0% found this document useful (0 votes)
151 views5 pages

Seismic Design For Ordinary Concentrically Braced Frames Based On CBC 07 & AISC 341-05

This document provides a seismic design summary for concentrically braced frames (CBFs) based on CBC 07 and AISC 341-05 standards. It analyzes the design of HSS6X6X5/8 tubular braces and W14X370 wide flange braces. Calculations are shown to check limiting width-thickness ratios, slenderness ratios, required factored loads, connection design forces, weld sizes, and tension/compression/shear capacities of the brace and connection elements. The design is determined to be adequate and in compliance with standards.

Uploaded by

xuankhoi doanvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views5 pages

Seismic Design For Ordinary Concentrically Braced Frames Based On CBC 07 & AISC 341-05

This document provides a seismic design summary for concentrically braced frames (CBFs) based on CBC 07 and AISC 341-05 standards. It analyzes the design of HSS6X6X5/8 tubular braces and W14X370 wide flange braces. Calculations are shown to check limiting width-thickness ratios, slenderness ratios, required factored loads, connection design forces, weld sizes, and tension/compression/shear capacities of the brace and connection elements. The design is determined to be adequate and in compliance with standards.

Uploaded by

xuankhoi doanvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE: REVIEW BY :
Seismic Design for Ordinary Concentrically Braced Frames Based on CBC 07 & AISC 341-05

INPUT DATA & DESIGN SUMMARY


BRACE SECTION (Tube or Pipe) = > HSS6X6X5/8 Tube A rmin t h
BRACE AXIAL LOAD AT SERVICE LEVEL D= 20 kips 11.70 2.17 0.58 6.00
L= 10 kips
BRACE AXIAL LOAD AT HORIZ. SEISMIC QE = 50 kips (ASCE 7-05 12.4.2.1)
SEISMIC PARAMETER SDS = 0.533 (ASCE 7-05 11.4.4) THE DESIGN IS ADEQUATE.
UNBRACED LENGTH OF THE BRACE l= 18 ft
BUILDING LIMITATION FOR SDC D or E H= 28 ft (< 35 ft, ASCE 7-05 Tab. 12.2-1)
REQUIRED CONNECTION = > ( 5/8 in Gusset Plate with 14 in Length, 4 leg, 5/16 in Fillet Weld. Cover Plate 3/4 x 5 at Each Sides.)
CBC 07 Chapter A (DSA only) APPLY? == > Yes

CHECK LIMITING WIDTH THICKNESS RATIO lps FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
D / t = 0.044 Es / Fy = 27.74 , for Pipe
( D / t = 1300 / Fy for AISC-Seismic 97, Tab. 1-9-1) > Actual [Satisfactory]
h / t = 0.64 (Es / Fy)0.5 = 16.07 , for Tube
[ h / t = 110 / (Fy)0.5 for AISC-Seismic 97, Tab. 1-9-1]

Where Fy = 46 ksi
Es = 29000 ksi

CHECK LIMITING SLENDERNESS RATIO FOR V OR INVERTED-V CONFIGURATIONS (AISC 341-05 Sec. 14.2)
4 (Es / Fy)0.5 = 100.4 > Kl/r= 99.5 [Satisfactory]
[ 720 / (Fy)0.5 for AISC-Seismic 97, Sec. 14.2]
Where K = 1.0

DETERMINE FACTORED DESIGN LOADS TO WITHSTAND LIMITED INELASTIC DEFORMATIONS (AISC 341-05 Sec.14.1)
Put = 0.9D - (Cd / I ) QE - 0.2SDSD = -146.6 kips (Tension, ASCE 7-05 Sec. 12.8.6)
Puc = 1.2D + f1L + (Cd / I ) QE + 0.2SDSD = 193.6 kips (Compression Governs, ASCE 7-05 Sec. 12.8.6)
Where Cd = 3 1/4 (ASCE 7-05 Tab. 12.2-1)
I= 1 (CBC Tab.1604.5)
f1 = 0.5 (CBC 1605.4)

CHECK DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


fcPn = fcAgFcr = 248.75 kips > Puc [Satisfactory]
Where fc = 0.9
Fe = p2 E / (KL / r)2 = 28.8906 ksi (0.658(Fy/Fe) )Fy = 23.62 kis, for l c ≤ 4.71
lc = (KL / r) (Fy / E) = 0.5
Fcr = { 0.877 Fe = kis, for l c > 4.71
3.96 N/A
DETERMINE CONNECTION DESIGN FORCE (AISC 341-05 Sec. 14.4)
Put = Min(RyFyAg , W0Pu) = 387.26 kips
Where Ry = 1.4 (AISC 341-05 Tab. I-6-1) ( 1.6 for Pipe)
W0 =
2
DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)
> wMIN = 0.1875 in
w= 5/16 in
< wMAX = 0.4375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(4) f Fw (0.707 w)]
= 387.26 / [(4) 0.75 (0.6x70)(0.707x5/16)] =
13.91 in
( USE 14 in )
CHECK DESIGN SHEAR RUPTURE OF SLOTTED BRACE (AISC 360-05 Sec.J4.2)
fPn = f(0.6Fu)Anv = 849.19 kips > Put
Where f = 0.75 [Satisfactory]
Fu = 58 ksi (LRFD Tab.1-4, Pg. 1-21)
Anv = 4 t L = 4 x 0.581 x 14 = 32.54 in2
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
tg = 5/8 in
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 Sec.J4.2)
fPn = f(0.6Fu)Anu = 456.75 kips > Put [Satisfactory]
Where f = 0.75
Fu = 58 ksi (A36 Steel)
Anu = 2 tg L = 2 x 5/8 x 14 = 17.50 in2
(cont'd)
CHECK TENSION CAPACITY AT SLOTTED BRACE (AISC 360-05 D.2 b)
fPn = f Rt Fu Ae = 513.94 kips > Put [Satisfactory]
Where f = 0.75
Fu = 58 ksi (AISC 13th Tab.2-3)
x = 3 h / 8 = 2.25 , for Tube (HSS Specification 2.1-4)
D / p = 1.91 , for Pipe (HSS Specification 2.1-3)
U = MIN( 1 - x / L , 0.9 ) = 0.84 ,(AISC 360-05 Tab. D3.1.)
An = Ag - 2 (tg + 1/8) t = 10.83 in2
Ae = U An = 9.09 in2
Rt = 1.3 (AISC 341-05 Tab. I-6-1)
Try Cover Plate 3/4 x 5 , at Each Sides.

