AMM - IGO - A318/A319/A320/A321 REV DATE: Aug 01/2021 Tail Number - MSN - FSN: VT-ILN - 10151 - 431
AMM - IGO - A318/A319/A320/A321 REV DATE: Aug 01/2021 Tail Number - MSN - FSN: VT-ILN - 10151 - 431
AMM - IGO - A318/A319/A320/A321 REV DATE: Aug 01/2021 Tail Number - MSN - FSN: VT-ILN - 10151 - 431
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE
SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT
FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL
MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR MAINTENANCE WORK WHILE YOU
DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS
USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN
THE PNEUMATIC SYSTEM AND INJURY CAN OCCUR.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
QT
REFERENCE DESIGNATION
Y
No specific AR WARNING NOTICE(S)
No specific Torque wrench: range to between 91 and 99 lbf.in (1.03 and 1.12
m.daN)
B. Consumable Materials
REFERENCE DESIGNATION
CP2442 engine oil
D. Expendable Parts
E. Referenced Information
REFERENCE DESIGNATION
Ref. 71-13-00-010-803-A Opening of the Fan Cowl Doors
Ref. 71-13-00-410-803-A Closing of the Fan Cowl Doors
Ref. 73-29-00-740-802-A Actuators Test (Menu Mode)
Ref. Fig. Starter Air Valve
3. Job Set-up
SUBTASK 80-11-15-941-051-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less
than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize
FADEC 1(2).
(3) On the overhead control and indicator panel 25VU, on the Auxiliary Power Unit (APU) section:
(a) Make sure that the APU MASTER SW pushbutton is released.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the
APU.
SUBTASK 80-11-15-010-051-A
B. Get Access
(1) Make sure that the fan cowl doors are open Ref. AMM TASK 71-13-00-010-803:
(a) FOR 4020KM1 (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR 4020KM2 (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
4. Procedure
Ref. Fig. Starter Air Valve
SUBTASK 80-11-15-420-050-A
A. Installation of the Starter Air Valve (SAV)
(1) Remove all the COVER - PROTECTION and CAP - PROTECTION from the openings, tubes,
hoses and connectors.
(2) Make sure that the mating surfaces are clean and clear of unwanted materials.
(3) Lubricate the nuts and V-band clamps.
NOTE: Align the sign with the A face of the starter air valve (SAV).
(5) Install a new PIPC-CSN(80-11-15-01 ITEM 030) SEAL (13) between the SAV (1) and the
pneumatic air starter (9).
(6) Install the V-band clamp (8) to attach the SAV (1) on the pneumatic air starter (9).
(7) Tighten the nut (7) on the V-band clamp (8) to attach the SAV (1) on the pneumatic air starter (9)
with your hand.
(8) TORQUE the nut (7) to between 91 and 99 lbf.in (1.03 and 1.12 m.daN).
(9) Install a new IPC-CSN(80-12-49-01 ITEM 090) SEAL (14) between the SAV (1) and the starter
air duct (3).
(10) Install the V-band clamp (5) to attach the starter air duct (3) on the SAV (1).
(11) Install the tightener (6) in the locked position on the V-band clamp (5).
(12) Tighten the nut (4) on the tightener (6).
(13) TORQUE the nut (4) to between 91 and 99 lbf.in (1.03 and 1.12 m.daN).
(14) Connection of the electrical connectors
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE
YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE
ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(a) Connect the two HJ6A harness electrical connectors, the 1.18 in. (30 mm) diameter
connector (2) to the socket (11) and the 0.98 in. (25 mm) diameter connector (10) to the
socket (12) of the SAV (1).
SUBTASK 80-11-15-710-050-A
B. Test
(1) Do the actuators test Ref. AMM TASK 73-29-00-740-802.
5. Close-up
SUBTASK 80-11-15-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors Ref. AMM TASK 71-13-00-410-803:
(a) FOR 4020KM1 (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR 4020KM2 (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
(3) Remove the WARNING NOTICE(S).