H Generator Set Data Sheet
H Generator Set Data Sheet
H Generator Set Data Sheet
Frequency: 60
Fuel type: Diesel
KW rating: 1750 standby
1600 prime
Emissions level: EPA NSPS Stationary Emergency Tier 2
Fuel flow
Maximum fuel flow, L/hr (US gph) 946 (250)
Maximum fuel inlet restriction, kPa (in Hg) 30 (9.0)
Maximum fuel inlet temperature, °C (°F) 71 (160)
©2010 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
“Our energy working for you.” is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
D-3335i (7/10)
Standby Prime Continuous
Air rating rating rating
3
Combustion air, m /min (scfm) 156 (5563) 143 (5097)
Maximum air cleaner restriction, kPa (in H2O) 6.2 (25)
3
Alternator cooling air, m /min (cfm) 204 (7300)
Exhaust
3
Exhaust flow at set rated load, m /min (cfm) 379 (13518) 347 (12400)
Exhaust temperature, °C (°F) 469 (877) 463 (866)
Maximum back pressure, kPa (in H2O) 6.8 (27)
Weights2
Unit dry weight kgs (lbs) 14628 (32249)
Unit wet weight kgs (lbs) 15155 (33410)
Notes:
1
For non-standard remote installations contact your local Cummins Power Generation representative.
2
Weights represent a set with standard features. See outline drawing for weights of other configurations.
Derating factors
Engine power available up to 1402 m (4600 ft) at ambient temperatures up to 40 °C (104 °F). Above these
Standby
elevations, derate at 4.5% per 305 m (1000 ft) and 11.0% per 10 °C (18 °F).
Engine power available up to 1402 m (4600 ft) at ambient temperatures up to 40 °C (104 °F). Above these
Prime
elevations, derate at 4.5% per 305 m (1000 ft) and 11.0% per 10 °C (18 °F).
Continuous
Ratings definitions
Emergency standby power Limited-time running power Prime power (PRP): Base load (continuous)
(ESP): (LTP): power (COP):
Applicable for supplying power Applicable for supplying power to Applicable for supplying power Applicable for supplying power
to varying electrical load for the a constant electrical load for to varying electrical load for continuously to a constant
duration of power interruption of limited hours. Limited Time unlimited hours. Prime Power electrical load for unlimited
a reliable utility source. Running Power (LTP) is in (PRP) is in accordance with ISO hours. Continuous Power (COP)
Emergency Standby Power (ESP) accordance with ISO 8528. 8528. Ten percent overload is in accordance with ISO 8528,
is in accordance with ISO 8528. capability is available in ISO 3046, AS 2789, DIN 6271
Fuel Stop power in accordance accordance with ISO 3046, and BS 5514.
with ISO 3046, AS 2789, DIN AS 2789, DIN 6271 and BS 5514.
6271 and BS 5514.
Notes:
1
Limited single phase capability is available from some three phase rated configurations. To obtain single phase rating, multipy the three phase
3
kW rating by the Single Phase Factor . All single phase ratings are at unity power factor.
2
Standby (S), Prime (P) and Continuous ratings (C).
3
Factor for the Single Phase Output from Three Phase Alternator formula listed below.
4
Maximum rated starting kVA that results in a minimum of 90% of rated sustained voltage during starting.
Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s electrical system
except through an approved device or after building main switch is open.