0 - PC8000-6-D - SM#12046 (Pelambres)
0 - PC8000-6-D - SM#12046 (Pelambres)
0 - PC8000-6-D - SM#12046 (Pelambres)
05
SERVICE
MANUAL
PC8000
MACHINE MODEL SERIAL NUMBER
This service manual may contain attachments and optional equipment that are not
available in your area.
Please consult your local Komatsu distributor for those items you may require.
CONTENTS
TABLE OF CONTENTS
00 Safety - Foreword
01 Technical DATA (Leaflet)
02 Assembly PROCEDURE (Brochure)
Section
1. Main assembly groups
2. Drive
3. Hydraulic oil tank
4. Hydraulic oil cooling
5. Controlling
6. Components
7. Main hydraulic pumps and pump regulation
8. Operating hydraulic
9. Hydraulic track tensioning system
10. Hydraulic operated access ladder
11. Central refilling system
12. Hints for the hydraulic circuit diagram
13. Hints for the electric circuit diagram
14. Electronic Control System - ECS
15. Lubrication Systems
APPENDIX
SAFETY
SAFETY NOTICE
GENERAL PRECAUTIONS
Mistakes in operation are extremely dangerous. Read the OPERATION & MAINTENANCE
MANUAL carefully BEFORE operating the machine.
1. Before carrying out any greasing or repairs, read all the precautions given on the decals
which are fixed to the machine.
2. When carrying out any operation, always wear safety shoes and helmet. Do not wear
loose work clothes, or clothes with buttons missing.
• Always wear safety glasses when hitting parts with a hammer.
• Always wear safety glasses when grinding parts with a grinder, etc.
continued
00-1
SAFTEY SAFTEY NOTICE
Cont'd:
GENERAL PRECAUTIONS
3. If welding repairs are needed, always have a trained, experienced welder carry out the
work. When carrying out welding work, always wear welding gloves, apron, glasses, cap
and other clothes suited for welding work.
4. When carrying out any operation with two or more workers, always agree on the
operating procedure before starting. Always inform your fellow workers before starting
any step of the operation. Before starting work, hang UNDER REPAIR signs on the
controls in the operator's compartment.
5. Keep all tools in good condition and learn the correct way to use them.
6. Decide a place in the repair workshop to keep tools and removed parts. Always keep the
tools and parts in their correct places. Always keep the work area clean and make sure
that there is no dirt or oil on the floor. Smoke only in the areas provided for smoking.
Never smoke while working.
7. Before adding oil or making repairs, park the machine on hard, level ground, and block
the wheels or tracks to prevent the machine from moving.
8. Before starting work, lower bucket, hammer or any other work equipment to the ground.
If this is not possible, insert the safety pin or use blocks to prevent the work equipment
from falling. In addition, be sure to lock all the control levers and hang warning signs on
them.
9. When disassembling or assembling, support the machine with blocks, jacks or stands
before starting work.
10. Remove all mud and oil from the steps or other places used to get on and off the machine.
Always use the handrails, ladders or steps when getting on or off the machine. Never
jump on or off the machine. If it is impossible to use the handrails, ladders or steps, use a
stand to provide safe footing.
11. When removing the oil filler cap, drain plug or hydraulic pressure measuring plugs,
loosen them slowly to prevent the oil from spurting out.
Before disconnecting or removing components of the oil, water or air circuits, first
remove the pressure completely from the circuit.
12. The water and oil in the circuits are hot when the engine is stopped, so be careful not to
get burned.
Wait for the oil and water to cool before carrying out work on the oil or water circuits.
continued
00-2
SAFTEY SAFTEY NOTICE
Cont'd:
PRECAUTIONS DURING WORK
13. Before starting work, remove the leads from the battery. ALWAYS remove the lead from
the negative (-) terminal first.
14. When raising heavy components, use a hoist or crane.
Check that the wire rope, chains and hooks are free from damage.
Always use lifting equipment which has ample capacity.
Install the lifting equipment at the correct places. Use a hoist or crane and operate slowly
to prevent the component from hitting any other part. Do not work with any part still
raised by the hoist or crane.
15. When removing covers which are under internal pressure or under pressure from a spring,
always leave two bolts in position on opposite sides. Slowly release the pressure, then
slowly loosen the bolts to remove.
16. When removing components, be careful not to break or damage the wiring, Damaged
wiring may cause electrical fires.
17. When removing piping, stop the fuel or oil from spilling out. If any fuel or oil drips on to
the floor, wipe it up immediately. Fuel or oil on the floor can cause you to slip, or can
even start fires.
18. As a general rule, do not use gasoline to wash parts.
19. Be sure to assemble all parts again in their original places. Replace any damaged part
with new parts.
• When installing hoses and wires, be sure that they will not be damaged by contact
with other parts when the machine is being operated.
20. When installing high pressure hoses, make sure that they are not twisted. Damaged tubes
are dangerous, so be extremely careful when installing tubes for high pressure circuits.
Also check that connecting parts are correctly installed.
21. When assembling or installing parts, always use the specified tightening torques. When
installing protective parts such as guards, or parts which vibrate violently or rotate at high
speed, be particularly careful to check that they are installed correctly.
22. When aligning two holes, never insert your fingers or hand. Be careful not to get your
fingers caught in a hole.
23. When measuring hydraulic pressure, check that the measuring tool is correctly assembled
before taking any measurements.
24. Take care when removing or installing the tracks of track-type machines. When removing
the track, the track separates suddenly, so never let anyone stand at either end of the
track.
00-3
ENVIRONMENT PROTECTION Environment NOTICE
OPERATION
• Avoid engine idling over long periods. Long periods of idling, more than 10 minutes,
will not only waste fuel, but is also harmful to the engine.
• Avoid operation against the main relief valves of the hydraulic system. Move control
lever to neutral position before the loader attachment stalls due to overload.
• Position trucks in such a way, that loading operation can be carried out in a safe and
economic manner. Avoid swing angles over 90°.
MAINTENANCE
FOREWORD
GENERAL
We describe for you all functions and how to carry out the inspections and
adjustments.
In the table of CONTENT all the functions and components are shown in
their sequence of the description.
If after reading this SERVICE MANUAL you can give us suggestions and
comments for improvements - please do not hesitate to contact us.
00-4
FOREWORD HOISTING INSTRUCTIONS
HOISTING INSTRUCTIONS
HOISTING
• Heavy parts (25 kg or more) must be lifted with a hoist etc.
WIRE ROPES
Wire ropes
(Standard "Z" or "S" twist ropes without galvanizing)
Rope diameter 10,0 11,2 12,5 14,0 16,0 18,0 20,0 22,4 30,0 40,0 50,0 60,0
[mm]
Allowable 1,0 1,4 1,6 2,2 2,8 3,6 4,4 5,6 10,0 18,0 28,0 40,0
load [tons]
2. Sling wire ropes from the middle portion of the hook. Slinging near the edge
of the hook may cause the rope to slip off the hook during hoisting, and a
serious accident can result. Hooks have maximum strength at the middle
portion.
continued
Cont'd:
00-5
FOREWORD HOISTING INSTRUCTIONS
WIRE ROPES
3. Do not sling a heavy load with one rope alone, but sling with two or more
ropes symmetrically wound on to the load.
ã
• Slinging with one rope may cause turning of the load during hoisting,
untwisting of the rope, or slipping of the rope from its original
winding position on the load, which can result in a dangerous
accident.
4. Do not sling a heavy load with ropes forming a wide hanging angle from the
hook. When hoisting a load with two or more ropes, the force subjected to
each rope will increase with the hanging angles. The table below shows the
variation of allowable load (kg) when hoisting is made with two ropes, each of
which is allowed to sling up to 1000 kg vertically, at various hanging angles.
When two ropes sling a load vertically, up to 2000 kg of total weight can be
suspended. This weight becomes 1000 kg when two ropes make a 120°
hanging angle. On the other hand, two ropes are subject to an excessive force
as large as 4000 kg if they sling a 2000 kg load at a lifting angle of 150.
00-6
FOREWORD STANDARD TIGHTENING TORQUE
00-7
FOREWORD CONVERSION TABLE
CONVERSION TABLE
EXAMPLE
00-8
FOREWORD CONVERSION TABLE
00-9
FOREWORD CONVERSION TABLE
00-10
FOREWORD CONVERSION TABLE
00-11
FOREWORD CONVERSION TABLE
00-12
FOREWORD CONVERSION TABLE
°C -0 -1 -2 -3 -4 -5 -6 -7 -8 -9
-50 80,31 79,91 79,51 79,11 78,72 78,32 77,92 77,52 77,13 76,73
-40 84,27 83,88 83,48 83,08 82,69 82,29 81,89 81,50 81,10 80,70
-30 88,22 87,83 87,43 87,04 86,64 86,25 85,85 85,46 85,06 84,67
-20 92,16 91,77 91,37 90,98 90,59 90,19 89,80 89,40 89,01 88,62
-10 96,09 95,69 95,30 94,91 94,52 94,12 93,73 93,34 92,95 92,55
0 100,00 99,61 99,22 98,83 98,44 98,04 97,65 97,26 96,87 96,48
°C 0 1 2 3 4 5 6 7 8 9
0 100,00 100,39 100,78 101,17 101,56 101,95 102,34 102,73 103,12 103,51
10 103,90 104,29 104,68 105,07 105,46 105,85 106,24 106,63 107,02 107,40
20 107,79 108,18 108,57 108,96 109,35 109,73 110,12 110,51 110,90 111,28
30 111,67 112,06 112,45 112,83 113,22 113,61 113,99 114,38 114,77 115,15
40 115,54 115,93 116,31 116,70 117,08 117,47 117,85 118,24 118,62 119,01
50 119,40 119,78 120,16 120,55 120,93 121,32 121,70 122,09 122,47 122,86
60 123,24 123,62 124,01, 124,39 124,77 125,16 125,54 125,92 126,31 126,69
70 127,07 127,45 127,84 128,22 128,60 128,98 129,37 129,75 130,13 130,51
80 130,89 131,27 131,66 132,04 132,42 132,80 133,18 133,56 133,94 134,32
90 134,70 135,08 135,46 135,84 136,22 136,60 136,98 137,36 137,47 138,12
100 138,50 138,88 139,26 139,64 140,02 140,39 140,77 141,15 141,53 141,91
110 142,29 142,66 143,04 143,42 143,80 144,17 144,55 144,93 145,31 145,68
120 146,06 146,44 146,81 147,19 147,57 147,94 148,32 148,70 149,07 149,45
130 149,82 150,20 150,57 150,95 151,33 151,70 152,08 152,45 152,83 153,20
140 153,58 153,95 154,32 154,70 155,07 155,45 155,82 156,19 156,57 156,94
150 157,31 157,69 158,06 158,43 158,81 159,18 159,55 159,93 160,30 16067
00-13
FOREWORD CONVERSION TABLE
TEMPERATURE
Fahrenheit – Centigrade Conversion; a simple way to convert a Fahrenheit
temperature reading into a Centigrade temperature reading or vise versa is to enter
the accompanying table in the center or boldface column of figures.
These figures refer to the temperature in either Fahrenheit or Centigrade degrees.
If it is desired to convert from Fahrenheit to Centigrade degrees, consider the
center column as a table of Fahrenheit temperatures and read the corresponding
Centigrade temperature in the column at the left.
If it is desired to convert from Centigrade to Fahrenheit degrees, consider the
center column as a table of Centigrade values, and read the corresponding
Fahrenheit temperature on the right.
00-14
Main Assembly Groups Section 1.0
Page 1
Section Page
1.0 Main assembly groups
General lay out 2
1.1 Superstructure 3
1.1.1 Machinery house 4
1.1.2 Hydraulic Oil Reservoir 5
1.1.3 Hydraulic Oil Cooler 6
1.1.4 Fuel Tank 7
1.1.5 Counter weight 8
1.1.6 Cab support 9
1.1.7 Operators cab 10
1.1.8 Main pumps and Control blocks 11
1.1.9 Swing gears 12
1.3 Attachment
1.3.1. Backhoe Attachment (BHA) 14
1.3.2. Front Shovel Attachment (FSA) 15
1.1 Superstructure
(11) Engine No 1
(12) Flexible coupling, oil filled and cardan shaft
(13) PTO gear with main hydraulic pumps 1 – 4
(14) Radiator for engine cooling system 1
(15) Engine No 2
(16) Flexible coupling, oil filled and cardan shaft
(17) PTO gear with main hydraulic pumps 5 – 8
(18) Radiator for engine cooling system 2
(19) Batteries
(20) Control blocks with high pressure filters
(21) Swing gears
1.1 Superstructure
1.1 Superstructure
1.1 Superstructure
(9) Additional radiator set (2 identical cooler elements 151.1 and 151.2)
(10) Additional oil cooler fans
(11) Hydraulic motor of additional fan (driven by prime mover 1)
(12) Hydraulic motor of additional fan (driven by prime mover 2)
1.1 Superstructure
1.1 Superstructure
~ 53000 kg
(3) Washers
1.1 Superstructure
(4) Door
(5) Gasket
(6) Door handle (adjustable)
1.1 Superstructure
– KMG Control
– KMG Control
1.1 Superstructure
1.1 Superstructure
1.3 Attachment
1.3 Attachment
Section Page
2.0 Prime drive assembly
General lay out 2
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
2
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 2
General
Each drive unit, consists of the PTO gear and the engine, is bolted to the
power frame.
The connection between engine and PTO gear is the drive shaft and a flexible
coupling.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
3
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 3
(8) Bolts
Bolt size (mm) Grade SW* (mm) Tightening torque (Nm)
M 24 10.9 36 880
* SW = Wrench size
continued
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
4
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 4
Cont'd
Lubrication The flexible bearings are installed to take the vibrations, the
torsion forces and to carry the total weight of the engines.
) • All flexible bearings (1) and all rubber-bounded metal bars (4) should
be replaced during engine overhaul.
• Check distance (A) between torque support and stop bolt (5).
With setting of the flexible engine bearings (1) the distance (A) increases and
must be readjusted. To do this, loosen lock nut (7) and tighten stop bolt (5) until
the correct distance (A) is obtained. Tighten lock nut (7) and recheck distance
(A).
If new flexible engine bearings (1) have been installed, replace also cup springs
(6) and adjust distance (A) to 29 mm.
• Check tie bolts (2) on front and rear carrier units for looseness.
Check to make sure that the self locking retainer nuts (3) are tight and that there is
no gap between nut and rubber-bounded metal bar (4). If necessary retighten
retainer nuts (3) snugly.
Check rubber-bounded metal bars (4) for signs of fatigue and damage.
Replace as necessary.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
5
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 5
General
The drive shaft must transmit the torque from the engine to the PTO.
This requirement makes it necessary that the drive shaft be capable of
transmitting the maximum torque developed by the engine.
It must also be capable of rotating at the maximum speed required for
operation. The length of the drive shaft must be capable of changing while
transmitting torque.
) • When assembling the splined shaft yoke and the slip yoke make sure
the yokes are aligned in the same plane.
Tolerance: 2° 30’ (= 1 tooth of the splined shaft)
The exact position of the yokes is marked by arrows (see illustration)
• Do not remove sheet metal balancing weights from tube of drive shaft.
Balance errors will result in destruction.
• For service intervals and lubrication procedure refer to the
OPERATION AND MAINTENANCE MANUAL of the corresponding
machine.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
6
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 6
Task:
The flexible coupling is the connecting link between the engine and the PTO
Function:
The combination of the high elasticity of its leaf springs with complimentary
viscous damping by oil displacement, ensures that the coupling reduces the
intensity of torsional vibrations effectively.
The widest engine speed range free of vibration periods and dangerous
resonance’s is thus obtained.
The springs (3) together with the inner driving and outer driven member form
chambers A and B which are filled with oil.
If the outer member is displaced in relation to the inner member, the
deflection of the leaf springs displaces oil from one chamber to the next, by
this action the relative movements of the two members of the coupling are
braked and the vibrations are dampened.
The spacers (8) limits the movement of the leaf springs.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
7
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 7
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
8
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 8
continued
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
9
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 9
Cont'd
Function:
From pump (10.2 / 10.4) flows the oil through the filter (68.3 / 68.5) to the fan motor
(64.1 – 64.4) and then back to the tank.
Anti cavitation valves (check valves) are installed at each fan motor, because the fan
motors - driven by inertial force - are running for a short period after the engine has
been switched off.
The hydraulic circuit "Fan drive" is secured by the pilot controlled pressure relief
valve (45.3 / 45.4). This valve works together with the proportional solenoid valve
(Y136-1 / -2). The proportional solenoid valve (Y136-1 / -2) operates depending on
engine coolant temperature.
The ECM (Electronic Control Module) of the engine controls the proportional
solenoid valve (Y136-1 / -2) by sending variable current signals, depending on the
engine coolant temperature.
Which in turn changes the fan speed.
With a low current signal to the proportional solenoid the relief valve is functioning
and the fans are running with the max. set- speed. With a high current signal to the
proportional solenoid the relief valve is not functioning and the fans are running with
a very low speed, caused by the flow resistance only.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
10
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 10
Basic Adjustment
Legend for illustration (Z 21606b):
(1) Dust cap
(2) Lock nut
(3) Set screw
(6) Qmin stop bolt
(6.1) Lock nut
(7) Qmax stop bolt
(7.1) Lock nut
(8) Positioning pin (mover)
(10.2 + 10.4) Axial piston pump (fixed displacement pump, with variable setting)
(45.3 + 45.4) Pressure relief valve - Engine radiator fan drive
(Y136-1 / -2) Proportional solenoid valve - fan speed (infinitely variable)
(L1) Measurement of Qmin stop bolt
(L2) Measurement of Qmax stop bolt
(M7-1 / -2) Pressure check points - Fan drive operating pressure
Continued
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
11
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 11
Cont'd
Basic Adjustment
7. Increase the output flow of pumps (10.2 /10.4), by adjusting the swivel
angle, until the fan speed will be 20 min-1 higher than required:
To do this, loosen both lock nuts (6.1 + 7.1) and turn in bolt (6)
and turn out bolt (7) the same length.
This is necessary to avoid a loose positioning pin (8), resulting in
oscillating of the cylinder barrel.
Tighten the lock nuts (6.1 + 7.1).
8. Loosen lock nut (2) of the relief valve (45.3 / 45.4), and decrease the
pressure with set screw (3) until the correct fan speed is obtained.
9. Tighten lock nut (2) and fix protection cap (3).
10. Activate the function of proportional solenoid valve (Y136-1 / -2), by
connecting the plug connector. (Fan speed controlled in relation to the
engine temperature)
11. Disconnect the pressure gauge from check point (M7-1 / -2).
If the speed can not be raised by increasing the pressure then increase the output
flow of pump (10.2 /10.4).
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
12
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 12
ã
• Detail „S“.
The arrows at detail S indicates the spray direction of the jet borings.
Pay attention when disassembling / assembling.
Description
The pump distribution gear (PTO gear) is of a spur gear design and driven by a
diesel engine.
The PTO gear runs in antifriction bearings and has been provided with a splash
lubrication system. The oil supply of the bearings and tooth contacts takes
place by an injection. The gearwheels are of case-hardened steel.
The hydraulic pumps are directly attached to the gearbox. O-rings included in
the supply enable the unit to be reliably sealed statically.
The gearbox housing is of one-piece design and made of grey cast iron. Gearbox
design allows a direct attachment to the engine via connection flange.
The gearbox has been provided with connections for a separate cooling system
resp. for heating rods. For more information refer to the REPAIR MANUAL
Description for the lubrication see next pages.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
13
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 13
All drive shaft housings are filled with the same gear oil as the pump
distributor gear.
Function:
If the oil level increases the oil drops out of the breather pipe (1).
If this oil is gear oil it indicates a possible leak at the gearbox side.
If the oil is a mixture of gear oil and hydraulic oil it shows a possible
leak at the pump side.
If at an oil level check a loss of oil is found it may be due to worn or
defective radial seal rings.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
14
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 14
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
15
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 15
Cont`d.
2.9 PTO Lubrication and cooling
Legend for illustration (Z 22790):
(1) Pilot operated relief valve (6) Port for pressure check stud
(2) Plug screw (7) Jet bore
(3) Valve piston (8) Valve spring
(4) Port for pressure switch B17-1/-2 (9) Seal rings
(5) "Y"- port (external return to tank) (A) Pressure port
(5a) "X"- port (external return to tank (T) Return from valve
via solenoid valve Y53-1/-2)
(74.1+74.2) Pressure relief valve, 7.5 bar
(114.1+114.2) Pressure reducing valve (fan speed)
(117.1+117.2) Gear Oil cooler unit (incl. hydraulic fan motor)
(M8-1+M8-2) PTO lubrication pressure
(M21-1+M21-2) Pressure check point (fan speed)
(Y53-1+ Y53-2) Solenoid valve (reduced pressure if energized)
(Y6a/b-1 / Y6a/b-2) Solenoid valve Hydr. oil cooler fan speed (max. pressure if
de-energized)
) • If the pressure of 7,5 bar cannot be adj. 100 %, adj. to the lowest
visible pressure.
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
2.0
16
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Drive Section 2.0
Page 16
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
PC8000-6-D_Sec_2-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 1
Section Page
3.0 Hydraulic oil reservoir
General lay out 2
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
2
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 2
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
3
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 3
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
4
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 4
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
5
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 5
(6) Bolt
Quantity Bolt size Grade SW* Tightening
(mm) (mm) torque (Nm)
8 M 20 x 90 10.9 30 510
Task:
The strainer (monitored by differential pressure switch B165) is installed to
prevent the hydraulic oil coolers from getting clogged up in case of
contamination in the main return circuit oil.
Excessive increase of the hydraulic oil temperature can be an indication for a
restricted strainer, i.e. bad cooling performance due to insufficient oil flow
through the coolers.
In case that main components such as cylinders or motors are internal
fragmentary damaged, the strainer should be inspected for metal chips.
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
6
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 6
Task:
The back pressure valve has to fulfill two functions in the hydraulic system:
1. To ensure a sufficient pressure within the return oil circuit, i.e. to supply
oil via the anticavitaton valves to the low pressure side of cylinders,
respectively motors.
2. To force the return oil through the coolers depending on the present
hydraulic oil temperature, controlled by solenoid valve Y101.
- Low temperature ⇒ low volume through the coolers
- High temperature ⇒ high volume through the coolers
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
7
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 7
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
8
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 8
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
3.0
9
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Reservoir Section 3.0
Page 9
A breather filter is installed to clean the air that streams into the tank any time
the oil level decreases while extending attachment cylinders
The filter element condition is monitored by a vacuum type pressure switch
(B24, 80mbar).
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
PC8000-6-D_Sec_3-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 1
Section Page
4.0 Hydraulic oil cooling
4.1 General 2
4.2 Function of the hydraulic oil cooling circuit
4.2.1 Standard hydraulic oil cooling circuit 3
4.2.2 Additional hydraulic oil cooling circuit 4
4.3 Back Pressure Valve
4.3.1 Adjustment of the Back Pressure Valve 5
4.3.2 ½ Qmax adjustment 6+7
4.4 Fan drive of standard cooler
4.4.1 Two stage cooler fan RPM control 8
4.4.2 Pressure relief valves and solenoid valves 9 + 10
4.4.3 Fixed Displacement Pump, with variable setting 11
4.4.4 Adjustment of the cooler fan drive speed 12 + 13 + 14
4.4.5 Function check of fan speed control 14
4.4.6 Switch points cooler fan speed (PLC controlled) 15
4.5 Fan drive of additional cooler
4.5.1 Function of the cooler fan RPM control 16
4.5.2 Adjustment of the cooler fan drive speed 16
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
2
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 2
4.1 General
The hydraulic oil cooling system maintains the hydraulic oil at a normal
operating temperature.
Design:
The hydraulic oil cooler, installed in front of the hydraulic tank is divided in
two parts:
A. The standard cooler assembly (1) with eight cooler elements mounted
in one frame. The air stream needed for the cooling is produced by
hydraulically driven fans. The air flows from inside to outside through
the coolers.
For easy cleaning, the coolers can be opened. ("Swing out cooler")
The bearing group housing is filled with oil to lubricate the bearings.
B. Additional oil cooler assembly (2) with two cooler elements mounted in
one frame on top of the standard cooler assembly. The air stream needed
for the cooling is produced by hydraulically driven fans. The air flows
from inside to outside through the coolers.
For easy cleaning, the coolers can be opened. ("Swing out cooler")
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
3
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 3
Function:
The returning oil from the system flows via the lines into the collector tube.
On the top of it is the Back Pressure Valve (26) installed.
The back pressure valve (26) causes a back pressure which forces most of the
relative hot oil through the lines (H) to the cooler (106.1 – 106.8).
The hydraulic oil passes first the restrictors (107.1 – 107.4) before it gets
cooled in the cooler elements and flows than through and the lines (C) into
the filter chamber of the main oil reservoir (96).
The restrictors are acting like shock absorbers and prevent together with the
pulsation damper (93) cooler cracking at pressure peaks.
Besides the back pressure valve acts as an oil flow control valve as far as the
oil temperature has not reached its steady temperature.
During the warm up period (1/2 Qmax) the back pressure valve (26) is wide
open, because solenoid valve Y101 is energized, which results in less oil flow
through the cooler which causes that the oil gets quicker its optimum
operating temperature.
With increasing oil temperature the oil gets thinner, so that the main pumps
can be shifted to Qmax position and simultaneously solenoid valve Y101 will
be de-energized, so that the valve piston will be more closed by the force of
the spring thus that more oil passes the cooler.
(See sectional drawing on page 5.)
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
4
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 4
Function:
Oil delivery of both fan drive pumps (10.1+10.3) is directed to the additional cooler
elements (151.1+151.2) after leaving the four fan drive motors (103.3+103.4 and
152.1+152.2) and flows back into the filter chamber of the main oil reservoir (96).
This ensures that a constant oil volume circulates through the additional cooler,
independent of the main return oil flow.
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
5
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 5
Checks and settings only at normal operating temperature of the hydraulic oil,
main pumps in maximum flow position and "Idle Time" control eliminated.
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
6
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 6
For efficient hydraulic oil cooling during idle time all pumps are automatically in
½ Qmax position reducing the circulating oil volume so that oil flows only
through the oil coolers. If all pumps would stay in Qmax position during idle time
a high amount of the circulating oil would pass the back pressure valve before
returning in the oil tank this would waste energy and create adverse high oil
temperatures.
Precondition
• The actual PLC software with ½ Qmax idle control must run on the PLC.
• Make sure that the filled in hydraulic oil viscosity is selected at the PLC.
See Operation and Maintenance Manual to select the oil viscosity.
Procedure:
continued
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
7
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 7
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
8
13.
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 8
Function:
From pump (10.1 + 10.3) flows the oil through the filter (68.2 + 68.4) to the fan
motors (23.1 + 23.2) and then back to the tank. (or through additional cooler if
installed)
The check valve (103.3 + 103.4) act as an anti cavitation valve and is installed,
because the fan motor -driven by inertial force- is running for a short period after the
oil flow is interrupted by solenoid valve (Y6a/b-1 / -2), or if the motor has been
switched off.
The hydraulic circuit "Fan drive" is protected by the pilot controlled pressure relief
valves (45.1 + 45.2) and (48.1 + 48.2).
These valves are working together with the solenoid valve (Y6a/b-1 / -2), controlled
by the ECS - system, depending on the hydraulic oil temperature:
• With de-energized solenoids Y6a and Y6b the relief valve (45.1 + 45.2) is
functioning and the fans are running with max. adjusted speed (1250 RPM)
• With solenoid Y6a energized the relief valve (45.1 + 45.2) is not functioning
and the fans are running with a very low speed caused by the flow resistance
only.
• With solenoid Y6b energized the relief valve (48.1 + 48.2) is controlling the
relief valve (45.1 + 45.2) and the fans are running with 1000 RPM only.
(See also description on next page)
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
9
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 9
Function:
Pressure in line A affects the main piston (7). At the same time there is pressure
via the jet bore (6) on the spring-loaded side of the main piston and via jet bore (5)
at the pilot poppet (9) of the relief valve cartridge (1).
If system pressure in line A exceeds the value set at the spring (2), pilot poppet (9)
opens. The signal for this comes from line A via the jet bores (6) and (5).
The oil on the spring-loaded side of the main piston (7) now flows via the jet bore
(5) and poppet (9) into the spring chamber (3).
From here it is fed internally by means of the control line (Y) to tank (port B).
Due to the state of equilibrium at the main piston (7), oil flows from line A to line
B, while the set operating pressure is maintained.
The pressure relief valve (45.1 + 45.2) can be unloaded (Remote controlled) by
means of the port "X" and the combined function of solenoid valve Y6a/b-1 / -2
with pressure relief valve 48.1 + 48.2 .( Function see next page)
continued
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
10
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 10
Function:
With de-energized solenoids (Y6a and Y6b), the spool (3) keeps the "X"
connection of valve (45.1 + 45.2) and port “B“ to port “P“ closed. The pressure relief
valve (45.1 + 45.2) operates normal.
The energized solenoid Y6b, operate the spool (3) and a connection is made
between port “P“ and port “B“ and port "X" of valve (45.1 + 45.2).
The system pressure now opens the main piston (7) of valve (45.1 + 45.2), because
via solenoid Y6b (P to B) the oil from the rear side of piston (7) flows from the "X"-
port to the “P“ connection of valve (48.1 + 48.2). The normal valve function is now
remote controlled by the pressure adjusted at valve (48.1 + 48.2).
The energized solenoid Y6a, operate the spool (3) and a connection is made
between port “P“ and port “A” and port "X" of relief valve (45.1 + 45.2).
The system pressure now opens the main piston (7) of valve (45.1 + 45.2) because
via the "X"-port the oil from the rear side of piston (7) flows to tank. The normal
relief valve function is eliminated.
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
11
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 11
Description.
Pump type A7F0 is a variable displacement pump, designed to operate in open
circuits. It has an internal case drain return. The rotary group is a robust self
aspirating unit. External forces may be applied to the drive shaft.
Changing the swivel angle of the rotary group is achieved by sliding the
control lens along a cylindrical formed track by means of an adjusting screw.
• With an increase in the swivel angel, the pump output increase together
with necessary drive torque.
• With an decrease in the swivel angel, the pump output decreases together
with the necessary drive torque.
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
12
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 12
continued
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
13
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 13
Cont'd
Basic Adjustment – Maximum Speed
4. Connect a pressure gauge to check point (M6-1 and/or M6-2).
5. Start the respective motor.
6. Check the fan speed with a non-contact rev counter
Required fan speed: 1250 min-1
7. Increase the output flow of pump (10.1 and/or 10.2), by adjusting the
swivel angle, until the fan speed will be 20 min-1 higher than required:
To do this, loosen both lock nuts (6.1 + 7.1) and turn in bolt (6)
and turn out bolt (7) the same length.
This is necessary to avoid a loose positioning pin (10), resulting in
oscillating of the cylinder barrel.
Tighten the lock nuts (6.1 + 7.1).
8. Loosen lock nut (b) of the relief valve (45.1 and/or 45.2), and decrease
the pressure with set screw (c) until the correct fan speed is obtained.
9. Tighten lock nut (b) and fix protection cap (a).
continued
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
14
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 14
10. Activate the function of pressure relief valve (48.1 and/or 48.2), by
connecting the plug connector of solenoid valve Y6a/b-1 and/or Y6a/b-2.
11. In order to ensure a proper function of solenoid valve Y6b during the
adjustment, energize the valve by using the manual control “Digital Outputs”
of the ECS-System ( refer to section 5 of the operation manual), or
activate Y6b, by connecting the solenoid plug to permanent 24 V. Use the
24V socket at the PTO *)
12. Loosen lock nut (e) of the relief valve (124), and turn set screw (f) fully
counter clockwise and then clockwise until the correct fan speed is obtained.
Required fan speed: 1000 min-1
13. Tighten lock nut (e) and fix protection cap (d).
14. Note down the pressure as reference value (expected ~ 150 bar)
15. Disconnect the pressure gauge from check point (M6).
16. Connect the plug connector of solenoid valve Y6a.
*) Prepare a test wire with a plug ET-No. 891 039 40, and a plug ET-No. 440
305 99. Connect terminal 1 to positive (+) (center off plug 440 305 99) and
terminal 2 to ground (-).
Switch manually the output signals to Y6a/b and check the fan speed:
Y6a
Y6b
0
0} nmaximum ≈ 1250 min-1
Y6a
Y6b
0
1} nmedium ≈ 1000 min-1
Y6a
Y6b
1
0} nminimum ≈ 0 - 50 min-1
) • For operating instructions of the ECS system refer to section 3.4 of the
operation manual
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
15
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 15
Fan speed
Maximum
Medium
Minimum
Temperature
67°C VG100: 75°C
58°C VG68: 75°C
Switch point: Speed increase 50°C VG46: 69°C
41°C VG32: 59°C
32°C VG22: 48°C
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
4.0
16
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Hydraulic Oil Cooling Section 4.0
Page 16
Since the oil delivery of the fan drive pumps (10.1 + 10.3) is used for the standard
fan motors 23.1 + 23.2 and for the additional fan motors 152.1 + 152.2, the speed
of the additional fans depends on the speed control of the standard fans.
Therefore only the maximum speed of the additional fans can be adjusted with the
cooler standard fans running at maximum speed.
The maximum speed adjustment of the additional fans must be carried out to
ensure the intended cooling performance of the system.
Procedure:
1. Connect a pressure gauge to check point (M21-3 and/or M21-4).
2. Unplug solenoid valve (Y6a/b-1 and/or Y6a/b-2). to ensure max.
speed of the standard fan drive.
3. Start the respective motor.
4. Adjust* at valve (154.1 and/or 154.2.3) a fan speed of approx. 1550 rpm.
5. Re-plug solenoid valve (Y6.1 and/or Y6.2).
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
PC8000-6-D_Sec_4-0_#12046_rev0.doc 02.11.05
Controlling Section 5.0
Page 1
Section Page
5.0 Controlling
General lay out 2
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
2
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 2
General
The controlling includes the pilot pressure system and the pump regulation
system.
The pumps (9.1 / 9.3) forcing the oil through the filters (68.1 / 68.7) to all
involved valves.
The pressure accumulator (85) ensures that under any circumstances enough
pilot pressure oil is available. The accumulator (85) is also functioning as a
hydraulic battery for a certain time when the engine was shut down or to
pressure relieve the system for repair works.
When the operator is using his controls an electrical signal causes energizing
of the selected solenoid valve of the remote control valves(102).
By the function of the remote control valves pilot pressure oil is send to the
relevant control block spools which in turn allows operating hydraulic oil to
the users.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
3
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 3
Solenoid valves
(Y5) Swing parking brake operating pressure
(Y16) Travel parking brake operating pressure
(Y17) „Idle time“ control, (Pump control system)
(Y17a) ½ Q-max (reduced oil flow at too cold oil)
(Y61-1) „X1“ pressure, pumps 1 – 4 (Engine 1)
(Y61-2) „X1“ pressure, pumps 5 – 8 (Engine 2)
(Y100) Flow reduction Pump 1, while swinging with maximum speed
(Y120) Hydraulic swing brake, maximum operating pressure
(Y123a) Hydraulic access ladder “raise”
(Y123b) Hydraulic access ladder “lower”
(Y124a) Refilling arm “raise”
(Y124b) Refilling arm “lower”
(Y124c) Refilling arm stop (fix) – arm park valve
(Y125) Hydraulic access ladder “fast” movement
(Y127) Proportional pressure to hydraulic swing brake
Filter:
(68.1) Pressure filter of pilot pressure pump 9.1 (Engine 1)
(68.7) Pressure filter of pilot pressure pump 9.3 (Engine 2)
Pressure switches:
(B16) Swing parking brake operating pressure
(B22-1) Pilot pressure pump 9.1 (Engine 1) - Filter element monitoring
(B22-2) Pilot pressure pump 9.3 (Engine 2) - Filter element monitoring
(B48) Travel parking brake operating pressure
(B85-1) Pressure transducer – X1 pressure (Engine 1)
(B85-2) Pressure transducer – X1 pressure (Engine 2)
(B86) Pressure transducer – X2 pressure
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
4
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 4
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
5
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 5
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
6
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 6
The pressure reducing valve (252.1) maintains the adjusted pressure of 45 bar,
called „X2“-pressure.
X2 – pressure: Pilot pressure system
Pump regulation system
Travel- and Swing parking brakes (spring loaded multi -disk
brakes)
The pressure accumulator (85) holds an amount of oil under pressure to provide
sufficient pilot pressure during normal operation and to ensure a limited number
of lowering operations with the main drive Engine at standstill.
The check valve (256.6) prevents return flow of the pilot pressure oil.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
7
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 7
Function:
The pilot pressure oil flows via line (PX2) to port (P) of each remote control
block and is present via a gallery at all proportional and directional solenoid
valves.
These solenoid valves are energized by the function of the Electro
proportional controls (Joy sticks or pedals) and direct the pilot pressure oil to
the respective spools of the main control blocks with a variable pilot pressure
proportional to the deflection of the controls.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
8
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 8
) • Since the “X2” and the “X4” pressure are influencing each other it is
always necessary to adjust both valves 252.1 + 252.2 alternately.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
9
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 9
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
10
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 10
Function:
The electric-hydraulic control system is used to control the direction and
volume of oil flow to the operating cylinders and engines via the control
valve blocks.
Hydraulically:
The oil volume of pump (1) flows through filter (2) into the pilot pressure
system. The pressure is limited by the pressure relief valve (3).
With the pressurized oil stored in accumulator (5), a limited number of spool
movements can be carried out with the main drive engine at standstill.
When a lever (or pedal) is actuated, proportional solenoid valve (8) and one
of the directional solenoid valves (either 6 or 7) are energized, and allows the
pilot pressure oil to flow to the spools of the control blocks.
Electrical
Whenever a lever or a pedal is moved out of its neutral position, an amplifier
will created a current between 0 and 1000 mA. (For detailed information refer
to page 11 in this section)
Depending on the lever direction, simultaneously one of the directional
solenoid valves (either 6 or 7) is energized.
The proportional solenoid valve alters the pilot pressure, proportional to the
lever deflection, this results a spool movement between neutral and full
stroke position.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
11
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 11
(Exemplary illustration of the function of two axis with one Amplifier only)
Legend for illustration (Z 21638c)
(1) Control lever (joystick)
(2) Capacitor-Module
(3) Ramp time module
(4) Proportional-Amplifier-Module
(5) Relay (Supply Voltage)
(6) Proportional solenoid valve-(Pressure-Reducing Valve)
(7) Directional solenoid valve
(8) Control block spool
General Function
Control lever (1) is supplied with 24 VDC battery voltage for the switch contacts
and with 24 VDC capacitor supported to create the signal voltage.
When moving lever (1) out of its neutral position, 24 VDC battery voltage arrives
at relay (5) and energizes the Proportional Amplifier (4) with capacitor
supported 24 VDC via terminal 1.
Depending on the function of the control lever, 1 to 4 Amplifiers can be involved
for the „Y-axis“ (forward/ backwards direction) and 1 to 4 Amplifiers for the „X-
axis“ (left/right direction.)
The polarity of the Output Signal from joystick (1), either positive or negative,
between 0 and 10 VDC indicates the direction of the lever movement and is
proportional to the lever deflection. This is the Input Signal to the ramp time
module (3) at terminal 5 which will arrive after the adjusted ramp time delay via
terminal 7 to the proportional amplifier (4) at terminal 5.
This Input Signal (between 0 and 10 VDC) is amplified to an Output Signal
between 0 to 1000 mA and is simultaneously send via terminal 7 (negative) or
terminal 8 (positive) to the Proportional Solenoid valve (6) and to the
Directional solenoid valve (7) via terminal 3 (negative) or terminal 9 (positive)
to the “a” or “b”-side.
