Fibre Optic Cables: Belden
Fibre Optic Cables: Belden
Fibre Optic Cables: Belden
Belden
15
Indoor Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 15:8
Indoor/Outdoor, Tight Buffer, Rodent Central Loose Tube Outdoor with Corrugated
Resistant, LSNH . . . . . . . . . . . . . . . . . . . . . . . . . 15:2 Steel Tape Armour . . . . . . . . . . . . . . . . . . . . . . . 15:10
Central Loose Tube Indoor/Outdoor LSNH Loose Tube, Indoor/Outdoor with
Unarmoured Rodent Resistant . . . . . . . . . . . . . . . 15:3 Rodent Protection . . . . . . . . . . . . . . . . . . . . . . . 15:11
Central Loose Tube, Indoor/Outdoor with Steel Central Loose Tube, Indoor/Outdoor with
Wire Armour LSNH . . . . . . . . . . . . . . . . . . . . . . . . 15:4 Rodent Protection . . . . . . . . . . . . . . . . . . . . . . . 15:12
6
Application
7
Mini-Breakout Cables Tight Buffer for outdoor and indoor use in structured wiring systems, such as Campus and Building
Backbone and/or Horizontal cabling. Easy to install in ducts, tunnels and trenches, it is not recommended for direct burial.
8 These cables are Halogen-free (FRNC and LSNH). Orange outer jacket, multimode and single-mode: OM1, OM2, OM3 and OS1.
9 Specifications
• Universal cable: indoor/outdoor applications • Water tightness according to IEC60794-1-2-F5
10 • Tight Buffer • Temperature Range:
• Swellable reinforced yarns as strength members and for Transport/storage: -30˚C to +75˚C
longitudinal water tightness Installation: -5˚C to +50˚C
11
• FRNC/LSNH orange jacket according to IEC60332-2 and Operation: -30˚C to +70˚C
IEC60754-2
12
Anixter Number Vendor Number Description
Multimode 62.5/125 0M1 Tight Buffer Cable Indoor/Outdoor
13
370-922-6LS8-04 GUMT104 4 fibre multimode cable OM1 62.5/125
370-922-6LS8-06 GUMT106 6 fibre multimode cable OM1 62.5/125
14 370-922-6LS8-08 GUMT108 8 fibre multimode cable OM1 62.5/125
370-922-6LS8-12 GUMT112 12 fibre multimode cable OM1 62.5/125
370-922-6LS8-24 GUMT124 24 fibre multimode cable OM1 62.5/125
15 Multimode 50/125 OM2 Tight Buffer Cable Indoor/Outdoor
370-922-5LS8-04 GUMT204 4 fibre multimode cable OM2 50/125
16 370-922-5LS8-06 GUMT206 6 fibre multimode cable OM2 50/125
370-922-5LS8-08 GUMT208 8 fibre multimode cable OM2 50/125
370-922-5LS8-12 GUMT212 12 fibre multimode cable OM2 50/125
17 370-922-5LS8-24 GUMT224 24 fibre multimode cable OM2 50/125
Multimode 50/125 for 10GB/s Applications OM3 Tight Buffer Cable Indoor/Outdoor
370-922-5LS8OM3-04 GUMT304 4 fibre multimode cable OM3 50/125 for 10Gb/sec application
18 370-922-5LS8OM3-06 GUMT306 6 fibre multimode cable OM3 50/125 for 10Gb/sec application
370-922-5LS8OM3-08 GUMT308 8 fibre multimode cable OM3 50/125 for 10Gb/sec application
19 370-922-5LS8OM3-12 GUMT312 12 fibre multimode cable OM3 50/125 for 10Gb/sec application
370-922-5LS8OM3-24 GUMT324 24 fibre multimode cable OM3 50/125 for 10Gb/sec application
Single-mode 9/125 OS1 Tight Buffer Cable Indoor/Outdoor
20 370-922-8LS8OS1-12 GUMT812 12 fibre single-mode cable OS1 9/125
370-922-8LS8OS1-24 GUMT824 24 fibre single-mode cable OS1 9/125
Application 7
Central Loose Tube Cables for outdoor and indoor use in structured wiring systems, such as Campus and Building Backbone
and/or Horizontal cabling. Easy to install in ducts, tunnels and trenches, it is suitable for direct burial. These cables are 8
Halogen-free (FRNC and LSNH). Simple all dielectric cable construction with standard rodent protection. Orange outer jacket,
multimode and single-mode: OM1, OM2, OM3 and 0S2.
