【Symptom】
When copying cloth as an original, the printed color becomes reddish.
【Cause】
This symptom occurs when a specific cloth is used.
When a specific type of cloth that reflects infrared rays is used, the infrared area will be
read as more reddish than the original.
【Countermeasure】
There is no countermeasure on this series.
In order to improve this symptom, it is necessary to change the lens to a type that has
the ability to cut the infrared rays. The parameter of the image processing also needs to
be modified.
【Cause】
The dust is stuck on the window of PH.
In the production line, the cleaning stick (pad) was
damaged when the PH was installed to main body, then,
the dust was attached on the cleaning pad.
【Countermeasure】
The checking process on the production line was
improved.
【Cause】
The rotation of the polygon motor is not stable.
This is caused by the fixing failure of a GND
screw which should be fixed on the polygon
motor board in the PH.
【Countermeasure】
Improved the inspection process of above
operation on production line.
【Cause】
The operator/CE makes a mistake in the
installation.
If the drum unit is installed without removing
the protection material, there is the possibility
of damaging the surface of the drum unit by
touching the DS roller.
4. Spot on Drum Unit (2/2)
Before
After
【Countermeasure】
The design of the protection material will be changed to a “foolproof” design. (*Please
see the above pictures for details.)
【Ref.】
TAD No.: TABT0900207****
5. FD White line (Drum)
【Symptom】
White line (FD) occurs.
【Cause】
The main reason could not be found. Although one of the reasons considered was dirt
on the electric charger of the drum.
【Countermeasure】
N/A
【Estimated Reason】
The connection failure of HV board (A0EDM40202) to main body.
--- This symptom was resolved by removing and re-installing the HV board.
【Countermeasure/Action】
N/A
7. Gradation Adjustment (1/2)
【Symptom】
FEET (rear edge side) of gradation adjustment output looks abnormal. It is different with
color tone or gradation adjustment.
【Cause】
FEET gradation adjustment is the image processing mainly applied to the edge parts of
letters. It is comparably difficult to converge the targeted gradation as this mode has
less gradation steps. So this image is specification.
【Symptom】 Fig.1
- Light Image
- Disappearing Image A4
【Cause】
The contacting failure is occurred on the contact pin of the 2nd
transfer holder which is supplied the voltage from the main
body.(Fig.2)
The toner cannot be carried to the paper correctly due to the
enough voltage cannot be supplied to the transfer section by
the contacting failure.
Factor of the contacting failure
- The size of the contact pin on the 2nd transfer unit cannot be fitted to the main
body side correctly.
8.Image Failure on the leading edge(1/2)
【Action in the field】 Fig.2
【Permanent Countermeasure】
The design of the length of the contact pin
Fig.3
was changed in order to keep the enough
contact stroke to the main body.
【Reference】
TAD No.: TABT1000781EN01
9.Abnormal Image(P-5,P-28,P-21)
【Symptom】 Fig.1
【Cause】
IDC sensor failure.
【Estimated reason】
1.Flat cable (Disconnect – connect or Replace)
2.PH (Replace)
3.MFP board (Replace)
4.PRCB board (Replace)
10.Slanting image(Black)
Fig.1
【Symptom】
The slanting image is printed out in a short time after installing the main
body.(Fig.1)
【Cause】
No or a few black developer in the developing unit.(Fig.2)
There is the possibility that the black developer is dumped into the waste
toner box by the vibration during the shipment of the brand new machine
with the long distance by the track.
【Cause】
Bad electrical contact between CN5PH
and PWB-PH ASSY.
16
12. Image quality problem caused by MFP board (2/2)
Case 3
Case 4
Original
17
13. (1) Thick paper Jam on Tray1
(2) Paper Jam (with plain paper) on Vertical Transport section
【Symptom】
1. When Thick paper is fed from Tray1, the edge of
the paper will be caught on the edge of the transport
guide, and paper jam occurs. [JAM code: J11XX]
2. When plain paper is fed from Tray2,3,4, the edge of
the paper will be caught on the edge of the transport
guide, and paper jam occurs. [JAM code : J20XX]
【Cause】
There are possibilities that the following types of
failure are produced on the holder (transport).
P/N A0ED7010
- bump (refer to the right picture)
- burr
【Countermeasure】
Modified the mold.
【Action in the field】
If the above symptom occurs, clean up the “bump” or
“burr” on holder (transport) by using sand paper. bump
【Other information】
TAD No.: TABT1000113****
14. 1st Tray Paper Jam (J1144)
【Symptom】
Paper Jam occurs in the paper feed section of 1st Tray. [JAM code : J1144]
【Cause】
The JAM detection timing have not enough allowance , when the paper feed slipping is
large.
【Countermeasure】
Even if the sensor in front of tim. Roller (PS1) is turned on when the judging to retry 1st
and bypass paper feed, paper transportation is continued without stopping
jam(J1144/J1044).
【Action in the field】
[Download file name]
A0ED0Y0-F000-GC7-B4.EXE
Program Name:Printer “A0ED0Y0-0050-G10-05” or later
【Other information】
TAD No.: TABT1000404****
15. Wrinkles on Envelope (1/2)
【Symptom】
Rear side of
The wrinkles may occur on the envelope
rear side of an envelope.
(For details of the wrinkles,
refer to the picture on the
right.)
【Cause】
Too much pressure was
added by the fusing roller
when printing the envelopes.
There was a variation of
spring tension from lot to lot.
Back side
15. Wrinkles on Envelope (2/2)
Spring for envelope
Spring for plain paper
Cause①
【Cause】
The rigidity of paper decreases with the moisture uptake.
The buckling distortion of paper is occurred by "sliding resistance with the guide and bump' at
transportation route.
16. Paper Jam in paper exit section(J3205) (2/2)
【Countermeasure】
Putting up the countermeasure parts when J32-05 is occurred.
A0ED-7414-00 Guide Film
A0ED-8972-00 Slide Tape
【Other information】
TAD No.: TABT1000333****
17. Paper Jam in paper exit section (J3205) (2) (1/2)
• Due to the Guide Film added, the item code of the Fusing Unit has been changed.
A0EDR72011 -> A0EDR72022 : Fuser unit(120V)
A0EDR72111 -> A0EDR72122 : Fuser unit(200V)
A0EDR73811 -> A0EDR73822 : Fuser unit(110V)
• The shape of the ribs of the Guide has been changed as next page. (4-parts)
A0ED890401 -> A0ED890402 : Guide
【Ref. 】
TAD No.: TABT1000333EN01
PMN No.:KOM101179
18. Display “Paper Jam” on the additional cassette
【Symptom】
After machine is turned ON, the “Remained Paper Jam” may be detected on Tray3,
or Tray4.
【Cause】
The reason is the timing of the initial communication between main body and
optional cassette when turning on. It takes 16.6 ms to complete the initializing
communication and sensor checking, then, if the door is opened by any action
during initializing, there is possibility that the detection of remained paper will be
detected.
【Countermeasure】
Modified the completing time of the initial communication and sensor checking.
【Cause】
When the original is inversed by the inversing roller, the punched holes are scratched by the PET
mylar. (P/No: A0HT-7060-00).
【Countermeasure】
Modified the type of PET mylar. (P/No: A0HT-7060-01)
Applied Machine Number
A0HUWY1117557 and onward
【Other information】
TAD No.: TABT0900189****
PMN No.: KOM100901**
19. Damage of the punched holes (2/2)
【Cause】
The bend of the terminal pin(Fig.2) in the ADF connector causes
the contacting failure.
Factor of the bend on the terminal pin
When ADF connector is inserted to the main body obliquely, the
connector pin is bent with by the burr in interference. Fig.2
【Permanent Countermeasure】
The mold for ADF connector which prevents the burr was changed from
Oct/2010.
21.DF-617 Skew of Original Paper
【Symptom】
When the original paper is fed in the duplex mode, there is the possibility Fig.1
that the scanned image on the 2nd side is skewed or a part of image is
defected. (Fig.1)
【Cause】
The pressure of the plate spring which presses the roller(Fig.2) is stronger
than the standard, so, the original paper is skewed to the rear side direction.
【Permanent Countermeasure】
The plate spring was changed Fig.3
【Cause】
Light blocking plate [A01H 5601 **] of lifting plate [A01H 5607 **] doesn't down to detecting
position of the sensor [A108 M501 00], because of bracket interfere with the rib of tray.
【Countermeasure】
Cutting the rib interfering with bracket of tray [A01H 5601 **]
Applied product: A0HUWY1134643 and onward
【Other information】
TAD No.: TABT1000344****
PMN No.: KOM101282**
24.Original misfeed (J6602) in the DF (1) (1/3)
【 Symptom 】
There is a possibility that the original misfeed (J6602) occurs on the DF.
【Object product】
DF-619 (C652DS/C552DS)
DF-618 (C652/552/452)
DF-617 (C360/280/220)
【Cause】
There was a small burr on the paper guide on the Upper Cover, the leading edge of
paper is stopped before the separation rollers. The burr is a parting line of the
molding.
24.Original misfeed (J6602) in the DF (1/2)
【 Symptom 】
There is a possibility that the original misfeed (J6602) occurs on the DF.
【Object product】
DF-619 (C652DS/C552DS)
DF-618 (C652/552/452)
DF-617 (C360/280/220) Cover Upper
(A0HT5608)
【Cause】
There was a small burr on
the paper guide on the
Upper Cover, the leading
edge of paper is stopped
Rear side
before the separation Front side
rollers. The burr is a
Burr on the parting line No burr on this side
parting line of the molding.
24.Original misfeed (J6602) in the DF (2/2)
【Action in the field】
File the burr with sandpaper (ISO Grit size P1000 to P1200).
File the burr by sandpaper on the direction of red arrow.
Note: Do not file the burr too much because the burr is on the paper guide.
【Reference】(TABT1000347EN01)
【Effective Se/No. 】 PMN: KOM101105
25.Original misfeed (J6602) in the DF(2) (1/2)
【Symptom】
ADF paper feed section Jam for DF-617 (J66-02) .
【Cause】
The separator pad peeled off.
There was a case defect the spare parts as well.
【Countermeasure】
The separator pad of double-stick tape has been modified
We modified to use more stronger type of double-stick tape for the separator pad.
We will issue this PMN (Parts Modification Notice) soon.
【Reference】 TABT1000495EN01
26. Stapling failure with FS-529 (1) (1/2)
【Symptom】
Output paper can not be stapled with the correct position because the paper skew occurs when
the paper is returned to the collecting position when stapling.
【Cause】
The cause is the deformation of the mylar (A0U7-PP9S-00) on holder. The friction between belt
and paper decrease by the deformation of the mylar. Accordingly, the power balance between
front side and rear side of pulling back paper is disordered. As a result, paper don't align.
The mylar deform because the mylar may touch with the guide (A0U7-PP7B-00).
OK NG
NG OK
26. Stapling failure with FS-529 (1) (2/2)
【Countermeasure】
The guide (A0U7-PP7B-00) was shaped modification.
Applied Machine Number
A0U7WY1014076 and onward
A0U7WY2000001 and onward
【Other information】
TAD No.: TABT1000218**** This point was cut
PMN No.: KOM101316**
Guide (A0U7-PP7B-00)
27. Stapling failure with FS-529 (2) (1/2)
【Symptom】
Output paper can not be stapled correctly, because the paper cannot be collected to the
regular position when stapling.
【Cause】
Paper alignment can fail because the frictional force of the POM roller is too low.
This issue can easily occur with light weight paper.
【Countermeasure】
Modified the type of POM roller to roller with rubber.
Applied Machine Number
A0U7WY1014077 and onward
A0U7WY2000001 and onward
urethane sheet
28. Stapling failure with FS-529 (3) (1/2)
【Symptom】
Output paper can not be stapled with the correct position.
【Cause】
Paper alignment guide is installed incorrectly.
1) If the following measurement is longer than 11mm when Peper alignment guide is
in home position, Paper alignment guide is installed incorrectly.
11mm 11mm
Between touching
paper face and cover
11mm
NG OK
Incorrect position Correct position
29. C-1191 with FS-529 (1/2)
【Symptom】
C-1191(Alignment plate F drive malfunction) might be occurred at out of box.
【Cause】
The point of the alignment plate F was caught to the hole of the frame , and the motor
stopped.
[Before] [After]
【Countermeasure】
The hole of the frame was modified.
Date of modification:29/10/2009
Effective S/N:A0U7WY1008477~
【Other information】
TAD No.: TABT1000425****
29. C-1191 with FS-529 (2/2)
Move and contact the alignment plate to the front frame,
and vibrate it to front, back, left and right direction.