The proportional Solenoid valve (6) alters the pilot pressure (“X2”) of 45 bar to a
value proportional to the Current Signal.
This pressure controls the movement of the control block spool (8) between
neutral and full stroke position.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
12
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 12
In order to be able to monitor the direction of the lever movement and the
neutral position, the electronics (8) sends a 24V signal as soon as the lever
gets moved out of its neutral position.
For one axis are used two inductive linear transmitter (3). The motion of the
coil core (9) connected to the push pin (6) causes a variation of the induction
in the coils (10). The electronics convert this inductive signal into a
proportional output signal of –10...0...+10 V for the amplifiers.
The electronic part of the lever is equipped with a internal fault detector. In
case of a internal electronic fault the electronic send a 24V signal to the test
output. The test input is used for a lever system check before engine start.
The inductive system is designed as a redundant system with two separate
coils.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
13
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 13
Application for:
(A) Swing foot brake
(B) Clam Opening/closing
(C) Travelling
In order to be able to electrically monitor the pedal (2) action a neutral position
switch is fitted.
This switch closes when the pedal is moved out of the rest position.
When using the double unit (B) (combined operation) only the signal output from
one unit is used for the Clam Operation.
Due to the cross lined connection via the connection cable (4) the signal is once
positive and once negative (inverted), depending on the Pedal used.
In order to be able to monitor the direction of the pedal movement and the neutral
position of travel unit (C), two switches (5 and 6) are fitted; which are actuated by
the actuator (4) as soon as the lever gets moved out of its neutral position.
For the Output Signal generation are used two coils (3.1), in series connected. The
push pin motion causes a variation of the induction and this in turn causes a signal
variation at the AC voltage bridge. The AC voltage gets rectified and becomes the
DC-Signal Voltage for the amplifiers.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
14
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 14
The amplifier module contains the necessary electronics for the control of
two proportional solenoids. Depending on the input polarity, either solenoid
A or solenoid B is operated.
The solenoid current (solenoid A - solenoid B) is measured and compared
with the external input value. Differences between feed-back and input
values, for example caused by changes in solenoid temperature or supply
voltage, are compensated.
The module also generates a direction-dependent voltage signal (solenoid A -
solenoid B) as soon as the solenoid current reaches the lowest set value.
The lowest and highest values are set externally via the potentiometer R1 + R2.
The brightness of the LED's changes with the current.
This function should not be used for setting.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
15
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 15
The amplifier module contains the necessary electronics for the control of
two proportional solenoids and two directional solenoids. The amplifier
outputs for proportional solenoids Ax and Bx and the switched outputs As
and Bs are activated by connecting a minimum of approx. 10% signal voltage
at the amplifier input.
A positive signal voltage controls outputs A, a negative signal voltage
controls output B.
A signal voltage of approx. 10% with respect to +/- 10 V input voltage at the
amplifier, produces a stepped output voltage. The height of this 10% jump
may be set separately for proportional outputs Ax and Bx via external
potentiometer. As the signal voltage rises the solenoid current for the
proportional outputs increases linearly.
A further step in output current occurs at approx. 90% signal voltage.
The maximum current or the 90% jump may be set separately for outputs Ax
and Bx via external potentiometers and hence the gradient of the output curve
may be influenced.
LED`s indicate the current output to each proportional and switched output,
whereby the brightness is approx. proportional to the solenoid current in Ax
and Bx. This function should not be used for setting.
A Ramp Time function is included in the amplifier which may be externally
changed by a set potentiometer. The setting range for the ramp time is
approx. from 80ms to 1s. The time setting applies to both up and down ramps
and to both proportional solenoids.
A fault is indicated by the LED „Fault“.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
16
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 16
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
17
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 17
Introduction:
The illustration shows simplified the route of the signal voltage from
Potentiometer Control (1) to Solenoid-Valve (5):
A. With ramp time module,
i.e. Boom,- Stick,- Travel,- and Swing Function.
B. Without ramp time module,
i.e. Bucket and Clam Function.
The ramp time modules (3) and the amplifiers (4) are adjustable.
Adjustments are required:
Ramp time modules Amplifiers
• When commissioning the machine • When replacing a solenoid valve
• When replacing a module • When replacing an amplifier
For Checking and Setting the Signal Current at the Proportional-Amplifier (4),
both separating terminal (2) before and behind the Amplifier (4) must be opened.
For the setting procedure the signal voltage from the potentiometer control (1) can
be simulated with the potentiometer of Service-Module (6),which is installed on
the X2-panel.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
18
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 18
Procedure applicable for all amplifiers except the one for the swing
brake:
(Do not start the engine, turn only the key switch in ON – position.)
1. Open* the respective separating terminal (T1) between the lever unit and
the amplifier module to be set.
2. Open* the respective separating terminal (T2) between the amplifier module
to be set and the proportional solenoid valve.
3. Disconnect the wire from terminal five.
4. Connect the positive output of the service module with terminal five of the
amplifier module, using test lead (2).
5. Attach a multimeter for voltage reading to the service module, using test
lead (3).
6. Attach a multimeter (in series) for Amp reading to the terminal between
amplifier module and solenoid valve, using test leads (3).
7. Move the lever of the Potentiometer Control into its final position; or
override manual the relay which allows 24 V operating voltage to the
amplifier module; thus the amplifier gets 24 V operating voltage. The
power LED and simultaneously LED A(+) or B(-) lights up, depending on
the polarity.
8. Turn the potentiometer (P) of the Service-Module until the multimeter
shows 1 VDC (it may be either positive or negative); the multimeter for the
current reading will show a value which should correspond to the value
giving in the circuit diagram e.g. 330 mA. (The first step (10 %) value)
If necessary correct the value with potentiometer (R1).
9. Turn the potentiometer (P) of the Service-Module further until the
multimeter shows 9 VDC; the multimeter for the current reading will show
a value which should correspond to the value giving in the circuit diagram
e.g. 660 mA. (The second step (90 %) value).
If necessary correct the value with potentiometer (R2).
10. Repeat settings of item 8 and 9 until both mA values are stabilized, because
R1 and R2 influence each other.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
19
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 19
Cont'd:
11. If the setting with either positive or negative potential was successful, turn
the potentiometer (P) of the service module into the opposite direction and
check the settings with the other polarity i.e. if the first setting was done
with positive potential then turn the pot into negative direction; otherwise
vice versa.
12. Repeat the setting as described under item 7 to 10.
13. Remove multimeter, test wire, close* the terminals and reconnect the wire
to terminal 5 of the amplifier module.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
20
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 20
The amplifiers for the crawler foot pedals are adjustable in the same way as
the amplifiers for the joy sticks.(refer to page 17 and 18 in this section)
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
21
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 21
Cont'd:
) • It is important that the pilot pressure for the pressure increasing valve
is 30 +/- 1 bar.
For more information refer to section 8.2 „Swing Circuit“
10. Repeat settings of item 8 and 9 until both mA values are stabilized, because
R1 and R2 influence each other.
11. Remove multimeter, test wire, close* the terminals and reconnect the wire
to terminal 5 of the amplifier module.
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
22
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 22
Basic Adjustment:
1. Connect 0VDC with a test lead from the red positive terminal of the service module
(6) to terminal 5 of the Ramp Time Module (3) and adjust with "Pot Z" a value of 0
VDC measured at terminal 7. Disconnect the test lead after the setting is done.
2. Connect +10VDC with a test lead from the red positive terminal of the service
module (6) to terminal 5 of the Ramp Time Module (3) and adjust with "Pot G" a
value of 10 VDC measured at terminal 7. Check the negative voltage as well(- 10
VDC). Disconnect the test lead after the setting is done.
) • Repeat settings of item 1 and 2 until both values are stabilized, because
"Pot Z" and "Pot G" influence each other.
• The factory setting of potentiometer "w1" to "w4" for the command
value call-ups must not be adjusted.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
23
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 23
Cont'd:
5. If the above mentioned values are not suitable for the local working conditions, for
example due to, different Attachments or different operation feeling of the operator,
the ramp time can be changed according to the NOTE on illustration
Z 21645, to ensure smooth and efficient working cycles.
continued
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
5.0
24
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Controlling Section 5.0
Page 24
Cont'd:
E48 Stick
24 Volt at Joy stick Signal Pot Value to be measured at socket "t"
Terminal 9 Neutral ⇒ Stick out 0V to +10V t1 0,10 Volt = 1000ms
Terminal 10 Stick out ⇒ Neutral +10V to 0V t2 5,00 Volt = 20ms
Terminal 11 Neutral ⇒ Stick in 0V to -10V t3 0,10 Volt = 1000ms
Terminal 12 Stick in ⇒ Neutral -10V to 0V t4 5,00 Volt = 20ms
E49 Boom
24 Volt at Joy stick Signal Pot Value to be measured at socket "t"
Terminal 9 Neutral ⇒ Lower 0V to +10V t1 0,10 Volt = 1000ms
Terminal 10 Lower ⇒ Neutral +10V to 0V t2 5,00 Volt = 20ms
Terminal 11 Neutral ⇒ Lift 0V to -10V t3 0,10 Volt = 1000ms
Terminal 12 Lift ⇒ Neutral -10V to 0V t4 5,00 Volt = 20ms
E50 Swing
24 Volt at Joy stick Signal Pot Value to be measured at socket "t"
Terminal 9 Neutral ⇒ Swing R 0V to +10V t1 0,20 Volt = 500ms
Terminal 10 Swing R ⇒ Neutral +10V to 0V t2 0,10 Volt = 1000ms
Terminal 11 Neutral ⇒ Swing L 0V to -10V t3 0,20 Volt = 500ms
Terminal 12 Swing L ⇒ Neutral -10V to 0V t4 0,10 Volt = 1000ms
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
PC8000-6-D_Sec_5-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 1
Section Page
6.0 Components
6.1 Hydraulic
6.1.1 Main Control Blocks and High Pressure Filter 2
6.1.2 Distributor Manifold – Location of Restrictor blocks 3
6.1.3 Restrictor Block with Pressure Relief Valve (Type 131) 4
6.1.4 Restrictor Block with Pressure Relief Valve (Type 132) 5
6.1.5 Anti Cavitation Valve Block (Type 109) 6
6.1.6 Anti Cavitation Valve Block (Type 142 - 145) 7
6.1.7 Remote Control Valves 8
6.1.8 Directional Solenoid Valves (Three positions / 4-ways) 9
6.1.9 Proportional Solenoid Valves 10
6.1.10 High Pressure Filter 11
6.1.11 Control Blocks and Valves 12 - 16
6.1.12 Travel Brake Valve 17
6.1.13 Pressure Reducing Valve 18
6.1.14 Directional Solenoid Valves (Two positions / 4-ways) 19
6.1.15 Pressure Increasing Valve 20
6.1.16 Hydraulic Cylinder 21
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
2
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 2
Circuit No. I
(127/I) Main Control block (Travel L.H. / Stick / Bucket / Boom)
(18.2) High pressure filters for main pumps 2 + 6 (double unit), with
differential pressure switches B6-1 and B6-2.
(32.1+32.2) Anti Cavitation Valve (ACV) – Travel motors
(32.4) ACV – Bucket cylinder rod side
(32.5) ACV – Bucket cylinder piston side
(33.1) Service-line Relief Valve (SRV) – Stick cylinder rod side
Circuit No. II
(128/II) Main Control block (Swing / Boom / Stick / Bucket)
(18.1) High pressure filters for main pumps 4 + 8 (double unit), with
differential pressure switches B5-1 and B5-2.
(32.7) ACV – Bucket cylinder rod side
(32.8) ACV – Bucket cylinder piston side
Circuit No. IV
(130/IV) Main Control block (Clam / Bucket / Stick / Boom)
(18.4) High pressure filters for main pumps 1 + 5 (double unit), with
differential pressure switches B8-1 and B8-2.
(32.16) ACV – Bucket cylinder rod side
(32.17) ACV – Bucket cylinder piston side
(33.7) SRV – Boom cylinder rod side
(33.9) SRV – Stick cylinder piston side
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
3
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 3
6.1.2 Distributor Manifold - Location of restrictor blocks and anti cavitation valves
Front Shovel Attachment
Legend for illustration (Z 22728):
(SB) Synchronization (Equalization) block
(SL) Synchronization (Equalization) lines
Pressure check point
(73) Distributor manifold
(142) Section A – B, Anti Cavitation Valve (ACV) Block , Boom
cylinder
(132.1+.2) Section B Restrictor blocks, Boom cylinder piston side
with SRVs and check points M16.1 + M16.2
(131.1) Section C Restrictor block, Bucket cylinder piston side
with SRV and pressure check point M17.1
(131.4) Section E Restrictor block, Bucket cylinder piston side
with SRV and pressure check point M17.2
(92) Section F Valve block SRVs, Clam cylinder piston side
with check points M20.1 + M20.2 + M20.3
(109.2) Section G ACV Block, Stick cylinder rod side
(131.5+.6) Section H Restrictor blocks, Stick cylinder piston side
with SRVs and check points M19.1 + M19.2
(143) Section H – J, Anti Cavitation Valve (ACV) Block , Stick cylinder
(131.7+.8) Section K Restrictor blocks, Stick cylinder piston side
with SRVs and check points M19.3 + M19.4
(131.9) Section L Restrictor block, Clam cylinder rod side
with SRV and pressure check point M19.5
(144) Section M – N, Anti Cavitation Valve (ACV) Block, Bucket cylinder
(131.11+.12) Section N Restrictor blocks, Bucket cylinder piston side
with SRVs and check points M17.3 + M17.4
(132.3+.4) Section P Restrictor blocks, Boom cylinder piston side
with SRVs and check points M16.3 + M16.4
(145) Section P – Q, Anti Cavitation Valve (ACV) Block, Boom cylinder
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
4
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 4
Function:
Setting of the maximum permissible cylinder speed (flow B to A) is carried
out by spindle (1). Depending on the spindle setting, the radial holes (9.1) in
the valve poppet (9) will be partially opened to achieve the required throttling
of the oil flow.
The extra holes (fixed throttle 9.2) prevents the valve from becoming
completely closed.
For the lifting operation (flow A to B), the valve poppet (9), which is guided
by the spindle (1), is pressed against spring (7) so that the valve will be
completely open.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
5
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 5
Function:
Setting of the maximum permissible cylinder speed (flow B to A) is carried
out by spindle (1). Depending on the spindle setting, the radial holes (9.1) in
the valve poppet (9) will be partially opened to achieve the required throttling
of the oil flow.
The extra holes (fixed throttle 9.2) prevents the valve from becoming
completely closed.
For the lifting operation (flow A to B), the valve poppet (9), which is guided
by the spindle (1), is pressed against spring (7) so that the valve will be
completely open.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
6
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 6
Function:
The circuit pressure in the line A and B hold the valve cone (2) closed. The
pressure of the supply line S forces onto the valve cone.
The valve cone opens, whenever the pressure at the A and B side is lower
than the back pressure at return oil port S, to allow necessary oil supply into
the circuit.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
7
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 7
Function:
The circuit pressure in the line A and B hold the valve cone (2) closed. The
pressure of the supply line S forces onto the valve cone.
The valve cone opens, whenever the pressure at the A and B side is lower
than the back pressure at return oil port S, to allow necessary oil supply into
the circuit.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
8
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 8
Function:
The electric-hydraulic control system is used to control the direction and
volume of oil flow to the operating cylinders and motors via the main control
valve blocks.
When a lever (or pedal) is actuated, a proportional solenoid valve (13) and
one of the directional solenoid valves (12 either a or b) are energized, and
allows the pilot pressure oil to flow to the spools of the main control blocks.
The proportional solenoid valve alters the pilot pressure, proportional to the
lever deflection, this results a spool movement between neutral and full
stroke position.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
9
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 9
Function:
In un-operated condition the control spool (3) is held in the neutral or
starting position by the reset springs (4). Operation of the control spool is by
means of oil immersed solenoids (2).
The force of the solenoid (2) acts via the plunger (5) on the control spool (3)
and pushes its from its resting position into the required end position. This
results in the required free flow from P to A and B to T or from P to B and
A to T.
When the solenoid (2) is de-energised, the control spool (3) is returned to its
original position by the reset springs (4).
Where necessary restriction orifices are installed into the valve ports, to
reduce the oil flow.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
10
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 10
Function:
In unoperated condition the control spool (2) is held in the neutral or starting
position by reset springs.
The control spool (2) is directly operated by the proportional solenoid (1).
If the solenoid is energized, it produces a force to operate the control spool (2) via
the pressure measuring spool (4) and moves the spool to the left. Oil flows from P
to A. As pressure in A increases, it passes via the radial borings in the control
spool (2) to the inner end of the pressure measuring spool (2).
The force generated by the pressure now works against the solenoid force and
pushes the control spool (2) to the right (closing direction) until a balance is
achieved between the two forces. In order to achieve this, the pressure measuring
spool (2) moves to the left until it is supported by the pin (5).
When the force balance is achieved, the connection between P and A is
interrupted and the pressure in line A is held constant.
Any reduction in the solenoid force leads to the pressure force exceeding the
solenoid force on the control spool (2). The control spool is then moved to the
right causing a connection from A to T allowing the pressure to fall until a
balance is re-established at a lower level.
At rest, when the solenoid is de-energized, ports A and B are open to tank, whilst
port P is blocked from both ports A and B.
- Remove plug 8
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
11
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 11
Function:
High-pressure in-line filters prevent contamination from entering the
hydraulic circuits. The spin-on filters are installed between the main
hydraulic pumps and multi-valve control blocks. All hydraulic components,
behind the pumps, are effectively protected from damage and undue wear.
Each filter is equipped with a differential pressure switch to monitor the filter
flow restriction. If the pressure reaches an unsafe difference of 8.5 bar, a
message appears on the display in the cab.
Example:
Fault No. 674: $h: High pressure filter #5 or pump #5
(677) restricted. Stop Motor 2
Help: Differential pressure switch B5-2 not closed.
- Clean or replace filter element.
- Check pump
or
Fault No. 644: $h: Start of motor 2 blocked due to
(647) contamination of pump #5
Help: Differential pressure switch B5-2 not closed.
- Check cables to differential pressure switch B5-2.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
12
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 12
a2 / a3
Spools without a symbol (standard) are connecting the rod side of the cylinders
with the pump supply line and the piston side with the tank.
Spools with #-symbol are connecting the piston side of the cylinders with the tank
only. (lowering with free pump circulation, i.e. the pressure channel is connected
to the center channel, so that pump flow is available for other functions.)
Spools with $-symbol (floating) are connecting the piston side of the cylinders
with the rod side and also with the tank.
The Load Holding Valves are installed inside of the spool, for each port to
the cylinder or motor one valve. The hydraulic diagram shows only one.
The MRV is a pilot operated pressure relief valve.
continued
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
13
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 13
Example 2: Spool #2 moves up when pilot pressure is build up in the control pipe
line a2. (Imagine the upper symbol box moves to the center position.)
Now pump oil flows through check valve (2) to the user port A2 (stick cylinder
rod side) because the free flow circulation to the hydraulic reservoir is closed. The
main relief valve (1) limits the maximum operation pressure in this circuit. Via
port B2 the return oil from the stick cylinder piston side is flowing back to the
hydraulic oil reservoir.
SRV (4) is installed to limit maximum possible pressure peaks in the service line..
Shortly high pressure closes check valve (2) which secures the hydraulic pump
from pressure peaks.
The check valves (2) have also the function of load holding valves because during
the fine controlling period all lines are connected together (negative over-
lapping). The load pressure is for a moment higher than the pump pressure.
continued
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
14
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 14
Function:
Reset springs (2) moves the spool (1) in neutral position.
Upper picture:
In neutral position of spool (1) the pump oil is flowing back via port PU to the
tank.
Lower picture:
Example. The spool is moved by pilot pressure on the left spool side to right
position: Port PU is closed and the connection through the holding valve (3) to
the user (port A) is open. Also the connection from the other user side (port B
return) is connected to the port T (return line to tank).
continued
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
15
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 15
MRVs and SRVs are pilot operated relief valves. The MRV limits the max.
