Annexure IV Specifications of Equipments For CCTV System: Fixed Day/Night IP Box Type HD Camera (OUTDOOR Application)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

Annexure IV

SPECIFICATIONS OF EQUIPMENTS FOR CCTV SYSTEM

I Fixed Day/Night IP Box type HD Camera (OUTDOOR Application)-


Free issue from BPCL ( Specifications enclosed as Annexure- a)
Application Outdoor (The camera to be used for constant surveillance of
critical plant areas, viz. security gate, pump houses, TLF Gantry
etc. (Petroleum Oil depots / terminals) . Glare from street
lights should not affect video quality at night.

II High Speed Dome type Day/Night IP PTZ Camera (OUTDOOR Application)


FEATURES MINIMUM REQUIRED PARAMETERS
CAMERA & VIDEO
1 Application Outdoor (The camera to be used for surveillance of plant
(Petroleum Oil depots / terminals) area / perimeter). Glare
from street lights should not affect video quality at night.
Day & Night Operation (Automatic switchover from color
mode to Monochrome Mode when the light falls below a
certain threshold level)
2 Sensitivity (Minimum 1.0 Lux Day Mode (Color)(SENS UP off ) & 0.1 Lux Night Mode
Illumination) (Monochrome) (SENS UP off ) ( Sensitivity shall be measured
@ F1.4, IRE-30
3 Image Sensor 1/3” Progressive Scanning CCD/CMOS Color Sensor
4 Lens Varifocal
5 Lens Focal Length 4.7-94 mm

6 IR Cut Filter Automatic removable IR Cut filter


7 Electronic Shutter Digital (Auto / Manual selectable) with Speed of approx. 1 -
1/10,000 second to capture clear picture / video as per
specifications
8 Iris Type Auto ( Video drive)
9 Lens Zoom
(18X Optical & 10X Digital )
10 Presets 90 with +-0.1° accuracy
11 Programmable Patterns 8 (Eight) including Pan, Tilt & Zoom tour functions
12 Flip Function Auto endless
13 Pan movement 360° (endless) continuous pan rotation
14 Tilt Range 0° to more than 90° vertical

15 Pan Speed Variable between 80°/sec to 0.1°/sec (Adjustable through


software, also possible manually)
16 Tilt Speed 0.1 deg. To 40°/sec (Manual operation)
17 Zoom Speed Adjustable
18 Wide Dynamic Range Yes (Min. 50 DB)
19 Television System PAL
20 Video Streaming/ Video Multiple (3), individually configurable streams in H.264 &
Compression Motion JPEG.

21 Auto image stabilizer On/Off (Selectable)


22 Uni -casting & Multicasting
feature Required
23 Aspect Ratio Compatible to HD (16:9)
24 Minimum Resolution (in 1920 (V) X 1080 (H) (TRUE HD)
Pixels
25 Frame Rate 25 fps @ PAL
26 S/N Ratio 50 Db or More
27 Automatic Gain Control On / Off (Selectable)
(AGC)
28 White balance Automatic with Manual Override (2,000° to 10,000°K)
29 Back Light Compensation On/Off (Selectable)
(BLC)
30 Image settings Compression, color, brightness, sharpness, contrast, white
balance, exposure control, backlight compensation, exposure
zone, automatic back focus, mirroring of images, WDR,
dynamic contrast, text & image overlay, privacy mask.
31 Software Interface Web Browser
32 Image Enhancement feature Yes
33 Tilt & Zoom Display On Screen
34 Privacy Zone masking Yes (6 zones)
35 Frame Freezing Yes
36 Auto focus Yes
37 Alarm triggers Intelligent video, external inputs
AUDIO
38 Audio streaming Minimum One-Way , uni-Directional transmission of voice.

39 Audio Compression AAC LC 8/16 kHz./G.711 PCM8kHz./G.726


ADPCM8kHz.Configurable bit rate
40 Audio Input/output Built-in microphone or port for connecting External
microphone input. Signal Line in / Line out to support audio
inputs & outputs. ( Ports required to pick up sound along with
video are optional)
NETWORK / Built –in
Analytics & SECURITY
41 Security Password Protected access, IP address filtering & user access
log facility
42 Supported Protocols TCP/IP, UDP/IP (Unicast, Multicast IGMP), UPnP, DNS, DHCP,
RTP, RTSP, NTP, IPv4, SNMP v2c/v3, QoS, HTTP, HTTPS, SSH,
SSL, SMTP, FTPand 802.1x (EAP).
Camera shall support open IP standards.

43 Service Port PAL output

GENERAL
44 Power Source 230 V AC supply shall be made available in the control room.
Vendor shall arrange to make necessary cabling from the BPCL
provided source to the camera
45 Dome Housing NEMA 4X certified IP-66 rated (Weather & Dust resistant) with
an aesthetic appeal.
Cast Aluminum (To be suitable for Coastal Environment)
In-built sun-shade & heater as applicable for achieving desired
performance ( 24/7)
Easy cable routing
Impact Resistant (IK10++ per EN62262 (50 J)
Vandal / Tamper Resistant
Make to be same as that of camera.
Shock & Vibration Resistant
Mounting Pendant type. As per site conditions. Adjustable head with 360
46
deg pan, 180 deg tilt. Make to be same as that of the Camera.
47 View Material (Dome Polycarbonate Plastic / Acrylic Plastic / Tempered Glass
Bubble)
48 Connectivity Ethernet (RJ-45 Connector) for 10/100 Mbps speed.
49 Internal Heat Sink Required
50 Mounting Pendant mount / as per site requirement. Make to be same as
that of the camera.
51 Mechanical Adjustment Pan (350°), Tilt (180°) ,Rotate (200°)

52 Operational Temp. 0° to 50° C

53 Operating Humidity 20% to 90% RH (non condensing)

54 Accessories The cost of Camera shall include all the required accessories,
connectors etc to connect Camera with Cat-6 Cable & for
mounting on the pole.

Surge arrestor ( in-built ) or external for power & Ethernet


circuits
Certifications & Approved
makes
55 Certifications IEC standards viz.IEC 60068-2-6 or as applicable. FCC standards
viz.FCC part 15 or as applicable, EN standards viz. EN 55022,
55024 or as applicable, UL or Vds standards viz. UL60950-1 or
as applicable. (Model specific)
56 Application Programming Camera shall be ONVIF certified with suitable SDK ‘s & API’s to
Interface be supplied with the camera
58 License Fees: No license fees shall be payable over & above the rates quoted by the bidder in
this tender for operating & accessing cameras as well as for firmware up gradation
throughout the contract period including comprehensive AMC period ( 2 + 3 years)

Video Management Software (Viewing, Recording and Playback Software)


III
( Type-I locations :32 CAMERAS), Type-II locations : 64 CAMERAS)
The software should allow seamless integration of third party security
infrastructure.
The Software should be a highly scalable enterprise level solution. It must
offer Video Management solution scalable from 1 camera to 16/32/64
cameras as per BOQ. (Minimum).
Shall support IP Cameras & Encoders (for analog camera interface)
The VMS shall be based on open architecture which facilitates integration
with other IT systems , Owner supplied free-issue cameras with the help of
API (distributed free of charge). Shall be ON/VIF compliant.
The system shall allow operation with PC Keyboard, Mouse, CCTV Keyboard.
Shall be able to view single and multiple cameras simultaneously.
Software The software should provide user licenses for at least 5 users per site and
1 Functional camera licenses as per the number of cameras to be installed at site as per
Requirement bill of material & shall be scalable for 32/64 cameras in future as the case
may be.
Remote Administration, Monitoring & Management of Video at Plant level.

