0% found this document useful (0 votes)
2K views4 pages

Adjustment Procedure of B-Axis Zero Return Position - Rotary Table Specification

1. This document provides procedures to adjust the zero return position of the B-axis on an NHX4000 machine with an MSX-853 controller. 2. The procedures involve using a dial indicator to find the machine zero point of the B-axis relative to the pallet, then setting the relative and absolute position values in the controller. 3. Once the zero return position is established, the procedure checks that the B-axis returns correctly to parallel with the X-axis on zero return operations.

Uploaded by

mahdi elmay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views4 pages

Adjustment Procedure of B-Axis Zero Return Position - Rotary Table Specification

1. This document provides procedures to adjust the zero return position of the B-axis on an NHX4000 machine with an MSX-853 controller. 2. The procedures involve using a dial indicator to find the machine zero point of the B-axis relative to the pallet, then setting the relative and absolute position values in the controller. 3. Once the zero return position is established, the procedure checks that the B-axis returns correctly to parallel with the X-axis on zero return operations.

Uploaded by

mahdi elmay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Page 1/4

SERVICE MANUAL Manual No. SV01-NHX40TB03-01E

Machine NHX4000 Controller MSX-853 Component Table


Adjustment Procedure of B-axis Zero Return Position
Title
(Rotary Table Specification)

z Adjust and establish the zero return position of B-axis according to the following procedures.
< Attention >
When the servo batteries are consumed, replace those with new ones before performing
this procedure.
< Attention >
This procedure begins with the “ APCHP ” (APC Home Position) lamp on the machine
operation panel illuminates.

1. Change the setting of “ ZERO POINT ADJUSTMENT ” to “ VALID ” on the OPERATION


PANEL screen.
∗ Whether the setting is present or not depends on the production years of the machine.
It is unnecessary when there is no “ ZERO POINT ADJUSTMENT ” in OPERATION
PANEL screen.
• Display the OPERATION PANEL screen.
Press SETTING function key → Press [ F1 ] “ OPE. PANEL ” soft key
→ Press [ F6 ] “ OPE PANEL ” soft key
• Change the setting of “ ZERO POINT ADJUSTMENT ” to “ VALID ”.
Move the cursor to the “ ZERO POINT ADJUSTMENT ” by ↑ ↓ cursor
movement keys → Press → cursor movement key to select “ VALID ”

AUX. FUNCTION LOCK OFF ON

MACHINE LOCK OFF ON

ZERO POINT ADJUSTMENT INVALID VALID

2. Select the manual mode and press the B CLAMP button on the machine operation
panel to unclamp the B-axis.
When B-axis unclamp is completed, the lamp of the B CLAMP button turns OFF.

3
2
1 2011/2/18 New Version Sakai
Version YY /MM /DD Changes Corrected By
Specified Production Month Approval Issued By
For Electronic
Machines From June 2010 (No.1) Yoshida Distribution Sakai

CF2165-901A-02
SERVICE MANUAL SV01-NHX40TB03-01E Page 2/4
Adjustment Procedure of B-axis Zero Return Position
Title
(Rotary Table Specification)

3. Move the B-axis to the machine zero point.


< Attention >
When moving the axis, make sure no obstructions are present within the moving area,
and also do not approach the moving area.
• Remove the edge locator (200 mm length) from the pallet on the table of inside the
machine.
• Polishing the edge locator installation surface of the pallet by whetstone to remove
the dirt and the wound.
• Mount the Magnet Stand attaching the Dial Indicator to the surface of the spindle.
• Move the X-, Y-, and Z-axis by manual pulse generator to the position where the probe
of Dial Indicator comes in contact with the edge locator installation surface of the
pallet.
The reading of the Dial Indicator is set to “ 0 ” at this position.
• Move the X-axis while adjusting the B-axis by manual pulse generator so that reading
of the Dial Indicator when probe of Dial Indicator moves in side surface of the pallet
may become within 0.008 mm/200 mm.
Dial Indicator
Edge Locator
+X

Spindle

Pallet -X

Dial Indicator
Spindle
Pallet

• This position is the B-axis machine zero point.