Region x 0.5 An xA
HSS 2.25 5.41 12.18 x = 24.84 / 9.16 = 2.71
Cover Plate 3.38 3.75 12.66 U = MIN( 1 - x / L , 0.9 ) = 0.81
S 9.16 24.84 An = 10.83 + 7.50 = 18.33 in2
Ae = U An = 14.78 in2
Thus, fPn = f Rt Fu Ae = 771.52 kips > Put [Satisfactory]
Where Fu = 58 ksi, use plate value
Rt = 1.2 (AISC 341-05 Tab. I-6-1)
Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE: REVIEW BY :
Seismic Design for Ordinary Concentrically Braced Frames Based on CBC 07 & AISC 341-05

INPUT DATA & DESIGN SUMMARY


WF BRACE SECTION = > W14X370 == > A ry k d bf
BRACE AXIAL LOAD AT SERVICE LEVEL D = 100 kips 109.00 4.27 3.26 17.90 16.50
L= 100 kips tw tf
BRACE AXIAL LOAD AT HORIZ. SEISMIC QE = 100 kips (ASCE 7-05 12.4.2.1) 1.66 2.66
SEISMIC PARAMETER SDS = 0.533 (ASCE 7-05 11.4.4)
BRACE YIELD STRESS Fy = 50 ksi THE DESIGN IS ADEQUATE.
UNBRACED LENGTH OF THE BRACE l = 31.4 ft
BUILDING LIMITATION FOR SDC D or E H= 35 ft (< 35 ft, ASCE 7-05 Tab. 12.2-1)
REQUIRED CONNECTION = > ( 2 in Gusset Plate with 8 in Length, 8 leg, 3/4 in Fillet Weld. .)
CBC 07 Chapter A (DSA only) APPLY? == > Yes

CHECK LIMITING WIDTH THICKNESS RATIO lps FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
bf / tf = 0.30 (Es / Fy)0.5 = 7.22 > Actual [Satisfactory]
( bf / tf = 52 / (Fy)0.5 for AISC-Seismic 97, Tab. 1-9-1)

Where Es = 29000 ksi

CHECK LIMITING SLENDERNESS RATIO FOR V OR INVERTED-V CONFIGURATIONS (AISC 341-05 Sec. 14.2)
4 (Es / Fy)0.5 = 96.3 > Kl/r= 88.2 [Satisfactory]
[ 720 / (Fy)0.5 for AISC-Seismic 97, Sec. 14.2]
Where K = 1.0

DETERMINE FACTORED DESIGN LOADS TO WITHSTAND LIMITED INELASTIC DEFORMATIONS (AISC 341-05 Sec.14.1)
Put = 0.9D - (Cd / I ) QE - 0.2SDSD = -245.7 kips (Tension, ASCE 7-05 Sec. 12.8.6)
Puc = 1.2D + f1L + (Cd / I ) QE + 0.2SDSD = 505.7 kips (Compression Governs, ASCE 7-05 Sec. 12.8.6)
Where Cd = 3 1/4 (ASCE 7-05 Tab. 12.2-1)
I= 1 (CBC Tab.1604.5)
f1 = 0.5 (CBC 1605.4)

CHECK DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


fcPn = fcAgFcr = 2777.76 kips > Puc [Satisfactory]
Where fc = 0.9
Fe = p2 E / (KL / r)2 = 36.8046 ksi (0.658(Fy/Fe) )Fy = 28.32 kis, for l c ≤ 4.71
lc = (KL / r) (Fy / E) 0.5
=
Fcr = { 0.877 Fe = kis, for l c > 4.71
3.66 N/A

DETERMINE CONNECTION DESIGN FORCE (AISC 341-05 Sec. 14.4)


Put = Min(RyFyAg , W0Pu) = 1011.32 kips (Tension)
Where Ry = 1.1 (AISC Seismic 02 & 97 Tab. I-6-1)
W0 =
2
DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)
> wMIN = 0.3125 in
w= 3/4 in
< wMAX = 0.9375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(8) f Fw (0.707 w)]
= 1011.32 / [(8) 0.75 (0.6x70)(0.707x3/4)] =
7.57 in
( USE 8 in )
CHECK SHEAR RUPTURE OF SLOTTED CON. PLATES (AISC 360-05 Sec.J4.2)
fPn = f(0.6Fu)Anv = 1386.43 kips > Put
Where f = 0.75 [Satisfactory]
Fu = 58 ksi (A36 Steel)
Anv = 4 t L = 4 x 1.66 x 8 = 53.12 in2
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
tg = 2 in, Center with Column Web.
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 Sec.J4.2)
fPn = f(0.6Fu)Anu = 1670.40 kips > Put [Satisfactory]
Where f = 0.75
Fu = 58 ksi (A36 Steel)
Anu = 4 tg L = 4 x 2 x 8 = 64.00 in2

You might also like