Pump supply line pressure. The SRV limits the max. possible pressure peak in
the service-line.
The valves have an „opening characteristic“. That means, that in case of
contamination after the response procedure no further pressure increasing is
possible and damages are avoided.
Function:
The circuit pressure P forces with the force F1 on the piston surface A of the
main valve cone (15). Because there is via the jet bore (16) the same pressure on
the back side of the main cone, this results together with the spring (14) force in
a force F2 that keeps the main cone closed. Via the jet bore (13) the circuit
pressure is in front of the poppet (12). Exceeds the circuit pressure the setting
value of the spring (11), the poppet opens against the force of the spring (11).
This causes that the force F2 decreases and there is no more balance condition
between F1 and F2. Valve cone (15) is moved upwards by the greater force F1.
That means there is now a direct connection from port P to T (tank).
ACVs serve for compensation possible lack of feed when the SRV at the
opposite port is actuated (see circuit diagram) and for avoiding cavitation
damages. In addition, to supply a user in case it is continuously moved by
acceleration forces at zero position of the control spool.
Function:
The circuit pressure inside the spring chamber closes the valve cone (7).
The back pressure of the return line acts on the surface of the valve cone (7).
Whenever the pressure in the service-line is lower than the springs force the
valve cone opens by the force of the back pressure and hydraulic oil is additional
supplied.
continued
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
16
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 16
Function:
In neutral position (upper picture) of the spool (1) both valve cones (3) are
closed by the springs (2).
In switched position (lower picture) forces the circuit pressure onto the front
area of the valve piston (3).
This force moves the piston against spring (2) and allows the oil to flow from
the pump supply port (P) to the user port (A) and from port B to the return oil
passage (T).
If due to an external force the pressure directed to the pump overcomes the
pressure in the pump line; this pressure (force) closes the valve
(direction P to A).
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
17
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 17
Illustration Z 21695
Task:
Travel brake valves control the oil flow from the hydraulic motor to the tank
depending on operating pressure. This braking action prevents the motors from
overspeeding.
Function:
Spring force keeps the spool in the lowest flow position. with increasing
operating pressure the opening for the return oil flow becomes larger.
On its way to the hydraulic motor the oil flows from A to A1 respectively from
B to B1 depending on the selected travel motion.
Example:
Operating pressure at port A moves spool (1) against the force of the spring (2)
and opens the way for the return oil (B1 to B).
Check valve (3) prevents a direct oil flow from B1 to B.
If the operating pressure decreases to such an extend that the spring force
overcomes the pressure, the flow to the tank becomes restricted, resulting in
braking of the machine.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
18
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 18
Function:
Pressure reducing valves type DR & DP are direct operated valves of 3 way
design, e.g. with a pressure relief function on the reduced pressure side.
At rest, the valve is normally open, and fluid can flow unhindered from port P
to A. Pressure in port A is also present on the end of the spool (2), via control
line (6), opposing the compression spring (3). When the pressure in port A
reaches the pressure level set at spring (3), spool (2) moves to the control
position and holds the pressure in port A constant.
Fluid to control the valve is taken from port A via the boring (6).
If the pressure in port A rises still further due to external forces, the spool (2)
is moved still further towards the compression spring (3).
This causes a flow path to be opened over control land (8) in the control spool (2)
to tank. Sufficient fluid then flows to tank to prevent any further rise in pressure.
An optional non return valve (5) is available to allow free flow from A to P.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
19
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 19
Function:
When there is no flow through the valve, control spool (3) is held in neutral
or output position by means of the return springs (4). The control spool (3) is
operated by means of oil immersed solenoid (2).
The force of the solenoid (2) effects control spool (3) by means of the plunger
(5) and pushes it from its resting position to the required end position.
This results in free flow from or P to B and A to T.
When solenoid (2) is de-energized, control spool (3) is moved back to its
resting position by means of return springs (4).
An optional hand emergency (6) allows movement of the control spool (3)
without energizing the solenoid.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
20
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 20
Function:
The valve poppet (2) is connected via the jet bores (11) and (12) with the P
port.
If static pressure increase above the set pressure value, the valve poppet (2)
opens and allows oil to flow freely to tank (T1). This oil generates a pressure
drop in the spring chamber of the main spool, the closing force of the spring
(6) is cancelled, and the main piston (5) opens to allow the pump flow to flow
to tank (T2).
Damped opening and closing is obtained by the throttled volumetric change.
By applying external pressure of Pst max = 45 bar to the main spool (9) via
port X, the pre-tensioning of the pressure spring (3) is increased by the amount
of the piston stroke "S" and system pressure is increased correspondingly.
The possible pressure increase p is 440 bar max. or 440 bar minus the basic
setting.
The setting is fixed by means of the setting screw (7) and lock nut (13); 1 turn
of the screw = 150 bar.
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
6.0
21
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Components Section 6.0
Page 21
General A
(1) Piston rod Flange bushing: Boom-, Stick-, Bucket-Cylinder
(2) Rod eye bushing A1 Scraper ring
(3) Piston A2 Support bushing
(4) Cylinder tube A3 Hard-plastic back-up ring
(5) Piston fitting key A4 Back-up ring
(6) Piston nut A5 Chevrons
(7) Piston nut lock (threaded pin) A6 Header ring
(8) Foot end eye bushing A7 Scraper retainer ring
A8 Cover
A9 Steel shims (splitted)
B
Flange bushing: Clam cylinder C = Piston rings
B1 Scraper ring C1 Piston seal ring
B2 „BD“ seal (Dynamic Seal) C2 Piston guide rings, hard
C3 Piston guide, soft
C4 O-ring with back-up rings
Explanation of the cylinder
markings
430/290X3150 Piston diameter / Rod diameter X Stroke
430630 40 Cylinder drawing number (identical with part
No.).
11 / 97 Assembling Month and year (final figure).
261 Internal counting number.
DB 55. Assembling crew personal code
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
PC8000-6-D_Sec_6-0_#12046_rev0.doc 03.11.05
Main Hydraulic Pumps Section 7.0
and Page 1
Pump Regulation System
Section Page
7.0 Main hydraulic pumps and pump regulation system
General 2–5
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
2
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 2
Pump Regulation System
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
3
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 3
Pump Regulation System
General
Controlled output flow of the main pumps is necessary:
• To utilize the available motor power most efficiently in every operating
mode.
• To limit the power consumption of the hydraulic pumps depending on the
load of the motor. (Electronic pump regulation with micro-controller MC7)
• For additional functions, such as temperature-dependent flow reduction.
Function:
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
4
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 4
Pump Regulation System
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
5
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 5
Pump Regulation System
Function:
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
6
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 6
Pump Regulation System
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
7
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 7
Pump Regulation System
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
8
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 8
Pump Regulation System
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
9
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 9
Pump Regulation System
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
10
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 10
Pump Regulation System
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
11
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Assembly Groups Section 7.0
Page 11
Pump support pressure X4 passes valve #7 position "b" and flows via power
control valve #9 position "a" to the large area side of positioning piston #13
Because the large area side of positioning piston #13 is approximately three
times larger as the small area side, the pump support pressure X4 of 60 bar
present on both sides, resulting in stronger force at the large area side, keeps
the pump in Q-min position.
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
12
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 12
Pump Regulation System
The large area side of positioning piston #13 is connected, via power control
valve (9) position "a" and pressure balance valve (7) position "a", to the
return oil line.
The pump moves into Q-max position, because the pump pressure acts only
at the small area side of positioning piston #13.
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
13
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 13
Pump Regulation System
The large area side of positioning piston #13 is connected, via power control
valve (9) position "a" and pressure balance valve (7), to the return oil line.
The pump moves into ½ Q-max position, because the return oil flow through
pressure balance valve (7) is restricted (due to its intermediate position),
resulting in a pressure at the large area side of the positioning piston (13).
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
14
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 14
Pump Regulation System
The operating pressure (with the value for start of de-stroking) at the slipper
pad of piston #14 moves the power control valve (9) into position "b" (against
the spring force supported by the X1-pressure).
This in turn connects the operating pressure to the large area side of
positioning piston #13.
Because the large area side of positioning piston #13 is approximately three
times larger as the small area side, the operating pressure present on both sides,
resulting in stronger force at the large area side, moving the pump in Q-min
direction.
The pump de-strokes until the forces at positioning piston #13 are
balanced
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
15
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 15
Pump Regulation System
Pressure cut-off valve: (DR control valve, Pump moves into Q-min. position)
The operating pressure moves the pressure cut-off valve #11 (at set pressure)
into position "b" and flows to the large area side of positioning piston #13.
Because the large area side of positioning piston #13 is approximately three
times larger as the small area side, the operating pressure present on both
sides, resulting in stronger force at the large area side, moving the pump in Q-
min position.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
16
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 16
Pump Regulation System
Location of Adjustments
Legend for , illustration (Z21557)
(1) Remote control valve
(2) Q-min. stop bolt
(3) Pressure balance valve
(4) Start of destroking
(5) Power curve correction
(6) Pressure cut-off valve
(7) Q-max. stop bolt
(8) Angle indicator
The average length of the measurement "L" is: set crews (bolts )
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
17
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 17
Pump Regulation System
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
18
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 18
Pump Regulation System
The reason of this check is to make sure, the pump starts destroking at an
operating pressure of 180 bar with a pump regulation pressure X1 of 13 bar.
1. Connect a 400 bar pressure gauge to the pressure check point at the
respective high pressure filter for the pumps being checked.
2. Connect a 25 bar pressure gauge to pressure check point M5-1
respectively M5-2 at the control and filter panel (X1-pressure).
3. Move the change over valve into position “Hydraulic” (constant
regulation mode).
4. Insert an Allen key into the angle indicator bolt (see illustration)
for better visibility of the start of destroking.
5. Start the engine and adjust at pressure reducing valve (253.2 – engine1
respectively 254.2 – engine2) the X1-pressure to 13 bar.
6. Stall the hydraulic for the pump to be checked and alter the
operating pressure with the MRV up and down between 160 and
200 bar.
Start of destroking should be at an operating pressure of 180 bar,
shown at the gauge connected to the high pressure filter.
7. Re-adjust the operating pressure at the MRV to 310+10 bar and the X1-
pressure at the pressure reducing valve (253.2 – engine1 respectively
254.2 engine2) to approx. 14bar.
(For exact values refer to the final test report.)
8. Remove Allen key and gauges.
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
19
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 19
Pump Regulation System
The sense of this check is to make sure that the pump is in Q-min. position at
an operating pressure between 300 bar and 310 bar.
1. Connect a 400 bar pressure gauge to the pressure check point at the
respective high pressure filter for the pumps being checked.
2. Insert an Allen key into the angle indicator bolt (see illustration) for
better visibility of the start of destroking.
3. Start the engine, let it run with max. speed, stall the hydraulic for
the pump to be checked and alter the operating pressure with the
MRV between 280 and 310 bar.
4. The angle indicator must indicate Q-min. position at a pressure of
300 bar shown at the gauge connected to the high pressure filter.
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
20
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 20
Pump Regulation System
ã
• Turning the Q-min. stop bolt too much out can cause serious damage
to the pump.
The pump moves over 0 (zero) position into the opposite drive
direction: (suction line becomes pressure line and pressure line
becomes suction line)
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
21
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 21
Pump Regulation System
The drive train of the excavator consists of two diesel engines, several
hydraulic pumps, which supply cylinders and hydraulic motors.
The load limiting control ensures optimum use of the power required for the
excavator under varying operating conditions and avoiding overload of the
diesel engine.
Illustration Z22448b shows the principle of the electronic load limiting
control.
The MC7 (E32) processes the following input signals:
• Diesel engine speed (Pin 52, 53 and 54) from magnetic pick-up (B64-1
and B64-2), adjustment see at the end of this section.
• Switch signal (Pin 35 / 19) from engine control module (3E14-1 / 3E14-2),
24V if n > 300 min-1
The control algorithm of the load limiting control always compares the actual
engine speed with the rated load speed.
With increasing load the engine torque will rise and the engine speed will
drop.
For this reason the electronic load limiting control will be initiated when the
load speed falls below 1800 min-1 , i.e. the torque of the main pumps will be
lowered (by reducing the X1-pressure) until the rated speed of 1800 min-1 is
attained again.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
22
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 22
Pump Regulation System
The MC7 microcontroller is used for the programmable control of a maximum of four
proportional solenoids and two additional switching functions.
As input signals, the microprocessor processes analog voltages in the 0V to 5V range and
switching information. All inputs are protected against overvoltage and electrical interference.
As output signals, the output stages of the MC7 deliver closed loop controlled currents for the
connection of proportional solenoids.
The analog voltage output is suitable for the simple forwarding of analog information to other
electronic circuits.
Characteristics
• Closed loop control of solenoid currents, i.e. independent of voltage and temperature.
• Pulse width modulated (PWM) solenoid currents for minimal hysteresis.
• Internal buzzer for programmable monitoring of functions or errors.
Setting and Display Facilities
All calibration operations and the display of functions, faults and system variables are
connected via the serial interface to the BB-3 control panel or to a PC running the BODEM
software.
MC7 - Unit Dimensions
Plug Contacts
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
23
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 23
Pump Regulation System
Code
1 Working Pump 1 yes Working pump solenoid Pump has maximum Check DRE
circuit open or shorted to power valve
ground
2 Low Speed 52 no Diesel engine is not Reduction of Check
running or engine rpm too hydraulic power connection to
low or no signal from motor controller
motor controller because
of short cut or break
3 Low Speed 53 no Diesel engine is not Reduction of Check
running or engine rpm too hydraulic power connection to
low or no signal from motor controller
motor controller because
of short cut or break
4 High Speed 1 yes Diesel engine defect or Load limiting control Check
rpm too high malfunction mechanical
high idle
limitation
5 Low Battery yes Battery voltage is below Engine lug too large Check voltage
17V generator
6 MC7 Calibration yes MC7 was not pre- Adjustable current Replace MC7
calibrated at range is different
BRUENINGHAUS
HYDROMATIK
8 MC7 ADC yes Internal MC7 fault Analog input signals Replace MC7
can be wrong
9 Working Pump 2 yes Working pump solenoid Pump has maximum Check DRE
circuit open or shorted to power valve
ground
10 Low Speed 54 no Diesel engine is not Reduction of Check
running or engine rpm too hydraulic power connection to
low or no signal from motor controller
motor controller because
of short cut or break
11 High Speed 2 yes Diesel engine defect or Load limiting control Check
rpm too high malfunction mechanical
high idle
- All output ports of the MC7 are protected against short circuit.
- It is not allowed to connect 24 Volt to the output terminals.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
24
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 24
Pump Regulation System
The adjustment of the X1-pressure can be done with three different methods:
A. With 24V supply to separating terminals at the X2-switch board
or
B. With the electronic service tool (EST) BB-3 connected to the serial
interface X13 (located in the operators cab)
or
C. With a laptop, running the BODEM software, connected to the serial
interface X13 (located in the operators cab)
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
25
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 25
Pump Regulation System
1. Make sure the change over valves (253.1 – engine 1 respectively 254.1–
engine 2) are in position “Electronic Pump Regulation”
2. Connect a pressure gauge to the respective check point (M5-1 or 5-2), using a
long pressure gauge hose to be able reading the pressure in front of the X2-
panel.
3. Selection of adjusting mode:
Turn the main key switch in on position and activate the adjusting mode as
follows:
Connect 24V, simultaneously to terminal 144 and 145 for 10 seconds, using
two test leads and disconnect the voltage thereafter.
4. Selection of the engine and in turn the required
proportional solenoid valve :
With the main key switch still in on position, select the applying terminal for
proportional solenoid valve Y61-1 or Y61-2 as follows:
Motor1 →Y 61-1 → No connection to 24V required.
Motor2 →Y 61-2 → Connect permanent 24V to terminal 143, using a test lead.
5. Adjusting the X1-pressure:
Start the engine, let it run with maximum speed.
Read the pressure, required = 34± 0,5 bar
If necessary increase the X1-pressure as follows:
Connect 24V to terminal 144.
)
• As long as voltage is supplied, the X1-pressure drops to zero.
After interrupting the voltage supply, the gauge pointer will move
slowly to the new present X1-pressure.
• Example: Keeping voltage supply for two seconds , will increase the
X1-pressure of approximately 1bar.
• The adjusted value will be saved immediately and will be available
after power off.
6. To decrease the X1-pressure connect 24V to terminal 145 and proceed as
described under item 5, keeping voltage supply for two seconds , will
decrease the X1-pressure of approximately 1bar.
7. After the adjustment is finished, remove the test leads and pressure gauge and
turn the main key switch in OFF position to deactivate the adjusting mode.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
26
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 26
Pump Regulation System
Method B - With the electronic service tool (EST) BB-3 connected to the
serial interface X13 (located in the operators cab)
Pre-conditions: Normal operating temperature, correct pilot pressure setting and the
system must be free of air.
1. Make sure the change over valve is in position “Electronic Pump Regulation”
2. Connect a pressure gauge to check point M5.1 and M5.2, using long pressure gauge
hoses to be able reading the pressure inside the operators cab.
3. Connect the electronic service tool (BB-3) to the data link adapter X13,
with key switch (S1) in OFF position.
4. Turn key switch (S1) in ON position:
After switching on the power for the Control panel BB-3 the following functions are
carried out and shown on the display:
4.1 Self-test and baud rate recognition:
The BB-3 automatically recognizes the rate
of data transmission from the MC electronics.
4.2 Identification:
On recognition of the MC electronics the
relevant software in the BB-3 will be started up.
4.3 Main menu:
Initialization of remote control unit BB-3 is complete.
One of the four main menu items can be selected using the given keys.
First screen (main menu) after connection and Key switch turned ON in German.
Language selection
To change the language press simultaneously The language selection menu appears
the buttons ALT + Clear
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
27
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 27
Pump Regulation System
Method B
Cont'd:
Language selection
One of the four main menu items can be selected using the given keys. (Fig.1)
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
28
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 28
Pump Regulation System
Method B
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
29
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 29
Pump Regulation System
Method B
Cont'd:
Excavator Type selection:
Press MENU . Return to main menu. Press TEACH . Activate storage menu.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
30
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 30
Pump Regulation System
Method B
Press ENTER . Acceptance of new value Press MENU . Return to sub menu.
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
31
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 31
Pump Regulation System
Method B
Cont'd:
X1-Pressure (maximum current) Adjustment:
Press MENU . Return to main menu. Press TEACH . Activate storage menu.
If all adjustments are correct and stored in the MC7, proceed as follow:
• Stop the engine and turn key switch (S1) in OFF position
• Disconnect the electronic service tool (BB-3) and the pressure gauge.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
32
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 32
Pump Regulation System
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
33
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 33
Pump Regulation System
Method C
Cont'd:
8. The program starts (only) the first time with the Demo Version.
10. Start the program again. Now the computer is connected to the Microcontroller.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
34
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 34
Pump Regulation System
Method C
Language selection
Open menu FILE → Language , select the required language and confirm with OK .
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
35
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 35
Pump Regulation System
Method C
Open menu Display/Edit parameters → Device list , select the required Excavator type and
confirm with OK .
After confirming the Excavator type, confirm saving the parameters with OK.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
36
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 36
Pump Regulation System
Method C
Open menu Display/Edit parameters → Max current , adjust the required pressure with the
slide bar and confirm with OK .
After adjusting the pressure, confirm saving the parameters with OK.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
37
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 37
Pump Regulation System
7.3.1. General
The pilot pressure pumps (9.1 and 9.3) deliver the oil through the pressure filters
(68.1 and 68.7) to port A of the pressure relief valve (252.2) for limiting the pump
support pressure X4 to 60 bar. By the function of pressure reducing valve
(252.1), the X4 pressure of 60 bar is reduced to the pilot pressure X2 of 45 bar.
The common X2 pressure will be reduced by the function of pressure reducing
valves (253.2 – engine 1 and 254.2 – engine 2) to the necessary constant X1
pressure, to prevent the motors from overloading.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
38
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 38
Pump Regulation System
1. Connect pressure gauges to check points M11.1, M11.2, M11.3 and M11.4
at the high pressure filters.