9
Specifications 10
• Universal cable: indoor/outdoor applications • Water tightness according to IEC60794-1-2-F5
• Central Tube, jelly filled • Temperature Range: 11
• Swellable yarns as strength members and for standard Transport/storage: -30˚C to +75˚C
rodent protection Installation: -5˚C to +50˚C 12
• FRNC/LSNH orange jacket according to IEC60332-1 and Operation: -30˚C to +70˚C
IEC60754-2
13
6
Application
7
Central Loose Tube Cables for indoor/outdoor use in structured wiring systems, such as Industrial Backbone, Campus
Backbone, Building Backbone and/or Horizontal cabling. Suitable for direct burial and/or in ducts, tunnels and trenches.
8 These cables are Halogen-free (FRNC and LSNH) with a black outer jacket, multimode and single-mode, OM1, OM2 and OS2.
9
Specifications
10 • Full rodent protection • Crush resistance: =/< 30000 N/m
• For outdoor use, suitable for direct burial • Water tightness according to IEC60794-1-2-F5
• Water swellable yarns as strength members and for the • Temperature range:
11
longitudinal water tightness Transport/storage: -30˚C to +70˚C
• Halogen-free inner jacket Installation: -5˚C to +50˚C
12 • Steel Wire Armouring: helical stranded galvanised steel Operation: -30˚C to +70˚C
wires of 0.6mm
13
Anixter Number Vendor Number Description
14 Multimode 62.5/125 OM1 Loose Tube Indoor/Outdoor
372-BEL62-LTSWA-04 GUWN104 4 fibre multimode cable OM1 62.5/125
372-BEL62-LTSWA-08 GUWN108 8 fibre multimode cable OM1 62.5/125
15
372-BEL62-LTSWA-12 GUWN112 12 fibre multimode cable OM1 62.5/125
372-BEL62-LTSWA-24 GUWN124 24 fibre multimode cable OM1 62.5/125
16 Multimode 50/125 OM2 Loose Tube Indoor/Outdoor
372-BEL50-LTSWA-04 GUWN204 4 fibre multimode cable OM2 50/125
372-BEL50-LTSWA-08 GUWN208 8 fibre multimode cable OM2 50/125
17 372-BEL50-LTSWA-12 GUWN212 12 fibre multimode cable OM2 50/125
372-BEL50-LTSWA-24 GUWN224 24 fibre multimode cable OM2 50/125
Multimode 9/125 OS2 Loose Tube Indoor/Outdoor
18
372-BEL9-LTSWA-04 GUWN804 4 fibre single-mode cable OS2 9/125
372-BEL9-LTSWA-08 GUWN808 8 fibre single-mode cable OS2 9/125
19 372-BEL9-LTSWA-12 GUWN812 12 fibre single-mode cable OS2 9/125
372-BEL9-LTSWA-24 GUWN824 24 fibre single-mode cable OS2 9/125
20
6
Application
7
Central Loose Tube Cables for outdoor and indoor use in structured wiring systems, such as Industrial Backbone, Campus
Backbone, Building Backbone and/or Horizontal cabling. Suitable for direct burial, it is easy to install in ducts, tunnels and
trenches. These cables are Halogen-free (FRNC and LSNH). Black UV resistant outer jacket, multimode and single-mode: OM1, 8
OM2, 0S2 and ITU G.652D.
