS 48.90 18160M 449 95.8 1276.4

C Face - 2 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC


RPM Nema Dim Baldor FL Weight
Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency kg
KM3457 1/3 3450 230/460 56C 11.35 3410M 48 72 9.0
VM3537 1/2 3450 230/460 56C 11.35 3410M 48 68 8.6
VM3541 3/4 3450 230/460 56C 11.35 3413M 56 74 9.5
VM3545 1 3450 230/460 56C 11.35 3416M 56 75.5 10.5
VM3550T 1 3450 230/460 143TC 12.04 3424M 143 82.5 16.8
VM3555T 2 3450 230/460 143TC 12.92 3528M 145 84 19.5
VM3559T 3 3460 230/460 145TC 13.31 3528M 145 85.5 28.2
MISC.

VM3613T 5 3450 230/460 184TC 16.55 3628M 184 87.5 33.2


VM3616T 7 1/2 3450 230/460 184TC 18.05 3640M 184 88.5 40.5
VM3711T 10 3500 230/460 215TC 18.64 3735M 215 89.5 57.3
VM3713T 15 3450 230/460 215TC 19.77 3744M 215 90.2 76.4
VM4106T 20 3450 230/460 256TC 20.33 0750M 256 90.2 118.2
VM4107T 25 3510 230/460 284TSC 26.39 1032M 284 91 164.1
VM4108T 30 3510 230/460 286TSC 26.39 1038M 286 91 173.6

§ Dimension ‘C’ is nominal length and all other nominal dimensions Catalogue No’s with shaded cells are stocked in Europe
17 are specified against frame size in NEMA quick reference chart on
page 27

www.baldor.com
NEMA frame, three phase AC motors STO
CK
IN
B3/C Face - 2 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC

DC MOTORS
RPM Nema Dim Baldor FL Weight
Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency Kg
CM3537 1/2 3450 230/460 56C 11.35 3410M 48 68 8.6
CM3541 3/4 3450 230/460 56C 11.35 3413M 56 74 9.5
CM3545 1 3450 230/460 56C 11.35 3416M 56 75.5 10.5
CM3550T 1 3450 230/460 143TC 13.31 3520M 143 82.5 16.8
CM3555T 2 3450 230/460 145TC 13.31 3526M 145 84 19.5
CM3559T 3 3460 230/460 145TC 14.19 3542M 145 85.5 28.2
CM3613T 5 3450 230/460 184TC 16.55 3630M 184 87.5 33.2
CM3616T 7 1/2 3450 230/460 184TC 18.05 3640M 184 88.5 40.5
CM3709T 7 1/2 3450 230/460 213TC 19.28 3640M 213 88.5 42.7
CM3711T 10 3500 230/460 215TC 18.64 3732M 215 89.5 57.3
CM3713T 15 3450 230/460 215TC 21.25 3750M 215 90.2 76.4

DC DRIVES
CM4106T 20 3450 230/460 256TC 23.66 0750M 256 90.2 118.2
CM4107T 25 3510 230/460 284TSC 26.39 1036M 284 91 164.1
CM4108T 30 3510 230/460 286TSC 26.39 1040M 286 91 173.6
CM4109T 40 3540 230/460 324TSC 28.78 1234M 324 91.7 220.9
CM4114T 50 3540 230/460 326TSC 28.78 1244M 326 92.4 261.4
CM4310T 60 3550 230/460 364TSC 30.72 1444M 364 93 334.5
CM4313T 75 3550 230/460 365TSC 30.72 1456M 365 93 352.3

B3 - 4 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC


RPM Nema Dim Baldor FL Weight

AC MOTORS
Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency kg
M3353 1/8 1725 230/460 42 9.31 3313M 42 44 7.3
M3355 1/6 1725 230/460 42 9.31 3316M 42 62 7.7
M3454 1/4 1725 230/460 48 10.73 3410M 48 64 8.2
M3534 1/3 1725 230/460 56 11.35 3413M 56 68 9.5
M3538 1/2 1725 230/460 56 11.35 3416M 56 74 10.0
M3542 3/4 1725 230/460 56 11.35 3420M 56 75.5 11.8
M3546 1 1725 230/460 56 12.00 3426M 56 78.5 14.1
M3546T 1 1740 230/460 143T 12.31 3518M 143 82.5 16.4
M3554T 1 1/2 1740 230/460 145T 13.31 3524M 145 84 18.6
M3558T 2 1740 230/460 145T 13.31 3528M 145 84 20.5
M3611T 3 1750 230/460 182T 16.52 3546M 182 87.5 30.9
M3615T 5 1750 230/460 184T 16.55 3634M 184 87.5 35.9

AC DRIVES
M3710T 7 1/2 1760 230/460 213T 17.91 3735M 213 89.5 58.6
M3714T 10 1760 230/460 215T 19.03 3740M 215 89.5 63.2
M3774T 10 1760 230/460 215T 18.47 0740M 215 89.5 85.0
M2333T 15 1760 230/460 254T 23.19 0756M 254 91 110.9
M2334T 20 1760 230/460 256T 23.16 0938M 256 91 122.3
M4103T 25 1760 230/460 284T 27.76 0956M 284 92.4 180.0
M4104T 30 1760 230/460 286T 25.94 0964M 286 92.4 196.8
M4110T 40 1765 230/460 324T 30.28 1068M 324 93 235.0
M4115T 50 1760 230/460 326T 30.28 1080M 326 93 248.6
M4314T 60 1775 230/460 364T 32.84 1454M 364 93.6 339.5
M4316T 75 1775 230/460 365T 32.84 1476M 365 94.1 378.6
M4400T 100 1780 230/460 405T 38.06 1682M 405 94.5 508.2
M4410T-4 125 1780 460 444T 44.24 1868M 444 94.5 700.0
M4406T-4 150 1780 460 445T 44.24 1884M 445 95 645.9
MISC.

