PT EDMI INDONESIA

Rukan Tendean Square No.8 Jl. Wolter Monginsidi 122-124 Jakarta 12170 -INDONESIA
Tel : +62 21 72780868, Fax : +62 21 72780865
Email : [email protected]

Mk6E
Advanced Three Phase
Electronic Revenue Meter
Genius Series - Class 0.2S

PRODUCT INFORMATION

The Mk6E is an enhanced upgrade of the Mk6 meter,


built with a higher class accuracy of 0.2S, catering to
the high-end markets. The Mk6E is a high-precision
meter created for generation and transmission
applications, as well as for revenue metering at
high-end consumer facilities.

KEY FEATURES

AMI READY HIGH LARGE LARGE MEASURE UPGRADEABLE TAMPER SCRIPT


ACCURACY DATA STORAGE LCD DISPLAY EVERYTHING PROOF EXTENSIONS
Mk6E Genius Series - Class 0,2S

Advanced Three Phase


Electronic Revenue Meter
SPECIFICATIONS

Accuracy Quality of Supply Features Humidity range LCD Display


• Class 0.2S (IEC62053-23) • THD • 0 to 95% non condensing • 16 character by 2 line
• Unbalance alphanumeric display
Time Keeping
• Fundamental Voltage, Current and • Programmable units, multipliers
Voltage • Accuracy: 0.5s/day (over full
Watt measurement and leading zeros
• Nominal - 57.7/100V - 230/400V temperature range)
• Harmonics (up to the 50th) • Up to 64 user definable
(phase to neutral) • Backup time - 2 years
• Sag / Swell screen displays
• Burden - <10VA / phase @ Vn (3 without power
- 5 cycle resolution • Displays any available
phase) • Backup type - optional lithium meter parameter
• Frequency 45-65 Hz - Records time/date/phase/duration battery 700/1200mAh, 3.6V and
/worst excursion • Optional 20 character by 4 line
SuperCap (single/dual)
Current - Programmable trigger levels
alphanumeric display
• Battery shelf life of 20 plus years
• CT Range - 1/4A and 5/10A Extensions for Customer
Pulsing IO • Mains synchronised or internal
• Short time over-current - 20 times
crystal time keeping. Mains Applications: standard or to
the Imax for 0.5 seconds • 2 inputs + common ground order
synchronised reverts to internal
• Burden - <0.5VA/phase • 2 outputs + common ground
crystal on loss of all phase volts Mk6E GENIUS plus®meter
• 6 outputs + common ground continues the successful concept
Auxiliary Supply Options Time Of Use
• 110/240V BOSFET outputs of meter “Extensions” introduced
• 240V, 110V (other voltages available (IEC 62053-31 class A and B) • 8 rates plus unified rate in the original Mk6 Genius® Using
on special order) “EziScript”, complex register
• Up to 16 inputs or outputs via • Up to 12 separate import and
Measurement Modes optional extended IO cards export registers manipulations can be performed
• Up to 200 programmable allowing sophisticated meter
• 3 phase 3 wire (2 element) Communications Ports functions. New Extensions are
special days
• 3 phase 4 wire (3 element) • Local - ANSI type 2 optical or constantly under development,
• Daily, Weekly, Monthly,
Measured Energy Values FLAGTM (IEC 61107) contact us to find out the
Yearly, Special
• Remote - Isolated RS485, RS232 latest updates.
• Import/Export Wh, varh and VAh • 13 or more previous periods
or both Some examples of currently available
• Absolute Wh, varh and VAh • Block or Rolling Maximum Demand
Extensions are:
• 4 quadrant Wh, varh and VAh Communications Features • Time of Maximum Demand
• ANSI Type 2 Optical • Send SMS at percentage of
• Phase A, B, C or Total Load Survey / Profile maximum demand, or equipment
• IEC 61107 / IEC 62056-21
Other Measured and Displayed • NEM compliant failure alarm
+ VDEW 2.0 extensions
Values • Over 900 kilobytes of fl ash data • Maximum demand control of loads
• RS232 (RTS/CTS and DTR/DCD)
• Power: W, var, VA storage space. via pulsing outputs
• RS485 (2 or 4 wire multidrop)
• True RMS Voltage (3 phase) ~ 3100 day-channel capacity at 30 • Time Of Use history etc
• SCADA
• True RMS Current (3 phase) minute intervals
• Modems Software
• Power factor ~ 1875 day capacity at 30 minute
(PSTN/GPRS/GSM/CDMA) • EziView Windows® software
intervals / 2 channels
• Frequency • MV90TM (optional), can be used for
~ 520 day capacity at 15 minute
• Phasor angles • MODBUS® programming and reading
intervals / 3 channels
• UDP/IP over PPP/GPRS the meter
• Up to 50 channels
• DNP3 • EziView also allows offline
• Interval programmable from 1 configuration of tariff programs
• IEC 870-5-102 second to 1 month and all meter parameters, for
• Optional internal modem • Multiple independent surveys later upload
power supply
• Energy, instantaneous readings,
pulsing inputs, average/min Dimensions
Temperature Range
/max readings • 262mm (L) 175 mm (W) 93mm (D)
• Operating -25 to +60°C
• Storage -25 to +80°C

EDMI Limited
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 Fax: +65 6756 0125
Email: [email protected] | [email protected] www.edmi-meters.com

Copyright © 2010 EDMI Limited. All Rights Reserved. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.