Facility for exporting the video.


Alarm pop ups for the associated cameras.
Shall be able to view single and multiple cameras simultaneously.
The software should provide user licenses for at least 5 users per site and
camera licenses as per the number of cameras to be installed at site as per
bill of material & shall be scalable for 32/64 cameras in future.
Remote Administration, Monitoring & Management of Video at Plant level.

Facility for exporting the video / viewing through internet


Alarm pop ups for the associated cameras.
The software should be compatible with Windows Operation Systems
2 Platform (Windows Server 2003 / Windows Server 2007 / Windows Server 2008)
The VMS should be built on open standard and shall be compatible with
3 Compatibility products from industry leading manufacturers.
Logical camera grouping
4 Viewing Simultaneous viewing live and recording from various Cameras by multiple
users (min. 8 cameras view simultaneously)
Drag and Drop Camera Viewing.
Multi camera sequential tours
The VMS should have viewing client to enable the feed display on the
workstation / remote location.
Extended camera viewing on multiple monitors
Remote viewing of cameras through internet.
Digital zooming feature
User friendly PTZ Control functions of PTZ Camera.
Support Multiple Video Resolutions (CIF, 2CIF, 4CIF & HD (up to 8 MP))
Should have feature of recording and retrieval of Video and Audio.

Continuous recording, by trigger (motion or alarm), by schedule.


Recording &
5
Retrieval Should support the recording of H.264, MPEG-4 & MJPEG compressions

Should have Configurable recording rate per camera


Multi level storage: should support multilevel storage (live recording on
primary disk, archiving on secondary, and so on) should delete video after
6 Storage configurable duration.
Distributed , fault tolerant database architecture
Video smart search on the basis of date, time, event, camera , location &
alarm
Should have advanced / smart / quick search function
7 Video Search Sorting by camera name & IP Address.
Should be able to export searched video to standard video codec (or with
video player in case of proprietary format)
Quick review of upto 60 minutes of data.
Register event, associated video and alert operator on screen with audio.
Event
8 Motion detection, sound detection, camera tampering events should be
Management
alerted to the operator.
Show connection status of cameras, alert operator on screen with audio
Camera Manage firmware upgrades, setting IP address. Set camera settings such as
9
Management brightness, contrast etc.
User management, password management, user access level management
10 Security

11 Configurations Various layout configurations (2X2, 3X3 & 4X4)

-user-friendly PTZ Controls


-Graphic video footprints with real-time PTZ controls
General
-Sensor management tools, Alarm management options
12 Features &
and data editing.
Specifications
-Enhanced displays for video forensics and access to
video archive systems
-Supports JPEG or BMP or GIF data input
-Capable of managing an assigned area of interest
-Capable of ingesting video and sensor inputs into an
open architecture format, onto one screen
-Provides a monitoring capability of the video/sensor
Subsystem, to be relayed to the key operations centre.
-Provides a multiple perspective geographic display of
site locations with site specific surveillance information
including sensor locations and alarm conditions.
-Provides a remote ability to set and/or modify
Operational characteristics of surveillance devices and
Storage
-On line control of Pan/Tilt/Zoom (PTZ) cameras, sensors
-Ability to record and retrieve stored video
-Integrated-alarm visualization rule and device control
displays in either a single or double monitor format
-Ability to slue PTZ cameras to alarm generated areas
-Capability of Real time analysis of connected cameras
to detect abnormal activity and security threats.
-Capability to filter large amounts of video and support
display of time line, customizable site Map, Live
Video, Video playback, Integrated site map, Remote
live view,Multi site capability, Event based recording all
over local LAN
-Ability to deploy the alarm components on PC
Computer servers or on remote, ruggedized, externally
mountable, stand alone platforms.
-Camera obstructed should activate alarm if the field of
view is obstructed.
-Cord cut-will alarm if the video signal is lost.
-Hardware alarm input – should be able to receive
signals from external devices through alarm I/O and act
accordingly
-Software should be an open IP surveillance product, enabling simultaneous
digital video recording from network,mega pixel and analog device,
intelligent video analysis and remote access to live and recorded images
from any networked computer.
-Software should allow to add, edit, delete or disable and enable policies for
video management.
-Option of remote viewing over handheld moblie set (3G) to keep updated
while in the field.
-Software should be jointly and simultaneously able to manage video
analytics and video management as one product.
-Software should be able to store video to local harddisk, a RAID
configuration or even a storage-area network (SAN).
-Software should support display of time line, customizable site Map, Live
Video, Video playback, Integrated site map, Remote live view, Multi site
capability, Encryption, Event based recording.
-Option of on screen digital video tracking & digital zoom on tracked area.
-Option of on screen object follow thru within tracked area
-Management of recorded video with on screen time graph and multiple
color coded event indicators for selective and simultaneous view of alarm
and non alarm situations for quick viewing
-User friendly and time graph based selection for playback and instant
archival of video events on external media
-On selection of specific area on video with specific date and time period,
instant retrievals of all past events/activities at this selected area should be
retrieved and viewed instantly as a single video/movie clip
-Insertion and deletion of Cameras
-Software forensics analyzer shall allow the user to quickly search for and
detect security events that occurred in the past. Example includes –
- Scan days and weeks of pre recorded video within minutes
- Locate and extract information about potential security breaches
- Allow users to run regular quaries to detect patterns
- Allow users to apply any rule to any amount of collected or stored
video data
-Software shall provide the ability to set up security rules for surveillance
cameras.
-Software shall be able to create rules and responses based on digital or
contact closure input events from external devices, such as critical
infrastructure-related events, Network connection failures, Fatal errors,
Hard Disk failures, Software service down, Video encoder failures, Security-
related events, Digital input pin change, Video lost, On screen alarms,
Maintenance related events, User event notification using SMTP (Mail)
-Software shall be able to perform the following tasks simultaneously:
a. Digitizing and compressing video
b. Writing video to files on local hard disk and
maintaining an accurate index of the stored video file
c. Deleting older video files as needed, to free up space
to record newer video files
d. Selectively transferring recorded video to long term
storage media
-Software shall be capable of managing online storage that is, online video
shall be available for immediate playback. Storage shall be intelligently
managed so that the video that is most likely to be requested by users will
be retained online.
-Generating and managing system logs and audit reports, define the
reporting level for system events generated by various services, Filtering log
files and events, system availability
-Updates as & when required during contract period shall be done with out
additional cost. Original licensed copy of the software shall be supplied
along with the system.
- Uptime of CCTV System should be available in a module. The same to be
available based on Query as daily, weekly, Monthly, Quarterly & yearly.
Uptime of CCTV system is considered as 100 % when all the cameras (“n”
no.s) & system functionality are operational. If one camera is down &
balance cameras (n-1) are available fully with all system functionalities,
uptime shall be (((n-1)/n )*100 ) %.
13 Certifications Soft ware shall be ONVIF compliant
Nice, Mirasys, Milestone, Vicon, Honeywell, Dvtel, Verint , Axis, Genetic,
Approved Mindtree . Vendor can offer any other reputed make software provided
14
Makes bidder shall submit Proven Track Record from the user at least one year
from tender due date along with the bid and it is subject to BPCL approval.