9
Specifications
• High mechanical and full rodent protection provided by • Crush resistance =/< 40KN/m 10
corrugated steel tape (CST) armour • Water tightness according to IEC60794-1-2-F5
• For outdoor use, suitable for direct burial • Temperature range: 11
• Water swellable E-glass yarns as strength members and Transport/storage: -30˚C to +70˚C
for the longitudinal water tightness Installation: -5˚C to +50˚C
• Corrugated Steel Tape Armouring: helical longitudinally 12
Operation: -30˚C to +70˚C
applied steel tape (0.155mm)
13
Anixter Number Vendor Number Description
Multimode 62.5/125 OM1 Loose Tube Outdoor
372-BEL62-LTACT-04 GUCB104 4 fibre multimode cable OM1 62/125 with LSNH jacket 14
372-BEL62-LTACT-06 GOCB106 6 fibre multimode OM2 62.5/125 with HDPE jacket
372-BEL62-LTACT-08 GOCB108 8 fibre mulitmode OM2 62.5/125 with HDPE jacket
15
372-BEL62-LTACT-12 GUCB112 12 fibre multimode cable OM1 62.5/125 with LSNH jacket
372-BEL62-LTACT-24 GUCB124 24 fibre multimode cable OM1 62.5/125 with LSNH jacket
Multimode 50/125 0M2 Loose Tube Outdoor 16
372-BEL50-LTACT-04 GUCB204 4 fibre multimode cable OM2 50/125 with LSNH jacket
372-BEL50-LTACT-06 GOCB206 6 fibre multimode cable OM2 50/125 with HDPE jacket
372-BEL50-LTACT-08 GUCB208 8 fibre multimode cable OM2 50/125 with LSNH jacket 17
372-BEL50-LTACT-12 GUCB212 12 fibre multimode cable OM2 50/125 with LSNH jacket
372-BEL50-LTACT-24 GUCB224 24 fibre multimode cable OM2 50/125 with LSNH jacket
18
Single-mode 9/125 0S2 Loose Tube Outdoor
372-BEL9-LTACT-04 GUCB804 4 fibre single-mode cable OS2 9/125 with LSNH jacket
372-BEL9-LTACT-08 GUCB808 8 fibre single-mode cable OS2 9/125 with LSNH jacket 19
372-BEL9-LTACT-12 GUCB812 12 fibre single-mode cable OS2 9/125 with LSNH jacket
372-BEL9-LTACT-24 GUCB824 24 fibre single-mode cable OS2 9/125 with LSNH jacket
20
Application
7
Brand-Rex armoured cables are designed for use where mechanical protection is required on offshore platforms, drilling rigs,
and onshore petrochemical plants. This range of cables can be exposed to fluids such as diesel, petrol, glycol, ethanol, white
8
spirit and ASTM oil 2. The resistance to these fluids is in accordance with DOD-STD-1678 method 8030.
9
Specification
10 • Fibre Type: 0.9mm tight buffered coded fibres • Armour: Galvanised steel wire braid armour
• Fibre Colours: Blue, orange, green, brown, grey, white, • Outer Sheath: Black halogen free weather
11 red, black, yellow, violet, pink, turquoise, blue/black, resistant material
orange/black, green/black, brown, black, grey/black, • Fire Characteristics: Flame retardant to IEC60332-3-24
white/black, red/black, brown(tan)/black, yellow/black, Category C
12 violet/black, pink/black, turquoise/black
• Inner Sheath: Flame retardant and halogen free
13 inner sheath
20
Application
7
i-MPC universal (indoor/outdoor tight buffered) cables can be employed both indoors and outdoors for campus backbone and
building backbone (riser) cabling, as well as for cabling between floor distributors and terminal equipment/workstations (fibre-
8
to-the-desk). The cables can be installed in conduits, ducts and be buried directly in the ground. The 900µm tight buffer
design allows a direct connection without need of a fan-out.
9
Specifications
10
• Tight buffer (TB) fibre of 900µm diameter, TB3 design Temperature Range:
(easy to strip) • Installation and assembly -5°C to +50°C
• Low smoke to IEC 61034 and EN 50268 zero halogen (LSZH) • Operation -20°C to +60°C 11
• Flame retardant to IEC 60332-3-24 and non-corrosive to • Transport and storage -25°C to +70°C
IEC 60754-2 (FRNC) 12
Multimode and single-mode in/out tight buffer with
• Metal free, hence no ground loop problems rodent protection
• Enhanced rodent protection Tight buffer cables multimode 62.5/125 (OM1), standard 13
• Completely dry design, water blocking to 50/125 (OM2), laser-optimised 50/125 (OM3) and single-
IEC 60794-1-2-F5 mode 9/125 (OS2), with LSZH jacket, dielectric glass yarn
• UV resistant armour, aramid yarns, central member with expandable 14
• Suitable for use outdoors and indoors yarns and ripcord.
• Especially suitable for field-installable UniCam® connectors 15
Anixter Number Vendor Number Description
373-COR625-TBDRP-06 LCXLM2M5006A700 6 fibre, multimode 62.5/125, black 16
373-COR625-TBDRP-12 LCXLM2M5012A700 12 fibre, multimode 62.5/125, black
373-COR625-TBDRP-24 LCXLM2M5024A700 24 fibre, multimode 62.5/125, black
17
373-COR50CC-TBDRP-06 LCXLM2L5006G700 6 fibre, multimode 50/125, black ClearCurve
373-COR50CC-TBDRP-12 LCXLM2L5012G700 12 fibre, multimode 50/125, black ClearCurve
373-COR50CC-TBDRP-24 LCXLM2L5024G700 24 fibre, multimode 50/125, black ClearCurve 18
373-COR300CC-TBD-06 LCXLM2L5006H700 6 fibre, 50/125 OM3 for 10Gig/sec applications, black ClearCurve
373-COR300CC-TBD-12 LCXLM2L5012H700 12 fibre, 50/125 OM3 for 10Gig/sec applications, black ClearCurve
373-COR300CC-TBD-24 LCXLM2L5024H700 24 fibre, 50/125 OM3 for 10Gig/sec applications, black ClearCurve 19
Application
7
Multi-fibre indoor cables are particularly suitable for placing and pulling into cable conduits and shafts (building backbone
and horizontal subsystems), also underfloor, for use as jumper and adapter cables and to connect workstations inside
8
buildings (fibre-to-the-desk). They can also be used as inter-building cables laid in dry conduits. The 900µm tight buffer
design allows easy and direct field installation.
9
Specifications
10
• Tight buffer fibre of 900µm diameter, TB3 design Temperature Range:
(easy to strip) • Installation and assembly -5°C to +50°C
11
• Low smoke to IEC 61034 and zero halogen (LSZH) • Operation -20°C to +60°C
• Flame retardant to IEC 60332-3C and EN 60332-3-24 • Transport and storage -25°C to +70°C
12 non-corrosive to IEC 60754-2 (FRNC)
Multimode and single-mode I-MIC indoor cable
• Metal free (no loop problems) Light and thin indoor cables, 900µm, TB3, LSZH
13 • Completely dry design multimode 62.5/125 (OM1), standard 50/125 (OM2) and
• Especially suitable for field-installable laser-optimised 50/125 (OM3) and single-mode 9/125 (OS2).
14 UniCam® connectors
15
16
17
18
19
20
374-COR300CC-TBD-02 LCXLI2L5002H700 2 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve
10
374-COR300CC-TBD-04 LCXLI2L5004H700 4 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve
374-COR300CC-TBD-06 LCXLI2L5006H700 6 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve 11
374-COR300CC-TBD-08 LCXLI2L5008H700 8 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve
374-COR300CC-TBD-12 LCXLI2L5012H700 12 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve 12
374-COR300CC-TBD-24 LCXLI2L5024H700 24 fibre, multimode 50/125 OM3 for 10 Gig/sec applications, aqua ClearCurve
16
17
18
19
20
Application
7
Cables can be employed for outdoor applications, for campus backbone and building backbone (riser) cabling mainly. The
cables can be buried directly in the ground or pulled into duct systems. Where high mechanical loads are involved, as is the
8
case in direct buried installations, the additional armouring is recommended. Metallic armouring is considered the most
effective protection against rodent damage. The metallic armouring is a corrugated steel tape under the outer jacket. A special
9 coating is used to bond the outer jacket to the steel tape. Where the mechanical loads are exceptionally high, a further inner
jacket can be inserted underneath the steel tape.
10
Specifications
11 • Central tube of loose tube construction, corrugated Steel • LSZH also satisfies standards for indoor cables IEC
Tape Armour (STA), PE or LSZH jacket 60332-1, IEC 60754-2 and IEC 61034 for non-corrosive,
• Test procedures to IEC 60794-1-2 for tensile strength, flame retardant and low smoke emission
12
impact resistance, crush resistance, bending features and • Multimode 50/125 (OM2), 62.5/125 (OM1) and single-
water penetration mode 9/125 (OS2)
13
Anixter Number Vendor Number Description
14 370-566-6AMPC-04 FWCT01S0004A004 4 fibre, multimode 62.5/125, STA, LSZH, black
370-566-6AMPC-06 FWCT01S0006A004 6 fibre, multimode 62.5/125, STA, LSZH, black
370-566-6AMPC-08 FWCT01S0008A004 8 fibre, multimode 62.5/125, STA, LSZH, black
15 370-566-6AMPC-12 FWCT01S0012A004 12 fibre, multimode 62.5/125, STA, LSZH, black
370-567-6AMPC-24 FWCT01S0024A004 24 fibre, multimode 62.5/125, STA, LSZH, black
16 373-COR50CC-LTACT-04 FWCT01S0004G004 4 fibre, multimode 50/125, STA, LSZH, black OM2, ClearCurve
373-COR50CC-LTACT-06 FWCT01S0006G004 6 fibre, multimode 50/125, STA, LSZH, black OM2, ClearCurve
373-COR50CC-LTACT-08 FWCT01S0008G004 8 fibre, multimode 50/125, STA, LSZH, black OM2, ClearCurve
17 373-COR50CC-LTACT-12 FWCT01S0012G004 12 fibre, multimode 50/125, STA, LSZH, black OM2, ClearCurve
373-COR50CC-LTACT-24 FWCT01S0024G004 24 fibre, multimode 50/125, STA, LSZH, black OM2, ClearCurve
18 370-568-6PE2-04 FWCT01S0004A003 4 fibre, multimode 62.5/125, STA, PE, black
370-568-6PE2-06 FWCT01S0006A003 6 fibre, multimode 62.5/125, STA, PE, black
19 370-568-6PE2-08 FWCT01S0008A003 8 fibre, multimode 62.5/125, STA, PE, black
370-568-6PE2-12 FWCT01S0012A003 12 fibre, multimode 62.5/125, STA, PE, black
Application
7
MPC universal cables can be employed both indoors and outdoors for campus backbone and building backbone (riser) cabling,
as well as for the cabling between floor distributors. The cables can be installed in conduits, ducts and be buried directly in
8
the ground.
9
Specifications
• Low smoke to IEC 61034 and EN 50268 zero halogen Temperature Range: 10
(LSZH) • Installation and assembly -5°C to +50°C
• Non-corrosive to IEC 60754-2 and EN 50267 • Operation -30°C to +70°C 11
• Flame retardant to IEC 60332-3-24 and EN 50266-2-4 • Transport and storage -40°C to +70°C
• Metal free, hence no ground loop problems Multimode and single-mode in/out mini-bundle with 12
• Enhanced rodent protection rodent protection
• Dry cable core Loose tube cables multimode 62.5/125 (OM1), 50/125
• Water blocking to IEC 60794-1-2-F5 (OM2) and laser-optimised 50/125 (OM3) and single-mode 13
• UV resistant 9/125 (OS2) with metal free central member, LSZH jacket,
• Suitable for use outdoors and indoors ripcord and an all-dielectric rodent protection (glass 14
yarn armour).
• Direct burial in the ground possible (microbe resistant)
15
Anixter Number Vendor Number Description
370-569-6RMPC-24 LCXLM1M4024A700 24 fibre (2 x 12), multimode 62.5/125, black 16
370-569-6RMPC-48 LCXLM1M4048A700 48 fibre (4 x 12), multimode 62.5/125, black
20
Application
7
MPC universal cables can be employed both indoors and outdoors for campus backbone and building backbone (riser) cabling,
as well as for cabling between floor distributors and terminal equipment/workstations (fibre-to-the-desk). The cables can be
8
installed in conduits, ducts and be buried directly in the ground.
