General Catalogue: Piping Systems
General Catalogue: Piping Systems
General Catalogue: Piping Systems
Catalogue
Piping Systems
Table of Contents
About GF Hakan Plastik 4-5
About Plastics 6-7
Certification Details 8-9
Building Technology (BT) Range
• Silenta Extreme 10-15
Fire Resistant and Noise-insulated Halogen
Free Piping Systems
• Silenta Premium 16-23
Sound-Insulated Piping Systems
• Silenta 3A 24-29
Sound-Insulated Piping Systems
• Silenta FR Fire Resistant and 30-35
Sound-Insulated Piping Systems
• HT-PP Soil and Waste Piping Systems 36-41
• PVC-U Soil and Waste Piping Systems 42-49
• Rain Gutters and Fittings 50-53
• GF Aquasystem PP-R & PP-RCT Piping Systems 54-65
• PE-RT Piping Systems 66
• PE-XA Piping Systems 67
• PE-XB Piping Systems 68-69
• Hoses 70-73
• Building Technology (BT) Soil and Waste 76-79
Pipe Range Installation Instructions
• Building Technology (BT) Product Range 81-85
Installation Instructions
Utility (UT) Range
• Corrugated Piping Systems 88-91
• PVC-U Drainage Piping Systems 92-93
• Polyethylene Piping Systems 94-95
• PVC-U 96-97
Pressurized Potable Water Piping Systems
• PVC-U 98-99
Deep-Well Pipes and Fittings
• Utility Product Range 102-109
Installation Instructions
Packing, Stocking and Shipment
• Packaging 111
• Storage 112
• Transportation 113
Technical Tables
• Temperature, Pressure and Service Time Tables 115
• Chemical Resistance Tables 116-127
GF Hakan Plastik Boru ve Profil Sanayi ve Ticaret A.Ş. reserves its right to change the
technical values and images contained in this brochure without prior notice. It does not
assume any responsibilties arising from printing errors.
About Us
4
Founded in Switzerland in 1802, Georg Fischer Corporation operates in
3 main business lines: GF Piping Systems, GF Casting Solutions and GF
Machining Solutions. Georg Fischer is present in 34 countries with 57
production plants and 136 companies.
Benefits of Plastics
Plastics are polymers created by the chemical Thermoplastics in turn can be split into two main categories as
conversion of natural products or synthesized partially-regulated (semi-crystalline) and iregular (amorphous)
from organic materials. The primary components molecular structures.
that make up the building blocks of plastics are
long chains of carbon (C) and hydrogen (H) known • Semi
crystalline thermoplastics, which have a partially
as monomers. ordered molecular structure: this category includes the
polyolefins (polypropylene, polyethylene, polybutylene) and
The raw materials used for the production of plastics are fluoropolymers (PVDF, PTFE, etc.)
natural compounds such as cellulose, coal, oil and natural • Amorphous thermoplastics, which have no crystalline
gas. In the plastics industry, around 6 % of the petroleum regions and no packed molecular structure: this category
products that come out from refineries is used. includes the vinyl chlorides (PVC-U, PVC-C, etc.) and styrenes
(ABS, polystyrene, etc.]
Plastics fall into three main categories on the basis of their
internal structure and the resulting mechanical characteris Semicrystalline materials are more suitable for hot
tics: thermoplastics, thermosetting plastics and elastomers. welding, while amorphous thermoplastics are ideal for
cementing or cold welding (solvent cementing).
6
Advantages of Plastics
Thermoplastics obviously demonstrate different characteristics than those of the metals traditionally used
for piping.
Metal Systems Plastic Systems
High density Low density
* Crane needed for transport * Can be carried by hand up to d110
* Widely spaced fixings * Closely spaced fixings
* High anchoring forces, fixing required * Limited anchoring forces, simple and economic
The following graphics indicate the assessment of the lifetime According to the main results of the study, plastic piping
of thermoplastic piping systems in terms of the quality of their systems demonstrate better performance than metal systems.
environmental perfomance and application of them in building This finding has been confirmed by other studies conducted in
technology, industry and water and gas distribution. In the this field.
analysis, the impacts of one meter long pipe was compared
with the main competitor materials (DN25, DN80, DN150 and The main reason for high performance of thermoplastics is
DN400) for each of the commonly used plastics. GF supplied that they are lightweight. This ensures key benefits during
this analysis from an independent, Swiss-based organization transport and installation. Fully-plastic solutions are lighter
specialized in environmental performance analyzes, and is than other piping systems of conventional materials, and this
based on Ecoinvent, leading lifecycle inventory database in creates significant impacts on carbon footprint.
the world.
Disposal
İmha
Transport
Nakliye
25.0 Production of Pipes
Boruların Üretimi
Production of Raw Üretimi
Hammaddelerin Materials
20.0
2 eşdeğer
15.0
Kilogram equivalent
COCO
10.0
Kilogram
5.0
PVC-U
PVC-C
PP
PB
PE 100
ABS
0.0
PVDF
steel
steel
Coatedçelik
steel
çelik
çelik
Copper
Galvanized
Bakır
Kaplanmamış
Stainless
Galvenizli
Paslanmaz
Quality
Certificates
8
Manufacturing its products in accordance with
the European standards and Turkish standards Presenting its product standards in a way that offers the
equivalent to the European standards, our quality and continuity required for customers, GF Hakan
Company is a leading and dynamic organization Plastik exports its products to over 70 countries based on
in terms of continous improvement and customer these certificates.
satisfaction.
In addition to product quality, the process and system quality of
Some of the product quality certificates of our GF Hakan Plastik is certified by BVQI through TS EN ISO 9001:2015
Company are as follows: certificate and the company maintains its efforts on certification.
Our Company that places top priority on process and system
DVGW (Germany) - SKZ (Germany) - Hygiene Institute (Germany) quality also has TS EN ISO 14001:2015 and TS EN ISO 45001:2018
- Fraunhofer (Germany) - Nordic Polymark (Sweden) - AENOR certificates. Our both two production plants in Çerkezköy and
(Spain) - UkrSepro (Ukraine) - GOST (Russia) - SABS (South Şanlıurfa have TS EN ISO/IEC 17025:2017 laboratory accreditation
Africa) - TSE (Turkey) certificates awarded by TÜRKAK organization.
Certificates
RUSSIA-BELARUS
SPAIN GERMANY SWITZERLAND KAZAKHSTAN-
AFITI LICOF DIN CERTCO SGS KYRYGYZSTAN
ARMENIA
TURKEY
MALAYSIA GERMANY
YILDIZ TECHNICAL GERMANY
IKRAM QA DVGV
UNIVERSITY REPORT DIBT
Due to its halogen-free feature, it does not emit any poisonous and lethal gases in case of fire.
It is manufactured with the last generation of multilayer polypropylene technology according to the
requirements of EN 1451, EN 13501 and DIN EN 14366 standards.
Fields of Application
• All soil and waste water drainage systems inside the buildings • Rainwater systems
• Office buildings, conference halls etc. • Sustainable / green buildings
• Schools, libraries, hospitals, hotels, houses • Industrial areas (short and long-term use)
• All underground drainage systems between the building
and the main pipeline
Fire Classification:
Halogen (acc. to EN 13501-1) B-s1, d0
Free PP B : Hardly Combustible
s1 : No Smoke formation
d0 : No Burning Droplets formation
18 dB(A)
10
Structure
Internal Layer (PP)
[Flame Retardant Reinforced Composite]
It provides a perfect flow performance with its
1 smooth inner surface and anti-fouling structure.
The superior chemical resistance prevents
corrosion and abrasion. It is resistant to high
water temperatures (up to 97 °C). Fire Resistant.
The emitted noise level at 4l/s flow rate, with special GF Hakan Silent clamps, is only
18 dB(A) according to DIN EN 14366.
SILENTA EXTREME
ACOUSTIC PERFORMANCE dB(A)
17 18 dB(A)
dB(A)
11 12 dB(A)
dB(A)
0,5 l/s
1 l/s
Water flow (l/s) 2 l/s
4 l/s
12
Silenta Extreme
Silenta Extreme Branch 45° Silenta Extreme Corner Double Branch 87,5°
14
Silenta Extreme
• Silenta Premium Sound-Insulated Pipe Systems providing • Provides excellent sound insulation, creates ideal conditions
a complete solution with advanced level durability, impact for buildings and contributes to an increase in the property value
resistance, low sound level and easy installation features have along with the quality of life. Reduces the vibrations and unfamiliar
considerably wide product range sounds coming from the plumbing system
• It reached 13 dB(A) sound intensity level at the flow rate of 4 l/s in • It is suitable for hot/cold water and acidic liquid transfers.
the tests conducted by the German Fraunhofer Institute according • No corrosion, durable
to EN 14366 • Alternative to cast iron pipes
• It can be used in the underground and aboveground drainage • Does not contain halogen and emit lethal and poisonous gases
systems even in the areas having high traffic load • 100% recyclable and environmentally friendly
Fields of Application
• Office buildings, conference halls etc
• Schools, libraries, hospitals, hotels, houses
• All underground drainage systems between the building and the
main pipeline
• Sustainable / green buildings
• Industrial areas (short and long-term use)
13 dB(A)
16
STRUCTURE
Inner Layer
It provides a perfect flow performance
1 with its structure. The superior chemical
resistance prevents corrosion and abrasion.
It is resistant to high water temperatures.
Middle Layer
2 With its high molecular structure and
special composite formula, the sound waves
are absorbed and prevented.
3 Outer Layer
It is resistant to high temperatures and
impacts.
Special Gasket System
It guarantees water tightness with its special
4 gasket structure providing ease of montage.
The geometrical properties of the gasket
groove ensure fast and easy installation.
Technical Properties
Pipe Structure 3-Layered (Special PP-Mineral reinforced composite)
Diameters [mm] d58, d78, d90, d110, d135, d160, d200
Pipe length [mm] 150, 250, 500, 1000, 2000, 3000
Sound transmission 13 dB(A) at 4 l/s (EN 14366)
Fire class B2 (DIN 4102)
Jointing method Jointing with Rubber Gasket and Socket (Push-Fit)
Clamping With GF Hakan Silent pipe clamps
Color Light Grey (Halogen-free and Cadmium-free)
Installation Very easy to install thanks to its weight lower than cast-iron pipes
Thermal expansion coefficient 0.04 mm/moK
Tensile strength 13 N/mm2
Chemical resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation temperature Minimum: -10oC Maximum: 60oC
Operating temperature Minimum: -10oC Maximum: 97oC
Application class B/D (building / drainage)
Ring Stifness ISO/DIN 9969, The ring stiffness is at least 4.0 kN / m2 over the entire range of – dimensions: 58 mm – 200 mm
Impact strength Complies with EN 1451
Approvals and Certificates Germany: DIBt, Fraunhofer, Hoch, Ukraine: Sepro, Russia: Gost, Malaysia: Ikram, Turkey: TSE
Superior Sound-Proof
Performance
Sound-insulated soil and waste water pipe system Silenta Premium guarantees
quality, peace of mind and living comfort.
The emitted noise level at 4l/s flow rate, with special GF Hakan Silent clamps, is
only 13 dB(A) according to DIN EN 14366.
SILENTA PREMIUM
ACOUSTIC PERFORMANCE dB(A)
13 dB(A)
7 dB(A)
7 dB(A)
4 dB(A)
0,5 l/s
1 l/s
Water flow (l/s) 2 l/s
4 l/s
18
Silenta Premium
90 4501109000521 Cartonbox 32
Dia. Leng. Thick. Code Packing 110 4501111000821 Cartonbox 16
[mm] [mm] [mm] Type Pc
20
Silenta Premium
58 4501505803021 Cartonbox 25
Dia. Code Packing
78 4501507803121 Cartonbox 15 (mm) Type Pc
90 4501509003121 Cartonbox 45
58 4501305800421 Cartonbox 50
110 4501511003221 Cartonbox 36
78 4501307800521 Cartonbox 28
135 4501513503321 Cartonbox 20
90 4501309000121 Cartonbox 12
160 4501516003421 Cartonbox 6
200 4501520003521 Cartonbox 4
22
Silenta Premium
50 1300905030412 Cartonbox 20
58 1300905830412 Cartonbox 20
75-78 1300907530412 Cartonbox 15
110 1300911030412 Cartonbox 10
135 1300913530412 Cartonbox 10
160 1300916030412 Cartonbox 7
Silenta Premium Floor Trap - Long 200 1300920030412 Cartonbox 5
Dia. Code Packing
(mm) Type Pc
50 1300905030612 Cartonbox 50
58 1300905830612 Cartonbox 30
Silenta Premium P - Trap 75-78 1300907530612 Cartonbox 30
Dia. Code Packing 110 1300911030612 Cartonbox 25
(mm) Type Pc 135 1300913530612 Cartonbox 25
110 4501611000521 Cartonbox 15 160 1300916030612 Cartonbox 25
200 1300920030612 Cartonbox 20
Fields of Application
• Office buildings, conference halls etc
• Schools, libraries, hospitals, hotels, houses
• All underground drainage systems between the building and the
main pipeline
• Sustainable / green buildings
• Industrial areas (short and long-term use)
16 dB(A)
24
Structure
1 Inner Layer
It provides a perfect flow performance with its
structure. The superior chemical resistance
prevents corrosion and abrasion. It is resistant
to high water temperatures.