Video Management / Video Analytics / Network Video recording Server - For type-1
IV
locations having maximum 36 cameras
FEATURES MINIMUM REQUIRED PARAMETERS
Should be compatible for loading video analytic software(
supporting ON-VIF protocol) from any third pary. Also shall
General requirement support in-built analytics of any ON/VIF compliant camera,
issued with this tender or to be installed at later date during
Comprehensive AMC period

1 Processor Type Intel Quad Core 2.0 GHz- Xeon processor ( 3 GB Ram)
Hyper Threading
2
Technology support Yes (2 threads / core)
Turbo boost Technology
3
support Yes
4 Internal L3 Cache 12MB
5 BIOS Type Unified Extensible Firmware Interface (UEFI)
6 Standard Memory 8 GB expandable up to 16 GB
7 DIMM Slots 11
8 Memory Access Speed 1066MHz
9 Memory Mirroring Support
Yes / 1 channel (2 slots per processor) active, 1 spare, 1 unused
10 Storage Technology Hot-swap SAS/SATA, simple-swap SATA
11 No of HDD Bays 8 ( hot-swap, with internal backup drive)
16 TB ( Combination of min.2 TB (Internal) & min. 14 TB
12 Hard Disk Capacity external ( with provision of adding additional 8 TB later &
provision for taking back-ups)

13 Drive Capacity Supported


250GB, 500GB, 1TB, 2TB
14 RAID Supports RAID 5 configuration
15 No of Video Ports Dual
16 Video Memory 16 MB DDR3 SDRAM
17 Maximum video resolutions 1980x1080 at 50Hz (32 bits)
18 Gigabit Ethernet controller Intel 82575
19 No of Gigabit Ports 2
20 No of USB Ports 5
Yes (IMM)
Integrated systems
21
management controller

NVIDIA Quadro 600,CUDA Cores: 96,Total Frame Buffer: 1 GB


DDR3,Memory Interface: 128 bit,Memory Bandwidth: 25.6GB/s
Display Port: 1,Maximum Display resolution: 2560 x 1600
22 Video Graphics Card
Shader Model: 5.0,OpenGL: 4.0,Microsoft Direct X: 11
NVIDIA CUDA Architecture: Yes, Mosaic Technology: Yes
Display Management Software: Yes, FSAA (Max): 64 x
Optional systems
23
management adapter Virtual Media Key (optional)
Predictive Failure Analysis
24
(PFA) support Memory, HDDs, and the onboard battery
25 No of Power Supplies 1 +1 ( redundant)
26 No of cooling fans 4 (As per the server design)
Windows Server 2003 / Windows Server 2007 / Windows
27 Operating System Server 2008, should be compatible with the supplied video
management software and analytics.
Norton (Latest) or approved equivalent with free upgrades till
28 Anti Virus
validity of contract including comprehensive AMC period
29 Approved makes IBM, HP, Dell

Video Management / Video Analytics / Network Video recording Server (Type-2 locations
IV having maximum 72 cameras)

FEATURES MINIMUM REQUIRED PARAMETERS


Should be compatible for loading video analytic software(
supporting ON-VIF protocol) from any third pary. Also shall
General requirement support in-built analytics of any ON/VIF compliant camera,
issued with this tender or to be installed at later date during
Comprehensive AMC period
1 Processor Type Intel Quad Core 2.4 GHz- Xeon processor ( 4 GB Ram)
Hyper Threading
2
Technology support Yes (2 threads / core)
Turbo boost Technology
3
support Yes
4 Internal L3 Cache 12MB
5 BIOS Type Unified Extensible Firmware Interface (UEFI)
6 Standard Memory 8 GB expandable up to 16 GB
7 DIMM Slots 11
8 Memory Access Speed 1066MHz
9 Memory Mirroring Support Yes / 1 channel (2 slots per processor) active, 1 spare, 1 unused
10 Storage Technology Hot-swap SAS/SATA, simple-swap SATA
11 No of HDD Bays 8 ( hot-swap, with internal backup drive)
16 TB ( Combination of min.2 TB (Internal) & min. 14 TB
12 Hard Disk Capacity external ( with provision of adding additional 16 TB later &
provision for taking back-ups)
13 Drive Capacity Supported 250GB, 500GB, 1TB, 2TB
14 RAID Supports RAID 5 configuration
15 No of Video Ports Dual
16 Video Memory 16 MB DDR3 SDRAM
17 Maximum video resolutions 1980x1080 at 50Hz (32 bits)
18 Gigabit Ethernet controller Intel 82575
19 No of Gigabit Ports 2
20 No of USB Ports 5
Integrated systems
21
management controller Yes (IMM)
NVIDIA Quadro 600,CUDA Cores: 96,Total Frame Buffer: 1 GB
DDR3,Memory Interface: 128 bit,Memory Bandwidth: 25.6GB/s
22 Video Graphics Card Display Port: 1,Maximum Display resolution: 2560 x 1600
Shader Model: 5.0,OpenGL: 4.0,Microsoft Direct X: 11
NVIDIA CUDA Architecture: Yes, Mosaic Technology: Yes
Display Management Software: Yes, FSAA (Max): 64 x
Optional systems
23
management adapter Virtual Media Key (optional)
Predictive Failure Analysis
24
(PFA) support Memory, HDDs, and the onboard battery
25 No of Power Supplies 1 +1 ( redundant)
26 No of cooling fans 4 (As per the server design)
Windows Server 2007 / Windows Server 2008, should be
27 Operating System compatible with the supplied video management software and
analytics.
Norton (Latest) or approved equivalent with free upgrades till
28 Anti Virus
validity of contract including comprehensive AMC period
29 Approved makes IBM, HP, Dell

V Workstation: Workstation consists of a CPU and a Monitor, (A,B or C as per BOQ)


A Specifications for Workstation CPU
FEATURES MINIMUM REQUIRED PARAMETERS
1 Processor Intel Xeon W3550 Dual Core
2 Cache 4 MB
3 Storage Connector 5 X SATA Connector
4 Drive DVD
5 Memory DDR (2 GB)
6 Audio Support Yes
NVIDIA Quadro 600
CUDA Cores: 96
Total Frame Buffer: 1 GB DDR3
Memory Interface: 128 bit
Memory Bandwidth: 25.6GB/s
Display Port: 1
Maximum Display resolution: 2560 x 1600
7 Video Graphics Card
Shader Model: 5.0
OpenGL: 4.0
Microsoft Direct X: 11
NVIDIA CUDA Architecture: Yes
Mosaic Technology: Yes
Display Management Software: Yes
FSAA (Max): 64 x
8 Ethernet 10/100/1000 Slot
9 HDD Bays 5 (Internal)
10 External Ports USB (8 ports)
11 Peripherals Multimedia Keyboard, Mouse & VGA Monitor slots
12 Storage 1 TB
- 32” at Location In-Charge’s Cabin
Display (Monitor as per
- 22” at Control Room and Security Cabin
13 specifications given in item
no 7.2 a and 7.2 b) (Pl. refer detail Specifications provided separately in item no
7.2 a and 7.2 b)
Windows 2007 / Windows 2008 (Compatible with Client
14 Operating System
software)
Norton (Latest) or approved equivalent with free upgrades till
15 Anti Virus
validity of contract including comprehensive AMC period
16 Approved makes HP, Dell, IBM
B Monitor-32” Flat Screen for workstation: (To be provided at Location In-Charge’s Cabin)
Feature Parameter
1 Type LED
2 Resolution High Defination resolution of 1920 x 1080 pixels
3 Internal Speakers 2
4 Front Controls Power On/Off with LED