9
Specifications
10 • Low smoke to IEC 61034 and EN 50268 zero Temperature Range:
halogen (LSZH) • Installation and assembly -5°C to +50°C
11 • Non-corrosive to IEC 60754-2 and EN 50267 • Operation -20°C to +60°C
• Flame retardant to IEC IEC 60332-3C and EN 60332-3-24 • Transport and storage -25°C to +70°C
• Metal free, hence no ground loop problems Multimode and single-mode in/out central tube with
12
• Enhanced rodent protection rodent protection
• Water blocking to IEC 60794-1-2-F5 Central tube construction cables multimode 62.5/125
13 • UV resistant (OM1), standard 50/125 (OM2) and laser-optimised 50/125
• Suitable for use outdoors and indoors (OM3) and single-mode 9/125 (OS2), all dielectric with flame
14 • Direct burial in the ground possible (microbe resistant) retardant LSZH jacket, rodent protection (glass yarn armour)
• Small diameter and ripcord.
16
17
18
19
20
6
373-COR50CC-LTDCT-04 LCXLM1K0004G700 4 fibre, multimode 50/125, black OM2, ClearCurve
373-COR50CC-LTDCT-06 LCXLM1K0006G700 6 fibre, multimode 50/125, black OM2, ClearCurve
373-COR50CC-LTDCT-08 LCXLM1K0008G700 8 fibre, multimode 50/125, black OM2, ClearCurve 7
373-COR50CC-LTDCT-12 LCXLM1K0012G700 12 fibre, multimode 50/125, black OM2, ClearCurve
373-COR50CC-LTDCT-16 LCXLM1K0016G700 16 fibre, multimode 50/125, black OM2, ClearCurve 8
373-COR50CC-LTDCT-24 LCXLM1K0024G700 24 fibre, multimode 50/125, black OM2, ClearCurve
9
373-COR300CC-LTCT-04 LCXLM1K0004H700 4 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve
373-COR300CC-LTCT-06 LCXLM1K0006H700 6 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve
373-COR300CC-LTCT-08 LCXLM1K0008H700 8 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve 10
373-COR300CC-LTCT-12 LCXLM1K0012H700 12 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve
373-COR300CC-LTCT-16 LCXLM1K0016H700 16 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve 11
373-COR300CC-LTCT-24 LCXLM1K0024H700 24 fibre, multimode 50/125 OM3 for 10Gig/sec applications, black ClearCurve
12
370-563-SMODE-04 LCXLM1D0004U700 4 fibre, single-mode 9/125, black
370-563-SMODE-06 LCXLM1D0006U700 6 fibre, single-mode 9/125, black
370-563-SMODE-08 LCXLM1D0008U700 8 fibre, single-mode 9/125, black 13
370-563-SMODE-12 LCXLM1D0012U700 12 fibre, single-mode 9/125, black
370-563-SMODE-24 LCXLM1D0024U700 24 fibre, single-mode 9/125, black 14
15
16
17
18
19
20
Application
7
Multimode indoor/outdoor fibre, tight buffered. Cable loss at 850nm 3.5 dB/km and at 1300nm 1.5 dB/km.
8
Specifications
9
• Outer Sheath: LSZH, UV stabilised for outdoor • Aramid yarn for added ‘crush’ protection to the
applications, black optical cores
10 • Sheath Thickness: 1.1mm • Available with OM1, OM2, OM3 and OM3e grade glass
• Fire Retardancy: 2 - 12 cores IEC 60332-1 and 60332- • Hybrid multimode and single-mode options available
11 3C, 16 - 24 cores IEC 60332-1
Application
7
TrueNet® loose tube, indoor/outdoor, LSZH duct grade cables.