∗ If B-axis zero point arrow index marks are present, make sure that the positions of
the index marks are aligned.
4. Set the value of < RELATIVE > coordinates of B-axis to “ 0.000 ” at the B-axis machine
zero point.
• Display the < RELATIVE COORDINATE > of CURRENT POSITION screen.
Press POSITION function key → Press [ F2 ] “ REL. ” soft key
→ Display the < RELATIVE COORDINATE > of CURRENT POSITION screen.
• Set the value of < RELATIVE > coordinates of B-axis to “ 0.000 ”.
Press B of the data input key → Press [ F10 ] “ ORIGIN ” soft key

CF2165-901A-02
SERVICE MANUAL SV01-NHX40TB03-01E Page 3/4
Adjustment Procedure of B-axis Zero Return Position
Title
(Rotary Table Specification)

5. Display the screen of the Absolute Position Set of B-axis.


• Press the SYSTEM function key to display the INPUT/OUTPUT screen.
• Press the [ F3 ] “ NC SYSTEM ” soft key to display the screen of Process Parameter.
• Display the screen of the Absolute Position Set.
Press [ Y ] soft key → Press [ F1 ] “ Mainte ” soft key → Press [ F6 ] “ To Abs pos ”
soft key → Display the screen of the Absolute Position Set
• Press the [ F8 ] “ Prev axis ” or [ F9 ] “ Next axis ” soft key to display the B-axis.

B
Type No Stopper
State Illegality
Machine end 0.000
Machine posn 0.000
No.
1 Absolute Posn set 0
2 Origin-P 0
3 Zero-P 0.000

6. Establish the zero return position of B-axis.


• Set the “ Absolute Posn set ” to “ 1 ”.
Move the cursor to the “ Absolute Posn set ” → Press 1 of the data input key
→ Press INPUT button → Display of “ State ” changes to “ Origin Set ”
• Set the “ Zero-P ” to “ 0.000 ”.
∗ It executes only when there is a value in “ Zero-P ”. (it is unnecessary when the
value is “ 0.000 ”)
Move the cursor to the “ Zero-P ” → Press 0 of the data input key
→ Press INPUT button → Display of “ Zero-P ” changes to “ 0.000 ”
• Set the “ Origin-P ” to “ 1 ”.
Move the cursor to the “ Origin-P ” → Press 1 of the data input key
→ Press INPUT button → Display of “ State ” changes to “ Ret. Ref. P. ”
• Move the B-axis in the “ - ” (minus) direction by manual pulse generator to establish
the zero return position.
The display of the “ State ” changes to “ Complete ” when zero return position of
B-axis is established.
7. The value of “ Machine end ” of Absolute Position Set screen is input to “ Zero-P ”.
• Check the value of “ Machine end ” of screen of Absolute Position Set.
• Set the value of the “ Machine end ” you checked to “ Zero-P ”.
Move the cursor to the “ Zero-P ” → Input the checked value by data input key
→ Press INPUT button → Display of “ Zero-P ” changes to inputted value

CF2165-901A-02
SERVICE MANUAL SV01-NHX40TB03-01E Page 4/4
Adjustment Procedure of B-axis Zero Return Position
Title
(Rotary Table Specification)

B
Type No Stopper
State Complete
Machine end -1.321
Machine posn 0.000
No.
1 Absolute Posn set 0
2 Origin-P 0
3 Zero-P -1.321

8. Reset the NC power.


9. Perform the B-axis zero return operation.
• Select the manual mode and press the B CLAMP button on the machine operation
panel to unclamp the B-axis.
• Turn the B-axis approximately 50 degrees in the “ - ” (minus) direction by manual
pulse generator.
• Press the ZRN mode selection button to select the Zero Return mode.
• Press the +B manual axis feed button to perform the B-axis zero return.
• The “ B ” status indicator lamp on the machine operation panel illuminates when zero
return is completed.
10. Make sure that the zero return position of the B-axis is parallel to the X-axis movement.
• The probe of Dial Indicator comes in contact with the edge locator installation surface
of the pallet.
• Make sure the reading of the Dial Indicator when probe of Dial Indicator moves in
side surface of the pallet is within 0.008 mm/200 mm.
∗ Refer to step 3 for the checking method.
11. When the established zero return position is correct, the adjustment is completed.
Remove tools including the Magnet Stand and the Dial Indicator, which are used for the
zero return position adjustment.
Install the edge locator to the pallet on the table of inside the machine.
12. Make sure the B-axis moves properly without problem by manual and MDI operations.