Engineering Data: Air Conditioners
Engineering Data: Air Conditioners
Engineering Data: Air Conditioners
TS
T−CLASSE SPLIT SYSTEM UNITS
R−410A − 60 HZ
ENGINEERING DATA Bulletin No. 210524
February 2009
Supersedes January 2009
072−090 Models
180−240 Models
EER up to 11.4
120−150 Models 6 to 20 Tons
Cooling Capacity − 66,000 to 236,000 Btuh
I
F
G 180−240 Models
C
K
H
E
D
120−150 Models
J
072−090 Models
Intuitive Touchscreen Interface − Two Stage Heating / Two Stage Cooling Con- C0STAT02AE1L
ventional or Heat Pump − Seven Day Programmable − Four Time Periods/Day −
Economizer Output − Title 24 Compliant − ENERGY STAR® Qualified − Backlit Display −
Automatic Changeover
Condenser Net face area − sq. ft. Outer coil 29.3 29.3
Coil
Inner coil −−− 28.4
Condenser Net face area − sq. ft. Outer coil 29.3 29.3
Coil
Inner coil 28.4 28.4
Rated load amps (total) 30.1 16.7 12.2 18 (32) 7.8 (15.6) 5.7 (11.4)
Locked rotor amps (total) 225 114 80 110 (220) 52 (104) 38.9 (77.8)
Locked rotor amps (total) 4.7 (9.4) 2.4 (4.8) 1.9 (3.8) 4.7 (9.4) 2.4 (4.8) 1.9 (3.8)
NOTE − Extremes of operating range are plus and minus 10% of line voltage.
1 Refer to the Lennox Refrigerant Piping Manual to determine refrigerant charge required with longer length refrigerant lines.
2 HACR type circuit breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
Connections Liquid line − in. (o.d) (2) 5/8 (2) 5/8 (2) 5/8
(sweat)
Suction line − in. (o.d) (2) 1−1/8 (2) 1−1/8 (2) 1−3/8
Condenser Net face area − sq. ft. Outer coil 34.2 58.7 58.7
Coil
Inner coil 33.3 57.7 57.7
Locked rotor amps 6 3 2.9 4.7 2.4 1.9 4.7 2.4 1.9
(total) (12) (6) (5.8) (18.8) (9.6) (7.6) (18.8) (9.6) (7.6)
NOTE − Extremes of operating range are plus and minus 10% of line voltage.
1 Refer to the Lennox Refrigerant Piping Manual to determine refrigerant charge required with longer length refrigerant lines.
2 HACR type circuit breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
WEIGHT DATA
Net Shipping
Model No.
lbs. kg lbs. kg
072 305 138 325 147
090 355 161 375 170
120S 465 211 490 222
120D 480 218 505 229
150 535 243 560 254
180 775 352 800 363
240 865 392 890 404
OPTIONs / ACCESSORIES
Net Shipping
lbs. kg lbs. kg
COIL GUARDS
T2GARD20L−1 40 18 45 20
T2GARD20M−1 45 20 50 23
T2GARD21M−1 45 20 50 23
T2GARD20N−1− 90 41 100 45
HAIL GUARDS
T2GARD10L−1 70 32 75 34
T2GARD10M−1 75 34 80 36
T2GARD11M−1 75 34 80 36
T2GARD10N−1 120 54 130 59
See CONTROL
NOTES BOX ACCESS
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in.
See See (914 mm).
NOTES NOTES Clearance to one of the remaining two sides may be 12 in.
(305 mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. (610 mm) must be maintained between
two units.
48 in. (1219 mm) clearance required on top of unit.
See
NOTES
See
NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be main-
tained on one of the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. See See
(914 mm). NOTES NOTES
Clearance to one of the remaining two sides may be 12
in. (305 mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. (610 mm) must be maintained be-
tween two units.
48 in. (1219 mm) clearance required on top of unit.
See CONTROL
NOTES BOX ACCESS
See
NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be
maintained on one of the sides adjacent to the
control box.
Clearance to one of the other three sides must be
See See 36 in. (914 mm).
NOTES NOTES Clearance to one of the remaining two sides may
be 12 in. (305 mm) and the final side may be 6 in.
(152 mm).
A clearance of 24 in. (610 mm) must be main-
tained between two units.
48 in. (1219 mm) clearance required on top of unit.