5 Scan System Automatic NTCS/PAL; 31.5 – 80 Hz (Horizontal); 56-75 Hz


(Vertical)

6 Video connectors BNC (Composite Video)-2 Channels (looping);4-Pin Mini


DIN(Y/C Video) DVI-I,15 pin D-Sub for VGA/SXGA Audio Inputs
PC Audio (mini jack) Video Audio (2 Channel RCA –looping)
7 Input Composite Video / AV/VGA/HDMI/COMPONENT
8 Power Input AC Input- 100 to 240 V – 0.5 A,50/60 Hz
9 Power Output DC Output – 12VDC,0.5 A
10 Power Cord Detachable IEC
11 Display Mode DVI-I/SXGA/XGA/VGA
12 Display Colors 16.7 Millions
13 Luminance 400 cd/m2
14 Contrast Ratio 50000:1 (Dynamic), 1000:1 (Typical)
15 Viewing Angle 1400 Horizontal, 1600 Vertical
16 Operating Temperature 5OC to 40OC
17 Storage Temperature -25OC to 60OC
18 Operating Humidity 30% to 80% relative, non-condensing
19 Emmissions FCC: Part 15, Class B
20 Immunity CE: EN55022: 1998/A1:2000/A2:2003
21 Safety UL/Cul:6500,EN60950-1:2001
22 Make Samsung, Sony, Sharp, Toshiba, Philips, LG
Monitor-22” Flat Screen for Workstation:
C
(To be provided at Control Room and Security Cabin)
Feature Parameter
1 Type LED
2 Resolution High Definition resolution of 1280 x 1024 pixels
3 Internal Speakers 2
4 Front Controls Power On/Off with LED
5 Scan System Automatic NTCS/PAL; 31.5 – 80 Hz (Horizontal); 56-75 Hz
(Vertical)

6 Video connectors BNC (Composite Video)-2 Channels (looping);4-Pin Mini


DIN(Y/C Video) DVI-I,15 pin D-Sub for VGA/SXGA Audio Inputs
PC Audio (mini jack) Video Audio (2 Channel RCA –looping)
7 Input Composite Video / AV/VGA/HDMI/COMPONENT
8 Power Input AC Input- 100 to 240 V – 0.5 A,50/60 Hz
9 Power Output DC Output – 12VDC,0.5 A
10 Power Cord Detachable IEC
11 Display Mode DVI-I/SXGA/XGA/VGA
12 Display Colors 16.7 Millions
13 Luminance 400 cd/m2
14 Contrast Ratio 500:01:00
15 Viewing Angle 1400 Horizontal, 1350 Vertical
16 Operating Temperature 5OC to 40OC
17 Storage Temperature -25OC to 60OC
18 Operating Humidity 30% to 80% relative, non-condensing
19 Emmissions FCC: Part 15, Class B
20 Immunity CE: EN55022: 1998/A1:2000/A2:2003
21 Safety UL/Cul:6500,EN60950-1:2001

22 Make Samsung, Sony, Sharp, Toshiba, Philips, LG

VI Industrial Grade Layer 2 managed Network Switch for outdoor applications


Features Minimum Requirements
Layer 2 managed switch with eight
Ports 10/100 Mbps N-way fast Ethernet switch with two no.
1000 Mbps fiber optic ports for distances up to 10km &
above. Self-test/alarm output for reporting errors Dual
1 Switch configuration
redundant power inputs with MIL- STD-1275 surge and spike
protection DIN rail or direct panel mounting (no extra kits
required). shall be compatible for access control signals, if
required
2 Ether net performance
A Operation Store and forward wire speed switching, non-blocking.
Full or half duplex operation with flow control supported on
B Modes
all ports
C MAC Addresses 8000
D Switching capacity >5 Gbps
Capacity in Millions of
packets per second >4 mpps
(mpps)(64-byte packets
5 micro sec for 1000 Mbps and 16 micro sec for 10 Mbps (plus
E Latency (typical)
frame time)
F Ethernet Isolation 1500 Vrms 1 minute
3 RJ45 Copper Ports

A RJ45 Ports Min. 8 Nos of RJ45 ports that are fully IEEE 802.3 compliant

B POE Support Min 2 Ports (max support class 3, 15.4W per port)

C RJ45 Speed & duplex Auto-detecting for speed(10/100)& duplex ( full or half)

Auto-mdi/mdix-crossover automatically. supports either


D RJ45 MDI/MDIX
straight or crossed cables

Auto-polarity for automatic correction of crossed TXD and RXD


E RJ45 Polarity
pairs
4 Fibre Optic Ports
Min. 2 no. of 1000 Mbps fibre optic ports for distances up to
A Fibre Optic ports
10 km
B Port speed 1000BaseFX (1000 Mbps)

C Fibre duplex operation full duplex

D Transceivers SC or ST style

E Single Mode Links up to 10 km typical; 1310 nm; with 9-10/125 um fibre

F Safety IEC60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11

5 Networking Features
Standard 802.1d spanning tree support. Fast convergence
A Spanning tree protocol (STP) using 802.1w(Rapid spanning Tree (RSTP), enabled by default
Multiple spanning tree instances using 802.1s(MSTP)
Support for IEEE 802.3ad Link Aggregation Control Protocol (
LACP)
B Port Grouping  Up to 8 groups
 Up to 8 ports per group with 16 candidate ports for each
(dynamic)803.3ad link aggregation
Support for up to 256 VLANs simultaneously, Port based and
802.1Q tag – based VLANs, MAC-based VLAN, Management
C VLAN
VLAN, Private VLAN Edge (PVE), with multiple uplinks, Guest
VLAN & Unauthenticated VLAN
Voice traffic to be automatically assigned to a voice specific
D Voice VLAN
VLAN and treated with appropriate levels of QoS
supported by all All IEEE 802.3 compliant devices are
E Devices
supported
All IEEE 803.2, QoS/CoS/ToS/DS, port mirroring,broadcast
F Protocols & features
storm protection, Modbus monitoring
Industrial Protocols Modbus/TCP, Ethernet/IP, PROFInet, Foundation Field bus HSE
G
Supported and others
Ethernet Communications
Standard
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX/FX
IEEE 802.3ab 1000Base-T
IEEE 802.3z Gigabit Fiber
H IEEE 802.3ad LACP
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.af Power over Ethernet (Mode A)
IEEE 802.1d Spanning Tree/IEEE 802.1W Rapid Spanning Tree
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN Tag
IEEE 802.1x User Authentication (Radius)
IEEE 802.1ab LLDP
Port Connector 10/100TX:RJ-45 x 8
SFP Combo: RJ-45 x 2,
100/1000 SFP x 2
Console port : RJ45 x 1
Wire-Speed forwarding rate
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Ethernet
1,488,000pps for 1000Mbps Ethernet