2. Connect pressure gauges to the X1 pressure check points M5.1 and M5.2.
3. Unplug solenoid valves Y6a/b-1 + Y6a/b-2 and Y136-1 + Y136-2 to ensure
that all fans are running with maximum speed.
4. Shift the three way cock valves (253.1 and 254.1) to position “Hydraulic
(constant) Regulation Mode”.
5. Start engine 1 and let it run with max. speed.
6. Set the X1-pressure at pressure reducing valve (253.2) to approx. 4 bar **
7. Apply max. load to all pumps (e.g. extend the bucket cylinders to the stop
position until the hydraulic system stalls), and increase the pressure at all 4
MRV’s * equally to 260 bar.
Check the engine speed. Required = 1820±10 min-1
If necessary correct the X1-pressure at pressure reducing valve (253.2) until
the required engine speed is obtained. Record this pressure for other tests.
8. Stop engine 1, start engine 2 and let it run with max. speed.
9. Set the X1-pressure at pressure reducing valve (254.2) to approx. 4 bar **
10. Apply max. load to all pumps (e.g. extend the bucket cylinders to the stop
position until the hydraulic system stalls), and increase the pressure at all 4
MRV’s * equally to 260 bar.
Check the engine speed. Required = 1820±10 min-1
If necessary correct the X1-pressure at pressure reducing valve (254.2) until
the required engine speed is obtained. Record this pressure for other tests.
11. Shift the three way cock valves (253.1 and 254.1) to position “Electronic
regulation“.
12. Reset the MRV’s * to 310 bar+5bar and remove the gauges.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
39
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 39
Pump Regulation System
continued
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
40
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 40
Pump Regulation System
Cont'd:
12. Re-set the X1-pressure at pressure reducing valve (253.2 and 254.2) as
recorded **.
13. Shift the three way cock valves (253.1 and 254.1) to position “Electronic
regulation“
14. Reset the MRV’s to 310 bar+5bar , and remove the gauges.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
7.0
41
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Main Hydraulic Pumps Section 7.0
and Page 41
Pump Regulation System
ã
• Avoid pick-up contact with the fly wheel while engine running.
• The inductive AC voltage must be measured with pick up connected to
the RPM-module.
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
PC8000-6-D_Sec_7-0_#12046_rev0.doc 08.11.05
Operating Hydraulic Section 8.0
Page 1
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
8.0
2
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
Operating Hydraulic Section 8.0
Page 2
8.0 General
General information
The control blocks, the piping to the distributor manifold and the connecting
hoses to the attachment are different between the Backhoe Attachment (BHA)
and the Front Shovel Attachment (FSA). If a conversion is required, contact
the service department for further information.
Function:
) •
•
Study together with the circuit diagram.
The following numbering refers to the hydraulic circuit diagram.
Each main pump (1 to 8) delivers oil trough the high pressure filter (18.1 to 18.4)
to port P of the main control blocks (14 to 17).
This results in four main circuits.
If all spools of the control blocks (14 to 17) are in neutral position, the oil leaves
the block at port T and returns via return oil pipes (L23 to L26), return oil
collector tube, back pressure valve (26) and the return oil filters (51.1 - 51.7) into
the tank.
The function of back pressure valve (26) ensures:
- sufficient oil supply for all anticavitation valves
- and that sufficient oil is forced through the oil coolers.
If a control lever or pedal is actuated, pilot pressure oil moves the spools of the
control blocks, directing the oil flow from the main pumps to one side of the
user (either cylinders or motors). From the opposite side of the user the oil
returns to the control block and from there via the return oil circuit back into
the tank.
Each circuit is provided with one MRV (also called primary valve, at least one
SRV (also called secondary valve) and at least one flow restrictor.
continued
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
8.0
3
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
Operating Hydraulic Section 8.0
Page 3
8.0 General
Cont'd:
Function:
There are different spools in the main control blocks (I, II, III and IV) for boom
and stick installed.
Spools without a symbol (standard) are connecting the rod side of the cylinders
with the pump supply line and the piston side with the tank.
Spools with #-symbol (lowering with free pump circulation) are connecting the
piston side of the cylinders with the tank only.
Spools with $-symbol (floating) are connecting the piston side of the cylinders
with the rod side and also with the tank.
Only by lowering the boom or retracting the stick is the floating function active if
the button on the joy stick is not pushed. The piston and rod side of the respective
cylinders are in floating position direct connect to the return line (tank). By
external force the cylinder can move up or down with negligible hydraulically
resistance.
To push down the boom or retract the stick by hydraulically force, the function of
the “floating spools” must be interrupted, by activating the respective button on
the joy sticks.
Boom: S95 ON ⇒ K160 ON ⇒ Float position deactivated
S95 OFF ⇒ K160 OFF ⇒ Float position activated
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
PC8000-6-D_Sec_8-0_#12046_rev0.doc 08.11.05
Hydraulic for the Section 8.1
Page 1
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
2
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 2
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
3
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 3
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
4
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 4
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
5
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 5
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
6
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 6
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
7
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 7
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
8
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 8
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
9
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 9
Attachment Cylinders
Single movement with push button S98 depressed (Auto Float OFF)
Legend for illustration (Z 22685a):
(E20) Control lever (Joy stick)
(S98) Push button – Auto Float OFF
(-Y) Direction (axis) of joy stick
(-10V) Signal voltage (Maximum)
(gn) Colour code of signal voltage cable ( Joy stick)
(X2...) Terminal rail with number
(E48) Ramp time module
(A8 – A8c) Amplifier modules – Stick
(K58) Relay – Contacts 6/10 only closed when lifting the boom.
(K71) Relay – Contacts 6 / 10 only closed when boom up or down.
(K72) Relay – Contacts 5 / 9; 7 / 11 and 8 / 12 only closed when stick out.
(K73) Relay – Contacts 5 / 9; only closed when traveling or swinging.
(K75) Relay – Contacts 5 / 9; only closed when stick in.
(K78) Relay – Contacts 6 / 10; only closed when bucket dump.
(K80) Relay – Contacts 7 / 11 and 8 / 12; only closed when bucket fill.
(K170) Relay – Contacts 2 / 10; 3 / 11 and 4 / 12 closed in normal operating
mode.
Contacts 6 / 10; 7 / 11 and 8 / 12 closed when auto-float OFF.
(102.1 – 102.4) Remote control valves
(Y21 + Y26) Proportional solenoid valve
(Y34) Proportional solenoid valve
(Y21B+ Y26B) Directional solenoid valve
(Y34B) Directional solenoid valve
(I + II + IV) Main control blocks I + II + IV
(73) Distributor manifold
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
10
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 10
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
11
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 11
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
12
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 12
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
13
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 13
Attachment Cylinders
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
14
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 14
Attachment Cylinders
Each MRV can be checked and adjusted individually by selecting one function of the
control block circuits.
Checking:
1. Connect the gauge to the required check point M11.1 to M11.5.
2. Start the motors.
3. Lower the attachment to the ground and apply the swing parking brake
3. Extend the bucket cylinder to the stop position until the hydraulic system stalls.
4. Read the pressure. Required: 310 + 5 bar for valve blocks I – IV
If the pressure is not correct, carry out a comparative measurement with an other
function, in order to avoid wrong measuring results caused by wrongly adjusted SRV or
other defects in the system.
Adjusting:
1. Remove protection cap (a).
2. Loosen lock nut (b).
3. Turn set screw (c) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
4. Tighten lock nut (b) and install cap (a).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
15
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 15
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22691c):
Boom cylinder “Piston side” FSA
There are four service line relief valves (secondary valves) installed at the distributor
manifold (73), to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston side of the boom cylinders are protected by several
SRV’s, the pressure gauges show the pressure of that valve with the
lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
16
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 16
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22691c):
Cont'd:
Boom cylinder “Piston side” FSA
9. Adjust all four SRV’s equally, until all gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
132.1 Ì 132.2 Ì 132.3 Ì 132.4
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 132.1 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing all gauges.
) • Now all gauges will show the same value of 350 bar,
but only SRV-132.1 has the correct setting.
11. Proceed with the other valves in the same manner in the following
sequence:
132.2 Ì 132.3 Ì 132.4
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all four service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
17
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 17
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22692c):
Boom cylinder “Piston rod side” FSA
There are two service line relief valves (secondary valves) installed, in main control
blocks III and IV, to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston rod side of the boom cylinders are protected by
several SRV’s, the pressure gauges show the pressure of that valve
with the lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
18
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 18
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22692c):
Cont'd:
Boom cylinder “Piston rod side” FSA
9. Adjust both SRV’s equally, until the gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
33.4 Ì 33.8
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 33.4 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing the gauge.
) • Now all gauges will show the same value of 350 bar,
but only SRV-33.4 has the correct setting.
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
19
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 19
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22693c):
Stick cylinder “Piston side” FSA
There are four service line relief valves (secondary valves) installed at the distributor
manifold (73), to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston side of the stick cylinders are protected by several
SRV’s, the pressure gauges show the pressure of that valve with the
lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
20
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 20
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22693c):
Cont'd:
Stick cylinder “Piston side” FSA
9. Adjust all four SRV’s equally, until all gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
131.5 Ì 131.6 Ì 131.7 Ì 131.8
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 131.5 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing all gauges.
) • Now all gauges will show the same value of 350 bar,
but only SRV-131.5 has the correct setting.
11. Proceed with the other valves in the same manner in the following
sequence:
131.6 Ì 131.7 Ì 131.8
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all four service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
21
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 21
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22694c):
Stick cylinder “Piston rod side” FSA
There are two service line relief valves (secondary valves) installed, in main control
blocks I and IV, to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston rod side of the stick cylinders are protected by
several SRV’s, the pressure gauges show the pressure of that valve
with the lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
22
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 22
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22694c):
Cont'd:
Stick cylinder “Piston rod side” FSA
9. Adjust both SRV’s equally, until the gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
33.1 Ì 33.7
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 33.1 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing all gauges.
) • Now all gauges will show the same value of 350 bar,
but only SRV-33.1 has the correct setting.
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
23
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 23
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22695c):
Bucket cylinder “Piston side” FSA
There are four service line relief valves (secondary valves) installed at the distributor
manifold (73), to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston side of the bucket cylinders are protected by several
SRV’s, the pressure gauges show the pressure of that valve with the
lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
24
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 24
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22695c):
Cont'd:
Bucket cylinder “Piston side” FSA
9. Adjust all four SRV’s equally, until all gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
131.1 Ì 131.4 Ì 131.12 Ì 131.11
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 131.1 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing all gauges.
) • Now all gauges will show the same value of 350 bar,
but only SRV-131.1 has the correct setting.
11. Proceed with the other valves in the same manner in the following
sequence:
131.4 Ì 131.12 Ì 131.11
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all four service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
25
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 25
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22696c):
Bucket cylinder “Piston rod side” FSA
There are three service line relief valves (secondary valves) installed, in main control
blocks I, II and IV, to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV’s is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
)
• Since the piston side of the bucket cylinders are protected by several
SRV’s, the pressure gauges show the pressure of that valve with the
lowest setting.
Even when the gauges show the required pressure it is possible that
one or more valves have a higher setting.
• To ensure that only the SRV’s open during checks and adjustments
it is necessary to further increase the setting of the MRV’s.
7. Turn set screw (3) of the MRV’s ½ turn further in, the gauge pointers will
remain at the value shown at item #6 (350 bar + 5 bar).
8. Tighten lock nut (2) and install cap (1).
continued
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
26
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 26
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22696c):
Cont'd:
Bucket cylinder “Piston rod side” FSA
9. Adjust all SRV’s equally, until the gauges show a pressure of
360 bar.
Adjust in steps of ¼ turn, set screw (3) in the following sequence:
33.2 Ì 33.3 Ì 33.6
Remove protection cap (1) of SRV’s.
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise
to decrease pressure.
Tighten lock nut (2) and install cap (1).
10. Reduce the pressure, at SRV- 33.2 to a value below the required value,
and then increase up to the required pressure (350 bar), while
observing all gauges.
) • Now all gauges will show the same value of 350 bar,
but only SRV-33.2 has the correct setting.
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all service line relief valves.
12. Reset the MRV’s to 310 bar + 5 bar after the check / adjustment is finished,
as follows:
Remove protection cap (1).
Loosen lock nut (2).
Turn set screw (3) -clockwise to increase pressure, Counter-clock wise to
decrease pressure.
Tighten lock nut (2) and install cap (1).
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
27
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 27
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22697b):
Clam cylinder “Piston Rod side” (clam opening) FSA
There is one service line relief valve (secondary valve) installed at the distributor
manifold (73), to limit the maximum possible pressure peaks in the service line.
Since the opening pressure of the SRV is higher than the setting of the Main Relief
Valves (MRV’s) it is necessary to increase the main relief pressure for testing and
adjusting purposes.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
28
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 28
Attachment Cylinders
8.1.10 Checks and adjustments of the Service Line Relief Valves (SRV),
illustration (Z 22698b):
Clam cylinder “Piston side” (clam closing) FSA
There are two service line relief valves (secondary valves) installed in block (92), at
distributor manifold (73), to limit the maximum possible pressure in the service line
when closing the bucket.
To avoid damages at the clam shell, due to improper operation, the SRV’s should be
adjusted in a way that the pressure is just sufficient to keep the bucket closed.
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of SRV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all service line relief valves.
5. Now reduce the pressure at the SRV’s equally in steps of 5 bar until the bucket
opens by gravity (check with released pedal).
Read the pressure and increase the setting with 10%, to compensate the weight
of material stuck at the clam shell.
) • For standard buckets the pressure is 150 bar, reinforced or with heavy
wear package attached, the pressure maybe raised up to 200 bar.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
29
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 29
Attachment Cylinders
Adjustments / Checks:
1. Use a stop watch to measure the cylinder running time.
2. Raise the fully extended attachment with empty bucket to the maximum height
position (A).
3. Activate service switch S151 (located in the cab base) during the checks and
adjustments, to ensure that the main pumps are in Qmax position.
4. Rapidly move the control lever (E19) to the front end position (start the stop
watch) and hold it until the final position (B) is reached.(stop the stop watch).
ã • Lower the boom so, that the bucket stops just above the ground.
5. If the lowering speed is too high, i.e. the measured time is less than the
permissible time, the speed must be reduced by altering the throttle valves 132.1,
132.2, 132.3 and 132.4 at the distributor manifold (73).
Adjust as follows:
To decrease the lowering speed loosen lock nut (1) and turn the bolt (2) cw.
To increase the lowering speed loosen lock nut (1) and turn the bolt (2) ccw.
Since there are several valves throttling the return oil flow the valves must be set
synchronously. The adjusting screws have to be turned in by the same amount of
revolutions.
O.K.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
30
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 30
Attachment Cylinders
Adjustments / Checks:
1. Use a stop watch to measure the cylinder running time.
2. Raise the fully extended attachment with empty bucket to the maximum height
position (A).
3. Activate service switch S151 (located in the cab base) during the checks and
adjustments, to ensure that the main pumps are in Qmax position.
4. Rapidly move the control lever (E20) to the rear end position (start the stop
watch) and hold it until the final position (B) is reached.(stop the stop watch).
5. If the lowering speed is too high, i.e. the measured time is less than the
permissible time, the speed must be reduced by altering the throttle valves 131.5,
131.6, 131.7 and 131.8 at the distributor manifold (73).
Adjust as follows:
To decrease the lowering speed loosen lock nut (1) and turn the bolt (2) cw.
To increase the lowering speed loosen lock nut (1) and turn the bolt (2) ccw.
Since there are several valves throttling the return oil flow the valves must be set
synchronously. The adjusting screws have to be turned in by the same amount of
revolutions.
O.K.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
31
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 31
Attachment Cylinders
Adjustments / Checks:
1. Use a stop watch to measure the cylinder running time.
2. Raise the fully extended attachment with empty bucket to the maximum height
position (A).
3. Activate service switch S151 (located in the cab base) during the checks and
adjustments, to ensure that the main pumps are in Qmax position.
4. Rapidly move the control lever (E19) to the r.h. end position (start the stop watch)
and hold it until the final position (B) is reached.(stop the stop watch).
5. If the lowering speed is too high, i.e. the measured time is less than the
permissible time, the speed must be reduced by altering the throttle valves 131.1,
131.4, 131.11 and 131.12 at the distributor manifold (73).
Adjust as follows:
To decrease the lowering speed loosen lock nut (1) and turn the bolt (2) cw.
To increase the lowering speed loosen lock nut (1) and turn the bolt (2) ccw.
Since there are several valves throttling the return oil flow the valves must be set
synchronously. The adjusting screws have to be turned in by the same amount of
revolutions.
O.K.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
8.1
32
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Section 8.1
Page 32
Attachment Cylinders
Adjustments / Checks:
1. Use a stop watch to measure the cylinder running time.
2. Raise the fully extended attachment with empty bucket to the maximum height
position (A).
3. Activate service switch S151 (located in the cab base) during the checks and
adjustments, to ensure that the main pumps are in Qmax position.
4. Rapidly push the control pedal (E23) to the end position (start the stop watch) and
hold it until the final position (B) is reached.(stop the stop watch).
5. If the lowering speed is too high, i.e. the measured time is less than the
permissible time or uncomfortable, the speed must be reduced by altering throttle
valve 131.9 at the distributor manifold (73).
Adjust as follows:
To decrease the lowering speed loosen lock nut (1) and turn the bolt (2) cw.
To increase the lowering speed loosen lock nut (1) and turn the bolt (2) ccw.
6. Check lowering speed again and repeat the adjustment if necessary.
7. If the adjustment is finished tighten lock nut (1) and reset service switch S151.
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
PC8000-6-D_Sec_8-1_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 1
Section Page
8.2 Hydraulic for the swing circuit
8.2.1 Swing Circuit (Brief description) 2+3
8.2.2 Swing Motor 4+5
8.2.3 Swing Gear Box 6
8.2.4 Swing Parking Brake (Gear house Brake) 7
8.2.5 Swing Brake Valve 8+9
8.2.6 Electric / Hydraulic flowchart “Swing Left” 10
8.2.7 Electric / Hydraulic flowchart “Swing Right” 11
8.2.8 Checks and adjustments for the swing circuit 12 + 13
8.2.9 Function check for the hydraulic swing brake 14
8.2.10 Function check for the swing parking brake 15
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
2
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 2
continued
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
3
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 3
Cont'd.:
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
4
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 4
continued
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
5
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 5
Cont'd.:
Function:
The pressure oil inlet (A or B) and consequent oil outlet (B or A) determine
the output drive direction of the drive shaft (1).
Direction of rotation:
"Clockwise" = Direction of flow A to B
"Counter-Clockwise" = Direction of flow B to A
with view onto drive shaft!
Via the control lens (8) the oil is directed to the cylinder bores.
The piston (5) is moved from the lower (6b) to the up- per dead point (6a) by
means of the force acting on it and causes the drive shaft to rotate. On further
rotation of the drive shaft (additional pistons are pressurized) this piston is
moved towards the lower dead point again and oil of the cylinder chamber is
forced out through the kidney formed openings of the control lens. This oil is
fed back to the tank via the return line.
If the supply and return line is changed it changes the output drive direction
of the drive shaft.
By means of the angled arrangement of the cylinder (7) (bent axis design), a
certain piston stroke is produced which results in a fixed displacement per
revolution of the drive shaft. According to the size of the applied flow this
produces a specific output speed.
The output torque at the drive shaft is dependent on the size of the motor and
the required operating pressure.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
6
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 6
The swing gear is of compact design with a two stage planetary gear including a
multi disk house brake.
The gear is bolted to the superstructure and fits firmly due to the machined
diameter (A) and the bolt torque.
The torque loaded on the hydraulic motor is transmitted by drive shafts (2)
and sun gear shaft (3) to the first planetary stage (17).
The sun shaft (17) of the first planetary stage transmits the torque into the
second planetary stage (19). By the planetary gears the output drive shaft is
rotated and transmits the torque to the pinion (21).