M4407T-4 200 1780 460 445T 44.24 18112M 445 95 755.5


M4408T-4 250 1785 460 447T 47.74 18136M 447 95 853.2
M44304T-4 300 1785 460 449T 52.65 18152M 449 95.8 1170.0
M44354T-4 350 1785 460 449T 52.65 18168M 449 95.8 1218.2
M44404T-4 400 1785 460 449T 52.65 18180M 449 95.8 1274.5

§ Dimension ‘C’ is nominal length and all other nominal dimensions Catalogue No’s with shaded cells are stocked in Europe
are specified against frame size in NEMA quick reference chart on
page 27
18

www.baldor.com
NEMA frame, three phase AC motors CK
STO
IN
C Face - 4 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC
DC MOTORS

RPM Nema Dim Baldor FL Weight


Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency kg
KM3454 1/4 1725 230/460 56C 11.35 3410M 48 64 8.2
VM3534 1/3 1725 230/460 56C 11.35 3413M 56 68 9.5
VM3538 1/2 1725 230/460 56C 11.35 3416M 56 74 10.0
VM3542 3/4 1725 230/460 56C 11.35 3420M 56 75.5 11.8
VM3546 1 1725 230/460 56C 12.00 3426M 56 78.5 14.1
VM3546T 1 1740 230/460 143TC 12.06 3426M 143 82.5 16.4
VM3554T 1 1/2 1740 230/460 145TC 12.31 3520M 145 84 18.6
VM3558T 2 1740 230/460 145TC 13.31 3528M 145 84 20.5
VM3611T 3 1750 230/460 182TC 15.18 3535M 182 87.5 30.9
VM3615T 5 1750 230/460 184TC 16.55 3634M 184 87.5 35.9
VM3710T 7 1/2 1760 230/460 213TC 18.65 3729M 213 89.5 58.6
DC DRIVES

VM3714T 10 1760 230/460 215TC 19.77 0750M 215 89.5 85.0


VM2333T 15 1760 230/460 254TC 20.33 0744M 254 91 110.9
VM2334T 20 1760 230/460 256TC 23.66 0938M 256 91 122.3
VM4103T 25 1760 230/460 284TC 27.76 1034M 284 92.4 180.0
VM4104T 30 1760 230/460 286TC 27.76 1040M 286 92.4 196.8

B3/C Face - 4 pole 3 phase 230/460V 60Hz 1.15 Service Factor TEFC
AC MOTORS

RPM Nema Dim Baldor FL Weight


Catalogue No. Hp Voltage Frame
at 60hz Frame ‘C’ § Type Efficiency kg
CM3534 1/3 1725 230/460 56C 11.35 3413M 56 68 9.5
CM3538 1/2 1725 230/460 56C 11.35 3416M 56 74 10.0
CM3542 3/4 1725 230/460 56C 11.35 3420M 56 75.5 11.8
CM3546 1 1725 230/460 56C 12.00 3426M 56 78.5 14.1
CM3546T 1 1740 230/460 143TC 13.31 3518M 143 82.5 16.4
CM3554T 1 1/2 1740 230/460 145TC 13.31 3524M 145 84 18.6
CM3558T 2 1740 230/460 145TC 13.31 3528M 145 84 20.5
CM3611T 3 1750 230/460 182TC 16.56 3546M 182 87.5 30.9
CM3615T 5 1750 230/460 184TC 16.55 3634M 184 87.5 35.9
CM3710T 7 1/2 1760 230/460 213TC 18.64 3735M 213 89.5 58.6
AC DRIVES

CM3774T 10 1760 230/460 215TC 19.24 0740M 215 89.5 85.0


CM2333T 15 1760 230/460 254TC 21.57 0756M 254 91 110.9
CM2334T 20 1760 230/460 256TC 23.66 0938M 256 91 122.3
CM4103T 25 1760 230/460 284TC 25.94 0956M 284 92.4 180.0
CM4104T 30 1760 230/460 286TC 25.94 0964M 286 92.4 196.8
CM4110T 40 1765 230/460 324TC 30.28 1248M 324 93 235.0
CM4115T 50 1760 230/460 326TC 30.28 1080M 326 93 248.6
CM4314T 60 1775 230/460 364TC 32.84 1254M 364 93.6 339.5
CM4316T 75 1775 230/460 365TC 32.84 1462M 365 94.1 378.6
CM4400T 100 1780 230/460 405TC 38.06 1682M 405 94.5 508.2

§ Dimension ‘C’ is nominal length and all other nominal dimensions Catalogue No’s with shaded cells are stocked in Europe
are specified against frame size in NEMA quick reference chart on
page 27
MISC.

19

www.baldor.com
Large frame AC motors to 1120kW (1500 Hp)
• IEC or NEMA frames • Choice of high efficiency or • Rated for inverter drives
• Ruggedised cast iron Baldor Super-E E Premium • Low loss stator and rotor design

DC MOTORS
construction Efficiency (EFF1) windings
• Service factor 1.15
• TEFC motors in stock to 375kW • ISR® (Inverter Spike Resistant®)
• If it’s not in stock, we can build
magnet wire, full Class H VPI
• Standard stock ratings are it for you on short lead times
insulation system for long life
460V and 2300/4160V

Large frame AC motors - Range overview


Voltage Voltage
Enclosure kW ratings Hp ratings
Supply 60Hz Supply 50Hz
Totally Enclosed Forced
185…670 250 - 900

DC DRIVES
Cooled
Open Drip Proof 150…1120 200 - 1500 460, 575, 950, 380, 400, 415,
2300, 3300, 950, 2300, 4160
ODP Weather Proof 1 375…1120 500 - 1500 4160 or 6600 or 6000

ODP Weather Proof 11 375…1120 500 - 1500

460, 575 380, 400, 415


Inverter/Vector 185…600 250 - 800
or 6600 or 6000

Explosion Proof 185…260 250 - 350 460 or 575 380, 400 or 415

AC MOTORS
Inverter and vector drive motors
• B3 foot and B5 flange • 3 phase, 230-4 400V 50Hz • ISR® (Inverter Spike Resistant®)
mountings available • Force ventilated magnet wire, full Class H non-
• IEC Frame sizes 80 to 250 hygroscopic insulation system
• Fitted with 1024 PPR encoder
• Ratings from 0.75 to 75 kW • Fitted with thermostats as
• 1000:1 constant torque speed standard
range

AC DRIVES
Catalogue Motor Synchronous/ Rated Inertia IEC Mounting Weight Baldor
No. kW Max. RPM A kg cm2 Frame style kg type no.
ZDNMM3581 0.75 1500/6000 1.7 72 D80-B5 D90-B3 Foot 29 0528M
ZDNMM3669 1.5 1500/6000 3.0 110 D90-B5 D112-B3 Foot 48 0628M
ZDNMM3661 2.2 1500/6000 4.7 169 D100-B5 D112-B3 Foot 53 0640M
ZDMM3665 3.7 1500/6000 7.1 156 112M B3 Foot 62 0640M
ZDMM3665D 3.7 1500/6000 7.1 156 112D B5 Flange 65 0640M
ZDMM3770 5.5 1500/6000 11.4 308 132M B3 Foot 92 0738M
ZDMM3770D 5.5 1500/6000 11.4 308 132D B5 Flange 96 0735M
ZDMM3774 7.5 1500/6000 14.4 440 132M B3 Foot 98 0750M
ZDMM3774D 7.5 1500/6000 14.4 440 132D B5 Flange 102 0750M
ZDMM2333 11.0 1500/5000 21.0 885 160M B3 Foot 127 0948M
MISC.