2 Middle Layer
With its high molecular structure and special
composite formula, the sound waves are
absorbed and prevented.
3 Outer Layer
It is resistant to high temperatures and impacts.
Technical Properties
Pipe Structure 3-Layered (Special PP-Mineral reinforced composite)
Diameters [mm] d40, d50, d75, d110, d125, d160, d200
Pipe length [mm] 150, 250, 500, 1000, 2000, 3000
Sound transmission 16 dB(A) at 4 l/s (TS EN 14366)
Fire class B2 (DIN 4102)
Jointing method Jointing with Rubber Gasket and Socket (Push-Fit)
Clamping With GF Hakan Plastic silent pipe clamps
Color Light Blue (Halogen-free and Cadmium-free)
Installation Very easy to install thanks to its weight lower than cast-iron pipes
Thermal expansion coefficient 0.06 mm/moK
Tensile strength 13 N/mm2
Chemical resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation temperature Minimum: -10oC Maximum: 60oC
Operating temperature Minimum: -10oC Maximum: 97oC
Application class B/D (building / drainage)
Ring Stifness ISO/DIN 9969, The ring stiffness is at least 4.0 kN / m2 over the entire range of – dimensions: 40 mm – 200 mm
Impact strength Complies with EN 1451
Approvals and Certificates Germany: Fraunhofer, Hoch, Spain: AENOR, Sweden: Kiwa/SwedCert,
Ukraine: Sepro, Russia: Gost, UK: LR Lloyd Register, Malaysia: Ikram, Turkey: TSE
Superior Sound Proof
Performance
Sound-insulated soil and waste piping system Silenta 3A
guarantees quality, peace of mind and living comfort.
SILENTA 3A
ACOUSTIC PERFORMANCE dB(A)
9 dB(A)
8 dB(A)
7 dB(A)
0,5 l/s
1 l/s
2 l/s
Water flow (l/s) 4 l/s
26
Silenta 3A
50 4704505000121 Cartonbox 50
75 4704507500221 Cartonbox 20
110 4704511000321 Cartonbox 10
160 4704516000421 Cartonbox 6
200 4704520000521 Cartonbox 12
Silenta 3A Branch 67,5°
50 4704505000221 Cartonbox 50
Silenta 3A Branch 87,5°
75 4704507500321 Cartonbox 35
Dia. Code Packing 110 4704511000421 Cartonbox 8
(mm) Type Pc 160 4704516000621 Cartonbox 6
50-50 4704205001821 Cartonbox 30 200 4704520000721 Cartonbox 4
75-50 4704207501921 Cartonbox 10
75-75 4704207502021 Cartonbox 15
110-50 4704211002121 Cartonbox 50
110-75 4704211002221 Cartonbox 15
110-110 4704211002321 Cartonbox 10
125-110 4704212503822 Cartonbox 20 Silenta 3A Pipe Socket Plug
125-125 4704212503921 Cartonbox 4
160-125 4704216004022 Cartonbox 10 Dia. Code Packing
(mm) Type Pc
Silenta 3A P-Trap
Dia. Code Packing
(mm) Type Pc
• Silenta FR Fire Resistant Sound-Insulated Piping System • High-quality gaskets are used
reached 12 dB(A) sound intensity level at the flow rate of 4 • Smooth inner and outer surface ensures ease of installation
l/s in the tests conducted by the German Fraunhofer Institute • No clogging because it does not create residues and lime
according to EN 14366 • Ensures fast and smooth flow in the system
• Its fire class value is B-s1, d0 according to TS EN 13501-1 • Resistant to corrosion
• Produced by mineral additive special formulation • 100% recyclable and environmentally friendly
• Made of PVC-U composite material in single layer. This composite
layer increases the strength and chemical and physical resistance
of pipes and fittings
Fields of Application
• Office buildings, conference halls etc
•Schools, libraries, hospitals, hotels, houses
• All underground drainage systems between the building
and the main pipeline
• Sustainable / green buildings
• Industrial areas (short and long-term use)
B-s1, d0
Fire Classifaction
(acc. to EN 13501-1)
B : Hardly Combustible
12 dB(A)
s1 : No Smoke formation
d0 : No Burning Droplets formation
30
Structure
Special Gasket System
1 It guarantees water tightness with its special
gasket structure providing ease of montage.
The geometrical properties of the gasket groove
ensure fast and easy installation.
2 Inner Surface
It ensures superior flow performance with its
smooth structure. Thanks to chemical durability,
it prevents corrosion that occurs in pipe.
Outer Surface
3 Resistant against impacts and fire. Prevents the
spread of fire thanks to its special composite
fire-retarding formulation.
Technical Properties
Pipe Structure One Layered (Special PVC composite formulation with fire-retardent and sound absorbing additives)
Diameters [mm] d50, d75, d110, d125, d160, d200, d250
Pipe Length [mm] 150, 250, 500, 1000, 2000, 3000
Sound Transmission 12 dB(A) at 4 l/s (EN 14366)
Fire class B1 (DIN 4102), B-s1, d0 (TS EN 13501)
Jointing method Jointing with Rubber Gasket and Socket (Push-Fit)
Clamping With GF Hakan Silent pipe clamps
Color Light Grey
Installation Very easy to install thanks to its weight lower than cast-iron pipes
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: -10oC Maximum: 60oC
Operating Temperature Minimum: -10oC Maximum: 60oC
Application Class B/D (building / drainage)
Ring Stifness ISO/DIN 9969, The ring stiffness is at least 4.0 kN / m2 over the entire range of – dimensions: 50 mm – 250 mm
Impact Strength Compiles with EN 1451
Approvals and Certificates Germany: Fraunhofer, Turkey: TSE
Superior Sound-Proof And
Non-Flammable Performance
Silenta FR Fire Resistant and Sound-Insulated Pipes
guarantee quality, peace of mind and living comfort.
12
performance tests were conducted in compliance with the
standard DIN EN 14366. dB(A)
The emitted noise level at 4l/s flow rate, with special GF Hakan
Silent clamps, is only 12 dB(A) according to DIN EN 14366.
SILENTA FR
ACOUSTIC PERFORMANCE dB(A)
7 dB(A)
7 dB(A)
4 dB(A)
0,5 l/s
1 l/s
2 l/s
Water flow (l/s) 4 l/s
32
Silenta FR
50
1300905030412 Cartonbox 20
75
1300907530412 Cartonbox 15
110
1300911030412 Cartonbox 10
125
1300912530412 Cartonbox 10
200
1300920030412 Cartonbox 5
50 1300905030612 Cartonbox 50
75 1300907530612 Cartonbox 30
110 1300911030612 Cartonbox 25
125 1300912530612 Cartonbox 25
160 1300916030612 Cartonbox 25
200 1300920030612 Cartonbox 20
75 1300507520311 Cartonbox 90
125 1300512520511 Cartonbox 30
160 1300516020611 Cartonbox 2
34
What is Sound Insulation
Performance?
Sound insulation performance is the sound insulation capability of the system against the vibrations that occur between the pipes used
in the waste water installation and the fluids transmitted through these pipes. With Silenta Premium, Silenta 3A and Silenta FR Piping
Systems, GF Hakan Plastik offers ultimate solutions against the sounds created in the installations.
8
Sound Performance dB(A)
0
0,5 1 2 4
Fields of Application
• Office buildings, conference halls etc
• Schools, libraries, hospitals, hotels, houses
• All underground drainage systems betweenthe building and the main pipeline
• Sustainable / green buildings
• Industrial areas (short and long-term use)
36
Structure
2 Inner Surface
It provides a perfect flow performance with its
structure. The superior chemical resistance
prevents corrosion and abrasion. It is resistant
to high water temperatures.
3 Outer Surface
Resistant against impacts and high
temperatures.
Technical Properties
Pipe Structure One Layered Solid Structure
Diameters [mm] d32, d40, d50, d75, d110, d125, d160, d200
Pipe Length [mm] 150, 250, 500, 1000, 2000, 3000
Fire class B2 (DIN 4102)
Jointing method Jointing with Rubber Gasket and Socket (Push-Fit)
Clamping With GF Hakan Standard Pipe Clamps
Color Dark Grey and Orange
Installation Very easy to install thanks to its weight lower than cast-iron pipes
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: -10oC Maximum: 60oC
Operating Temperature Minimum: -10oC Maximum: 97oC
Application Class B/D (building / drainage)
Impact Strength Complies with EN 1451
Ring Stifness ISO/DIN 9969, The ring stiffness is at least 4.0 kN / m2 over the entire range of – dimensions: 32 mm – 200 mm
Approvals and Certificates Germany: Hoch, Sweden: Insta-Cert, Ukraine: Sepro, Russia: Gost-R, Turkey: TSE
HT-PP
HT-PP Pipe with Socket (S 20) HT-PP Pipe with Double Socket (S 20)
38
HT-PP
75 4901507592521 Cartonbox 30
75 4901307530921 Cartonbox 80
Fields of Application
• Office buildings, conference halls etc
• Schools, libraries, hospitals, hotels, houses
• All underground drainage systems between the building and the main pipeline
• Sustainable / green buildings
• Industrial areas (short and long-term use)
Fire Classifaction
(acc. to EN 13501-1) B-s2, d0
B : Hardly Combustible
s2 : Minimum Smoke formation
d0 : No Burning Droplets formation
B-s2, d0
42
Structure
Special Gasket System
1 The push-fit socket with lip seal
guarantees water tightness and allows
movement of the pipe due to thermal expansion.
The geometric characteristics of the socket
ensure installation speed and simplicity.
2 Inner Surface
It provides a perfect flow performance with its
structure. The superior chemical resistance
prevents corrosion and abrasion. It is resistant
to high water temperatures.
Outer Surface
3 Resistant against impacts and fire. Prevents
the spread of fire, thanks to its special Flame
Retarding composite structure.