The drive housing, and the gearbox are filled with gear oil.
Aeration is done by breather filters.
To lubricate the pinion bearing port (22) is connected to the central
lubrication system.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
7
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 7
Function:
Brake applied:
The outer disks (4) engaged to the housing by serration and the inner disks (3) in
serrated connection with drive shaft (12) are pressed together by the springs (9).
This results in a fixed connection between housing and drive shaft.
Brake released:
Oil pressure via port (13) reaches the bottom of the piston (6) and forces the
piston upwards against the thrust washer (10).
This function eliminates the spring force onto the disks so that the sinus
(spacing) rings can keep the outer disks (4) apart, thus the brake is released.
The releasing pressure is 19 - 20 bar, the maximum permissible pressure
60 bar.
This is a so named "Wet Brake" because the brake housing is splash lubricated
by gear oil.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
8
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 8
Ports:
(Y) Leak oil
(T) Return oil
(A) Service line from control block
(A1) Service line to the motor
(B) Service line from control block
(B1) Service line to the motor
continued
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
9
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 9
Cont'd.:
If after a swing motion the joy stick is put into neutral position without
using the foot brake, the superstructure is turned by inertial force and the
hydraulic motor acts as a pump because it is driven by the swing gear.
In this period the pressure in the service line is lower than the pressure in
the return line, because there is a back pressure valve at the tank, and oil is
forced through the anti-cavitation valves into the service line.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
10
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 10
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
11
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 11
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
12
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 12
)
• It is important that the complete MRV-valve and the Pressure
Increasing Valve is firmly (with 300 Nm) tightened. Otherwise,
internal leaks could occur which result in problems of correct
adjustment, loud flow noises and high temperatures.
• Whenever pressure checks are carried out, they must be carried out
for all swing motors, to make sure the control lines and the check
valves in the brake valve blocks are in good condition.
• Because the Swing motors are working hydraulically in combined
operation, the pressure gauge shows the pressure of the pressure
increasing valve with the lowest setting. Even when the gauge shows
the required pressure it is possible that one valve has a higher setting.
Therefore lower the pressure on one valve below the required pressure
and then increase up to required pressure. Proceed with next valves in
the same manner.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
13
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 13
Low pressure check / adjustment [Swinging down path (drifting) with still disconnected pilot pressure line]
9. Actuate either L.H. or R.H. rotation until the hydraulic system stalls.
a) Loosen lock nut (3) of all (PIV’s) and reduce the pressure equally with
set screws (4) to a value of about 130 bar, secure setting with lock nut (3)
b) Loosen lock nut (3) of the first PIV (49.1).
c) Reduce the pressure with set screw (4) of PIV (49.1) to a value of about
110 bar, and then increase up to the required pressure of 120 bar.
d) Secure adjusted set screw (4) by tightening lock nut (3)
e) Loosen lock nut (3) of the second PIV (49.2).
f) Reduce the pressure with set screw (4) of PIV (49.2) to a value of about
110 bar, and then increase up to the required pressure of 120 bar.
g) Secure adjusted set screw (4) by tightening lock nut (3)
h) Loosen lock nut (3) of the third PIV (49.3).
i) Reduce the pressure with set screw (4) of PIV (49.3) to a value of about
110 bar, and then increase up to the required pressure of 120 bar.
j) Secure adjusted set screw (4) by tightening lock nut (3)
10. Re-connect the pilot pressure line.
11. Re-set MRV-pressure and remove the gauges after the check / adjustment is
finished
ã
• Strong pulsation of the return line hoses, indicates deviation in
opening pressure of PIV’s and must be avoided.
Repeat the adjusting procedure until the oil returns well-balanced
via all three pressure increasing valves.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
14
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 14
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
8.2
15
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Swing Circuit Section 8.2
Page 15
4. Actuate either L.H. or R.H. rotation, the machine should not turn.
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
PC8000-6-D_Sec_8-2_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 1
Section Page
8.3 Hydraulic for the travel circuit
8.3.1 Travel Circuit (Brief description) 2+3
8.3.2 Travel Motor 4
8.3.3 Rotary distributor 5
8.3.4 Travel Gear Box 6
8.3.5 Travel Parking Brake (Gear house Brake) 7
8.3.6 Travel Brake Valve 8
8.3.7 Electric / Hydraulic flowchart “Travel forward” 9
8.3.8 Electric / Hydraulic flowchart “Travel backward” 10
8.3.9 Checks and adjustments for the travel circuit 11
8.3.10 Function check for the travel parking brake 12
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
2
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 2
continued
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
3
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 3
Cont'd.:
Illustration (Z 22717a):
Brief description (Service circuits)
(Study together with the hydraulic and electric circuit diagram).
The L.H. travel motors (21.1 + 21.2) are driven by the pumps (2 + 6) and the
R.H. travel motors (21.3 + 21.4) are driven by the pumps (3 + 7).
The oil flows from the pumps through the high pressure filters to the control
blocks (I + III).
In neutral position of the spools the oil flows via the return oil lines (L23 +
L25) into the collector tube and further to the tank.
On its way to tank the oil must flow through the back pressure valve (26) and
the return oil filter (51.1 - 51.7). (Back pressure valve function see section 4.)
When operating the foot pedal for "Travelling" the pump line of each control
block is connected with the corresponding service line (A1 or B1) via the
rotary distributor (21) and travel brake valves (39.1 + 39.2) to the travel
motors (22.1 – 22.4).
The travel brake valve acts as a flow control valve in order to avoid the travel
motors picking up speed when travelling downhill.
Each travel gear includes a spring loaded multi disk brakes (House brakes 77.1 –
77.4). They are used as parking brakes, automatically applied by the function of
Y16 whenever the prime mover is switched OFF.
The brake release pressure (X2 pressure reduced to 35 bar by valve 147) is
monitored by the pressure switch (B48).
The leak oil (case drain) flows through the line (L38) and the leak oil filter (66)
back to tank.
Function:
The line from port T of the control blocks is connected to the return oil pipe
at the tank. Due to the adjustment of the back pressure valve (26) there is
under any circumstance enough oil under pressure available at the anti
cavitation valves. Any time the pressure in the service line to the motors is
less than the back pressure additional oil is forced through the anti cavitation
valves into the circuit.
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
4
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 4
If the supply and return line is changed it changes the output drive direction
of the drive shaft.
By means of the angled arrangement of the cylinder (7) (bent axis design), a
certain piston stroke is produced which results in a fixed displacement per
revolution of the drive shaft. According to the size of the applied flow this
produces a specific output speed.
The output torque at the drive shaft is dependent on the size of the motor and
the required operating pressure.
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
5
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 5
Task:
The rotary distributor (joint) permits a hydraulic connection between the
superstructure and the under- carriage, that means between the rotating and the
stationary part.
Function:
During operation superstructure and under carriage constantly rotate towards each
other. Nevertheless, the travel oil motors must be supplied with hydraulic oil in
every position in which the superstructure is moved in regard to the undercarriage.
Oil is directed by the control blocks to the ports (A-D) of the housing (1).
The oil flows to the outlet ports (A-D), of the rotor (2), via ring grooves as well as
longitudinal and cross holes. The rotor is bolted to the under carriage. The sealing
of the ring grooves among one another is done by sealing elements (6/7).
The hydraulic connection for return, case drain, house brake and the track
tensioning cylinders is done via the ports (K1/K2), (L), (St) and (St).
The entering of dirt gets blocked by the half disks (9) and the collar of mover (3)
(Principe of labyrinth sealing). Both areas are connected via grease nipple (20) to
the central lubrication system which causes an additional sealing. The rotor (2) is
at the top and bottom section guided in the housing by the guide rings (8).
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
6
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 6
The travel gear consists of one spur gear set and two planetary stages.
The travel gearbox is fitted to the side frame with bolts.
Function:
The spur gear (9/10) is driven by two hydraulic motors via the input drive
shafts (11, see illustration Z21389 on the following page).
The 1. planetary gear (7) is driven by the shaft (15) which is connected to the
spur gear.
The planetary gear supports themselves in the internal geared wheel (8)
which causes that the 2. planetary gear (2) is driven by the shaft (12).
The sprocket drive shaft is driven via the splines of the planetary carrier (2).
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
7
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 7
Function:
Brake applied:
The outer disks (99) engaged to the housing (96) by serration and the inner
disks (99) in serration connection with the drive shaft (11) are pressed together
by the springs (90). This results in a fixed connection between housing (96) and
shaft (11).
Brake released:
Oil pressure via port (93) reaches the bottom of the piston (91) and forces the
piston against the retainer (100).
This function eliminates the spring force onto the disks thus the brake is
released.
The releasing pressure is 21 - 23 bar, the maximum permissible pressure 50 bar.
This is a so named "Wet Brake" because the brake housing is filled with gear oil.
The oil must be filled in after removing the filler plug (97) up to the edge of the
level control plug (94) thread.
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
8
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 8
Illustration Z 21695
Task:
Travel brake valves control the oil flow from the hydraulic motor to the tank
depending on operating pressure. This braking action prevents the motors from
over speeding.
Function:
Spring force keeps the spool in the lowest flow position. with increasing
operating pressure the opening for the return oil flow becomes larger.
On its way to the hydraulic motor the oil flows from A to A1 respectively from
B to B1 depending on the selected travel motion.
Example:
Operating pressure at port A moves spool (1) against the force of the spring (2)
and opens the way for the return oil (B1 to B).
Check valve (3) prevents a direct oil flow from B1 to B.
If the operating pressure decreases to such an extend that the spring force
overcomes the pressure, the flow to the tank becomes restricted, resulting in
braking of the machine.
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
9
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 9
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
10
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 10
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
11
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 11
2. Unplug solenoid valve Y16 (located at the central control and filter panel)
to keep the parking brake applied.
3. Start both motors.
4. Engage carefully the desired travel motion and keep the pedal in final
position to built up max. pressure.
5. Increase slowly the MRV-pressure while observing the pressure gauge.
Gauge value must remain at 310bar + 5bar.
If the gauge shows a smaller or greater value the SRV must be adjusted
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
8.3
12
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic for the Travel Circuit Section 8.3
Page 12
5. Reconnect plug connection to solenoid valve Y16, now the travel function must
be possible again and the monitor returns to standard display.
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
PC8000-6-D_Sec_8-3_#12046_rev0.doc 10.11.05
Hydraulic Track Tensioning System Section 9.0
Page 1
Section Page
9.0 Hydraulic Track Tensioning System
General 2
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
2
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 2
9.0 General:
The hydraulic track tensioning system ensures automatically the correct track
tension.
The pilot pressure pumps (9.1 and 9.3) will supply oil to all four tensioning
cylinders (124.1 – 124.4).
The maximum pressure is limited by pressure increasing valves (141).
The pressure in the tensioning cylinders transmits the required force to move
the guide wheels to the front, until the correct track tension is obtained.
External forces acting at the guide wheels will be absorbed through the
pressure accumulators (119.1 + 119.2, first stage) and (120.1 – 120.4, second
stage).
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
3
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 3
The oil flow of the pilot pressure pumps (9.1 + 9.3), filtered by pressure filters
(68.1 + 68.7) enters port "P" of solenoid valve Y16, via the common pilot
pressure supply line (45 bar) of the central control and filter panel (36).
If solenoid valve Y16 is actuated (i.e. pressure at sensor B48), the oil for the
travel parking brake (reduced to 35 bar by the function of valve 147), flows via
rotary joint (21), shut-off cock (118.1), the orifice, the two check valves (121.1 +
121.2) and the shut-off cocks (118.2 + 118.3) the into the tensioning cylinders
(124.1 – 124.4).
The resulting force moves the guide wheels toward the front, until the correct
track tension is obtained.
Simultaneously the system is via check valves (125.1 + 125.2) connected to the
pressure increasing valve (141).
External forces acting at the guide wheels will be absorbed through the pressure
accumulators (119.1 + 119.2, first stage) and (120.1 – 120.4, second stage).
continued
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
4
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 4
Illustration (Z 22757a):
Cushioning Function
When the tensioning cylinders (124.1 – 124.4) are moved in by external
forces, the none return valves (121.1 + 121.2) will be closed.
A certain amount from the displaced oil of the tensioning cylinders is taken
up by the pressure accumulators.
First stage: at a pressure higher than 31 bar, oil is taken up by the side frame
accumulators (119.1 + 119.2).
Second stage: at a pressure higher than 150 bar, oil is taken up by the center
section accumulators (120.1 – 120.4).
The system pressure can rise up to 310 bar pressure increasing valve (141)
setting.
With reduction of external forces, the oil is pushed back by the accumulator
pressure into the tensioning cylinders.
If the displaced oil volume was higher than the accumulators could take up,
oil is added from the pilot pressure circuit, as soon as the pressure in the lines
to the tensioning cylinder is lower than 35 bar.
To avoid serious damages to the pilot pressure system in case of a faulty
check valve, pressure relief valve (257.1) with a 55 bar setting is installed.
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
5
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 5
Function:
The valve poppet (2) is connected via the jet bores (11) and (12) with the P
port.
If static pressure increases above the set pressure value, the valve poppet (2)
opens and allows oil to flow freely to tank (T1). This oil generates a pressure
drop in the spring chamber of the main spool, the closing force of the spring
(6) is cancelled, and the main piston (5) opens to allow the pump flow to flow
to tank (T2).
Damped opening and closing is obtained by the throttled volumetric change.
By applying external pressure of Pst max = 60 bar to the main spool (9) via
port X, the pre-tensioning of the pressure spring (3) is increased by the amount
of the piston stroke "S" and system pressure is increased correspondingly.
The setting is fixed by means of the setting screw (7) and lock nut (13); 1 turn
of the screw ~ 150 bar.
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
6
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 6
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
7
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 7
Checking / Setting the 55 bar pressure relief valve (257.1) – safety valve
1. Connect pressure gauges to check point M1.1 + M1.2 + M9.1
2. Start the both motors.
3. Check the X4-pressure at M1.1, required 60 bar.
If necessary correct the setting by the function of valve 252.1 as follow:
a) Loosen lock nut (1).
b) Set pressure with set screw (2).
c) Tighten lock nut (1).
4. Unplug solenoid valve Y16.
5. Increase the pilot pressure X2 by the function of valve 252.2 to ~ 60 bar.
a) Loosen lock nut (3).
b) Set pressure with set screw (4).
c) Tighten lock nut (3).
6. Check the Safety-pressure at M9.1, required 55bar.
If necessary correct the setting by the function of valve 257.1 as follow:
a) Loosen lock nut (5).
b) Set pressure with set screw (6).
c) Tighten lock nut (5).
7. Re-connect solenoid valve Y16.
8. Re-set the X2-pressure to 45 bar by the function of valve 252.2
Checking / Setting the 35 bar pressure reducing valve (147) – supply pressure
1. Connect a pressure gauge to check point M9.2.
2. Start the both motors.
3. Read pressure, required = 35+2 bar
If readjustment is required proceed as follow
a) remove dust cap (a) and loosen lock nut (b).
b) Set pressure with set screw (c).
c) Tighten lock nut (b) and re-install cap (a).
continued
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
8
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 8
continued
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
9
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 9
W
The maximum pressure will be shown only after the accumulators are
completely filled with oil.
When the pressure reaches the pre-charge gas pressure ( 31 bar and
150 bar) the gauge pointer moves slower depending on the gas
compression.
If the gauge shows a lower or higher value the pressure increasing valve
must be adjusted.
Setting procedure, high pressure stage (Valve 141)
a) Loosen lock nut (2).
b) Adjust pressure with set screw (3).
c) Secure adjustment by tightening lock nut (2).
d) Re-check pressure setting.
11. The low pressure setting of the pressure increasing valve must now be
reset (with the pilot pressure line at port X still disconnected):
Setting procedure, low pressure stage (Valve 141)
a) Stall the hydraulic with the clam opening function (clam cylinders
completely retracted) and observe pressure at check point M29.4.
b) loosen lock nut (4) and turn set screw (5) ccw until gauge at
check-point M29.8 shows 35 bar.
c) Tighten lock nut (4).
d) Re-check pressure setting.
continued
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
9.0
10
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Hydraulic Track Tensioning System Section 9.0
Page 10
If the pressure remains the at a higher or lower pressure*, re-adjust the low
pressure setting at the pressure increasing valve (141).
) * The pressure may drop below 35 bar after a longer time, this is o.k.
because of internal leakage.
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
PC8000-6-D_Sec_9-0_#12046_rev0.doc 14.11.05
Access ladder Section 10.0
Page 1
hydraulically operated
Section Page
10.0 Access ladder hydraulically operated
10.0 General 2
10.1 Function of hydraulically operated access ladder 3+4
10.2 Adjustments / Checks 5
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
10.0
2
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
Access ladder Section 10.0
Page 2
hydraulically operated
General
The access ladder is hydraulically operated by the hydraulic cylinder (Z) with
the pilot pressure X4 of 60 bar. The movement of the ladder is controlled by
the function of switch:
S84: => Lowering the ladder
S84B => Lifting the ladder
Lifting the ladder is only possible with the engine running. The lowering
movement is possible by hydraulic force with the engine running or by the
force of gravity with the engine at stand sill.
) If the ladder is not in the final upper position the pilot control is
switched off and solenoid valve Y120 activates the hydraulic swing
brake. The display in the operators cab shows a message.
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
10.0
3
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
Access ladder Section 10
Page 3
hydraulically operated
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
Access ladder Section 10.0
Page 4
hydraulically operated
Cont'd:
Prime drive is not running and the ladder is in the “final upper position”
With switch S84 activated in position 2 (ladder down) solenoid valve Y123B
and relay K132 are active. Y123B connects the piston side of the cylinder to
the return line and K132 activates Y125, so that the oil can return without
resistance to the tank. Now the ladder can move down only by its own mass
(due to the force of gravity). The operator has to push the ladder slightly until
it starts moving down by its own weight.
The rod site of the cylinder receives oil via anti-cavitation valve (258.5).
It is not necessary to activate the key switch, because the involved
components are directly battery supplied via fuse F17.
There is an additional pull switch S84A below the ladder support. With this
switch activated the ladder can moved down from the ground.
• Make sure that there are no obstacles in the moving range of the
ladder. Stop raising the ladder by releasing the control switch (S84) if
there are any obstacles in the moving range.
• Mount the ladder only in completely lowered position.
• Do not lift persons or objects (tools) with the hydraulic access ladder.
Serious injury or death could occur.
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
10.0
5
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
Access ladder Section 10.0
Page 5
hydraulically operated
Checking / Setting the 70 bar pressure relief valve (258.3) – safety valve
1. Connect pressure gauges to check point M1.1 and M37.1.
2. Start both engines.
3. Lift the ladder to the final upper (working) position, using switch (S84B)
4. Check the X4-pressure at M1.1 and M37.1, required 60 bar.
5. Increase slowly the X4-pressure, by turning in set screws (2) of pressure
relieve valve (252.2), while observing the pressure gauges. Stop as soon
the pressure does not raise any further.
The gauge pointers should remain at 70 bar ± 2 bar.
6. If necessary correct the setting as follow:
a) Turn set screw (2) of valve (252.2) a ½ turn further in, the gauge
pointers will remain at the value shown under item #5
b) Set the pressure of 70 bar ± 2 bar with set screw (4) at valve (258.3).
c) Tighten lock nut (3).
7. Reset valve (252.2) to 60 bar and tighten lock nut (1), adjustment is finished.
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
PC8000-6-D_Sec_10-0_#12046_rev0.doc 14.11.05
Central refilling system Section 11.0
Hydraulic operated refilling arm Page 1
Section Page
11.0 Central refilling system (Hydraulic operated refilling arm)
11.0 General 2
11.1 Function 3
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
11.0
2
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
Central refilling system Section 11.0
Hydraulic operated refilling arm Page 2
The excavator is equipped with a central refilling system for easy service and
maintenance. One part of this system is the movable refilling arm. This arm is
hydraulically driven by cylinder (C) and mounted below the power frame.
The refilling arm can moved up or down by pull switch S23 (D) only when the
engine is running and the enable switch S94 (E) is turned to ON position “1”.
