Case Study Bangalore

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

BANGALORE

J.NAJEELA BANU
M.DEEEKSHI ANGELIKKA
P.PADMA PRIYA
A.SALAMATH SAMEERA
FUNCTIONS:
BLOCKS
A ADMIN BLOCK
B FACULTY BLOCK
C CLASS ROOMS
D COMPUTER AND CANTEEN
BLOCK
E,F GIRLS HOSTEL
G LIBRARY
H AMPHITHEATRE
J AUDITORIUM
NEW BLOCK

BANGALORE-CASE STUDY
CORE FUNCTION

1.THE INSTITUTE COMPLEX PERIPHERAL ACTIVITY


▪ Administrative block
▪ Academic block
▪ Laboratories fashion design block 2.RESIDENTIAL BLOCK
▪ Hostel blocks for boys & girls
▪ Kitchen & dining hall

FUNCTIONS 3.PUBLIC AREAS


▪ NIFT designer shop
▪ ADMINISTRATION ▪ Library & resource centre
▪ ACADEMICS
▪ COMMON FACILITIES
▪ HOSTEL FOR STUDENTS

BANGALORE-CASE STUDY
1.THE INSTITUTE COMPLEX CORE FUNCTION

CORE ACTIVITY
INSTITUTE COMPLEX
SUPPORTIVE ACTIVITY ▪ LECTURE HALL
EDUCATION ▪ Exhibition space ▪ STUDIO
▪ Auditorium ▪ LIBRARY
▪ Seminar hall ▪ LABORATORIES
SUPPORTIVE ACTIVITY ▪ Canteen courtyard ▪ WORKSHOP
▪ Recreation
▪ FACULTY ROOM
▪ Interaction
▪ Commercial
SERVICE
CIRCULATION ▪ Electrical
▪ Public ▪ Toilets
SERVICE ▪ Semi public ▪ HVAC
▪ Electrical ▪ Private ▪ ATM parking
▪ Water supply
▪ Drainage
▪ HVAC CIRCULATION
▪ Passages
▪ Staircases
▪ OA
BANGALORE-CASE STUDY ▪ Workshop space
2.RESIDENTIAL BLOCK CORE FUNCTION

SUPPORTIVE ACTIVITY
▪ Open space RESIDENTIAL
▪ Courtyard
RESIDENTIAL LIVING ▪ Recreational space ▪ HOSTEL
▪ Dining space
▪ Shops

SERVICE
▪ Electrical room
▪ Toilets
▪ Parking
▪ Kitchen
▪ HVAC

CIRCULATION
▪ Passages
▪ Staircases
▪ Open court
BANGALORE-CASE STUDY
DEPARTMENTS BLOCK A
ENTRANCE LOBBY AND
ADMINISTRATION
• FASHION DESIGN
• ACCESSORY DESIGN
• TEXTILE DESIGN BLOCK B
• KNITWEAR DESIGN FACULTY BLOCK
• FASHION COMMUNICATION
• APPAREL PRODUCTION BLOCK C
• FASHION MANAGEMENT ACADEMIC BLOCK
GARMENT CONSTRUCTION LAB
PATTERN MAKING LAB
CLASROOMS AND LABS

BLOCK D
COURTYARDS
RESOURCE CENTRE
LIBRARY
MATERIAL MUSEUM

BANGALORE-CASE STUDY
`
CANTEEN
COMPUTER LABS
CORRIDORS BLOCK E & F
HOSTEL FOR
GIRLS
BLOCK G
LIBRARY
BLOCK H
AMPHITHEATRE

BLOCK J
AUDITORIUM
BANGALORE-CASE STUDY
ZONING:
BLOCKS
A ADMIN BLOCK
B FACULTY BLOCK
C CLASS ROOMS
D COMPUTER AND CANTEEN
BLOCK
E,F GIRLS HOSTEL
G LIBRARY
H AMPHITHEATRE
J AUDITORIUM
NEW BLOCK

BANGALORE-CASE STUDY
SERVICES:PARKING AND SERVICE ROOM

•Safely and efficiently meet the


parking needs of faculty, staff,
students, and visitors.

• Parkings provided only for


staffs And not for students.
It is the drawback of the
campus. There is no
sufficient spaces for
parking.

