0% found this document useful (0 votes)
66 views1 page

Ups Kva High

1. The document describes a medical technology company that imports medical equipment and supplies. 2. It lists specifications for several uninterruptible power supply (UPS) models ranging from 20kVA to 200kVA, including input/output voltage, frequency, waveform, transfer time, and battery specifications. 3. Contact information is provided for the company in Benghazi, Libya.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views1 page

Ups Kva High

1. The document describes a medical technology company that imports medical equipment and supplies. 2. It lists specifications for several uninterruptible power supply (UPS) models ranging from 20kVA to 200kVA, including input/output voltage, frequency, waveform, transfer time, and battery specifications. 3. Contact information is provided for the company in Benghazi, Libya.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

‫شركة التكنولوجيا الطبية الستيراد المعدات الطبية ومستلزماتها‬

TS3320 TS3330 TS3340 TS3360 TS3380 TS33100 TS33120 TS33160 TS33200


Model
20K 30K 40K 60K 80K 100K 120K 160K 200K
20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA
Rating Power
16KW 24KW 32KW 48KW 64KW 80KW 96KW 128KW 160KW
Input system 3 Phases + N & earth ground
Voltage range 380/400/415}25%
Input
Power factor ≥0.99
Frequency 50/60}10%5% optional
Output system 3 Phases + N & earth ground
Rated voltage L-N:220/230/240}1%, L-L:380/400/415}1%,
Power factor 0.8
Voltage
±2%
precision
Voltage
THD≤2% (linear load)
distortion
Output Output
Pure Sinewave
waveform
Output
50/60}0.2 (battery mode)
frequency
Inverter overload
capacity 125% load for 10mins, 150% load for 1 min
(Utility power, 25Co)

Transfer time 0ms


Crest factor 3:01
LCD Display LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
LED Status
Utility power; Battery discharge; Inverter On
Indicator
DISPLAY/ External
INTERFAC Communication MODBUS/RS485 and dry contact (RS232 and SNMP adapter are optional)
E
Display Touch screen + LED
software Windows XP/ 2003 and later version; Linux; Unix
Optional SNMP Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device

Batteries voltage 348 (360 setting) 384(348/360/372 setting)


Battery Type Sealed maintenance-free lead –acid battery / Gel Battery / NiCd
Battery
Backup Time Full load ≥ 5min (Standard)

Battery quantity 32 32 (29,30,31)

Temperature 0 ~ 40℃

Altitude <1000m
General Efficiency Line: ≥ 94%
Alarm Overload, abnormal AC input, low battery, UPS failure
Noise (dB) <55 < 60 - 65
Protection Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
L*W*H (mm) 656×405×817 821x432x1159 975×554×1286 1050×705×1646
Weight (kg) 145 195 280 365 475 580 650 740 - 80

Price ( lyd) 47,000 58,000 71,000 85,000 111,000 133,000 155,000 177,000 197,000

‫شركة التكنولوجيا الطبية الستيراد المعدات الطبية ومستلزماتها‬


‫بنغازي – ليبيا‬- ‫ بن يونس‬091 966 6093 / 092 793 6177 / 091 348 1620