ZDMM2333D 11.0 1500/5000 21.0 969 160D B5 Flange 133 0948M


ZDMM2334 15.0 1500/5000 27.0 969 160L B3 Foot 141 0952M
ZDMM2334D 15.0 1500/5000 27.0 969 160D B5 Flange 142 0952M
ZDMM4103 18.5 1500/4000 33.5 1879 180M B3 Foot 187 1056M
ZDMM4104 22.5 1500/4000 41.0 1955 180L B3 Foot 216 1058M
ZDMM4110 30.0 1500/4000 53.0 3285 200L B3 Foot 250 1258M
ZDMM4115 37.0 1500/4000 67.0 4591 225S B3 Foot 306 1458M
ZDMM4314 45.0 1500/4000 78.0 4888 225M B3 Foot 362 1462M
ZDMM4316 56.0 1500/4000 101 8546 250S B3 Foot 465 1660M ZDMM motors are fitted with an encoder
ZDMM4400 75.0 1500/3000 128 11399 250M B3 Foot 537 1680M for vector drive applications 20

www.baldor.com
Inverter duty gearmotors
• Parallel shaft and right angle • ISR, inverter spike resistant
gearbox options magnet wire for increased
DC MOTORS

• Rated at 0.28 kW at 230 VAC, protection against voltage


60Hz, 3-p phase spikes and corona damage
• Operating frequency range 10 • Designed for use with inverters
- 90 Hz • UL recognised, CSA certified
• Broad range of gear ratios and CE compliant

Inverter duty gearmotors - 0.28 kW, 230 VAC, 60 Hz, 3-p


phase
Torque Torque Torque Torque
Catalogue RPM Frequency Speed
Ratio @ 10 Hz @ 20 hz @ 60 Hz @ 90 Hz Type
DC DRIVES

No. @ 60 Hz range range


Nm Nm Nm Nm
Parallel shaft
IDGMP2505 55 30 10-90 8-82 29 39 39 26 2528M-PSL
IDGMP2503 83 20 10-90 12-123 19 26 26 17 2528M-PSL
IDGMP2501 165 10 10-90 23-246 10 13 13 9 2528M-PSL
IDGMP2500 330 5 10-90 43-490 5 6 6 4 2528M-PSL
Right angle
IDGM2509 22 75 10-90 3.4-33 25 35 35 28 2528M-K
IDGM2508 28 60 10-90 4.5-41 22 28 28 26 2528M-K
IDGM2506 41 40 10-90 6.6-62 17 26 26 22 2528M-K
IDGM2503 83 20 10-90 12-123 13 15 15 13 2528M-K
AC MOTORS

IDGM2501 165 10 10-90 23-246 7 9 12 9 2528M-K


IDGM2500 330 5 10-90 43-490 4 5 8 4 2528M-K

Certain models available from European stock - call for details

2528M-PSL
AC DRIVES

All dimensions in mm - for


reference only

2528M-K
MISC.

All dimensions in mm - for


reference only
21

www.baldor.com
Baldor AC industrial drives overview
Baldor's VersaFlex range of AC drives complements our AC motor range. Available as frequency inverters, encoderless
vector and vector drive configurations, in sizes up to 410kW, VersaFlex suits many applications. All drives are fitted with

DC MOTORS
an easy to use keypad, that can also be remote mounted. The encoderless and vector drives have an optional Windows
setup tool. Fieldbus communications are available on the VersaFlex vector drives for added flexibility.
VersaFlex inverter drive - series 35
• Output frequency 0-2 240Hz with The VersaFlex inverter provides
150% overload frequency control of AC motor speed
in a form that is simple to apply. It
• 0.25-77.5kW, 198-2 264/342- comes with pre-programmed CK ils
506VAC single/three phase capability and a removable keypad for STO deta
IN for
• Process follower 0-5 5VDC, 0- setup and control. ll
Ca
10VDC, 4-2 20mA, 0-2 20mA

DC DRIVES
Choose the operating mode you want,
• Selectable pre-sset speeds and and the drive can be ready for
jog speed operation in minutes. Selectable
• Analog meter and relay output features such as torque boost or V/Hz
ratio, and skip frequencies increase
• DIN rail or panel mount versatility and extend the normal
application range.

VersaFlex encoderless vector drive - series 37


• Encoderless vector control conjunction with a versatile control
algorithm, regulates motor speed to
• Power ratings up to 112kW CK ils

AC MOTORS
precision levels. The drive can also be O
• Output frequency 0-2 240Hz with S T eta
switched to traditional V/Hz control. IN for d
150% peak overload ll
Ca
• Keypad or optional Windows Control I/O configurations and
set-u
up application macros are easily created
using the accompanying Windows
• Optional built-iin EMC filter for based tool, Workbench-D. Pre-
smaller units programmed applications such as PI
The VersaFlex encoderless vector drive control, or preset speeds can be set
provides encoderless vector control using the standard operator keypad.
for open loop induction motors.
Closed loop current control, in

AC DRIVES
VersaFlex closed loop vector drive - series 38
• Dynamic closed loop control connect VersaFlex vector drives into
factory networks. Networks include
• May be used in encoderless or DeviceNet, Modbus and Profibus. CK ils
V/Hz mode STO deta
IN for
• Power ratings up to 410kW ll
The standard I/O is enough to support Ca
• Encoder and I/O expansion many sophisticated control and user
options interfaces. This I/O complement can
be expanded with a factory installed
• Fieldbus networking options module that adds additional encoder
MISC.