See CONTROL
NOTES BOX ACCESS
OPTIONAL
HAIL GUARD
(Field Installed
All Coil Sides)
(Not used with
9-1/8 Coil Guard)
(232) AA INLET AIR BB
LIQUID
1−1/8 LINE CENTER OF
(29) GRAVITY
INLET AIR
5
(127) 1−1/8 SUCTION EE
(29) LINE FF
3−5/8
(92)
DD INLET AIR CC
REFRIGERANT LINE
ELECTRICAL OUTDOOR
CONNECTIONS DETAIL INLETS (Above FAN GUARD
Refrigerant Lines)
TOP VIEW
CONTROL
BOX ACCESS
45-1/4
COMPRESSOR COMPRESSOR (1149)
REFRIGERANT 48-3/4
LINE CONNECTIONS (1238)
SEE DETAIL
ELECTRICAL
INLETS (Above
Refrigerant Lines)
AA INLET AIR BB
9−1/8
OUTDOOR FAN
(232)
GUARDS (2)
6−1/2
(165)
CENTER OF
LIQUID GRAVITY
3−3/4 LINES
(95)
INLET AIR
1−1/8 SUCTION
(29) LINES
EE
5 FF
1−1/8
(127) (29)
3−5/8
(92)
CC
SINGLE STAGE STAGE 1 STAGE 2 DD
TSA120S4S TSA120S4D TSA120S4D ELECTRICAL INLET AIR
TSA150S4D TSA150S4D INLETS (Above
Refrigerant Lines)
REFRIGERANT LINE
TOP VIEW
CONNECTIONS DETAIL
57-7/8 41-3/8 12
(1470) OPTIONAL HAIL GUARD (1051) (305)
(Field Installed All Coil Sides)
DISCHARGE (Not used with Coil Guard) DISCHARGE 2(51)
AIR AIR
COMPRESSOR CONTROL
BOX ACCESS 48-3/4
(1238)
REFRIGERANT
LINE CONNECTIONS
SEE DETAIL 45-1/4
(1149)
ELECTRICAL
INLETS (Above
Refrigerant Lines)
3-1/2
FORKLIFT SLOTS LIFTING HOLES (89)
(Both Sides) (For Rigging) OPTIONAL
COIL GUARD
60-1/8 BASE 43-5/8 BASE (Field Installed
(1527) (1108) All Coil Sides)
FRONT VIEW SIDE VIEW (Not used with
Hail Guard)
OPTIONAL
HAIL GUARD
(Field Installed
All Coil Sides)
(Not used with
Coil Guard)
9−1/8 OUTDOOR FAN
LIQUID INLET
(232) LINE (2) GUARDS (4)
AA AIR BB
6−1/2 SUCTION
(165) LINE (2)
3−3/4
(95)
1−1/8 CENTER OF
(29) GRAVITY
INLET
AIR
5 1−1/8 FF
(127) (29)
EE
3−5/8
(92)
DD CC
STAGE 1 STAGE 2 INLET
ELECTRICAL AIR
REFRIGERANT LINE INLETS (Above
CONNECTIONS DETAIL Refrigerant Lines) TOP VIEW
OPTIONAL
HAIL GUARD
57-7/8 (Field Installed 86-1/2 12
(1470) All Coil Sides) (2197) (305)
DISCHARGE (Not used with DISCHARGE 2(51)
AIR Coil Guard) AIR
COMPRESSOR 48-3/4
REFRIGERANT (1238)
CONTROL LINE CONNECTIONS 45-1/4
BOX ACCESS SEE DETAIL (1149)
ELECTRICAL
INLETS (Above
LIFTING HOLES Refrigerant Lines) FORKLIFT SLOTS
(Both Sides) 3-1/2
(For Rigging)
60-1/8 BASE 88-3/4 BASE (89)
(1527) (2254)
FRONT VIEW SIDE VIEW OPTIONAL
COIL GUARD
(Field Installed All Coil Sides)
(Not used with Hail Guard)
AIR HANDLERS
COOLING CAPACITY − TSA072S4S with [CBX27UH−060]
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
1920 905 69.1 20.3 4.83 .68 .83 .98 66.2 19.4 5.37 .70 .86 1.00 62.8 18.4 5.97 .71 .89 1.00 59.1 17.3 6.66 .74 .93 1.00
63_F 2400 1135 72.6 21.3 4.86 .73 .91 1.00 69.5 20.4 5.40 .75 .94 1.00 66.2 19.4 6.00 .77 .97 1.00 62.4 18.3 6.69 .80 1.00 1.00
(17_C)
2880 1360 75.7 22.2 4.87 .78 .97 1.00 72.6 21.3 5.42 .80 1.00 1.00 68.9 20.2 6.01 .84 1.00 1.00 65.3 19.1 6.71 .88 1.00 1.00
