Because of their delivery rates and reservoir capacities these grease pump units are designed to supply small and mediumsize
systems. They come with 2 or 3 pump outlet ports.
The possible operating voltages are 90 to 264 V AC, 47 to 440 Hz, or 12 or 24 V DC.
Safety elements like pressurelimiting valves, overpressure indicators or rupture discs must be provided for in order to protect the
pump unit from overloads. Information on this point can also be found in leaflet 101076US, page 3 “Accessories”.
Quality Management
DIN EN ISO 9001: 2000
Environmental Management
DIN EN ISO 14001
Piston pumps with grease reservoir · progressive systems 101072US 2
Technical data
Unit
Model KFA1M
Operating voltage . . . . . . . . . . . . 24 V DC
Typ. power consumption . . . . . . 0.5 A at 24 V
at max. operating pressure and 20° C
Max. back pressure . . . . . . . . . . 300 bars
Mode/ON time . . . . . . . . . . . . . . S3 – 20 % – 50 minutes
Perm. operating temperature . . . – 25 °C to + 75 °C
Model KFA10
Operating voltage . . . . . . . . . . . . 115 V AC, 50 or 60 Hz
230 V AC, 50 or 60 Hz
Typ. power consumption . . . . . . 1 A at 115 V / 50 Hz
at max. operating pressure and 20 °C 1.3 A at 115 V / 60 Hz
0.45 A at 230 V / 50 Hz
0.66 A at 230 V / 60 Hz
The pump can be outfitted with a maximum of two pump Max. back pressure . . . . . . . . . . 300 bars
elements. Mode/ON time . . . . . . . . . . . . . . S3 – 10 % – 50 minutes
Versions for various operating voltage are available. Perm. operating temperature . . . 0 °C to + 40 °C
161210012 ± 20
6 Applicable protection measures for operation:
300 M14x1.5
161210016 10
– “Protective Extra Low Voltage” (PELV)
Standards: IEC 602041
Please indicate in addition to the order No.: IEC 60364441
operating voltage, – The unit has to be disconnected for insulation and voltage
quantity and order No. of pump elements tests to EN 602041:1992.
with pressurelimiting valve.
Order example
KFA1MW, 24 V DC
outfitted with pump element
outlet 1 – KFA1.U1
outlet 2 – KFA1.U3 Operating instructions for KFA and KFAS piston pumps:
and 2 pressurelimiting valves 161210012 951130185
Piston pumps with grease reservoir · progressive systems 101072US 3
line socket
(DIN EN 175301 803/ISO 4400)
rotatable 90°
Legend, model KFA1 Applicable protection measures for operation: Legend, model KFA10
“Protective Extra Low Voltage” (PELV)
L+ + potential, supply voltage Standards: IEC 602041 L1/N supply voltage
(main machine switch ON) IEC 60364441 (main machine switch ON)
M – potential, supply voltage PE protective earth conductor
(OV, GND) X1 plugin connection, supply voltage
X1 plugin connection, supply voltage X2 Color code Core color
X2 plugin connection, lubricantlevel switch
PIN abbreviations
X2 plugin connection, lubricantlevel switch WS lubricantlevel switch
WS lubricantlevel switch 1 BN brown contact illustration: full reservoir
Dimensions in mm
Technical data
Motor
Operating voltage . . . . . . . . . . . . 12 V DC / 24 V DC
Fuse . . . . . . . . . . . . . . . . . . . . . . 5 A / 3 A
Unit
Max. back pressure . . . . . . . . . . 300 bars
Perm. operating temperature . . . – 25 °C to + 75 °C
Type of enclosure DIN EN 60 529 . IP 55
Reservoir capacity . . . . . . . . . . . 2 or 6 kg
Reservoir material . . . . . . . . . . . . PA6i (2 kg reservoir)
. . . . . . . . . . . . . . . . . . . . . . . . . . PMMI (6 kg reservoir)
Number of outlet ports . . . . . . . . max. 3 (1.1, 1.2 and 1.3)
(If less than 3 outlet ports are needed, screw plugs are used
in place of pump elements.)
With lubricantlevel switch Reservoir capacity Please note: only use grease that has been approved by
Order No. Order No. [kg] Willy Vogel AG.
Approved lubricants list “Lubricants for Progressive Systems,
KFG15 KFG15W2M 2
NLGI grade 2”, see “www.vogelag.com” or
KFG35 KFG35W2M 6
please request from “info@vogelberlin.de”.
Please indicate in addition to the order No.:
Lubricantlevel switch
operating voltage, quantity and order No. of pump elements
Function:
(max. 3) with pressurelimiting valve.
Switch opens when lubricant drops to critical level.
Order example Fault also signaled in the event of a wire break.
Operating voltage . . . . . . . . . . . . 10 to 30 V DC
KFG15W2, 24 V DC
Switching frequency . . . . . . . . . . 100 Hz
outfitted with pump element
Continuous current . . . . . . . . . . . ≤ 200 mA
KFG1.U1 (left 1.1)
Natural current consumption . . . 6 to 12 mA
KFG1.U2 (middle 1.2)
Voltage drop . . . . . . . . . . . . . . . . ≤ 1.8 V at Icontinuous
KFG1.U3 (right 1.3)
EC directives. . . . . . . . . . . . . . . . EN 60 94752
and 3 pressurelimiting valves 161210012
Notice:
Pump elements
The installation's ambient surroundings and cable connections
Order No. Delivery rate 1) Connection have a decisive influence on the unit's electromagnetic compati
[cm3/min] thread bility. During the installation it is therefore necessary to assure
the EMC of the entire system.
