Additive Injection System: Equalis AIM
Additive Injection System: Equalis AIM
Additive Injection System: Equalis AIM
Co u n tum Group
Metering Solutions
Metering Solutions
M
Equalis AIM
Oval gear meter The second key element of the AIM is the solenoid valve to
control the additive injection volume. A fast direct acting valve
Solenoid valve
Check valve with a ruby seat allows for high velocity flows through a small
3mm orifice providing minute proportion control even at high
injection pressures and liquid changing temperatures.
Outlet
AIM is controlled by Equalis S. It accurately injects small
amounts of additives to a base product.
Inlet
Measured additives can be lead replacements, dyes and markers,
Pulses Binary denaturants, detergents, odorizing, antifreeze, anti-corrosion,
Isolating - regulating valves output input anti-detonating, anti-static, anti-icing, anti-foaming, emulsifiers
and performance enhancing agents.
Technical data - Additive Injection System
Model Equalis AIM
Application In-line injection of additives in petroleum products
Functions Metering of additives quantities
Control of additives injection proportionally to additives concentration setpoints
Control of additives pumps via Modbus tables
Calculation of average additives concentrations (ppm) per batch
“Clean arm” function to provide a product without additive in the loading arm at the end of the batch
Secured back-up of the batch data (products and additives quantities, concentrations , time and date…)
Additive injection modules AIM004 AIM006 AIM008
Max. flowrate (L/h – L/min) 60 - 1.0 100 - 1.66 600 – 10
Min. flowrate (L/h – L/min) 0.6 – 0.01 1.8 – 0.03 15 – 0.25
Matérials Back plate 304 stainless steel
Manifold 303 stain less steel
Enclosure UV-resistant impact modified polycarbonate
Meter, valves and strainer 316 stainless steel
Solenoid valve Ruby seat to cover all applications
Isolating, flow regulating and check valves, strainer,
Internal construction Manifold
Solenoid valve, precision oval gear flow meter, Inlet and outlet elbows, inlet and outlet port
Manifold connections 3/8” NPT
Strainer Min 75 μm (200 mesh)
Operating conditions Pressure 10 bar max with 6 - 24VDC solenoid - 20 bar max with 108 - 220VAC solenoid
Ambient temperature -25°C to + 60°C
Humidity 5 to 95% without condensation
Protection class IP66
Performances Meter accuracy +/-0.5% @ 3 mm²/s (cSt)
Meter repeatability +/-0.25%
Additive injection controller Equalis S
Equipment User Interface Display : Graphic screen, 240 x 128 pixels, backlight - Volume resolution : 999999 points
Numeric keyboard, pre-programmed pushbuttons, cycle start/stop pushbutton
Enclosure Aluminum base with epoxy coating
Inputs/Outputs Main meter inputs 1 or 2 inputs dual-pulse with flow direction - Intrinsic safety or NAMUR*
Temperature inputs 1 or 2* inputs (4-wire Pt100)
Digital inputs 15 inputs (intrinsic safety) and 2* input (NAMUR) - Up to 12 inputs dedicated to AIM additives metering
for additive volumes, grounding system, arm position, overfilling system, vapour recovery, emergency stop
Digital outputs 10 (+10*) relays (250V, 10A) - Up to 12 outputs dedicated to additives injection control
for additives injection, valves control, alarm
Databus 1 port RS485 or Ethernet TCP/IP : communication with supervisory system
1 port RS485 or RS232 : printer
Communication protocole : Modbus RTU
1 port USB : Data extraction
Operating conditions
Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C
Certification for potentially explosive ATEX and IEC Ex
atmospheres Zone 1 – II 2 (1) 1 G Ex d [ia Ga] ia IIB T4 Gb Ga
Protection class IP66
Power supply 100 to 240 VAC 50 à 60 Hz-
Dimensions Height x width x depth (mm) : 278 x 350 x 192 (without cable glands) - Weight : 16 kg
* : optional