Type: PMN No: Eco No: Date:: Ds200 Master Software / Idea PMN-16-004 16452

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Type: DS200 MASTER SOFTWARE / IDEA

PMN No: PMN-16-004 ECO No: 16452 Date: 01/08/2016

Previous Revision New Revision


CFC (DS200) CFD (DS200)
Product:
CAU build671 (IDEA) CAV build676 (IDEA)
Card: - -

REASON and DEFINITION of the MODIFICATION

DS200 series CPU4 software version has been updated to CFD

SOFTWARE THAT MUST BE USED WITH MASTER VERSION CFD:


IDEA : CAV (Build 676)
KNE : ACA

Important Notes:
 1/S2 PRI cards can now be used with CFC and CFD version master software. 1/S2
Card software should be updated to ADJ.

 With Master version CFD, PRI/R2 software version should be BEO or more recent
software.

 With Master version CFD, MGW3 software version AEA-02 should be used
 With Master version CFD, VRC200 version AEA-08 should be used.
 With Master version CFD, MGW3 should be used, MGW2 cannot be used.

With the CFD version:

 SIP_TRUNK version is updated to : AHF


 SIP_SPC version is updated to: AHA
 H323 version is updated to: ADA
 NKS version is updated to: ABA-02
 DS200L Environment is : ABG
 VRC200 version is updated to AEA-08
 MGW3 version is updated to AEC-02

Page No: 1/5


For CPU4 CFC to CFD update; Environment, jffs2 and master software should be
updated. After jffs2 update system IP address will return to it’s default value
(192.168.2.100). Environment update is not required for DS200L systems.

For DS200 CPU4:


Ramdisk : AAL
Environment : ABF
image.jffs2 : AAP
Kernel : AAD

For DS200S/M CPU4:


Ramdisk : AAI
Environment : ABE
image.jffs2 : AAJ
Kernel : AAD

CPU4 System Update

a) Download the system backup file to a pc with the latest idea. (CAV)

b) Before updating the software, the following steps should be carried out in
order

TFTP server, ramdisk, kernel, environment and repo.conf files are copied to the pc
that will be used for updating the software.

In Winspc/karel/home/conf/dsupdate.conf
The IP address which is in dsu_server must set the same as IP address which TFTP
server runs in.

Update procedure for CPU4

 Install the latest Idea program (CAV) and save system backup to PC.
 Connect the system with winscp, Erase the bicom.conf, firewall.conf,
snmp.conf files. (File location: “karel/home/conf/”)
 Open dsupdate.conf file under “karel/home/conf” folder.
 Set DSU_SERVER address as your PC’s IP.
 Copy the p_cfd_ugb.rpm file to “karel/bin” folder (Transfer files by Winscp)
 Copy TFTP folder structure to your PC desktop.
 Run TFTP.exe file. ( Depending on your CPU4 configuration select the folder :
ds200 or ds200s/m )
 Click windows start menu, select run and type CMD , Enter the following

Page No: 2/5


command on command window
 telnet -t vt100 xxx.xxx.xxx.xxx

where x part notates the ip address of CPU4

 Login : root
Password : ds200 or ds200s
 Enter the following commands

# telinit 4

# dsupdate rd

# dsupdate kernel

# dsupdate jffs2 (after updated this file, you need to change IP address of system
in "/flash/etc/sysconfig.conf". Because after updating this file, IP address will be
set as default IP: 192.168.2.100)

# dsupdate cf

# cd karel\bin

# dsinstall p_cfd_ugb.rpm

 Reboot the system.


 Delete the non-volatile memory
 Switch the system OFF/ON.
 Load the system backup file from the PC.

17. Write into the non-volatile memory.

IMPORTANT:

System Shut Down Procedure

 This procedure is required in order to minimize the risks of damaging the


Compact Flash Cards on CPU. Latest Kernel update is now suggested for all
Compact Flash cards. (This kernel software was released with previous CEB
software)

Page No: 3/5


1) Push the button on CPU card with sharp object (like a pen-point) for 20
seconds.

2) Then release the button and wait 45-60 seconds.(D1 green led near Altera chip
on CPU motherboard will be off)

3) Power off from SPS.

 Important Points: System should not be powered off manually during boot
process of CPU!!!

Sometimes the system startup is delayed due to the check disk procedure for
fixing file structure errors during boot. However customer may try to restart or
power off the system from SPS at this point. This is the most common fault for CF
related problems.

At this point CPU led indication Red Continious ON

Green ON.

 This procedure must be followed by next reboot (even if the system is restarted
by a power failure.)

To check the version of Kernel software; Below procedure should be followed.

During Winscp connection enter the below command.

getconf

Operating System
----------------
Linux 2.4.25 #248 Mon May 4 17:01:57 EEST 2015 (DS200/S/M systems)

Operating System
----------------
Linux 2.4.25 #300 Tue Apr 21 10:23:08 EEST 2015 (DS200 system)

Above versions should be checked after entering the command. System


restart is required after the kernel update.

Page No: 4/5


Note: For CFD software Log Messages – KTS parameter should not be selected as All
(Detailed) on IDEA SYSTEM PARAMETERS! Otherwise system stability can be affected.
This problem will be fixed with new software.

Improvements

 Regarding CPU4 Integrated IVR a stuttering problem is observed during


greeting message for some systems, this problem is fixed with ENV. Update

 Operator was unable to transfer incoming external calls to the E&M lines. This
problem is now fixed.

 The line hanging problem is fixed for the below scenario.

DS200 system is connected with MS48 over IP trunk.


Incoming external call lands on DS200 operator, Operator uses “blind transfer”
and transfers the call to MS system. Rarely both IP Trunk and Analog Trunk were
hanged. This problem is now fixed.

 Extension with name information was unable to make a call through PRI/Qsig
lines. This problem is now fixed.

 A system reset problem was detected during a scenario containing


conference room initiation/ joining. This problem is now fixed.

 IDEA LCR Leading Digits table row number is extended from 128 to 512.

Th