When it could not be released it even if it vibrates , desorbs the alignment plate few times
with holding the condition that the alignment plate and front frame are contacting.
(Picking the tip and pull it in the direction of the arrow.)
【Phenomenon】
Some users point out that moving sound occurred when the UP/DOWN Tray is
moving down to home position after completed the job is uncomfortable.
【Change】
UP/DOWN Tray does not move down to home position after complete the job
and it starts to move to home position when starting the next job.
【Reference】
DLBT1002259EN00 Finisher Ver.A0U70Y0-0071-GC1-04
31.Detection Failure of JS-505/FS-527 (1/2)
Fig.1
【Cause】
The connector pin of FNS relay harness is dropped out. (Fig.1)
nFactor of the pin drop out
The terminal of the connector pin of “JS-505 or FS-527” is bent. (Fig.2)
If the connecter of JS-505 or FS-527 is inserted the FNS relay harness, the connector pin is dropped out
by the interference which is caused by the bending of the terminal pin of JS-505/FS-527.
nFactor of the bending of the connector pin
Manufacturing failure on the pressuring process of the connector pin.
31.Detection Failure of JS-505/FS-527 (2/2)
Fig.2 Fig.3
【Permanent Countermeasure】
-Strengthen the quality management of the pressuring accuracy for the connector pin.
-Strengthen the inspection process on shipment.
32. JAM Problem in FS-529 (J72-17) (1/2)
【Symptom】
JAM(J72-17) occurs frequently in FS-529.
【Cause】
A) FW problem of FS-529 (incorrect setting of the Duty ratio of transportation motor.)
This problem occurs mostly on larger than B4 size.
B) JAM processing lever doesn't lock enough.
【Countermeasure】
A) Correction for incorrect setting of current value of transportation motor.
Countermeasure FW Ver.: A0U70Y0-0071-G01-04
B) Fill the gap between D cut part of shaft and lock lever by modifying the shape of D cut part.
Applied product S/No.: AOU7WY2015605 and onward
【Other information】
DL No.: DLBT1001299****
TAD No.: TABT1000813**** D cut part
49
32. JAM Problem in FS-529 (J72-17) (2/2)
【Action in the field】
Update the firmware to Ver. A0U70Y0-0071-G01-04 or later.
If JAM occurs frequently even after updating the firmware, check the following.
1) Attach a Mylar with the lower guide of paper 2) Check the screw securing conveyance roller unit
entrance. (Perform this action on FS-529 which and the positioning dowel.
Model No. is only A0U7-WY1.)
Check the damage of the
positioning part. (Plastic part)
3) Fill the gap between D cut part of the shaft and lock lever. (If 2) is no problem, perform this action.)
Dimension of Mylar
Length -> 10mm
Width -> 3mm
Thickness -> 0.1mm
Attach Mylar on the face of
D cut part by double-faced
Fill the gap between the shaft and lock lever. tape.
50
33. FS-529 C-1183
【Symptom】
C-1183 (Elevate drive malfunction) is occurred.
【Cause】
Damage of worm gear [A0U7 PPBJ 01]
Worm gear
【Countermeasure】
Change the module of the appropriate gear.
Change other gear together and strength Tray
up/down Assy.
Applied products: A0U7WY1014536 and onward
A0U7WY2006753 and onward Tray up/down Assy
[A0U7 PPD0 00]
【Action in the field】
Replace Tray up/down Assy [A0U7 PPD0 00] or
damaged worm gear [A0U7 PPBJ 01]
【Other information】
TAD No.: TABT1000656****
PMN No.: KOM101127**
34. JAM (72-87) occurs at the Center Staple
in Fold mode on SD-509 (1/2)
【Symptom】
The JAM (72-87) occurs when the 1st sheet of 2nd set is stuck on the Center
Staple in Fold mode.
【Condition】
If all of the following conditions below 1), 2) and 3) are selected, this problem
should be occurred.
1) Center Staple & Fold mode “0.8mm”
2) Paper size: 11X17 only
3) Half-Fold position in 11x17: “0.8mm”
【Countermeasure】
Released improved firmware (A10D-0Y0-0071-G00-03) for SD-509 in bizhub C452
and bizhub C360/C280/C220.
New firmware (Maintenance release Ver. 58 and onward) in available on the CSES.