8
Specifications
9
• Outer Sheath: LSZH, UV stabilised for outdoor • Fire Retardancy: 2 - 24 cores IEC 60332-1
applications, black • Glass fibre armour
• Water blocked (IEC60794) • Available with OM1, OM2, OM3 and OM3e grade glass 10
• Sheath Thickness: 1.5mm • Hybrid multimode and single-mode OS1 options available
11
Anixter Number Vendor Number Description
OM1 12
370-500-6LS2-04 7023 3 220-04 4 fibre 62.5/125µm
370-500-6LS2-08 7023 3 220-08 8 fibre 62.5/125µm
370-500-6LS2-12 7023 3 220-12 12 fibre 62.5/125µm 13
370-500-6LS2-16 7023 3 220-16 16 fibre 62.5/125µm
370-500-6LS2-24 7023 3 220-24 24 fibre 62.5/125µm
OM2
14
370-500-5LS2-04 7023 3 222-04 4 fibre 50/125µm
370-500-5LS2-08 7023 3 222-08 8 fibre 50/125µm 15
370-500-5LS2-12 7023 3 222-12 12 fibre 50/125µm
370-500-5LS2-16 7023 3 222-16 16 fibre 50/125µm
370-500-5LS2-24 7023 3 222-24 24 fibre 50/125µm 16
OM3
370-500-5LS20M3-04 7023 3 227-04 4 fibre 50/125µm
370-500-5LS20M3-08 7023 3 227-08 8 fibre 50/125µm 17
370-500-5LS20M3-12 7023 3 227-12 12 fibre 50/125µm
370-500-5LS20M3-16 7023 3 227-16 16 fibre 50/125µm
370-500-5LS20M3-24 7023 3 227-24 24 fibre 50/125µm 18
19
20
Application
7
Corning Cable Systems offers several tool kits for installation of UniCam® Connectors. The flagship tool kit is the UniCam®
High-Performance Tool Kit (TKT-UNICAM-PFC), a thoughtfully designed tool kit that virtually eliminates human variability
8
from installation.
The TKT-UNICAM-PFC includes a lightweight, hand-held installation tool with an immediate go/no-go feedback signal, providing
unmistakable confirmation of a successful termination. The kit’s high-performance cleaver has an integrated fibre scrap bin 9
and a dual-clamp precision hold for the field fibre, with a diamond blade to achieve a superior cleave. The UniCam®
High-Performance Tool Kit can be used with multimode or single-mode LC, SC and ST® Compatible UniCam® Connectors 10
(standard and High-Performance), and is required to achieve High-Performance specifications for UniCam® High-Performance
Single-mode Connectors.
11
The standard UniCam® Connector Installation Tool Kit (TKT-UNICAM) is a basic installation tool kit and can be used to terminate
all single- and 2-fibre UniCam® Connector styles (SC, LC, ST compatible, FC and MT-RJ connectors). UniCam® High-Performance
Multimode Connectors (SC, LC and ST compatible) can achieve High-Performance with the use of this tool. 12
The UniCam Connector Installation Tool Kit with Continuity Test Set (TKT-UNICAM-CTS-SF) provides a visual feedback feature
®
when terminating UniCam® SC, LC or ST Compatible Connectors. Useful for reducing scrap rates or for training new installers, 13
the TKT-UNICAM-CTS-SF is very popular, since the installer can watch for the red glow in the back of the connector to dim or
disappear. This indicates that the field fibre is inserted properly in the connector.
14
• UniCam® Connector installations
• Local area networks (LANs), including main cross-connect, 15
telecommunications room and telecommunications enclosures
• Fibre-to-the-desk
• Data centers
16
17
18
19
20
20
Application
7
The field-installable UniCam® connector versions provide a high quality alternative to epoxy and polish connectors. They
provide simple, quick and reliable connector installation on site. Fibre stubs are pre-installed in the ferrules of the UniCam®
8
connectors at the factory, thus eliminating the critical epoxy and polish operations in the field.
On site, the stripped and cleaved field fibres are inserted into the UniCam® connectors and retained. A mechanical
splice inside the connector establishes the low-loss connection between the field fibre and the pre-installed fibre inside 9
the connector.
The UniCam® connector can best be described as a mini pigtail. Unlike other no-epoxy, field-installable connectors, the 10
UniCam® connector requires no polishing.
• No-epoxy or polishing 11
• Economical cost for all fibre terminations
• Fastest termination time in the industry: less than 2 minutes per fibre 12
• Low labour and no consumables for reduced total cost
• Minimal tool kit, reduced set-up time; universal assembly tool terminates all single and 2-fibre UniCam® connector styles 13
• Small form factor options: LC and MT-RJ
• Eliminates unnecessary cable slack and storage
14
15
16
17
18
19
20
12 280092-NEW 95-050-99 UniCam® LC connector for multimode 50µm fibre (OM2), ceramic ferrule
280093-NEW 95-050-99-X UniCam® LC connector for multimode 50µm fibre (OM3), ceramic ferrule
13 280090-NEW 95-200-99 UniCam® LC connector for single-mode 9µm fibre (OS2), Ultra PC, ceramic ferrule
Accessories