Meter
Meter
Meter
PPurpose off
Water Meter
- Water Usage control & Energy Saving
- Control water loss
1 Measurement for process control
1. - To avail volume data
Billings
g
Class A - for
Cl f raw Class B for household
water or waste water supply
water
Class C
Class D for Oil & Gas
P t bl water
Potable t
Production process
Of the water meter
Casting Type
Materials
กระบวนการอัดั ใใสแ บบ
กระบวนการอัดแบบทราย
กระบวนการอดแบบทราย
F
Foundry
d
Pouring Process
Cool Down
Machining / Finishing
Painting
Machining by CNC
Testing of Body
Testing of
plastic parts
Assemble of
number gears
Assemble
sse b e
Register
units
Accuracy test & Leakage Test
Type of The Water Meter
Single
g & Multi Jet Type
yp
Pistol Type
Flow Meter
Electromagnetic, pulse meter and etc
Single-Jet
Single Jet Water meter
Multi-Jet Water meter
DRY DIAL
Water
Water
Horizontal Woltman
Vertical Woltman
Di it l
Digital
Di i l Water
Digital W Meter
M
Development
p
มาตรวัดนํ้าแบบลูกสูบ
แสดงคาเปนระบบ Digital
Di it l Water
Digital W t Meter
M t
How to Select the
Right water meter
The water demand and usage is different.
The type of water meter also different
Laundry 20 – 40 Liter/head/day
Liter/head/day
Airport 15 – 25
The use of water meter to match with the water consumption
Size Range of the Water Usage
Normal Flow Maximum Flow Remark
Inch
c (mm)
( ) ( CUM
CU / Hr)) (CUM/Hr)
(CU / )
1/2 (15) 1.5 3 Equipments
3/4 (20) 2.5 5 Pipe Size
1 (25) 3.5 7 Sanitation
1 1/2 (40) 10 20 Kitchen & etc
2 (50) 15 30 Should also be
3 (80) 40 80 Considered
4 (100) 60 120
6 ((150)) 150 300
8 (200) 250 500
10 (250) 400 800
12 (300) 600 1,200
Select -Easily
Easily worn out
Too Small -Inaccuracy
Water Meter -Pressure lost
-Inaccuracy
Select
-High
g cost
Too Big
Accuracyy
Alignment
Avoid Dirt Water
What cause Water Meter Has
Sh t Life
Short Lif Span
S
Lack of schedule maintenance
Number Gear Stop movement due to dirt stuck
Adhesive from PVC Pipe flow into the chamber
ร
Modification by means of fraud
Quality of the water
Expired
p
Damaged Seal
Theft
et
Maintenance
The maintenance schedule should be
set Every 4 years
To Do Maintenance
1. Disassembled for cleaning of every parts
and assemble all pieces into places.
2 Leakage test for and accuracy test to
2.
perform according to standard
3. Maintenance records
Disassemble
สวนประกอบมาตรวัดน้ํา
Model : MBA-p
Cleaning
Rust Remover
Testing of Water Meter
-Test pressure Water meter must withstand pressure
g
17.2 bar at least one minute without leakage.
-Test pressure loss maximum flow rate of up to 1 bar.
-The accuracy test The volume of water measured
for Each of the flow rate will not exceed tolerances.
+5 percent for the low side and no more
than +2 percent the high side
ISO 4064 : 2005 Standardization
R = 100 is the ratio of
Normal flow rates (Q3) the minimum flow rate (Q1).
Q3
R= = 100
Q1
Q1 = Qmin
i Q4
= 1.25
Q3
Q2 = Qt
Q2 = 1.6
Q3 = Qn Q1
Q4 = Qmax
แบบ R100 จะทําใหสามารถวัดประสิทธิภาพของมาตรวัดน้ํา
ในชวงของอัตราการไหลที่กวางขึ้น
Specification for cold water meter
(R100) No. WM.013/0 MWA.
Size mm. (inch)
h Q3 (m3 /hr.)
/h )
15 (1/2) 2.5
20 (3/4) 40
4.0
25 (1) 6.3
เปรียบเทียบขนาด 15 mm.
Qmax Q4 Qu Q3 Qt Q2 Qmin Q1
สรุป ชว ง High Flow จะสูงขึนึ้ ชว ง Low Flow จะตํา่ํ ลง ทํําให
ใ ช วงกวา งขึน้ึ แตค า % Error เทา เดิมิ