Flexi RF Module 3TX 2100 (FRGT)

FRGT technical specifications.

Functional description

Table: FRGT functional specification

Property Value

Output power 3x80 W

MIMO 2TX

Outdoor installation Yes

SW supported technologies WCDMA, FDD-LTE

TX frequency range 2110-2170 MHz

RX frequency range 1920-1980 MHz

DL instantaneous bandwidth 60 MHz

UL instantaneous bandwidth 60 MHz

DL filter bandwidth 60 MHz

UL filter bandwidth 60 MHz


Table: FRGT output power in RU40 release and onwards

DL Output power
bandwidth

0-20 MHz 80 W

20-45 MHz 70 W (BTS can be commissioned as 80 W (for example 4x20 W per pipe) and RFM internal
power control limits the total power to 70 W when needed.)

45-60 MHz 60 W

Interfaces

FRGT interfaces
Place the cursor over the table or module for more information. Interface Label on the HW Number
of interfaces Connector type Additional info Power connector DC IN1 Screw-in terminal Antenna
connector AN 67/16RF output connector RxO 3 QMA Remote Electrical Tilt RET1 8-pin circular
External Alarm Connection EAC1 RJ45 Optical interface OPT3 SFP 3 Gbps or 6 Gbps
Antenna Line Devices (ALDs) support

Table: FRGT ALD support

ALD support via antenna ports Value

AISG ANT1, ANT3, ANT5, RET: AISG 2.0

CWA (for non-AISG installations) Yes

Voltage ANT1, ANT3, ANT5: 24 V or 12 V

ANT2, ANT4, ANT6: 12 V

RET: 24 V
Power per port 30 W

Functional block diagram

Figure: FRGT functional block diagram

Electrical specifications

Table: FRGT electrical specifications

Property Value
Nominal supply voltage -48.0 V DC

Nominal input voltage range -40.5 V DC to -57.0 V DC

Extended input voltage range -36.0 V DC to -40.5 V DC

-57.0 V DC to -60.0 V DC

Power consumption

Table: FRGT power consumption

Mode Configuration Output Estimated power consumption [W] at 48VDC input at 25°C. Non-
power committed estimated values depend on the final product HW and
per SW optimization with +/- 10% margin. Average = (6h low hour
carrier load, 10h medium hour load and 8h busy hour load) / 24h
[W]

Power consumption Power consumption Power


consumption
ETSI 202706 average ETSI 202706 busy
load PRRH, static hour load PBH RRH, 100% RF power
static load P100% RRH

WCDMA 1/1/1 20 287 316 386

2/2/2 20 356 414 547

3/3/3 20 437 522 729

4/4/4 20 494 608 885

LTE 1/1/1 2T2R 20+20 580 651 796


1/1/1 2T2R 40+40 711 843 1117

1/1/1 2T2R 60+60 818 1010 1427

1/1/1 2T2R 80+80 976 1232 1803

MSR WCDMA 2/2/2 20 719 847 1126

LTE 1/1/1 20+20


2T2R 10MHz

WCDMA 2/2/2 20 926 1141 1661

LTE 1/1/1 40+40


2T2R 10MHz

Table: Recommended FRGT power backoff in 256 QAM mode

Single carrier [dB] Dual carrier [dB]

0.8 0.8

Installation and mechanical specifications

Table: FRGT installation and mechanical specifications

Property Value

 floor/stack installation
Installation options
 pole installation
 wall installation
 19'' rack/cabinet

IP rating IP65
Related optional items Pole installation
 Flexi Mounting Kit for Floor, Wall and Pole (FMFA)
 Flexi Pole Kit (FPKA)
 Flexi Pole Kit (FPKC)
 Flexi Module Casing (EMHx)
Floor/Wall installation
 Flexi Mounting Kit for Floor, Wall and Pole (FMFA)
 Flexi Module Casing (EMHx)
Outdoor 19'' rack
 Flexi Module Casing (EMHx)
Cabinet/indoor 19''' rack
 No optional items needed

Dimensions and weight

Table: FRGT dimensions and weight

Property Value Dimensions orientation

Height Core RFM: 115 mm (4.5 in.)

Depth Core RFM: 400 mm (15.7 in.)

Without front covers: 422 mm (16.6 in.)

With front covers: 560 mm (22.1 in.)

Width Core RFM: 420 mm (16.5 in.)

Without front covers: 447 mm (17.6 in.)

With front covers: 492 mm (19.4 in.)

Weight 25 kg (55.1 lb)

Volume 19.3 l

Environmental specifications
Table: FRGT environmental
specifications

Property Value

Maximum operational outdoor temperature (at constant high ambient temperature +55°C (131°F)
maximum output power might be limited)

Minimum operational temperature (including cold start) -35°C (-31°F)

LEDs

Table: FRGT LEDs

LED color Description Alarm

Red, stable Critical alarm Fault


affecting the whole
RF module or all
antenna carriers

Major/critical
Red, blinking Operation alarm
degraded

 Major alarm
affecting the
whole RF
Module
 Major alarm
affecting the
whole RF
Module
 Major/Critical
alarm affecting
a module
subcomponent
or antenna
carrier

Yellow, stable  Until software No alarm


download
begins
 The carriers are
blocked from
BTS
 There is no
connection to
any System
Module

Yellow, blinking  Software No alarm


download in
progress
 Configuration in
progress: RF
resources are
being setup, but
not yet
activated

Green, stable  Software No alarm


configuration is
complete or
supervisory: RF
resources
activated and
transmission is
possible
 Working
normally, no
alarm on the
RF Module

Green, blinking Software No alarm


downloading and
updating

Stable Red for less than 5 seconds and changes to Stable Yellow Switched ON, but No alarm
the next conditions
are not reached yet

Stable Red for less than 5 seconds The module is in No alarm


the process of
resetting

Periodic Red and Green Antenna line Alarm


faulty/degraded
due to external
factors (for
example, VSWR
minor/major values
exceeded, Antenna
line device
faulty/degraded)
Blinking Colors (Red, Yellow, and Green), each color stable for 0.5 second Module highlighting No alarm
(Flexi BTS SM
functionality that
can help identifying
faulty module)

RF Module fan/TX status LED: Red At least one fan is -


faulty or degraded

RF Module fan/TX status LED: Green All fans are -


working

RF Module fan/TX status LED: Color set according to fan status, stable RF transmission is -
ON

RF Module fan/TX status LED: Color set according to fan status, blinking RF transmission is -
OFF
Warnings, cautions or notes related to the product

You might also like