Manual of SDP-10KW Inverter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Solar Sine Wave Inverter www.lgis.

cc
★ Please read this user manual carefully before use, any wrong operation will do

damage to this machine.

Solar Sine Wave Inverter

User Manual

Yueqing Sandi Electric Co., Ltd

1
Solar Sine Wave Inverter www.lgis.cc

CONTENTS

1. Safety Instruction ……………………………………………………………..…3

2. Product outline…………………………………………………..………………5

3. Product introduction ……………………………………………………………6

4 Technical data …………………………………………………..……………… 8

5. Display explanation …………………………………………………………… 9

6. LCD parameter description…………………………………………………… 9

7. Schematic Diagram………………………………………………….………..14

8. Installation and operation……………………………………………………..15

9. Maintenance and Notice ………………………………..……………………16

10. After sales service…………………..…………………………………………19

2
Solar Sine Wave Inverter www.lgis.cc

1. Safety Instruction

1.1 Open box


Sandi SDP series inverters have been tested strictly before leaving our factory, however
they may be damaged during the transportation, please check them carefully if the
products received are completed and if the following items: model、power、DC input
voltage、AC output voltage and Frequency (Hz) are consistent with the order. If any
damages or discrepancy found, please contact transportation company or us
immediately. Meanwhile, please provide the damaged pictures to help us solve the
problem for you asap.

1.2 Storage environment


In order to ensure good performance and long service life, the product should pay attent

ion to the following items to avoid adverse effects suffered in the store:

 Away from direct sunlight (avoid for outdoor);

 No corrosive liquid, oil mist, splashing water, salt fog, rain, humidity;

 placed no dust and dry air and ventilated place

 no combustible and explosive goods;

 Environment temperature: -10 ℃ ~ 50 ℃;

 If don’t use the machine for a long time, it should be power on every six months;

1.3 Transport
During the process of handling the product, should avoid strong vibration and bump. It’s

strictly prohibited packing upside down, when open the carton and carry the product out,

please don’t missing accessories, instruction manual and warranty card when moving

out of the box. In addition, this product is big volume and heavy, please pay attention to

safety to avoid hurt your body when handling.

3
Solar Sine Wave Inverter www.lgis.cc
1.4 Notice
This user manual allows you to easily operate and maintain the system, be sure to take

good care of it. Before use this product, please read these instructions carefully.

1, Before use carefully read and understand the full content of manual instruction.

2, Be careful when moving the machine, avoid the dropping impact.

2, To avoid injuring personal safety, the installation must be grounded.

6, The Machine must be installed in a horizontal ground. The cable must be connected

strengthened, to prevent the damaged of mouse.

7, Please do not put the machine near heating, warmer, air-conditioner or exhaust pipe.

8, Please do not overload to use this machine in order to avoid overload failure.

9, In order to avoid electric shock, please do not disassemble the machine. When you

need to maintain, please find and seek support from the professionals.
10, The machine will have heating, which is the normal condition. But it should keep
good ventilation and clean and tidy in the installation place.
11, Please keep the manual instruction well for the future reference.

4
Solar Sine Wave Inverter www.lgis.cc
2. Product outside view

Front view Side view Back view

 Product size and shape varies from different power model, it's subject to the actual size confirmation.