Performance Mac Address : 8K


Packet Buffer : 1Mbits

Wire-Speed forwarding rate


I
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Ethernet
1,488,000pps for 1000Mbps Ethernet

DRAM 32Mbytes
Flash ROM : 4Mbytes
Switching Fabric : 5.6Gbps
Throug hput 8.3Mbps@64bytes (Full Duplex)

Management

Configuration SNMP v1/v2c/v3, Web, Telnet, CLI

VLAN IEEE 802.1Q, GVRP, Port-based VLAN


Up to 4096 VLAN ID

Redundancy X-Ring, Dual Homing and Couple Ring,


IEEE 802.1d STP and IEEE 802.1w RSTP

J Security IP Access security, port security, DHCP


Server, IP Binding per Port, IEEE 802.1x
Port Access Control

Traffic control IGMP Snooping/ Query for multicast


Port trunking, Static IEEE 802.1p QoS/
CoS/ToS/DSCP priority queuing, IEEE 802.3 x flow control

Diagnostics Port Mirroring, LLDP,Real time traffic statistic, MAC Address


Table, SNTP, Syslog, E-mail Alert, SNMP Trap, RMON
Mechanism Enclosure IP30, Metal with aluminum shell
K
Installation DIN-rail/Wall Mount Design

L TFTP Firmware update, system configure restore and back-up


SNMP v1/v2c/v3, Web, Telnet, CLI
M
Management
• Provides standards-based IEEE 802.3af
• Power over Ethernet upto 8 ports of class
N
3 powered devices at 15.4 watts
• Ingress Packet Filter and Egress Rate Limit
System: Power, Power 1, Power 2, Fault, Master
LED Indicators
10/100TX : Link/Activity, FDX/COL

N Giga Copper: Link/Activity, Speed

SFP: Link/Activity

6 Power and Alarm Output

a Power Input Dual redundant power inputs for redundant power supplies

b Input Voltage Range 10 to 50 VDC


c Power Typical with all ports linked and active
Industrial surge & spike
d 15 kW peak, 5 kW (10 times for 10 us)
protection
MIL-STD-1275 surge and Surge: 100V for 1 second ... Transient: 15,000 watts peak
E
spike protection (All models) Spike: 250 volts (50 times for 100 uS)
F Self-test / Alarm Same voltage as power input; 0.5 Amps
g Output max.
7 Environmental
a Operating temp. 0 to 60°C
b Storage Temperature 0 to 50°C
c Humidity 5 to 95% RH (non-condensing)
d Vibration IEC6008-2-6
e Shock IEC6008-2-27
f Freefall IEC6008-2-32
8 Standards and Certifications
Relevant UL standard viz.UL60950 etc. or as applicable,
a Standard safety Relevant EN standards viz. EN60950-1 etc or as applicable.,CE
Marking

B Mechanical stability Shock—20g (operational), 30g (nonoperational)


IEC 61000.Relevant IEC standards, viz. IEC 60950(CB) etc. or as
C EMC interface immunity
applicable
d EMC (Standard & industrial) FCC part 15, ICES-003, EN55022, IEC60533

UL1602, CSA22.2/213 (Class I, Div. 2, Groups A, B, C, D);


E Hazardous Locations
Cenelec EN50021 (Zone 2), IEC 60079-15
g Traffic NEMA TS-2 rated for traffic control systems
H Marine and Off-shore DNV (Det Norske Veritas) No. 2.4.
I MTBF Mean Time Between Failure: >1,00,000 hours.
J RoHS and WEEE RoHS (Pb free) and WEEE compliant.
k Certifications CE, FCC Class A & UL (UL/cUL60950-1), EN61000-6-4,
EN61000-6-2, EN61000-4-2 (ESD), EN61000-4-3 (Radiated RFI),
EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN61000-4-6
(Induced RFI), EN61000-4-8 (Magnetic Field), IEC60068-2-27,
IEC60068-2-32 & IEC60068-2-6.
9 Mechanical
a Case Low Profile, Ideal for shallow enclosures and tight spaces

b Material Rust-proof Lexan and aluminum with clear protective coating

c Protection IP 30
DIN rail or direct to panel (no optional kits or accessories
d Mounting
required)
The layer 2 switch shall be enclosed in a IP 65 enclosure with
e Enclosure
cooling fan.
Cost of level-2 switch shall include cost of connecting OFC &
f Accessories/ connectors
CAT-6 cables from the cameras to the switch
g Make Cisco, Ruggedcom, Garretcom, Allied Telesis
10 Quality of service
a Priority levels 4 hardware queues

b Scheduling Strict priority and weighted round robin (WRR)

