Manual of SDP-10KW Inverter
Manual of SDP-10KW Inverter
Manual of SDP-10KW Inverter
cc
★ Please read this user manual carefully before use, any wrong operation will do
User Manual
1
Solar Sine Wave Inverter www.lgis.cc
CONTENTS
2. Product outline…………………………………………………..………………5
7. Schematic Diagram………………………………………………….………..14
2
Solar Sine Wave Inverter www.lgis.cc
1. Safety Instruction
ion to the following items to avoid adverse effects suffered in the store:
No corrosive liquid, oil mist, splashing water, salt fog, rain, humidity;
If don’t use the machine for a long time, it should be power on every six months;
1.3 Transport
During the process of handling the product, should avoid strong vibration and bump. It’s
strictly prohibited packing upside down, when open the carton and carry the product out,
please don’t missing accessories, instruction manual and warranty card when moving
out of the box. In addition, this product is big volume and heavy, please pay attention to
3
Solar Sine Wave Inverter www.lgis.cc
1.4 Notice
This user manual allows you to easily operate and maintain the system, be sure to take
good care of it. Before use this product, please read these instructions carefully.
1, Before use carefully read and understand the full content of manual instruction.
6, The Machine must be installed in a horizontal ground. The cable must be connected
7, Please do not put the machine near heating, warmer, air-conditioner or exhaust pipe.
8, Please do not overload to use this machine in order to avoid overload failure.
9, In order to avoid electric shock, please do not disassemble the machine. When you
need to maintain, please find and seek support from the professionals.
10, The machine will have heating, which is the normal condition. But it should keep
good ventilation and clean and tidy in the installation place.
11, Please keep the manual instruction well for the future reference.
4
Solar Sine Wave Inverter www.lgis.cc
2. Product outside view
Product size and shape varies from different power model, it's subject to the actual size confirmation.
5
Solar Sine Wave Inverter www.lgis.cc
3. Product Introduction
Characteristic:
◆ Two types of start mode: Step-down Voltage Start and Variable Frequency Start.
Customers can set start mode according to the nature of their load. If the inverter take
inductive load, especially for taking motor, the instantaneous start current of motor is very
big, then inverter’s power need enlarge many times. However our this new inverter don’t
need enlarge too many power, you could set Variable Frequency Start to take your inductive
load easily. This function is very convenient for users and also reduce frequency
converter’s usage, which reduced the cost of equipment investment, also easy to connect
wires and control.
◆ The output frequency can be set. For example, if you want to control the motor speed
30Hz, you could set the frequency 30Hz and the inverter output will be 30Hz. Because it
belongs to low frequency inverter, we suggest choose the output frequency over 30Hz to
avoid transformer overheating. This function is also convenient for customer, you can
change the frequency setting on the LCD screen.
◆ The output voltage can be set between -40 % to +20 % of rated voltage. For example,
the output rated phase voltage(L to N) is 220V, you can set the output voltage between
80-264V. And the accuracy of output voltage is very high, usually no more than 1%.
◆ The DC input voltage range can also be set. Over-voltage point, under-voltage point,
over-voltage recovery point and under-voltage recovery point can be set via the LCD panel.
Convenient for increasing or reducing the quantity of batteries, photovoltaic modules also
can be used flexibly. Not need worry about adding new photovoltaic modules or change
battery voltage in solar power system, change these parameters settings on LCD then all is
ok. It reduced the cost of investment again. If the customer want to change these
parameters, please try to communicate with our engineers, we will provide you professional
service for free.
◆ Powerful data display and fault instruction function. The LCD can display DC input
voltage, output frequency, phase voltage, phase current, AC bypass input voltage,
Generated amount KWH, time and date, temperature, fault code display.
◆ Pure sine wave output with good transient response less than 50ms, waveform
distortion is very little, higher conversion efficiency and stable output voltage.
6
Solar Sine Wave Inverter www.lgis.cc
◆ Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, with
high efficiency and stable performance. It also with powerful protection function, the
protection for short circuit, over load, over temperature is more safe and reliable. It’s service
life can up to 15 years or more.