5
Solar Sine Wave Inverter www.lgis.cc
3. Product Introduction
Characteristic:
◆ Two types of start mode: Step-down Voltage Start and Variable Frequency Start.
Customers can set start mode according to the nature of their load. If the inverter take
inductive load, especially for taking motor, the instantaneous start current of motor is very
big, then inverter’s power need enlarge many times. However our this new inverter don’t
need enlarge too many power, you could set Variable Frequency Start to take your inductive
load easily. This function is very convenient for users and also reduce frequency
converter’s usage, which reduced the cost of equipment investment, also easy to connect
wires and control.
◆ The output frequency can be set. For example, if you want to control the motor speed
30Hz, you could set the frequency 30Hz and the inverter output will be 30Hz. Because it
belongs to low frequency inverter, we suggest choose the output frequency over 30Hz to
avoid transformer overheating. This function is also convenient for customer, you can
change the frequency setting on the LCD screen.
◆ The output voltage can be set between -40 % to +20 % of rated voltage. For example,
the output rated phase voltage(L to N) is 220V, you can set the output voltage between
80-264V. And the accuracy of output voltage is very high, usually no more than 1%.
◆ The DC input voltage range can also be set. Over-voltage point, under-voltage point,
over-voltage recovery point and under-voltage recovery point can be set via the LCD panel.
Convenient for increasing or reducing the quantity of batteries, photovoltaic modules also
can be used flexibly. Not need worry about adding new photovoltaic modules or change
battery voltage in solar power system, change these parameters settings on LCD then all is
ok. It reduced the cost of investment again. If the customer want to change these
parameters, please try to communicate with our engineers, we will provide you professional
service for free.
◆ Powerful data display and fault instruction function. The LCD can display DC input
voltage, output frequency, phase voltage, phase current, AC bypass input voltage,
Generated amount KWH, time and date, temperature, fault code display.
◆ Pure sine wave output with good transient response less than 50ms, waveform
distortion is very little, higher conversion efficiency and stable output voltage.

6
Solar Sine Wave Inverter www.lgis.cc
◆ Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, with
high efficiency and stable performance. It also with powerful protection function, the
protection for short circuit, over load, over temperature is more safe and reliable. It’s service
life can up to 15 years or more.
◆ Wide input voltage can be set according to customer’s requirement. Input voltage range
can be selected from 100-500V or 200-850V.
◆ Output AC Power suitable for all types of home electric equipment, electronics load,
electric tools and electric motors etc.
◆ With Low Frequency Transformer, which ensures high efficiency and low no-load loss.
◆ European CE (EMC & LVD) certificated and Australia CEC & ERAC approved.

7
Solar Sine Wave Inverter www.lgis.cc
4. Main Parameters
Model SDP-10KW

Isolation Low frequency transformer

Input rated voltage (VDC) 160V

DC Input Input rated current (A) 62.5A

Input DC voltage range (VDC) 140~230V

Rated AC output power 10KW

Phases Single phase, 2 wire

Output rated current (A) 42A

Power Factor(PF) 0.95

Output voltage (V) 240VAC±2%

Output frequency accuracy (Hz) 50Hz ± 0.05%


AC Output
The dynamic response 4% (Load 0←→100%)

Overload 125% 1min 、150% 10s

Inverter efficiency >94%


≤2% (Linear load) ≤3% (The nonlinear
Waveform distortion rate
loads)
Running mode Working continuously

Display LCD
Input reverse protection, under-voltage and
Inverter over-voltage, output overload, short-circuit,
Protection overheat protection
function No automatic recovery, need to restart the
Short circuit protection
machine
Cooling method Fan-cooling
Ambient temperature -10℃~+50℃
Using environment humidity 0~90%, No condensation
Working
Noise (1 meter) <50dB
environment
Degree of protection IP20(indoor)
Using altitude(m) ≤2000
Mechanical Vertical type(D x W x H) 540x540x760mm
dimension Weight 95Kg

8
Solar Sine Wave Inverter www.lgis.cc
5. LCD display explanation
5.1, LCD display description

5.2 Indicator of LED light function


There has 5 LED light in the panel: Grid, Run, Fault, Auto, Manual.