Port based ; 802.1P VLAN priority based ; IPv4 precedence/type


c Class of service of service(ToS)/DSCP based ; Differentiated services;
classification and re-marking ACLs, trusted QoS.
Ingress policer; egress shaping and rate control; per VLAN, per
d Rate limiting
port & flow based
Layer 3 managed Switch for indoor applications ( Layer-2 switch shall also be acceptable
with configuration of ports as given below & specifications of layer-2 switch as given
above).
VII
Purpose of this switch is to integrate the layer-2 switches provided in the field with NVR
server/ VMS & for uploading the videos through internet.
FEATURES MINIMUM REQUIRED PARAMETERS
1 Ethernet Ports 24 X 10/100/1000 Base-T
4 X 1000Base-XSFP Combo ( Single mode) To be expandable to
2 Fiber ports accommodate additional 4 no.OFC connections for locations ( 64
cameras)
32MB SDRAM
16MB flash memory
200MHz PowerPC CPU
3 System Capacity 4096 VLANs
16000 MAC addresses
8 Megabytes file system
Packet buffer memory 1Mbit
Wire speed switching on all Ethernet ports
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Ethernet
4 Performance
1,488,000pps for 1000Mbps Ethernet
Ethernet throughput 71.424Mpps
Switch fabric 96Gbps
IEEE 802.3 10T
IEEE 802.3u 100TX
5 Interface Standards
IEEE 802.3z 1000SX
IEEE 802.3ab 1000T
IEEE 802.1d Bridging
6 General Standards IEEE 802.3ac VLAN tag frame extension
IEEE 802.3x Back Pressure / flow control
Static and dynamic port trunking (with six trunk
groups and up to 8 ports per trunk)
IEEE 802.3ad 32 LACP link aggregation1
IEEE 802.1D Spanning-Tree Protocol
IEEE 802.1w Rapid Spanning-Tree
7 Redundancy
IEEE 802.1s Multiple Spanning-Tree
BPDU guard1
Loop guard1
Router Redundancy Protocol (RRP) snooping
Dual software images, dual configuration files
Layer 2, 3 and 4 criteria
Flow groups, traffic classes and policies
DSCP replacement
Traffic Management
8 IEEE 802.1Q priority replacement
Quality of Service (QoS)
Type of Service replacement
Type of Service to IEEE 802.1Q priority replacement
IEEE 802.1q Priority to Type of Service replacement
Maximum bandwidth control
Burst size control
Ingress rate limiting
Head of line blocking prevention
Support for ingress and egress ports
Eight egress queues per port
IEEE 802.1p Class of Service with Strict and Weighted
Round Robin Scheduling
RFC 1112 IGMP snooping (v1)
RFC 2236 IGMP snooping (v2)
RFC 2710 Multicast Listener Discovery
9 Multicast (MLD) snooping (v1)
RFC 3810 Multicast Listener Discovery
(MLD) snooping (v2)
IGMP snooping querier1
RFC 1157 SNMPv1
RFC 1901 SNMPv2
RFC 3411 SNMPv3
RFC 1213 MIB-II
RFC 1215 TRAP MIB
RFC 1493 Bridge MIB
RFC 2863 Interfaces group MIB
RFC 1643 Ethernet-like MIB
RFC 1757 RMON 4 groups: Stats,
History, Alarms and Events
RFC 2674 IEEE 802.1Q MIB
RFC 1866 HTML
Management & RFC 2068 HTTP
10
Monitoring RFC 2616 HTTPS
RFC 854 Telnet server
RFC 1350 TFTP client
IP address allocation:
RFC 951 / RFC1542 BOOTP client
RFC 2131 DHCP client manual
RFC 2030 SNTP, Simple Network
Time Protocol
BootP/DHCP relay
Group link control1
Link flap protection1
Syslog client
Two event logs:
4,000 event capacity in temporary memory
2,000 event capacity in permanent memory
Single IP address for management
Out of Band management (serial port)
Management Access
11
Method In-band management (over the network) using Telnet,
Web browser or SNMP
Enhanced Stacking
Menus
Allied Ware PlusTM CLI
Multiple management sessions
12 Management Interfaces (up to three administrators)
Command line
Web browser
SNMP v1/ v2/ v3
RFC 1492 TACACS+
RFC 2865 RADIUS client
RFC 2866 RADIUS accounting
IEEE 802.1x Port-based network access control
with multiple supplicants per port
ingress and egress control of
broadcast, multicast and unknown
unicast traffic
MAC address security/lockdown
Layer 2/3/4/ Access Control Lists (ACLs)
64 ACL profiles
256 rules per ACL profile
ACLs based on:
13 Security
• Ethernet frame type
• MAC address/VLAN ID/IEEE 802.1p
• Layer 2/3 protocol
• IP subnet/address/TOS/DSCP
• UDP/TCP port/flag
SSHv2 for Telnet mgmt
SSLv3 for Web mgmt
DoS attack protection
Smurf
SYN flood
Teardrop
Land
IP option
Ping of Death
SNMP attack
Microsoft NAP compliant
Symantec NAC support
Bad cable detection
14 Fault Protection
Broadcast storm control
15 MTBF > 200000 hours
16 Operating Voltage 120V to 220 V AC
17 Operating Temperature 0° to +40° C
18 Certifications UL
19 Approved Makes Cisco, HP, Juniper, Allied Telesis, Nortel

VIII Media Converter


FEATURES MINIMUM REQUIRED PARAMETERS
1 Type Ethernet Data to Fiber & Vice-Versa
2 Ports 2 (Two). One Ethernet Port & One Fiber Port
3 Multiplexing Integrated Wavelength Division Multiplexing
4 Auto negotiation Yes (Between 10Mbps & 100 Mbps Data rates)
5 Range Selection 10 Mbps & 100 Mbps
6 Communication selection Full & Half Duplex
7 Link Down Detection Yes
Multimode & Single Mode
8
Support Yes
9 Transmission Device Laser Diode
10 Outdoor Application Yes
11 Switching Method Store & Forward
12 Compliance IEEE 802.3, 802.u, 802.3x
13 Interface Auto MDI / MDI-X
14 LED Indicators Yes
Shock & Vibration
15
Resistant Yes
- Media converter used for outdoor application at Camera
and layer 2 switch end shall be housed in IP65 enclosure
16 Enclosure at the bottom of the pole.
- Media converter used for indoor application at layer 3
switch end shall be housed in proper enclosure.
17 Certifications CE, FCC & UL
18 Operating Temperature 0° to 70°C
19 Operating Voltage 12V DC / 24V AC
Reputed Make as approved by BPCL provided bidder shall
20 Approved Makes submit Proven Track Record from the user at least one year
from tender due date along with the bid.
IX Uninterrupted Power Supply
FEATURES MINIMUM REQUIRED PARAMETERS
1 Topology Online (Double Conversion)
2 Input Power Factor >0.95
3 Nominal Input Voltage 220V/230V/240V (Single Phase)
4 Input Frequency 50/60 Hz (Accuracy of +-5 Hz) Auto Sensing
5 Input Connections 3 Wire
6 Input Voltage Range (Full Load) 160 – 280 V (Single Phase)
7 Input Voltage Range (Half Load) 100 – 280 V (Single Phase)
8 Output Power Capacity 3 KVA / 2100 Watts
9 Output Power Factor 0.7
10 Nominal Output Voltage 230V configurable for 220V, 230V and 240V
11 Efficiency (Full Load) 88%
12 Output Voltage Distortion > than 3%
13 Output Frequency (Sync to mains) 50/60 Hz (+/- 3 Hz)
14 Crest Factor 3:01
15 Waveform Pure Sine Wave
16 Output Connection 3 Wire
17 Backup Battery type Sealed Maintenance free Lead – Acid Battery with
suspended Electrolyte
18 Bypass Built-in
19 Interface Port DB-9, RS-232,Smart Slot
20 Web SNMP Card Interface One
Browser Accessible, Customizable input contacts,
Customizable output relays, Data Logging, Event
Compatible Web SNMP Card for Logging, Fault Notification, Flash Upgradeable, O.S
21 Network Management & shutdown, Password Security, Radius support, Read only
Environmental Monitoring access, Reboot equipment remotely, Run Command File,
Server shutdown, Telenet Management, Temperature
Monitoring
22 Control Panel LED status displays with Load & battery Bar graphs
23 Audible Alarms Battery ON, Battery LOW & Overloading
24 Emergency Power Off (EPO) Optional

25 Filtering Full Time multiple pole filtering, 0.3% IEEE surge let
through and Zero clamping response time
26 Surge Energy Rating 420 Joules
Audible noise at 1 meter from unit
27
surface < 55 Dba
28 Online Thermal Dissipation < 652 BTU/hr

29 Operating -Temperature, Humidity


0° to 40° C , 0-90%
30 Approved Makes APC, Emerson, Numeric, Su-kam, Microteck

X Mounting Pole:
Feature
1 Type Self Support
2 Material Galvanized Steel
3 Height 3 or 6 mtrs as per site requirements
4 Wind Speed 180 Kmph
5 Stress Within acceptable limit
The foundation of pole to be designed for three types of soil
namely soft, medium, hard/rocky.
1. The foundations design to be as per the actual site
conditions.
2. Guard against corrosion and soil erosion should be taken
care of.
6 Foundation 3. The back filling should be done by proper compaction of
soil in layers and should be done before erection M20 concrete
shall be used .Material mixing and quality control of concrete
shall be as per IS 456:2000. High strength deformed steel bars of
grade Fe 415 confirming to IS:456 shall be used. Bending of bars
shall be as per IS 2502 (1963)
4. Welding shall be done as per IS:9595 (1996)
The paints used shall be in accordance with IS 2074/62, 2932 &
2933/75.Before applying coat of primer, the surface shall be
given a coat of pickling agent so as to avoid flaking of painting.
7 Painting The pole shall be given two coats of paint in addition to primer
coat after erection. The pole shall be painted as per the
international standard and civil aviation guidelines.
50x3 mm GI strip should be bonded to the base of the pole and
connected to earth pit / grid (if available in the plant or If a new
8 Earthing earth is to be provided same shall be provided by BPCL) at the
other end (max value of the earth resistance shall be 0.5 ohms).

