Modbus TCP/IP: HMI Setting

This document provides information about connecting an MT8000 HMI to a Modbus TCP/IP device via Ethernet. It lists the recommended HMI and PLC settings, such as using Modbus TCP/IP as the PLC type and Ethernet as the com port in the HMI settings. It also specifies the Ethernet wiring diagrams whether connecting via an Ethernet hub/switch or directly with a crossover cable. The device address ranges and formats are listed for different data types including bits, input/output registers, and double/single words.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views

Modbus TCP/IP: HMI Setting

This document provides information about connecting an MT8000 HMI to a Modbus TCP/IP device via Ethernet. It lists the recommended HMI and PLC settings, such as using Modbus TCP/IP as the PLC type and Ethernet as the com port in the HMI settings. It also specifies the Ethernet wiring diagrams whether connecting via an Ethernet hub/switch or directly with a crossover cable. The device address ranges and formats are listed for different data types including bits, input/output registers, and double/single words.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Modbus TCP/IP

Modbus RTU TCP/IP device.


http://www.modbus.org

HMI Setting:
Parameters Recommend Option Notes
PLC type MODBUS TCP/IP
Com port Ethernet
HMI Station No. 0 Does not apply
PLC Station No. 0 0~255
TCP/IP port 502

PLC Setting:
Communication mode

Device address:
Bit/Word Device Type Format Range Memo
B 1x ddddd 1-65535 Output bit
B 0x ddddd dd 1-65535 Input bit
B 3x_bit ddddd dd 100-6553515 Input Register bit (read only)
B 4x_bit ddddd dd 100-6553515 Output Register bit
B 6x_bit Ddddd dd 100-6553515 Output Register bit
W 3x ddddd 1-65535 Input Register
W 4x ddddd 1-65535 Output Register
DW 5x ddddd 1-65535 4x double word swap
W 6x ddddd 1-65535 4x single word write
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color Ethernet Hub or Switch
RJ45 RJ45
1 TX+ White/Orange 1 RX+
1 8
2 TX- Orange 2 RX-
RJ45 connector
3 RX+ White/Green 3 TX+
4 BD4+ Blue 4 BD4+
5 BD4- White/Blue 5 BD4-
6 RX- Green 6 TX-
7 BD3+ White/Brown 7 BD3+
8 BD3- Brown 8 BD3-

Ethernet: Direct connect (crossover cable)


MT8000 Ethernet Wire color Modbus TCP Device
RJ45 RJ45
1 TX+ White/Orange 3 RX+
2 TX- Orange 6 RX-
3 RX+ White/Green 1 TX+
4 BD4+ Blue 4 BD4+
5 BD4- White/Blue 5 BD4-
6 RX- Green 2 TX-
7 BD3+ White/Brown 7 BD3+
8 BD3- Brown 8 BD3-