• Utilize a variety of parking resources including surface


lots, decks, and parking garages
BANGALORE-CASE STUDY
SERVICES:CIRCULATION
• Service road runs all around the site and has
separate gates at Northeast and south

SERVICE ROAD
6m wide road
N
INTERNAL PATHWAYS

6m wide road

6m wide road

6m wide road

SERVICE ROAD EXTERNAL CIRCULATION CORRIDORS


[Wide 2m]
BANGALORE-CASE STUDY
SERVICES:CIRCULATION [COMPARED]

MUST: IN CAMPUS:
• STUDENT-Car park/garage-main entrance/subsidiary • STUDENT-Outside parking/students entrance-
entrance -lifts/staircases - corridors - lifts/staircases - corridors -Classrooms.students leaving
Classrooms.students leaving from class directly to the from class directly to the parking.
parking.
• NON TEACHING STAFF- Respective entrance--changing
• NON TEACHING STAFF- Main entrance-parking- rooms -kitchen/service rooms-service
changing rooms -kitchen/service rooms-service
lifts.
lifts.
• TEACHING STAFF- Staff entrance-parking-faculty block-
• TEACHING STAFF- Main entrance/service entrance- classrooms
parking-changing rooms - Respective spaces.
• HOSTELERS - Respective entrances-hostel
• HOSTELERS - Respective entrances-hostel
• VISITORS,if allowed- Main entrance- outside parking-
• VISITORS- Main entrance-parking-respective spaces respective spaces.
• DELIVERIES-Food, drink, stores-service or respective • DELIVERIES-Food, drink, stores-service or respective
entrance/service entrance- canteen. entrance/service entrance- canteen.
• 4 entries are provided main

SERVICES:ENTRY entry,students entry,staff entry and


service entry.
• If separate entry given,there will be no
circulation,traffic problems.
MAIN ENTRANCE

•All external pathways must also


accommodate bicycle circulation.

•The internal circulation network to connect to the external pathways and


open spaces increase ease of pedestrian movement through the campus.

BANGALORE-CASE STUDY
SERVICES:DRAINAGE SYSTEM CAMPUS CONTAINS GOOD DRAINAGE SYSTEM.

Rainwater, surface and subsurface water, drainage water


should be collected through respective systems.

BANGALORE-CASE STUDY
SERVICES:LIFT/STAIRS/RAMPS/FIRE SAFETY SYSTEMS

RAMPS:
• 1:6 RATIO

LIFTS:
• FIRE LIFT
• NORMAL LIFT

STAIRS: FIRE ALARM SYSTEMS:


• NORMAL STAIRCASE • SPRINKLERS
• FIRE STAIRS • ALARMS

BANGALORE-CASE STUDY
SERVICES:PLUMPING

• WATER SUPPLY TO RESPECTIVE


SPACES-OVER HEAD TANKS-
PIPELINES.
• Water Supply
• Drainage of Wastes
• Water Recycling Systems (these allow you to
recover the water from your waste and re-use
that water for low-grade applications such as
flushing)
• Rainwater Harvesting
• Storm Water Drainage