Technical Properties
Pipe Structure One Layered (Special PVC composite formulation with fire-retarding additives)
Diameters [mm] d50, d75, d110, d125, d160, d200, d250
Pipe Length [mm] 150, 250, 500, 1000, 2000, 3000
Fire class B1 (DIN 4102), B-s2, d0 (EN 13501-1)
Jointing method Jointing with Rubber Gasket and Socket (Push-Fit)
Clamping With GF Hakan Standard Clamps
Color Light Grey
Installation Very easy to install thanks to its weight lower than cast-iron pipes
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: -10oC Maximum: +60oC
Operating Temperature Minimum: -10oC Maximum: +60oC
Application Class B/D (building / drainage)
Standart EN 1329-1
Ring Stifness ISO/DIN 9969, The ring stiffness is at least 4.0 kN / m2 over the entire range of – dimensions: 50 mm – 250 mm
Approvals and Certificates Sweden: Insta- Cert, Ukraine: Sepro, Turkey: TSE
PVC Soil and Waste Water Pipes
PVC Waste Water Pipe Light Grey PVC Waste Water Pipe Orange
Dia. Leng. Thick. Color Code Packing Dia. Leng. Thick. SN Color Code Packing
(mm) (mm) (mm) Type Pc (mm) (mm) (mm) Type Pc
50 150 3,0 Light Grey 1000005000111 Bag 100 110 500 3,2 SN4 Orange 1008011004311 Bundle 10
50 250 3,0 Light Grey 1000005000211 Bag 70 110 1000 3,2 SN4 Orange 1008011004411 Bundle 4
50 500 3,0 Light Grey 1000005000311 Bag 30 110 2000 3,2 SN4 Orange 1008011004511 Bundle 4
50 1000 3,0 Light Grey 1000005000411 Bundle 10 110 3000 3,2 SN4 Orange 1008011004611 Bundle 4
50 2000 3,0 Light Grey 1000005000511 Bundle 10 110 6000 3,2 SN4 Orange 1008011004811 Length 1
50 3000 3,0 Light Grey 1000005000611 Bundle 10 110 500 3,2 SN8 Orange 1008011015011 Bundle 10
50 6000 3,0 Light Grey 1000005000711 Bundle 5 110 1000 3,2 SN8 Orange 1008011015111 Bundle 4
75 150 3,0 Light Grey 1000007502111 Bag 30 100 2000 3,2 SN8 Orange 1008011015211 Bundle 4
75 250 3,0 Light Grey 1000007502211 Bag 40 110 3000 3,2 SN8 Orange 1008011015311 Bundle 4
75 500 3,0 Light Grey 1000007502311 Bag 20 110 6000 3,2 SN8 Orange 1008011015411 Length 1
75 1000 3,0 Light Grey 1000007502411 Bundle 10 125 500 3,2 SN4 Orange 1008012510011 Bundle 8
75 2000 3,0 Light Grey 1000007502511 Bundle 10 125 1000 3,2 SN4 Orange 1008012510111 Bundle 5
75 3000 3,0 Light Grey 1000007502611 Bundle 5 125 2000 3,2 SN4 Orange 1008012510211 Bundle 5
75 6000 3,0 Light Grey 1000007502711 Length 1 125 3000 3,2 SN4 Orange 1008012510311 Bundle 3
110 150 3,2 Light Grey 1000011004111 Bag 30 125 6000 3,2 SN4 Orange 1008012510411 Length 1
110 250 3,2 Light Grey 1000011004211 Bag 20 125 500 3,7 SN8 Orange 1008012511011 Bag 8
110 500 3,2 Light Grey 1000011004311 Bag 10 125 1000 3,7 SN8 Orange 1008012511111 Bundle 5
110 1000 3,2 Light Grey 1000011004411 Bundle 4 125 2000 3,7 SN8 Orange 1008012511211 Bundle 5
110 2000 3,2 Light Grey 1000011004511 Bundle 4 125 3000 3,7 SN8 Orange 1008012511311 Bundle 5
110 3000 3,2 Light Grey 1000011004611 Bundle 4 125 6000 3,7 SN8 Orange 1008012511411 Length 1
110 6000 3,2 Light Grey 1000011004711 Length 1 160 500 4 SN4 Orange 1008016025011 Bundle 4
125 150 3,2 Light Grey 1000012506111 Bag 20 160 1000 4 SN4 Orange 1008016025111 Bundle 3
125 250 3,2 Light Grey 1000012506211 Bag 15 160 2000 4 SN4 Orange 1008016025211 Bundle 6
125 500 3,2 Light Grey 1000012506311 Bag 8 160 3000 4 SN4 Orange 1008016025311 Bundle 3
125 1000 3,2 Light Grey 1000012506411 Bundle 5 160 6000 4 SN4 Orange 1008016025411 Length 1
125 2000 3,2 Light Grey 1000012506511 Bundle 5 160 500 4,7 SN8 Orange 1008016030111 Bundle 4
125 3000 3,2 Light Grey 1000012506611 Bundle 3 160 1000 4,7 SN8 Orange 1008016030211 Bundle 3
125 6000 3,2 Light Grey 1000012506711 Length 1 160 2000 4,7 SN8 Orange 1008016030311 Bundle 3
160 150 4,0 Light Grey 1000016008111 Bag 12 160 3000 4,7 SN8 Orange 1008016030411 Bundle 3
160 250 4,0 Light Grey 1000016008211 Bag 8 160 6000 4,7 SN8 Orange 1008016031511 Length 1
160 500 4,0 Light Grey 1000016008311 Bag 4 200 1000 4,9 SN4 Orange 1008020035111 Bundle 3
160 1000 4,0 Light Grey 1000016008411 Bundle 3 200 2000 4,9 SN4 Orange 1008020035211 Length 1
160 2000 4,0 Light Grey 1000016008511 Bundle 3 200 3000 4,9 SN4 Orange 1008020035311 Length 1
160 3000 4,0 Light Grey 1000016008611 Bundle 3 200 6000 4,9 SN4 Orange 1008020035411 Length 1
160 6000 4,0 Light Grey 1000016008711 Length 1 200 1000 5,9 SN8 Orange 1008020040111 Bundle 3
200 500 4,9 Light Grey 1000020010311 Bundle 6 200 2000 5,9 SN8 Orange 1008020040211 Length 1
200 1000 4,9 Light Grey 1000020010411 Bundle 3 200 3000 5,9 SN8 Orange 1008020040311 Length 1
200 2000 4,9 Light Grey 1000020010511 Length 1 200 6000 5,9 SN8 Orange 1008020041011 Length 1
200 3000 4,9 Light Grey 1000020010611 Length 1 250 1000 6,2 SN4 Orange 1008025012411 Length 1
200 6000 4,9 Light Grey 1000020010711 Length 1 250 2000 6,2 SN4 Orange 1008025012511 Length 1
250 500 6,2 Light Grey 1000025012311 Bundle 6 250 3000 6,2 SN4 Orange 1008025012611 Length 1
250 1000 6,2 Light Grey 1000025012411 Length 1 250 6000 6,2 SN4 Orange 1008025020511 Length 1
250 2000 6,2 Light Grey 1000025012511 Length 1 250 1000 7,3 SN8 Orange 1008025050011 Length 1
250 3000 6,2 Light Grey 1000025012611 Length 1 250 2000 7,3 SN8 Orange 1008025050111 Length 1
250 6000 6,2 Light Grey 1000025012711 Length 1 250 3000 7,3 SN8 Orange 1008025050211 Length 1
250 6000 7,3 SN8 Orange 1008025050311 Length 1
315 1000 7,7 SN4 Orange 1008031514011 Length 1
315 2000 7,7 SN4 Orange 1008031514111 Length 1
315 3000 7,7 SN4 Orange 1008031514211 Length 1
315 6000 7,7 SN4 Orange 1008031520611 Length 1
315 1000 9,2 SN8 Orange 1008031520011 Length 1
315 2000 9,2 SN8 Orange 1008031520111 Length 1
315 3000 9,2 SN8 Orange 1008031520211 Length 1
315 6000 9,2 SN8 Orange 1008031520311 Length 1
44
PVC Soil and Waste Water Fittings
200-110 Light Grey 1300220009512 Bag 5 50 Light Grey 1300105000411 Bag 150
200-160 Light Grey 1300220009712 Bag 5 110 Light Grey 1300111001711 Bag 25
200-200 Light Grey 1300220009812 Bag 4 125 Light Grey 1300112501911 Bag 20
250-110 Light Grey 1300220009912 Bag 3 160 Light Grey 1300116002411 Bag 10
250-125 Light Grey 1300225010012 Bag 1 200 Light Grey 1300120002611 Bag 5
250-160 Light Grey 1300225010112 Bag 1 250 Light Grey 1300125002612 Bag 2
46
PVC Soil and Waste Water Fittings
PVC Reducer
50 1300905023312 Cartonbox 20
75 1300907523412 Cartonbox 16
PVC Clamp
PVC Repair Pipe (Type 1) (Long Socket)
Dia. Code Packing
(mm) Type Pc
Dia. Code Packing
50 1300905024012 Cartonbox 100 (mm) Type Pc
75 1300907524112 Cartonbox 300
110 1000011030111 Bag 20
110 1300911024212 Cartonbox 150
75 1300907530082 Cartonbox 30
Technical Properties
Structure One Layered
Diameters [mm] 150 mm rectangular
Gutter Length [mm] 150, 250, 500, 1000, 2000, 3000, 4000
Jointing method Sealed
Clamping With GF Hakan Rain gutter clamps
Color Light Grey and Brown
Installation Very easy installation as it is lightweight
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: -10oC Maximum: +60oC
Operating Temperature Minimum: -10oC Maximum: +60oC
Approvals and Certificates Turkey: TSE
50
Rain Gutters
Cornered Elbow
Rectangular Socket
Profile Pipe Passage Part -Without Socket Rectangular Rain Gutter -Brown
Profile Socket
52
Rain Gutters
Elbow 87°
75 1309107500711 Bag 75
Down Socket (Round)
PP-RCT is a new generation raw material which is developed for polypropylene by using a special
β-nucleation process.
Thanks to this enchancement, GF Aquasystem withstand higher
operating pressures at extreme temperatures, higher flow rates
and resistance to chlorine.
- PP-RCT Glass-Fiber Reinforced Piping Systems :
• SDR9 - PN22
• SDR7,4 - PN25
Fields of Application
• Central heating systems
• Hot and cold water systems
• Drinking water and treated water supply systems
• Industrial Piping Systems (Transfer and discharge of
chemicals)
• Air conditioner systems
• Solar Collectors
54
Standard PP-R Pipes Glass Fiber Reinforced Composite PP-R Pipe
External Aluminum Foil Composite PP-R Pipe Middle Aluminum Foil Composite PP-R Pipe
Technical Properties
Pipe Structure One Layer-Standard Pipes
Multi-Layer: Glass Fiber Reinforced Composite Pipes/Aluminum Foil Composite Pipes
Diameters [mm] d20, d25, d32, d40, d50, d63, d75, d90, d110, d125, d160, d200
Pressure Classes: Standard PPR Pipes PN10 (SDR11), PN16 (SDR7.4), PN20 (SDR6)
Glass Fiber Reinforced Composite Pipes: PN10 (SDR11), PN20 (SDR7.4), PN25 (SDR6)
External Aluminum Foil Composite Pipes: PN25 (SDR6)
Middle Aluminum Foil Composite Pipes: PN20 (SDR6)
PP-RCT Glass Fiber Reinforced Pipes (SDR9: PN22 – SDR7,4: PN25)
Pipe Length [mm] 4000 mm
Jointing Methods Socket Fusion Welding, Butt-Welding, Electrofusion Welding, Mechanical Connection,
Flange Connection
Color White, Green, Grey (For grey colour codes, please contact to GF Hakan Sales Department)
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: +5oC Maximum: +40oC
Operating Temperature Standard PPR Pipes: +5oC - +70oC
Glass Fiber Reinforced Composite Pipes: +5oC - +95oC
Aluminum Foil Composite Pipes: +5oC - +95oC
Application Class B (Building)
Standards EN15874-1/2/3, DIN 8077-78
Thermal Expansion Coefficient Standard Pipes: 0.15 mm/moK
Glass Fiber Reinforced Composite Pipes: 0.035 mm/moK
Aluminum Foil Composite Pipes: 0.030 mm/moK
Thermal Conductivity Coefficient 0.24 W/moK
Approvals and Certificates Spain: AENOR, UK: WRAS, LLYOD’s, Germany: DVGW, SKZ, HYGIENE,
Turkey: TSE, Ukraine: HYGIENE, SEPRO, Russia: GOST, HYGIENE, Bulgaria: BULGARKONTROLA
PP-R Aquasystem
PP-R Standard Pipe - PN10 (SDR11) PP-R Glass Fiber Reinforced Climafaser Pipe - PN10
(SDR 11)
Dia. Thic. Code - White Code - Green Packing
(mm) (mm) Type Pc Dia. Thic. Code - Green Packing
20 1,9 4000002002021 4002002002021 Bundle 100 (mm) (mm) Type Pc
25 2,3 4000002502121 4002002502121 Bundle 80 20 * 2,8 4202002030021 Bundle 100
32 2,9 4000003202221 4002003202221 Bundle 60 25 * 3,5 4202002530021 Bundle 80
40 3,7 4000004002321 4002004002321 Bundle 40 32 2,9 4202003230121 Bundle 60
50 4,6 4000005002421 4002005002421 Bundle 20 40 3,7 4202004030021 Bundle 40
63 5,8 4000006302521 4002006302521 Bundle 16 50 4,6 4202005030021 Bundle 20
75 6,8 4000007502621 4002007502621 Bundle 12 63 5,8 4202006330121 Bundle 16
90 8,2 4000009002721 4002009002721 Bundle 8 75 6,8 4202007530021 Bundle 12
110 10,0 4000011002821 4002011002821 Bundle 4 90 8,2 4202009030021 Bundle 8
125 11,4 4000012502921 4002012502921 Bundle 4 110 10,0 4202011030021 Bundle 4
160 14,6 4000016000821 4002016000821 Bundle 4 125 11,4 4202012530021 Bundle 4
200 18,2 4000020000121 4002020000121 Bundle 4 *For d20 and d25 diameter products, SDR7.4 (PN20)
Glass Fiber Reinforced Composite Pipes are suggested.
Note: Our climafaser pipes are green.
