Smoke Detectors For Fire Alarm Systems
Smoke Detectors For Fire Alarm Systems
Smoke Detectors For Fire Alarm Systems
OAP P D2 - - -
OAP PB D4 - - -
BEAM200, OAP PB D2 - - -
BEAM200S
FSB-200, OAP PB D2 - - -
FSB-200S,
JTY-H-
FSB-200S
OSI-R-SS OAP PB D4 - - -
OSI-RI-SS OAP PB D2 - - -
Velocity
Range Date Time of Firmware
Detector Compatibility (fpm) of Manufacture Version
Firmware
Model Application Type Restrictions Min Max Manufacture Version Update
P(IHD) None - - -
OAP P D2 0 1000 - - -
D4120 (w. 2D51 head)(e), D4240 (w. 2D51 head)(e), TD41203 (w. 2D51 head)(e), TD41204 (w. 2D51
head)(e), LD4120X (w. 2D51 head)(e), LD4120H (w. 2D51 head)(e), TD4C (w. 2D51 head)(e), D4S (w.
2D51 head)(e), PD4120 (w. 2D51 head)(e), YD4120 and YD4 (w. 2D51 head)(e), JCID4120 (w. 2D51
head)(e)
ED-DPIA D P None - - -
ED-PIA P None - - -
HFS-P P None - - -
HFS-PT P None - - -
Pressure
Differential
Velocity Between
Range Sampling Date Time of
Detector Compatibility (fpm) Tube of Manufacture
Firmware
Model Application Type Restrictions Min Max Min Max Manufacture Version
Control Unit
Compatibility
Base Model Related Detector Restrictions
B401, B110LP, B110RLP, B112LP(RS), B114LP(RS), (BT), B116LP(RS), B401BH, B401B, B401LP,
B401R, B402B(RS), B404B(RS), B404BT, B406B(RS), B401BH-2, B401BR
B801RA 882 B2
EBS (d) ED-PTI, ED-PT, ED-PI, ED-P, ED-II,63-1058, 63-1059, 60-1040, 67- B2
034, 63-1052, 63-1053, 60-1039, 67-033, TC906A1002, TC906A1010,
TC908A1000, TC907A1001
RMK400 (n), 1251, 1451, 2151, 2151T, 2251, 2251B,2251BR, 2251TB, 2251TBC, None
SMB 600 (n) 2251TMB, 2251TMBC, JTY-GD-2451, 2451 (Heat Detectors)
B2 - For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters.
Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit.
B7 - Determined by head.
D1 - Listing limited to specific system control unit. Information on compatible control unit indicated on installation drawing of
control unit and/or detector.
D2 - For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters.
Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit.
D5 - For use only with Listed control units with which compatibility was determined by test.
D7 - The detector head is used with a separable base where the base determines function and connection.
*1 - For connection to Listed Control Unit, Model ZXa manufactured by Morely with which compatibility was determined by test
or a review of circuit parameters. Interconnection and compatible models are indicated on installation wiring diagram for
Detectors and/or control units.
*2 - For connection to Listed Control Unit, Shark Series 10 056 manufactured by Fike Protection with which compatibility was
determined by test or a review of circuit parameters. Interconnection and compatible models are indicated on installation
wiring diagram for Detectors and/or control units.
*3 - For connection to Listed Fike model Cybercat fire alarm control panel.
*4 - For connection to Listed fire alarm control panel, models Vista-32FB, Vista-40, Vista-50, Vista-50P, Vista-100, Vista-128B,
Vista 128BP, Vista128BPADT, Vista-128FB, Vista-128FBP, Vista-250BP, Vista-250FBP, FA1220C, FA1220CV, FA1340C, FA1600C,
FA1660C, FA1700C, Focus 200 Plus and Focus Cadet, manufactured by Honeywell Security.
P - Photoelectric
RS - Releasing Service
PB - Projected Beam
I - Ionization
D - Duct Detector
Date of Manufacture identifies the manufacturing start date of all product models that will use the specific Time of
Manufacture Firmware Version. The date of manufacture is noncoded and in the format YEAR (in 4 digits), MONTH (in letters),
DAY (in 2 digits).
Time of Manufacture Firmware Version identifies a numerical and/or alphabetic series designation that is product and date-
code specific and will only identify the Firmware Version at the time the product was manufactured. The numeric and/or
alphabetic sequence is defined by the manufacturer.
Firmware Version Update is a numerical and/or alphabetic sequential identification that is product and date-code specific and
sequentially identifies the Firmware Version Update from the previous version of firmware. The numerical and/or alphabetic
sequence is defined by the manufacturer.
(ab) - Suitable for use in Special Application installations with certain system alarm sensitivity settings.
(b) - Model is not to be sold or distributed in the United States of America.
(c) - Suitable for duct application, installation inside duct, only when used with Model B404B, B404BT or B114LP base and
Model RTC remote test kit.
(g) - Model 2D51 smoke detector for use in duct smoke detectors Models D4120, D4120W, P270-3000PL, TD41203, TD41204,
LD4120X, LD4120H, TD4C, and duct smoke detector sub assembly Model D4S only.
(i) - DNR and DNRW duct housing can be used with the following compatible detector heads: FSP-851,FSP-851R, SD355, SD-
355R,ASD-PL2F, 2951ADT, NP-100, 2951J, 2251FB, 2251B,2251BR, IDP-PHOTO, TC806B1076, TC806DNR,MIX-2251B, and MRI-
2251B.
(n) - Recessed mounting base RMK400 is only to be used with bases B401, B501, and detector Models 1251, 1451, 2151, 2151T,
2251, 2251B, 2251BR, 2251TMB, JTY-GD-2451, 2451 (Heat detectors).
(o) - To be installed in moderate climates where the ambient air temperature will not fall outside the range of 32F to 131F (0C
to 55C).
(p) - Special application, system sensitivity may be set between 0.02 and 0.5 percent per foot obscuration.
(r) - Duct housing can be used with the following compatible detector heads: Models 63-1062, 63-1057, and TC906D1006
(s) - For a D(I) application the unit will only operate with the RA100Z remote test accessory. All other accessories cannot be
used in this configuration.
(w) - Model number may be followed by a two digit suffix, indicating the color of the enclosure: -WH for white, -IV for ivory, -BL
for black, etc.
(x) - Model number may be followed by a suffix, indicating the color of the enclosure: -WHITE for white, -IV for ivory, -BL for
black, etc.
(z) - Suitable for use in Special Application installations with system sensitivity setting between 0.02 and 0.5 percent per foot
obscuration.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified
and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:
1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their
entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from
the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the
reprinted material must include a copyright notice in the following format: "© 2020 UL LLC"