• Language selectable keypad inputs, buffered encoder output, high


speed digital I/O and high resolution
analog inputs. VersaFlex is fully
VersaFlex vector drive delivers the programmable using the
ultimate in AC motor adjustable speed accompanying Windows tool,
control. A range of applications, from Workbench-D.
basic speed control, to tightly
integrated multiple-drive systems can
be easily achieved. Plug-in expansion
22
modules provide the means to

www.baldor.com
Baldor AC industrial drives overview
H - Series Inverter Drive
DC MOTORS

• NEMA 1 enclosure as standard Adjustable speed Inverter controls for


• Output frequency 0.25-1120 Hz, AC Induction motors are available in
a variety of ratings, input voltages,
optional 0.25- 400 Hz
and enclosure styles. Whether you are
• Peak overload to 200% automating equipment or preparing to
• Process follower 0-5
5 VDC, 0-1
10 save energy on fans and pumps
VDC, 4-2 20 mA Baldor has an easy to use motor
control for all your needs.
• Free run or ramp stop
From small mini inverters to floor
• Controlled reversing mounted cabinets Baldor has stock
• Selectable preset and jog ratings from 0.25 to 335kW. All units
DC DRIVES

speeds are UL and cUL listed and many are


standard with ready to mount NEMA
• Dynamic braking and DC
1 enclosures and easy to use
injection braking operator keypads.
• Analog meter outputs

SmartMotorTM
• Totally Enclosed Fan Cooled This breakthrough drive product standard and all models are
(TEFC) combines adjustable speed control available from stock. DC versions are
electronics with a Premium Efficiency also available.
AC MOTORS

• Optional set-uup and operate


industrial motor in one easy to install,
from Baldor's 32 character easy to use package. The Baldor
English-ddisplay deypad (order SmartMotor is available in 0.75 to
separately) 7.5kW covering NEMA frames from
• NEMA standard motor frames 56C to 215TC for standard and
Washdown Duty designs.
• Premium-eefficiency motor
designs Close Coupled Pump units in NEMA
143JM to 215JM frames are also
• NEMA Type 1 enclosure available. UL / cUL Listing and C-
• Dynamic braking built in Face with rigid mounting base is
DigiStart - Soft Starters
AC DRIVES

• For motor sizes 2.2 to 900kW Baldor's soft starters eliminate


downtime by removing mechanical
• 5 to 900A current rating CK ils
stress. Available in two variants, the
• Supply 230-4 460, 400-5575 and STO deta
StartMaster, a low cost unit with 10 IN for
500-6 690V pre-programmed profiles and the MD ll
Ca
• Automatic application set up series, with a keypad and English text
Fan, Pump, Conveyor etc. display.
The MD series is available with a
• Manual adjustment of Start and
remote mountable keypad that can
Stop times up to 255 seconds control up to 10 soft starters. A
• Start and Stop pedestals 10% to patented automatic energy optimiser
MISC.

60% with adjustable optimising response


• Kick start for high break away rate is available as standard.
torque applications

23

www.baldor.com
Baldor AC industrial drives overview
H - Series Vector drives

DC MOTORS
• NEMA 1 enclosure as standard High performance Vector controls for Communications protocols are
• Digital speed control or torque AC Induction motors are available in available with field installable
a variety of ratings, and input expansion boards.
control
voltages. Using Flux Vector control
• Full rated torque down to zero techniques and closed loop motor
speed feedback the Baldor Vector control
• Auto tune capability makes automating industrial
equipment easy with the built in motor
• Motor shaft orient to encoder auto-tuning feature.
marker or external switch
Baldor stocks ratings from 0.7 to 335
closure kW and has custom capabilities in

DC DRIVES
• Controlled reversing larger horsepower sizes.
• 15 preset speeds All units are UL and cUL listed and
• Dynamic braking come standard with ready to mount
NEMA 1 enclosures and easy to use
• Analog meter outputs Operator Keypads. Expansion
capabilities for various I/O and Bus

H - Series Vector line regen drives


• IGBT power devices for quiet High performance Line Regen Vector Baldor has stock range ratings from
operation controls for AC Induction motors are 7.5 to 38kW and has custom

AC MOTORS
available in a variety of ratings, input capabilities in larger power sizes.
• Digital speed or torque control
voltages, and enclosure styles. Using All units are UL and cUL listed and
• 16/32 Microprocessor Flux Vector control techniques and come standard with
controlled PWM output closed loop motor feedback the ready to mount
• Output frequency 0-5 500 Hz Baldor Line Regen Vector control adds NEMA 1 enclosures
even more capability in slowing a and easy to use
• Full rated torque down to zero motor and saving energy at the same operator keypads.
speed time.
• Auto tune capability No dynamic braking resistors are
• Motor shaft oriented to encoder needed to bleed energy from the
marker or external switch closure motor control. Near unity power factor
and ability to meet IEEE-519 (1992) is

AC DRIVES
• 15 preset speeds easy with the built in sine wave
input/output converter section.

Washdown drives
• Inverter and Vector drives built Baldor washdown duty adjustable All Washdown Duty Inverter and
to washdown standards motor controls are designed for Vector Drive Motors are UL
applications where the equipment is recognised and meet
• All the features of our powerful
subjected to brutal high-pressure NEMA MG1, Part
Inverter and Vector drives with washdown or exposed to elements of 31.
NEMA 4X enclosure as inclement weather. Inverter and Vector
MISC.

standard controls are available in NEMA 4X


• Available in standalone or built enclosures from 0.7 to10kW.
into SmartMotorTM integrated All Washdown Duty controls are UL
motor/drives and cUL Listed. Inverter and Vector
Duty motors are available in Paint Free CK ils
and Epoxy Coated finishes from 1 STO deta
IN for
to10 Hp. ll
Ca
24

www.baldor.com
EL
S STE
ES
INL LE,
E STA AILAB
LET V ils
Other Baldor products CO
MP
TOR
SA
d eta
MO for
ll
Ca
Baldor gearbox and speed reducer range
DC MOTORS