BANGALORE-CASE STUDY
BLOCK A-ADMIN BLOCK
STAIRCASE

FIRE EQUIPMENT
STAIRCASE
office PIPE LINE

STORAGE ENTRY

CORRIDOR
TOILET DIRECTORS
ROOM

LOWER FLOOR

BANGALORE-CASE STUDY
BLOCK A-ADMIN BLOCK
STAIRCASE

FIRE EQUIPMENT

PIPE LINE
STAIRCASE
ENTRY

MEETING BACKOFFICE
HALL CORRIDOR

TOILET DIRECTORS
ROOM

UPPERFLOOR

BANGALORE-CASE STUDY
BLOCK A-ADMIN BLOCK
STAIRCASE

FIRE EQUIPMENT

PIPE LINE

CLASSROOM STAIRCASE
ENTRY

STORAGE CORRIDOR

OFFICE
TOILET DIRECTORS
ROOM

FIRST FLOOR

BANGALORE-CASE STUDY
BLOCK B-FACULTY AREA
MACHINE
CLASSROOM
ROOM

KNITTING
MACHINE
LAB

STUDIO

BASEMENT PLAN
BANGALORE-CASE STUDY
BLOCK B-FACULTY AREA
STAIRCASE

FIRE EQUIPMENT

PIPE LINE
OFFICE OFFICE
ENTRY

CORRIDOR

TOILET

OFFICE
STAIRCASE

GROUND FLOOR PLAN


BANGALORE-CASE STUDY
BLOCK B-FACULTY AREA
STAIRCASE

FIRE EQUIPMENT

PIPE LINE
STAFFROOM
STAFF ROOM
ENTRY

CORRIDOR

TOILET

OFFICE
STAIRCASE

FIRST FLOOR PLAN


BANGALORE-CASE STUDY
BLOCK B-FACULTY AREA
STAIRCASE

FIRE EQUIPMENT

CLASS ROOM PIPE LINE

ENTRY

CORRIDOR

TOILET
OFFICE

STAIRCASE
LOCKER ROOM

2nd FLOOR PLAN


BANGALORE-CASE STUDY
BLOCK C-CLASS ROOMS
ELETRICAL
ROOM STAIRCASE

FIRE EQUIPMENT

GYM PIPE LINE


LOCKER
ENTRY

CORRIDOR

AD LAB COURTYARD
STUDIOS

GROUND FLOOR

BANGALORE-CASE STUDY
BLOCK C-CLASS ROOMS
ELETRICAL ROOM STAIRCASE

FIRE EQUIPMENT

PIPE LINE
PML
LOCKER ENTRY

CORRIDOR
STUDIOS
FT
COURTYARD
STAIRCASE

FIRST FLOOR

BANGALORE-CASE STUDY
BLOCK C-CLASS ROOMS
ELETRICAL ROOM
STAIRCASE

FIRE EQUIPMENT

LOCKER PIPE LINE

ENTRY

CORRIDOR

AD LAB COURTYARD STUDIO

STAIRCASE

SECOND FLOOR
BANGALORE-CASE STUDY
BLOCK C-CLASS ROOMS
ELETRICAL ROOM
STAIRCASE

FIRE EQUIPMENT

LOCKER PHOTOGRAPHY PIPE LINE


LAB
ENTRY

CORRIDOR
CLASS ROOM
AD LAB COURTYARD

MACHINE
LAB

STAIRCASE

THIRD FLOOR
BANGALORE-CASE STUDY
BLOCK D-COMPUTER AND CANTEEN
STAIRCASE

FIRE EQUIPMENT
STORE
PIPE LINE
LIBRARY
LAB ENTRY

CORRIDOR
COURT
CHESS

CANTEEN
KITCHEN

GROUND FLOOR
BANGALORE-CASE STUDY
BLOCK D-COMPUTER AND CANTEEN
STAIRCASE

FIRE EQUIPMENT
STUDIO
PIPE LINE
LABS
LAB STUDIO ENTRY

CORRIDOR
COURTYARD

LAB

SURFACE
DESIGN
STAFFROOM

BANGALORE-CASE STUDY FIRST FLOOR


BLOCK D-COMPUTER AND CANTEEN
STAIRCASE

FIRE EQUIPMENT

PIPE LINE
LABS
LAB ENTRY

COURTYARD CORRIDOR

TERRACE

TERRACE

SECOND FLOOR
BANGALORE-CASE STUDY
NEW BUILDING
STAIRCASE

FIRE EQUIPMENT

PIPE LINE
TOILET
ENTRY

LOCKER
CLASS ROOM ENTRY CORRIDOR
STAIRCASE
LIFT

STAIRCASE

GROUND FLOOR
BANGALORE-CASE STUDY
NEW BUILDING
STAIRCASE

FIRE EQUIPMENT

TOILET PIPE LINE

ENTRY
CLASS ROOM
LOCKER ENTRY
STAIRCASE CORRIDOR

LIFT
STAIRCASE

FIRST FLOOR

BANGALORE-CASE STUDY
NEW BUILDING
STAIRCASE

FIRE EQUIPMENT

PIPE LINE

ENTRY

CORRIDOR
TOILET
LIFT

CLASS ROOM
LOCKER ENTRY
STAIRCASE

STAIRCASE

FOURTH FLOOR
BANGALORE-CASE STUDY
AUDITORIUM
STAIRCASE

FIRE EQUIPMENT

PIPE LINE

ENTRY

CORRIDOR
Seat arrangements
Disco lights

Vertical fire pipe


BANGALORE-CASE STUDY
SERVICES INCLUDES:
• Electrical distribution and supply
• Escalators, lifts, ramps and stairs
• Facade engineering such as building shading requirements
• Fire safety, detection and protection
• Heating, ventilation and air conditioning (HVAC)
• Lighting
• Refrigeration
• Security and alarm systems
• Water, drainage and plumbing and other services such as
• Canteen services
• Security services
• Circulations
• Parking

BANGALORE-CASE STUDY