PP-R Standard Pipe - PN16 (SDR7,4) PP-R Glass Fiber Reinforced Pipe - PN20 (SDR7,4)
Dia. Thic. Code - White Code - Green Packing Dia. Thic. Code - White Code - Green Packing
(mm) (mm) Type Pc (mm) (mm) Type Pc
20 2,8 4000002004021 4000002004021 Bundle 100 20 2,8 4200002000121 4202002000121 Bundle 100
25 3,5 4000002504121 4000002504121 Bundle 80 25 3,5 4200002500221 4202002500221 Bundle 80
32 4,4 4000003204221 4000003204221 Bundle 60 32 4,4 4200003200321 4202003200321 Bundle 60
40 5,5 4000004004321 4000004004321 Bundle 40 40 5,5 4200004000421 4202004000421 Bundle 40
50 6,9 4000005004421 4000005004421 Bundle 20 50 6,9 4200005000521 4202005000521 Bundle 20
63 8,6 4000006304521 4000006304521 Bundle 16 63 8,6 4200006300621 4202006300621 Bundle 16
75 10,3 4000007504621 4000007504621 Bundle 12 75 10,3 4200007500721 4202007500721 Bundle 12
90 12,3 4000009004721 4000009004721 Bundle 8 90 12,3 4200009000821 4202009000821 Bundle 8
110 15,1 4000011004821 4000011004821 Bundle 4 110 15,1 4200011000921 4202011000921 Bundle 4
125 17,1 4000012504821 4000012504821 Bundle 4 125 17,1 4200012500121 4202012500121 Bundle 4
160 21,9 4000016000921 4000016000921 Bundle 4 160 21,7 4200016000121 4202016000121 Bundle 4
200 27,4 4000020001121 4000020001121 Bundle 4
PP-R Standard Pipe - PN20 (SDR6) PP-R Glass Fiber Reinforced Pipe - PN25 (SDR6)
Dia. Thic. Code - White Code - Green Packing
(mm) (mm) Type Pc Dia. Thic. Code - White Code - Green Packing
20 3,4 4000002000121 4002002000121 Bundle 100 (mm) (mm) Type Pc
200 33,2 4000020000221 4002020000221 Bundle 4 160 26,6 4200016000221 4202016000221 Bundle 4
56
PP-R Aquasystem
PP-R Middle Aluminum Foiled Pipe- PN20 (SDR6) PP-R UV Resistant Standard Pipe - PN20 (SDR6)
Dia. Thic. Code - White Code - Green Packing Dia. Thic. Code - White Code - Green Packing
(mm) (mm) Type Pc (mm) (mm) Type Pc
20 3,4 4100002010021 4102002010021 Bundle 100 20 3,4 4000002010021 4002002010021 Bundle 100
25 4,2 4100002510021 4102002510021 Bundle 80 25 4,2 4000002510021 4002002510021 Bundle 80
32 5,4 4100003210021 4102003210021 Bundle 40 32 5,4 4000003210021 4002003210021 Bundle 60
40 6,7 4100004010021 4102004010021 Bundle 40 40 6,7 4000004010021 4002004010021 Bundle 40
50 8,3 4100005010021 4102005010021 Bundle 20 50 8,3 4000005010021 4002005010021 Bundle 20
63 10,5 4100006310021 4102006310021 Bundle 16 63 10,5 4000006310021 4002006310021 Bundle 16
PP-R External Aluminum Foiled Pipe - PN25 (SDR6) PP-R UV Resistant External Aluminum Foiled
Pipe - PN25 (SDR6)
Dia. Thic. Code - White Code - Green Packing
(mm) (mm) Type Pc Dia. Thic. Code - White Code - Green Packing
20 4,5 4100002010021 4102002010021 Bundle 100 (mm) (mm) Type Pc
Dia. Code - White Code - Green Packing Dia. Code - White Code - Green Packing
(mm) Type Pc (mm) Type Pc
20 4300102000721 4302102000721 Cartonbox 400 20 4300502020021 4302502020021 Cartonbox 500
25 4300102500821 4302102500821 Cartonbox 250 25 4300502520121 4302502520121 Cartonbox 350
32 4300103200921 4302103200921 Cartonbox 125 32 4300503220221 4302503220221 Cartonbox 200
40 4300104001021 4302104001021 Cartonbox 75 40 4300504020321 4302504020321 Cartonbox 125
50 4300105001121 4302105001121 Cartonbox 40 50 4300505020421 4302505020421 Cartonbox 30
63 4300106301221 4302106301221 Cartonbox 20 63 4300506320521 4302506320521 Cartonbox 18
75 4300107501321 4302107501321 Cartonbox 16 75 4300507520621 4302507520621 Cartonbox 10
90 4300109001421 4302109001421 Cartonbox 8 90 4300509020721 4302509020721 Cartonbox 8
110 4300111001521 4302111001521 Cartonbox 3 110 4300511020821 4302511020821 Cartonbox 4
125 4300112501622 4302112501622 Cartonbox 2 125 4300512520922 4302512520921 Cartonbox 7
160 4300116001421 4302116001421 Cartonbox 2 160 4300516000121 4302516000121 Cartonbox 4
For butt fusion type, please contact with Product Manager
Dia. Code - White Code - Green Packing 125-75 4300412512022 4302412512022 Cartonbox 5
(mm) Type Pc 125-90 4300412512122 4302412512122 Cartonbox 7
20-25 4300402011021 4302402011021 Cartonbox 100 125-110 4300412512222 4302412512222 Cartonbox 5
25-32 4300402511121 4302402511121 Cartonbox 75 160-110 4300416011921 4302416011921 Cartonbox 1
58
PP-R Aquasystem
4300902506121
25 Cartonbox 300
25 4300902508121 4302902508121 Cartonbox 150
4300903206221
32 Cartonbox 100
32 4300903208221 4302903208221 Cartonbox 100
4300904006321
40 Cartonbox 75
40 4300904008321 4302904008321 Cartonbox 20
4300905006421
50 Cartonbox 40
50 4300905008421 4302905008421 Cartonbox 30
4300906306521
63 Cartonbox 20
63 4300906308521 4302906308521 Cartonbox 8
4300907506621
75 Cartonbox 25
75 4300907508621 4302907508621 Cartonbox 4
4300909006821
90 Cartonbox 18
90 4300909008721 4302909008721 Cartonbox 2
4300911006721
110 Cartonbox 3
110 4300911008821 4302911008821 Cartonbox 3
125 4300912508922 4302912508922 Cartonbox 2
160 4300916009021 4302916009021 Cartonbox 1
For butt fusion type, please contact with Product Manager
Dia. Code - White Code - Green Packing Dia. Code - White Code - Green Packing
(mm) Type Pc (mm) Type Pc
Flange Adapter
Dia. Code - Green Packing
(mm) Type Pc
25 4302902533022 Cartonbox 50
32 4302903233022 Cartonbox 50
PP-R Male Coupler (Round) - (G-Type)
40 4302904033022 Cartonbox 50 Dia. Code - White Code - Green Packing
50 4302905033022 Cartonbox 20 (mm) Type Pc
63 4302906333022 Cartonbox 10 20-1/2" 4300702032021 4302702032021 Cartonbox 250
75 4302907533022 Cartonbox 4 20-3/4" 4300702032121 4302702032121 Cartonbox 50
90 4302909033022 Cartonbox 4 25-1/2" 4300702532221 4302702532221 Cartonbox 200
110 4302911033022 Cartonbox 3 25-3/4" 4300702532321 4302702532321 Cartonbox 200
125 4302912533022 Cartonbox 1 32-3/4" 4300703227321 4302703227321 Cartonbox 100
160 4302916033022 Cartonbox 1 32-1" 4300703232421 4302703232421 Cartonbox 100
60
PP-R Aquasystem
PP-R Male Coupler (Round) - (BSPT-R) PP-R Male Coupler (Hexagonal) - (BSPT-R)
Dia. Code - Green Packing Dia. Code - White Code - Green Packing
(mm) Type Pc (mm) Type Pc
20-1/2" 4302102030221 Cartonbox 200 20-1/2" 4300902010021 4302902010021 Cartonbox 160
20-3/4" 4302102030321 Cartonbox 180 20-3/4" 4300902010121 4302902010121 Cartonbox 80
25-1/2" 4302102530221 Cartonbox 180 25-1/2" 4300902510221 4302902510221 Cartonbox 120
25-3/4" 4302102530321 Cartonbox 100 25-3/4" 4300902510321 4302902510321 Cartonbox 60
32-3/4" 4302103230221 Cartonbox 75 32-3/4" 4300903210421 4302903210421 Cartonbox 30
32-1” 4302103230321 Cartonbox 80 32-1” 4300903210521 4302903210521 Cartonbox 30
62
PP-R Aquasystem
PP-R Union Socket Male (BSPT-R)
PP-R Backplate Elbow Double Female (G-Type)
Dia. Code - Green Packing
(mm) Type Pc Dia. Code - White Code - Green Packing
(mm) Type Pc
20-1/2” 4302702030521 Cartonbox 300
25-1/2” 4300902502121 4302902502121 Cartonbox 40
20-3/4” 4302902030421 Cartonbox 150
25-3/4" 4302702530121 Cartonbox 150
32-1" 4302703230121 Cartonbox 125
40-1.1/4" 4302904030121 Cartonbox 50
50-1.1/2" 4302904030121 Cartonbox 30
63-2” 4302904030121 Cartonbox 20
64
PP-R Aquasystem
PP-R Chromium Valve Short PP-R Pipe Sharpener Plastic
Dia. Code - White Code - Green Packing Dia. Code - White Packing
(mm) Type Pc (mm) Type Pc
20-1/2" 4300802040021 4302802040021 Cartonbox 20 20-25 4300902041022 Cartonbox 70
25-3/4" 4300802540221 4302802540221 Cartonbox 20 32-40 4300903241122 Cartonbox 50
32-1" 4300803240421 4302803240421 Cartonbox 10
Welding Machine
Dia. Code - White Packing
(mm) Type Pc
d20-d125 4301900045082 Metalbox 1
PP-R Chromium Valve Long d20-d100 4301900044382 Cartonbox 1
• Ensures fast and easy installation thanks to its lightweight and • Easy to carry and install due to production in the form of coil.
flexible structure. • Hygienic.
• Resistant to high pressure and temperature. •Thanks to oxygen barrier (EVOH), it ensures full protection
• 100% recyclable environment-friendly against corrosion and oxidation that might occur due to
• High chemical resistance. penetration of oxygen into close-loop system.
• No factors such as corrosion and calcification that reduces
internal diameter.
Fields of Application
- Hot and cold water installations
- Underfloor heating systems
- Drinking water systems
- Heat transfer applications at low/high temperatures
- Transfer of chemicals
- Radiators, air conditioners, coolers
* Approved by KIWA
Technical Properties
Pipe Structure One Layered, Oxygen Barrier, 3 Layered with and without jacket pipe
Diameters [mm] d16-d20
Coil Length [m] 240 m
Maximum Operating Pressure Refer to pressure values that indicated in page 112
Jointing method Mechanical threaded connection
Color Natural
Chemical Resistance Resistant to organic and inorganic chemicals for pH values between 2 and 12
Roughness Ratio 0.007 mm
Maximum Service Temperature 70°C
Maximum Temperature Resistance 95°C
Thermal Conductivity 0.42-0.48 W/m°K
Linear Expansion Coefficient 0.2 mm/m°K
66
PE-XA
Piping Systems
PE-Xa pipes are the three layer pipes with EVOH barrier, specifically produced for heating and cooling
systems. PE-Xa pipes are the most suitable choice to meet project design requirements and ambient
conditions. They are easier to install as compared to other type PE-X pipes.
Infrared lights are used for the purpose of creating peroxide For high performance against temperatures according to TS EN
radicals for the production of PE-Xa pipes. The new and modern 15875 and DIN 16892 standards, pipes must as a minimum have
shortwave infrared technology used to cross link the pipes ensures the following cross linking degrees. PE-X Pipes are divided into 4
higher production speed than conventional methods. The following classes depending upon the cross linking methods:
methods used to cross link polyethylene pipe as PE-X determine PE-XA: Pipes cross linked with peroxide (Minimum 70% cross link)
the type of PE-X pipe. Cross link ratio is over 70%. PE-XB: Pipes cross linked with hydrocyclone (Minimum 65% cross
link)
• Has oxygen barrier characteristics and prevents the penetration PE-XC: Pipes cross linked with radiation (Minimum 60% cross link)
of oxygen in the air through pipe. PE-XD: Pipes cross linked with nitrogen (Minimum 60% cross link)
• High resistance to chemicals.
• Easy to install by using pipe unions without need for heavy Peroxide method is the only process in which cross links are created
equipment. above the melting point (>200°C). As the resulting crystallites are
• Installed in short time without any wastage as they are produced melted during the cross linking, homogenous dispersion of cross
in the form of coils. links in the pipes is achieved.
• No corrosion.
• No reaction with minerals, no diameter reduction.
Technical Properties
Pipe Structure 3 layered
Diameters [mm] d16-d17Coil Length [m] 240 m
Maximum Operating Pressure Refer to pressure values that indicated in page 112
Jointing method Mechanical threaded connection
Color Blue
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Standards EN 15875 , DIN 4726
Cross Linking Ratio >70 % weight
Roughness Ratio 0.007 mm
Maximum Service Temperature 95°C
Maximum Temperature Resistance 110°C
Thermal Conductivity 0.35-0.38 W/m°K
Linear Expansion Coefficient 0.2 mm/m°K
PE-XB
Piping Systems
These are the most preferred pipes systems for heating and cooling pipe systems, made of polyethylene by
cross links and stands out with their flexibility.
• At GF Hakan Plastik, cross linking process for PE-XB pipes is • Oxygen Barrier prevents the penetration and dissolution of
conducted according to the silane method. oxygen in the pipe transmitted and also:
• Complies with EN ISO 15875-2 and DIN 16892 system standards. - Prevents the living and growth of microorganisms; ensures
• Sheathed or unsheathed options are available. confidence in terms of hygiene
• Produced in two different methods for pipes and fittings in the - Prevents the diffusion of oxygen in the pipe and blocks the
diameters of d16, d18, d20, d25 and d32 mm: corrosion of installation components; ensures smooth operation
- Standard Flexa PE-Xb Pipes of radiators and valvaes.
- Oxygen Barrier - Flexa PE-Xb Pipes • Ensures fast and easy installation with O-ring geared connection
mechanism.
Fields of Application
• Hot and cold water distribution systems, drinking water systems • Ice rinks
• Heat transfer applications at low/high temperatures • Transfer of chemicals.
• Floor heating systems. • Radiators, air conditioners, coolers
• Snow melting systems
Technical Properties
Diameter Range [mm] d16 - d32
Maximum Operating Pressure Refer to pressure values that indicated in page 112
Thermal Expansion Coefficient 0,2 mm / m°K
Thermal Conductivity Coefficient 0,41 W/m°K;
Operating Temperature Range -40°C - 95°C
Maximum Temperature Resistance 120°C
68
PE-XA, PE-XB, PE-RT
Oxygen Barrier PE-XB with Red Spiral Cover Oxygen Barrier PE-RT with Spiral Cover
- Hoses packed in the form of coils should be stacked horizontally - Hoses should be used in line with the operating pressures.
and properly to ensure that no deformation occurs. - Hoses should be protected against sharp and perforation
- Storage temperature should be between 10°C and 30°C. impacts.
- As low temperatures cause hoses to get hard and fragile, the - Hoses should not be kept outdoors and under the sunlight.
hoses kept below 10°C should be taken to the normal ambient
temperature (20°C) prior to use.
70
Hose
PVC Transparent Braided Hose - Super Washbasin/ Throat - Washbin Siphon Hose
8 5/16” 2411000813011 Coil 100 12,5 1/2” 2411001200111 Eco Coil 100
10 3/8” 2411001013111 Coil 100 12,5 1/2” 2411001200211 Super Coil 100
16 5/8” 2411005800211 Eco Coil 100
19 3/4” 2411003400411 Super Coil 100
25 1” 2411010000511 Super Coil 50
32 1.1/4” 2411011400611 Super Coil 50
38 1.1/2” 2411011200711 Super Coil 50
72
Hose
Mid Pressure Thermo Water Hose PVC Braided Hose- Garden Phosphorous Green
74
Installation
1 2
3 4
5 6
7 8
Mark the part of the pipe that will be Apply a lubricating liquid
attached to the fitting as much as (silicone etc.) to the socket
the jointing distance. part of the pipe.
9 10
11
76
Installation
1- While fixing the pipe with clamps, pay special attention to not 5- While fitting the fixed clamp, pay attention to keep 10 mm
cause any tension and stress on pipes. distance left on the flat end for expansion.
2- Pipe cannot move after tightening the screws of the fixed 6- Use a fixed clamp after each fitting or fitting group.
clamps. For sliding clamps, pipe will continue to move inside the 7- All clamps to be added to the system apart from the fixed
clamp even after tightening the screws. clamps in the horizontal or vertical line should be sliding clamp
3- For each line longer than 2 m, use 1 fixed clamp immediately that allows for thermal expansion caused by temperature
after the muff part. changes.
4- In vertical lines, always place the fixed clamp on the top point 8- Pipes and fittings should be fixed in short distances so that
of the pipe and below the socket part. they do not slide and release.
Clamp Distance
Nominal External Diameter
DN [mm]
For Horizontal Pipe Directions* Dmax m (max. 15 x da) For Vertical Pipe Directions* Dmax. m
50 0,75 1,50
75 1,10 2,00
90 1,35 2,00
In the vertical lines, one group double and one single clamp should be used on each floor. In the horizontal lines, it is more suitable to use
single clamp.
Clamp Details
The clamp on top, which is one of the double clamps used in the vertical lines, is fully tightened and
grasps the pipe. The lower clamp is tightened up to the plastic wedges on the clamp. It is ensured that
the rubber surfaces of the clamp are not jointed. In this system, the purpose is to absorb the vibration
transmitted from waste water to pipe inside the first clamp and to minimize the vibration on the wall
through the second clamp.
The single clamp in the vertical lines is tightened up to the plastic wedges on the clamp and it is ensured
that the pipe is fixed to the wall. The single clamp in the horizontal lines is tightened up to the plastic
wedges on the clamp and it is ensured that the pipe is fixed to the ceiling or wall.
Although there are different types of silent pipe clamps, they are
available in two kinds as fixed and movable.
78
Installation
The clamp on top, which is one of the double clamps used in the
vertical lines, is fully tightened and grasps the pipe. The lower
clamp is tightened up to the plastic wedges on the clamp. It is
ensured that the rubber surfaces of the clamp are not jointed. In
this system, the purpose is to absorb the vibration transmitted
from waste water to pipe inside the first clamp and to minimize
the vibration on the wall through the second clamp.
80
Installation
Aquasystem PP-R and PP-RCT Piping Systems
Make sure that pipes, fittings and welding machine are clean.
1 2
Before operating the socket fusion machine, make sure that the working area
is safe. To avoid the rotation and movement of parts, welding plates should be
appropriately placed into the welding machine.
3 4
Connect the welding machine to 220 Volts standard socket. Adjust the
temperature as 260°C (500 °F). Push the power button. Heating will take 1 to
3 minutes. When the temperature reaches 260°C (500°F), thermostat light will
switch off automatically.
5 6
7 8 9
PP-RCT Pipes are fully compatible and weldable with our PP-R fittings:
• Same tooling/equipments
• Same welding parameters
• Same assembling instructions
Installation
10 11 12 13
After heating, take out the pipes Push the pipe into the fitting at After jointing it, wait for the cooling After cooling, the connection will be
and fittings from the welding straight angle without rotating it, process by following the cooling ready for use.
mould carefully. and joint it quickly. times indicated.
• After using it, switch off and disconnect the machine. Wait for operation, always beware of the position of the machine. Make
it to cool. Never use water to cool the welder because it will sure that welding plates are tightly fitted and not loose. Always
damage the metal heated. Always keep the welding plates dry. take occupational safety measures.
• Do not perform welding operation in ambient temperatures • Cut the pipes vertically by using the proper cutters. Make sure
below 5°C. As PP-R material is fragile in cold weather that the cutters are sharp.
conditions, treat the pipes with more attention in those • To guarantee a perfect connection, make sure that the
conditions. surfaces of the welding plates are in good quality and the
• While working with the welding machine, wear appropriate surfaces are always clean.
hand and arm protective gloves to avoid the risk of burning.
Wearing protection goggles are also recommended. During the
Test Instructions
82
Installation
The following tables indicate the example expansion calculations with different temperature differences of products with different thermal expansion coefficients.
Thermal Expansion of Glass Fiber Reinforced (Faser) PP-R Pipes [mm] α = 0.035 mm/m°K
Temperature Differences (°C)
Pipe Length (m) 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C
1,0 0,4 0,7 1,1 1,4 1,8 2,1 2,5 2,8
2,0 0,7 1,4 2,1 2,8 3,5 4,2 4,9 5,6
3,0 1,1 2,1 3,2 4,2 5,3 6,3 7,4 8,4
4,0 1,4 2,8 4,2 5,6 7,0 8,4 9,8 11,2
5,0 1,8 3,5 5,3 7,0 8,8 10,5 12,3 14,0
6,0 2,1 4,2 6,3 8,4 10,5 12,6 14,7 16,8
7,0 2,5 4,9 7,4 9,8 12,3 14,7 17,2 19,6
8,0 2,8 5,6 8,4 11,2 14,0 16,8 19,6 22,4
9,0 3,2 6,3 9,5 12,6 15,8 18,9 22,1 25,2
10,0 3,5 7,0 10,5 14,0 17,5 21,0 24,5 28,0
Free Expansion
Amin; Minimum thermal expansion compensation width (mm) SF; Fixed Point
SD; Safety gap (150 mm) SP; Sliding Point
∆L; Total elongation of the system from fixed point (mm) LDN; Length of free bending part (mm)
d; External diameter of pipe (mm)
L; Length of pipe
Thermal expansion direction ∆L; Total thermal expansion (or contraction) (mm)
L; Pipe Length (m)
K; Material constant (K=30)
Free expansion
Temperature
Difference Clamp Distances (cm)
ΔT (°C) d20 d25 d32 d40 d50 d63 d75 d90 d110 d125 d160
Standard PP-R Pipes
0 85 105 125 140 165 190 205 220 250 270 290
20 60 75 90 100 120 140 150 160 180 200 230
30 60 75 90 100 120 140 150 160 180 200 230
40 60 70 80 90 110 130 140 150 170 180 200
50 60 70 80 90 110 130 140 150 170 180 200
60 55 65 75 85 100 115 125 140 160 170 180
70 50 60 75 80 95 105 115 125 140 155 180
84
Installation
Temperature
Difference Clamp Distances (cm)
ΔT (°C) d20 d25 d32 d40 d50 d63 d75 d90 d110 d125 d160
Glass Reinforced PP-R
0 115 130 150 165 185 215 240 260 280 300 320
20 90 100 115 130 145 165 185 200 215 225 250
30 90 100 115 130 145 165 185 200 210 235 255
40 80 90 105 120 135 155 175 190 200 215 230
50 80 90 105 120 135 155 175 190 180 200 210
60 70 80 100 115 130 145 165 180 175 190 200
70 65 75 90 105 120 135 155 175 175 190 200
Temperature
Difference Clamp Distances (cm)
ΔT (°C) d20 d25 d32 d40 d50 d63 d75 d90 d110 d125 d160
Aluminum Foil Pipes
0 120 140 160 180 205 230 245 260 280 300 320
20 90 105 120 135 155 175 185 200 215 225 250
30 90 105 120 135 155 175 185 200 210 235 255
40 85 95 110 125 145 165 175 190 200 215 230
50 85 95 110 125 145 165 175 190 180 200 210
60 80 90 105 120 135 155 165 180 175 190 200
70 70 80 95 110 130 145 165 175 175 190 200
Cut vertically. Enlarge and clean the hole Place the nut and ring.
1 2 3
1 2 3
1. PE-Xb pipes should be supported with 2. Edger legs could be added to each 3. After the tightness test, the system is
90°C edge turner. Edge turner compensates other and could be fixed to the floor. ready for cement finish.
the expansion of pipe and removes internal
stress. This prevents cracks that might result
in water leakage.
Utility Range
86
Corrugated
Piping Systems
GF Hakan Plastik Corrugated piping system is produced in two-layers from high density polyethylene (HDPE)
according to EN 13476-3 standard.
• Product range consists of 100 mm to 1000 mm pipes with or • Can be used in underground drainage systems and areas with
without socket and fittings intense traffic load
• Double layer structure increases the hardness of pipe. With its • Resistant to temperature changes and chemicals and suitable
specially designed frame structure, it is quite resistant to heavy soil for transfers of acidic liquids
and traffic loads • Flexible, suitable for easy use and installation
• Smooth internal surface prevents deposition of solid wastes. •Does not cause leaking and abrasion, demonstrates high
Offers superior hydraulic capacity resistance
Fields of Application
Drainage Systems
- All underground and aboveground discharge systems
- Sewage systems
- Industrial waste water drainage systems
- Domestic waste water drainage systems
- Drainage and ground waters transfer lines
- Non-pressurized water transmission systems
- Discharge systems
- Rainwater discharge systems
88
Technical Properties
Diameters [mm] d100 mm - d1000 mm / Perforated d100 mm, d150 mm, d200
Ring Stiffness SN4 and SN8
Pipe Length [m] 7 m and 6 m
Jointing method Sealed Rubber gasket Push-fit
Color Outer layer: Black / Inner layer: Blue - SN4 Orange stripe, SN8 Blue stripe
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Installation Temperature Minimum: -10°C Maximum: 35°C
Operating Temperature Minimum: -10°C Maximum: 35°C
Standard EN 13476-3
Approvals and Certificates Russia: GOST, Poland: REKOMENDACJA, Ukraine: SEPRO, Turkey: TSE
Corrugated
Corrugated Pipe with Internal Muff
Corrugated Pipe with Muff HDPE - SN4
HDPE - SN4
Dia. Leng. SN Code Dia. Leng. SN Code
[mm] [m] [mm] [m]
800 6 8 5210080000231
Dia. Leng. SN Code
[mm] [m] 1000 6 8 5210090100231
150 6 8 5210015000531
200 6 8 5210020000631
300 6 8 5210030000731
400 6 8 5210040000931 Perforated Corrugated Pipe without
500 6 8 5210050001031 Muff HDPE- SN4
600 6 8 5210060001031 Dia. Leng. SN Code
[mm] [m]
150 7 4 5210015000331
200 7 4 5210020000431
Corrugated Pipe without Muff HDPE - SN4
100 6 8 5210010000231
Dia. SN Code
150 6 8 5210015001931 [mm]
200 6 8 5210020001931
100 8 7410011030031
300 6 8 5210030002031
400 6 8 5210040002231
500 6 8 5210050002131
600 6 8 5210060001931
800 6 8 5210080000331
1000 6 8 5210090100531
90
Corrugated
Socket
Tee Branch with Corrugated Outlet 90°
Dia. Code
Dia. Code [mm]
[mm]
150 5310515000131
150x150 5310215002431 200 5310520000231
200x150 5310220002531 300 5310530000431
200x200 5310220002631 400 5310540000531
300x150 5310230003031 500 5310550000631
300x200 5310230003131 600 5310560000731
400x150 5310240003331 800 5310580000832
400x200 5310240003431 1000 5310590100932
400x400 5310240003631
500x150 5310250003731
500x200 5310250003831
600x150 5310260004131
Telecommunicaion Pipe Socket
Dia. Code
[mm]
Dia. Code
[mm]
150x160 5310215001531
200x160 5310220001631
PP 200x200 5110220001721
300x160 5310230001831
PP 300x200 5110230001921
PP 400x200 5110240002021
PP 500x200 5110250021721
Corrugated Support
Fields of Application
• Removal of harmful waters in agricultural lands • Drainage of emergency lanes
• Foundation drainage of construction site • Railway drainage applications
• Reclamation of muddy and argilliferous lands • Irrigation infrastructure drainage applications
• Reclamation of highway shoulders • All drainage applications in airports, schools, hospitals, hotels,
• Removal of base water in the structures that have base water mass housing projects, golf courts and industrial buildings.
• Drainage of sports areas
Technical Properties
Structure One Layered, perforated and unperforated
Diameters [mm] d100, d125, d160, d200
Pipe Length [m] 50 and 100 meters in the form of coil
Color Yellow
Approvals and Certificates Turkey: TSE
92
PVC-U Drainage
Drainage Socket
Drainage Elbow 45°
Dia. Code Packing
[mm] Type Pc
Dia. Code Packing
[mm] Type Pc 2305511004011 Cartonbox 25
100
2305112500311 Bundle
125 2 2305512504111 Cartonbox 19
125
2305116000511 Bundle
160 2 2305516004211 Cartonbox 8
160
2305120000711 Bundle
200 2 2305520004311 Cartonbox 5
200
They are produced in two types as high and low density for gas and water systems:
• Welding methods such as electrofusion, butt and socket can be jointed quickly and practically.
• Produced in accordance with TS EN 12201-2, TS EN 1555-2 standards.
Technical Properties
Diameter Ranges [mm] d20 - d110 mm for PE 32
d20 - d400 mm for PE 80
d20 - d630 mm for PE 100
d200 - d500 mm for PE 100 RC
Pressure Classes PN6 and PN10 for PE 32 and PE 80
PN4 - PN5 - PN6 - PN8 - PN10 - PN12,5 - PN16 - PN20 - PN25 for PE 100 and PE 100 RC
Operating Temperature Range -40°C - 40°C
Connection Type Electrofusion Welding, Butt Welding, Socket Fusion Welding, Flanged Connection,
Mechanical Connection
Thermal Expansion Coefficient 0,18 mm/m°K
Approvals and Certificates Turkey: TSE, Germany: DVGW, HYGIENE, America: NSF, UK: WRAS, Russia: HYGIENE,
Bulgaria: NJN
Fields of Application
• Pressurized drinking water network
• Waste water discharge and waste water
pumping lines
• Irrigation systems, undersea passage lines and
deep sea discharges
• Underground fire extinguishing systems
(Hydrant lines)
• Cooling water systems
• Telecommunication systems and mining
• Natural Gas Transport, LPG Systems
94
Polyethylene
Dia. PN4 PN5 PN6 PN8 PN10 PN12,5 PN16 PN20 PN25
[mm] SDR41 SDR33 SDR26 SDR21 SDR17 SDR13,6 SDR11 SDR9 SDR7,4
20 - - - - - - 2 2,3 3
25 - - - - - 2 2,3 3 3,5
32 - - - - 2 2,4 3 3,6 4,4
40 - - - 2 2,4 3 3,7 4,5 5,5
50 - - 2 2,4 3 3,7 4,6 5,6 6,9
63 - - 2,5 3 3,8 4,7 5,8 7,1 8,6
75 - - 2,9 3,6 4,5 5,6 6,8 8,4 10,3
90 - - 3,5 4,3 5,4 6,7 8,2 10,1 12,3
110 - - 4,2 5,3 6,6 8,1 10 12,3 15,1
125 - - 4,8 6 7,4 9,2 11,4 14 17,1
140 - - 5,4 6,7 8,3 10,3 12,7 15,7 19,2
160 - - 6,2 7,7 9,5 11,8 14,6 17,9 21,9
180 - - 6,9 8,6 10,7 13,3 16,4 20,1 24,6
200 - - 7,7 9,6 11,9 14,7 18,2 22,4 27,4
225 - - 8,6 10,8 13,4 16,6 20,5 25,2 30,8
250 - - 9,6 11,9 14,8 18,4 22,7 27,9 34,2
280 - - 10,6 13,4 16,6 20,6 25,4 31,3 38,3
315 7,7 9,7 12,1 15 18,7 23,2 28,6 35,2 43,1
355 8,7 10,9 13,6 16,9 21,1 26,1 32,2 39,7 48,5
400 9,8 12,3 15,3 19,1 23,7 29,4 36,3 44,7 54,7
450 11 13,8 17,2 21,5 26,7 33,1 40,9 50,3 61,5
500 12,3 15,3 19,1 23,9 29,7 36,8 45,4 55,8 -
560 13,7 17,2 21,4 26,7 33,2 41,2 50,8 62,5 -
630 15,4 19,3 24,1 30 37,4 46,3 57,2 70,3 -
Fields of Application
• Pressurized water networks, supply of urban drinking water • Industrially-treated liquids and industrial waste discharge
• Pipelines for ventilation systems, swimming pool facilities • Network and cable system installation
• Transfer of acids, alkalis and harmful chemicals • Supply of water in agricultural irrigation and rural areas.
• Pumped waste water networks
Technical Properties
Diameters [mm] d20 - d500 mm
Pressure Classes PN6 - PN8 - PN10 - PN12,5 - PN16 - PN20
Operating Temperature Range 0°C - 60°C
Connection Type Rubber gasket (Push-Fit) socket and solvent cementing
Color Black
Approvals and Certificates Turkey: TSE, Russia: GOST, Ukraine: SEPRO, HYGIENE
96
PVC Pressurized Potable Water Pipes
Not 2 - S20 ve S16 için PN 6 değerleri, tercih edilen sayı olarak 6,3 alınarak hesaplanır
Technical Properties
Diameters [mm] d88 - d330
Pipe Length [mm] 2m-3m-4m
Jointing method Threaded
Color Light Grey
Installation Very easy to install as it is lightweight
Chemical Resistance Resistant to organic and inorganic chemical environments for pH values between 2 and 12
Standard TS 11794
Installation Temperature Minimum: -10oC Maximum: 60oC
Operating Temperature Minimum: -10oC Maximum: 60oC
Approvals and Certificates Russia: GOST, Ukraine: SEPRO - HYGIENE, Turkey: TSE
• This is a type of pipe used for the wells drilled to extract Dia. Code
[mm]
underground waters
88 1900908801211
113 1900911301311
125 1900912501411
140 1900914001511
175 1900917501611
200 1900920001711
225 1900922501811
280 1900928001911
Reduction
Dia. Code
[mm]
88-113 1900408800111
113-125 1900411300211
125-140 1900412500311
140-175 1900414000411
175-200 1900417500511
200-225 1900420000611
225-280 1900422500711
98
Deep Well Pipes
Flat Type Deep Well Pipe / 0-100 m Depth (C3) Filter Type Deep Well Pipe / 0-100 m Depth (C3)
Flat Type Deep Well Pipe / 0-300 m Depth (C2) Filter Type Deep Well Pipe / 0-300 m Depth (C2)
100
Installation
Corrugated
Pipes and Fittings
1. Corrugated Pipes and Fittings are produced as self socketed. 4. The final form of the ring should be in a way that the part looking
2. For easy installation, lubricating liquids (silicone-based liquid) like a dome stays outside.
should be applied on the sealed and socketed parts before jointing 5. Make sure that the pipes are equally aligned prior to installation.
process. Do not use mineral oils and chemicals such as liquid 6. Pipes are jointed in flat angle by pushing with the aid of a
soap etc. that might damage rings. construction equipment, with the small size pipes being placed
3. For sealed jointing, one side of the ring suitable for pipe diameter manually or by a lever and the big size pipes being fitted by placing
is placed into the second groove of the pipe. The other part is fitted a wooden support part to the end of the pipe.
into the slot manually or by using a jimmy.
Soil Surface
Sleeve Layer
Cushion Layer
Natural Layer
In underground applications where trench is drilled, the trench traffic and soil loads on the pipes will be partly transferred to the
should be filled by means of compacting in layers so that no weak filler and the pipes will continue to serve smoothly during their
areas are left around the pipes in order to use corrugated pipes lifetime. If they are not properly compacted, gaps will occur and
and fittings smoothly for long years. It is particularly important to the pipes will fail to transfer the load to the other forces, resulting
fill the base of the pipes with filler. If the filling process is carried in the risk of collapse.
out by compacting them properly according to the specifications,
102
Installation
Polyethylene
Pipes and Fittings
• The installation rules of the PE pipes should be in compliance • If the soil generated during excavation is suitable, there is no need
with ATV-A 127 and EN 805 standards. for bedding and the duct is filled. If the soil is not suitable (stony or
• Pipes should be protected against deformation during the wet), the height of the duct should be increased and bedding should be
application and the pipes damaged during transport - storage carried out on the base by using dry filler.
should never be used. • Bedding thickness should be minimum C1 = 100 mm + 1/10 DN. 95%
• There should be no accumulation of underground water or compacting should be ensured by using a compactor on the bedding
rainwater inside the duct. Otherwise, such water should be material.
discharged by using a pump. • Side fillers of pipes should be poured with C2 = 30 cm thickness
• It is suitable to use incohesive sands, gravels, mixed grained and 95% compacting should be ensured by a compactor. This process
sands and gravels as filler. should be carried out every 30 cm until it covers 30 cm above the pipe.
• Depth of duct may vary depending upon the weather conditions. • After it covers C3=30 cm on the pipe, filling process should be
It should be minimum 70-80 cm. completed by compacting it with the aid of a mid-power compactor.
Pipe Wall Thickness Welding Pressure 0,15 N / [mm]2 Heating Time Heating Iron Pipe Jointing Pressure Cooling
[mm] Wall Height [mm] 0,02 N /mm2 [s] Release time [sn] Operating Time [s] Time [m]
Electrofusion Welding
Polyethylene
Uncontrolled
1. Cutting the Pipes:
Melting
104
Installation
2. Marking the Welding Area 4. Scraping the Pipe Surface
1 1
1 1
2 2
3 3
Installation
6. Placing the Pipe into Sleeve:
1 2
While placing the pipe into the sleeve, ensure that the contact terminals of sleeve stay on
top. Pipes should not be exposed to bending tension and should easily bear their own weight
inside the sleeve. Free ends of pipes could be supported.
Likewise, prepare the other pipe end. Make sure that the pipe and sleeve are at the same
axis. Check the gap between pipe and sleeve along the surrounding of the pipe. If there are
local gaps, disperse the ovality with wooden parts (maximum 3 cm long) and ensure that
the gaps are equal around the entire pipe. Measure the gaps. If gaps are shorter than 2 mm,
proceed with electrofusion welding.
7. Electrofusion Welding:
If you have precisely followed the installation instructions step by scanner or manually. Check the details on the welder screen
step and there are no problems, welding process could be carried and on the barcode. Start the welding process. Upon completion,
out by an universal EF welder. Place the socket ends of the welder always wait as much as cooling period. Do not move the welded
into the contact terminals of the sleeve. Welding details are area during this period of time.
indicated on the barcode label on GF sleeve. Enter the welding
details into the welder automatically with the aid of a barcode
1 2
106
Installation
Flange Adaptor
Stud Bolt + Nut
HDPE Pipe
Jointing with EF
Sleeve
Jointing
with Butt
Welding
PVC-U
Pressurized Potable Water
Piping Systems
Connection of Push-Fit Pipes with Socket:
108
Installation
1 2 3 4
5 6 7 8
9 10 11 12
PVC-U Drainage
Piping Systems
• Pipes should be protected against sunlight during storage as
they do not contain UV additives.
• Pipes taken to the installation site in the form of coils are Soil Trench
spread on the soil area excavated depending upon the condition
of soil and ground. Gravel
110
Packaging
GF Hakan Plastik pipes and fittings are packed as ready for
transport in a customer-friendly way. Packing ensures safety,
efficient storage and easy transport.
Waste water pipes are shipped
on wooden frames or pallets
according to the demands of
customers.
CORRECT
WRONG
Pipes and fittings with socket are placed in a way that they will Short parts with the length of 150, 250 and 500 mm are packed in
not stay on top of each other. carton boxes like connection parts.