1920 905 72.7 21.3 4.86 .55 .66 .79 69.7 20.4 5.39 .55 .67 .81 66.1 19.4 5.99 .56 .69 .84 62.3 18.3 6.69 .57 .71 .88
67_F 2400 1135 76.3 22.4 4.88 .57 .70 .87 72.9 21.4 5.41 .58 .72 .90 69.2 20.3 6.03 .59 .75 .93 65.0 19.0 6.71 .61 .78 .97
(19_C)
2880 1360 79.0 23.2 4.90 .60 .75 .94 75.4 22.1 5.43 .61 .78 .97 71.5 21.0 6.04 .62 .81 1.00 67.2 19.7 6.74 .64 .85 1.00
1920 905 76.3 22.4 4.88 .41 .53 .64 73.0 21.4 5.42 .42 .54 .65 69.5 20.4 6.02 .42 .55 .67 65.4 19.2 6.71 .42 .56 .69
71_F 2400 1135 80.0 23.4 4.90 .42 .56 .68 76.4 22.4 5.44 .43 .57 .70 72.7 21.3 6.05 .44 .58 .72 68.3 20.0 6.74 .44 .60 .75
(22_C)
2880 1360 82.7 24.2 4.91 .44 .59 .73 79.1 23.2 5.46 .44 .60 .75 75.0 22.0 6.07 .45 .61 .78 70.5 20.7 6.77 .46 .63 .82
AIR HANDLERS
COOLING CAPACITY − TSA090S4S with [TAA090S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb CapacityMotor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
2400 1135 88.5 25.9 5.78 .68 .82 .97 84.7 24.8 6.40 .69 .84 .99 80.6 23.6 7.13 .71 .87 1.00 76.1 22.3 7.95 .73 .90 1.00
63_F 3000 1415 92.7 27.2 5.86 .73 .90 1.00 88.5 25.9 6.48 .75 .93 1.00 84.0 24.6 7.20 .77 .96 1.00 79.1 23.2 8.02 .79 .99 1.00
(17_C)
3600 1700 95.8 28.1 5.91 .79 .97 1.00 91.3 26.8 6.54 .80 .99 1.00 87.0 25.5 7.26 .83 1.00 1.00 82.5 24.2 8.10 .86 1.00 1.00
2400 1135 93.5 27.4 5.87 .54 .65 .78 89.6 26.3 6.50 .54 .67 .80 85.3 25.0 7.22 .56 .69 .83 80.3 23.5 8.04 .57 .70 .86
67_F 3000 1415 97.5 28.6 5.95 .57 .70 .86 93.4 27.4 6.58 .58 .72 .89 88.6 26.0 7.29 .59 .74 .92 83.3 24.4 8.11 .60 .77 .95
(19_C)
3600 1700 100.7 29.5 6.01 .60 .76 .94 95.8 28.1 6.63 .60 .78 .97 91.1 26.7 7.34 .62 .81 .99 85.8 25.1 8.16 .64 .84 1.00
2400 1135 98.5 28.9 5.97 .41 .52 .63 94.2 27.6 6.59 .42 .53 .65 89.8 26.3 7.32 .42 .54 .66 84.8 24.9 8.15 .42 .56 .68
71_F 3000 1415 102.7 30.1 6.04 .43 .55 .69 98.2 28.8 6.68 .43 .57 .70 93.3 27.3 7.39 .43 .58 .72 87.8 25.7 8.20 .44 .58 .74
(22_C)
3600 1700 105.8 31.0 6.10 .44 .59 .74 100.7 29.5 6.72 .44 .59 .75 95.6 28.0 7.44 .45 .61 .78 90.2 26.4 8.26 .45 .63 .81
AIR HANDLERS
COOLING CAPACITY − TSA120S4S with [TAA120S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 85_F (29_C) 95_F (35_C) 105_F (41_C) 115_F (46_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
3200 1510 113.3 33.2 7.09 .71 .86 .99 108.4 31.8 7.90 .73 .88 1.00 103.1 30.2 8.82 .74 .90 1.00 97.4 28.5 9.86 .76 .93 1.00
63_F 4000 1890 118.5 34.7 7.18 .77 .94 1.00 113.2 33.2 7.99 .79 .96 1.00 107.6 31.5 8.90 .81 .99 1.00 101.6 29.8 9.93 .83 1.00 1.00
(17_C)
4800 2265 122.2 35.8 7.25 .82 1.00 1.00 117.2 34.3 8.06 .84 1.00 1.00 112.3 32.9 8.98 .87 1.00 1.00 106.6 31.2 10.03 .90 1.00 1.00
3200 1510 120.0 35.2 7.21 .56 .69 .82 114.8 33.6 8.01 .58 .70 .84 109.3 32.0 8.93 .58 .72 .87 102.9 30.2 9.96 .59 .74 .90