• Heavy duty cast iron housings Baldor speed reducers are available Models include double & triple
with feet cast on top and with ratings up to 20kW. Our right reduction units in foot or flange
bottom angle speed reducers feature heavy- mounted arrangements. Available in
duty cast iron construction, chill cast ratios from 1.5:1 to 250:1 and are
• Forged bronze worm gears and bronze gears, precision ground worms factory filled with Mobil® SHC634
Hardened steel worms and an internal expansion bladder Synthetic oil. A wide range of Baldor
• Ball bearing on input shaft that keeps the lubrication free of speed reducers are
• Tapered roller bearings on contaminates by eliminating the need available
to vent the gearbox. 900 Series speed from stock
output shaft
reducers are dimensionally from our
• Integral heavy duty mounting interchangeable with many other European
DC DRIVES

• Washdown and stainless steel worm gear speed reducers and are based
version available factory filled with Mobil® SHC634 warehouses.
Synthetic oil.
Baldor also offers our 1000 Series in- CK
line heavy-duty helical gear drives. STO
IN

Baldor generators
Baldor manufacture a wide range of generator sets to the state-of-the-art 8-25 kW ratings, these units
power generators for a wealth of electronics and controls, these units continuously monitor the electrical
power supply applications. The are suited for all commercial, current in your home or office and
AC MOTORS

following is a brief overview, for more industrial and rental applications. start up automatically if the utility
information visit www.baldor.com or Available from 25KVA/20kW to power is interrupted.
contact your local Baldor 175KVA/140kW.
representative.
Industrial Standby / Prime Power
Baldor IDLC generators are at work all
Industrial Portables over the globe. For peak shaving duty,
Baldor portable generators are IDLC generators can supply prime
suitable for applications where power in parallel with the utility. In the
portable power is needed. Available standby mode, the IDLC gensets can
from 1300 to11,000 watts these supply emergency power to all critical
generators are designed for loads and selected loads as desired.
continuous operations. Portable Every IDLC power system is designed,
AC DRIVES

generators are available in four engineered, built and tested to the


models: full featured (Premier line); customer's specific specifications.
maximum value (Powerchief line); Baldor's IDLC diesel generator sets
multi-fuel and diesel. Open Industrial Standby include ratings from 30kW to
Industrial diesel engine-driven 2000kW.
generator systems for industrial
applications including agricultural
confinement house operations,
greenhouse facilities and dairy
operations. Used also as power
systems for Municipality services such
as water treatment plants and
emergency centres. Available in sizes
MISC.

30kW to 150kW.

Automatic Emergency Standby


Industrial Towable Standby
The Automatic Emergency (AE)
Baldor’s switchable/towable diesel generators have been engineered and
generators are engineered for built to meet the emergency power
superior reliability, versatility, durability needs of the residential and light
25 and safety. From the ultra quiet sound commercial customer. Available from
attenuated enclosures and precision
www.baldor.com
IEC - quick reference chart
IEC Key and Keyseat dimensions

DC MOTORS
FRAME D G F GD FRAME D G F GD
63 11 8.5 4 4 160 37 42 12 8
71 14 11 5 5 180 48 42.5 14 9
80 19 15.5 6 6 200 55 49 16 10
90 24 20 8 7 225 60 53 18 11
100 28 24 8 7 250 70 67.5 20 12
112 28 24 8 7 280 80 71 22 14
132 38 33 10 8 315 85 76 22 14
B14 Face 355 85 76 22 14

DC DRIVES
B5 Flange B3 Foot

IEC Foot mounting Shaft B5 flange B14 face General


Type
Frame A B C H D E LA M N P S T M N P S T L AC AD HC XX

AC MOTORS
102 121 13
63 300 100 80 40 63 11 23 8 115 95 140 9 3 75 60 90 M5 2.5 * 119
116d 136d 22d
300 119 131 18
71 112 90 45 71 14 30 8 130 110 160 10 3.5 85 70 105 M6 2.5 * 102
400 145d 149d 21d
400 145 116 152 22
80 125 100 50 80 19 40 13 165 130 200 11 3.5 100 80 120 M6 3 *
500 168d 130d 162d 21d
S 100 168 130 173 22
90 140 56 90 24 50 13 165 130 200 12 3.5 115 95 140 M8 3 *
L 125 144d 107d 165d 21d
S 112 149 180
100 160 63 100 28 60 14 215 180 250 14 4 130 110 160 M8 3.5 * 200 27
L 140 153d 239d
S 114
112 190 70 112 28 60 14 215 180 250 14 4 130 110 160 M8 3.5 * 200 149 214 27
M 140
S 140
132 216 89 132 38 80 14 265 230 300 14 4 165 130 200 M8 3.5 * 243 187 256 27
M 178
M 210
160 254 108 160 42 110 20 300 250 350 19 5 215 180 250 M12 4 * 329 242 329 35
L 254
M 241
180 279 121 180 48 110 20 300 250 350 19 5 * 395 333 372 51
L 279
L 267
200 318 133 200 55 110 27 350 300 400 19 5 * 441 359 416 63
M 305
S 286
225 356 149 225 60 140 19 400 350 450 19 6 * 495 383 483 63
M 311
S 311
250 406 168 250 70 140 * 520 457 513 63
M 349
S 368
280 457 190 280 80 170 * 616 497 581 63

AC DRIVES
M 419
S 406
315 508 216 315 85 170 * 759 683 682 102
M 457
S 500
355 610 254 355 85 170 * 759 683 719 102
L 630

Horizontal shaft arrangements Summary of IP protection numbers


First number Protection Second number Protection
IP Protection against solid objects against liquids
Baldor Enclosures
O NO PROTECTION O NO PROTECTION

Open Drip
Protection against solid objects up to 50 Protection against vertical drops of water.
B3 B5 B6 B7 B8 B14 IP22 Proof AC or 1 mm. (E.G. Accidental touch by hands.) 1 (E.G. Condensation.)

FOOT MOUNTED. "D" TYPE FLANGE FOOT WALL FOOT WALL CEILING "C" TYPE FACE AT DC Motors
AT DRIVE END, NO MOUNT WITH MOUNT WITH MOUNTED WITH DRIVE END, NO Protection against solid objects up to12 Protection against falling water up to 15
FEET. FEET ON LEFT FEET ON RIGHT FEET ABOVE FEET. 2 mm. (E.G. Fingers) 2 degrees from the vertical.
HAND SIDE WHEN HAND SIDE WHEN MOTOR. All standard
VIEWED FROM VIEWED FROM
DRIVE END. DRIVE END.
IP54 TEFC AC and Protection against solid objects over 2.5 Protection against falling water up to 60
DC Motors 3 mm. (E.G. Tools, Wires]) 3 degrees from the vertical.
Vertical shaft arrangements
Protection against solid objects over 1 mm. Protection against splashing water from all
All TEFC 4 4
MISC.