◆ Wide input voltage can be set according to customer’s requirement. Input voltage range
can be selected from 100-500V or 200-850V.
◆ Output AC Power suitable for all types of home electric equipment, electronics load,
electric tools and electric motors etc.
◆ With Low Frequency Transformer, which ensures high efficiency and low no-load loss.
◆ European CE (EMC & LVD) certificated and Australia CEC & ERAC approved.
7
Solar Sine Wave Inverter www.lgis.cc
4. Main Parameters
Model SDP-10KW
Display LCD
Input reverse protection, under-voltage and
Inverter over-voltage, output overload, short-circuit,
Protection overheat protection
function No automatic recovery, need to restart the
Short circuit protection
machine
Cooling method Fan-cooling
Ambient temperature -10℃~+50℃
Using environment humidity 0~90%, No condensation
Working
Noise (1 meter) <50dB
environment
Degree of protection IP20(indoor)
Using altitude(m) ≤2000
Mechanical Vertical type(D x W x H) 540x540x760mm
dimension Weight 95Kg
8
Solar Sine Wave Inverter www.lgis.cc
5. LCD display explanation
5.1, LCD display description
Indicator description:
E. Manual: Variable frequency mode, the inverter work with variable frequency mode running
9
Solar Sine Wave Inverter www.lgis.cc
This error only for 3 phase output, single phase output without this error display
Fault alarm can be divided into automatic recovery and non-automatic recovery: When the LCD
screen display MOD error and overload, need to manually recovery, turn off the DC circuit breaker
until the LCD screen is completely extinguished and then turn on the DC circuit breaker;
over-voltage, under-voltage can automatic recovery (the under-voltage recovery default setting is 10
Keypad function
1. Running Info Running state display
10
Solar Sine Wave Inverter www.lgis.cc
Press “ 2. Inv Start Mode ” display as following
Y : YES N: NO
11
Solar Sine Wave Inverter www.lgis.cc
The following settings only for professionals operation, the non-professionals
can’t change parameters, otherwise, you will undertake all damages caused by
privately settings.
Noticed: Output voltage and current value setting not more than
12
Solar Sine Wave Inverter www.lgis.cc
Press “ 3. CT&Temp Set ” Current and mutual inductance ratio and
Protection temperature setting display as following
Min Minute
13
Solar Sine Wave Inverter www.lgis.cc
Press “ 7. Time Set ” to display as following
Time:
7. Schematic Diagram
AC Output curve
14
Solar Sine Wave Inverter www.lgis.cc
AC Output curve
1.2 DC input cable must be through from the DC input terminals, correctly connect to the positive and
1.3 Absolutely prohibit DC input power supply connect to the inverter output terminal.
1.4 The connection cable between the battery and inverter should be as short as possible, otherwise the
harmonic leakage current from cables will be harmful to inverter and the system equipment.
1.5 System grounding terminal must be grounded, and make the ground wire’s length as short as
possible. Do not allow welding machine, motor and other high current device in this system common
ground. Ensure all system’s ground wires are separately layout from high current electrical equipment.
15
Solar Sine Wave Inverter www.lgis.cc
1, Please don’t turn off the DC Input Breaker often, otherwise it will cause will
cause DC input breaker damaged. If you want to shut down the inverter, just need tu
rn off the AC output breaker and Start button.
2, If you have to turn off the DC input breaker, please turn off the AC Output Breaker
and Start button to make inverter stop working, then turn off the DC Input breaker.
2.2 After inverter start-up normally under no-load conditions, then connect with the load. Load should be
added one by one to avoid excessive inrush current of adding all loads at same time to cause inverter
overload protection.
2.3 During operation, if the LCD panel display default light on, the device will automatically alarm
protection, no AC output, the indicator for 30 seconds, then you should turn off the start switch. After
identified default reasons, you could start inverter under no-load to test.