For correct operation of the refilling arm see OPERATION MANUAL:
) If the refilling arm moves out of its upper position the pilot control will
stop all working functions and activate the swing brake. The text
display show a message.
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
11.0
3
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
Central refilling system Section 11.0
Hydraulic operated refilling arm Page 3
The pumps (9.1) and (9.3) are delivering oil through filter (68.1) and (68.7) to
port A of pressure relief valve (252.2).
The pressure relief valve (252.2) maintains the adjusted pressure of 60 bar, called
„X4“-pressure, and is present at port P of solenoid valve Y124A/B.
If the solenoid valves Y124A together with solenoid valve Y124C is energised
pressurised oil flows to the arm cylinder piston side and the refilling arm will
move up. If the solenoid valves Y124B together with solenoid valve Y124C is
energised pressurised oil flows to the arm cylinder rod side and the refilling arm
will move down.
Solenoid valve Y124C act as a security lock to prevent a uncontrolled down
moving of the refilling arm. This valve is a special 100% leek oil free valve.
All solenoid valves Y124A/B and C are PLC controlled. Control switch B (S87)
is connected to the PLC and act as a remote control. The refilling arm can only
moved down or up with the enable switch S94 (E) turned to ON position “1”.
Only moving down is possible by gravity with engines stand still and key switch
S1 activated.
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
PC8000-6-D_Sec_11-0_#12046_rev0.doc 15.11.05
Hints for reading the Section 12.0
Page 1
Hydraulic Circuit Diagram
Section Page
12.0 Hints for reading the hydraulic circuit diagram
General 2+3+4
12.1 Symbols 5
12.1.1 Lines, unions 5+6
12.1.2 Components, valves 7
12.1.3 Sensors 8
12.1.4 Valves, valve components 9+10+11+12
12.1.5 Pumps, motors, cylinders 13 +14
12.1.6 Assemblies and main components 15+16
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
2
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 3
Hydraulic Circuit Diagram
12.0 General:
) •
•
The illustrations are used for exemplary explanations only.
Use original circuit diagram for detailed reading
• There are more symbols on the following pages shown as in the
diagrams drawn. Some symbols of the diagrams not shown in the
following pages.
A Diagram No. and Type of the 897 895 40 a Diagram No. only for the
respective machine PC8000-E respective machine
B Respective Serial No. 12041
C Sheet-No. / Quantity of sheets 01 / 04 1st of four sheets
D Co-ordinates to describe the 1 C 10 Page 1 on co-ordinate C vertical
location of a component and 10 horizontal Remote control
valve 102.1
E Component-No. 127 127 Main control block I
F Line-No. with cross hint, L37/3B9 Case drain line (Line No.37)
comes from / goes to sheet 2
coordinate E7
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
4
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 5
Hydraulic Circuit Diagram
12.1 Symbols
Illustration Z 22988a
12.1.1 Lines, unions
Symbol Description Used as / at / on
1 Oil supply line, can be a Suction line or pressurized
hose or a pipe. line of main hydraulic circuit
or pilot pressure circuit or
auxiliary circuits (e.g. fan
drive).
2 Return oil line, can be a Return lines, connected to
hose or a pipe. the return oil filter chamber
of the main oil reservoir.
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
6
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 7
Hydraulic Circuit Diagram
12.1 Symbols
continued
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
8
12.1 Symbols
12.1.3 Sensors
Symbol Description Used as / at / on
20 Pressure switch / sensor e.g. return / leak oil
Input = pressure chamber (digital), high
Output = electrical signal pressure filter (analogue)
analogue or digital
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 9
Hydraulic Circuit Diagram
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
10
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 11
Hydraulic Circuit Diagram
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
12
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 13
Hydraulic Circuit Diagram
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
14
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 12.0
Page 15
Hydraulic Circuit Diagram
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
12.0
16
12.1 Symbols
16.11.05 PC8000-6-D_Sec_12-0_#12046_rev0.doc
Hints for reading the Section 13.0
Electric Circuit Diagram Page 1
Section Page
13.0 Hints for reading the electric circuit diagram
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 2
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
3
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 3
13.2 Symbols
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
4
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 4
13.2 Symbols
31) Rectifier bridge 32) Thermal over load limit 33) Phase, 4-wire system
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
5
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 5
Each sheet is numbered from 8 (at the left corner) to 1 (at the right corner) along the
top and bottom lines, and lettered down from F (at the top) to A (at the bottom)
along the left and right side lines.
This coordinate system enables you to find components easily.
On the table of contents, page one, the individual circuits are listed up with the
respective page number.
Example: The circuit for the superstructure lighting is shown on page 39.
Pages number two, three and four are cross reference lists of component codes
related to page numbers.
Example: The relay with the component code “K1-1” is shown on page 8.
All electrical components are connected via cable harnesses to the main switch
board “X2”. There is only one Plug connector in between, which is always located
close to the respective component like sensors, solenoids etc.
All 24 volt wires are blue and have a printed code (every 10 cm) at each end of the
wire. (see illustration)
The first part of the code shows the required connection and the second part gives
the information what is connected at the other side of the wire.
Example:
going to coming from coming from going to
All circuits are shown current less and all relays and switches are in neutral position.
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
6
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 6
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
7
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 7
When diodes are fitted to a relay, they are fitted to allow a current flow in one
direction only. An LED* (Light Emitting Diode) indicates a current flow if it
lights up.
When diodes ** are fitted anti-parallel to a relay coil, they absorb the high
induced voltage caused by making and breaking the current flow through the
coil.
This occurs each time we operate a switch supplying current to the coil. The
diode effect allows the induced current to circulate within the coil windings and
decay when the energy to the coil is cut.
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
13.0
8
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Hints for reading the Section 13.0
Electric Circuit Diagram Page 8
Cont.:
13.4 Reading a Circuit Diagram.
b. F11 / 10.5 = Power line F11, comes from circuit breaker F11, sheet
08 section 8 and continues on sheet 10 section 5.
c. S27 / 20.7 = Line S27, comes from switch S27, sheet 08 section 1
and continues on sheet 20 section 7.
Function:
If switch S27 is actuated, terminal A and B are connected and 24VDC will
energize the coils of K121 and K121a on page 08 and simultaneously via line
S27 a digital input to the PLC on sheet 20 section 7.
Now the machine can be operated in emergency mode and a warning text
appears on the display.
PC8000-6-D_Sec_13-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 1
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
2
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 2
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
3
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 3
14.1.2 Task
The PLC receives from the monitored excavator components the actual
values and does an evaluation.
The evaluation results in a control and display function.
See I / O connection table (chapter 10) and electric circuit diagram for I / O
levels and ports.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
4
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 4
) • The quantity and configuration of the BIM and ANM Module can be
vary, depend on the excavator type and additional options.
MK-LED, The short circuit marker are used to indicate an external short to GND
• MK1, MK3, MK5, MK7 & MK9- LED for outputs A1.1 - A1.8
A3.1 - A3.8, A5.1 - A5.8, A7.1 - A7.8 & A13.1 – A13.8
• MK2, MK4 , MK6, MK8 and MK10 if there groups as outputs used
• A MK-marker is placed, if an output (e.g. A1.1) gets from the program an output signal
and at the same output happens an external short. The red MK 1-LED lights ON
)
• If there is a short all outputs of the resp. Output group i.e.. A1.1 - A1.8)
are switched Off
• The short circuit marker remains until the control system gets switched
Off/ON (after eliminating the short).
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 5
Boolean algebra Mathematical rules for binary variables and conditions. For Boolean
equations the following signs are used:
Logical AND operation (AND or &) ∧
Logical OR operation (OR or >=1) ∨
Logical Negation (NOT or 0) ¬
Byte Unit for Information unit comprised of 8 bits. A byte can assume a value
between 0 and 255.
Word Memory unit comprised of 2 byte or 16 bit. A word covers the numeric
range from –32767 to +32767.
RAM Random Access Memory: Read-write memory in which each memory cell
can be addressed in order to read, write or delete at any time. RAM losses
all of its information when the computer is turned off which is why it is
often buffered by accumulators or batteries.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 6
Cont'd:
EEPROM Electrically Erasable Programmable Read-Only Memory (also called
E2PROM):Electrically erasable and programmable memory. In the event
of a power failure, the contents of this type of memory remain intact. The
DIGSY plus ® application program (AWP) is loaded into this type of
memory.
Cycle Time Time required for the application program to run through once.
continued
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 7
Cont'd:
Numeral A value expressed in one digit: from 0 to 9 in the decimal system and 0-F
in the hexadecimal system.
Baud Unit used in serial transmission of data: bits per second (bit/s).
Binary Numbers, data and information which are exclusively expressed using
the two values 0 and 1 are bivalent = binary dates and information,
exclusive with the use of digits 0 and 1 (e.g. 1 = current 0 = no current).
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 8
Keep in mind
• - BE CAREFUL
• - BE ALERT
• - THINK ABOUT WHAT YOU ARE DOING
Any PERSON doing any work in or around the machine must be familiar
with the local SAFETY INSTRUCTIONS and with the specific SAFETY
INSTRUCTIONS REGARDING TO HIS OCCUPATION.
Qualified persons in sense of the safety relevant hints in this manual or on the
product, are persons which are
• either as project engaged person familiar with the safety concept for
automatic control systems;
• or as operating personal for the use of an automatic control system being
instructed;
• or having the authorization and occupation to put such systems into operation
or doing repair work as well as having the authorization and occupation to put
such systems/units into operation regarding the power
circuits and there safety standards and, to earth and to mark it.
continued
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 9
• Replace the fuses only by fuses which matches the values given in the
technical dates
ã • Do not through batteries into open flame and do not solder at their cell
body, explosion can occur (max. Temperature 100° C). Do not open and
do not recharge batteries that contain lithium or mercury. Replace
them by same type only!
• Dispose batteries and accumulators as special waste.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
10
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 10
The DIGSY plus performs by the function of the Status LED’s (5V and DIAG) and
the so named Diagnostic Words* (DW1 up to DW256) many data and statuses.
With a PC and the Program- and Diagnostic Software the. Diagnostic Words are
visible on a monitor.
The following sections explain the diagnostic possibilities more in detail.
* Can be called-up by PC assistance only.
LED defect *)
(if DIAG
LED is ON)
others *)
5 V-LED
flashing
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
11
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 11
EEPROM- or Initialize
RAM- fault EEPROM *1)
if the fault is
still present *2)
DIAG-LED Program Program Start program *1)
OFF not running stopped
(except LED
defect)No Program Load program *1)
otherwise LED
defect *2)
DIAG Program- Communication via
flashing state Interface COM-SP
unchanged or COM-SK active
Color State COM-SP⇔ Text
depending Display
COM-SK⇔ (PC)
*1) Function of the Programming Software PROSYD
*2) = Return PLC to manufacturer
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
12
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 12
The short circuit markers are used to indicate a short of the outputs at an external
short to GND.
A “MK” marker will be initialized if by the user-program an output signal is
given and at the same output is an external short present.
The “MK” marker remains until (after short elimination) the control system is
switched OFF and ON.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
13
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 13
For the function control a two-color LED is used, visible at the front cover.
The diagnostic - LED indicates following states:
- LED red: System in reset mode or range overflow of
one or more analog outputs.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 14
) • .This is an example for the first Slot. Additional BIM Modules can
be vary depend on configuration of the variable input/output port
A2/E9/ A4E10, A6/E11, A8/E12 or A14/E21.
• The configuration for the respective excavator is written in the
EA-Configuration chart (EA-Belegungsliste) see Appendix.
continued
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 15
Cont’d.:
Pin Symbol Operand Definition
22 Output 1.1 A 1.1 Output 1 of the output group 1
23 Output 1.2 A 1.2 Output 2 of the output group 1
24 Output 1.3 A 1.3 Output 3 of the output group 1
25 Output 1.4 A 1.4 Output 4 of the output group 1
26 Output 1.5 A 1.5 Output 5 of the output group 1
27 Output 1.6 A 1.6 Output 6 of the output group 1
28 Output 1.7 A 1.7 Output 7 of the output group 1
29 Output 1.8 A1.8 Output 8 of the output group 1
30 UE/A Under Load Voltage UE/A =
31 UE/A Under Load Voltage Voltage.
32 UE/A Under Load Voltage Input / Output
33 UCPU DIGSY (plus)- Operation Voltage
34 Input 2.1 E 2.1 Input 1 of the input group 2
35 Input 2.3 E 2.3 Input 3 of the input group 2
36 Input 2.5 E 2.5 Input 5 of the input group 2
37 Input 2.7 E 2.7 Input 7 of the input group 2
38 Output 1.1 A 1.1 Output 1 of the output group 1
39 Output 1.2 A 1.2 Output 2 of the output group 1
40 Output 1.3 A 1.3 Output 3 of the output group 1
41 Output1.4 A 1.4 Output 4 of the output group 1
42 Output1.5 A 1.5 Output 5 of the output group 1
43 Output 1.6 A 1.6 Output 6 of the output group 1
44 Output 1.7 A 1.7 Output 7 of the output group 1
45 Output 1.8 A1.8 Output 8 of the output group 1
46 UE/A Under Load Voltage
47 UE/A Under Load Voltage
48 UE/A Under Load Voltage
49 UCPU DIGSY (plus)- Operation Voltage.
50 0 V (GND) Ground / GND
There are two pins (two channels) parallel connected only for output A1.1 –
A1.8 (the same for additional boards A3, A5, A7, A13).
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 16
) • .This is an example for the first ANM slot. Additional ANM modules
configuration can be vary depend on configuration (temperature or
pressure).
• The configuration for the respective excavator is written in the EA-
Configuration chart (EA-Belegungsliste) see Appendix and the
respective electric diagram.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 17
Cont’d.:
PIN PIN-NAME OPERAND COMMENTARY
26 A1G GND - Output 1
27 4U+E4G GND - Input 4
28 A2G GND - Output 2
29 E3G GND - Input 3
30 A3G GND - Output 3
31 E2G GND - Input 2
32 A4G GND - Output 4
33 E1G GND - Input 1
34 GND/ANA Analogues – GND
35 E8 EW Z+1.4 Input (U/I) 8
36 GND/ANA Analogues – GND
37 E7 EW Z +1.3 Input (U/I) 7
38 GND/ANA Analogues – GND
39 E6 EW Z +1.3 Input (U/I) 6
40 GND/ANA Analogues – GND
41 E5 EW Z +1.3 Input (U/I) 5
42 A1G GND – Output 1
43 E4 EW Z.4 Input (U/I) 4
44 E4 EW Z.4 Input (U/I) 4
45 E3 EW Z.3 Input (U/I) 3
46 E3 EW Z.3 Input (U/I) 3
47 E2 EW Z.2 Input (U/I) 2
48 E2 EW Z.2 Input (U/I) 2
49 E1 EW Z.1 Input (U/I) 1
50 E1 EW Z.1 Input (U/I) 1
• All pins are internal connected
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 18
Attention: The complete shield of the analog cable must be connected to the ground
(GND) bolt of the PLC housing. This bolt must be connected to the X2
frame / machine ground by a cable (as short as possible) with 2,5 mm2
cross section.
When using plug connectors with metal boxes and connected shield the
additional complete shielding of the analog cable with the ground bolt is
not necessary. But attention must be played that the metal box is connected
by screws with the PLC housing.
The twisted signal lines are pair wise shielded and already via the 50-pol
female part of the connector connected to ground. The single shielding at
the free end of the cable must not be connected with earth.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
19
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 19
Cables:
VL3 X27 to Laptop
VL4 X27 to Memory Card System
VL5 24V Power supply to Memory Card System
VL6 X27 to Portable Printer
VL7 24V Power supply to Portable Printer
VL8 X27 to Field Computer System
Communication interface:
COM-SK => Programming interface (Baud rate 19200)
COM-SP => Communication with text display (Baud rate 9600)
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
20
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 20
This supply voltage is the operating voltage for the module outputs. It must
be strong enough to carry the load current of all outputs.
It is provided with a LOAD-DUMP protection to protect (for short times)
wrong polarity and over voltage peaks.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
21
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 21
Binary Outputs A
2A-Short circuit proof
Each single Output of the Output group can withstand a load of 2A, but the
total load must not exceed 10 A. The Output group will be switched OFF if
one of the Output becomes overloaded (> 2 A), the short circuit marker will
be set and the “MK”- LED comes ON.
(A1¿ MK1, A3¿ MK3, A5¿ MK5)
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 22
After the diagnostic bit “Under-voltage UCPU “ DB16.1 has been set, all
access to the EEPROM memory of the CPU plus is blocked
• A drop below 9V results in a reset.
• During and after voltage drops according to DIN 40839 part 2 operates the
CPU plus normally.
14.4.5 Fuse
TR5 / 2.5AT IEC 127-3 Manufacturer Wickmann,
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 23
Signal Status
Voltage level:
„1“ = 24 V* between E (Input) and GND
„0“ = 0 V** between E (Input) and GND
* 13 V up to actual supply voltage
** 0V up to 5 V
The left half of the picture shows so named PULL-DOWN resistors and the
right half PULL-UP resistors. The resistors are installed to get a low ohmical
input. A system with contacts only leads to a (high ohmical) input if dust or
moisture bridges the contacts.
PULL-DOWN resistors are installed with a normal NC contact (means with a
de-energized relay or normal closed switch contact) thus the ECS recognize a
fault after switching ON the system.
PULL-UP resistors are installed with a normal NO contact (means with a de-
energized relay or normal open switch contact) thus the ECS recognize a fault
after switching ON the system.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
24
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 24
Analog Inputs:
„EW 14.1“ for pressure sensor B87A (0 up to 500 bar)
Measuring channel: 0......10 V
Function:
- Voltage supply for the pressure sensor: 24 V
- Output voltages Ua (OUT+, pin 2) of the pressure sensors:
Sensor 0 – 0,4 bar ¿ K= 25 V / bar
Sensor 0 – 60 bar ¿ K= 0,1667 V / bar
Sensor 0 – 500 bar ¿ K= 0,02 V / bar
(Pressure sensors with +1 V Offset)
Ua = (P x K) + 1 V
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
25
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 25
Function:
The temperature transducer convert the
measured values from the PT100 temperature
probe into electrically standardized analog
signals. With the four wire technique the length
and the cross section of the wires are not
important; because the electrical resistance of the
two current lines gets compensated. The sensor
is supplied with a low electrical current from the
temperature transducer (I+ and I-). Additional to
the temperature probe (PT100) resistance the
line resistance influence the current “flow” what
falsified the PT100 measurement. To
compensate the line resistance there are two
additional lines (U+ and U-) close to the PT100
connected. Via this lines the transducer measure
exact a tension drop between in- and output of
the PT100 probe witch is only created by the
PT100 resistance. Because there is no current “flow” through this lines which
are influenced by the line resistance (compared to hydraulic system- it’s like
a test hose with a pressure gauge). The module convert this tension drop into
a current signal (4-20mA) which is proportional to the temperature.
In the interest of proper function must the line resistance not exceed 50 Ω.