Indicator description:

A. Grid: AC bypass priority mode, it indicates the AC grid input condition.

B. Run: Battery priority mode, it indicates the battery supply condition.

C. Fault: System fault.

D. Auto: Inversion running, it indicates the inverter work normally.

E. Manual: Variable frequency mode, the inverter work with variable frequency mode running

6. LCD parameter description


Inverter power on, the first interface display parameter, press “down” key to display
as following 4 item
DC IN DC input voltage display

AC OUT AC output voltage display

AC OUT Output current display

Freq Output frequency display

9
Solar Sine Wave Inverter www.lgis.cc

AC INPUT: AC bypass input

U: V Bypass phase voltage

OUT: Total generated amounts


W: KWH Generated amounts

Inv State: Inverter working state:

DCU OVER DC over-voltage

DCU UNDER DC under-voltage

OVER LOAD Over-load

MOD Module error

Fault display:”N” indicate no error and ”Y” indicate with error

OUTErr Output voltage unbalance

 This error only for 3 phase output, single phase output without this error display

 Fault alarm can be divided into automatic recovery and non-automatic recovery: When the LCD

screen display MOD error and overload, need to manually recovery, turn off the DC circuit breaker

until the LCD screen is completely extinguished and then turn on the DC circuit breaker;

over-voltage, under-voltage can automatic recovery (the under-voltage recovery default setting is 10

minutes), can set according to the customer needs.

Keypad function
1. Running Info Running state display

2. Inv Start Mode Inverter Start mode

3. Work Modes Working Mode

4. Parameter Set System parameter setting

10
Solar Sine Wave Inverter www.lgis.cc
Press “ 2. Inv Start Mode ” display as following

1. Voltage Constant frequency step-down voltage


Starting mode
2. Frequency Variable frequency starting mode
Y : YES N: NO

Press “ 3. Work Modes ” display as following

1. Inv Battery priority mode


2. Bypass AC bypass priority mode

Y : YES N: NO

Time: Display current time and date

Tem: Environmental temperature display

Press “ 4. Parameter Set ” need to enter password.


 If you want to adjust the parameter setting, please contact the
manufacturer ask for password

 When inverter is working, please don't adjust parameters setting.


If you want to adjust parameter setting, please turn off start button, t
hen operation.

11
Solar Sine Wave Inverter www.lgis.cc
 The following settings only for professionals operation, the non-professionals
can’t change parameters, otherwise, you will undertake all damages caused by
privately settings.

1. Freq Set Frequency setting


2. VIout Set Output voltage setting
3. CT&Temp Set Current ratio setting and temperature
Protection setting
4. Alarm Set DC over-voltage and under-voltage setting

5. UdcR Set Recovery setting of DC over-voltage


and under-voltage
6. UdcUnder Delay Default recovery time of under-voltage
is 10 minutes
7. Time Set Date and time setting
8. Overload Set Overload times and overload time setting

Press “ 1. Freq Set ” output frequency setting display as following

Max Fre: HZ Recommend maximum output

frequency setting between 30-100Hz

Min Fre: HZ The minimum frequency of output Starting

can’t less than 5Hz

Press “ 2. Vout Set ” output voltage and current setting display as


following
Vout Set Output voltage setting

Iout –Max Set: Output current setting

Noticed: Output voltage and current value setting not more than

20% of the rated power, if the transformer damaged caused by

wrong settings will out of the warranty

12
Solar Sine Wave Inverter www.lgis.cc
Press “ 3. CT&Temp Set ” Current and mutual inductance ratio and
Protection temperature setting display as following

CT Set: Current and mutual inductance ratio setting

Temp Set: Protection temperature setting

Press “ 4. Alarm Set ” over-voltage and under-voltage setting display as


following

Udc-over Set: DC over-voltage protection setting

Udc-under Set: DC under-voltage protection setting

Press “ 5. UdcR Set ” DC over-voltage and under-voltage recovery


setting display as following

Udc-over Set: DC over-voltage recovery setting

Udc-under Set: DC under-voltage recovery setting

Press “ 6. Udc Under Delay ” Under-voltage recovery time setting display


as following

Udc Under Delay: Under-voltage recovery time setting

Min Minute

13
Solar Sine Wave Inverter www.lgis.cc
Press “ 7. Time Set ” to display as following

Time:

Display date and time setting

Press “ 8. Over Load Set ”

Rover Load Set: Overload times setting

Over load Time Set: Overload time setting

7. Schematic Diagram

AC Output curve

14
Solar Sine Wave Inverter www.lgis.cc
AC Output curve

8. Installation and Running Status


8.1, When wiring should attention to the following:
1.1 Check the front panel breakers are in "OFF" state, check whether there is a short circuit on load.