KFG1.U0 6
KFG1.U1 2.5
Applicable protection measures for operation:
KFG1.U2 1.8 M14x1.5
KFG1.U3 1.3 – “Protective Extra Low Voltage” (PELV)
KFG1.U4 0.8 Standards: IEC 602041
IEC 60364441
11) Theindicated delivery rates refer to the delivery of NLGI grade 2 grease
at a temperature of +20 °C and a back pressure of 50 bars.
– The unit has to be disconnected for insulation and voltage
Temperatures and pressures that deviate therefrom will change the tests to EN 602041:1992.
delivery rate.
Take the indicated values as a basis when configuring a centralized
lubrication system.
Pressurelimiting valves
Order No. Opening pressure Connection Connection
[bars] thread for tube diam.
161210012 ± 20
6 Operating instructions for KFG and KFGS piston pumps:
300 M14x1.5
161210016 10 951130184
Piston pumps with grease reservoir · progressive systems 101072US 5
KFG15W2M
line socket
(DIN EN 175301 803/
ISO 4400)
rotatable 90°
cable connection:
+ to 2
– to 1
KFG35W2M
Piston pumps with reservoir, integral control unit – Models KFGS15(W2) / KFGS35(W2)
Technical data
KFGS15 Notice:
The installation's ambient surroundings and cable connections
have a decisive influence on the unit's electromagnetic compati
bility. During the installation it is therefore necessary to assure
with Reservoir the EMC of the entire system.
lubricantlevel switch capacity
Order No. Order No. [kg] Applicable protection measures for operation:
KFGS15 KFGS15W2 2 – “Protective Extra Low Voltage” (PELV)
KFGS35 KFGS35W2 6 Standards: IEC 602041
IEC 60364441
Please indicate in addition to order No.: – The unit has to be disconnected for insulation and voltage
operating voltage, quantity and order No. of pump elements tests to EN 602041:1992.
(max. 3) with pressurelimiting valve.
Operating instructions for KFG and KFGS piston pumps:
Order example 951130184
KFGS15W2, 24 V DC
outfitted with pump element
1 KFG1.U1 (left 1.1)
1 KFG1.U2 (middle 1.2)
1 KFG1.U3 (right 1.3)
and 3 pressurelimiting valves 161210012
KFGS15W2
filling via
cable harness
conical head nipple
connection
DIN 71 412 AM 10x1
KFGS35
filling via
cable harness
conical head nipple
connection
DIN 71 412 AM 10x1
Dimensions in mm
Piston pumps with reservoir, integral power pack – Models KFG105(W2) / KFG305(W2)
Technical data
KFG105W2
filling via
conical head nipple
DIN 71 412 AM 10x1
line socket
(DIN EN 175301 803/
ISO 4400)
rotatable 90°
KFG305W2
filling via
conical head nipple
DIN 71 412 AM 10x1
line socket
(DIN EN 175301 803/
ISO 4400)
rotatable 90°
Dimensions in mm
Piston pumps with reservoir, integral power pack and control unit – Models KFGS105(W1) / KFGS305(W1)
Technical data
Notice:
The installation's ambient surroundings and cable connections
have a decisive influence on the unit's electromagnetic compati
bility. During the installation it is therefore necessary to assure
the EMC of the entire system.
KFGS305 KFGS105
KFGS105 KFGS105W1 2
KFGS305 KFGS305W1 6
Order example
KFGS105W1
outfitted with pump element
1 KFG1.U1 (left 1.1)
1 KFG1.U2 (middle 1.2)
1 KFG1.U3 (right 1.3)
and 3 pressurelimiting valves 161210012
KFGS105W1
line socket
(DIN EN 175301803/
ISO 4400)
rotatable 90°
circular
connectors X4
plugin connection
filling via
to DIN EN 60947 /
conical head nipple
EC 947
DIN 71 412 AM 10x1
KFGS305W1
line socket
(DIN EN 175301803/
ISO 4400)
rotatable 90°
circular
connectors X4
plugin connection
to DIN EN 60947 /
EC 947 filling via
conical head nipple
DIN 71 412 AM 10x1
Dimensions in mm
Leaflet information
101071US Progressive Feeders
101074US Grease Pump Units (models PF, PFP, PFH)
140021US Motor Pump Unit GSJB
DSK 200800US Grease Pump Unit FF
DSK 200500US Grease Pump Unit FB
101075US Piston Pumps (Typ PPU, PHU)
101076US Accessories for Progressive Systems
Notice!
All products from VOGEL may be used only for their intended purpose.
If operating instructions are supplied together with the products, the provi
sions and information therein of specific relevance to the equipment must
be observed as well.
In particular, we call your attention to the fact that hazardous materials of
any kind, especially the materials classified as hazardous by EC Directive
67/548/EEC, Article 2, Par. 2, may only be filled into VOGEL centralized
lubrication systems and components and delivered and/or distributed with
the same after consultation with and written approval from VOGEL.
0000 01/2006
All products manufactured by VOGEL are not approved for use in con
junction with gases, liquefied gases, pressurized gases in solution and
fluids with a vapor pressure exceeding normal atmospheric pressure
(1013 mbars) by more than 0.5 bar at their maximum permissible
temperature.