Pipes are packed by plastic clamps to hold them together. Stretch All product ranges are identified in the Warehouse Management System
film is applied to protect pipes from pipes dust and stains. (WMS) by barcode label. Barcode system ensures management of
products and prevents complexity and errors during storage and loading.
Storage
112
Transportation
114
Temperature, Pressure and Service Life Tables
116
Chemical Resistance Tables ++ Resistant
+ Limited Resistance
O Contact GF Hakan Plastik
- Not Resistant
PVC-U - PP ++ ++ ++ O
Chemical Resistance
PE -
Aqua regia Fluid Temperatures PP -
20 °C 40 °C 60 °C 80 °C
PVC-U O - Butadiene, gaseous Fluid Temperatures
PE - 20 °C 40 °C 60 °C 80 °C
PP - PVC-U ++ O -
PE O -
Arsenic acid, 80% aqueous solutions Fluid Temperatures PP O -
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ O - Butane, gaseous Fluid Temperatures
PE ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PP ++ ++ ++ ++ PVC-U ++ ++ O -
PE ++ ++ O -
Barium salts, aqueous, saturated PP ++ ++ O -
Fluid Temperatures
solutions
20 °C 40 °C 60 °C 80 °C Butanediol-1,4, Fluid Temperatures
PVC-U ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U O -
PP ++ ++ ++ ++ PE ++ ++ ++ -
PP ++ ++ ++ O
Beer Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Butanediol-1,4, technically pure Fluid Temperatures
PVC-U ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U ++ ++ O
PP ++ ++ ++ ++ PE ++ ++ O
PP ++ ++ O
Benzaldehyde Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Butanol Fluid Temperatures
PVC-U - 20 °C 40 °C 60 °C 80 °C
PE ++ O - PVC-U ++ ++ O -
PP ++ O - PE ++ ++ O -
PP ++ ++ O -
Benzene Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Butyl acetate Fluid Temperatures
PVC-U - 20 °C 40 °C 60 °C 80 °C
PE - PVC-U -
PP - PE + O -
PP O -
Benzene sulfonic acid Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Butyl phenol, p-tertiary Fluid Temperatures
PVC-U ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ O - PVC-U O -
PP ++ ++ O - PE O -
PP O -
Benzoic acid, aqueous solutions Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Cadmium salts, aqueous solutions Fluid Temperatures
PVC-U ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U ++ ++ ++ -
PP ++ ++ ++ ++ PE ++ ++ ++ -
PP ++ ++ ++ O
Benzyl alcohol Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Caesium salts, aqueous solutions Fluid Temperatures
PVC-U O - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ O - PVC-U ++ ++ ++ -
PP ++ ++ O - PE ++ ++ ++ -
PP ++ ++ ++ ++
Beryllium salts, aqueous solutions Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Calcium hydroxide, aqueous solution Fluid Temperatures
PVC-U ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U ++ ++ ++ -
PP ++ ++ ++ ++ PE ++ ++ ++ -
PP ++ ++ ++ ++
Boric acid, aqueous solutions Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Calcium salts, aqueous solutions Fluid Temperatures
PVC-U ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U ++ ++ ++ -
PP ++ ++ ++ ++ PE ++ ++ ++ -
PP ++ ++ ++ ++
Brine Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Carbon dioxide, gaseous, anhydrous Fluid Temperatures
PVC-U ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ - PVC-U ++ ++ ++ -
PP ++ ++ ++ ++ PE ++ ++ ++ -
PP ++ ++ ++ ++
Bromine water, aqueous solution Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Carbon tetrachloride Fluid Temperatures
PVC-U O O - 20 °C 40 °C 60 °C 80 °C
PE - PVC-U -
PP - PE -
PP -
Bromine, pure, liquid or gaseous,
Fluid Temperatures
dry and wet
20 °C 40 °C 60 °C 80 °C
PVC-U -
118
Chemical Resistance
Carbonic acid, CO2 in H2O Fluid Temperatures Chromic Acid, >=10-30 %, aqueous
Fluid Temperatures
20 °C 40 °C 60 °C 80 °C solutions
PE ++ ++ ++ - PVC-U + + -
PP ++ ++ ++ ++ PE -
PP -
PE O - PVC-U ++ ++ ++ -
PP O - PE ++ ++ O -
PP ++ ++ O -
PE O - PVC-U ++ ++ ++ -
PP O - PE ++ ++ ++ -
PP ++ ++ ++ ++
PE - PVC-U -
PP - PE O O O -
PP O O O -
PE - PVC-U ++ ++ ++ -
PP - PE ++ ++ O -
PP ++ ++ ++ O
PE ++ ++ O - PVC-U -
PP ++ ++ ++ O PE ++ O O -
PP ++ O - -
PE - PVC-U ++ O -
PP - PE ++ O -
PP ++ O -
PE ++ ++ O - PVC-U ++ ++ O -
PP ++ ++ O - PE ++ ++ O -
PP ++ ++ O -
PVC-U ++ O -
PE O - Dioxane Fluid Temperatures
PP O - 20 °C 40 °C 60 °C 80 °C
PVC-U -
Dichloroacetic acid, <= 50 % aqueous PE ++ O -
Fluid Temperatures
solution PP O -
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ O - Ethanol, <= 50% aqueous solution Fluid Temperatures
PE ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PP ++ ++ O - PVC-U ++ ++ O -
PE ++ ++ ++ -
Dichloroacetic acid methyl ester Fluid Temperatures PP ++ ++ ++ ++
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethyl alcohol, 96% Fluid Temperatures
PE ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PP ++ ++ ++ O PVC-U ++ ++ O -
PE ++ ++ ++ -
Dichlorobenzene Fluid Temperatures PP ++ ++ ++ ++
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethanolamine Fluid Temperatures
PE O - 20 °C 40 °C 60 °C 80 °C
PP O - PVC-U -
PE ++ O -
Dichlorodifluoromethane, gaseous Fluid Temperatures PP ++ O -
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethyl benzene Fluid Temperatures
PE O - 20 °C 40 °C 60 °C 80 °C
PP O - PVC-U -
PE O -
Dichloroethylene Fluid Temperatures PP O -
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethylacetate Fluid Temperatures
PE - 20 °C 40 °C 60 °C 80 °C
PP - PVC-U -
PE ++ O
Diesel oil Fluid Temperatures PP ++ O
20 °C 40 °C 60 °C 80 °C
PVC-U O O - Ethylchloride, gaseous Fluid Temperatures
PE O O - 20 °C 40 °C 60 °C 80 °C
PP O - PVC-U -
PE O -
Diethanolamine, aqueous solution Fluid Temperatures PP O -
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethylene diamine Fluid Temperatures
PE ++ O - 20 °C 40 °C 60 °C 80 °C
PP ++ O - PVC-U -
PE ++ ++ ++ -
Diethyl ether Fluid Temperatures PP ++ ++ ++ O
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethylene glycol Fluid Temperatures
PE O - 20 °C 40 °C 60 °C 80 °C
PP O - PVC-U -
PE + + O -
Diethylamine Fluid Temperatures PP + + O -
20 °C 40 °C 60 °C 80 °C
PVC-U - Ethylene glycol, <= 50% aqueous
Fluid Temperatures
PE ++ O - solution
PP ++ O - 20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ O -
Diisobutyl ketone Fluid Temperatures PE + + O -
20 °C 40 °C 60 °C 80 °C PP + + + O
PVC-U -
PE ++ O - Ethylenediamine tetraacetic acid,
Fluid Temperatures
PP ++ O - aqueous solution
20 °C 40 °C 60 °C 80 °C
PVC-U - PP + + O -
PE O -
PP O - Ferric chloride Fluid Temperatures
20 °C 40 °C 60 °C 80 °C
PVC-U - PP ++ ++ ++ ++
PE ++ ++ O -
PP ++ ++ ++ O Fluorosilicic acid, < = 32 % aqueous
Fluid Temperatures
solutions
20 °C 40 °C 60 °C 80 °C
Dimethylamine Fluid Temperatures
PVC-U ++ ++ ++ -
20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ -
PVC-U -
PP ++ ++ ++ O
PE ++ O -
PP ++ O -
120
Chemical Resistance
PE O - PVC-U O -
PP O - PE O -
PP O -
PE ++ ++ ++ - PVC-U ++ ++ O -
PP ++ ++ ++ O PE ++ ++ ++ -
PP ++ ++ ++ O
PVC-U ++ O -
Hydrofluoric acid, > 40% - 75% PE ++ O -
Fluid Temperatures
aqueous solution PP ++ O -
20 °C 40 °C 60 °C 80 °C
PVC-U - Isopropyl alcohol Fluid Temperatures
PE + + O - 20 °C 40 °C 60 °C 80 °C
PP O O PVC-U ++ O -
PE ++ ++ O -
Hydrofluoric acid, > 75 % aqueous PP ++ ++ O -
Fluid Temperatures
solution
20 °C 40 °C 60 °C 80 °C
Lactic acid, aqueous solution Fluid Temperatures
PVC-U -
20 °C 40 °C 60 °C 80 °C
PE -
PVC-U ++ O O -
PP -
PE + + + -
PP + + + O
Hydrofluoric acid, 10% - 40 %
Fluid Temperatures
aqueous solution
20 °C 40 °C 60 °C 80 °C Lead Acetate Fluid Temperatures
PVC-U O O - 20 °C 40 °C 60 °C 80 °C
PE + + O - PVC-U ++ ++ ++ -
PP + + O O PE ++ ++ ++ -
PP ++ ++ ++ O
Hydrogen chloride, gaseous Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Linseed oil Fluid Temperatures
PVC-U ++ ++ O - 20 °C 40 °C 60 °C 80 °C
PE ++ ++ O - PVC-U ++ ++ O -
PP ++ ++ O - PE ++ ++ O -
PP ++ ++ ++ O
Hydrogen peroxide, < 5 % aqueous
Fluid Temperatures
solution Lithium salts, aqueous saturated
Fluid Temperatures
20 °C 40 °C 60 °C 80 °C solutions
PVC-U ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE + O - PVC-U ++ ++ ++ -
PP O - PE ++ ++ ++ -
PP ++ ++ ++ ++
Hydrogen peroxide, >= 5 % aqueous
Fluid Temperatures
solution Magnesium salts, aqueous, saturated
Fluid Temperatures
20 °C 40 °C 60 °C 80 °C solutions
PVC-U ++ ++ - 20 °C 40 °C 60 °C 80 °C
PE O - PVC-U ++ ++ ++ -
PP - PE ++ ++ ++ -
PP ++ ++ ++ ++
Hydrogen Sulfide gaseous Fluid Temperatures
20 °C 40 °C 60 °C 80 °C Maleic acid, cold saturated, aqueous
Fluid Temperatures
solution
PVC-U ++ ++ O -
20 °C 40 °C 60 °C 80 °C
PE ++ ++ O -
PVC-U ++ O
PP ++ ++ ++ O
PE ++ ++ O
PP ++ ++ O
Hydrogen sulfide, aqueous saturated
Fluid Temperatures
solution
20 °C 40 °C 60 °C 80 °C Mercury salts, aqueous, saturated
Fluid Temperatures
solutions
PVC-U ++ ++ O -
20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ -
PVC-U ++ ++ O -
PP ++ ++ ++ O
PE ++ ++ ++ -
PP ++ ++ ++ ++
Hydrogen, gas Fluid Temperatures
20 °C 40 °C 60 °C 80 °C
Methane, gaseous Fluid Temperatures
PVC-U ++ ++ ++ -
20 °C 40 °C 60 °C 80 °C
PE ++ ++ ++ -
PVC-U ++ O
PP ++ ++ ++ O
PE ++ O
PP ++ O
Hydroquinone, cold saturated
Fluid Temperatures
aqueous solution
20 °C 40 °C 60 °C 80 °C Methanol Fluid Temperatures
PVC-U ++ O - 20 °C 40 °C 60 °C 80 °C
PE ++ O - PVC-U ++ ++ O -
PP ++ O - PE ++ ++ ++ -
PP ++ ++ ++ O
Iron salts, aqueous, saturated
Fluid Temperatures
solutions Methyl acetate Fluid Temperatures
20 °C 40 °C 60 °C 80 °C 20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ - PVC-U -
PE ++ ++ ++ - PE ++ ++ O
PP ++ ++ ++ ++ PP ++ ++ O
122
Chemical Resistance
PVC-U - PVC-U ++ ++ O -
PE - PE ++ ++ O -
PP - PP ++ ++ ++ O
Methyl ethyl ketone Fluid Temperatures Mixed acids: sulfuric / nitric / water,
Fluid Temperatures
