Cable break The slider voltage is in the cable break area.


Check the cabling to this angle transducer.
Hints for troubleshooting:
• The angle transducer may not be supplied with power or has moved
out of position too far. A cable break on the power supply is possible
too.
Use the PC service software to measure the voltage on the
corresponding analogue input.
• Voltage > 4.8 V:
- Short circuit of the slider to 24 V.
- Angle transducer too far out of position?
- Cable break of the ground signal
• Voltage < 0.2 V:
- Short circuit of the slider to ground or against vehicle mass
- Cable break between slider and angle transducer.
- Cable break between power supply and angle transducer.
- Angle transducer too far out of position?
• Potentiometric transducers “530 xxx”:
For precise localization, measure the following resistances with the
steering computer unplugged:
- Between terminal +5V-Ref and ground. As min. 2 tracks are
connected in each case, approx. 1000 Ohm (750 – 1250 Ohm)
should be measured. In the event of deviations, there is a cable
break / short circuit of the output "5V-Ref." or of "0V-Signal".

Short circuit Short circuit between the two angle transducer tracks.
Check the cabling to this angle transducer.
Parameter prog Parameter P_64 programmed incorrectly.
Signal failure Both signals of the angle transducer are instable or erroneous. This
occurs in conjunction with other errors at this angle transducer.

Hints for troubleshooting:


• The other errors give more detailed information about the kind of the
signal failures.
• Observe the signal voltages and check them for irregularities.

EHLA_Manual_Part 4_V0100_G4 2 Alarm list