【Action in field】
This problem occurs, when the Half-Fold position was set as 11x17: “0.8mm” ONLY
Set the figure to something except 0.8mm in the Half-Fold position 11x17.
【Reference】
(TABT0900181EN01)
35. Wrong Booklet Tray Full Detection on SD-509 (1/2)
【Symptom】
There is a possibility that the machine stops and displays the Tray Full warning
when only a few booklets have exited. This could happen when low stiffness
paper is used for the booklet and it is made up with only a few sheets of paper.
【Cause】
If the above mentioned booklet can not push up the arm on the booklet tray
(Lever/1), the booklet stops at the end of the arm and the trail edge of it can not
fully exit. This trail edge activates the tray full sensor and the machine stops and
displays the tray full warning.
【Symptom】 【Measure】
【Reference】
(TABT1000156EN00)
36. Paper alignment failure on FS-527 (1/2)
【Symptom】
A5 paper alignment trouble and staple failure on the FS-527 was found in the
production line.
This trouble has never been reported from the field.
【Condition】
Paper: A5LEF
Finishing mode: Staple mode
【Cause】
Because the Swing guide plate (A0HR715900) sometimes can not swing up
quick enough, the second sheet of paper could not enter underneath the guide
correctly before hitting the edge of it. This causes the misalignment of the sheets.
36. Paper alignment failure on FS-527 (2/2)
【Measure/ Action in field】
The pressure force of the Swing guide plate spring has been increased.
Parts Number
Old: A0HR 2257 00 >> New: A0HR 2257 01
Spring Specification
Old: 0.154N >> New: 0.2N
【Reference】 (TNBT1000043EN00)
37. Operational noise from JS-504/505 (1/2)
【Symptom】
There were several complaints from the Japanese market regarding the operational
sound of JS-504/505. To decrease operational sound, additional grease has been
applied to the gears on the JS-504/505 on the production line.
A0832102
A0831056
Side
A0832100
A0832101
【Reference】 (TNBT1000027EN00)
【Effective Se/No. 】PMN: KOM100846
38. C-5501 (AC signal abnormality) (1/2)
【Symptom】
"C5501" might sometimes be occurred in warming up, waiting or printing.
There is a possibility that this trouble code might occur if the machine is located near some
electrical noise such as a construction site, the private electric generator etc.
【Cause】
"C5501" checks the frequency of the power supply, and when the frequency becomes abnormal
because the noise gets on the power supply line, this trouble is detected.
(* Refer to the following waveform.)
If the noise occurs continuously on the
marked position, the abnormal frequency
will be detected.
38. C-5501 (AC signal abnormality) (2/2)
【Countermeasure】
The countermeasure firmware which improves the noise detection for the AC signal has been
prepared.
<Notes:>
The control of the fusing heater doesn't work correctly when it cannot detect the frequency of the
power supply. Therefore, the trouble code of the fusing temperature error might appear.
Therefore, the function of C5501 was newly added because of a power supply environmental
check.
However the machine works correctly even if it deletes C5501.
【Other information】
TAD No.: TABT1000021****
39. C-B001
【Symptom】
When the machine is warming up, C-B001 is detected after the FAX board is installed
to the main body.
【Cause】
Check Sum error.
The check sum error occurs because the main body was turned OFF during ISW.
【Countermeasure】
N/A. This trouble is caused by the mistake of the operator.
【Countermeasure】
There is the possibility that the connection between FAX board and the relay board
(MK-720) is loose.
【Countermeasure】
N/A
[Others]
1. Replace Main Drive Assy.
2. Update the firmware.
42. J14-01 when setting up PC-207
【Symptom】
J14-01 occurs when setting up PC-207.
【Cause】
The poor connection occurs because of No.1 pin of [CN39] on PC-207 connects with
crushed.
【Action in the field】
Check Trouble Shooting on service manual and connection of [CN39], if J14-01 occurs
when setting up PC-207.
CN39
66
43. Custom size is returned to Auto detection
【Symptom】
The registered custom paper size of the bypass tray will be returned to Auto detection.
One of the cases for the occurrence condition is,
1. Set the paper of custom paper size to the bypass tray.
2. Register the custom size.
If the horizontal width for the registered paper size is near 114mm (between B6 and A5), it is easy for this
symptom to occur.
【Cause】
The sensitivity of resistance in the bypass tray is too tight. The resistance value is changed, when the guide is
put to the position of the paper size switching, and then the change of paper size is detected and returned to Auto.
【Countermeasure】
The countermeasure firmware which has the correct level of the sensitivity for the detection of the paper size.
【Cause】
The cause is the unevenly sensitivity of sensor .
This problem occurs by the sensor of too high sensitivity and wide detective range. The
sensor detects the magnet at the position that must not react normally. So “Toner near
empty” is detected, although toner still remains in Sub Hopper Assy.
68
44. Detection failure of “Toner near empty” (2/2)
【Countermeasure】
“The lead switch selected in the production line is used.
Sub Hopper
Old P/No.: A0ED-R***-00 → New P/No.: A0ED-R***-01
【Cause】 【Countermeasure】
The lever of the front door falls into the following Shorten the distance shown on the picture by
space (shown with red arrow below) on the using the correct Torsion coil spring.
safety switch, then, “Front door open” is detected.
The space on the safety switch is created if the
Torsion coil spring is too short. It was found that
【Action in the field】
there is a variation in the size of parts.
Current P/No :A0ED136700
New P/No :A0ED136701
Replace with the correct “Torsion coil spring”.
【Other information】
TAD No.:TABT1000013****
PMN No. :KOM100274
46.Broken NVRAM connector
【Phenomenon】
Panel freeze (KM logo or Hourglass mark)
Panel turns off / Trouble code CD390, CC164, CC170 display
Memory indicator does not reset after copy or print comes out.
【Cause】
NVRAM connector is broken
【Countermeasure】
Replace MFP board
Option DIMM
Slots for DIMMs (UK-203)
【Cause】 on MFP board
【Permanent Countermeasure】
The internal data of DIMM was corrected. The following type of labels(Green/Orange)
are attached to the corrected DIMMs. (Fing.1)
- Green : attached in the new production process of the DIMM supplier.
- Orange : attached in the factory after re-writing the data to the returned DIMM.
Fig.1
【Reference information】
TAD No.:TABT1000705EN00
48.Trouble with Std. DIMM
【Symptom】
There’re possibilities that the following symptom Std. DIMM
are occurred by the failure of standard DIMM.
- Repeat the Hourglass mark
- Freeze the operational panel with the
Hourglass mark
- Black panel
- C-C170/172/186
【Countermeasure】
Follow the service manual first when the above symptom are happened in the main body.
If the symptom cannot be resolved by the countermeasure which is mentioned on the service manual,
Replace the DIMM(Memory Module : V8653000025).
49. Message on the panel (1/2)
【Symptom】
The panel displays message ‘ Due to alert, the panel is illuminated ‘.
【Cause】
This message is displayed on MFP panel when receiving print order which has
mismatched information for the MFP in sleep (or Low power) mode.
(It may display by other reason. )
75
49. Message on the panel (2/2)
【Example】
When sending print job which is set punch and staple to MFP equipped with JS-505
and DF-617 in sleep mode.
(Because there are no punch and staple function with JS-505)
After MFP displays the message on the panel, print job is output without punch and
staple processing.
【Cause】
The abnormal noise "Kee" might occur because of the
rubbing of the tooth plane on the worm gear.
【Countermeasure】
When the abnormal noise occurs, execute the temporary solution (1)
or the temporary solution (2) .
<Temporary solution (1)>
Add two spacers (40383595) to the mounting plate to expand the
backlash (see slide 2/2).
<Temporary solution (2)>
Add weight (A0ED2313) to gear (A0ED2542). generation source
(The rotation of the gear is stabilized, and the vibration is decreased.)
<Permanent solution>
The part (A0ED2314) that integrates the gear with the weight is
newly established.
50. Abnormal noise in the fuser pressure release motor (2/2)
【Other information】
TAD No.: TABT1000022****
51. Noise from neutralization brush (1/2)
【Symptom】
The abnormal sound created by the scratching of the neutralization brush on the
exiting paper.
【Cause】
The amount of adhesive bond for neutralization brush was too much and the brush was
fixed (glued together) by this bond.
Neutralization brush
51. Noise from neutralization brush (2/2)
Current New
【Countermeasure】
Sound could be reduced by reducing the amount of adhesive bond and therefore the
quality of the brush becomes softer.
【Cause】
From the C353 series, the function which controls the fusing heater when “heat ON/OFF”, “wake
up/down” smoothly was added.
When this function works, the sound occurs by resonating the coils.
【Countermeasure】
Prepare the countermeasure firmware which does NOT smoothly work the control for the fusing
heater to improve the sound.
For the future plan, this controlling of the fusing heater can be switched by a Soft Switch.
【Symptom】
Sound occurs when feeding the Thick paper. It is louder compared with the normal
paper.
【Cause】
This sound occurs because the feeding paper vibrates the motor.
To realize the optimization of the fusing ability, the paper transportation speed is
controlled by changing the motor pulse when Thick paper is fed.
【Countermeasure】
A mylar sheet was added on the metal frame
under the PWB area.
This has been applied on the production line
since Sep/2009.
【Other information】
TAD No.: TABT0900153****
55. Noise occurs when feeding paper in ADU
【Phenomenon】
Noise occurs when printing 2-sided A3 paper in ADU.
【Cause】
The sheet of paper with moisture uptake produced large loop at the guide and this loop
generate the resistance and noise occurs.
【Countermeasure】
Adjust Resist. Value to more + side or – side.
56. Abnormal Noise from the scanner section
【Symptom】 Fig.1
The abnormal noise is occurred
The abnormal noise is occurred from the scanner when the mirror units are slide.
section when installing the main body.
When the 1st/2nd mirror unit are moved, the frame
and the plastic bush on the mirror unit are interfered.
【Cause】
The grease was not enough to the plastic bush on
the mirror unit and the frame.
The plastic bush are located on
the back side of the frame of
【Action in the field】 mirror units, please add the
grease here.
Add the grease to the plastic bush on the 1st/2nd mirror
unit.(Fig.1)
(1st/2nd mirror, front/rear side : 4 points)
57. Tray comes out
【Symptom】
There is a possibility that the feed tray could come out.
【Countermeasure】
The power of the spring for the lock lever was improved.
【Other information】
TAD No.: TABT0900211****
58. Tearing off Neutralizing brush from Cover Output (1/2)
【Symptom】
Neutralizing brush (A02E8907**) fixed on the Output Cover (A0ED8901**) may tear OFF as per the
below picture. This will affect the alignment of feeding paper to the Output tray.
【Cause】
If there is not enough adhesive power in the neutralization brush, this brush may be peel off.
The conductive tape of the neutralization brush is rubbed by the earth spring, when the paper exit
cover is opened and closed.
Paper Exit Cover: P/No. A0ED8901** Neutralization brush: P/No. A02E8907**
【Countermeasure】
Added the conductive tape (P/No. 40363075**) to the neutralization brush to improve the strength.
【Other information】
TAD No.: TABT0900184****
PMN No. : KOM091422**
58. Tearing off Neutralizing brush from Cover Output (2/2)
59. Cable Cover cannot be closed completely (1/2)
【Symptom】
There are two possibilities where you cannot close the cable cover completely….
1. In the case where the cabinet is NOT used, the cables cannot be boxed up around the cable exit position.
2. In case where the cabinet is used, cables are run on the cover.
【Cause】
1. Cables cannot be fixed completely.
2. There is no function to fix the cover.
59. Cable Cover cannot be closed completely (2/2)
【Countermeasure】
The design of cover was changed (as per the following picture) to the type where two cord clamps
can be set.
Also 2 pcs of the cord clamp are bundled in the brand new machine as standard accessories.
Recommendation
【Countermeasure】
Put the LAN cable, CSRC cable etc as recommended (in the right
picture).
In either case, where the cabinet will be used or not used, install
the clamp and fix the cables as necessary.
60. 2nd paper feeding guide is broken
【Symptom】
2nd paper feeding guide is broken by user when clearing paper JAM.
【Cause】
If 2nd paper feeding guide is pull strongly, the guide bend and overlap the stopper and
catch on the stopper. The guide is broken when right door is close unawares.
【Countermeasure】
Strength Actuator detecting paper JAM at exit section.
Current P/No.: A0ED 8207 01 -> New P/No.: A0ED 8207 02
【Other information】
TAD No.: TABT1000758**** Actuator detecting paper
JAM at exit section
PMN No.: KOM110018**
Broken actuator
92
62.Left side cover can’t be replaced
【Contents】
This left side cover can’t be replaced since this cover
is a part of main flame.