67_F 4000 1890 124.8 36.6 7.30 .60 .75 .91 119.5 35.0 8.10 .60 .76 .93 113.3 33.2 9.00 .62 .78 .96 106.6 31.2 10.03 .63 .81 .99
(19_C)
4800 2265 128.5 37.7 7.37 .63 .80 .98 122.3 35.8 8.16 .64 .82 1.00 116.2 34.1 9.06 .65 .84 1.00 109.3 32.0 10.07 .67 .88 1.00
3200 1510 126.2 37.0 7.33 .43 .55 .67 121.1 35.5 8.13 .43 .56 .68 114.9 33.7 9.03 .43 .57 .70 108.5 31.8 10.06 .44 .58 .71
71_F 4000 1890 131.3 38.5 7.42 .44 .58 .72 125.6 36.8 8.23 .44 .59 .74 119.6 35.1 9.12 .45 .61 .76 112.5 33.0 10.13 .46 .62 .79
(22_C)
4800 2265 135.0 39.6 7.51 .45 .62 .78 128.9 37.8 8.29 .46 .63 .80 122.5 35.9 9.18 .46 .64 .82 115.2 33.8 10.19 .47 .67 .86
AIR HANDLERS
COOLING CAPACITY − TSA120S4D (FIRST STAGE) with [TAA120S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 65_F (18_C) 75_F (24_C) 85_F (29_C) 95_F (35_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb CapacityMotor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
3200 1510 61.7 18.1 2.72 .65 .78 .94 59.4 17.4 3.08 .66 .80 .96 56.8 16.6 3.49 .67 .82 .99 54.2 15.9 3.95 .68 .85 1.00
63_F 4000 1890 64.7 19.0 2.76 .69 .87 1.00 62.1 18.2 3.11 .70 .89 1.00 59.4 17.4 3.52 .72 .92 1.00 56.6 16.6 3.97 .74 .95 1.00
(17_C)
4800 2265 66.9 19.6 2.79 .74 .95 1.00 64.3 18.8 3.14 .76 .97 1.00 61.6 18.1 3.55 .78 .99 1.00 58.7 17.2 4.01 .81 1.00 1.00
3200 1510 65.3 19.1 2.77 .52 .62 .74 62.8 18.4 3.12 .52 .63 .75 60.2 17.6 3.53 .53 .64 .78 57.5 16.9 3.99 .54 .66 .80
67_F 4000 1890 68.5 20.1 2.80 .54 .67 .82 65.7 19.3 3.16 .55 .68 .84 62.8 18.4 3.56 .55 .69 .87 59.9 17.6 4.03 .57 .71 .91
(19_C)
4800 2265 70.6 20.7 2.83 .56 .71 .91 67.8 19.9 3.19 .57 .73 .93 64.8 19.0 3.59 .59 .76 .96 61.6 18.1 4.04 .59 .78 .99
3200 1510 68.9 20.2 2.81 .40 .50 .60 66.3 19.4 3.17 .40 .51 .61 63.5 18.6 3.57 .40 .51 .62 60.7 17.8 4.04 .40 .52 .64
71_F 4000 1890 72.2 21.2 2.84 .41 .53 .65 69.3 20.3 3.21 .41 .54 .66 66.2 19.4 3.61 .41 .54 .67 63.2 18.5 4.07 .41 .56 .69
(22_C)
4800 2265 74.4 21.8 2.87 .41 .55 .69 71.5 21.0 3.24 .42 .56 .71 68.3 20.0 3.64 .42 .58 .73 65.0 19.0 4.10 .43 .59 .75
AIR HANDLERS
COOLING CAPACITY − TSA150S4D (FIRST STAGE) with [TAA120S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 65_F (18_C) 75_F (24_C) 85_F (29_C) 95_F (35_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb CapacityMotor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
3200 1510 72.0 21.1 3.62 .65 .76 .89 69.5 20.4 4.04 .65 .77 .91 66.7 19.5 4.49 .66 .79 .93 63.8 18.7 5.01 .67 .81 .95
63_F 4000 1890 76.0 22.3 3.63 .68 .82 .97 73.3 21.5 4.05 .69 .84 .98 70.4 20.6 4.50 .70 .86 1.00 67.1 19.7 5.01 .72 .88 1.00
(17_C)
4800 2265 78.9 23.1 3.65 .72 .89 1.00 76.0 22.3 4.06 .73 .91 1.00 73.1 21.4 4.51 .75 .93 1.00 69.6 20.4 5.02 .77 .96 1.00
3200 1510 76.4 22.4 3.63 .52 .62 .72 73.9 21.7 4.05 .52 .63 .74 71.0 20.8 4.51 .53 .64 .75 67.8 19.9 5.01 .53 .64 .77
