0% found this document useful (0 votes)
1K views1 page

Operating Instructions: Modular Time Switch

This document provides operating instructions for a modular time switch. It describes the installation, programming, hour updating, and manual mode of the time switch. It also lists the technical specifications, including the supply voltage, switching capability, power consumption, accuracy, battery life, dial types, minimum functioning times, temperature range, and protection levels. Dimensions of the time switch are also provided.

Uploaded by

wrpinacate
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

Operating Instructions: Modular Time Switch

This document provides operating instructions for a modular time switch. It describes the installation, programming, hour updating, and manual mode of the time switch. It also lists the technical specifications, including the supply voltage, switching capability, power consumption, accuracy, battery life, dial types, minimum functioning times, temperature range, and protection levels. Dimensions of the time switch are also provided.

Uploaded by

wrpinacate
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

OPERATING INSTRUCTIONS

MODULAR TIME SWITCH uno


INDEX

MANUAL MODE

PROGRAMMING
DIAL

DESCRIPTION
The UNO time switch controls any electrical installation by means of daily or weekly
programs.

INSTALLATION
ATTENTION: Electrical devices must be installed and assembled by an authorized
installer. They should be installed in switchboard cabinets made of 35mm symmetric
sections in accordance with EN 50 022.
VERY IMPORTANT: The switch is protected internally against interference by a
safety device. However, particularly strong electromagnetic fields may alter its
operation.
Such interference can be avoided by adhering to the following recommendations
during installation:
- The device should not be installed near inductive loads (motors, transformers,
contactors, etc.).
- A separate power line is recommended (equipped with a network filter if
necessary).
- Inductive loads should be equipped with interference suppressors (varistor, RC
filter).
If the timer switch is to be used in combination with other devices in an installation, it is
necessary to verify that no parasitic disturbances will be caused by the group.
CONNECTION: Connection scheme
L 1
UNO
M

N 2

PROGRAMMING:
Take over all the pins to the right. Take over to the left the pins corresponding to the
desired times of connection, in which the contact 1-2 will be closed.
OFF
6
ON
5
OFF

HOUR UPDATING:
Turn the dial until the index is on the current time.

MANUAL MODE:
2 positions :
  Automatic functioning
Ι Permanent connection

TECHNICAL SPECIFICATIONS:
Supply voltage: Follow the indications
Switching capability: 16 (4) A / 250 V~
Power consumption: 0.5 W
Operating accuracy: ± 1 sec./day at 22ºC
Power reserve (QRD, QRS): 100 hours
Type of dial: Daily: 96 pins
Weekly: 84 pins
Minimum time of functioning: Daily: 15 minutes
Weekly: 2 hours
Functioning temperature: -10ºC to +50ºC
Protection category: IP 20 in accordance with
EN 60529
Protection class II in accordance with EN 60335
under correct assembling conditions

DIMENSIONS: 66

60 17.5

45 90

ATTENTION
This unit incorporates a battery containing contents that can be harmful to the
environment. Please do not throw it away without removing the battery and putting it
in the proper container for recycled batteries or to send the complete unit back to the
factory.
A016.40.42236

ORBIS TECNOLOGÍA ELÉCTRICA, S.A.


Lérida, 61 E–28020 MADRID
Teléfono:+ 34 91 5672277; Fax:+34 91 5714006
E-mail: [email protected] http://www.orbis.es