3.2 correctly connect with input wires, be careful of the positive and negative pole of input wires, which
3.4 Recommend to turn on the DC input circuit breaker firstly, then turn on AC output breaker
16
Solar Sine Wave Inverter www.lgis.cc
Please see the following, which is the wiring terminals:
1.2 Turn on the DC input breaker, if the breaker happen to the trip at the first time, it’s a normal
1.3 Please don’t turn off DC input breaker under the inverter with load, otherwise it will cause DC input
breaker damaged.
1.4 When the machine happen MOD, overload, output error and fault alarm, turn off the DC input
1.5 Put the inverter on ventilated and away from sunlight, confirmed the machine and wall distance
1.6 Don’t block the vents, if found the vents blocked, please clean up in time.
1.7 When the inverter is running normally and temperature is rising. If the fan stop working,
please replace the fan in time. (The starting temperature of the fan is 45°C).
1.8 Recommend to turn on the output circuit breaker firstly, then turn on start switch. Make the inverter
starting load, can effectively avoid the damage of large inrush current to the machine.
1.9 Don’t connect ground wire (GND) of cabinet and neutral wire (N) together.
17
Solar Sine Wave Inverter www.lgis.cc
2), Notice:
2.1 All operations of equipment must be done by professionals, please remove metal jewelry on hands
2.2 The inside cooling fan of the machine is controlled by temperature, it’s a normal phenomenon that
the fan is not running when inverter just start soon or taking little load, the fan only will run when cabinet
2.3 When the machine is working, in case of accidents and to avoid electric shock, please don’t open the
cover of cabinet.
2.4 Please don’t make change to the circuit line privately when regular checking, in case of damage.
2.5 It’s a normal phenomenon that the inverter has a certain degree of fever during the use process, but
should keep the environment of installation ventilated, cooling and clean, especially can’t block air
ventilator.
2.6 The inside all CMOS components of the machine can’t touch, when the circuit is powered on don’t
2.7 After connect all wires, please must be carefully check (voltage value, positive and negative pole are
2.8 Even if the all switch on the panel is OFF, but inverter’s part of capacitor still electric, please don't
touch.
2.9 When take with motor and pump or other inductive loads, the inverter had best leave 30% of the
power margin, should be considered the impact current to the machine, to ensure reliable power supply
to inverter
Before opening the cover of cabinet maintenance, should completely cut off the power and shut down
inverter 10 minutes or longer, after capacitors end discharging, then can proceed maintenance ( the
machine inside has many capacitors and discharge need some time), be careful not to damage any
18
Solar Sine Wave Inverter www.lgis.cc
4), Troubleshooting
Output overload or short Close the load, check whether there has
circuit breakage or short circuit of load cable
19
Solar Sine Wave Inverter www.lgis.cc
10. After-Sales Service
Sales staff cooperate with Engineering department, delivery the products that meet the
needs of users and be in good condition to the user. Terms are stipulated as following:
We usually adopt entrust transport way to delivered the goods, when the user sign for the
goods by delegating transport, should carefully check whether the structure and
appearance of product is damaged, if with doubt, the user shall not sign for it, if you sign for
it then means you agree the goods without any fault or damage during transportation.
1. Our company seriously promised: For all sold out inverter, we provide one year warranty
from the date of delivery and supply maintenance services all the time.
2. Within warranty time, when inverter meets all the installation environment and using
conditions, also operation correctly, if the inverter have damage or accident happens,
please inform our company after-sales service department, when contact us, please
provide the equipment model, serial number and complete problem explanation. We will
provide free components for replacement firstly, if the problems still can't be solved, please
contact the manufacturer as soon as possible, prohibit remove the parts by yourself !
However, any of the following situation happened, are not included in the warranty:
3.1 Damage caused by any modification or repair privately and without company's
permission.
3.3 Damage caused by supply power not according to the electrical specification or the bad
environment.
3.4 Damage caused by not following user manual’s security items and using instruction
3.5 Damage caused by without the permission of the company maintenance person,
20