67_F 4000 1890 80.5 23.6 3.65 .54 .65 .78 77.8 22.8 4.06 .55 .66 .80 74.6 21.9 4.51 .55 .67 .82 71.4 20.9 5.02 .56 .69 .84
(19_C)
4800 2265 83.5 24.5 3.66 .56 .69 .85 80.8 23.7 4.07 .57 .71 .86 77.7 22.8 4.52 .57 .72 .89 73.9 21.7 5.02 .58 .74 .91
3200 1510 80.6 23.6 3.65 .40 .50 .60 78.1 22.9 4.06 .41 .51 .60 75.3 22.1 4.52 .41 .51 .61 72.0 21.1 5.02 .41 .52 .62
71_F 4000 1890 85.1 24.9 3.67 .42 .52 .63 82.2 24.1 4.07 .41 .53 .64 79.1 23.2 4.53 .42 .54 .65 75.6 22.2 5.03 .42 .54 .66
(22_C)
4800 2265 88.2 25.8 3.68 .42 .54 .67 85.3 25.0 4.08 .42 .55 .68 81.9 24.0 4.53 .42 .56 .70 78.2 22.9 5.04 .43 .57 .71
AIR HANDLERS
COOLING CAPACITY − TSA150S4D (FIRST STAGE) with [TAA180S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 65_F (18_C) 75_F (24_C) 85_F (29_C) 95_F (35_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb CapacityMotor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
4000 1890 75.3 22.1 3.63 .68 .81 .96 72.8 21.3 4.05 .69 .83 .98 69.9 20.5 4.50 .70 .85 1.00 66.7 19.5 5.01 .71 .87 1.00
63_F 5000 2360 79.0 23.2 3.64 .72 .89 1.00 76.3 22.4 4.06 .73 .91 1.00 73.1 21.4 4.51 .75 .94 1.00 69.7 20.4 5.01 .77 .96 1.00
(17_C)
6000 2830 81.9 24.0 3.65 .77 .96 1.00 79.2 23.2 4.07 .78 .98 1.00 75.8 22.2 4.52 .81 1.00 1.00 72.6 21.3 5.02 .83 1.00 1.00
4000 1890 79.5 23.3 3.64 .54 .65 .77 76.9 22.5 4.06 .54 .66 .79 73.9 21.7 4.52 .55 .68 .81 70.7 20.7 5.02 .56 .69 .83
67_F 5000 2360 83.5 24.5 3.66 .56 .70 .85 80.7 23.7 4.07 .57 .71 .87 77.5 22.7 4.52 .58 .72 .89 73.8 21.6 5.02 .59 .74 .92
(19_C)
6000 2830 86.4 25.3 3.67 .59 .74 .92 83.3 24.4 4.07 .60 .76 .94 80.0 23.4 4.53 .61 .78 .97 76.1 22.3 5.03 .62 .80 .99
4000 1890 83.8 24.6 3.66 .41 .52 .63 81.0 23.7 4.07 .41 .53 .64 77.9 22.8 4.52 .42 .54 .65 74.5 21.8 5.03 .42 .54 .66
71_F 5000 2360 87.9 25.8 3.68 .42 .55 .67 85.0 24.9 4.08 .43 .56 .69 81.7 23.9 4.54 .43 .57 .70 78.0 22.9 5.03 .43 .58 .72
(22_C)
6000 2830 91.0 26.7 3.69 .43 .58 .72 87.7 25.7 4.09 .43 .59 .73 84.3 24.7 4.54 .44 .60 .75 80.5 23.6 5.05 .45 .61 .77
AIR HANDLERS
COOLING CAPACITY − TSA180S4D (FIRST STAGE) with [TAA180S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 65_F (18_C) 75_F (24_C) 85_F (29_C) 95_F (35_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
4800 2265 93.8 27.5 4.63 .70 .82 .94 90.7 26.6 5.14 .71 .83 .95 87.1 25.5 5.70 .72 .85 .97 83.3 24.4 6.33 .73 .87 .99
63_F 6000 2830 98.3 28.8 4.69 .74 .88 1.00 95.0 27.8 5.20 .75 .90 1.00 91.3 26.8 5.76 .76 .91 1.00 87.1 25.5 6.39 .78 .94 1.00
(17_C)
7200 3400 101.7 29.8 4.75 .78 .94 1.00 98.1 28.8 5.25 .79 .95 1.00 94.2 27.6 5.80 .81 .97 1.00 90.0 26.4 6.43 .83 .99 1.00
4800 2265 98.7 28.9 4.70 .56 .68 .79 95.4 28.0 5.21 .57 .69 .80 91.9 26.9 5.77 .57 .70 .82 88.0 25.8 6.40 .58 .71 .83