20 °C 40 °C 60 °C 80 °C various concentrations
PE ++ O PVC-U O
PP ++ O PE O
PP O
PE ++ O PVC-U -
PP ++ O PE ++ O
PP ++ O
PE ++ ++ O PVC-U -
PP ++ ++ O PE ++ O
PP O
Nitrotoluene (o-, m-, p-) Fluid Temperatures 20 °C 40 °C 60 °C 80 °C
20 °C 40 °C 60 °C 80 °C PVC-U ++ ++ ++ -
PVC-U - PE + + O
PE ++ O PP + + + O
PP O
Phosphoric acid, >60-85 % aqueous
Fluid Temperatures
Nitrous acid Fluid Temperatures solution
PVC-U ++ ++ O - PVC-U + + O -
PE ++ O PE + + O
PP ++ O PP + + O
Nitrous gases (Nitric oxide), Fluid Temperatures Phosphoric acid, >85-95 % aqueous
Fluid Temperatures
solution
20 °C 40 °C 60 °C 80 °C
20 °C 40 °C 60 °C 80 °C
PVC-U ++ O
PVC-U + + O -
PE O
PE + + O
PP O
PP + + O
124
Chemical Resistance
PVC-U ++ ++ O - PE ++ ++ ++ -
PE ++ ++ ++ - PP ++ ++ ++ ++
PP ++ ++ ++ O
Sodium chlorite, aqueous solution Fluid Temperatures
Propane, gaseous Fluid Temperatures 20 °C 40 °C 60 °C 80 °C
20 °C 40 °C 60 °C 80 °C PVC-U ++ ++ ++ -
PVC-U ++ O PE + + O
PE ++ ++ O PP + + O
PP ++ O
Sodium Chromate, diluted aqueous
Fluid Temperatures
Propionic acid Fluid Temperatures solution
PVC-U ++ O PVC-U ++ ++ O
PE ++ O PE O
PP ++ O PP O
Propionic acid, 50% aqueous solution Fluid Temperatures Sodium hydrogen sulfite, Fluid Temperatures
PVC-U ++ ++ O - PVC-U ++ ++ ++ -
PE ++ ++ ++ - PE ++ ++ ++ -
PP ++ ++ ++ O PP ++ ++ ++ ++
PVC-U ++ ++ O - PVC-U O O -
PE + + O - PE O O O -
PP + + + O PP O O O O
PVC-U O
Sodium salts, aqueous, saturated PE O
Fluid Temperatures
solutions PP O
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ - Tannic acid, aqueous solution Fluid Temperatures
PE ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PP ++ ++ ++ ++ PVC-U ++ O
PE ++ O
Starch solution, aqueous solutions Fluid Temperatures PP ++ O
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ - Tartaric acid, <=10% aqueous
Fluid Temperatures
PE ++ ++ ++ - solution
PP ++ ++ ++ ++ 20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ -
Styrene Fluid Temperatures PE ++ ++ ++ -
20 °C 40 °C 60 °C 80 °C PP ++ ++ ++ O
PVC-U -
PE O Tetrachloroethane Fluid Temperatures
PP O 20 °C 40 °C 60 °C 80 °C
PVC-U -
Succinic acid, aquesous solutions Fluid Temperatures PE -
20 °C 40 °C 60 °C 80 °C PP -
PVC-U ++ ++ ++ -
PE ++ ++ ++ - Tetrachloroethylene Fluid Temperatures
PP ++ ++ ++ O 20 °C 40 °C 60 °C 80 °C
PVC-U -
Sulfuric acid, <= 25% aqueous PE O
Fluid Temperatures
solution PP O
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ - Tetrachloromethane Fluid Temperatures
PE ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PP + + + O PVC-U -
PE -
Sulfuric acid, > 25-50% solution Fluid Temperatures PP -
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ - Tetrahydrofurane Fluid Temperatures
PE ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PP + + + + PVC-U -
PE O
Sulfuric acid, > 50 - 70% solution Fluid Temperatures PP O
20 °C 40 °C 60 °C 80 °C
PVC-U + + + - Tetramethyl ammoniumhydroxide Fluid Temperatures
PE ++ ++ ++ - 20 °C 40 °C 60 °C 80 °C
PP + + + O PVC-U ++ O O -
PE ++ O O -
Sulfuric acid, > 70 - 78% solution Fluid Temperatures PP ++ O O
20 °C 40 °C 60 °C 80 °C
PVC-U + + - Tin (II) Chloride, aqueous saturated
Fluid Temperatures
PE ++ ++ ++ - solution
PP + + O O 20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ ++ -
Sulfuric Acid, > 78 - 93% solution Fluid Temperatures PE ++ ++ ++ -
20 °C 40 °C 60 °C 80 °C PP ++ ++ ++ O
PVC-U + + -
PE - Toluene Fluid Temperatures
PP - 20 °C 40 °C 60 °C 80 °C
PVC-U -
Sulfuric acid, > 93 - 96% solution Fluid Temperatures PE O
20 °C 40 °C 60 °C 80 °C PP O
PVC-U + + -
PE - Trichloroacetic acid, aqueous
Fluid Temperatures
PP - solutions
20 °C 40 °C 60 °C 80 °C
PVC-U + O - PP ++ ++ O
PE -
PP - Trichloroethane Fluid Temperatures
20 °C 40 °C 60 °C 80 °C
PVC-U ++ ++ O - PP O
PE ++ ++ O -
PP ++ ++ O - Trichloroethylene Fluid Temperatures
20 °C 40 °C 60 °C 80 °C
PVC-U - PP -
PE -
PP - Trichloromethane Fluid Temperatures
20 °C 40 °C 60 °C 80 °C
126
Chemical Resistance
PVC-U ++ ++ O - PVC-U ++ ++ ++ -
PE ++ ++ ++ - PE ++ ++ ++ -
PP ++ ++ ++ O PP ++ ++ ++ ++
PVC-U - PVC-U -
PE ++ ++ O PE -
PP ++ O PP -
++ Resistant
+ Limited Resistance
O Contact GF Hakan Plastik
- Not Resistant
128
Notes
Notes
130
GF Piping Systems
Worldwide at home
Our sales companies and representatives ensure
local customer support in more than 100 countries.
www.gfps.com
Argentina / Southern South America France Mexico / Northern Latin America Singapore
Georg Fischer Central Plastics Sudamérica S.R.L. Georg Fischer SAS Georg Fischer S.A. de C.V. George Fischer Pte Ltd
Buenos Aires / Argentina 95932 Roissy Charles de Gaulle Cedex CP 66603 Apodaca, Nuevo León / Mexico 528 872 Singapore
Phone +54 11 4512 02 90 Phone +33 (0) 1 41 84 68 84 Phone +52 (81) 1340 8586 Phone +65 6747 0611
[email protected] [email protected] Fax +52 (81) 1522 8906 Fax +65 6747 0577
www.gfps.com/ar www.gfps.com/fr [email protected] [email protected]
www.gfps.com/mx www.gfps.com/sg
Australia Germany
George Fischer Pty Ltd Georg Fischer GmbH Middle East Spain / Portugal
Riverwood NSW 2210 73095 Albershausen Georg Fischer Piping Systems (Switzerland) Ltd Georg Fischer S.A.
Phone +61 (0) 2 9502 8000 Phone +49 (0) 7161 302 0 Dubai / United Arab Emirates 28046 Madrid / Spain
[email protected] [email protected] Phone +971 4 289 49 60 Phone +34 (0) 91 781 98 90
www.gfps.com/au www.gfps.com/de [email protected] [email protected]
www.gfps.com/int www.gfps.com/es
Austria India
Georg Fischer Rohrleitungssysteme GmbH Georg Fischer Piping Systems Pvt. Ltd Netherlands Sweden
3130 Herzogenburg 400 083 Mumbai Georg Fischer N.V. Georg Fischer AB
Phone +43 (0) 2782 856 43-0 Phone +91 22 4007 2000 8161 PA Epe 117 43 Stockholm
[email protected] Fax +91 22 4007 2020 Phone +31 (0) 578 678 222 Phone +46 (0) 8 506 775 00
www.gfps.com/at [email protected] [email protected]
www.gfps.com/in www.gfps.com/nl www.gfps.com/se
Belgium / Luxembourg
Georg Fischer NV/SA Indonesia New Zealand Switzerland
1600 Sint-Pieters-Leeuw / Belgium PT Georg Fischer Indonesia Georg Fischer Ltd Georg Fischer Rohrleitungssysteme (Schweiz) AG
Phone +32 (0) 2 556 40 20 Karawang 41371, Jawa Barat 5018 Upper Hutt
Fax +32 (0) 2 524 34 26 Phone +62 267 432 044 Phone +04 527 9813 Phone +41 (0) 52 631 3026
[email protected] Fax +62 267 431 857 Fax +04 527 9834 [email protected]
www.gfps.com/be [email protected] [email protected] www.gfps.com/ch
www.gfps.com/id www.gfps.com/nz
Brazil Taiwan
Georg Fischer Sist. de Tub. Ltda. Italy Norway Georg Fischer Co. Ltd
04571-020 São Paulo/SP Georg Fischer S.p.A. Georg Fischer AS San Chung Dist., New Taipei City
Phone +55 (0) 11 5525 1311 20864 Agrate Brianza (MB) 1351 Rud Phone +886 2 8512 2822
[email protected] Phone +39 02 921 86 1 Phone +47 67 18 29 00 Fax +886 2 8512 2823
www.gfps.com/br Fax +39 02 921 86 24 7 [email protected] www.gfps.com/tw
[email protected] www.gfps.com/no
Canada www.gfps.com/it United Kingdom / Ireland
Georg Fischer Piping Systems Ltd Philippines George Fischer Sales Limited
Mississauga, ON L5T 2B2 Japan George Fischer Pte. Ltd. Coventry, CV2 2ST / United Kingdom
Phone +1 (905) 670 8005 Georg Fischer Ltd Phone +44 (0) 2476 535 535
Fax +1 (905) 670 8513 530-0003 Osaka 1500 San Juan City [email protected]
[email protected] Phone +81 (0) 6 6341 2451 Phone +632 571 2365 www.gfps.com/uk
www.gfps.com/ca [email protected] Fax +632 571 2368
www.gfps.com/jp [email protected] USA / Caribbean
China www.gfps.com/sg Georg Fischer LLC
Georg Fischer Piping Systems Ltd Korea 92618 Irvine, CA / USA
Shanghai 201319 Georg Fischer Korea Co. Ltd Poland Phone +1 714 731 8800
Phone +86 21 3899 3899 Unit 2501, U-Tower Georg Fischer Sp. z o.o. Fax +1 714 731 6201
[email protected] 120 Heungdeok Jungang-ro 05-090 Sekocin Nowy [email protected]
www.gfps.com/cn (Yeongdeok-dong) Phone +48 (0) 22 31 31 0 50 www.gfps.com/us
Giheung-gu, Yongin-si, Gyeonggi-do [email protected]
Denmark / Iceland Phone +82 31 8017 1450 www.gfps.com/pl Vietnam
Georg Fischer A/S Fax +82 31 217 1454 George Fischer Pte Ltd
2630 Taastrup / Denmark [email protected] Romania
Phone +45 (0) 70 22 19 75 www.gfps.com/kr Georg Fischer Piping Systems (Switzerland) Ltd Ho Chi Minh City
[email protected] 020257 Bucharest - Sector 2 Phone + 84 28 3948 4000
www.gfps.com/dk Malaysia Phone +40 (0) 21 230 53 80 Fax + 84 28 3948 4010
George Fischer (M) Sdn. Bhd. [email protected] [email protected]
Finland 41200 Klang, Selangor Darul Ehsan www.gfps.com/int www.gfps.com/vn
Georg Fischer AB Phone +60 (0) 3 3122 5585
01510 Vantaa Fax +60 (0) 3 3122 5575 Russia International
Phone +358 (0) 9 586 58 25 [email protected] Georg Fischer Piping Systems (Switzerland) Ltd Georg Fischer Piping Systems (Switzerland) Ltd
Fax +358 (0) 9 586 58 29 www.gfps.com/my Moscow 125040
[email protected] Phone +7 495 748 11 44 Phone +41 (0) 52 631 3003
www.gfps.com/fi [email protected] Fax +41 (0) 52 631 2893
www.gfps.com/ru [email protected]
www.gfps.com/int
The information and technical data (altogether “Data”) herein are not binding, unless explicitly confirmed in writing.
The Data neither constitutes any expressed, implied or warranted characteristics, nor guaranteed properties or a guaranteed
durability. All Data is subject to modification. The General Terms and Conditions of Sale of Georg Fischer Piping Systems apply.
GF Piping Systems
Diyarbakır
Şanlıurfa Bulvarı Fırat Mh.
Ahmede Hani Cd. No:4
Yektower İş Merkezi No:13/39
Kayapınar / DİYARBAKIR
Tel: +90 412 251 18 20
Fax: +90 412 251 18 25
Samsun
Kuzey Yıldızı Mah. 100.Yıl Bulv.
No:38 Kat:4 Daire:23 Baran Plaza
Canik / SAMSUN
Tel: +90 362 256 02 33 - 03 33
Ankara
Mustafa Kemal Mahallesi
2131. Cadde Akay İş Merkezi 30-9
Çankaya / ANKARA