(E.G. Tools, Wires, and Small Wires) directions, limited ingress.


Chemical
Processing, 5 Protection against dust - limited ingress
5 Protection against low pressure jets of water
(No harmful deposits) from all directions, limited ingress.
IP55 Dirty Duty,
V1 V3 V5 V6 V18 V19 and Protection against strong jets of water. (E.G.
Washdown 6 Totally protected against all dust. 6 Use on shipdecks, limited ingress.)
"D" TYPE FLANGE "D" TYPE FLANGE VERTICAL FOOT, VERTICAL FOOT, "C" TYPE FACE AT "C" TYPE FACE AT
AT DRIVE END , AT DRIVE END, WALL MOUNTED, WALL MOUNTED, DRIVE END, SHAFT DRIVE END, SHAFT Duty Motors
SHAFT DOWN, NO SHAFT UP, NO SHAFT DOWN. SHAFT UP DOWN, NO FEET UP, NO FEET. 7 Protection against immersion.
FEET. FEET.
8 Protection against submersion.

Drawings represent standard TEFC general purpose motors ‘L’ dimension - see IEC motor sections in this catalogue for
*Dimensions are for reference only. All dimensions in mm these dimensions or contact your local Baldor sales office 26

www.baldor.com
NEMA - quick reference chart

NEMA Keyseat details


DC MOTORS

Shaft Keyseat Shaft Keyseat


diameter dimensions diameter dimensions
U R S U R S
3/8 21/64 FLAT 1-7/8 1-19/32 1/2
1/2 29/64 FLAT 2-1/8 1-27/32 1/2
5/8 33/64 3/16 2-3/8 2-1/64 5/8
7/8 49/64 3/16 2-1/2 2-3/16 5/8
1-1/8 63/64 1/4 2-7/8 2-29/64 3/4
1-3/8 1-13/64 5/16 3-3/8 2-7/8 7/8
1-5/8 1-13/32 3/8 3-7/8 3-5/16 1
DC DRIVES

NEMA C-F
Face, BA dimensions
NEMA Frame BA
143-5TC 2-3/4
182-4TC 3-1/2
213-5TC 4-1/4
254-6TC 4-3/4

NEMA
D E 2F H N O P U V AA AB AH AJ AK BA BB BD XO TAP
frame
AC MOTORS

9/32
42 2-5/8 1-3/4 1-11/16 1-1/2 5 4-11/16 3/8 1-1/8 3/8 4-1/32 1-5/16 3-3/4 3 2-1/16 1/8 4-5/8 1-9/16 1/4-20
SLOT
11/32
48 3 2-1/8 2-3/4 1-7/8 5-7/8 5-11/16 1/2 1-1/2 1/2 4-3/8 1-11/16 3-3/4 3 2-1/2 1/8 5-5/8 2-1/4 1/4-20
SLOT
56 3 11/32 2-7/16
3-1/2 2-7/16 6-7/8 6-5/8 5/8 1-7/8 1/2 5 2-1/16 5-7/8 4-1/2 2-3/4 1/8 6-1/2 2-1/4 3/8-16
56H 5 SLOT 2-1/8
143T 4
3-1/2 2-3/4 11/32 2-1/2 6-7/8 6-5/8 7/8 2-1/4 3/4 5-1/4 2-1/8 5-7/8 4-1/2 2-1/4 1/8 6-1/2 2-1/4 3/8-16
145T 5
182 4-1/2 2-11/16 2-1/4 2-1/8 5-7/8 4-1/2 1/8 6-1/2 3/8-16
184 5-1/2 2-11/16 2-1/4 2-1/8 5-7/8 4-1/2 1/8 6-1/2 3/8-16
4-1/2 3-3/4 13/32 8-11/16 7-7/8 7/8 3/4 5-7/8 2-3/4 2-3/8
182T 4-1/2 3-9/16 2-3/4 2-5/8 7-1/4 8-1/2 1/4 9 1/2-13
184T 5-1/2 3-9/16 2-3/4 2-5/8 7-1/4 8-1/2 1/4 9 1/2-13
215 5-1/2 3-1/2 1-1/8 3 2-3/4
213 7 3-1/2 1-1/8 3 2-3/4
5-1/4 4-1/4 13/32 10-1/4 9-9/16 3/4 7-3/8 7-1/4 8-1/2 3-1/2 1/4 9 2-3/4 1/2-13
213T 5-1/2 3-7/8 1-3/8 3-3/8 3-1/8
215T 7 3-7/8 1-3/8 3-3/8 3-1/8
254U 8-1/4 4-1/16 1-3/8 3-3/4 3-1/2
256U 10 4-1/16 1-3/8 3-3/4 3-1/2
6-1/4 5 17/32 12-7/8 12-15/16 1 9-5/8 7-1/4 8-1/2 4-1/4 1/4 10 --- 1/2-13
254T 8-1/4 4-5/16 1-5/8 4 3-3/4
256T 10 4-5/16 1-5/8 4 3-3/4
284U 9-1/2 1-5/8 4-7/8 4-5/8
AC DRIVES