67_F 6000 2830 103.6 30.4 4.77 .59 .72 .85 99.9 29.3 5.27 .59 .73 .86 96.0 28.1 5.83 .60 .74 .88 91.7 26.9 6.46 .61 .76 .90
(19_C)
7200 3400 106.9 31.3 4.83 .61 .76 .91 103.1 30.2 5.32 .62 .77 .92 99.1 29.0 5.88 .63 .79 .94 94.5 27.7 6.51 .64 .81 .96
4800 2265 103.4 30.3 4.77 .44 .55 .65 100.0 29.3 5.28 .44 .55 .66 96.3 28.2 5.84 .44 .56 .67 92.3 27.1 6.47 .44 .56 .69
71_F 6000 2830 108.5 31.8 4.85 .44 .57 .70 104.8 30.7 5.35 .44 .58 .71 100.7 29.5 5.91 .45 .59 .72 96.3 28.2 6.53 .45 .60 .74
(22_C)
7200 3400 112.0 32.8 4.91 .46 .60 .74 108.2 31.7 5.40 .46 .61 .75 103.8 30.4 5.96 .46 .62 .77 99.3 29.1 6.58 .47 .63 .79
AIR HANDLERS
COOLING CAPACITY − TSA240S4D (FIRST STAGE) with [TAA240S4D]
Outdoor Air Temperature Entering Outdoor Coil
Total 65_F (18_C) 75_F (24_C) 85_F (29_C) 95_F (35_C)
Entering Air
Wet Bulb Volume Total Sensible To Total Total Sensible To Total Total Sensible To Total Total Sensible To Total
Tempera- Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T) Cooling Comp Ratio (S/T)
ture Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb Capacity Motor Dry Bulb
kW kW kW kW
cfm L/s kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input
75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
kBtuh kW Input 75_F 80_F 85_F
24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C
6400 3020 124.8 36.6 5.92 .72 .84 .95 120.3 35.3 6.61 .73 .85 .97 115.7 33.9 7.37 .74 .87 .98 110.8 32.5 8.25 .75 .89 1.00
63_F 8000 3775 130.7 38.3 6.02 .76 .90 1.00 125.9 36.9 6.70 .77 .92 1.00 121.0 35.5 7.46 .79 .93 1.00 115.6 33.9 8.33 .80 .96 1.00
(17_C)
9600 4530 135.1 39.6 6.09 .81 .96 1.00 129.9 38.1 6.75 .82 .97 1.00 124.9 36.6 7.52 .84 .99 1.00 119.4 35.0 8.39 .86 1.00 1.00
6400 3020 132.3 38.8 6.03 .57 .70 .81 127.4 37.3 6.72 .58 .70 .82 122.6 35.9 7.48 .59 .72 .84 117.3 34.4 8.36 .59 .73 .85
67_F 8000 3775 138.2 40.5 6.14 .60 .74 .87 133.1 39.0 6.81 .61 .75 .88 128.1 37.5 7.58 .61 .77 .90 122.4 35.9 8.44 .62 .79 .93
(19_C)
9600 4530 142.9 41.9 6.22 .63 .79 .93 137.6 40.3 6.89 .63 .80 .95 132.0 38.7 7.64 .65 .82 .96 125.9 36.9 8.50 .66 .84 .98
6400 3020 139.3 40.8 6.16 .44 .56 .67 134.2 39.3 6.83 .45 .56 .68 129.0 37.8 7.59 .45 .57 .69 123.4 36.2 8.46 .45 .58 .70
71_F 8000 3775 145.4 42.6 6.26 .45 .58 .72 140.2 41.1 6.93 .46 .59 .73 134.7 39.5 7.69 .46 .60 .74 129.0 37.8 8.56 .46 .62 .76
(22_C)
9600 4530 150.2 44.0 6.34 .46 .61 .76 144.5 42.3 7.01 .46 .62 .78 138.6 40.6 7.75 .46 .63 .80 132.4 38.8 8.62 .47 .65 .81
This Specification is for Lennox Industries T−Classt, 6 to 20 Ton, outdoor air conditioner split system
(TS series) units. Revise specification section number and title below to suit project requirements,
specification practices and section content. Refer to CSI MasterFormat for other section numbers and
titles.
