Dynamic Pump Final SHT - Explanation
Dynamic Pump Final SHT - Explanation
FOUNDATION PROPERTIES:
Concrete Compressive Strength (f'C): 30 N/mm2 Type C30
3
Concrete Density: 2400 Kg/m
Concrete Cover: 75 mm
FOOTING:
Min Length (L): 8.40 m
Thickness (E): 0.00 m
Min Width (B): 2.80 m
L =
2.80 m 2.80 m
Y 0.00 m
(0 , 0)
X PLAN
HPP 0.30 m
1.20 m
Z 0.00 m
(0 , 0)
ELEVATION FROM SOUTH
X
2.80 m
HPP 0.30 m
1.20 m 0.00 m
2.80 m
ELEVATION FROM WEST
PIER:
YCG(F) mf + YCG(E) mE
Y C.G(S) =
mf + mE
Uniform settlement will not occur in this particular case because the horizontal eccentricities in
any direction between the centre of gravity of the machine-foundation system and the centroid
of the base contact area din't exceed 5% of the respective base dimensions.
Mass Moment of Inertia of foundation about its CG axis (Mass Moment of Inertia (Table 4-6)/ P.61)
for foundation Δx = distance between C.G of foundation to the base of foundation
Element miΔxi2 (Kg miΔz2 (Kg miΔy2 (Kg Ixoi Izoi Iyoi
s2 cm) s2 cm) s2 cm) (Kg s2 cm) (Kg s2 cm) (Kg s2 cm)
F1 0 0 0 0 0 0
P2 38252 130244 22 763991 5769289 5236998
Equivalent Radius ( R ): (Reqd for Kz) 273.69 cm Arya,O'Neil & Pincus Tab. 4-2
Embedment Coefficient (ηz): (Reqd for Kz) 1.18 Arya,O'Neil & Pincus Tab. 4-2
Equivalent Spring Constant (Kz): 3.610E+06 Kg/cm Arya,O'Neil & Pincus Tab. 4-1
Mass (Inertia) Ratio (Bz): (Reqd for Dz) 0.50 Arya,O'Neil & Pincus Tab. 4-3
Damping Ratio Embedment factor (αz): (Reqd for Dz) 1.44 Arya,O'Neil & Pincus Tab. 4-4
(Reqd for caluclation of Resonance frequency)
Damping Ratio (Dz): 0.86 Arya,O'Neil & Pincus Tab. 4-3
Natural Frequency (fnz): 1/2pie x sqrt K/M) 1691 rpm Arya,O'Neil & Pincus P.19
Frequency Ratio (fo/fnz): 2.10
(Reqd for magnifying unbalanced force)
Magnification Factor (Mzp): 0.20 Arya,O'Neil & Pincus Tab. 1-4
Resonance Frequency (fmz): Not Possible Arya,O'Neil & Pincus Tab. 1-5
(f = kx, x = f/k where f= magnified unbalanced force, x= displacement)
Displacement response: 7.479E-06 cm Arya,O'Neil & Pincus checklist
(percentage of unbalanced force transferred to foundation)
Transmissibilty Factor (Trz): 0.75 Arya,O'Neil & Pincus Tab. 1-4
RESONANCE CHECKING:
0.7 fo 2492
1.3 fo 4628 NO RESONANCE
fo-Primary 3560 rpm 59.333 Hz
RESONANCE CHECKING:
0.7 fmz 2492
1.3 fmz 4628 NO RESONANCE
fo-Primary 3560 rpm 59.333 Hz
RESONANCE CHECKING:
0.7 fmz 2492
1.3 fmz 4628 NO RESONANCE
fo-Primary 3560 rpm 59.333 Hz
RESONANCE CHECKING:
0.7 fmz 2492 rpm
1.3 fmz 4628 rpm NO RESONANCE
fo-Primary 3560 rpm
RESONANCE CHECKING:
0.7 fmz 2492 rpm
1.3 fmz 4628 rpm NO RESONANCE
fo-Primary 3560 rpm
RESONANCE CHECKING:
0.7 fmz 2492 rpm
1.3 fmz 4628 rpm NO RESONANCE
fo-Primary 3560 rpm
CALCULATION OF AMPLITUDE
Displacement amplitudes based on uncoupled modes of vibrations
Top of pedestal
P1 Point 1 Point 2
X 8.40 8.40
Y 0.00 0.00
Y Z 2.80 0.00
P2
Top of pedestal
X
POINT 1
Xi 840.00
ZI 0.00
Yi 280.00
Xi - Xcg(S) 398.95
ZI - Zcg(S) -113.85
Yi - Ycgi(S) 140.50
Displacement Amplitude
Amplitudes, cm Peak to Peak(2A) ZONE Table 3.2
Ax 0.0000080 0.000016 A
Arya, Oneil & pinkus -
Az 0.0000076 0.000015 A Table 3.3
Ay 0.0000080 0.000016 A
Displacement velocity
V=2πfA
ZONE Table 3.2
Vx 0.0000299 m/sec A
Arya, Oneil & pinkus -
Vz 0.0000285 m/sec A Table 3.3
Vy 0.0000299 m/sec A
Fh(x) 99.001 kg
Fh(z) 101.878 kg
Fh(y) 99.001 kg
MΨ 34.743 kg - cm
MΦ 138.785 kg - cm
Mγ 0.000 kg - cm
According to to ACI 318, Chapter 7, the steel reinforcement to be used shall be: