Footing Schedule A
5'-0"
A

Type Footing Footing Footing Reinforcement


Size: Thickness
C1

4'-0"
Single Column
Footing 5'-0" x 4'-0" 10" + 3" = 13" 16mmØ bar 6" c/c both way
Double Column
Footing 6'-0" x 4'-0" 10" + 3" = 13" 16mmØ bar 6" c/c both way x
FOOTING LAYOUT

10"
Outside Existing Land Level
Outside Existing Land Level
12" x 12" Grade
4Nos 16 mm Ø rod
Beam 10mmØ tie bar 6" c/c
1'-0"
3'-11"

3'-11"
5'-0"

5'-0"
1'-0" 1'-0"

3"
3"

10"
10"

16 mm Ø rod 6" c/c


16 mm Ø rod 6" c/c

3"
3"

4'-0"
5'-0"
3" Brick Flat Soling

A-A Section Details X-X Section Details

Drawing & Design By:


Drawing Title: Boundary wall design drawing details
of Kalyar Replica Ltd. (Column & Footing Details)
Monayem Ahmed
Manager, Engineering
The ACME Laboratories Ltd.