1.2 DC input cable must be through from the DC input terminals, correctly connect to the positive and

negative pole of the machine, attention can’t be reversed.

1.3 Absolutely prohibit DC input power supply connect to the inverter output terminal.

1.4 The connection cable between the battery and inverter should be as short as possible, otherwise the

harmonic leakage current from cables will be harmful to inverter and the system equipment.

1.5 System grounding terminal must be grounded, and make the ground wire’s length as short as

possible. Do not allow welding machine, motor and other high current device in this system common

ground. Ensure all system’s ground wires are separately layout from high current electrical equipment.

15
Solar Sine Wave Inverter www.lgis.cc

1, Please don’t turn off the DC Input Breaker often, otherwise it will cause will
cause DC input breaker damaged. If you want to shut down the inverter, just need tu
rn off the AC output breaker and Start button.
2, If you have to turn off the DC input breaker, please turn off the AC Output Breaker
and Start button to make inverter stop working, then turn off the DC Input breaker.

2, Power on and running status:


2.1 The power of load that inverter will take can’t exceed the rated power of inverter, otherwise it will

shorten the service life of equipment or cause the device trouble.

2.2 After inverter start-up normally under no-load conditions, then connect with the load. Load should be

added one by one to avoid excessive inrush current of adding all loads at same time to cause inverter

overload protection.

2.3 During operation, if the LCD panel display default light on, the device will automatically alarm

protection, no AC output, the indicator for 30 seconds, then you should turn off the start switch. After

identified default reasons, you could start inverter under no-load to test.

3, Connect with wires and operation procedure


3.1 Confirm the machine is in OFF condition.

3.2 correctly connect with input wires, be careful of the positive and negative pole of input wires, which

cannot reverse connection.

3.3 Correctly connect with output wires.

3.4 Recommend to turn on the DC input circuit breaker firstly, then turn on AC output breaker

then start switch.

16
Solar Sine Wave Inverter www.lgis.cc
Please see the following, which is the wiring terminals:

Remarks: DC Input: positive pole (+), negative pole (-)


AC Output: L and N wires

Attention: Ground wire is connected to the earth, can't connect

ground wire (GND) of cabinet and neutral wire (N) together.

9. Maintenance and Notice


1), Caution for use
1.1 Be careful of the positive pole and negative pole of battery input, which can’t reverse.

1.2 Turn on the DC input breaker, if the breaker happen to the trip at the first time, it’s a normal

phenomenon, because the capacitor is charging.

1.3 Please don’t turn off DC input breaker under the inverter with load, otherwise it will cause DC input

breaker damaged.

1.4 When the machine happen MOD, overload, output error and fault alarm, turn off the DC input

breaker to restart the machine.

1.5 Put the inverter on ventilated and away from sunlight, confirmed the machine and wall distance

is greater than 30cm.

1.6 Don’t block the vents, if found the vents blocked, please clean up in time.

1.7 When the inverter is running normally and temperature is rising. If the fan stop working,

please replace the fan in time. (The starting temperature of the fan is 45°C).

1.8 Recommend to turn on the output circuit breaker firstly, then turn on start switch. Make the inverter

starting load, can effectively avoid the damage of large inrush current to the machine.

1.9 Don’t connect ground wire (GND) of cabinet and neutral wire (N) together.

17
Solar Sine Wave Inverter www.lgis.cc
2), Notice:
2.1 All operations of equipment must be done by professionals, please remove metal jewelry on hands

before the operation in case of electric shock !

2.2 The inside cooling fan of the machine is controlled by temperature, it’s a normal phenomenon that

the fan is not running when inverter just start soon or taking little load, the fan only will run when cabinet

internal temperature exceeds 45 ℃.