Optional text or text requiring a decision is indicated by bold brackets [ ]; delete text not required in final
copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of
specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols
are not used in specification text. Metric conversion, where used, is soft metric conversion.
SECTION 23 63 00
REFRIGERANT CONDENSERS
PART 1 GENERAL
1.01 SUMMARY
A. Section Includes: Split System Condensing Units.
Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI
MasterFormat and specifier’s practice.
B. Related Sections
Specifier Note: Article below may be omitted when specifying manufacturer’s proprietary products and
recommended installation. Retain Reference Article when specifying products and installation by an industry
reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name,
acronym, standard designation and title. Establish policy for indicating edition date of standard referenced.
Conditions of the Contract or Division 1 References Section may establish the edition date of standards. This
article does not require compliance with standard, but is merely a listing of references used. Article below
should list only those industry standards referenced in this section. Retain only those reference standards to
be used within the text of this Section. Add and delete as required for specific project.
1.02 REFERENCES
A. Air−Conditioning and Refrigeration Institute (ARI):
1. ARI 270−95 Sound Rating of Outdoor Unitary Equipment.
2. ARI 340/360 Commercial and Industrial Unitary Air−Conditioning and Heat Pump Equipment (ANSI
approved)
B. Servicing Standards:
1. National Electric Code (NEC).
2. Underwriters Laboratories (UL).
3. Canadian Electric Code (CEC).
C. Units to be Department of Energy (DOE) rated
D. ISO 9001, units manufactured to quality standard
E. Meet Minimum EPACT 2005, and addendums, efficiency levels
Specifier Note: Article below should be restricted to statements describing design or performance requirements
and functional (not dimensional) tolerances of a complete system. Limit descriptions to composite and
operational properties required to link components of a system together and to interface with other systems.
Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor before, during or
after construction. Coordinate this article with Architect’s and Contractor’s duties and responsibilities in
Conditions of the Contract and Division 1 Submittal Procedures Section.
1.04 SUBMITTALS
A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal
Procedures.
TS 6 to 12.5 Ton R−410A Air Conditioners / Page 29
GUIDE SPECIFICATIONS
PART 2 PRODUCTS
Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance
characteristics, material standards and descriptions as applicable. Use of such phrases as or equal" or or
approved equal" or similar phrases may cause ambiguity in specifications. Such phrases require verification
(procedural, legal and regulatory) and assignment of responsibility for determining or equal" products.
PART 3 EXECUTION
3.01 MANUFACTURER’S INSTRUCTIONS
Specifier Note: Revise article below to suit project requirements and specifier’s practice.
A. Compliance: Comply with manufacturer’s written data, including product technical bulletins, product catalog
installation instructions and product carton installation instructions.
3.02 EXAMINATION
A. Site Verification of Conditions: Verify substrate conditions, which have been previously installed under other
sections, are acceptable for product installation in accordance with manufacturer’s instructions.
3.03 INSTALLATION
A. Install Condensing Units in accordance with manufacturers instructions and regulations of authorities having
jurisdiction.
END OF SECTION
Visit us at www.lennox.com
For the latest technical information,
www.lennoxcommercial.com
Contact us at 1−800−4−LENNOX
NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2009 Lennox Industries Inc.