Additional the lines must be shielded according to the standards. The picture
shows the wiring of a PT100 probe to a temperature transducer in four wire
technique.
continued
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
26
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 26
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 27
°C -0 -1 -2 -3 -4 -5 -6 -7 -8 -9
-50 80,31 79,91 79,51 79,11 78,72 78,32 77,92 77,52 77,13 76,73
-40 84,27 83,88 83,48 83,08 82,69 82,29 81,89 81,50 81,10 80,70
-30 88,22 87,83 87,43 87,04 86,64 86,25 85,85 85,46 85,06 84,67
-20 92,16 91,77 91,37 90,98 90,59 90,19 89,80 89,40 89,01 88,62
-10 96,09 95,69 95,30 94,91 94,52 94,12 93,73 93,34 92,95 92,55
0 100,00 99,61 99,22 98,83 98,44 98,04 97,65 97,26 96,87 96,48
°C 0 1 2 3 4 5 6 7 8 9
0 100,00 100,39 100,78 101,17 101,56 101,95 102,34 102,73 103,12 103,51
10 103,90 104,29 104,68 105,07 105,46 105,85 106,24 106,63 107,02 107,40
20 107,79 108,18 108,57 108,96 109,35 109,73 110,12 110,51 110,90 111,28
30 111,67 112,06 112,45 112,83 113,22 113,61 113,99 114,38 114,77 115,15
40 115,54 115,93 116,31 116,70 117,08 117,47 117,85 118,24 118,62 119,01
50 119,40 119,78 120,16 120,55 120,93 121,32 121,70 122,09 122,47 122,86
60 123,24 123,62 124,01, 124,39 124,77 125,16 125,54 125,92 126,31 126,69
70 127,07 127,45 127,84 128,22 128,60 128,98 129,37 129,75 130,13 130,51
80 130,89 131,27 131,66 132,04 132,42 132,80 133,18 133,56 133,94 134,32
90 134,70 135,08 135,46 135,84 136,22 136,60 136,98 137,36 137,47 138,12
100 138,50 138,88 139,26 139,64 140,02 140,39 140,77 141,15 141,53 141,91
110 142,29 142,66 143,04 143,42 143,80 144,17 144,55 144,93 145,31 145,68
120 146,06 146,44 146,81 147,19 147,57 147,94 148,32 148,70 149,07 149,45
130 149,82 150,20 150,57 150,95 151,33 151,70 152,08 152,45 152,83 153,20
140 153,58 153,95 154,32 154,70 155,07 155,45 155,82 156,19 156,57 156,94
150 157,31 157,69 158,06 158,43 158,81 159,18 159,55 159,93 160,30 16067
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 28
) • Probably the best aid for trouble shooting is the confidence of knowing
the system and how to use the ECS. Every component has a purpose in
the system. The construction and operating characteristics of each one
should be understood.
• Use always the electric/hydraulic circuit diagram the flowchart and
the operation manual for the specific machine.
1. Select on page 1 of the flow chart, (which contains the table of contents
and the main program) the respective subprogram, for example the
Power-Master lube system.
2. Components in the flow chart, have the same identification code as in the
electric/hydraulic circuit diagram, as shown in cross reference list (page 2-4).
For example: Relay K50 = ?
On page 2 (cross reference list) you find out that relay K50 is shown on
page 43 of the flowchart.
3. On each page of the respective subprogram you will find the functional
description in plain text.
In case of problems concerning reading the program loops, you may find
answers in the frequently asked questions list on page 6 and 7 of the flow
chart.
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
14.0
29
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Electronic Control System Section 14.0
ECS Page 29
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
PC8000-6-D_Sec_14-0_#12046_rev0.doc 16.11.05
Section 15.0
Lubrication System
Page 1
Table of contents
Page
General Function 3
Oscillation Cylinder and Control Block 9
Adjustments 11
One line system 13
Electrical function 17
Capacitive analog sensor for lubricant level monitoring 21
Adjustments
End Line pressure switch 23
Injectors 25
Function Pinion type (dummy wheel) system 27
Electrical Function (dummy wheel) system 31
Capacitive analog sensor for lubricant level monitoring 35
Adjustments
End-Of-Line Switch setting 37
Injectors 39
Components
Hydraulically driven lube pump 41
Injectors 45
End-Line Switch 51
In line Filter 53
Vent valve (Solenoid valve) 55
General Function
continued
Cont'd.
X-axis Time
Y-axis Lubricant supply line pressure
PI Pressure Increasing
S+ Switch point ON of the end of line pressure switch
PH Pressure Holding
S- Switch point OFF of the end of line pressure switch
PR Pressure Relieve
PT Pause Time
Section 15.0
Lubrication System
Page 5
PT-phase
With the pump and controller system in a rest state a pre-set pause time interval
occurs as determined by the PLC.
PI-phase
With energized release valve (7) (*) and solenoid valve (2) the pump continues to
cycle until maximum pressure is achieved and the injectors have metered
lubricant to the bearings.
continued
Cont'd.
X-axis Time
Y-axis Lubricant supply line pressure
PI Pressure Increasing
S+ Switch point ON of the end of line pressure switch
PH Pressure Holding
S- Switch point OFF of the end of line pressure switch
PR Pressure Relieve
PT Pause Time
Section 15.0
Lubrication System
Page 7
Cont'd.
PH-phase
Release valve (7) is still energized to keep the pressure in the lubricant line for a
fix adjusted time (pressure holding time normally 5 min).
PR-phase
In the pressure relieve phase the end of line switch (*) move back to neutral
contact position it signals the PLC that the lube pressure relieve phase is now
active.
PT-phase
The system is now at rest (pause time), ready for another lube cycle and the
sequence repeats itself.
Description:
Oscillation cylinder (6) is auto directional controlled, non pressure related. This
differential cylinder is connected to the pilot pressure suppliy line (P) and a tank
line (T). The speed is contolled by a flow contol valve (3) and the maximum
working pressure is controlled by a pressure reducing valve (2).
Function:
The Oscillatin cylinder (6) starts as soon pilot pressure is send via the connection
(P) to the control block (1). Design related the cylinder (6) retract always first
after start or from any position the piston has stopped before. When the cylinder
reaches the fully retracted position the flow will be redirected automatically and
the cylinders moves in the extending position. If the cylinder comes to an stop in
between the end positions weather the oil supply get stopped or the cylinder is
hold back by a higher work resistance than the supply pressure, the cylinder
changes direction and retracts.
Stroke speed
For a sufficient lube pump operation 18 – 20 double strokes / min for the pump
drive cylinder are required. Therefore the flow reducing valve (3) has to be
adjusted accordingly.
Procedure:
1. Remove electrical plug connection form the discharge valve (7), so no
pressure built up will take place during the following test.
2. Start motor.
3. Switch “ON” the lube system annually and count strokes per minute, visible
on the moving up and down of pipe (1).
If adjustment is required:
a. Loosen lock nut (3.1)
b. Turn adjustment (3) until the right number of strokes is achieved.
turn set screw ccw for more speed and cw to reduce the speed
c. Tighten lock nut (3.1).
Working pressure
The pressure reducing valve (2) mounted in the oscillation control block reduce
the supply pressure internally to maximal allowed 45 bar.
The pressure ration is 6,55 to 1, that means 45 bar supply pressure result in 295 bar
maximum lubricant pressure.
At the end of line pressure switch the pressure should be 180 ±0,5 bar. With the
lubricant line resistance and different lubricant viscosity the pressure at the
lubricant pump output must be higher as 180 bar. For standard condition adjust the
maximum pump pressure to 220 bar –250 bar, depend on lubricant line resistance
and different lubricant viscosity.
Procedure:
1. Disconnect quick coupling (8), so the pump will be blocked when started.
2. Start motor.
3. Switch “ON” the lube system manually, the gauge should show 220-250 bar.
If adjustment is required:
a. Loosen lock nut (2.1)
d. Turn adjustment (2) until the right pressure is shown at the gauge.
turn set screw ccw for lower pressure and cw to increase the pressure
b. Tighten lock nut (2.1).
c. Reconnect quick coupling (8).
Function:
As soon as the adj. "Pause-Time" is finished the solenoid valves
(2) and (7) are energized. The lubricant pump (1) start to pump lubricant in
the lubricant supply line.
By the function of the solenoid valve (7) the port to the vent line (15) (return
line to the lubricant container) is closed, thus a pressure built up is possible.
The high-pressure barrel pump (1) supplies lubricant into the supply line (8). It
continuos through the lubricant filter (12) to the injectors (metering valves) (18).
) • The picture shows an example only. The hole system includes much
more injectors which are connected via pipes or hoses to the supply
line (8).
In the Injectors the lubricant forced with full pump pressure via the feed lines
(19) to the lube points.
The actual operating pressure can be monitored at the pressure gauge (14)
and checked at the pressure check point (17).
continued
Cont'd.
Illustr. Z 21176
When all injectors pistons have reached there final position no more lubricant
is accepted from the supply line which causes a pressure increase in the
supply line (8).
As soon as the pressure reaches the adjusted value of the end-of-line switch
(16) the solenoid valves (2) de-energized and the lubricant pump switched
Off. Depend on different factory settings vent valve (7) de energize together
with solenoid valve (2) or after a fix adjusted time of max. 5 minutes.
With de-energized solenoid valve (7) the port to vent line (15) ( return line to
the lubricant container ) opened and release the lubricant and lubricant
pressure in to the container.
With the diminishing pressure in the main line the pistons of the injector (18)
are forced by spring force in their initial position and the discharge chambers
are filled with grease for the following lubrication cycle.
The system is now prepared for a new lubrication cycle. The operation is re-
initiated after the next "Pause Time" is elapsed.
The proper build-up of the pressure in the supply line (8) is monitored by the
end-of-line switch (16).
If the pressure adjusted at the end-of-line switch will not reached within the
adjusted "Monitoring Time" the fault message ”Central lubrication system
fault” comes up on the text display and the system switch off
W
• Grease qualities to be used:
According to NLGI classes 000, 00, 0 and 1 according to the lowest
ambient temperature in the operation area
continued
Cont'd:
Illustr. Z 21177a
The next lubrication cycle starts after the decreasing time and pause time has
expired.
With the switch S24 an additional lubrication can be carried out any time provided
the end of line pressure switch (B43) contact is closed.
Monitoring:
The orderly built-up of the pressure in the lubricant supply line is monitored by
the end-of-line switch (B43 or B46).
If the pressure adjusted at the end-of-line switch is not reached within the adjusted
maximal increasing time the PLC switch off both solenoid (Y7 and Y7A or Y9
and Y9A) valves and send the fault message ”Central lubrication system fault” or
“Swing ring lubrication system fault” to the text display at the dash board.
If the excavator is still working additional four hours with faulty lubrication
system the PLC stop the bucket function. This function is to prevent trouble
depend on a lack of lubricant.
Continued
Task:
A lubricant (L) maximum filling level monitoring is necessary to prevent an
overfilling of the grease barrel (C) via the refilling system (only systems with
refilling arm). The PLC use the analog level signal from the sensor to activate a
lamp at the refilling arm just in the moment when the lubricant container is full.
The sensor (S) is mounted on top of the lubricant container and reaches into the
lubricant.
The refilling level activate only a message at the text display to inform that the
lubricant level must be filled up. The message comes up if the lubricant level
reach 5% (910 mm from the cover plate).
The minimum level stop the respective lubrication pump and release the
lubricant pressure until the lubricant level reach the 0% mark (950 mm from the
cover plate). It is necessary to stop the lubrication system with empty lubricant
container to prevent the lubrication pump from running dry. With empty
lubricant container the bucket motion will be switched off after four hours.
Function:
The capacitively level sensor (S) check continuous the lubricant level (L) and
convert the capacitive signal into a current signal between 4 and 20mA. The
current signal increase with increasing lubricant level.
Use the specific electric circuit diagram and program flow charts.
Adjustments
2. Start motor.
3. Start a lube cycle with the dashboard switch S24.
+
4. Watch pressure gauge. At a pressure of 180 10 bar the end-line switch
must react and the lubricants pump must stop.*
* If at the same time the pressure shown at the built-in gauge is noted
down, this pressure can be taken for later on checks as a reference
pressure.
If re-setting is required:
5. Screw out screw 1 and take off cover 2.
6. Alter the spring tension with adjustment screw 3 that the switch
operates at 180 bar.
7. Install cover 2 and screw 1.
continued
Cont'd:
Injectors, illustr. 21181:
) • The max. lubricant output is adjusted if the indicator stem (B) moves
not more further outwards
Legend: Z 21183a
(1) Lubricant pump drive (Hydraulic cylinder)
(2) Solenoid valve Y9 (Oil pressure supply)
(3) Flow control valve
(4) Pressure reducing valve
(5) Hydraulic oil supply line (Pilot pressure)
(6) Hydraulic oil return line
(7) Vent valve Y9A (Solenoid valve, de-energized open)
(8) Grease supply line to injectors
(9) Lubricant level indication
(10) Lubricant barrel
(11) Pump mechanism
(12) Lubricant filter
(13) Hydraulic pressure test plug (Operating pressure)
(14) Lubricant pressure gauge (Operating pressure)
(15) Vent line to barrel
(16) Breather
(17) Electrical terminal box
Principle of operation:
By the lubricant pump, the lubricant is supplied to the centered bore hole (B) of the
lubrication type pinion (R). Bore hole (B) must be perfectly aligned to the center of
the lubrication type pinion (A) to be greased, so that lubricant leaves the tooth flank
always when the gear tooth is in contact. The grease outlet (D) of the lubricating type
pinion is arranged at a different angle for each tooth, so that the lubricant is distributed
in a uniform and perfect manners on the tooth flank of the drive pinion to be
lubricated.
Function:
As soon as the adjusted "Pause-Time" elapse the solenoid valves (2 + 7). energized
and the lubricant pump (1) start to pump lubricant.
By the function of the solenoid valve (8) the port to the vent line (15) (return line to
the lubricant container) closed, thus a pressure built up is possible.
The high-pressure lubricant pump (1) supplies lubricant into the supply line (8). It
continuos through the lubricant filter (12) to the injectors (metering valves) (18).
• The picture shows an example with one pinion only. There are also
machines which have more lubrication type pinion (dummy wheel).
By the injectors the lubricant is forced with full pump pressure via the feed line
(19) to the centered bore hole (B) of the lubricating type pinion (R).
continued
Cont'd.
Illustr. Z 21183a
The actual operating pressure can be monitored at the pressure gauge (14)
and checked at the pressure check point (17). When all injector pistons have
reached there final position no more lubricant will accepted from the supply
line (8) which causes a pressure increase in the supply line.
Depend on different factory settings vent valve (7) de energize together with
solenoid valve (2) or after a fix adjusted time of max. 5 minutes.
With de-energized solenoid valve (7) the port to vent line (15) ( return line to
the lubricant container ) opened and release the lubricant and lubricant
pressure in to the container.
With the diminishing pressure in the main line the pistons of the injector (18)
are forced by spring force in their initial position and the discharge chambers
fill up with grease for the following lubrication cycle.
The system is prepared for the next lubrication cycle. The operation is
reinitiated after the next "Pause Time".
The proper build-up of the pressure in the supply line (8) is monitored by the
end-of-line switch (16).
If the pressure adjusted at the end-of-line switch is not reached within the
adjusted "Monitoring Time" the fault message ”Slew ring gear lubrication
system fault” is shown on the text display and the pump switch off.
continued
Cont'd:
Illustr. Z 21177b
The next lubrication cycle starts after the decreasing time and pause time has
expired.
With the switch S26 an additional lubrication can be carried out any time provided
the end of line pressure switch (B46) contact is closed.
Monitoring:
The orderly built-up of the pressure in the lubricant supply line is monitored by
the end-of-line switch (B46).
If the pressure adjusted at the end-of-line switch is not reached within the adjusted
maximal increasing time the PLC switch off both solenoid valves (Y9 and Y9A)
and send the fault message ”Central lubrication system fault” to the text display at
the dash board.
If the excavator was working additional four hours with faulty lubrication system
the PLC stop the bucket function. This function is to prevent trouble depend on a
lack of lubricant.
Continued
Task:
A lubricant (L) maximum filling level monitoring is necessary to prevent an
overfilling of the grease barrel (C) via the refilling system (only systems with
refilling arm). The PLC use the analog level signal from the sensor to activate a
lamp at the refilling arm just in the moment when the lubricant container is full.
The sensor (S) is mounted on top of the lubricant container and reaches into the
lubricant.
The refilling level activate only a message at the text display to inform that the
lubricant level must be filled up. The message comes up if the lubricant level
reach 5% (910 mm from the cover plate).
The minimum level stop the respective lubrication pump and release the
lubricant pressure until the lubricant level reach the 0% mark (950 mm from the
cover plate). It is necessary to stop the lubrication system with empty lubricant
container to prevent the lubrication pump from running dry. With empty
lubricant container the bucket motion will be switched off after four hours.
Function:
The capacitively level sensor (S) check continuous the lubricant level (L) and
convert the capacitive signal into a current signal between 4 and 20mA. The
current signal increase with increasing lubricant level.
Use the specific electric circuit diagram and program flow charts.
Adjustments
1. Connect pressure gauge to check point close to the end of line pressure
switch.
2. Block the swing function with the swing ring parking, use the switch at
the dash board.
3. Start motor.
4. Start a lube cycle with the dashboard switch S26 and activate for a short
time the swing function to the left or right.
+
5. Watch pressure gauge. At a pressure of 180 10 bar the end of line
switch must react and the lubricants pump must be stopped.*
* If at the same time the pressure shown at the built-in gauge is noted
down, this pressure can be taken for later on checks as a reference
pressure.
But be careful this pressure is higher than the pressure shown at the test
gauge because of the long distance between pump and end of the
supply line.
)
• 180 bar is the normal setting.
Under particular circumstances it may be necessary to increase the
pressure slightly
If re-setting is required:
continued
Cont'd:
Injectors, illustr. 21181:
) • The max. lubricant output is adjusted if the indicator stem (B) moves
not more further outwards
HINT:
Loss of pressure or to short pump strokes indicates:
continued
PROBLEMS:
TASK:
A readjusted (at the injector) volume of grease is pushed with the injectors to
the bearings or to the progressive distributors.
continued
Cont'd:
Pos. 1 The injector piston (2) is in its normal or rest position. The discharge
chamber (9) is filled with lubricant from the previous cycle.
Under the pressure of incoming lubricant the slide valve (4) is about
to open the passage (5) leading to the piston.
Pos. 2 When the slide valve (4) uncovers the passage lubricant is admitted to
the top of piston (2) forcing the piston down. The piston force
lubricant from the discharge chamber (9) through the outlet port (10)
to the bearing or progressive distributor.
The lubricant pressure at the bearing or the progressive distributor is
always the same as the pump pressure.
Pos. 3 As the piston completes its stroke, it pushes the slide valve (4) past the
passage, cutting off further admission of lubricant to the passage.
Piston and slide valve remain in this position until lubricant pressure
in the supply line is vented (relieved) at the pump.
This is indicated by the injector stem (8). (fully in)
Pos. 4 After pressure is relieved the compressed spring (3) moves the slide
valve (4) to closed position.
This opens the port from the measuring chamber and permits the
lubricant to be transferred from the top of the piston to the discharge
chamber.
This is also indicated by the injector stem (8) (fully out)
continued
Cont'd:
The injectors are designed so that the lubricant out- put of two or more
injectors can be combined without the use of tees.
The injector body (1) has two outlets ports (a + b), one above the other.
The connector tube (2) is used to couple the injectors together.
Lubricant from injector No. 1 is directed through the connector tube into the
discharge chamber of injector No. 2 but simply combines with the lubricant
delivery of injector No. 2 to yield double output from the out- let of injector
No. 2.
This does not interfere with the operation of injector No. 2.
End-line switch
TASK:
The pressure control unit is monitoring and controlling the centralized lube
system.
Function:
One pressure control unit is installed in each greasing circuit. The grease
pressure, produced by the pneumatic barrel pump, is with his force also at the
piston (1)
If the grease pressure reaches the tension of the spring (4), the piston (1) is
forced against the disk (2), thus that the contacts of the switch (5) are
operated and a electric impulse is given to the electronic control unit of the
greasing equipment.
Adjusting has to be done with the sleeve (6). Clockwise - higher switch point,
counterclockwise - lower switch point.
In-line filter
• Before servicing stop the motor and remove ignition key in order to
prevent operation of the system.
) • A clogged filter element will be moved against the spring force by the
lubricant pressure and unfiltered lubricant reaches the system!
TASK:
By the function of the vent valve the lubricant supply line gets pressure-
relieved, after the lubrication cycle is finished. The injector pistons can move
into their initial position.
Function:
The solenoid gets energized. When the lubrication starts.
The connection from A to B gets closed, thus a pressure build-up is possible.
The solenoid gets de-energized, as soon as the lubrication cycle is finished.
This causes opening of the connection A to B, thus the supply line to the
lubricant barrel is open. The lubricant flows from A to B or vice versa
along the main valve cone (5).