Clip Angle Connection: Design Forces
Clip Angle Connection: Design Forces
Clip Angle Connection: Design Forces
Job :
PPD : Date : Checked : Rev.
ISA50X50
Design forces ###
L/C Beam Node ###
p
n Fx = 6 Fy = 78 Fz = 0 ###
p (Enter member forces in kN only) ###
###
Supported Member* ###
Web depth = 300 Flange width = 175 ###
Bolt group 1 Web thk. = 6 Flange thk. = 14
ed (* - All dimensions in mm)
Connection details
g Angle = ISA100X100X10
No. of rows (n) = 2 Dia. of bolt (do) = 20
Grade of bolt = 8.8
ed Shank area (Ag) = 314 mm2
Bolt group 2
Net area (An) = 245 mm2
Design checks :
Check for shear
Shear capacity of bolt in =
f ub
nn An ns Ag = 60.4 kN (nn = 1, ns=0)
3 * mb
single shear (Vdf)
Shear capacity of bolt in =
f ub
nn An ns Ag = 120.7 kN (nn = 2, ns=0)
3 * mb
double shear (Vdf)
= 323 kN
= 6.7 kN-m OK