XI Armoured CAT-6 Cable


FEATURES MINIMUM REQUIRED PARAMETERS
High ACR Values
Low Bit Error Rates
Electromagnetic Compatibility
1 General Features
Minimum Radiations effect
Maximum Noise Immunity
4 Twisted Pairs
Compliant with standards ISO/IEC 11801 2nd Ed., EN 50173-1:
May 2007 (DIN EN 50173-1), DIN 44332-5, IEC 61156-5 2nd Ed.,
EN 50288 x-1, 10Gbase T in acc. With IEEE 802.3an: June 2006,
tested and certified by independent laboratory.

Low-smoke in acc. With IEC 61034, flame-retardant in acc. With


IEC 60332-1 and halogen-free in acc. With IEC 60754-2.

2 Outer Diameter 7.5 mm or lesser (Nominal)


3 Conductor Diameter 0.573 mm (AWG)
4 Conductor Type 23 AWG bare annealed Copper
5 Jacket Material PVC
6 Color Blue / Red / Grey
7 Overall Shield Tined Copper Braiding
8 Electrical Impedance 100 +- 6 Ohms@ 1300 MHz
9 DC Resistance 74 Ohms/km (Max)
10 Voltage Rating 70 V DC
11 Dielectric Strength 1500V/minute
12 Insulation Resistance 500 M Ohms / Km (min) @ 500VDC
13 Velocity of Propagation 69%
14 Certifications UL

15 Approved Makes 3 Com, ADC Krone, Molex, R&M, Digilink, Avaya, Panduit,
Clipsal,Beldon

XII Power Cable


FEATURES MINIMUM REQUIRED PARAMETERS
1 Cable Type Copper
2 Voltage Rating Up to 1000V
3 Size 3 Core 2.5 Sqmm
Annealed Bare Electrolytic Grade Copper Conductor as per IS:
8130/84
4 Construction
Solid Conductor up to 2.5 square mm
Multi stranded conductor for 2.5 sq mm & above
5 Primary Insulation Extruded PVC Compound as per IS: 5831 Type A 0.9 mm nominal
thickness
6 Inner Sheath Extruded PVC Compound Type ST1, Minimum thickness as per
Table 4 of IS: 1554 Part-1
7 Outer Sheath Extruded PVC Compound Type ST1, Minimum thickness as per
Table 7 of IS: 1554 Part-1
8 Armor Galvanized Steel Wire armored dimensions as per table-5 of
IS:1554 Part-1
9 Application Outdoor (Direct Burial in trenches)
10 Core Identification Red, Yellow & Blue

11 Approved Makes Polycab, Finolex, Associated cables, Fort, CCI, Universal cables,
Delton, Belden

XIII Power Cable


FEATURES MINIMUM REQUIRED PARAMETERS
1 Cable Type Copper
2 Voltage Rating Up to 1000V
3 Size 3 Core 1.5 Sqmm
Annealed Bare Electrolytic Grade Copper Conductor as per IS:
8130/84
4 Construction
Solid Conductor up to 1.5 square mm
Multi stranded conductor for 2.5 sq mm & above

5 Primary Insulation Extruded PVC Compound as per IS: 5831 Type A 0.9 mm nominal
thickness

6 Inner Sheath Extruded PVC Compound Type ST1, Minimum thickness as per
Table 4 of IS: 1554 Part-1

7 Outer Sheath Extruded PVC Compound Type ST1, Minimum thickness as per
Table 7 of IS: 1554 Part-1
8 Armor Galvanized Steel Wire armored dimensions as per table-5 of
IS:1554 Part-1
9 Application Outdoor (Direct Burial in trenches)
10 Core Identification Red, Yellow & Blue
11 Approved Makes Polycab, Finolex, Associated cables, Fort, CCI, Universal cables,
Delton, Belden

XIV Fiber Optic Cable


FEATURES MINIMUM REQUIRED PARAMETERS
1 Cable Type Armored Loose Tube Jelly Filled (Multi-Tube), rodent resistant.
2 Fiber Type Single Mode, 9 / 125, 250 micron primary coated buffers

3 Fiber Core As per Telecordia GR20, ITU-T G652D, IEC- 60793-2-50, TIA/EIA
492-CAAB
4 No of Cores 12
5 Armoring Corrugated Steel Tape Armor
BELLCORE GR 20 / IEC 794-1 - Loose tube Corrugated steel tape
6 Cable Construction Type (0.155mm Min)CSTA provided with FRP Rod as strength
members

7 Outer Jacket Construction High density polyethylene, anti - termite, anti - rodent suitable
for direct burial application
8 @1310nm < = 0.35 dB/Km
9 @1500nm < = 0.20 dB/Km
10 Maximum Tensile Load >= 2670 N
11 Maximum Crush Strength >= 2670 N
12 Operating Temperature -20° to +70° C
13 Certifications UL
14 Approved Makes ADC Krone, Molex, R&M, Avaya, Panduit, clipsal, Olex, Digilink

XIV Optical Fiber Cable Accessories


FEATURES MINIMUM REQUIRED PARAMETERS
LIU should be provided for terminating the optic fiber cables. It
shall provide minimum bending radius and the splice trays shall
function as a splice cover for pigtail splicing. It shall be made of
aluminium with power coating in compliance with latest industry
1 LIU standards. Cable glands shall be provided at the cable entry
point for tight sealing. The splice tray shall be made of ABS
materials.24 Port. It shall be fitted with SC couplers and all
accessories for termination. Make-Allied Telesys, Nortal, Cisco,
D-Link.

SC Type; 1 M; Insertion Loss< 0.5 db; Return Loss>40 db; Bend


2 Pigtails Radius>30 mm
Optical Fiber connectors should be single mode SC/ST Type with
3 Optical Fiber Connectors push pull mechanism and fully in compliance with latest industry
standard. Optic fiber connectors should be of standard make.
Optical Fiber adaptors should be suitable for single mode SC/ST
Type fiber cable connectors and shall be fully in compliance with
4 Optic Fiber Adapters latest industry standard. It shall be with snap/latch mechanism.
Optic fiber adapters should be of standard make
Optical Fiber patch cords should be suitable for single mode
SC/ST Type fiber cable connectors and plastic moulded plug type
5 Optic Fiber Patch Cords connectors and shall be fully in compliance with latest industry
standard. It shall be of should be of standard make.Min Return
Loss >50 db
6 Rack 6U 19” Network Rack with cable Managers and 1 fan.
XV CABLE LAYING
The cable has to be laid along the walls or underground through
CABLE LAYING HDPE pipe as per the site conditions at minimum 600 mm depth.
1 Job excludes excavation , back filling & restoration in any kind of
SPECIFICATIONs:
soil & backfilling . Job includes laying of cable, HDPE pipe,
supervision of backfilling etc. to complete the job
The bidder shall quote for Supply & laying of all the cables
[(Power-3C-2.5Sqmm (between Layer3 switch to Layer-2 Switch),
3C-1.5Sqmm (Between Layer 2 switch to MC, PTZ
Camera),(Signal cable- Armoured Cat-6 and OFC)] on RM basis,
excavation for cable laying shall be in BPCL scope:
OFC supplying & laying rates shall include cost of BIS mark HDPE
pipe of 50 MM diameter
CAT-6 cable supplying & laying rates shall include cost of BIS
mark , heavy duty, PVC pipe of 40 MM diameter .
Power cables shall be laid separately in open trench along the
HDPE pipes ( duly clamped) where ever laid above ground
Laying of cable in HDPE pipe trenches/ in ISI mark PVC conduits
on walls/GI pipes to be used for Road crossings. ( G.I. pipes, if
required for raod crossings shall be provided by BPCL)
Pulling of cable through HDPE pipe and GI Pipe and sealing ends
including unused sleevs, including cleaning of pipes. All entries
shall be sealed with sealing compound.
Supplying and providing of MS Clamp of required sizes to hold
the cable firmly to structure/tray. Such clamps also include
wooden bushes if required to be placed around cable, sealing
compound, etc.
All entries shall be sealed with sealing compound.
Underground cable laying shall include termination at both ends,
supply of HDPE pipe for underground cables, supply of ISI Mark
PVC pipe for cables along the walls, supply of GI pipe for road
crossings etc.
Cable route markers @ 30 meter interval to be provided
Bending radius of cables shall not be less than 12 times O.D. of
cable
All cores of cable shall be identified at both ends by means of
PVC ferrule
Cable leads shall be terminated at both ends by crimped type
soldering
Necessary loops of 2-3 m to be provided at a distance in the
multiples of 50 m. As far as possible there shall be no joints in
the cables
All junction boxes, local cabinets, field mounted instruments
shall be connected to the nearby existing earth bus bar / earth
pit through minimum 1.5 mm2 copper conductor at no extra
cost to Corporation. It is included in the scope of the individual
items. Wherever required FLP junction boxes to be used at no
extra cost to Corporation

All equipments and fittings used should be of ISI marked


confirming to relevant IS codes
The shield of the shielded cable shall be earthed with earth at
one end only i.e., at control room end
Note :

1. All the accessories required for the successful commissioning of the system viz junction
boxes, connectors, etc are to be included in costing of the associated item while quoting.

FACTORY INSPECTION: TPIA shall be arranged by vendor to witness performance tests on two randomly
selected equipments. TPIA shall also review all the performance test certificates as per QAP

FAT: Integrated FAT shall be conducted at vendor/integrator’s works for demonstrating all the
performance parameters using randomly selected equipments

SAT : Integrated SAT shall be conducted at BPCL site works for demonstrating all the performance
parameters using randomly selected equipments
Annexure a.

1. IP Network Cameras:

Minimum Specifications
1 BRIEF:
The box type camera shall provide higher resolution (full HD), realtime video images, encapsulated in
Internet Protocol (IP) packets and presented through a 10/100 BASE-T RJ45 Ethernet network connections.
2
RESOLUTION & IMAGER:

Latest Imager 1/3 Progressive Scan, CCD Or High Density CMOS

MegaPixels -1920 X 1080 resolution (1080P full HD)– Minimum Standard

The image resolution shall be not be less than 1920(H) x 1080(V) pixels at 30 frames/sec (NTSC 30 & PAL
25 PAL) .

FRAME RATE:
3 The camera shall produce a frame rate of 30 frames(NTSC 30 & PAL 25 PAL) per second (fps) at minimum
resolution of 1920(H) x 1080(V) , (1080p Full HD) with H.264 compression ratio.
4 STREAMING :
Camera should support multiple steaming with minimum requirement of three (3) H.264 independent
streams at default resolution of 1920 X 1080 (1080P full HD). For resolution, multiple options of resolution
like 720P, VGA,QVGA, etc should be available for selection for any particular stream.
5 DAY & NIGHT CAMERA :
The camera shall have IR cut filter which shall switch from color to monochrome automatically by sensing
the illumination level. The camera should be capable of capturing both color and B &W (Black & White)
video with minimum Color Illumination of 0.7 lux for Color and upto 0.08 Lux for B & W, for deliverance of
video captured in very low luminous environment/conditions.-
6 ASPECT RATIO:
Aspect ratio should be 16:9.
7
BACK LIGHT COMPENSATION :The camera shall have smart BLC to compensate the image without
compromising the dynamic range.

8 WIDE DYNAMIC RANGE: For harsh lighting, the camera should have Wide Dynamic Range functionality to
resolve details in the scene s brightest areas to get a clear picture.

9 AUTO IRIS : Camera should have Auto Iris to work seamlessly in all varying light conditions.

10 ONVIF (Open Network video Interface Forum)Camera model proposed for the tender should be conforming
to ONVIF standards to ensure integration with third party management systems & video network devices.

11 NETWORK CONNECTIVITY:
 10/100 Base-T, auto-sensing, half/full duplex,RJ45,

 PoE IEEE 802.3af compliant.

 Access to be password protected.

 Should support IP filtering

 Should provide integrated support to IPv4, IPv6, TCP, DHCP, HTTP, UPnP, DDNS, IGMP, HTTPS,
SMTP, FTP and 802.1X.

12 CAMERA PROCESSOR:

 The camera processor shall have at least 256MB of RAM and 128MB of flash memory.

 Should efficiently handle minimum three (3) independent H.264 streams.

FAIL SAFE:

13 If the controlling Server equipped with the remote monitoring software fails, then the camera Encoder s built
in web server should enable any PC on the network to monitor camera for mission critical application. No
unique or proprietary client software shall be required for viewing or controlling the camera.

14 ALARMS:

Alarm Input/ Output 2/1. Event based alarm generation (http based) :

Tamperproof alarm which includes spray on camera, out of focus, blocking, camera shift, etc

15 CAMERA LENS:

 Megapixel Varifocal lens- minimum 3 MM to 8 MM.

 Camera should support hassle free replacement of existing lens with higher configuration varifocal
lens in future.

16 Housing Outdoor to be confirming to (IP 66). Camera can also be with IP66 casing with standard mounting
bracket.

17 CERTIFICATIONS:

EN or UL and FCC
18 OPERATING TEMPERATURE: -0°C to +50°C

19 HUMIDITY: 80% RH

20 IMAGE SETTING:

 Adjustable image size, quality and bit rate .

 Should support digital zooming.

 Should support both Constant bit rate and Variable bit rate configuration for bandwidth optimization.

 Time Stamp & text caption overlay

 Configurable brightness, contrast, saturation, sharpness and white balance

 AGC,AWB,AES

 Automatic, manual or scheduled day/night mode

 Support Privacy masks

21 LICENSE FEES:

There should not be any license fees for accessing camera including the firmware up gradation.

22 NTP:

Shall have Embedded real-time clock and shall have built in support for Network

Time Protocol (NTP)

2. CAMERA HOUSING:

1 Housing should be Aluminum di-cast. Powder coated, Mounting bracket with provision to accommodate
cat6 cable internally, without hanging out.

2 The Camera Housing should be conforming to IP 66 rating. The supporting certificate to be attached.