286U 11 1-5/8 4-7/8 4-5/8


284T 9-1/2 1-7/8 4-5/8 4-3/8
7 5-1/2 17/32 5-1/8 14-5/8 14-5/8 1-1/2 13-1/8 9 10-1/2 4-3/4 1/4 11-1/4 --- 1/2-13
286T 11 1-7/8 4-5/8 4-3/8
284TS 9-1/2 1-5/8 3-1/4 3
286TS 11 1-5/8 3-1/4 3
324U 10-1/2 5-7/8 1-7/8 5-5/8 5-3/8
326U 12 5-7/8 1-7/8 5-5/8 5-3/8
324T 10-1/2 5-1/2 2-1/8 5-1/4 5
8 6-1/4 21/32 16-1/2 16-1/2 2 14-1/8 11 12-1/2 5-1/4 1/4 13-3/8 --- 5/8-11
326T 12 5-1/2 2-1/8 5-1/4 5
324TS 10-1/2 3-15/16 1-7/8 3-3/4 3-1/2
326TS 12 3-15/16 1-7/8 3-3/4 3-1/2
364U 11-1/4 6-3/4 2-1/8 6-3/8 6-1/8
365U 12-1/4 6-3/4 2-1/8 6-3/8 6-1/8
364T 11-1/4 6-1/4 2-3/8 5-7/8 5-5/8
9 7 21/32 18-1/2 18-1/4 2-1/2 15-1/16 11 12-1/2 5-7/8 1/4 13-3/8 --- 5/8-11
365T 12-1/4 6-1/4 2-3/8 5-7/8 5-5/8
364TS 11-1/4 4 1-7/8 3-3/4 3-1/2
365TS 12-1/4 4 1-7/8 3-3/4 3-1/2
404U 12-1/4 7-3/16 2-3/8 6-7/8
405U 13-3/4 7-3/16 2-3/8 6-7/8
404T 12-1/4 7-5/16 2-7/8 7
10 8 13/16 20-5/16 20-1/8 7-1/4 3 18 11 12-1/2 6-5/8 1/4 13-7/8 --- 5/8-11
405T 13-3/4 7-5/16 2-7/8 7
404TS 12-1/4 4-1/2 2-1/8 4
405TS 13-3/4 4-1/2 2-1/8 4
MISC.

444U 14-1/2 8-5/8 22-7/8 22-3/8 2-7/8 8-5/8 19-9/16 8-3/8


445U 16-1/2 8-5/8 22-7/8 22-3/8 2-7/8 8-5/8 19-9/16 8-3/8
444T 14-1/2 8-1/2 22-7/8 22-3/8 3-3/8 8-1/2 19-9/16 8-1/4
445T 16-1/2 8-1/2 22-7/8 22-3/8 3-3/8 8-1/2 19-9/16 8-1/4
447T 20 8-15/16 22-15/16 23-3/4 3-3/8 8-1/2 21-11/16 8-1/4
11 9 13/16 3 14 16 7-1/2 1/4 16-3/4 --- 5/8-11
449T 25 8-15/16 22-15/16 23-3/4 3-3/8 8-1/2 21-11/16 8-1/4
444TS 14-1/2 5-3/16 22-7/8 22-3/8 2-3/8 4-3/4 19-9/16 4-1/2
445TS 16-1/2 5-3/16 22-7/8 22-3/8 2-3/8 4-3/4 19-9/16 4-1/2
447TS 20 4-15/16 22-15/16 23-3/4 2-3/8 4-3/4 21-11/16 4-1/2
449TS 25 4-15/16 22-15/16 23-3/4 2-3/8 4-3/4 21-11/16 4-1/2

Drawings represent standard TEFC general purpose motors for these dimensions or contact your local Baldor sales office
*Dimensions are for reference only. Dimensions N, O, P, AB AND XO are specific to Baldor.
27 ‘C’ dimension - See relevant NEMA sections of this catalogue All dimensions are in inches.

www.baldor.com
Conversion tables and useful information
To convert from A to B, multiply by value in table

DC MOTORS
Rotary inertia

A B gm-ccm2 oz-iin2 gm-ccm-ss2 kg-ccm2 lb-iin2 oz-iin-ss2 lb-fft2 Kg-ccm-ss2 lb-iin-ss2


-7
g-ccm 2
1 5.46x10 1.01x10 -3
10-3 3.417x10- -3 4
1.41x10 -5
2.37x10 1.01x10
-6 -6
8.85x10
oz-iin2 182.9 1 0.186 0.182 0.0625 2.59x10-3 4.34x10-4 1.86x10-4 1.61x10-4
g-ccm-ss2 980.6 5.36 1 0.9806 0.335 1.38x10-2 2.32x10-3 10-3 8.67x10-4
kg-ccm2 1000 5.46 1.019 1 0.3417 1.41x10-2 2.37x10-3 1.019x10-3 8.85x10-4
lb-iin2 2.92x103 16 2.984 2.926 1 4.14x10-2 6.94x10-3 2.98x10-3 2.59x10-3
oz-iin-ss2 7.06x104 386.08 72 70.615 24.13 1 0.1675 7.20x10-2 6.25x10-2
lb-fft2 4.21x105 2304 429.71 421.40 144 5.967 1 0.4297 0.3729
kg-ccm-ss2 9.8x105 5.36x103 1000 980.66 335.1 13.887 2.327 1 0.8679

DC DRIVES
lb-iin-ss2 1.129x106 6.177x103 1.152x103 1.129x103 386.08 16 2.681 1.152 1

Torque Power

A B oz-iin kg-ccm lb-iin Nm lb-fft kg-m


m B Watts Kilowatts ft.lb/sec in-llb/sec Hp
A
oz-iin 1 7.200x10 -2
6.25x10 -2
7.061x10 5.208x10 7.200x10-4
-3 -3
Watts (W) 1 1 x 10-3 0.74 8.85 1.34 x 10-3
kg-ccm 13.877 1 0.8679 9.806X10-2 7.233X10-2 10-2 Kilowatts (kW) 1000 1 738 8850 1.34
lb-iin 16 1.152 1 0.112 8.333x10-2 1.152x10-2 ft-llb/sec 1.35 1.36 x 10-3 1 12 1.82 x 10-3
Nm 141.612 10.197 8.850 1 0.737 0.101 in-llb/sec 0.113 1.13 x 10-4 8.3 x 10-2 1 1.52 x 10-4
lb-fft 192 13.825 12 1.355 1 0.138 Hp 746 0.746 550 6600 1
kg-mm 1.388x103 100 86.796 9.806 7.233 1

AC MOTORS
Length Mass
BInch Feet Micron Millimetre Metre
A ( in ) ( ft ) (µm) (mm) m A B oz-m
m lb-m
m gm kg
-2
Inch ( in ) 1 8.33 x 10 2.54 x 10
-2 4
25.4 2.54 x 10-2 oz-m
m 1 6.25 x 10 28.35 2.835 x 10-2
Feet ( ft ) 12 1 3.05 x 105 305 0.305 lb-m
m 16 1 453.6 0.453
-2
Micron (µm) 3.937 x 10-5 3.28 x 10-6 1 0.001 1.0 x 10-6 gm 3.53 x 10 2.205 x 10-3 1 0.001
Millimetre (mm) 3.937 x 10-2 3.28 x 10-3 1000 1 0.001 kg 35.274 2.205 1000 1
Metre (m) 39.37 3.28 1 x 106 1000 1

