Ut501/Ut502 Operating Manual: Title
Ut501/Ut502 Operating Manual: Title
Ut501/Ut502 Operating Manual: Title
Table of Contents
Title Page
Introduction 4
Safety Information 6
Key Functions 14
Rotary Switch 15
Measurement Operation 16
A. Measuring Voltages 16
Maintenance 21
A. General Service 21
Specifications 25
Physical Specifications 26
General Specifications 27
Feature Summary 27
A. Voltage Measurement 28
List of Tables
Table Title Page
1. Unpacking Inspection 5
4. Key Description 14
List of Figures
Figure Title Page
1. The Meter Front Structure 12
2. Voltages Measurement 16
4. Battery Replacement 23
3
UT501/UT502 OPERATING MANUAL
Introduction
Uni-Trend Model UT501 and UT502 insulation resistance tester (hereafter, "the Meter")
4
UT501/UT502 OPERATING MANUAL
6 Strap 1 piece
In the event you find any missing or damage, please contact your dealer immediately.
5
UT501/UT502 OPERATING MANUAL
Safety Information
This Meter complies with the standards IEC61010 -1 safety measurement requirement:
in pollution degree 2, overvoltage category (CAT. III 600V, CAT.II 1000V) and double
insulation.
CAT II: Local level, appliance, portable equipment etc., with smaller transient voltage
CAT III: Distribution level, fixed installation, with smaller transient over voltages than
CAT. IV
Use the Meter only as specified in this operating manual, otherwise the protection
Danger identifies conditions and actions that pose hazard(s) to the user.
Caution identifies conditions and actions that may damage the Meter and carrying
International electrical symbols used on the Meter and in this Operating Manual are
7
UT501/UT502 OPERATING MANUAL
Danger
When using the test leads, keep your figures away from the lead contacts.
under test.
8
UT501/UT502 OPERATING MANUAL
Warning
Do not use the Meter if it is damaged or metal part is exposed. Look for
Be careful when working above 30V rms, 46.7V ac rms and 70V DC. Such
Place test leads in proper input terminals. Make sure all the test leads
Make sure the Meter is turned off when opening the battery compartment.
Follow the operating manual all the time when using the Meter and keep
Caution
When performing resistance tests, remove all power from the circuit to
When servicing the Meter, use only the same model number or identical
empty condition. Take the battery out from the Meter if it is not used
10
UT501/UT502 OPERATING MANUAL
11
UT501/UT502 OPERATING MANUAL
a.UT501 b.UT502
Figure 1. The Meter Front Structure
12
UT501/UT502 OPERATING MANUAL
5 LCD
9 Rotary switch
13
UT501/UT502 OPERATING MANUAL
Key Functions
Table 4. Key Description
HOLD Press once to turn the data hold on, is shown on the display.
14
UT501/UT502 OPERATING MANUAL
Rotary Switch
Table 5. Rotary Switch Description
resistance measurement.
resistance measurement.
15
UT501/UT502 OPERATING MANUAL
Measurement Operation
Below section explains how to make measurements.
A. Measuring Voltages
a.UT501 b.UT502
Figure 2. Voltages Measurement
16
UT501/UT502 OPERATING MANUAL
Catuion
To avoid harm to you or damages to the Meter from electric shock, do not
between the testing leads and the circuit under test and remove testing leads away
2. Insert the red test lead into the V terminal and the black test lead into the G terminal.
a.UT501 b.UT502
When measuring insulation resistance, please must separate the two test leads.
When performing insulation resistance tests, remove all power from the circuit
Do not short circuit two test leads under high voltage status.
When the measurement is completed, donít touch the circuit as the circuit has
Don't touch the test leads even after it has been removed from the circuit until
To measure insulation resistance, set up the Meter as Figure 3 and do the following:
19
UT501/UT502 OPERATING MANUAL
Turn the rotary switch to one of these position 250V / 500V / 1000V / 2500V.
1. When performing insulation resistance tests, remove all power from the circuit
2. Insert the red test lead into the LINE terminal and the black test lead into
EARTH terminal.
3. Connect the red and black alligator clip to the circuit to be measured, positive
Continuous Measurement
1. Turn the rotary switch to one of these position 250V / 500V / 1000V / 2500V
Maintenance
This section provides basic maintenance information including battery replacement
instruction.
Warning
Do not attempt to repair or service your Meter unless you are qualified to do
so and have the relevant calibration, performance test, and service information.
A. General Service
Periodically wipe the case with a damp cloth and mild detergent. Do not use
abrasives or solvents.
To clean the terminals with cotton bar with detergent, as dirt or moisture in
Take out the battery when it is not using for a long time.
22
UT501/UT502 OPERATING MANUAL
Danger
Make sure the battery compartment is closed before using the Meter
Turn the Meter to OFF and remove all connections from the terminals.
Remove the screw from the battery compartment, and separate the battery
Rejoin the case bottom and battery compartment, and reinstall the screw.
24
UT501/UT502 OPERATING MANUAL
Specifications
Certification
standard
25
UT501/UT502 OPERATING MANUAL
Physical Specifications
26
UT501/UT502 OPERATING MANUAL
General Specifications
Over loading UT501:
Feature Summary
Display Backlight Bright backlight for clear readings in poorly lighted areas.
A. Voltage Measurement
DC Voltage AC Voltage
Measurement Range 30 ~ 1000V 30V~750V (50/60Hz)
Resolution 1V
Accuracy (2%+3)
28
UT501/UT502 OPERATING MANUAL
3M ~2000M
29
UT501/UT502 OPERATING MANUAL
Display Range (less than 3M, buzzer beeps (less than 5M, buzzer beeps (less than 25M, buzzer beeps
3M to 99.9M : (3%+1)
** END **
30
UT501/UT502 OPERATING MANUAL
32