2.3 When the machine is working, in case of accidents and to avoid electric shock, please don’t open the

cover of cabinet.

2.4 Please don’t make change to the circuit line privately when regular checking, in case of damage.

2.5 It’s a normal phenomenon that the inverter has a certain degree of fever during the use process, but

should keep the environment of installation ventilated, cooling and clean, especially can’t block air

ventilator.

2.6 The inside all CMOS components of the machine can’t touch, when the circuit is powered on don’t

connect or disconnect the wires and terminals.

2.7 After connect all wires, please must be carefully check (voltage value, positive and negative pole are

consistency, grounding is well).

2.8 Even if the all switch on the panel is OFF, but inverter’s part of capacitor still electric, please don't

touch.

2.9 When take with motor and pump or other inductive loads, the inverter had best leave 30% of the

power margin, should be considered the impact current to the machine, to ensure reliable power supply

to inverter

3), Regular checking


To ensure SDP series inverter continuously and normally running, it is required regular maintenance,

usually every six months for regular inspections.

Before opening the cover of cabinet maintenance, should completely cut off the power and shut down

inverter 10 minutes or longer, after capacitors end discharging, then can proceed maintenance ( the

machine inside has many capacitors and discharge need some time), be careful not to damage any

parts and components, pay attention to the order of wiring.

18
Solar Sine Wave Inverter www.lgis.cc

Parts Check the contents Solutions


Input and output
loose Tightening
terminals
The cable whether is
Input and output cable Replace cable
aging
Accumulation of dust Using 392kPa-588kPa pressure dry
Control board
and dirt compressed air to blow off
Bus capacitor Discoloration or smell Replace capacitor
Radiator Fan Not work Replace fan
Accumulation of dust Using 392kPa-588kPa pressure dry
Inside of cabinet
and dirt compressed air to blow off
LCD doesn't display Replace the CR1220 Button Cell on the
Button cell
Time motherboard

4), Troubleshooting

Fault phenomenon Fault reason solution method

Check the battery is normal


Check the DC input voltage (battery
voltage) and positive, negative connection
DC input abnormal are correct
Check there has any displays in the LCD,
The inverter can’t start such as overvoltage or under-voltage of
battery
DC input breaker is ON Check DC input breaker

Output overload or short Close the load, check whether there has
circuit breakage or short circuit of load cable

When the inverter is in the


normal state, still no AC AC output breaker is ON Check AC output breaker
output

19
Solar Sine Wave Inverter www.lgis.cc
10. After-Sales Service
Sales staff cooperate with Engineering department, delivery the products that meet the

needs of users and be in good condition to the user. Terms are stipulated as following:

We usually adopt entrust transport way to delivered the goods, when the user sign for the

goods by delegating transport, should carefully check whether the structure and

appearance of product is damaged, if with doubt, the user shall not sign for it, if you sign for

it then means you agree the goods without any fault or damage during transportation.

1. Our company seriously promised: For all sold out inverter, we provide one year warranty

from the date of delivery and supply maintenance services all the time.

2. Within warranty time, when inverter meets all the installation environment and using

conditions, also operation correctly, if the inverter have damage or accident happens,

please inform our company after-sales service department, when contact us, please

provide the equipment model, serial number and complete problem explanation. We will

provide free components for replacement firstly, if the problems still can't be solved, please

contact the manufacturer as soon as possible, prohibit remove the parts by yourself !

However, any of the following situation happened, are not included in the warranty:

3.1 Damage caused by any modification or repair privately and without company's

permission.

3.2 Damage because of an irresistible natural disasters and man-made damage.

3.3 Damage caused by supply power not according to the electrical specification or the bad

environment.

3.4 Damage caused by not following user manual’s security items and using instruction

3.5 Damage caused by without the permission of the company maintenance person,

disassemble, repair, modification or add additional accessories privately.

3.6 Irresistible natural disasters.

20

You might also like