Force

AC DRIVES
A B oz-ff lb-ff Newtons gm-ff Kg-ff
-2
oz-ff 1 6.25 x 10 0.278 28.35 2.835 x 10-2
lb-ff 16 1 4.448 453.6 0.4535
Newtons 3.596 0.225 1 101.9 0.1019
gm-ff 3.53 x 10-2 2.205 x 10-3 9.81 x 10-3 1 0.001
kg-ff 35.3 2.205 9.81 1000 1

Linear speed

A B in/sec ft/sec mm/sec m/sec inch/min ft/min m/min km/hour miles/hour


MISC.

in/sec 1 0.083 25.4 2.54 x 10 -2


60 5 1.524 0.091 5.7 x 10-2
ft/sec 12 1 304.8 0.3048 720 60 18.29 1.09 0.682
mm/sec 3.937 x 10-2 3.3 x 10-3 1 0.001 2.36 0.197 0.059 3.6 x 10-3 2.24 x 10-3
m/sec 39.37 3.281 1000 1 2362.2 197 60 3.6 2.24
inch/min 0.0167 1.39 x 10-3 0.42 4.2 x 10-4 1 8.33 x 10-2 2.54 x 10-2 1.52 x 10-3 9.5 x 10-4
ft/min 0.2 0.0167 5.08 5.08 x 10-3 12 1 0.3048 1.8 x 10-2 1.14 x 10-2
m/min 0.656 5.46 x 10-2 16.667 1.67 x 10-2 39.4 3.28 1 5.9 x 10-2 0.37
km/hour 10.936 0.911 277.8 0.2778 656 54.67 16.67 1 0.62
miles/hour 17.59 1.47 447 0.447 1056 88 26.8 1.609 1
28

www.baldor.com
Conversion tables and useful information
Material Densities ( D) Mechanism Efficiencies %
DC MOTORS

Acme Screw (Bronze Nut) 40-6


65
oz/in 3 lb/in 3 gm/cm 3
Acme Screw (Plastic Nut) 50-8
85
Aluminum 1.57 0.098 2.72
Ball Screw 90-9
95
Brass 4.96 0.31 8.6
Helical Gear 96-9
98
Bronze 4.72 0.295 8.17
Spur Gear 90
Copper 5.15 0.322 8.91
Timing Belt/Pulley 90-9
97
Plastic 0.64 0.04 1.11
Worm Gears 60-8
85
Steel 4.48 0.28 7.75

Friction Coefficients (sliding) Temperature


Steel on Steel 0.58 ºF = (1.8x ºC) + 32
DC DRIVES

Steel on Steel (Greased) 0.15 ºC = .555 (ºF - 32)


Aluminum on Steel 0.45
Copper on Steel 0.36
Brass on Steel 0.40 Gravity (Acceleration Constant)
Plastic on Steel 0.20
Linear Bearings 0.001 g = 386 in/s2 = 32.2 ft/s2 = 9.8 m/s2

Calculating power requirements - P

Rotational Lifting
AC MOTORS

P (kW) = T(Nm) x n (rpm) P (kW) = M(kg) x V (m/s)


9549
102

P (Hp) = T(lb ft) x n (rpm) P (Hp) = M(lb) x V (ft/s)


5252 550

Linear
AC DRIVES

Calculating torque to accelerate in given time


P (kW) = F(N) x V (m/s)
1000 T (Nm) = J(kgm2) x N (rpm)
9.549 x t (s)
P (Hp) = F(lbf) x V (ft/s)
550

Calculating Inertia Units

M = TTDt x (D20 - D2I ) DO, DI, t, in metres m


4 3 3
MISC.

D in Kilograms / metre kgm


J = Mr = TTDt x (D04 - D4I )
2

32 M in Kilograms kg
2 2

J = Mr = M x (D20 + D2I )
2
J = Kilograms /metre kgm
8

29

www.baldor.com
Notes

30

www.baldor.com
Notes

31

www.baldor.com
Visit www.baldor.com to request copies of these catalogues:

Chemical Process Industrial Motor Tachogenerators


Motors for IEEE 841 Replacement Parts BR 602
FL 420 CA 506

Stock Product Catalogue


BR 501

Metric-E Motors Total Power Solutions Motion Control Products


BR 2405 Catalogue
IBR 310
BR 1202

Large Frame AC Motors Explosion Proof Motors Severe Duty Motors DC Motors Energy Efficiency
BR 435 BR 454 BR420 BR 600 BR 458

Super-E Motors Washdown Duty Versaflex AC & DC Series 15H & 18H Inverter & Vector Drive
BR 457 Products Motor Controls Inverter & Vector Drives Motors
BR 455 BR 735 BR715 BR 400

www.baldor.com
AC and DC Industrial Motors and Drives

European Product Catalogue 501E

Baldor Value Formula

Vp = Qp x s p
CxT
Q = QUALITY S = SERVICE
C = COST T = TIME
P = PERCEIVED

The Baldor Value Formula is at the


core of everything we do. From
design to manufacturing, to sales
and service, the Value Formula is the
cornerstone from which we operate.

The formula illustrates the equal


importance of four factors shaping our customers’ perception of Value. We constantly make improvements in the
Quality of our Products. We strive to improve the of Service to our customers, making their jobs easier. By improving
Quality and Service while reducing the ownership Cost of our products and the Time it takes to deliver products to our
customers, our Value (as perceived by the customer) continues to increase.... year after year.

Baldor’s Mission Statement


To be the best (as determined by our customers) marketers, designers and manufacturers of
industrial electric motors, drives and generators.

Baldor UK Ltd Baldor ASR AG


Tel: +44 (0) 1454 850000 Tel: +41 (0) 52 647 4700 Local Distributor:
Fax: +44 (0) 1454 859002 Fax: +41 (0) 52 659 2394
email: [email protected] email: [email protected]

Baldor ASR GmbH Baldor Italia S.R.L


Tel: +49 (0) 89 90508-0 Tel: +41 91 640 99 50
Fax: +49 (0) 89 90508-491 Fax: +41 91 630 26 33
email: [email protected] email: [email protected]

© Baldor UK Ltd
www.baldor.com 06/04
501E Printed in the UK